6515--Mobile Radiation Shielding
Award Notice Posted
- Solicitation number
- 36C24826AP4397
- Agency
-
Veterans Integrated Service Network 8
Veterans Health Administration, Department of Veterans Affairs
- Awarded
- to Lovell Government Services Inc.
- Set-aside
- No set-aside
Opportunity facts
- Contract number
- 36F79725D012836C24826F0236 Federal contract award
- NAICS code
- 339112 Surgical and Medical Instrument Manufacturing
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8 awarded $250,799.39 to Lovell Government Services Inc. for mobile radiation shielding systems on August 17, 2026.
The award supplies James A. Haley Veterans Hospital in Tampa, Florida with Rampart Guardian Rover and Rampart IC Sentry radiation shielding equipment for use in the Cardiology Department's Cardiac Catheterization Labs. The Guardian Rover features acrylic panels with 1.0mm lead-equivalent protection on a three-panel system with lockable casters (under 330 lbs), rechargeable battery-operated positioning, and sterile pliable radiation curtains with IPX6 washability. The Sentry system provides 0.5mm lead-equivalent protection, adjusts to 72 inches height and 26 inches width, includes lockable casters and ergonomic single-handed handle, weighing up to 115 pounds. The contractor delivers, assembles, and installs the equipment; standard manufacturer warranty is included. Award was made under sole-source authority (41 USC 3304(a)(5) and 38 U.S. Code 8127(c)) to a certified service-disabled veteran-owned small business on the GSA Federal Supply Schedule. Place of performance is Tampa, Florida. Product service code is 6515; NAICS is 339112.
Notice text
Statement of Need
Radiation Shielding Systems
GENERAL: James A. Haley Veterans Hospital (JAHVH) located at 13000 Bruce B. Downs Blvd, Tampa, FL 33612, has a requirement for RAMPART GUARDIAN ROVER and RAMPART IC SENTRY (BRAND NAME) to house and provide mobile radiation protection without the need for cumbersome lead vests during Cardiac Catheterization procedures in Cardiology Section of Medicine and Specialty Care.
BACKGROUND: JAHVH currently provides patient care for veteran patients in the Cardiac Catheterization Labs of Cardiology Department Medicine and Specialty Care Service. In these Cardiac Catheterization Labs, the clinicians performing the procedure wear the typical bulky lead vests.
PURPOSE: The requested radiation shielding systems would remove the need for clinicians to wear the bulky lead vests, providing more mobility which will lead to better quality care and efficient procedures.
SCOPE: Vendor shall provide RAMPART GUARDIAN ROVER and RAMPART IC SENTRY radiation shields (BRAND NAME) that meets the physical, functional and performance of the listed salient characteristics in this section. The equipment feature is essential to the technical requirements to meet the needs of the government.
CHARACTERISTICS:
Rampart GUARDIAN ROVER
Acrylic panels with 1.0mm of lead-equivalent protection
Three panel system on smooth rolling, lockable casters that can be manipulated in position and orientation weighing under 330lbs
Rechargeable battery-operated system for positioning adjustments
Pliable radiation curtains that extend the coverage area, can be stored when not needed and are fully sterile
IPX6 Protection Class for Washable
Rampart SENTRY
0.5mm lead-equivalent protection that is height adjustable up to 72 and up to 26 wide
Pliable soft shielding material
Lockable caster wheels for smooth placement maneuvering and stationary placement when needed
Low profile base and wheel system for tip-over/tripping protection
Ergonomic handle for one-handed maneuvering
Maximum weight of 115lbs for ease of movement
SOFTWARE: There are no software requirements or compatibility needs regarding this request.
INSTALLATION: Vendor will provide delivery and assembly/installation of the shielding systems in the Cardiac Catheterization Lab located within James A. Haley VA Hospital at 13000 Bruce B. Downs Blvd., Tampa FL 33612.
TRAINING: Government will not require additional training.
WARRANTY OF EQUIPMENT: Vendor shall provide standard manufacturer industry warranty term. Government does not accept extended warranty, which requires advance payment. Awarded contract 36F79725D012836C24826F0236 to LOVELL GOVERNMENT SERVICES INC. for 250799.39 on 2026-08-17.