Cacl - replace sewage pumps
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 140P4526R0032
- Agency
-
Northeast Region
National Park Service, Department of the Interior
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Interior National Park Service Northeast Region seeks replacement of sewage pumps and control systems at Castle Clinton National Monument, with proposals due August 24 at 1200 EST and questions due August 19. This is a Total Small Business Set-Aside with a project magnitude between $100,000 and $250,000.
Place of performance is Battery Park, Manhattan, New York. The contractor must remove and replace two existing submersible sewage ejector pumps, repair or replace the float control system and associated electrical components, and replace approximately 20 linear feet of electrical wiring between pumps and control panel. All electrical work must comply with applicable codes. The contractor must field-verify existing site conditions prior to procurement and submit detailed pump specifications for NPS approval, including manufacturer certification curves, proposed operating points, motor specifications, and compatibility documentation with the existing duplex pumping system. Confined-space entry procedures apply. Work is limited to weekday hours of 7:00 AM to 5:00 PM unless approved otherwise. Wage rate requirements apply. NAICS code is 238220, Plumbing, Heating, and Air-Conditioning Contractors, with size standard $19 million.
Performance runs September 3 through October 7, 2026. The contractor must begin within 10 calendar days of notice to proceed and complete work within 30 calendar days. Performance and payment bonds are required within 10 calendar days of award. A mandatory site visit is scheduled for August 14 at 10:00 AM EST. Proposals must include a technical narrative (maximum 10 pages), prior experience documentation (maximum 5 projects from past 5 years), past performance references (up to 3 projects from past 3 years), and detailed price schedule. Award is based on best value, evaluated on technical approach, experience, past performance, and price. Offerors must be registered in SAM with current NAICS 238220 representation at proposal submission. Amendment 0001 (effective August 19) added questions and answers and revised the Statement of Work; offerors must acknowledge receipt of this amendment.
Notice text
CACL - REPLACE SEWAGE PUMPS
Files
Notice history
| Notice | Type | Posted |
|---|---|---|
| Cacl - replace sewage pumps | Award Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| LAKE25-101-CC lift station pump repair | Pacific West Region | Total Small Business | |
| Fort Mifflin Sewage Lift Station | ENDIST Philadelphia | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity