Colorado Springs Airtanker Electrical Project
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 1240LT26Q0043
- Agency
-
Forest Service
Department of Agriculture
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- Colorado 80916, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The USDA Forest Service is soliciting quotations for the Colorado Springs Airtanker Base Electrical Project through Request for Quotation (RFQ) 1240LT26Q0043 to install weatherproof electrical power infrastructure at the loading pits of the Colorado Springs Airtanker Base. The project requires contractors to supply all labor, materials, equipment, and miscellaneous items necessary to install electrical service to support micromotion meters used for retardant loading on agency-contracted air tankers, with all work requiring compliance with applicable Federal, State, and Local codes including Davis-Bacon prevailing wage requirements. Key requirements include installation of a 100-amp three-phase power panel (NEMA 3R or equivalent), a 30KVA NEMA 3R transformer, weatherproof conduit, and two double 110, 15-amp plugs with detachable weatherproof conduit at Pit 1, with an optional identical installation at Pit 2 located approximately 250 feet away. Evaluation will be based on technical approach—assessed through a contractor confidence rating for sound, compliant execution with a detailed 1-3 page narrative and construction schedule—and price. Critical deadlines include April 2, 2026, at 1:00 p.m. CDT for submission of questions to the Contract Specialist and Contracting Officer, and April 22, 2026, at 1:00 p.m. CDT for quote submission via email.
This solicitation is designated as a Total Small Business Set-Aside, with no current incumbents identified in the notice; however, four companies attended the mandatory site visit on March 26, 2026: Freedom Mechanical, Green Electric, Atmosphere LLC, and Foster Electric. The estimated contract value falls between $25,000 and $100,000, classified under NAICS code 238210 (Electrical Contractors) with a small business size standard of $19 million, and bidders must provide a 20% bid guarantee, with additional performance and payment bonds required depending on award amount. The period of performance runs from May 1, 2026, through October 30, 2026, with the contractor required to complete all work by August 30, 2026. Work will be performed at the Colorado Springs Airtanker Base (3475 Bud Breckner Boulevard, Colorado Springs, Colorado 80916), located in a secure area of Colorado Springs Airport where contractor personnel must obtain USFS access authorization and comply with all airport rules and regulations. Work hours are available seven days a week from 0800 to 1800 hours, and the contractor is responsible for daily travel reimbursement and personnel staffing levels commensurate with project scope.
Notice text
2 versions
Update #2 · Latest ·
Amendment 0001 - To provide Question and Answers and Site Visit Atendee list. See 1240LT26Q0043_A0001_S for full details.
Solicitation 1240LT26Q0043 is issued as a Request for Quotation (RFQ) for supplying all labor, materials, equipment and miscellaneous items for the purpose of installing electrical power to the loading pit(s) at the Colorado Springs Airtanker Base. Electrical power is needed for micro motions meters which are required by policy for the loading of retardant on the agency contracted air tankers and all electrical work needs to be weatherproof due to outdoor exposure. Refer to the Statement of work for the full electrical project requirements. See the attached Solicitation and applicable documents for full project details and requirements.
NOTE: A site Visit will be held on March 26th, 2026. Refer to Solicitation for details and requirements.
Update #1 ·
Solicitation 1240LT26Q0043 is issued as a Request for Quotation (RFQ) for supplying all labor, materials, equipment and miscellaneous items for the purpose of installing electrical power to the loading pit(s) at the Colorado Springs Airtanker Base. Electrical power is needed for micro motions meters which are required by policy for the loading of retardant on the agency contracted air tankers and all electrical work needs to be weatherproof due to outdoor exposure. Refer to the Statement of work for the full electrical project requirements. See the attached Solicitation and applicable documents for full project details and requirements.
NOTE: A site Visit will be held on March 26th, 2026. Refer to Solicitation for details and requirements.
Files
| File | Type | Posted |
|---|---|---|
| 1240LT26Q0043_A0001_S.pdf | ||
| 1240LT26Q0043_Final.pdf | ||
| Attachment 1_SOW_COS Airtanker Base.pdf | ||
| Attachment 2_SOI_COS Air Tanker Electrical Project HH.xlsx | XLSX spreadsheet | |
| Attachment 3_Wage Determination.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Colorado Springs Airtanker Electrical Project | Award Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Fernan Ranger Station lift station electrical repair | Region 1 - Northern Region | Total Small Business | |
| Barillas Peak & Encino Vista Lookout Tower Restoration, Santa Fe NF | Forest Service | Total Small Business | |
| Loleta Water System Upgrades | Forest Service | Total Small Business | |
| Administrative Parking Lot Repairs | Forest Service | Total Small Business | |
| ID-KOOSKIA NFH-Repair Electrical Service to Mechan | — | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity