31100PR260000049 - FY 26-FY27 Elevator Monthly Service Contract

Closed Solicitation Posted

Solicitation number
31100PR260000049
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
San Pedro, California 90731, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Coast Guard seeks monthly preventative maintenance and annual inspection, certification, and testing services for a commercial elevator at USCG Base Los Angeles Long Beach, with proposals due July 10. This is a full and open competition with no set-aside.

Place of performance is Building 20 at 1001 South Seaside Avenue, San Pedro, California. The contractor shall conduct twelve monthly inspections scheduled for the second week of each month, including routine examination, adjustment, and lubrication of elevator components, plus one annual inspection and certification in accordance with the American National Standard Safety Code for Elevators and Escalators. Work shall be performed only between 7:30 AM and 3:30 PM, Monday through Friday (excluding Federal Holidays), with a Coast Guard Facilities department member present during all work. Contractor personnel must be directly employed, submit names to the Contracting Officer's Representative five days prior to commencing work for security clearance and background checks, and provide valid photo identification (California Real ID or valid passport) and proof of legal right to work in the United States.

Service Contract Act Labor Wage Rates for Los Angeles, California apply to all labor categories. The NAICS code is 811310, Commercial and Industrial Machinery and Equipment Repair and Maintenance; PSC is J035. Offerors must submit transparent cost breakdowns for CLIN 0001 (Monthly Preventative Maintenance, 12 months) and CLIN 0002 (Annual Inspection, Testing & Certification, 1 job), separating labor and material costs for each. The contractor must comply with OSHA Safety and Health Standards, California Construction Safety Orders, Army Corps of Engineers EM385-1-1, and submit an Accident Prevention/Safety Plan prior to work commencement.

Notice text

SOLICITATION DESCRIPTION:

1. GENERAL INFORMATION
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice.

  • Set-Aside: None (Full and Open Competition)

  • Location: USCG Base Los Angeles Long Beach, 1001 S. Seaside Ave., Building 20

2. STATEMENT OF WORK (SOW)
The Contractor shall provide all labor, materials, equipment, and supervision necessary to perform monthly preventative maintenance and a one-time annual inspection, certification, and testing for the commercial elevator located in Building 20.

A. Monthly Preventative Maintenance
Conduct twelve (12) monthly inspections, scheduled for the second week of each month. Inspections shall include routine examination, adjustment, and lubrication of elevator components subject to wear and tear under normal operating conditions.

B. Annual Inspection and Certification
Perform one (1) annual inspection and one (1) annual certification/testing of the elevator in accordance with the latest edition of the American National Standard Safety Code for Elevators and Escalators. This includes the evaluation of hydraulic systems, governors, safeties, and buffers.

C. Labor Regulations
The Service Contract Act (SCA) Labor Wage Rates for Los Angeles, California apply to all labor categories utilized under this contract.

3. BID PRICE BREAKDOWN REQUIREMENTS
For bid evaluation purposes, offerors must submit a transparent breakdown of labor and material costs. Submissions must include pricing for the following Contract Line Item Numbers (CLINs):

  • CLIN 0001: Monthly Preventative Maintenance (Base) - Qty: 12 Months. Provide breakdown of Labor Cost and Materials Cost.

  • CLIN 0002: Annual Inspection, Testing & Certification - Qty: 1 Job. Provide breakdown of Labor Cost and Materials Cost.

  • Total Evaluated Price: Combined Fixed-Price Proposal (CLIN 0001 + CLIN 0002).

4. EVALUATION FACTORS (FAR 52.212-2 Addendum)
The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. A Tradeoff Process will be used to determine Best Value.

The following factors shall be used to evaluate offers:

  1. Factor I: Technical Proficiency (Schedule & Reliability)

  2. Factor II: Past Performance

  3. Factor III: Price

Relative Importance:
Non-price factors (Technical Proficiency and Past Performance), when combined, are significantly more important than price. Among the non-price factors, Technical Proficiency is more important than Past Performance. The Government reserves the right to award to other than the lowest-priced offeror.

Evaluation Criteria Details:

  • Factor I - Technical Proficiency: Offerors must submit a detailed execution plan demonstrating their technical capability to reliably adhere to the schedule, specifically hitting the required "second week of the month" window for all 12 monthly maintenance visits without deviation.

  • Factor II - Past Performance: Offerors must submit at least two (2) references for contracts performed within the last two (2) years that demonstrate successful maintenance, inspection, and certification of COMMERCIAL elevators of similar scope and complexity.

  • Factor III - Price: Pricing will be evaluated based on the Total Evaluated Price for completeness and realism. Labor rates must comply with the current SCA Wage Determination for Los Angeles.

Files

File Type Posted
SOW BLDG 20 ELEVATOR CONTRACT 2026-2027.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
Annual Inspection Maintenance of Manlifts New London, Connecticut 06320, United States · NAICS 811310 — Total Small Business
CAT 5 Elevator Inspection USP Atwater Atwater, California 95301, United States · NAICS 541350 United States Penitentiary Atwater Total Small Business
Articulating Boom Lift Rental Curtis Bay, Maryland 21226, United States · NAICS 532490 — Total Small Business
WTX Elevator Inspections and Load Testing Services Texas 79720, United States · NAICS 238290 Veterans Integrated Service Network 17 Service-Disabled Veteran-Owned Small Business
USCG STA coos BAY (47302-47242) FY27 DD repair Charleston, Oregon 97420, United States · NAICS 336611 — Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors