Cross Connection Hazard Assessment

Open Solicitation Posted

Solicitation number
SP330027Q0011
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Tracy, California 95304, United States

Notice details come from SAM.gov. Updated .

About this opportunity

Defense Logistics Agency Distribution seeks a cross connection hazard assessment of the potable water system at DLA Distribution San Joaquin, Tracy, California, under a Total Small Business set-aside, with quotations due November 23, 2026. The solicitation is SP3300-27-Q-0011, a Request for Quotation under NAICS 541380, Testing Laboratories and Services, with a $19 million size standard and PSC F107, Environmental Systems Protection, Toxic and Hazardous Substance Analysis.

Work is performed on-site at DLA Distribution San Joaquin Base Supply, 25600 S Christman Road, BOSS WHSE 29-5, Tracy, California 95304. The period of performance runs December 1, 2026 through May 31, 2027, with anticipated award on December 1, 2026. The single CLIN (0001) requires a firm fixed unit price for 92,500 months of hazardous substance analysis.

The contractor must baseline the installation's potable water system, including one groundwater source, on-site pumping and treatment facilities, an elevated storage tank, the campus distribution system, and 43 served buildings. Hazards are classified High or Low under the Uniform Plumbing Code and military public health guidelines, with corrective actions such as Reduced Pressure Zone assemblies or Double Check Valves. All personnel must hold current, valid certifications as Cross-Connection Control Specialists or Backflow Prevention Assembly Testers from recognized authorities such as AWWA or USC's Foundation for Cross-Connection Control and Hydraulic Research. On-site contractors require installation passes, vehicle registrations, identification badges, and OPSEC training.

Deliverables include an Excel inventory database, a Draft Assessment Report subject to a 15 business-day Government comment period, and a Final Assessment Report with an executive summary, photographic documentation of critical hazards, and a prioritized mitigation plan. Quoters submit three files: technical capability, past performance, and Attachment 1 pricing in the CLIN structure. All submissions require CUI markings. Evaluation rates Technical Capability and Past Performance acceptable or unacceptable, and award goes to the lowest-priced technically acceptable quoter. Quoters must be registered in SAM and provide their CAGE code and manufacturer information as applicable.

Notice text

Cross Connection Hazard Assessment for DLA Distribution San Joaquin, CA

Files

File Type Posted
SP330027Q0011.pdf PDF
Tab A-3 PWS_Cross_Connection_Haz_Assesment.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
H346--Legionella Water Testing United States · NAICS 541620 Veterans Integrated Service Network 22 Service-Disabled Veteran-Owned Small Business
Laboratory Analysis of Water Samples NAICS 541380 — Total Small Business
CA-SAN luis NWR-fire system rehab NAICS 238220 — Total Small Business
Water quality analysi Aviation No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors