ZTL-CHILD signatures drawings Final.pdf
PDF 3 MB Posted
- Attached to
- ZTL Childcare Facility Paving Project
- Solicitation number
- 697DCK-26-R-00397
About this file
This file is a PDF portfolio cover page. The image displays an Adobe Acrobat logo on a red and white binder cover with two metal fasteners. The page contains a message instructing users to open the PDF portfolio in Acrobat X or Adobe Reader X, or later versions, for optimal viewing experience. A clickable button labeled "Get Adobe Reader Now!" is provided for users who need to download the required software. No contract-related information, procurement details, or substantive content is present on this page.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For the best experience, open this PDF portfolio in
Acrobat X or Adobe Reader X, or later.
Get Adobe Reader Now!
http://www.adobe.com/go/reader
12/04/2025
MGR: ENGINEERING - CENTER A
HAMPTON
ZTL-25014336-C001
DD
KS
CHILD
ZTL CCF REPLACE ASPHALT PARKING LOT
CONCRETE PLAN
z tl -2
-c
.d w g
MAINTENANCE SERVICE
PROGRAM ENGINEERING
SOUTHERN REGION ATLANTA, GA
C O
N S
T R
U
IO
ATLANTA CENTER
DRAWING PRODUCED ON ASO RO MICROSTATION SYSTEM
PROJECT ENGINEER
25014336
GA
SCALE: 1/16" = 1'-0"C001
STRUCTURE
DRAINAGE
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV DESCRIPTION JCN
DATE
REDLINE
APVD
SUBMITTED BY APPROVED BY
JCN
DRAWN
CHECKED
REV
ISSUED BY
H
G
F
E
D
B
A
8 1234567
DRAWING NO
DESIGNED
REVIEWED BY
/0
/2
:0
P
M lo tt e d b y
V
-C
-E
APPROVED
8 234567
PARKING
H/C
STOP
X X
IS
8' 0 10' 40'
SCALE: 1/16" = 1'-0"
20' 30'
MH
CENTER
CHILD CARE
NOTES
1. EROSION CONTROL PROTECTION DEVICES SHALL BE
INSTALLED AND MAINTAINED ON ALL DRAINAGE STRUCTURES
AND SURROUNDING SOIL AREAS.
2. REMOVE IDENTIFIED CONCRETE CURB AND GUTTER AND
REPLACE IN ACCORDANCE WITH SPECIFICATIONS.
3. MAINTAIN EXISTING GRADE OF THE SOIL AND RE-SOD UPON
COMPLETION OF CURB WORK TO MAINTAIN PROPER
DRAINAGE TO INSTALLED STRUCTURES.
ztl-25014336-c001
2026-04-07T17:05:11-0400
ANTONIO J JARENO
2026-04-07T16:37:41-0400
JAVIER ALEJANDRO COMAS RUIZ
ZTL-25014336-C002
NEW PARKING LOT
SCALE: 1/16" = 1'-0"C002
CONSTRUCTION
LIMIT OF
STORM DRAIN
ASPHALT PARKING LOT
REPLACED
REMOVED AND
AND GUTTER TO BE
CONCRETE CURB
ENCASEMENT
CONCRETE
INLET
PLAY-GROUND
C.O.
:1 lo tt e
X
XXX
PX X
ASPHALT
LEGEND
1. ONCE THE NEW ASPHALT IS PLACED IN THE PARKING LOT,
COMPACT THE ASPHALT SO THAT POSITIVE DRAINAGE CAN BE
ACHIEVED. VERIFY THE FINISH PAVEMENT SLOPES TO MATCH
THE CONCRETE ENCASEMENT AND NOT FLATTER THEN THE
MINIMUM SLOPE. INFORM COR IF THIS CANNOT BE ACHIEVED.
2. FINISH ASPHALT SURFACE MUST BE FLUSH WITHIN 1/8" WITH
EXISTING SURFACE FEATURES TO INCLUDE BUT NOT LIMITED TO
MANHOLES, STORM DRAINS, CONCRETE GUTTERS, PADS, VALVE
BOXES, UNLESS OTHERWISE NOTED.
ztl-25014336-c002
2026-04-07T17:05:24-0400
ANTONIO J JARENO
2026-04-07T16:37:46-0400
JAVIER ALEJANDRO COMAS RUIZ
ZTL-25014336-C003
STRIPPING PLAN
SCALE: 1/16" = 1'-0"C003
STRIPE (TYP.)
4" WIDE PAINTED
WALKWAY PAVEMENT MARKING
:3 lo tt e
XX
XXXXXX
9 PARKING SPACES
12 PARKING SPACES
1. THE PARKING LOT MUST BE STRIPED TO MATCH THE EXISTING
LAYOUT EXCEPT WHERE HANDICAP PARKING SPACE NEED TO
BE INSTALLED.IN ADDITION, ENSURE WALKWAY PAVEMENT
MARKING IS ADDED TO THE PARKING LOT.
2. ALL ARROWS AND STOP PAVEMENT MARKINGS MUST BE
REINSTALLED TO MATCH EXISTING AND PER SPECIFICATIONS.
3. CONTRACTOR SHALL ENSURE THAT ALL PARKING STALLS SHALL
NOT IMPEDE DRAINAGE STRUCTURES OR WALKWAY ACCESS.
ztl-25014336-c003
2026-04-07T17:05:35-0400
ANTONIO J JARENO
2026-04-07T16:37:51-0400
JAVIER ALEJANDRO COMAS RUIZ
ZTL-25014336-D004
DEMOLITION SITE PLAN
-d
STORM DRAIN
REPLACED
REMOVED AND
AND GUTTER TO BE
CONC CURB
CONC ENCASEMENT
C.O.
SCALE: 1/16" = 1'-0"D004
:3 lo tt e
-d
PX X
ASPHALT
LEGEND
MILL ASPHALT DOWN TO SUBGRADE.
REMOVE APPROXIMATELY 75 LF OF CONCRETE CURB AND GUTTER
TO BE FIELD VERIFIED AS SHOWN ON DRAWINGS OR AS MARKED BY
COR.
PROVIDE SEDIMENT CONTROL ON STORM DRAIN UNTIL
CONSTRUCTION IS COMPLETE.
MAINTAIN POSITIVE DRAINAGE OF WATER THROUGHOUT
CONSTRUCTION.
CONCRETE ENCASEMENT TO REMAIN AND UNDISTURBED BY
CONSTRUCTION ACTIVITIES. ANY DAMAGE TO ENCASEMENT SHALL
BE REPAIRED.
ztl-25014336-d004
2026-04-07T17:04:54-0400
ANTONIO J JARENO
2026-04-07T16:37:35-0400
JAVIER ALEJANDRO COMAS RUIZ
ZTL-25014336-G001
COVER SHEET AND VICINITY MAP
-g
VICINITY MAP
LOCATION
PROJECT
:4 lo tt e
T OF TRANSPO
T A
IC
OF
STATES
IT
P A
TM
EN
AVIA
LA
TRAT
SI
NI
NOT TO SCALE
LONGITUDE:
LATITUDE:
ZTL/CCF - HAMPTON, GEORGIA
CHILDCARE PARKING LOT REPAIR
ztl-25014336-g001
2026-04-07T16:53:39-0400
ANTONIO J JARENO
2026-04-07T16:36:40-0400
JAVIER ALEJANDRO COMAS RUIZ
ZTL-25014336-G002
GENERAL NOTES, DRAWING INDEX
AND CIVIL LEGEND
TITLE
SCALE: X" = 1'-0"SHT
X-NNN
ELEVATION REFERENCE LETTER
ELEVATION IS LOCATED
SHEET NUMBER WHERE
(PLAN, DETAIL / ELEVATION, SECTION)
REFERENCE NUMBER/LETTER
DETAIL, ELEVATION OR SECTION IS/ARE LOCATED
SHEET NUMBER(S) WHERE CALLOUT(S) TO PLAN,
SECTION REFERENCE LETTER
SECTION IS LOCATED
DETAIL REFERENCE NUMBER
DETAIL IS LOCATED
lo tt e
DRAWING NO.
SUBTITLE REFERENCE
ELEVATION CALLOUT REFERENCE
DETAIL CALLOUT REFERENCE
SECTION CALLOUT REFERENCE
ZTL-25014336-C003
ZTL-25014336-C002
ZTL-25014336-C001
ZTL-25014336-D004
ZTL-25014336-G003
ZTL-25014336-G002
ZTL-25014336-G001
EXISTING SITE PLAN AND GENERAL NOTES
GENERAL NOTES, DRAWING INDEX AND CIVIL LEGEND
COVER SHEET AND VICINITY MAP
WATER LINE
FIRE LINE
BUILDING
MANHOLE
GATE VALVE
CHECK VALVE
BLOW-OFF VALVE
AIR RELEASE VALVE
CULVERT
PROPERTY LINE
HAND HOLE
GAS LINE
FUEL OIL SUPPLY
FUEL OIL RETURN
CABLE TV LINE:
STEAM LINE
CONDENSATE RETURN
CLEANOUT
IRRIGATION MAIN
SPRINKLER HEADS
FIRE HYDRANT
POST INDICATOR VALVE
W W
F F
BO BO
AR AR
TV TV
TV TV
UG
G G
FOS FOS
FOR FOR
STM STM
CR CR
CO CO
1R 1R
X X X X X
CTS CTS
CTR CTRCOOLING TOWER WATER RETURN
COOLING TOWER WATER SUPPLY
OVERHEAD
UNDERGROUND
TELEPHONE LINE:
ELECTRIC POWER LINE:
CONDUIT
UTILITY POLE
STREET LIGHT
FLOOD LIGHTS
SWITCHING COMPARTMENT
TRANSFORMER
STORM DRAIN LINE
SD
SD
SEWER (SAN OR COMB)
EASEMENT LINE
CENTER LINE
FORCE MAIN FM FM
INDUSTRIAL WATER IW IW
SHRUBS
TREES:
CONTOUR LINE
PAVEMENT
GUTTER
27.5
27.51 G
27.52 C
27.54 P
TOP OF CURB
TOP OF WALL
DECIDUOUS (WITH DIAM)
27.51 G
27.52 C
27.54 P
27.5
CRUSHED ROCK
SS SS
FHFH
EXISTING NEW
X XX XX X X XX XX X
DIRECTION OF FLOW
UNDERGROUND ELECTRIC DUCT BANK
CBCB
CATCH BASIN
SPLICE BOX
24"
18"EVERGREEN (WITH DIAM)
SPOT ELEVATIONS - GRADE
SOIL BORING
FENCE:
CHAIN LINK
BARBED WIRE OR WELDED WIRE FABRIC
SECURITY
SILT FENCE
27.53 TW
27 27
27.53 TW
GRASSED AREA
ASPH PAVING
PCC CONCRETE
CHILLED WATER RETURN
CHILLED WATER SUPPLY
INDUSTRIAL COLD WATER
CWR
CWS
IW
EMBANKMENT
CWR
CWS
IW
ELECTRIC BUSS DUCT SUPPORT
XXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXX
ASPH PAVEMENT
FUEL OIL VENT FOV FOV
B-2
RECONSTRUCTED
TOP
CIVIL LEGEND
REV. DATE DESCRIPTION
DRAWING LIST
GENERAL NOTES
A. THE FACILITY WILL BE OCCUPIED BY CHILDREN DURING CONSTRUCTION.
COORDINATE THE WORK WITH COR TO AVOID DISRUPTING FACILITY
OPERATIONS. MAINTAIN MEANS OF EGRESS DURING DEMOLITION AND
CONSTRUCTION ACTIVITIES. IF AN EXIT IS TEMPORARILY PLACED OUT OF USE
DURING THE WORK, COORDINATE WITH COR RISK MITIGATION PLAN FOR
TEMPORARY EGRESS MEASURES. RISK MITIGATION MUST ADDRESS
ALTERNATIVE MEANS OF EGRESS FOR BUILDING OCCUPANTS, SIGNAGE,
TRAINING (IF REQUIRED BY COR), AND PHASING OF THE WORK SO ONLY ONE
EXIT IS OUT OF USE AT ANY ONE TIME. PROVIDE NECESSARY SIGNAGE
WARNING BUILDING OCCUPANTS OF THE CHANGE, AND THE DIRECTION TO
THE NEAREST EXIT.
B. DO NOT PERFORM UNSCHEDULED INTERRUPTIONS TO BUILDING UTILITIES
AND SERVICES. WORK REQUIRING PERMANENT, TEMPORARY OR PARTIAL
OUTAGES MUST BE SCHEDULED AND APPROVED IN WRITING BY COR AT
LEAST 10 WORKING DAYS IN ADVANCE OF PERFORMANCE OF WORK.
C. ONLY FAA PERSONNEL MAY OPERATE CIRCUIT BREAKERS. REQUEST
PERMISSION IN WRITING OF FAA IN ADVANCE FOR EACH CASE OF BREAKER
OPERATION. DO NOT OPEN (DE-ENERGIZE) OR CLOSE (ENERGIZE) ANY
CIRCUIT BREAKER OR PIPE VALVE. COORDINATE DE-ENERGIZING, AND
ENERGIZING, OF ANY PANEL BOARD FOR CIRCUIT BREAKER REPLACEMENT
WITH COR.
D. PERFORM WORK IN CONFINED SPACES OR AREAS IN ACCORDANCE WITH
OSHA REQUIREMENTS, 29 CFR 1910.146 AND 1926.21(B)(6).
E. DO NOT SCALE DRAWINGS.
F. A PHASING PLAN MUST BE SUBMITTED TO THE FAA COR/RE FOR APPROVAL
SHOWING HOW THE FACILITY WILL REMAIN FUNCTIONAL FOR VEHICLE
ACCESS, VEHICLE PARKING, PEDESTRIAN ACCESS, AND FIRE EGRESS PATHS
WHILE CONSTRUCTION OPERATIONS ARE ONGOING AND COMPLETED.
CONSTRUCTION DATES OF EACH PHASE MUST BE INCLUDED WITH PHASING
PLAN SUBMITTAL.
EXISTING NEW
ztl-25014336-g002
2026-04-07T17:00:50-0400
ANTONIO J JARENO
2026-04-07T16:37:19-0400
JAVIER ALEJANDRO COMAS RUIZ
ZTL-25014336-G003
EXISTING SITE PLAN
AND GENERAL NOTES
DRAINAGE
STORM
CURB
EXISTING
POLE
LIGHT
HYDRANT
EXISTING
:2 lo tt e
THE CONSTRUCTION.
CONTRACTOR MUST REPLACE ANYTHING DAMAGED DURING 6.
USE.
EROSION CONTROL MATERIALS CONTRACTOR PROPOSES TO
SUBMIT FOR APPROVAL OF TOPSOIL, SEED, SOD, AND 5.
IMMEDIATELY.
CONSTRUCTION, THE CONTRACTOR MUST NOTIFY FAA COR
IF EXCESS FUMES/DUST IS GENERATED DUE TO 4.
OR DISRUPT LOCAL FAA.
DUST CONTROL TO RESTRICT VISIBILITY OF PASSING TRAFFIC
MEANS TO REMOVE LOOSE DEBRIS OR DUST. DO NOT ALLOW
PROVIDE POWER BROOMS, VACUUM SWEEPERS, OR OTHER 3.
MUST BECOME THE PROPERTY OF THE CONTRACTOR.
ALL EXCESS MATERIAL FROM DEMOLITION AND EXCAVATION 2.
THE FACILITY GROUNDS.
COMPLETED BEFORE ANY DEMOLITION OR EXCAVATION ON
PRIOR TO THE START OF PROJECT, UTILITY MARKING MUST BE 1.
WORK AREAS
PROVIDE FIRE HYDRANT PROTECTION.
DAMAGE OR COORDINATE WITH THE LOCAL AUTHORITIES TO
CONTRACTOR MUST PROTECT FIRE HYDRANTS FROM 1.
EQUIPMENT PROTECTION
LOCATION WITH COR.
NOT BE USE TOILETS INSIDE FAA FACILITIES. COORDINATE
MUST BE PROVIDED BY CONTRACTOR. CONTRACTOR MUST
PORTABLE CHEMICAL TOILETS AND HAND WASH STATIONS 1.
CONSTRUCTION TOILET FACILITIES
CONTRACTOR MUST NOT USE FAA DUMPSTERS.3.
SITE.
MUST BE IMMEDIATELY CLEANED UP AND REMOVED FROM THE
OUT. LOOSE MATERIAL THAT IS DEPOSITED ON ANY SURFACE
REQUIREMENTS TO PREVENT LOOSE MATERIAL FROM FALLING
MUST BE COVERED PER ALL LOCAL AND STATE
TRUCKS HAULING MATERIALS TO AND FROM THE WORK SITE 2.
NO PAVEMENT DEBRIS SHALL BE STORED ON SITE.1.
CONSTRUCTION DEBRIS
APPROVED BY COR.
BE OFF-LIMITS FOR CONTRACTOR PARKING UNLESS
EXISTING PARKING SPACES IN CERTAIN AREAS AT ARTCC MAY
EQUIPMENT) MUST BE COORDINATED WITH LOCAL FAA.
CONTRACTORS PARKING (COMPANY TRUCKS AND 1.
CONTRACTOR PARKING
OF THE FAA CHILDCARE FACILITY AT ANY TIME.
CONTRACTOR MUST NOT BE ALLOWED ACCESS TO THE INSIDE 3.
CONSTRUCTION AREAS.
FENCING TO PROTECT, WARN AND DIRECT PERSONS NEAR
PROVIDE NECESSARY BARRICADES, LIGHTS, SIGNAGE, AND
CONSTRUCTION EMPLOYEES AND DELIVERIES ON SITE.
PROVIDE SIGNAGE TO INDICATE ACCESS ROUTE FOR 2.
PARTICULARLY IN CONJUNCTION WITH ONGOING PROJECTS.
COORDINATED WITH SITE PERSONNEL VIA COR;
AND EXTENT/SIZE OF CONSTRUCTION STAGING AREA MUST BE
CONSTRUCTION ACCESS, PARKING, CONSTRUCTION TRAILER 1.
CONSTRUCTION ACCESS
PAVEMENT MARKINGS
1. PRIOR TO ANY PAVEMENT DEMOLITION, MEASURE EXISTING
PARKING STALL, DRIVE AISLE AND PAINTED ISLAND DIMENSIONS IN
EACH PARKING AREA. THIS INFORMATION MUST BE USED TO
ESTABLISH NEW PAVEMENT MARKINGS.
PARKING LOT AND DRIVEWAY REPAIR
1. THE CONTRACTOR MUST FIELD VERIFY ALL ELEVATIONS AND
FLOW LINES BY A LICENSED SURVEYOR TO PROVIDE POSITIVE
FLOW TO INLETS. THIS PLAN MUST BE SUBMITTED FOR APPROVAL
BY FAA. PONDING OF WATER IS NOT ACCEPTABLE AND MUST BE
CORRECTED. COORDINATE CORRECTIVE MEASURES WITH THE
COR. THE CONTRACTOR MUST NOTIFY COR OF DIFFERING
CONDITIONS FOUND.
2. DISTURBED LAWNS AND LANDSCAPING MUST BE STABILIZED WITH
SOD. ALL OTHER ITEMS, INCLUDING BUT NOT LIMITED TO
SPRINKLER SYSTEM, SIDEWALKS AND CURBS, MUST BE RESTORED
TO EQUAL OR BETTER THEN ORIGINAL CONDITION BY
CONTRACTOR AT NO EXPENSE TO THE GOVERNMENT AND TO THE
SATISFACTION OF THE COR.
3. UNLESS OTHERWISE IDENTIFIED, REPLACEMENT PAVEMENT
GRADES MUST MATCH EXISTING GRADES.
4. AFTER MILLING OF THE PAVEMENT AND PRIOR TO ANY
RESURFACING THE EXISTING DRAINAGE STRUCTURES, VALVES,
ETC. MUST BE INSPECTED TO DETERMINE IF ANY ADJUSTMENT TO
THE STRUCTURES WILL BE REQUIRED TO MEET TOLERANCES
REQUIRED BY COR. ANY STRUCTURES THAT REQUIRE
ADJUSTMENTS MUST BE REPORTED TO THE COR IMMEDIATELY.
CONTRACTOR MUST ADJUST STRUCTURE PENDING COR EVAL.
5. FOR ALL INQUIRIES ON STRIPING FOR THE PARKING LOT
REFERENCE PLAN C103.
6. REMOVE ALL SIGNS AND POSTS AS DIRECTED BY THE COR.
CAUTION NOTES
1. UNDERGROUND UTILITIES EXIST WITHIN AND ADJACENT TO THE
LIMITS OF CONSTRUCTION. AN ATTEMPT WAS MADE TO LOCATE
THESE UTILITIES ON THE PLANS, HOWEVER, ALL EXISTING
UTILITIES MAY NOT BE SHOWN AND THE ACTUAL LOCATIONS OF
THE UTILITIES MAY VARY FROM THE LOCATIONS SHOWN. PRIOR TO
BEGINNING ANY TYPE OF EXCAVATION, THE CONTRACTOR MUST
PERFORM UTILITY LOCATE PER CONSTRUCTION SPECIFICATIONS.
2. DETAILED AS-BUILT DRAWINGS ARE TO BE MAINTAINED ON SITE
DURING CONSTRUCTION AND FINAL (DIGITAL) COPY MUST BE
SUBMITTED TO GOVERNMENT AT COMPLETION OF PROJECT.
3. NO EXCAVATION IS PERMITTED WITHOUT DIG PERMIT
ztl-25014336-g003
2026-04-07T17:04:42-0400
ANTONIO J JARENO
2026-04-07T16:37:25-0400
JAVIER ALEJANDRO COMAS RUIZ
File details come from the government source that posted it. Updated .