About this opportunity
The Department of Veterans Affairs (VA) is seeking sources for a new Washer Disinfector for the Northport VA Medical Center. The preferred model is the Getinge 8668 Washer, which would be compatible with the facility's existing equipment. The washer disinfector must meet specific criteria, including compliance with ISO 15882 regulations, the ability to accommodate 18 trays per cycle, and detailed physical dimensions. Key salient characteristics include utilization of facility-supplied utilities, a microprocessor control system, and power sliding doors. Interested vendors must provide a capability statement addressing their qualifications and ability to provide the required commodities. Responses are due by 3:00 PM Eastern on May 31, 2024 and should be submitted to the Contract Specialist.
This is a sources sought notice only and does not commit the government to issuing a solicitation or awarding a contract. All contractor responses will be accepted, and this is not a set-aside requirement. The government is not obligated to pay for or reimburse any costs associated with responding to this sources sought request. The government will not be bound to this information if a solicitation is issued.
Notice text
This is a SOURCES SOUGHT ANNOUNCEMENT ONLY.  It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified businesses interested and capable of providing the requested commodities.
The NAICS Code is 339113; size standard is 750 employees; PSC is 6515.
Not a set-aside. All contractor responses accepted.
Responses to this notice shall include the following: (a) company name  b) address (c) socio-economic status, (d) point of contact (e) phone, fax, and email (f) SAM UEI number (g) Cage Code (h) Tax ID Number (i) and must  provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor and provide the commodities described below.  Â
OBJECTIVE:
Northport VA Medical Center is seeking sources for a Washer Disinfector.
BRAND NAME OR EQUAL
SCOPE:
The Sterile Processing Service requires new washer disinfector. We currently use a Getinge washer disinfector, the Getinge 8668 Washer is the desired model as it is an upgraded version of our existing equipment would support a continuous standard of care. The standardization of medical equipment benefits both SPS and Biomedical staff as they are trained in how to use and maintain the equipment so there will be no learning curve.
The Washer Disinfector system must contain and apply as follows:
Washer must be in compliance with ISO 15882 regulations.
Must accommodate 18 trays per cycle in given footprint..
Must have the following characteristics:
Outer dimensions
Width
1110 mm (3'7 11/16")
Depth
990 mm (3' 3")
Height
1960 mm (6'5 13/16")
Width
650 mm (2'1 9/16")
Depth
810 mm (2'7 7/8")
Height
667 mm (2'2 1/4")
Effective chamber volume
351 L (92.7 gal.)
Gross chamber volume
480 L (126.8 gal.)
Must have monitoring system that confirms all wash parameters are met.
Installation and connected to facility plumbing and electrical systems.
Utility Connection Package
Condensate Cooling Kit
Recess Trim for both sides of Washer
SALIENT CHARACTERISTICS:
Utilizing facility supplied steam, water and electric
Getinge Air Glide System (AGS), or equivalent
Maximum overall width dimension 38
Ability to process 18 DIN trays per cycle
Microprocessor control system (The unit is controlled by a microcomputer that monitors and controls all unit operations and functions and provides both audible and visual indications of deviations).Â
Powered vertical sliding doorsÂ
Site electrical configuration 208V, 3phase, with various options.
Site Plumbing configuration:
Drain size: 4 Sanitary line to floor sink
Water line size: 1 HW; 1 CW
Compressor line: ½ CA
Provide user manuals and operating/ maintenance training
Provide test machine with test loads
Provide a standard warranty with the machine
Provide all test/ commissioning certifications upon completion of installation
Place of Delivery:
Northport VA Medical Center
79 Middleville Rd
Northport, NY 11768
The Government is not obligated to, nor will it pay for or reimburse any costs associated with responding to this Sources Sought request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Notice to Potential Offerors: All Offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM located on the web at www.sam.gov). It is desirable that any Offeror to have completed their business Online Representations and Certifications Application (ORCA). Additionally, all Service Disabled Veteran Owned Small Businesses or Veteran Owned Small Businesses who respond to a solicitation on this project must be registered with the Department of Veterans Affairs Center for Veterans Enterprise VetBiz Registry located at http://vip.vetbiz.gov. Requests for information and resultant responses shall be submitted directly to the contracting officer,
Response due no later than 15:00 Eastern Standard Time on May 31, 2024 to Paul Speedling, Contract Specialist at Paul.Speedling@va.gov.
Files
| File | Type | Posted |
|---|---|---|
| 36C24224Q0684.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| 6515--equipment - washer disinfector model 8668 - brand name or equal - getinge USA sales LLC | Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| 6515--Sterilizer | Veterans Integrated Service Network 17 | No set-aside | |
| J072--JR/BP pots and pans room | washington DC VAMC | Veterans Integrated Service Network 5 | No set-aside | |
| 6530--NX EQ Environmental Disinfection Systems Pulsed Xenon UV Light (VA-27-00012571) | VA Strategic Acquisition Center Frederick | No set-aside | |
| DA10--Steris Software Connectivity | Veterans Integrated Service Network 21 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity