This is an Award Notice for a mobile radiation shielding systems contract awarded by the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 8 (VA Network Contracting Office 8). The award was made to Lovell Government Services Inc. (UEI: MNH3STM1FTS6) located in Pensacola, Florida, on August 17, 2026, with a total award amount of $250,799.39 under solicitation number 36C24826-AP-4397.

James A. Haley Veterans' Hospital in Tampa, Florida, required Rampart Guardian Rover and Rampart IC Sentry brand radiation shielding systems to eliminate the need for clinicians to wear bulky lead vests during Cardiac Catheterization procedures in the Cardiology Department. The Rampart Guardian Rover system features acrylic panels with 1.0mm lead-equivalent protection, a three-panel configuration on lockable casters weighing under 330 pounds, rechargeable battery-operated positioning controls, and sterile pliable radiation curtains with IPX6 protection class. The Rampart IC Sentry system provides 0.5mm lead-equivalent protection, adjusts up to 72 inches in height and 26 inches in width, includes lockable casters, low-profile base design for safety, and an ergonomic single-handed handle, with a maximum weight of 115 pounds. The contractor is responsible for delivery, assembly, and installation at the hospital location. The contract includes standard manufacturer industry warranty; extended warranties requiring advance payment are not accepted. The product service code is 6515 (surgical instruments and supplies), and the NAICS code is 339112 (surgical instrument manufacturing).

View the file

Other files

File Type Posted
P03 RFO 8_SSJ GSAM 538.7104-3b Redacted.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Award Notice

SUBJECT*
Mobile Radiation Shielding

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
33637
SOLICITATION NUMBER*
36C248-26-AP-4397

BASE NOTICE TYPE

ARCHIVE
30 DAYS AFTER THE AWARD DATE
RECOVERY ACT FUNDS
N
PRODUCT SERVICE CODE*
6515
NAICS CODE*
339112

SET-ASIDE

CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 8 (NCO 8)

8875 Hidden River Pkwy Ste 160A Tampa FL 33637

POINT OF CONTACT*

Contract Specialist David Griganavicius david.griganavicius@va.gov 813-796-2945

AWARD INFORMATION

AWARD NUMBER*
36F79725D0128 36C24826F0236
AWARD AMOUNT*
$250,799.39
LINE ITEM NUMBER
0001-0004
AWARD DATE (MM-DD-YYYY)*
08-17-2026
AWARDEE NAME*
LOVELL GOVERNMENT SERVICES INC.
CONTRACTOR’S UEI
MNH3STM1FTS6

AWARDEE ADDRESS LINE 1*

AWARDEE ADDRESS LINE 2*

AWARDEE ADDRESS LINE 3*
223 W GREGORY ST

AWARDEE ADDRESS LINE 4*

AWARDEE CITY
PENSACOLA
AWARDEE STATE
FL
AWARDEE ZIP CODE
32502

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov
URL DESCRIPTION
Department of Veterans Affairs

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

Statement of Need

Radiation Shielding Systems

GENERAL: James A. Haley Veterans’ Hospital (JAHVH) located at 13000 Bruce B. Downs Blvd, Tampa, FL 33612, has a requirement for RAMPART GUARDIAN ROVER and RAMPART IC SENTRY (BRAND NAME) to house and provide mobile radiation protection without the need for cumbersome lead vests during Cardiac Catheterization procedures in Cardiology Section of Medicine and Specialty Care.

BACKGROUND: JAHVH currently provides patient care for veteran patients in the Cardiac Catheterization Labs of Cardiology Department – Medicine and Specialty Care Service. In these Cardiac Catheterization Labs, the clinicians performing the procedure wear the typical bulky lead vests.

PURPOSE: The requested radiation shielding systems would remove the need for clinicians to wear the bulky lead vests, providing more mobility which will lead to better quality care and efficient procedures.

SCOPE: Vendor shall provide RAMPART GUARDIAN ROVER and RAMPART IC SENTRY radiation shields (BRAND NAME) that meets the physical, functional and performance of the listed salient characteristics in this section. The equipment feature is essential to the technical requirements to meet the needs of the government.

CHARACTERISTICS:

Rampart GUARDIAN ROVER

· Acrylic panels with 1.0mm of lead-equivalent protection

· Three panel system on smooth rolling, lockable casters that can be manipulated in position and orientation weighing under 330lbs

· Rechargeable battery-operated system for positioning adjustments

· Pliable radiation curtains that extend the coverage area, can be stored when not needed and are fully sterile

· IPX6 Protection Class for Washable

Rampart SENTRY

· 0.5mm lead-equivalent protection that is height adjustable up to 72” and up to 26” wide

· Pliable soft shielding material

· Lockable caster wheels for smooth placement maneuvering and stationary placement when needed

· Low profile base and wheel system for tip-over/tripping protection

· Ergonomic handle for one-handed maneuvering

· Maximum weight of 115lbs for ease of movement

SOFTWARE: There are no software requirements or compatibility needs regarding this request.

INSTALLATION: Vendor will provide delivery and assembly/installation of the shielding systems in the Cardiac Catheterization Lab located within James A. Haley VA Hospital at 13000 Bruce B. Downs Blvd., Tampa FL 33612.

TRAINING: Government will not require additional training.

WARRANTY OF EQUIPMENT: Vendor shall provide standard manufacturer industry warranty term. Government does not accept extended warranty, which requires advance payment.