API Fuel Tank Inspection - Moody AFB, GA
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- W9128F25QA016
- Agency
- ENDIST Omaha US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 541990 All Other Professional, Scientific, and Technical Services
- Place of performance
- Georgia 31699, United States
- Points of contact
-
- Charles Thirsk charles.thirsk@usace.army.mil
- Jae Chang jae.chang@usace.army.mil (314) 570-2931
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army Corps of Engineers (USACE) is seeking a contractor to perform API fuel tank external inspection services at Moody Air Force Base in Georgia. The solicitation requires a qualified contractor to conduct comprehensive inspections on four aboveground storage tanks following industry standards including API 653, NFPA 30, and UFGS guidelines. Key contract requirements include providing a Project Inspection Management Plan, Health and Safety Plan, and detailed inspection reports, with work to be performed between 0730-1630 hours Monday through Friday. The evaluation will be based on technical capability, specifically inspector expertise and certifications, contractor experience, and price reasonableness. Quotes are due by March 3, 2025, with contractors required to submit questions no later than 7 days before the proposal due date, and the offer must remain valid for 60 calendar days.
The solicitation is designated as a total small business set-aside under NAICS code 541990 for professional scientific and technical services. The contract covers four specific fuel storage tanks with capacities ranging from 189,000 to 420,000 gallons, located at Moody Air Force Base in Georgia. The period of performance is 120 calendar days from contract award, with contractors expected to complete comprehensive external inspections including ultrasonic testing, visual inspections of secondary containment, and testing of tank alarms and appurtenances. Key personnel requirements include a Certified API 653 Inspector and Project Manager. Draft inspection reports must be submitted within 28 days of field inspection, with final reports due 7 days after receiving comments. While specific pricing details are not disclosed in the solicitation, the contract will be awarded to the lowest-priced, technically acceptable offeror.
Notice text
The U.S. Army Corps of Engineers (USACE) is seeking a contractor to provide fuel tank inspection services at Moody Air Force Base (AFB), Georgia.
All details and requirements are provided in the Performance Work Statement (PWS) attached to this solicitation.
Attachments
| File | Type | Posted |
|---|---|---|
| Attachment J2 - Previous Inspection Report 5017-Tank 2.pdf | ||
| Attachment I - API External Template.docx | DOCX document | |
| Attachment B - Fuel Storage Tank LIst.xlsx | XLSX spreadsheet | |
| Combined Synopsis-Solicitation Moody AFB.pdf | ||
| Attachment 2 - Performance Work Statement (PWS).pdf | ||
| Attachment 1 - CLIN Schedule.pdf | ||
| Attachment J4 - Previous Inspection Report 5019-Tank 4.pdf | ||
| Attachment J3 - Previous Inspection Report 5018-Tank 3.pdf | ||
| Attachment J1 - Previous Inspection Report 5016-Tank 1.pdf | ||
| Attachment 4-Addendum to 52.212-1.pdf | ||
| Wage Determination.pdf | ||
| Attachment E - Inspection Telecon Briefing Template.docx | DOCX document | |
| Attachment D - MCP and MS Report.xlsx | XLSX spreadsheet | |
| Attachment C - Fuel Storage Tank Data Sheet.xlsx | XLSX spreadsheet | |
| Attachment A - General Installation Security Requirements.pdf |
Show all 15
Notice history
| Notice | Type | Posted |
|---|---|---|
| API Fuel Tank Inspection - Moody AFB, GA | Award Notice | |
| API Fuel Tank Inspection - Moody AFB, GA | Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity