5996--Paging System RFI NYQUIST SYSTEM Brand or Equal

Closed Pre-Solicitation Posted

Solicitation number
36C24226Q0730
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

PSC
5996 Amplifiers
Place of performance
VA New Jersey Healthcare System Lyons, New Jersey 07939, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs, Veterans Integrated Service Network 2 is issuing a sources-sought notice for a paging system replacement at the VA New Jersey Healthcare System's Lyons campus, with responses due July 21, 2026. This is a brand-or-equal procurement specified as Bogen Nyquist equipment, no set-aside.

Place of performance is VA New Jersey Healthcare System, 151 Knollcroft Road, Lyons, New Jersey 07939.

The requirement includes removal and disposal of the existing non-working paging system, amplifiers, and interfacing systems in Building 57, followed by installation of one Nyquist System Controller (Part# NQ-SYSCTRL), two Nyquist 4-Channel x 300W 2U Audio Power Amplifiers (Part# NQ-A4300), and one C4000 System Software License B1 (Part# NQ-C4000-B1) to the existing speaker system and network infrastructure. The contractor must program, test, and train VA staff on the newly installed system and ensure all floors of Building 57 receive proper coverage.

Work must be completed within 21 days of award, conducted between 7:00 AM and 4:30 PM on normal weekdays, excluding federal holidays. The contractor must follow Lockout/Tagout procedures and comply with VA, OSHA, and EPA safety policies. Work is firm-fixed-price.

Solicitation number is 36C24226Q0730. Contact: Barry Sawyer, Contract Specialist, Barry.Sawyer@va.gov.

Notice text

The VA New Jersey Healthcare System, Lyons campus is in need of a replacement paging system in Building 57.

This is a brand or equivalent requirement but must meet all the salient characteristics of the brand suggested.

The Following items need to be met by the vendor:

Vendor shall:

Vender will follow all Lock out / Tag out procedures as per the facilities guidelines ensuring potential emergency sources are secured.

Vender will remove the non-working paging system; Amplifiers, Standby Amplifiers or interfacing systems in building 57 and dispose of the same.

Vender will provide and install all new equipment listed below to the existing speaker system and network infrastructure that is established.

Vender will install, program, and test all equipment with VA staff to ensure proper working conditions of the paging systems on all floors of Bldg. 57.

Vender will train VA staff in the proper operation of the newly installed Bogen Nyquist paging system.

Note

Items to be installed as brand or equal:

NYQUIST SYSTEM CONTROLLER

(H/W ONLY) Part# NQ-SYSCTRL Qty-1

NYQUIST 4-CH x 300W 2U AUDIO

POWER AMP Part# NQ-A4300 Qty-2

C4000 SYS S/W LIC B1

Part# NQ-C4000-B1 Qty-1

Performance Period: : [Firm-Fixed-Price] The contractor shall complete the work required under this SOW within 21 day of this award unless otherwise directed by the Contracting Officer (CO). Work hours are between 7:00am and 4:30 pm on normal weekdays. Work on Federal Holidays is excluded from this contract.

- Upon Completion ensure that all debris is cleaned up and removed from VA premises by contractor.

- Contractor will follow all VA, OSHA, and EPA safety policies.

Files

File Type Posted
36C24226Q0730.docx DOCX document

Notice history

Notice Type Posted
This notice Latest pre-solicitation Pre-Solicitation
5996--Paging System RFI NYQUIST SYSTEM Brand or Equal Original Pre-Solicitation