Amendment 0004, Install Dedicated Pharmacy Air Handler

Closed Solicitation Posted

Solicitation number
Amendment4-1
Agency
Veterans Integrated Service Network 15 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

NAICS code
236220 Commercial and Institutional Building Construction
PSC
Z2DA Repair Or Alteration Of Hospitals And Infirmaries
Place of performance
Missouri 65201, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15 is soliciting installation of a dedicated pharmacy air handler at Harry S. Truman VAMC in Columbia, Missouri, with proposals due September 9, 2026. The procurement is set aside for Service-Disabled Veteran-Owned Small Businesses.

Place of performance is Columbia, Missouri. Work includes applied fireproofing of structural steel using mineral fiber and cementitious sprayed-on material compliant with ASTM E1042, Class (a), Category A, Type I. Fireproofing must achieve no cracking or spalling under specified deflection (ASTM E759); minimum cohesive/adhesive bond strength of 9.57 kPa for protected areas and 19.15 kPa for exposed areas (ASTM E736); minimum compressive strength of 48 kPa (ASTM E761); flame spread of 25 or less and smoke development of 50 or less (ASTM E84); and resistance to fungi growth (ASTM G21). Asbestos-containing materials are prohibited. Minimum applied dry density is 240 kg/m³ for underside of walk-on deck, beams, and columns in interstitial spaces, with higher densities of 640 kg/m³ permitted in mechanical rooms or parking garages. Fire ratings required are one-hour for roof and two-hour for columns, beams, and girders. Field testing will be performed by a VA-retained testing laboratory for thickness, density, cohesion/adhesion, and bond impact strength. This is Amendment 0004 to solicitation 36C25526R0159; offerors must acknowledge receipt of the amendment by the closing date. The NAICS code is 236220, Commercial and Institutional Building Construction; PSC is Z2DA, Repair or Alteration of Hospitals and Infirmaries.

Notice text

Amendment 0004 - Install Dedicated Pharmacy Air Handler, 589A4-25-102

Attachments

Files attached to this notice, newest first
File Type Posted
36C25526R0159 0004.pdf PDF
07 81 00 Applied Fireproofing.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Amendment 0004, Install Dedicated Pharmacy Air Handler This notice · Latest solicitation Solicitation
Z2DA--589A4-25-102, Install Dedicated Pharmacy Air Handler Solicitation
Z2DA--589A4-25-102, Install Dedicated Pharmacy Air Handler Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity