The Defense Health Agency seeks quotes for a Micromedical by Interacoustics Visual Eyes 525 3rd Generation VNG System and related vestibular diagnostic equipment, with quotes due September 8 at 10:00 AM Pacific and questions due September 1 at 10:00 AM Pacific. This is a 100% Service-Disabled Veteran-Owned Small Business set-aside under simplified acquisition procedures.

Place of performance is Naval Medical Center San Diego, 2051 Cushing Road, Building 624, San Diego, California 92106. The procurement requires delivery of 13 contract line items including the primary VNG system, Air Fx 110V caloric irrigator, Aqua Stim 110V device, 75-inch monitor for oculomotor testing, OtoAccess Database Single License Code, VisualEyes SFF Printer Kit, one-year manufacturer warranties, installation services, and shipping, all within a single shipment within 90 days after receipt of order. Equipment must comply with IEC60601-1-2:2014 emission class B group 1 standards and deliver water flow rate of 250ml/30 seconds with 15ml accuracy. Installation occurs post-delivery during normal working hours (07:30–16:30, Monday through Friday, excluding federal holidays). Contractor personnel performing unboxing and installation are not required to hold DBIDS credentials prior to delivery; Naval Medical Center San Diego will sponsor temporary base access contingent upon receipt of required security vetting information 3–5 business days prior to installation. NAICS code is 339112 (Surgical and Medical Instrument Manufacturing); PSC code is 6515. Award will use Lowest Price Technically Acceptable procedures with no tradeoffs. Quoters must be original equipment manufacturers, authorized dealers, distributors, or resellers verified by OEM authorization letters. The Non-Manufacturer Rule does not apply because the acquisition value is at or below the Simplified Acquisition Threshold.

Notice text

2 versions

Update #2 · Latest ·

See Attached:

1. HT94102Q2079 CSS

2. Attachment 1 HT94102Q2079 SOW

3. HT94102Q2079 Question and Answers

Update #1 ·

See Attached:

1. HT94102Q2079 CSS

2. Attachment 1 HT94102Q2079 SOW

Files

File Type Posted
HT94102Q2079 Question and Answers.pdf PDF
Attachment 1 HT94102Q2079 SOW.pdf PDF
HT94102Q2079 CSS.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
6515--NX EQ Image Guided Surgical Navigation System (VA-26-00083972) Nationwide, United States · NAICS 334510 VA Strategic Acquisition Center Frederick Service-Disabled Veteran-Owned Small Business
Corneal Analyzer OPD-Scan III Wavefront Aberrometer California 94612, United States · NAICS 339115 Department of Veterans Affairs No set-aside
Zeiss Meditec Ophthalmology Equipment Maintenance Camp Lejeune, North Carolina 28547, United States · NAICS 811210 Defense Health Agency Total Small Business
Repair and Maintenance Service for Histology and Cytology Equipment San Diego, California, United States · NAICS 811210 Defense Health Agency Total Small Business
All in one visual acuity system Crownpoint, New Mexico 87313, United States · NAICS 339115 Indian Health Service Indian Small Business Economic Enterprise

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity