About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15 is soliciting installation of a dedicated pharmacy air handler at Harry S. Truman VAMC in Columbia, Missouri, with proposals due September 9, 2026. The procurement is set aside for Service-Disabled Veteran-Owned Small Businesses.
Place of performance is Columbia, Missouri. Work includes applied fireproofing of structural steel using mineral fiber and cementitious sprayed-on material compliant with ASTM E1042, Class (a), Category A, Type I. Fireproofing must achieve no cracking or spalling under specified deflection (ASTM E759); minimum cohesive/adhesive bond strength of 9.57 kPa for protected areas and 19.15 kPa for exposed areas (ASTM E736); minimum compressive strength of 48 kPa (ASTM E761); flame spread of 25 or less and smoke development of 50 or less (ASTM E84); and resistance to fungi growth (ASTM G21). Asbestos-containing materials are prohibited. Minimum applied dry density is 240 kg/m³ for underside of walk-on deck, beams, and columns in interstitial spaces, with higher densities of 640 kg/m³ permitted in mechanical rooms or parking garages. Fire ratings required are one-hour for roof and two-hour for columns, beams, and girders. Field testing will be performed by a VA-retained testing laboratory for thickness, density, cohesion/adhesion, and bond impact strength. This is Amendment 0004 to solicitation 36C25526R0159; offerors must acknowledge receipt of the amendment by the closing date. The NAICS code is 236220, Commercial and Institutional Building Construction; PSC is Z2DA, Repair or Alteration of Hospitals and Infirmaries.
Notice text
Amendment 0004 - Install Dedicated Pharmacy Air Handler, 589A4-25-102
Attachments
| File | Type | Posted |
|---|---|---|
| 36C25526R0159 0004.pdf | ||
| 07 81 00 Applied Fireproofing.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Amendment 0004, Install Dedicated Pharmacy Air Handler | Solicitation | |
| Z2DA--589A4-25-102, Install Dedicated Pharmacy Air Handler | Solicitation | |
| Z2DA--589A4-25-102, Install Dedicated Pharmacy Air Handler | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity