4320--Condensate Pump Replacement

Closed Solicitation Posted

Solicitation number
36C24625Q0893
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6 is seeking to procure a condensate pump replacement system at the W. G. Hefner Medical Center in Salisbury, North Carolina. The project involves replacing the existing condensate system with a new duplex steam pressure powered pump package in Building 3's ground floor mechanical room, including isolation of the existing system, demolition and disposal of old equipment, installation of new piping, insulation, and comprehensive testing. The solicitation requires contractors to provide a complete skid package with specific technical parameters including maximum pressure of 200 psig, temperature rating of 400°F, 3-inch inlet, 2-inch outlet, and a minimum 57-gallon receiving tank. Evaluation will be based on technical approach, past performance, and price, with award going to the lowest-price technically acceptable offeror. A mandatory site visit is scheduled for July 31, 2025, at 9:00 AM EDT, with quotes due by August 8, 2025, at 10:00 AM EST.

This unrestricted solicitation does not utilize any set-aside designations and will be awarded as a firm-fixed-price contract. The project timeline requires completion no later than September 30, 2025, providing approximately two months for execution after the anticipated contract award. The work location is specifically at the W. G. Hefner Medical Center in Salisbury, North Carolina, with all activities centered on the ground floor mechanical room of Building 3. The scope includes complete replacement of a single condensate pump system rather than multiple units, indicating a focused mechanical upgrade project. While specific contract values are not disclosed in the solicitation documents, the project falls under NAICS code 238220 for Plumbing, Heating, and Air-Conditioning Contractors and PSC code 4320 for Power and Hand Pumps.

Notice text

INTENTIONALLY LEFT BLANK

Files

Notice history

Notice Type Posted
This notice Latest solicitation Solicitation
4320--Condensate Pump Replacement Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Replace Condensate Pressure Pump North Hills, California 91343, United States · NAICS 238990 Veterans Integrated Service Network 22 Service-Disabled Veteran-Owned Small Business
J041--Condensate Pump Replacement West Haven Vamc West Haven CT 06516 · NAICS 238220 Veterans Integrated Service Network 1 Service-Disabled Veteran-Owned Small Business
Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009) Veterans Affiars Medical Center Durham NC 27705 · NAICS 236220 Veterans Integrated Service Network 6 Service-Disabled Veteran-Owned Small Business
NTX VAMC Utility Tunnel Pump Room Dallas, Texas 75216, United States · NAICS 238220 Veterans Integrated Service Network 17 Service-Disabled Veteran-Owned Small Business
Z2NZ--Turn Key Chiller Equipment (Purchase and Install) Pineville, Louisiana 71360, United States · NAICS 238220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors