6515--Surgical Tables

Closed Solicitation Posted

Solicitation number
36C26226Q1175
Agency
Veterans Integrated Service Network 22 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
339113 Surgical Appliance and Supplies Manufacturing
PSC
6515 Medical And Surgical Instruments, Equipment, And Supplies
Place of performance
Department of Veterans Affairs VA Albuquerque Healthcare System Albuqeruqeu, New Mexico 87108, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22 seeks two surgical tables equivalent to MAX5 Surgical Tables System for the VA Albuquerque Healthcare System Pain Clinic/Anesthesia services, with quotes due July 31, 2026 at 10:00 AM Pacific Time. This is a total small business set-aside procurement conducted as a combined synopsis and request for quotes under solicitation number 36C26226Q1175.

Place of performance is Villa De Paz Transitional Housing, Albuquerque, New Mexico. The existing surgical tables have reached their lifetime repair cap and are no longer eligible for repairs. Quoted items must meet or exceed salient characteristics: minimum 500 lbs weight capacity regardless of table positioning, tabletop length minimum 80 inches and width minimum 24 inches, motorized longitudinal and lateral travel of minimum 10 inches each, motorized height lift with lateral tilt and Trendelenburg/reverse Trendelenburg capability, remote hand control, multi-function foot pedal, integrated emergency stop switch with manual overrides, four 5-inch heavy duty locking casters with 360-degree full swivel, 120V medical-grade power cord, radiolucency for C-arm imaging, modular side rails, minimum two articulating armboards, dual-sided lead Max table drape minimum 48 by 36 inches with 0.5mm Pb equivalent, FDA compliance, and ISO 13485 Class II certification. All items must be new, not refurbished or remanufactured. Procurement includes four armboards with side rail locking systems and four modular side rail systems. Delivery is FOB Destination with shipping costs included in unit pricing. Vendors must be Original Equipment Manufacturers, authorized dealers, authorized distributors, or authorized resellers verified by OEM authorization letter; no gray market or counterfeit items are acceptable per VAAR 852.212-71. Questions are due July 22, 2026 at 10:00 AM Pacific Time. NAICS code is 339113 (Surgical Appliance and Supplies Manufacturing); PSC code is 6515.

Notice text

2 versions

Update #2 · Latest ·

The amendment 00001 under Solicitation/RFQ 36C26226Q1175 is hereby issued to reiterate and clarify that a foot pedal is require for each surgical table included in this requirement.

The quote due date is hereby extended until 7/31/2026 10am Pacific Local time. All contractors must acknowledge this amendment and must submit a new quote to this solicitation. Any previously submitted quotes will not be considered or evaluated.

All other terms and conditions remain unchanged.

Functional/Salient Characteristics:

The new surgical tables must meet or exceed the following minimum technical/salient requirements:

Capacity: A minimum weight capacity of 500 lbs. regardless of table positioning.

Dimensions: Tabletop length must be a minimum of 80 inches; width a minimum of 24 inches.

Travel (Motorized): Surgical table must support a minimum of 10 inches of Longitudinal travel and a minimum of 10 inches of Lateral travel.

Must have tilt options through motorized height lift, lateral tilt, and Trendelenburg/reverse Trendelenburg tilt.

Each surgical table must come with both a Remote Hand Control and a Multi-function Foot Pedal.

Must have an integrated Emergency Stop switch and manual overrides.

Must have a minimum of four 5 heavy duty locking casters with 360° full swivel capability.

Power must meet: Standard 120V medical-grade power cord.

Radiolucency: Must allow medical staff to get optimized C-arm images with minimal attenuation.

Each surgical table must come with modular side rails specifically for mounting accessories.

Each surgical table must have a minimum of two (2) articulating armboards that lock securely into the module side rails.

Dual-sided Lead Max Table Drape: must be a minimum of 48 x36 with a minimum of 0.5mm Pb equivalent for scatter radiation protection.

Surgical tables must be FDA-compliant and ISO 13485-certified Class II medical device.

All items must be new/not refurbished.

No special-in-service is requested at this time. Standard dock delivery.

Deliverables:

CLIN

DESCRIPTION

QTY

UOM

0001

Surgical Tables equivalent to Surgical Tables MAX 5 with height adjustment, lateral tilt, Trendelenberg, Longitudual travel & Lateral Travel and MAX 5 Move Foot Control STJ05-LW1000-X100

2

EA

0002

Armboard with Side Rail Locking System & Arm pad

4

EA

0003

Modular Side Rail System

4

EA

0004

Dual-sided Max Table drape

2

EA

B.3 PRICE/COST SCHEDULE

ITEM INFORMATION

ITEM NUMBER

DESCRIPTION OF SUPPLIES/SERVICES

QUANTITY

UNIT

UNIT PRICE

AMOUNT

0001

2.00

EA

_____________

_____________

Surgical Tables equivalent to Surgical Tables MAX 5 with height adjustment, lateral tilt, Trendelenberg, Longitudual travel & Lateral Travel and foot control (STJ05-LW1000-X100)

IF EQUAL TO, PLEASE PROVIDE BRAND NAME _____________ & MODEL NUMBER _____________

PRINCIPAL NAICS CODE: 339113 - Surgical Appliance and Supplies Manufacturing

PRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies

LOCAL STOCK NUMBER: MAX 5

0002

4.00

EA

_____________

_____________

Armboard with Side Rail Locking System & Arm pad

IF EQUAL TO, PLEASE PROVIDE BRAND NAME _____________ & MODEL NUMBER _____________

PRINCIPAL NAICS CODE: 339113 - Surgical Appliance and Supplies Manufacturing

PRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies

LOCAL STOCK NUMBER: S-ARM

0003

4.00

EA

_____________

_____________

Modular Side Rail System

IF EQUAL TO, PLEASE PROVIDE BRAND NAME _____________ & MODEL NUMBER _____________

PRINCIPAL NAICS CODE: 339113 - Surgical Appliance and Supplies Manufacturing

PRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies

LOCAL STOCK NUMBER: MSRS

0004

2.00

EA

_____________

_____________

Dual-sided lead Max table drape for CLIN 0001

IF EQUAL TO, PLEASE PROVIDE BRAND NAME _____________ & MODEL NUMBER _____________

PRINCIPAL NAICS CODE: 339113 - Surgical Appliance and Supplies Manufacturing

PRODUCT/SERVICE CODE: 6515 - Medical and Surgical Instruments, Equipment, and Supplies

LOCAL STOCK NUMBER: TS-48362

GRAND TOTAL

_____________

Update #1 ·

This is a combined synopsis/solicitation total small business set aside for commercial supplies prepared in accordance with the format in Subpart 12.6, as supplemented with the additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This is a request for quotes under solicitation number: 36C26226Q1175

VA Albuquerque Healthcare System Pain Clinic/Anesthesia services require a procurement of Two (2) each of surgical tables equivalent to MAX5 Surgical Tables System that is necessary to meet patient safety & clinical requirements. Old surgical tables have reached lifetime repair cap per Biomed and are no longer eligible for repairs. The contractor shall furnish and deliver two (2) new surgical tables equivalent to MAX5 surgical tables that meet or exceed the specified functional and performance requirements. Shipping term is FOB Destination. Shipping must be included in the unit cost.

NOTE: Potential quoters must be aware that the items being acquired are procured as Brand Name or Equal. For those items that are or equal , a description of the salient characteristics is outlined below. It is quoter s responsibility to demonstrate its quote meeting the salient physical and functional characteristics included in this solicitation. If the quote does NOT demonstrate, the offer will be considered non-responsive. The interested parties bear full responsibility to ensure their submission demonstrates to the government that they can satisfy the requirement by providing the brand name or equal to the supplies being requested.

VAAR 852.212-71 Gray Market and Counterfeit Items clause applies on this acquisition. No remanufacturers or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM signed. The letter must either state specific product(s) quoted or that the quoter is an authorized distributor for all the manufacturer s products. This letter must be on the manufacturer s letterhead and contains the signature of an authorized official for the manufacturer. If the interested contractor fails to provide a signed letter from the OEM (unless the contractor is the OEM), the contractor s response will be deemed non responsive and will not be considered for award.

CLIN

DESCRIPTION

QTY

UOM

0001

Surgical Tables equivalent to Surgical Tables MAX 5 with height adjustment, lateral tilt, Trendelenberg, Longitudual travel & Lateral Travel and foot control

2

EA

0002

Armboard with Side Rail Locking System & Arm pad

4

EA

0003

Modular Side Rail System

4

EA

0004

Dual-sided Max Table drape for CLIN 0001

2

EA

The solicitation will be in accordance with Revolutionary FAR Overhaul (RFO) Part 12, and 19, Acquisition of Commercial Items, Simplified Acquisition Procedures, Small Business Programs, and Veteran Affairs Acquisition Regulations as supplemented with additional information in this notice. The North American Industrial Classification System (NAICS) code for this requirement is 339113, Size Standard 800 Employees. The Contractor shall adhere to all federal and state laws and regulations in effect during the term of this contract. The Government intends to award a firm-fixed-price contract. The Contract begins on the date of award.

System updates may lag policy updates. The System for Award Management (SAM) may continue to require entities to complete representations based on provisions that are not included in agency solicitations. Examples include 52.222-25, Affirmative Action Compliance, and paragraph (d) of 52.212-3, Offeror Representations and Certifications Commercial Products and Commercial Services. Contracting officers will not consider these representations when making award decisions or enforce requirements. Entities are not required to, nor are they able to, update their entity registration to remove these representations in SAM.

In advancement of Section 2 of Executive Order 14208, the removal of requirements related to Executive Order 14057 eliminates all non-statutory sustainability requirements or preferences in purchases of food service wares, including paper straws. In addition to removing requirements related to Executive Order 14057, the attachment also reflects recent updates to Code of Federal Regulation citations for the U.S. Department of Agriculture s BioPreferred® Program, a statutory purchasing preference program.

Key solicitation milestones are: Submit any questions regarding this procurement via email to Hestia.Sim@va.gov no later than 10am Pacific Local Time Wednesday, July 22, 2026. No questions will be answered after this date/time unless determined to be in the best interest of the Government as determined by the Contracting Officer. Telephonic questions will not be accepted or returned. RFI responses will be responded to as necessary in amendment format which will be posted to contract opportunities at http://SAM.gov.

Due to time constraints, responses to the solicitation shall be due on Tuesday, July 28, 2026 at 10:00 Pacific Time. Offerors are advised that it is your responsibility to review and monitor the website frequently to ensure you have the most up to date information, including amendments. Correspondence or questions may be directed to Hestia Sim, Contracting Specialist at Hestia.Sim@va.gov with 36C26226Q1175, Surgical Tables in the subject line within 48 hours of release of this notice. Telephone inquiries will not be honored. Inquiries after the allotted period may not be responded to due to the time constraints of the procurement. All offerors must be registered at www.sam.gov to do business with the Government. Ensure your registration is correct, current and has not expired.

Attachments

Files attached to this notice, newest first
File Type Posted
36C26226Q1175 0001.docx DOCX document
36C26226Q1175.docx DOCX document

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity