The Department of Veterans Affairs (VA) Non-Expendable Equipment National Program is seeking vendors to provide the Stryker brand Tourniquets: Pneumatic or equal commodities that meet specified salient characteristics. This is a single-award Requirements contract with a 12-month base period and four 12-month option periods. The VA will evaluate quotes based on the vendors' ability to meet the salient characteristics, which cover requirements such as single/dual port options, pressure range, procedure time setting, battery backup, interface, alarms, and calibration capabilities. Quotes are due by 11:59PM EST on May 21, 2024, and the Government reserves the right to award without discussions.

This procurement is issued as full and open competition, with no set-aside designation. The associated NAICS code is 339112 Surgical and Medical Instrument Manufacturing, with a size standard of 1,000 employees. The contract has 56 specific line items for the Tourniquets: Pneumatic product line, including control units, cuffs, tubing, and accessories. Delivery is FOB destination, and the period of performance is for one base year with four option years.

Notice text

Combined Synopsis/Solicitation Notice

Combined Synopsis/Solicitation Notice

Combined Synopsis/Solicitation Notice

Page 3 of 8

Combined Synopsis/Solicitation Notice

Page 3 of 8

Combined Synopsis/Solicitation Notice

Combined Synopsis/Solicitation Notice

Page 3 of 8

Solicitation Number:

36C10G24Q0120

Notice Type:

COMBINED SYNOPSIS/SOLICITATION

This is a combined synopsis/solicitation for brand name or equal commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice.

This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued.

Solicitation number 36C10G24Q0120 is issued for this combined synopsis/solicitation; this solicitation is being issued as a Request for Quote (RFQ). This combined synopsis/solicitation incorporates provisions and clauses in effect through Federal Acquisition Regulation; Federal Acquisition Circular (FAC) FAC 2024-04, 05/01/2024.

Requirement Description:

The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Tourniquets: Pneumatic product line as a candidate for a VA-wide (otherwise referred to as national ) single Requirements contract award.

Tourniquets: Pneumatic, are designed to circumferentially constrict/compress an extremity for a limited period of time by applying a precise amount of pressure using an automated gas-inflated cuff. The pressure is applied upon the limb surface and underlying tissues using the cuff; pressure is then transferred to the blood vessels causing a temporary occlusion. Pneumatic tourniquets are used mainly during surgical procedures on the extremities enabling surgeons to perform procedures in bloodless operative fields.

A single award Requirements contract will be awarded IAW FAR 52.211-6 Brand Name or Equal in accordance with all terms, conditions, provisions, specifications, and schedule of this solicitation herein. Quotes shall contain the terms for cost/price and technical capabilities of the brand name or equal equipment. The Government reserves the right to award without discussions.

The associated North American Industrial Classification System (NAICS) code for this procurement is 339112 Surgical and Medical Instrument Manufacturing: Medical and Surgical Instruments, Equipment, and Supplies. and the associated size standard is 1,000 employees. This procurement action is issued as full and open.

This acquisition is for a single award Requirements contract in accordance with FAR Part 16.5 for Tourniquets: Pneumatic as identified in ATTACHMENT A PRICE COST SCHEDULE NX EQ Tourniquets: Pneumatic. All interested companies shall provide a quote for all Contract

Line-Item Numbers (CLINs) listed in ATTACHMENT A PRICE COST SCHEDULE NX EQ Tourniquets: Pneumatic.

The ordering period is for one 12-month base year with four 12-month option years. Delivery is FOB destination. Firm-Fixed Price Orders will be placed against this contract in writing and will provide the delivery locations, delivery dates and exact quantities.

The FAR provision at 52.212-1, Instructions to Offerors Commercial, applies to this acquisition including attached addenda to the provision.

The FAR provision at 52.212-2, Evaluation -- Commercial Items, and the specific evaluation criteria as attached addenda also apply to this acquisition.

The Offeror is to include a completed copy of the provision at 52.212-3, Offeror Representations and Certifications -- Commercial Items, with its offer.

Clause at 52.212-4, Contract Terms and Conditions -- Commercial Items, applies to this acquisition and a statement regarding any addenda to the clause. Addendum is attached.

Clause at 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders -- Commercial Items, applies to this acquisition and a statement regarding which, if any, of the additional FAR clauses cited in the clause are applicable to the acquisition. Addendum is attached.

All interested quoters must be registered in the System for Award Management (SAM) prior to submitting a quote. You may access SAM at https://sam.gov/SAM/.

All questions regarding this combined synopsis/solicitation are due via email by 11:59PM EST on May 15th, 2024, to Contract Specialist, Alanna Wilson, Alanna.Wilson@va.gov and Contracting Officer, Sara Vickroy at Sara.Vickroy@va.gov. No calls will be accepted.

Quotes are due via email by 11:59PM EST on May 21st, 2024, to Contract Specialist, Alanna Wilson, Alanna.Wilson@va.gov and Contracting Officer, Sara Vickroy at Sara.Vickroy@va.gov.

SCOPE OF WORK:

The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Tourniquets: Pneumatic product line as a candidate for a VA-wide (otherwise referred to as national ) single Requirements contract award.

Tourniquets: Pneumatic, are designed to circumferentially constrict/compress an extremity for a limited period of time by applying a precise amount of pressure using an automated gas-inflated cuff. The pressure is applied upon the limb surface and underlying tissues using the cuff; pressure is then transferred to the blood vessels causing a temporary occlusion. Pneumatic tourniquets are used mainly during surgical procedures on the extremities enabling surgeons to perform procedures in bloodless operative fields.

The Contractor must demonstrate the ability to meet all requirements for the solicitation. The objective is to provide Tourniquets: Pneumatic to be used by clinicians throughout the VA medical centers and facilities. The period of performance is for one (1) 12-month base period with four (4) twelve (12) month option periods.

REQUIREMENT

This requirement will be IAW FAR clause 52.211-6, Brand Name or Equal which requires the quoter indicate that each product being offered as an equal product to the Stryker® Tourniquets: Pneumatic. For each equal Tourniquets: Pneumatic product, the offeror must include a description reflecting the salient characteristics (SC) and level of quality that will satisfy the salient physical, functional, or performance characteristics of the equal product(s) specified in the solicitation. The quoter must also clearly identify the item by brand name (if any) and make/model number. Finally, the quoter must include descriptive literature, such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the contracting officer, and clearly describe any modifications it plans to make to a product to make it conform to the solicitation requirements.

The following line items comprise the Tourniquets: Pneumatic Product Line:

Contract

Line

Items

Manufacture

Part Number

Description

0001

Stryker

5920-011-000

SmartPump Dual Channel

0002

Stryker

5920-013-000

SmartPump Rolling Stand

0003

Stryker

5921-109-135

Disp. 9x1.75, 1Bla, 1Prt, Quick Connect

0004

Stryker

5921-209-135

Disp. 9x2.75, 1Bla, 1Prt, Quick Connect

0005

Stryker

5921-112-135

Disp. 12x2, 1Bla, 1Prt, Quick Connect

0006

Stryker

5921-212-135

Disp. 12x3.5, 1Bla, 1Prt, Quick Connect

0007

Stryker

5921-115-135

Disp. 15x2.5, 1Bla, 1Prt, Quick Connect

0008

Stryker

5921-018-135

Disp. 18x3, 1Bla, 1Prt, Quick Connect

0009

Stryker

5921-218-135

Disp. 18x4, 1Bla, 1Prt, Quick Connect

0010

Stryker

5921-024-135

Disp. 24x4, 1Bla, 1Prt, Quick Connect

0011

Stryker

5921-030-135

Disp. 30x4, 1Bla, 1Prt, Quick Connect

0012

Stryker

5921-034-135

Disp. 34x4, 1Bla, 1Prt, Quick Connect

0013

Stryker

5921-044-135

Disp. 44x4, 1Bla, 1Prt, Quick Connect

0014

Stryker

5921-112-235

Disp. 12x2, 1Bla, 2Prt, Quick Connect

0015

Stryker

5921-212-235

Disp. 12x3.5, 1Bla, 2Prt, Quick Connect

0016

Stryker

5921-115-235

Disp. 15x2.5, 1Bla, 2Prt, Quick Connect

0017

Stryker

5921-018-235

Disp. 18x3, 1Bla, 2Prt, Quick Connect

0018

Stryker

5921-218-235

Disp. 18x4, 1Bla, 2Prt, Quick Connect

0019

Stryker

5921-034-235

Disp. 34x4, 1Bla, 2Prt, Quick Connect

0020

Stryker

5921-044-235

Disp. 44x4, 1Bla, 2Prt, Quick Connect

0021

Stryker

5921-018-245

Disp. 18x5.5, 2Bla, 2Prt, Quick Connect

0022

Stryker

5921-024-235

Disp. 24x4, 1Bla, 2Prt, Quick Connect

0023

Stryker

5921-018-145

Disp. 18x5.5, 2Bla, 1Prt, Quick Connect

0024

Stryker

5921-024-145

Disp. 24x5.5, 2Bla, 1Prt, Quick Connect

0025

Stryker

5921-109-235

Disp. 9x1.75, 1Bla, 2Prt, Quick Connect

0026

Stryker

5921-209-235

Disp. 9x2.75, 1Bla, 2Prt, Quick Connect

0027

Stryker

5921-030-235

Disp. 30x4, 1Bla, 2Prt, Quick Connect

0028

Stryker

5921-024-245

Disp. 24x5.5, 2Bla, 2Prt, Quick Connect

0029

Stryker

5920-000-304

Y Adaptor

0030

Stryker

5920-000-203

quick lock to quick lock

0031

Stryker

5920-000-204

Y-fill, quick to quick 10

0032

Stryker

5920-000-206

Fill set, quick to quick 10

0033

Stryker

5920-000-207

Fill set, quick to quick 20

0034

Stryker

5920-000-209

Y-fill set, quick to quick 10

0035

Stryker

5920-000-001

Extension tubing 40, single luer lock

0036

Stryker

5920-000-002

Extension tubing 40, single quick connect

0037

Stryker

5920-000-003

Extension tubing 60, single luer lock

0038

Stryker

5920-000-004

Extension tubing 60, single quick connect

0039

Stryker

5920-000-005

Extension tubing set 40, single luer lock

0040

Stryker

5920-000-006

Extension tubing set 40, quick connect

0041

Stryker

5920-000-007

Extension tubing set 60, luer lock

0042

Stryker

5920-000-008

Extension tubing set 60, quick connect

0043

Stryker

5920-000-101

Protective sleeve 4x8 (sterile, 10/pkg)

0044

Stryker

5920-000-102

Protective sleeve 6x9 (sterile, 10/pkg)

0045

Stryker

5920-000-103

Protective sleeve 4x8 (50/pkg)

0046

Stryker

5920-000-104

Protective sleeve 6x9 (50/pkg)

0047

Stryker

5920-000-201

10 luer lock to quick lock

0048

Stryker

5920-000-202

10 quick lock to luer lock

0049

Stryker

5920-000-205

10 fill set, luer lock to quick lock

0050

Stryker

5920-000-208

10 Y-fill set, quick lock to luer lock

0051

Stryker

5920-000-301

Adapter single, quick lock to luer lock

0052

Stryker

5920-000-302

Y Adaptor, single, luer lock to luer lock

0053

Stryker

5920-000-303

Y Adaptor, single, quick lock to luer lock

0054

Stryker

5920-000-305

Adapter set, quick lock to luer lock

0055

Stryker

5920-000-306

Y Adapter set, quick lock to luer lock

0056

Stryker

5920-000-307

Y Adapter set, quick lock to quick lock

The Department of Veterans Affairs (VA) is seeking vendors who can provide Stryker® Tourniquets: Pneumatic as listed above or equal commodities which meet all of the following salient characteristics. Vendors may quote any product solution or configuration so long as they meet the salient characteristics. The Government intends for offerors to include all ancillary items, to ensure the equipment can function as designed by the OEM and as clinically required. Products quoted in the technical volume must be captured on the Vendor s pricing volume (Attachment A - Price Cost Schedule) of the solicitation.

Additionally, responses can include any additional product and other product-related services necessary to obtain the supplies as required that may be beneficial and essential to the functionality of the proposed solution. These items must be clearly identified by brand name and part number.

When offerors include their additional proposed product items/services, these items may be considered for evaluation, and must be captured in the vendor s pricing volume with an estimated quantity of zero.

CLIN s 0001-0056 apply to the following SC s.

SC #

SALIENT

CHARACTERISTICS

METHOD OF EVALUATION

PAGE # WHERE are the

SC located IN TECHNICAL

LITERATURE

SC 1

Must provide a single and/or dual port/channel option

Literature Review

SC 2

Must provide a minimum/maximum pressure range, mmHg

within 100 450

Literature Review

SC 3

Must have a procedure time setting feature for up to 240 minutes

Literature Review

SC4

Must have battery backup with 5 hours minimum life

Literature Review

SC 5

Must offer Touchscreen interface LED or LCD

Literature Review

SC 6

Must have audio and visual alarms

Literature Review

SC 7

Must have cuff leak detection

Literature Review

SC 8

Must support table or pole mount

Literature Review

SC 9

Control unit must perform self-calibration checks and digitally display elapsed inflation time

Literature Review

Vendors may quote any product solution or configuration so long as they meet the salient characteristics. Products quoted in the technical volume must be captured on the Vendor s pricing volume (Attachment A, Price Cost Schedule) of the solicitation. Vendors may quote any additional ancillary products which they deem to be essential to the functionality of the proposed solution; these items must be captured in the Vendor s pricing volume with a quantity of zero.

The following attachments are incorporated by reference. All criteria outlined in the attachments are applicable to this combined synopsis/solicitation.

Files

Notice history

Notice Type Posted
6515--NX EQ Tourniquets: Pneumatic (VA-24-00028515) Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Tourniquet,nonpneumat Medical Supply Chain Total Small Business
METRx Instruments OR EQUAL San Francisco, California 94121, United States · NAICS 339112 Veterans Integrated Service Network 21 Total Small Business
6515--Source Sought Notice ^Stryker Stretcher Overton Brooks Va Medical Center 510 East Stoner Ave Shreveport LA 71101 · NAICS 339112 Veterans Integrated Service Network 16 Total Small Business
J065--Copy of FY26: MBC Sternudrive LiteTM; Model MBC 709-Modular Department of Veterans Affairs VA Caribbean Healthcare System San Juan PR 00921 · NAICS 339112 Veterans Integrated Service Network 8 No set-aside
6695--surgery globus instrument set Department of Veteran's Affairs Oklahoma City Va Health Care System Oklahoma City OK 73104, United States · NAICS 339112 Veterans Integrated Service Network 19 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors