6640--36C25523Q0698 - pathology equipment - top
Closed Pre-Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- 36C25523Q0698
- Agency
-
Veterans Integrated Service Network 15
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 334516 Analytical Laboratory Instrument Manufacturing
- PSC
- 6640 Laboratory Equipment And Supplies
- Place of performance
- Colmery-O'Neil Va Medical Center Topeka, Kansas 66622, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Colmery-O Neil VA Medical Center in Topeka, Kansas is seeking to purchase new pathology equipment, specifically a Mopec Grossing Station, a Thermo Scientific Heratherm Advanced Protocol Microbiological Incubator, and an Epredia Microm HM525 NX Cryostat. These devices will be used for dissecting, cutting, and processing tissue and biopsy pathology specimens, growing bacterial cultures to isolate infectious organisms, and cutting histological slides for rapid intraoperative disease diagnoses. The equipment must meet specific technical and operational requirements as detailed in the statement of work.
Products and Services to be provided:
- Mopec Grossing Station
- Thermo Scientific Heratherm Advanced Protocol Microbiological Incubator
- Epredia Microm HM525 NX Cryostat
- Installation and setup of the equipment
- Training on the use and maintenance of the equipment
Notice text
STATEMENT OF WORK
Colmery-O Neil VA Medical Center
Topeka, Kansas
Pathology Equipment
BRAND NAME OR EQUAL TO:
Mopec Grossing Station, Thermo Scientific Heratherm Advanced Protocol Microbiological
Incubator, Epredia Microm HM525 NX Cryostat
Topeka VA Histology Lab is requesting purchase of new pathology equipment: Mopec Grossing Station, Thermo Scientific Heratherm Advanced Protocol Microbiological Incubator, Epredia Microm HM525 NX Cryostat. This Station is used for dissecting, cutting, and processing tissue and biopsy pathology specimens to aid in diagnosing malignant and non-cancerous findings in a clean environment. This incubator is used for growing bacterial cultures to determine and isolate organisms that can cause infections in the body. The cryostat is utilized in the Histology department to cut histological slides during a frozen section allowing for rapid intraoperative disease diagnoses.
Salient Characteristics
Histology Grossing Station
(Width 4 feet Depth 29 inches)
Right hand sink with faucet mixing-flow control
Backdraft ventilation
In-house ventilation (Dual 8 duct stubs)
Stainless steel construction
Four GFCI Receptacles with USB
Touchscreen Control Panel and Alert System
On-Demand Front Air System (FAS)
Seismic Anchoring points
Integrated Hood Mounted Camera Bracket
Ensemble Pegboard system and magnetic instrument tool bar
Sliding work surface white cutting board
2 wire ports for cord management
Large and small Organizer bin
Perforated grid plate
1HP Garbage disposal
115V electrical requirement Amperage: 10A HERTZ: 60Hz
Hand spray rinse option
FUME Detection System needed
LED Light Bar
Pegboard Requisition Form Holder
Microbiology Incubator
(footprint 3.2 sqft)
Gravity or Dual convection technology
Temperature range: Ambient +5 °C to 105 °C
Spatial temperature deviation at 37 °C: ± 0.6 °C /± 0.2°C
Temperature deviation overtime at 150 °C: ± 0.1°C
Stainless steel chamber
Digital display. Programmable settings
Chamber volume: 2.3 cuft
Blower and light switches.
120V electrical requirement HERTZ: 60Hz
Cryostat-Microtome
Disposable blade holder with low profile blades
Footprint approximately 36 x 36
Interior light
Heat extracting device
Stable specimen clamp
Rapid freezing shelf
Frostfree, encapsulated microtome
Specimen chucks
Chamber disinfection cycle included
Automatic defrost cycle included
Ability to operate on standard 110v electrical service
Files
| File | Type | Posted |
|---|---|---|
| 36C25523Q0698_2.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| 6640--36C25523Q0698 - pathology equipment - top | Solicitation | |
| This notice | Pre-Solicitation | |
| 6640--36C25523Q0698 - pathology equipment - top brand name or equal to | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| NWI Offsite Pathology Services | Veterans Integrated Service Network 23 | Total Small Business | |
| 6695--surgery globus instrument set | Veterans Integrated Service Network 19 | Service-Disabled Veteran-Owned Small Business | |
| Q301--New Reference Lab Testing | Legacy VISN 15 | Veterans Integrated Service Network 15 | No set-aside | |
| Baxter/Hill-Rom Helux Pro Surgical Light System | Office of Logisitics and Acquisition Operations | No set-aside | |
| J066--Sakura Service Agreement | Follow on Base+4 | Start: 1/21/27 Columbus VAACC | Veterans Integrated Service Network 10 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity