Air control group squadron operations tinker AFB, OK

Awarded Award Notice Posted

Solicitation number
W912BV-15-R-0068
Agency
ENDIST Tulsa US Army Corps of Engineers, Department of Defense
Awarded
to Fortis Sbjv, LLC
Set-aside
Total Small Business

Opportunity facts

Contract number
W912BV-16-C-0004 Federal contract award
NAICS code
236220 Commercial and Institutional Building Construction
PSC
Not on record
Place of performance
Tinker Air Force Base, Oklahoma Oklahoma City, Oklahoma 73145, United States

Notice details come from SAM.gov. Updated .

Notice text

8 versions

Update #8 · Latest ·

Added: Nov 09, 2015 2:09 pm

Amendment 0007 corrects a typo in Amendment 0006 and confirms the proposal due date is 23 November 2015.

Update #7 ·

Added: Nov 06, 2015 11:57 am Amendment 0006 issued 11/6/15 with spec/dwg changes, due date remains the same.

Update #6 ·

Added: Nov 05, 2015 9:25 am The proposal due date has been extended to 23 November 2015 to allow time to answer contractor RFIs.

Update #5 ·

Added: Nov 03, 2015 12:30 pm Amendment 0004 has been added with specification changes and administrative changes to price schedule and Division 00 sections.

Update #4 ·

Added: Oct 28, 2015 5:22 pm Site visit attendance sign in sheets uploaded.

Update #3 ·

Added: Oct 16, 2015 3:33 pm Modified: Oct 20, 2015 2:20 pmTrack Changes Amendment 0003 has been added on 10/20/15 changing the site visit information and the proposal due date has been extended to 11/13/15.

Update #2 ·

Added: Oct 16, 2015 3:33 pm Amendment 0002 has been added on 10/16/15 and the proposal due date has been extended to 11/4/15.

Update #1 ·

Added: Sep 10, 2015 3:06 pm PRESOLICITATION NOTICE
W912BV-15-R-0068
Estimated Solicitation release date: 25 Sep 2015.
AIR CONTROL GROUP SQUADRON OPERATIONS
TINKER AFB, OK

This is a fully designed (government provides design)construction project including a two-story consolidated operations and Air Control Group management facility. Approximate size is 32,000 square feet. Building design includes an Operations Desk, ORC Ops Office, OSF Aviation Manager Office, Storage, Large 250 person Briefing Room (Auditorium), Building Manager's Office, Mobility Storage, Mobility Office, Medical Office, Flight Medical Exam Room, multiple Command Suites, Conference Rooms, Special Projects Office; Heritage Room, Mission Planning Flight Deck Room, Pilot's/Navigator's Workroom, Flight Engineer Workroom, Physical Training Room, CVZ Room, Public Affair's Office, Career Adviser's office, Male and Female Latrine/Shower/Locker Rooms, Laundry Room and Janitor's Closet, Standards Evaluation Testing, Air Battle Management Work Room and required building support spaces. Secure areas are included. Other sensitive work areas are also included. Supporting work includes site work, utilities, bus drop off area, and parking. Antiterrorism requirements for buildings IAW UFC 4-0 10-01and building access standards IAW Americans with Disabilities Act and Architectural Barriers Act (ADA/ABAAG) apply. Sustainability IAW Executive Order 13423, 10 USC 2802(c) applies. Air conditioning: 100 tons is included. An option is included for the construction contractor to provide furnishings for the facility. The magnitude of this construction project is $10,000,000 to $25,000,000.

Attachments

Show all 11

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Air control group squadron operations tinker AFB, OK This notice · Latest Award Notice
SOURCES SOUGHT SYNOPSIS for 513th Air Squadron Operations Facility, Tinker AFB, Oklahoma under a design/bid/build construction contract. Original Award Notice

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity