The file's text, extracted by GovTribe without its formatting.
Combined Synopsis/Solicitation Notice
Combined Synopsis/Solicitation Notice
| SUBJECT* |
| NX EQ Tourniquets: Pneumatic (36C10G24Q0120) |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 22408-2697 |
| SOLICITATION NUMBER* |
| 36C10G24Q0120 |
| RESPONSE DATE/TIME/ZONE |
| 05-21-2024 11:59PM EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| CONTRACTING OFFICE ADDRESS |
| U.S. Department of Veterans Affairs |
OPAL | Strategic Acquisition Center
10300 Spotsylvania Ave | STE 400 Fredericksburg VA 22408-2697
POINT OF CONTACT*
Contracting Specialist Alanna Wilson Alanna.Wilson@va.gov 202-316-4366
PLACE OF PERFORMANCE
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/opal/sac/index.asp |
| URL DESCRIPTION |
| To learn more about SAC and its mission, please click here |
| AGENCY CONTACT’S EMAIL ADDRESS |
| Alanna.Wilson@va.gov |
| EMAIL DESCRIPTION |
| Alanna.Wilson@va.gov |
DESCRIPTION
| *= Required Field |
| Combined Synopsis/Solicitation Notice |
Combined Synopsis/Solicitation Notice
Solicitation Number:
36C10G24Q0120 Notice Type:
COMBINED SYNOPSIS/SOLICITATION
This is a combined synopsis/solicitation for brand name or equal commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, “Streamlined Procedures for Evaluation and Solicitation for Commercial Items,” as supplemented with additional information included in this notice.
This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued.
Solicitation number 36C10G24Q0120 is issued for this combined synopsis/solicitation; this solicitation is being issued as a Request for Quote (RFQ). This combined synopsis/solicitation incorporates provisions and clauses in effect through Federal Acquisition Regulation; Federal Acquisition Circular (FAC) FAC 2024-04, 05/01/2024.
Requirement Description:
The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Tourniquets: Pneumatic product line as a candidate for a VA-wide (otherwise referred to as “national”) single Requirements contract award.
Tourniquets: Pneumatic, are designed to circumferentially constrict/compress an extremity for a limited period of time by applying a precise amount of pressure using an automated gas-inflated cuff. The pressure is applied upon the limb surface and underlying tissues using the cuff; pressure is then transferred to the blood vessels causing a temporary occlusion. Pneumatic tourniquets are used mainly during surgical procedures on the extremities enabling surgeons to perform procedures in bloodless operative fields.
A single award Requirements contract will be awarded IAW FAR 52.211-6 Brand Name or Equal in accordance with all terms, conditions, provisions, specifications, and schedule of this solicitation herein. Quotes shall contain the terms for cost/price and technical capabilities of the brand name or equal equipment. The Government reserves the right to award without discussions.
The associated North American Industrial Classification System (NAICS) code for this procurement is 339112 – Surgical and Medical Instrument Manufacturing: Medical and Surgical Instruments, Equipment, and Supplies. and the associated size standard is 1,000 employees. This procurement action is issued as full and open.
This acquisition is for a single award Requirements contract in accordance with FAR Part 16.5 for Tourniquets: Pneumatic as identified in ATTACHMENT A – PRICE COST SCHEDULE – NX EQ Tourniquets: Pneumatic. All interested companies shall provide a quote for all Contract Line-Item Numbers (CLINs) listed in ATTACHMENT A – PRICE COST SCHEDULE – NX EQ Tourniquets: Pneumatic.
The ordering period is for one 12-month base year with four 12-month option years. Delivery is FOB destination. Firm-Fixed Price Orders will be placed against this contract in writing and will provide the delivery locations, delivery dates and exact quantities.
The FAR provision at 52.212-1, Instructions to Offerors – Commercial, applies to this acquisition including attached addenda to the provision.
The FAR provision at 52.212-2, Evaluation -- Commercial Items, and the specific evaluation criteria as attached addenda also apply to this acquisition.
The Offeror is to include a completed copy of the provision at 52.212-3, Offeror Representations and Certifications -- Commercial Items, with its offer.
Clause at 52.212-4, Contract Terms and Conditions -- Commercial Items, applies to this acquisition and a statement regarding any addenda to the clause. Addendum is attached.
Clause at 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders -- Commercial Items, applies to this acquisition and a statement regarding which, if any, of the additional FAR clauses cited in the clause are applicable to the acquisition. Addendum is attached.
All interested quoters must be registered in the System for Award Management (SAM) prior to submitting a quote. You may access SAM at https://sam.gov/SAM/.
All questions regarding this combined synopsis/solicitation are due via email by 11:59PM EST on May 15th, 2024, to Contract Specialist, Alanna Wilson, Alanna.Wilson@va.gov and Contracting Officer, Sara Vickroy at Sara.Vickroy@va.gov. No calls will be accepted.
Quotes are due via email by 11:59PM EST on May 21st, 2024, to Contract Specialist, Alanna Wilson, Alanna.Wilson@va.gov and Contracting Officer, Sara Vickroy at Sara.Vickroy@va.gov.
1. SCOPE OF WORK:
The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Tourniquets: Pneumatic product line as a candidate for a VA-wide (otherwise referred to as “national”) single Requirements contract award.
Tourniquets: Pneumatic, are designed to circumferentially constrict/compress an extremity for a limited period of time by applying a precise amount of pressure using an automated gas-inflated cuff. The pressure is applied upon the limb surface and underlying tissues using the cuff; pressure is then transferred to the blood vessels causing a temporary occlusion. Pneumatic tourniquets are used mainly during surgical procedures on the extremities enabling surgeons to perform procedures in bloodless operative fields.
The Contractor must demonstrate the ability to meet all requirements for the solicitation. The objective is to provide Tourniquets: Pneumatic to be used by clinicians throughout the VA medical centers and facilities. The period of performance is for one (1) 12-month base period with four (4) twelve (12) month option periods.
2. REQUIREMENT
This requirement will be IAW FAR clause 52.211-6, “Brand Name or Equal” which requires the quoter indicate that each product being offered as an “equal” product to the Stryker® Tourniquets: Pneumatic. For each equal Tourniquets: Pneumatic product, the offeror must include a description reflecting the salient characteristics (SC) and level of quality that will satisfy the salient physical, functional, or performance characteristics of the equal product(s) specified in the solicitation. The quoter must also clearly identify the item by brand name (if any) and make/model number. Finally, the quoter must include descriptive literature, such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the contracting officer, and clearly describe any modifications it plans to make to a product to make it conform to the solicitation requirements.
The following line items comprise the Tourniquets: Pneumatic Product Line:
Contract Line Items
| Manufacture |
| Part Number |
| Description |
| 0001 |
| Stryker |
| 5920-011-000 |
| SmartPump Dual Channel |
| 0002 |
| Stryker |
| 5920-013-000 |
| SmartPump Rolling Stand |
| 0003 |
| Stryker |
| 5921-109-135 |
| Disp. 9x1.75, 1Bla, 1Prt, Quick Connect |
| 0004 |
| Stryker |
| 5921-209-135 |
| Disp. 9x2.75, 1Bla, 1Prt, Quick Connect |
| 0005 |
| Stryker |
| 5921-112-135 |
| Disp. 12x2, 1Bla, 1Prt, Quick Connect |
| 0006 |
| Stryker |
| 5921-212-135 |
| Disp. 12x3.5, 1Bla, 1Prt, Quick Connect |
| 0007 |
| Stryker |
| 5921-115-135 |
| Disp. 15x2.5, 1Bla, 1Prt, Quick Connect |
| 0008 |
| Stryker |
| 5921-018-135 |
| Disp. 18x3, 1Bla, 1Prt, Quick Connect |
| 0009 |
| Stryker |
| 5921-218-135 |
| Disp. 18x4, 1Bla, 1Prt, Quick Connect |
| 0010 |
| Stryker |
| 5921-024-135 |
| Disp. 24x4, 1Bla, 1Prt, Quick Connect |
| 0011 |
| Stryker |
| 5921-030-135 |
| Disp. 30x4, 1Bla, 1Prt, Quick Connect |
| 0012 |
| Stryker |
| 5921-034-135 |
| Disp. 34x4, 1Bla, 1Prt, Quick Connect |
| 0013 |
| Stryker |
| 5921-044-135 |
| Disp. 44x4, 1Bla, 1Prt, Quick Connect |
| 0014 |
| Stryker |
| 5921-112-235 |
| Disp. 12x2, 1Bla, 2Prt, Quick Connect |
| 0015 |
| Stryker |
| 5921-212-235 |
| Disp. 12x3.5, 1Bla, 2Prt, Quick Connect |
| 0016 |
| Stryker |
| 5921-115-235 |
| Disp. 15x2.5, 1Bla, 2Prt, Quick Connect |
| 0017 |
| Stryker |
| 5921-018-235 |
| Disp. 18x3, 1Bla, 2Prt, Quick Connect |
| 0018 |
| Stryker |
| 5921-218-235 |
| Disp. 18x4, 1Bla, 2Prt, Quick Connect |
| 0019 |
| Stryker |
| 5921-034-235 |
| Disp. 34x4, 1Bla, 2Prt, Quick Connect |
| 0020 |
| Stryker |
| 5921-044-235 |
| Disp. 44x4, 1Bla, 2Prt, Quick Connect |
| 0021 |
| Stryker |
| 5921-018-245 |
| Disp. 18x5.5, 2Bla, 2Prt, Quick Connect |
| 0022 |
| Stryker |
| 5921-024-235 |
| Disp. 24x4, 1Bla, 2Prt, Quick Connect |
| 0023 |
| Stryker |
| 5921-018-145 |
| Disp. 18x5.5, 2Bla, 1Prt, Quick Connect |
| 0024 |
| Stryker |
| 5921-024-145 |
| Disp. 24x5.5, 2Bla, 1Prt, Quick Connect |
| 0025 |
| Stryker |
| 5921-109-235 |
| Disp. 9x1.75, 1Bla, 2Prt, Quick Connect |
| 0026 |
| Stryker |
| 5921-209-235 |
| Disp. 9x2.75, 1Bla, 2Prt, Quick Connect |
| 0027 |
| Stryker |
| 5921-030-235 |
| Disp. 30x4, 1Bla, 2Prt, Quick Connect |
| 0028 |
| Stryker |
| 5921-024-245 |
| Disp. 24x5.5, 2Bla, 2Prt, Quick Connect |
| 0029 |
| Stryker |
| 5920-000-304 |
| Y Adaptor |
| 0030 |
| Stryker |
| 5920-000-203 |
| quick lock to quick lock |
| 0031 |
| Stryker |
| 5920-000-204 |
| Y-fill, quick to quick 10 |
| 0032 |
| Stryker |
| 5920-000-206 |
| Fill set, quick to quick 10 |
| 0033 |
| Stryker |
| 5920-000-207 |
| Fill set, quick to quick 20 |
| 0034 |
| Stryker |
| 5920-000-209 |
| Y-fill set, quick to quick 10 |
| 0035 |
| Stryker |
| 5920-000-001 |
| Extension tubing 40, single luer lock |
| 0036 |
| Stryker |
| 5920-000-002 |
| Extension tubing 40, single quick connect |
| 0037 |
| Stryker |
| 5920-000-003 |
| Extension tubing 60, single luer lock |
| 0038 |
| Stryker |
| 5920-000-004 |
| Extension tubing 60, single quick connect |
| 0039 |
| Stryker |
| 5920-000-005 |
| Extension tubing set 40, single luer lock |
| 0040 |
| Stryker |
| 5920-000-006 |
| Extension tubing set 40, quick connect |
| 0041 |
| Stryker |
| 5920-000-007 |
| Extension tubing set 60, luer lock |
| 0042 |
| Stryker |
| 5920-000-008 |
| Extension tubing set 60, quick connect |
| 0043 |
| Stryker |
| 5920-000-101 |
| Protective sleeve 4x8 (sterile, 10/pkg) |
| 0044 |
| Stryker |
| 5920-000-102 |
| Protective sleeve 6x9 (sterile, 10/pkg) |
| 0045 |
| Stryker |
| 5920-000-103 |
| Protective sleeve 4x8 (50/pkg) |
| 0046 |
| Stryker |
| 5920-000-104 |
| Protective sleeve 6x9 (50/pkg) |
| 0047 |
| Stryker |
| 5920-000-201 |
| 10 luer lock to quick lock |
| 0048 |
| Stryker |
| 5920-000-202 |
| 10 quick lock to luer lock |
| 0049 |
| Stryker |
| 5920-000-205 |
| 10 fill set, luer lock to quick lock |
| 0050 |
| Stryker |
| 5920-000-208 |
| 10 Y-fill set, quick lock to luer lock |
| 0051 |
| Stryker |
| 5920-000-301 |
| Adapter single, quick lock to luer lock |
| 0052 |
| Stryker |
| 5920-000-302 |
| Y Adaptor, single, luer lock to luer lock |
| 0053 |
| Stryker |
| 5920-000-303 |
| Y Adaptor, single, quick lock to luer lock |
| 0054 |
| Stryker |
| 5920-000-305 |
| Adapter set, quick lock to luer lock |
| 0055 |
| Stryker |
| 5920-000-306 |
| Y Adapter set, quick lock to luer lock |
| 0056 |
| Stryker |
| 5920-000-307 |
| Y Adapter set, quick lock to quick lock |
The Department of Veterans Affairs (VA) is seeking vendors who can provide Stryker® Tourniquets: Pneumatic as listed above or equal commodities which meet all of the following salient characteristics. Vendors may quote any product solution or configuration so long as they meet the salient characteristics. The Government intends for offerors to include all ancillary items, to ensure the equipment can function as designed by the OEM and as clinically required. Products quoted in the technical volume must be captured on the Vendor’s pricing volume (Attachment A - Price Cost Schedule) of the solicitation.
Additionally, responses can include any additional product and other product-related services necessary to obtain the supplies as required that may be beneficial and essential to the functionality of the proposed solution. These items must be clearly identified by brand name and part number.
When offerors include their additional proposed product items/services, these items may be considered for evaluation, and must be captured in the vendor’s pricing volume with an estimated quantity of zero.
CLIN’s 0001-0056 apply to the following SC’s.
CHARACTERISTICS
| METHOD OF EVALUATION |
| PAGE # WHERE are the |
SC located IN TECHNICAL
LITERATURE
| SC 1 |
| Must provide a single and/or dual port/channel option |
| Literature Review |
| SC 2 |
| Must provide a minimum/maximum pressure range, mmHg |
within 100 – 450
Literature Review
| SC 3 |
| Must have a procedure time setting feature for up to 240 minutes |
Literature Review
| SC4 |
| Must have battery backup with 5 hours minimum life |
| Literature Review |
| SC 5 |
| Must offer Touchscreen interface – LED or LCD |
| Literature Review |
| SC 6 |
| Must have audio and visual alarms |
| Literature Review |
| SC 7 |
| Must have cuff leak detection |
| Literature Review |
| SC 8 |
| Must support table or pole mount |
| Literature Review |
| SC 9 |
| Control unit must perform self-calibration checks and digitally display elapsed inflation time |
| Literature Review |
Vendors may quote any product solution or configuration so long as they meet the salient characteristics. Products quoted in the technical volume must be captured on the Vendor’s pricing volume (Attachment A, Price Cost Schedule) of the solicitation. Vendors may quote any additional ancillary products which they deem to be essential to the functionality of the proposed solution; these items must be captured in the Vendor’s pricing volume with a quantity of zero.
The following attachments are incorporated by reference. All criteria outlined in the attachments are applicable to this combined synopsis/solicitation.
See attached document: ATTACHMENT A PRICE COST SCHEDULE NX EQ Tourniquets Pneumatic.
See attached document: ATTACHMENT B - CONTRACT ADMINISTRATION - Tourniquets Pneumatic.
See attached document: ATTACHMENT C - CONTRACT CLAUSES - NX EQ Tourniquets Pneumatic.
See attached document: ATTACHMENT D - SOLICITATION PROVISIONS - NX EQ Tourniquets Pneumatic.
See attached document: ATTACHMENT E - REPORTING TOOL - NX EQ Tourniquets Pneumatic.
Combined Synopsis/Solicitation Notice
Page 1 of Combined Synopsis/Solicitation Notice