Attachment B - Fuel Storage Tank LIst.xlsx
XLSX spreadsheet 15 KB Posted
- Attached to
- API Fuel Tank Inspection - Moody AFB, GA Federal contract opportunity
- Solicitation number
- W9128F25QA016
About this file
This is a fuel storage tank list spreadsheet (Attachment B) detailing four API fuel tanks at Moody Air Force Base in Georgia that require external inspection. The tanks have the following specifications: Two tanks (#05016 and #05019) have 420,000-gallon capacity with dimensions of 45' diameter x 34'6" height, while tanks #05017 and #05018 have capacities of 189,000 and 210,000 gallons respectively, both with dimensions of 35' diameter x 28'6" height. All tanks require ultrasonic testing (UT) and have two 36-inch manways each.
The list serves as supporting documentation for a U.S. Army Corps of Engineers solicitation (W9128F25QA016) for API fuel tank inspection services at Moody AFB. The spreadsheet indicates that roundness surveys, certified strapping charts, and IFR seal replacement are not required for any of the tanks, and there are no fuel disposal requirements noted.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment J4 - Previous Inspection Report 5019-Tank 4.pdf | ||
| Attachment J3 - Previous Inspection Report 5018-Tank 3.pdf | ||
| Attachment J1 - Previous Inspection Report 5016-Tank 1.pdf | ||
| Attachment 4-Addendum to 52.212-1.pdf | ||
| Wage Determination.pdf | ||
| Attachment E - Inspection Telecon Briefing Template.docx | DOCX document | |
| Attachment D - MCP and MS Report.xlsx | XLSX spreadsheet | |
| Attachment C - Fuel Storage Tank Data Sheet.xlsx | XLSX spreadsheet | |
| Attachment A - General Installation Security Requirements.pdf | ||
| Attachment 2 - Performance Work Statement (PWS).pdf | ||
| Attachment 1 - CLIN Schedule.pdf | ||
| Attachment J2 - Previous Inspection Report 5017-Tank 2.pdf | ||
| Attachment I - API External Template.docx | DOCX document | |
| Combined Synopsis-Solicitation Moody AFB.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PO 30 MDY
| Attachment B - PO 30 SP-POL-CMP-INSPECT-FY25-MDY | |||||||||||||||
| SITE CODE | INSTALLATION | STATE / COUNTRY | INSPECTION TYPE | FACILITY NUMBER | LOCAL ID # | FUEL TYPE | TANK CAPACITY (GA) | TANK DIAMETER (FT) | TANK LENGTH / HEIGHT (FT) | UT (Yes/No) | ROUNDNESS SURVEY Req. (Yes/No) | CERTIFIED STRAPPING CHART Req. (Yes/No) | REPLACE IFR SEAL (Yes/No) | Gallons Remaining will need to be disposed of | # Manways & Sizes |
| MDY | Moody | GA/USA | API External | 05016 | JAA | 420,000 | 45'-0" | 34'-6" | YES | NA | NA | NA | NA | 2 // 36" each | |
| MDY | Moody | GA/USA | API External | 05017 | JAA | 189,000 | 35'-0" | 28'-6" | YES | NA | NA | NA | NA | 2 // 36" each | |
| MDY | Moody | GA/USA | API External | 05018 | JAA | 210,000 | 35'-0" | 28'-6" | YES | NA | NA | NA | NA | 2 // 36" each | |
| MDY | Moody | GA/USA | API External | 05019 | JAA | 420,000 | 45'-0" | 34'-6" | YES | NA | NA | NA | NA | 2 // 36" each |