Elevator Inspection and Certification Services

Open Pre-Solicitation Posted

Solicitation number
140RR027Q0064
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
541350 Building Inspection Services

Notice details come from SAM.gov. Updated .

About this opportunity

The Bureau of Reclamation, Central California Area Office, is conducting market research through a Sources Sought Notice to identify firms capable of providing independent elevator inspection and certification services, with capability statements due December 3, 2026. No set-aside is used. The notice is not a solicitation and does not obligate the Government to award a contract, but market research results may inform competition, set-aside, and acquisition strategy decisions.

Place of performance is Folsom Dam and Folsom Powerplant in Folsom, California, and New Melones Powerplant in Jamestown, California, during Monday through Friday, 7:00 a.m. to 3:30 p.m. Pacific Time, excluding non-federal holidays. The requirement covers Qualified Elevator Inspector services for three electric passenger elevators: two Montgomery Elevators at Folsom (P-1 and P-2) and one Elevator Industries unit at New Melones (P-3), with capacities from 1,200 to 10,000 pounds.

Work must follow ASME A17.1, A17.2, A17.3, and QEI-1 standards and comply with Reclamation Safety and Health Standards, OSHA requirements, and FIST 1-1 Hazardous Energy Control Program standards. Scope includes one annual Category 1 inspection per elevator (unless superseded by a Category 5 inspection), one six-month inspection per elevator, witnessing of Category 1 and Category 5 testing performed by the existing maintenance contractor, Elevator Technology Inc., plus inspection reports, deficiency recommendations, and elevator certifications. The anticipated contract consists of a base year and four option years. The anticipated NAICS code is 541350, Building Inspection Services, with a size standard of $11.5 million. Interested firms must submit a capability statement addressing their ability to meet these requirements.

Notice text

Elevator Inspection and Certification Services

This is not a solicitation announcement. This is a Sources Sought Notice issued solely for market research and planning purposes. It does not constitute a Request for Quote (RFQ), and it does not obligate the Government to award a contract.
The Bureau of Reclamation, Interior Region 10, California Great Basin Region, Central California Area Office (CCAO), is seeking potential sources capable of providing independent elevator inspection and certification services for elevators located at Folsom Dam, Folsom Powerplant, and New Melones Powerplant in California. The Government is conducting market research to determine the availability of qualified firms and to assist in determining the appropriate acquisition strategy.
The requirement is for Qualified Elevator Inspector (QEI) services to perform periodic elevator inspections, witness required testing, provide inspection reports, identify deficiencies and recommendations, and provide elevator certifications in accordance with applicable ASME requirements, including ASME A17.1, A17.2, A17.3, and QEI-1 standards.

The anticipated contract will consist of a base year and four option years. Inspection services are anticipated to include:
- One annual Category 1 inspection for each of the three elevators (unless superseded by a Category 5 inspection).
- One periodic six-month inspection for each of the three elevators.
- Witnessing of Category 1 and Category 5 testing performed by the elevator maintenance contractor.
- Preparation and submission of inspection reports and certification documentation.

The anticipated NAICS code for this requirement is 541350 ¿ Building Inspection Services (Size Standard: $11.5 Million).

Competition, set-aside decisions, and acquisition strategy may be based on the results of this market research.

Interested firms should submit a capability statement addressing their ability to meet the requirements described above. Responses should include:
1. Company name, address, and SAM Unique Entity ID (UEI).
2. Business size and socioeconomic status (e.g., Small Business, HUBZone, SDVOSB, WOSB, 8(a)).
3. Relevant experience performing independent elevator inspection and certification services for commercial, industrial, utility, hydroelectric, or government facilities.
4. Confirmation that proposed inspectors possess current Qualified Elevator Inspector (QEI) certification and identification of the certifying organization.
5. Ability to perform inspections at Government facilities located in Folsom, California and Jamestown, California.
6. Any experience performing inspections in accordance with ASME A17.1, A17.2, A17.3, and QEI-1 standards.

Responses are due: Thursday, December 3, 2026 at 10:00am PT
Submit responses to: margaret_jones@ios.doi.gov

This notice is for market research purposes only and shall not be construed as a commitment by the Government to issue a solicitation or award a contract.

Files

File Type Posted
Performance_Work_Statement_1.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
H399--Vertical Lift Inspection Services VA Sierra Nevada Healthcare System Reno, Nevada, United States · NAICS 541350 Veterans Integrated Service Network 21 Service-Disabled Veteran-Owned Small Business
Professional Services for Construction Management Support NAICS 541330 — No set-aside
Friant Dam Janitorial Services NAICS 561720 — No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors