6515--InBody Composition Analysis Scale *BRAND NAME OR EQUAL*

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
36C25726Q0622
Agency
Veterans Integrated Service Network 17 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
339112 Surgical and Medical Instrument Manufacturing
PSC
6515 Medical And Surgical Instruments, Equipment, And Supplies
Place of performance
Department of Veterans Affairs VA Harlingen Medical HealthCare Center Harlingen, Texas 78550, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Integrated Service Network 17 is conducting market research to identify qualified vendors capable of providing an InBody 380 Body Composition Analyzer or an equal product, with responses due by June 24, 2026. This is a sources sought notice for information-gathering purposes only and does not constitute a solicitation, commitment to purchase, or promise to issue a future RFQ, IFB, or RFP; the VA will not accept unsolicited proposals or reimburse response costs.

The device will be deployed at the VA Harlingen Medical HealthCare Center in Harlingen, Texas. The equipment must utilize Direct Segmental Multi-Frequency Bioelectrical Impedance Analysis technology and complete testing in 90 seconds or less. Required measurement parameters include weight, skeletal muscle mass, body fat mass, percent body fat, BMI, BMR, total and segmented body water, segmental lean and fat analysis, and visceral fat assessment. The device must support data export via USB or Bluetooth, accommodate weights up to 330 pounds, feature a stable platform with integrated hand electrodes, be FDA-registered or compliant, meet applicable electrical and safety standards, and carry a minimum one-year manufacturer warranty.

Vendors should submit company information, socioeconomic status, capability statements, technical documentation addressing each salient characteristic, product literature, delivery timeframe, applicable contract vehicles (GSA, SEWP, VA FSS), and warranty information to matthew.lee5@va.gov and tommy.haire@va.gov by June 24, 2026 at 11:00 PM Central Time. The anticipated NAICS code is 339112; the PSC is 6515.

Notice text

Sources Sought Notice

Sources Sought Notice

Page 5 of 5

SOURCES SOUGHT NOTICE

*= Required Field

Sources Sought Notice

Page 1 of 5

THIS NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES - it does not constitute a Request for Quote (RFQ)/Invitation for Bid (IFB)/Request for Proposal (RFP) or a promise to issue an RFQ, IFB or RFP in the future. This notice does not commit the VA to contract for any supply or service. Further, the VA is not seeking quotes, bids or proposals at this time and will not accept unsolicited proposals in response to this source sought notice. The VA will not pay for any information or administrative costs incurred in response to this notice. Submittals will not be returned to the responder. Not responding to this notice does not preclude participation in any future RFQ or IFB or RFP, if any is issued. If a solicitation is released, it will be synopsized on the Governmentwide Point of Entry. It is the responsibility of potential offerors to monitor the Governmentwide Point of Entry for additional information pertaining to this requirement. The anticipated NAICS code is: 339112.

SOURCES SOUGHT NOTICE

InBody 380 Body Composition Analyzer

1. PURPOSE

This Sources Sought Notice is issued solely for market research and information-gathering purposes. It does not constitute a solicitation, commitment, or authorization to procure any supplies or services. The Government is seeking to identify qualified and capable vendors that can provide the InBody 380 Body Composition Analyzer or an equal product that meets all salient characteristics listed below.

2. BACKGROUND

The Government has a requirement for a professional-grade body composition analyzer for use in clinical, wellness, or research environments. The device must provide accurate, quick, and noninvasive assessment of body composition metrics used in patient evaluation and treatment planning.

3. REQUIRED ITEM

Brand Name: InBody 380 Body Composition Analyzer

OR EQUAL: Vendors may offer an equivalent product, provided the item meets or exceeds all salient characteristics included in Section 4.

4. SALIENT CHARACTERISTICS (Minimum Requirements)

Any offered product must meet all of the following:

Measurement Technology

Utilizes Direct Segmental Multi Frequency Bioelectrical Impedance Analysis (DSM BIA)

Employs multiple frequencies for increased accuracy

Provides non invasive, rapid testing without the use of empirical estimation formulas

Measurement Parameters (minimum required)

Weight

Skeletal Muscle Mass

Body Fat Mass

Percent Body Fat

Body Mass Index (BMI)

Basal Metabolic Rate (BMR)

Total Body Water, Intracellular Water, and Extracellular Water

Segmental Lean Analysis (right arm, left arm, trunk, right leg, left leg)

Segmental Fat Analysis

Visceral Fat or comparable abdominal fat assessment

Impedance values at multiple frequencies for each segment

Operational Requirements

Test duration: 90 seconds or less

User-friendly interface with onboard screen

Ability to output full results sheet to printer or computer

Ability to store or export data through USB, Bluetooth, or software interface

Weight capacity: Minimum 330 lb. (150 kg)

Accuracy suitable for clinical or research use

Powered by standard AC adapter

Physical & Durability Requirements

Stable platform with integrated hand electrodes

Compact, portable, and appropriate for clinical environments

Minimum 1 year manufacturer warranty

Standards & Compliance

FDA registered or compliant medical device

Must comply with all applicable electrical and safety standards

5. REQUESTED INFORMATION FROM INTERESTED VENDORS

Vendors responding to this notice should submit the following:

Company information (name, address, UEI, POC).

Socioeconomic status (SB, WOSB, SDVOSB, 8(a), HUBZone, etc.).

Capability statement addressing ability to meet requirements.

Technical documentation showing how proposed equipment meets each salient characteristic.

Product literature for the proposed brand name or equal device.

Estimated delivery timeframe.

Applicable contract vehicles (GSA, SEWP, VA FSS, etc.).

Warranty information.

6. SUBMISSION DETAILS

All responses must be submitted electronically via email to:

Contract Specialist: Matthew.Lee5@va.gov Contract Officer: Tommy.Haire@va.gov

Subject line: Sources Sought InBody 380 Body Composition Analyzer

Responses requested no later than: June 24, 2026

7. DISCLAIMER

This notice is not a solicitation. The Government will not pay for any information received in response to this notice and will not reimburse any costs associated with preparing or submitting responses. The results of this Sources Sought may influence the acquisition strategy for any future solicitation.

End of Document

Attachments

Files attached to this notice, newest first
File Type Posted
Sources Sought-36C25726Q06 22 InBody Composition Analysis Scale.pdf PDF
36C25726Q0622.docx DOCX document

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
6515--Body Composition Analysis Scale Award Award Notice
6515--InBody Composition Analysis Scale *BRAND NAME ONLY Latest solicitation Solicitation
6515--InBody Composition Analysis Scale *BRAND NAME OR EQUAL* This notice · Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity