About this opportunity

The Department of the Air Force, Air Mobility Command, is seeking a contractor to furnish and install automatic door operators and handicap button access to existing doors at Buildings 528 and 940 on Little Rock Air Force Base. The contractor must provide all licensed and qualified personnel, transportation, tools, equipment, materials, and services required to complete the work. Specifically, the contractor shall install Allegion/Stanley Access 75" M-Force overhead door auto operators (or equal) and associated controls. Responses are due by July 8, 2024, and the estimated time of delivery is no later than 120 days after award. Award will be made to the responsible offeror whose proposal is most advantageous to the government.

This procurement is set aside for small businesses under NAICS code 332321 - Metal Window and Door Manufacturing. The place of performance is Little Rock Air Force Base, Arkansas. The contract will be awarded on a firm fixed-price basis, and the government has not provided an estimated value or budget range. No incumbent or current contractors were identified in the solicitation documents.

Notice text

2 versions

Update #2 · Latest ·

The contractor shall provide all licensed and qualified personnel, transportation, tools, equipment, materials and services required to furnish and install automatic door operators and handicap button access to existing doors at buildings 528 and 940 on Little Rock Air Force Base.


Furnish two Allegion/Stanley Access 75” M-Force overhead double door auto operators (or equal) and controls with one jamb style push plate, 1 surface standard surface mount push plate and three wireless push plates  Unit to fit a 6’-0” header opening above the doors.  Or equal characteristics: Surface mount above door single box with two operators.  Header size 6’-0”, will handle panels up to 48” wide and 350 pounds per opener, safety sensors to prevent closing on obstructions, operation with wireless touch buttons, 120VAC, 60HZ.  Units must operate with the removal of the manual door closure. Units in dark bronze anodized finish to match existing door frames.  Units configured to ANSI standard A156.19 Low Energy guidelines.  Contractor shall furnish all labor, materials, wiring, and connections needed for installation and operation of the unit.  Contractor shall furnish and install all electrical connections from the existing facility electrical panel to each of the doors to include breakers, conduit, wiring boxes etc.  


Estimated time of delivery shall be no later than 120 days of award.

A site visit will be conducted: Those wishing to participate in the site visit shall provide all information.
*Name
*DL State/number
*Date of Birth

UPDATED: Performance Work Statement (PWS)

Update #1 ·

The contractor shall provide all licensed and qualified personnel, transportation, tools, equipment, materials and services required to furnish and install automatic door operators and handicap button access to existing doors at buildings 528 and 940 on Little Rock Air Force Base.


Furnish two Allegion/Stanley Access 75” M-Force overhead double door auto operators (or equal) and controls with one jamb style push plate, 1 surface standard surface mount push plate and three wireless push plates  Unit to fit a 6’-0” header opening above the doors.  Or equal characteristics: Surface mount above door single box with two operators.  Header size 6’-0”, will handle panels up to 48” wide and 350 pounds per opener, safety sensors to prevent closing on obstructions, operation with wireless touch buttons, 120VAC, 60HZ.  Units must operate with the removal of the manual door closure. Units in dark bronze anodized finish to match existing door frames.  Units configured to ANSI standard A156.19 Low Energy guidelines.  Contractor shall furnish all labor, materials, wiring, and connections needed for installation and operation of the unit.  Contractor shall furnish and install all electrical connections from the existing facility electrical panel to each of the doors to include breakers, conduit, wiring boxes etc.  


Estimated time of delivery shall be no later than 120 days of award.

A site visit will be conducted: Those wishing to participate in the site visit shall provide all information.
*Name
*DL State/number
*Date of Birth

Files

File Type Posted
Combo.pdf PDF
Attachment 2_PWS.pdf PDF
Attachment 2_PWS.pdf PDF
Combo.pdf PDF
Attachment 1_Provisions and Clauses.pdf PDF
Attachment 3_Wage Determination.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
Vertical Transportation Equipment (VTE) Maintenance, Repair, & Inspection Services Little Rock Air Force Base, Arkansas 72099, United States · NAICS 238290 Air Mobility Command Total Small Business
WV-canaan VLY NWR-VC ADA doors NAICS 236220 — Total Small Business
ID- kooskia NFH-overhead door replace NAICS 238290 — Total Small Business
EC-ECAO Exterior Door Replacement NAICS 238350 — Total Small Business
R-410A LEAK DETECTORS (Bldgs 750, 751 & 768) Little Rock Air Force Base, Arkansas 72099, United States · NAICS 238220 Air Mobility Command Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity