YNP North Entrance Station Full Drawing Set Volume 2 Building.pdf
PDF 15 MB Posted
- Attached to
- MT NPS Yell 11(2), North Entrance
- Solicitation number
- 69056719b000024
About this file
This document package includes construction drawings and specifications for renovations to the North Entrance Station at Yellowstone National Park. The project involves upgrading building systems and finishes at the main entrance facility and two kiosks. Key elements include replacing exterior cladding, windows, and roofing; upgrading interiors with new flooring, casework, and restrooms; and mechanical, electrical, and plumbing system replacements. The construction drawings provide architectural, structural, and MEP plans and details for the proposed renovations. Specifications and schedules call out materials and assemblies. The solicitation is for a small construction project to be awarded under simplified acquisition procedures.
View the file
Other files
Show all 43
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
YELLOWSTONE
NATIONAL
PARK
Y E L L O
W S T
O N E
R
IV
E R
212MONTANA
WYOMING
W Y
O M I N
G
I D
A H
O
To Cody, WY
Junction Madison
Junction Norris
Lake Hebgen
Lake Shoshone
Yellowstone
Lake
John D. Rockefeller, Jr.
Memorial Parkway
Mammoth
Junction Tower
Gardiner
3020100510
SCALE IN MILES
PROJECT MANAGER
C. KRATOVIL
NATIONAL
PARK
SERVICE
Department of the Interior
N for Vicinity Maps of Volume 1
See Sheets A.4 and A.5
C h e c k e d b y
D e s ig n e d b y
KEY MAP
NATIONAL PARK
YELLOWSTONE
W Y
O M I N
G
I D
A H
O
WYOMING
MONTANA
Lake
Hebgen
Lake
Shoshone Lake
Yellowstone
Y e llo w s to n e
R iv e r
R iv e r
S n a k e
Lake
Jackson
NATIONAL
PARK
YELLOWSTONE
MEMORIAL PARKWAY
JOHN D. ROCKEFELLER, Jr.
PARK
NAT'L
TETON
GRAND
Faithful
Old
Thumb
West
Lake
Hot Springs
Mammoth
Canyon
Jackson
U
S S u r ft
D c p w w o r k d y e ll o a .d g n
P
M
M a r c h
Q.1
STATE PROJECT
NUMBER
SHEET
U
S S u r ft
D c p w w o r k d y e ll o a .d g n
MT NPS YELLL 11(2)
M a r c h
C h e c k e d b y
D e s ig n e d b y
PLANS FOR PROPOSED PROJECT
Junction Canyon
MONTANA
PARK COUNTY
PROJECT AREA
NPS PMIS NO. 177136D
MT NPS YELL 11(2)
NORTH ENTRANCE
3 BUILDINGS
YELLOWSTONE NATIONAL PARK
NATIONAL PARK SERVICE
U. S. DEPARTMENT OF THE INTERIOR
Project Location
TYPE OF CONSTRUCTION:
DESIGN DESIGNATION:
Design vehicle e (max)
V
SADT (2033)
SADT (2013)
Volume 2 - Building Construction
Development and Sewer Installations, Drainage, Roadside
Volume 1 - Grading, Base, Paying, Waterline
SPECIFICATION:
VANCOUVER, WASHINGTON
WESTERN FEDERAL LANDS HIGHWAY DIVISION
FEDERAL HIGHWAY ADMINISTRATION
U.S. DEPARTMENT OF TRANSPORTATION
VOLUME 2 OF 2
BUIDLING DRAWINGS
WB-65
0.040
25 MPH
veh/day5980
2271 veh/day See Sheets Q.2 for Index to Sheets
Architectural Specifications, Section K
North Entrance Station Project Manual, on Federal Highway Projects, FP-14 and
Construction of Roads and Bridges
Standard Specifications for
NPS Drwg. No. 101/109186
NPS PMIS No. 177136D
' STATE PROJECT
SHEET
' NUMBER '
:' MT NPS YELL 11(2) Q.2
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
>- INDEX TO SHEETS INDEX TO SHEETS .0
"O
QI
VOLUME 2 OF 2 VOLUME 2 OF 2 (CONTINUED) QI
0\
0.1 TITLE SHEET S3.1 MAIN ENTRANCE BUILDING FOUNDATION PLAN
C
Q.2 INDEX TO SHEETS S3.2 MAIN ENTRANCE BUILDING FLOOR PLAN
C G100 CODE REVIEW S3.3 MAIN ENTRANCE BUILDING FRAMING PLAN
8101-103 CODE PLANS S3.4 MAIN ENTRANCE BUILDING ROOF FRAMING PLAN
A001 ABBREVIATIONS S3.5 KIOSK BUILDING PLANS
A002 WALL TYPES S4.0-4.3 BUILDING SECTIONS
"E' A100 ARCHITECTURAL SITE PLAN S5.0-5.4 STRUCTURAL DETAILS
A101 MAIN BUILDING FLOOR PLANS S6.0-6.2 MOMENT FRAME DETAILS
vi A102 KIOSK FLOOR PLANS F001 FIRE PROTIECTION LEGENDS & DETAILS
A103 ENLARGED PLANS F002 FIRE PROTIECTION SITIE PLAN
A104 PLAN DETAILS F003 FIRE PROTIECTION DETAILS
A105 MAIN BUILDING ROOF PLAN F004 FIRE RISER ELEVATION
>- A106 KIOSK ROOF PLANS F100 FIRE PROTIECTION PLAN .0
"O
A 107-112 ROOF DETAILS F200 FIRE PROTIECTION SECTIONS QI
A201-206 EXTIERIOR ELEVATIONS P001 PLUMBING SCHEDULES AND LEGENDS "iii
QI
0 A301-306 MAIN BUILDING SECTIONS P002 PLUMBING LEGEND AND DETAILS
A307 BUILDING SECTIONS P100 UNDERSLAB DWV PLAN
A308 KIOSK SECTIONS P101 MAIN FLOOR DWV PLAN
A309-312 MAIN BUILDING WALL SECTIONS P200 DOMESTIC WATIER PLANS
A313 KIOSK WALL SECTIONS M001 MECHANICAL LEGEND
A314-317 SAM DETAILS M002-004 MECHANICAL SCHEDULES
A318-320 SECTION DETAILS M100 HVAC MAIN BUILDING PLAN
A501 MAIN BUILDING FINISH PLANS M101 HVAC KIOSK PLAN
A502 KIOSK FINISH PLANS M300 MECHANICAL ROOM ISOMETRIC & DETAIL
A503 MAIN BUILDING FURNITURE PLAN M500 HEAT PUMP TIEMPERATURE CONTROL DIAGRAM
A504 KIOSK FURNITURE PLANS E001-003 ELECTRICAL LEGEND
A601 DOOR AND WINDOW SCHEDULES AND DETAILS E004 ELECTRICAL ONE-LINE & SECHEDULES
A602 DOOR AND WINDOW ELEVATIONS E005-008 ELECTRICAL SCHEDULES
A603-604 DOOR DETAILS E009 LIGHTNING PROTIECTION ELECTRICAL DETAILS
A605-609 WINDOW DETAILS E010 FIRE ALARM RISER ELECTRICAL DETAIL
2 A701-707 INTIERIOR ELEVATIONS E011-015 ELECTRICAL DETAILS
�I A801-802 CASEWORK DETAILS E100 ELECTRICAL SITIE
1/l
A901 MAIN BULDING REFLECTIED CEILING PLANS E200 ELECTRICAL LIGHTING PLAN !Il l
A902 KIOSK REFLECTIED CEILING PLANS E300 ELECTRICAL POWER PLAN
S1.0-1.2 STRUCTURAL NOTES E401 ELECTRICAL SPECIAL SYSTIEMS PLAN
ro, S1.3 SCHEDULES E500 ELECTRICAL LIGHTING PROTIECTION PLAN
S2.0-2.8 TYPICAL DETAILS ENV001 RADON PIPING PLAN
Q
S3.0 BUILDING OVERVIEW PLAN ENV002-004 RADON DETAILS
INDEX TO SHEETS
GOVERNING CODES: 2018 INTERNATIONAL BUILDING CODE WITH APPENDICES
2018 INTERNATIONAL ENERGY CONSERVATION CODE
2018 INTERNATIONAL FUEL GAS CODE
2018 INTERNATIONAL MECHANICAL CODE
2017 NATIONAL ELECTRICAL CODE
NFPA CODES
2018 INTERNATIONAL PLUMBING CODE
OCCUPANCY CLASSIFICATION: B
FIRE SPRINKLER SYSTEM: PROVIDED
CONSTRUCTION TYPE: VB
BASIC ALLOWABLE HEIGHT AND AREA FROM TABLE 504.3, 504.4, AND 506.2
ALLOWABLE HEIGHT: 3 STORIES, 60 FEET
ALLOWABLE AREA: 36,000 SF PER FLOOR (IF ONE STORY)
TOTAL GROSS BUILDING AREA = 1,223 SF
MAIN BUILDING = 1,033 SF
NORTH KIOSK = 95 SF
SOUTH KIOSK = 95 SF
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS FROM TABLE 601
FOR TYPE VB, ALL = 0 HOURS
FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION
DISTANCE FROM TABLE 602
IF FIRE SEPARATION DISTANCE ≥ 10 FEET, FOR VB CONSTRUCTION = 0 HOURS
MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF
OPENING PROTECTION FROM TABLE 705.8
FOR UNPROTECTED, SPRINKLERED (UP, S) OPENINGS:
IF FIRE SEPARATION DISTANCE IS GREATER THAN 30 FEET = NO LIMIT
INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY FROM TABLE 803.13
FOR GROUP B, SPRINKLERED:
EXIT ENCLOSURES AND EXIT PASSAGEWAYS = CLASS B
CORRIDORS = CLASS C
ROOMS AND ENCLOSED SPACES = CLASS C
OCCUPANT LOAD FACTOR FROM TABLE 1004.5
BUSINESS AREAS OCCUPANT LOAD FACTOR = 150 SF GROSS
MAIN BUILDING BUSINESS AREAS 807 SF / 150 SF = 6 OCCUPANTS
NORTH KIOSK BUSINESS AREAS 53 SF / 150 SF = 1 OCCUPANT
SOUTH KIOSK BUSINESS AREAS 53 SF / 150 SF = 1 OCCUPANT
TOTAL OCCUPANT LOAD = 11 OCCUPANTS
MINIMUM REQUIRED EGRESS WIDTH FROM SECTION 1005.3
OTHER EGRESS COMPONENTS = 11 x 0.2 = 2.2" REQUIRED, 72" INCHES PROVIDED
MAXIMUM COMMON PATH OF EGRESS TRAVEL FROM TABLE 1006.2.1 = SHALL NOT EXCEED 100 FEET
SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY FROM TABLE 1006.2.1
FOR B OCCUPANCY, MAXIMUM OCCUPANT LOAD = 49
CODE REVIEW INFORMATION
EXIT ACCESS TRAVEL DISTANCE FROM TABLE 1017.2
FOR B OCCUPANCY, WITH SPRINKLER SYSTEM = 300 FEET
CORRIDOR FIRE-RESISTANCE RATING FROM TABLE 1020.1
FOR B OCCUPANCY, WITH SPRINKLER SYSTEM, IF OCCUPIED LOAD SERVED BY CORRIDOR IS
GREATER THAN 30 = 0 HOUR RATING REQUIRED
DEAD END CORRIDORS, B OCCUPANCY, WITH SPRINKLER SYSTEM FROM SECTION 1020.4 = NO MORE
THAN 50 FEET
MINIMUM NUMBER OF PLUMBING FIXTURES FROM THE INTERNATIONAL PLUMBING CODE 2018
BASED ON BUSINESS OCCUPANCY = 8 TOTAL
SEPARATE FACILITES NOT REQUIRED FOR BUILDINGS WITH A TOTAL OCCUPANT LOAD OF 15 OR
FEWER PER SECTION 403.2
WATER CLOSETS: 1 PER 25 REQUIRED: 1 UNISEX
PROVIDED: 1 UNISEX
LAVATORIES: 1 PER 40 REQUIRED: 1 UNISEX
PROVIDED: 1 UNISEX
DRINKING FOUNTAIN: NOT REQUIRED FOR OCCUPANT LOAD OF 15 OR FEWER PER SECTION 410.2
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:0 :5
A
M G100
CODE REVIEW
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
BT A
ATE OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
S
M AON T AN
30'-0"
'-0
30'-0"
'-0
8888 SF
XXX/XX
EXIT PATH
SPACE AREA
OCCUPANCY TAG:
OCCUPANT LOAD FACTOR / OCCUPANCY TYPE
NUMBER OF OCCUPANTS
1 HOUR FIRE BARRIER - SEAL PERMIETER AND
PENETRATIONS PER DETAILS ON THIS SHEET
SEMI-RECESSED CABINET AND FIRE
EXTINGUISHER - SEE SPECIFICATIONS
SURFACE MOUNTED FIRE EXTINGUISHER - SEE
SPECIFICATIONS
M UL RATED FIRE DOOR AND FRAME WITH RATING AS
INDICATED
- SEE SHEET A601
NOTE: SEE ELECTRICAL FOR ILLUMINATED EXIT SIGNS.
CODE PLAN LEGEND
IMAGINARY LOT LINE FOR FIRE SEPARATION
DISTANCES
FEC
FE
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:0 :5
A
M G101
CODE PLANS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1" = 30'-0"G101
1 SITE CODE PLAN
TRUE NORTH
BT A
ATE OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
T
113112111110
48 SF
100/B
29 SF
100/B
29 SF
100/B
145 SF
100/B
73 SF
100/B
77 SF
100/B
89 SF
100/B
36 SF
100/B
20 SF
100/B
84 SF
100/B
38 SF
100/B
32'-0"
FEC
FEC
45M
8888 SF
XXX/XX
EXIT PATH
SPACE AREA
OCCUPANCY TAG:
OCCUPANT LOAD FACTOR / OCCUPANCY TYPE
NUMBER OF OCCUPANTS
1 HOUR FIRE BARRIER - SEAL PERMIETER AND
PENETRATIONS PER DETAILS ON THIS SHEET
SEMI-RECESSED CABINET AND FIRE
EXTINGUISHER - SEE SPECIFICATIONS
SURFACE MOUNTED FIRE EXTINGUISHER - SEE
SPECIFICATIONS
M UL RATED FIRE DOOR AND FRAME WITH RATING AS
INDICATED
- SEE SHEET A601
NOTE: SEE ELECTRICAL FOR ILLUMINATED EXIT SIGNS.
CODE PLAN LEGEND
IMAGINARY LOT LINE FOR FIRE SEPARATION
DISTANCES
FEC
FE
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:0 :5
A
M G102
CODE PLANS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
3/16" = 1'-0"G102
1 MAIN BUILDING CODE PLAN
ROOM CODE LEGEND
Number Name Area
101 VESTIBULE 44 SF
102 BREAK ROOM 84 SF
103 HALLWAY 55 SF
104 RESTROOM 49 SF
105 WORK ROOM 145 SF
106 VISITOR WINDOW 38 SF
107 WORK ROOM 77 SF
108 SUPERVISOR'S OFFICE 73 SF
109 EMPLOYEE WINDOW 29 SF
110 REMITTANCE ROOM 48 SF
111 IT CLOSET 29 SF
112 MECHANICAL ROOM 89 SF
113 EXTERIOR STORAGE 36 SF
114 WATER ENTRY 20 SF
121 NORTH KIOSK 53 SF
122 SOUTH KIOSK 53 SF
NORTH REF
BT A
AT
E OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
53 SF
100/B
53 SF
100/B
9'-6"
9'-6"
FE
FE
8888 SF
XXX/XX
EXIT PATH
SPACE AREA
OCCUPANCY TAG:
OCCUPANT LOAD FACTOR / OCCUPANCY TYPE
NUMBER OF OCCUPANTS
1 HOUR FIRE BARRIER - SEAL PERMIETER AND
PENETRATIONS PER DETAILS ON THIS SHEET
SEMI-RECESSED CABINET AND FIRE
EXTINGUISHER - SEE SPECIFICATIONS
SURFACE MOUNTED FIRE EXTINGUISHER - SEE
SPECIFICATIONS
M UL RATED FIRE DOOR AND FRAME WITH RATING AS
INDICATED
- SEE SHEET A601
NOTE: SEE ELECTRICAL FOR ILLUMINATED EXIT SIGNS.
CODE PLAN LEGEND
IMAGINARY LOT LINE FOR FIRE SEPARATION
DISTANCES
FEC
FE
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:0 :5
A
M G103
CODE PLANS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
3/16" = 1'-0"G103
1 KIOSKS CODE PLAN
NORTH REF
ROOM CODE LEGEND
Number Name Area
101 VESTIBULE 44 SF
102 BREAK ROOM 84 SF
103 HALLWAY 55 SF
104 RESTROOM 49 SF
105 WORK ROOM 145 SF
106 VISITOR WINDOW 38 SF
107 WORK ROOM 77 SF
108 SUPERVISOR'S OFFICE 73 SF
109 EMPLOYEE WINDOW 29 SF
110 REMITTANCE ROOM 48 SF
111 IT CLOSET 29 SF
112 MECHANICAL ROOM 89 SF
113 EXTERIOR STORAGE 36 SF
114 WATER ENTRY 20 SF
121 NORTH KIOSK 53 SF
122 SOUTH KIOSK 53 SF
BT A
AT
E OF MONTAN
L
IC
E
N
S ED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
B ANCHOR BOLT
AC ACOUSTICAL
ACCESS ACCESSIBLE
ACT ACOUSTICAL CEILING TILE
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AGG AGGREGATE
ALT ALTERNATE
ANOD ANODIZED
ARCH ARCHITECT (URAL)
BD BOARD
BIB BLOWN-IN BATT
BLDG BUILDING
BLKG BLOCKING
BM BENCHMARK
BOS BOTTOM OF STRUCTURE
BRG BEARING
C CARPET
CAB CABINET
CER CERAMIC
CG CORNER GUARD
CJT CONTROL JOINT
CLG CEILING
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS, CONTINUE
CONTR COTNRACT (OR)
CSVB COVED SHEET VINYL BASE
DEMO DEMOLISH, DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DL DEAD LOAD
DTL DETAIL
DWG DRAWING
EB EXPANSION BOLT
ELEC ELECTRIC (AL)
ELEV ELEVATION
EP EPOXY PAINT
EQ EQUAL
EST ESTIMATE
EXIST EXISTING
EXP EXPOSED
EJ EXPANSION JOINT
EXT EXTERIOR
FA FIRE ALARM
FBO FURNISHED BY OTHERS
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FACTORY FINISH
FIN FINISH (ED)
FLR FLOOR (ING)
FND FOUNDATION
FO FACE OF
FOC FACE OF CONCRETE
ABBREVIATIONS
FOS FACE OF STUD
FP FIREPROOF
FR FIRE RATED
FT FIRE TREATED
FRP FIBERGLASS REINFORCED PANEL
FTG FOOTING
FUR FURRED (ING)
GA GAGE, GAUGE
GC GENERAL CONTRACTOR
GYP GYPSUM
HDR HEADER
HC HOLLOW CORE
HM HOLLOW METAL
HOR HORIZONTAL
HT HEIGHT
HTG HEATING
HVAC HEATING/VENTILATING/AIR CONDITIONING
IFRM INTUMESCENT FIRE-RESISTIVE MATERIAL
INCL INCLUDE (D), (ING)
ID INSIDE DIAMETER
INSUL INSULATE (D), (ION)
INT INTERIOR
JT JOINT
LAV LAVATORY
LL LIVE LOAD
MATL MATERIAL
MAX MAXIMUM
MBR MEMBER
MC MECHANICAL CONTRACTOR
MECH MECHANICAL (DWGS, SPECS)
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MTD MOUNT (ED), (ING)
MTL METAL
NIC NOT IN CONTRACT
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
OC ON CENTER (S)
OPNG OPENING
OPP OPPOSITE
OD OUTSIDE DIAMETER
O/ OVER
OFCI OWNER FURNISHED, CONTRACTOR
INSTALLED
OFOI OWNER FURNISHED, OWNER INSTALLED
P PAINT (ED)
PEFS PREFORMED EXPANDING FOAM SEALANT
PCF POUNDS PER CUBIC FOOT
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLF POUNDS PER LINEAL FOOT
PLY PLYWOOD
PREFIN PRE-FINISHED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PVC POLYVINYL CHLORIDE
Q TILE QUARRY TILE
QTY QUANTITY
RB RUBBER BASE
REF REFERENCE
REINF REINFORCE (D), (ING)
REQD REQUIRED
REV REVISION (S), REVISED
RO ROUGH OPENING
SAM SELF ADHERED MEMBRANE
SC SOLID CORE
SCH SCHEDULE
SCW SOLID CORE WOOD
SFRM SPRAY-FOAMED FIRE RESISTIVE MATERIAL
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION (S)
SQ SQUARE
STD STANDARD
STOR STORAGE
STRUCT STRUCTURAL (DWGS, SPECS)
SYS SYSTEM
SV SHEET VINYL
TD TRENCH DRAIN
TEL TELEPHONE
T&G TONGUE AND GROOVE
TOW TOP OF WALL
TYP TYPICAL
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VER VERIFY
VERT VERTICAL
VIF VERIFY IN FIELD
WC WATER CLOSET
WD WOOD
WB WOOD BASE
WH WATER HEATER
W/ WITH
W/O WITHOUT
WWG WELDED WIRE FABRIC
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :5
A
M A001
ABBREVIATIONS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
M AONT AN
B EXTERIOR WALL
NATURAL STONE VENEER
1" AIR SPACE - FILL WITH PEA GRAVEL
2 LAYERS 1 1/2" FIBERGLASS-FACED
POLYISOCYANURATE. STAGGER AND TAPE
OUTERLAYER JOINTS.
MASONRY TIES AT 16" O.C. E.W.
WALL SELF ADHERING MEMBRANE (SAM)
VAPOR BARRIER
1/2" PLYWD SHEATHING
2x6 STUDS AT 16" O.C. - SEE STRUCT
5/8" TYPE 'X' GYP BOARD
1'-2 1/4"
C EXTERIOR WALL
FIBER CEMENT SIDING
AIR SPACE
2 LAYERS 1 1/2" FIBERGLASS-FACED
POLYISOCYANURATE. STAGGER AND TAPE
OUTERLAYER JOINTS.
WALL SELF ADHERING MEMBRANE (SAM)
VAPOR BARRIER
1/2" PLYWD SHEATHING
2x6 STUDS AT 16" O.C. - SEE STRUCT
5/8" TYPE 'X' GYP BOARD
11"
D INTERIOR WALL
5/8" TYPE 'X' GYP BOARD
2x6 STDS AT 16" O.C.
SOUND BATT INSULATION
E INTERIOR WALL
5/8" TYPE 'X' GYP BOARD
2x4 STDS AT 16" O.C.
SOUND BATT INSULATION
6 3/4"
4 3/4"
A FOUNDATION WALL
2" EXTRUDED POLYSTYRENE
FOUNDATION WALL - SEE STRUCT.
1x4 WD FURRING STRIPS AT 16" O.C. -
MECHANICALLY FASTENED AT 16" O.C. TO STUDS
5/8" TYPE 'X' GYP BOARD
5/8" TYPE 'X' GYP BOARD
CMU - SEE STRUCT.
WALL TYPE LEGEND
GROUT COLLAR JOINT FULL
F INTERIOR WALL
5/8" TYPE 'X' GYP BOARD
2x8 STDS AT 16" O.C.
SOUND BATT INSULATION
8 1/2"
5/8" TYPE 'X' GYP BOARD
NOTE:
SET ALL STONE AND PRECAST CONCRETE ELEMENTS IN FULL BED OF
MORTAR WITH FULL HEAD AND SIDE JOINTS FROM FRONT FACE TO BACK
FACE OF STONE OR PRECAST CONCRETE AS SPECIFIED. AIR GAPS IN
MORTAR, FOREIGN MATERIALS, AND SHIMMING SHALL NOT BE SUBSTITUTED
FOR MORTAR.
SCALE: 1" = 1'-0"
GENERAL WALL TYPE NOTES:
A. SEE INTERIOR ELEVATIONS (SHEET A701) AND FINISH SCHEDULE (SHEET
A501) FOR WALL FINISHES.
B. PROVIDE BLOCKING AS REQUIRED TO SECURE WALL HUNG COMPONENTS.
C. EXTEND ALL COMPONENTS TO UNDERSIDE OF DECK, UNLESS NOTED
OTHERWISE.
D. ALL WALL TYPES IN LEGEND SHOWN IN PLAN VIEW.
KEYNOTES:
1. PLYWD ON STORAGE SIDE OF WALL TO 8'-0" AFF.
WALL TYPE LEGEND
FLOOR ASSEMBLY
WOOD FLOOR JOISTS - SEE
STRUCTURAL
PLYWOOD OR OSB FLOOR
SHEATHING SUB-FLOOR - SEE
STRUCTURAL
FLOOR FINISH - SEE FINISH
PLANS AND SPECIFIATIONS
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :5
A
M A002
WALL TYPES
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
BT A
ATE OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
M AONTAN
DOWNLIT
FLAGPOLE
MECHANICAL AIR
INTAKE - SEE VOL 1
FOR LOCATION. SEE
MECH
N E
W W
A T
E R
M A
IN
NEW TRANSFORMER -
SEE ELEC
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :5
A
M A100
ARCHITECTURAL SITE PLAN
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1" = 30'-0"A100
1 ARCHITECTURAL SITE PLAN
TRUE NORTH
SITE SHOWN FOR REFERENCE ONLY
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
WALL TYPE (SEE SHEET A002)
WALL TYPE NOTE
ROOM NUMBER
WINDOW TYPE (SEE SHEET A601 & A602)
PLAN NOTE
DETAIL OR SECTION NUMBER
SHEET WHERE DRAWN
DOOR NUMBER (SEE SHEET A601 & A602)
DIMENSION TO FACE OF STUD
DIMENSION TO GRID LINE
-1
A101
SIM
X
XX
X
PLAN LEGEND
1. CRAWLSPACE ACCESS - SEE A320.
2. ENTRY GRATE - SEE STRUCT.
3. MECH. EQUIPMENT - SEE MECH.
4. WATER HEATER - SEE PLUMBING.
5. CONCRETE MECHANICAL UNIT PAD.
6. TWO BURNER ELECTRIC COOKTOP.
# PLAN KEYNOTES
A. SEE SHEET G100 FOR BUILDING CODE INFORMATION AND LOCATIONS OF
FIRE RATED CONSTRUCTION.
B. SEE SHEET A001 FOR ABBREVIATIONS.
C. SEE SHEET A002 FOR WALL TYPES.
D. SEE SHEET A002 FOR FLOOR ASSEMBLIES.
E. FOR RODENT AND INSECT INFESTATION CONTROL THE CONTRACTOR SHALL
BE RESPONSIBLE FOR SEALING ALL MATCH-LINE CONSTRUCTION OPENINGS
THROUGHOUT THE PERIMETER OF THE BUILDING STRUCTURE, INCLUDING
AT THE ROOF AND FOUNDATION LEVEL.
F. FOR ALL WALL PENETRATIONS THROUGH STONEWORK - SEE 2/A320.
GENERAL PLAN NOTES
101-2 101-1
112-11
-1
-1
-1
-1
-1
-1
113112
104 102
113-1
A304
A301
A303
A305
1'-4" 4"
6'-0"
4" 6"
3'-4" 5'-0"
1'-8" 10"
4'-0" 15'-8" 6'-0"
8'-4" 11'-0" 25'-8"
4'-4" 3'-4"
8"
3'-8" 5'-0" 2'-4" 2'-4"
2'-0"
5'-0" 6'-0" 10'-4"
8'-6" 10'-0" 26'-6"
45'-0"
A307
16'-6 1/4" 7'-6 3/4" 12'-2" 6'-11 1/4"
/8
/8
/2
7'-0 5/8" 4'-6" 9'-6" 5'-5 3/8"
/2
/4
A306
EE
C C C
D
E
E
D
EE
C CC
E
C
E
F
E
E
C B
B
EE
B
B
5 1/4"
A302
A104
A104
A307
C
E
F F
A C
F
D
F B
CC
A104
ABOVE
G
A103
SCALE: 1" = 1'-0"
GENERAL WALL TYPE NOTES:
A. SEE INTERIOR ELEVATIONS (SHEET A701) AND FINISH SCHEDULE (SHEET
A501) FOR WALL FINISHES.
B. PROVIDE BLOCKING AS REQUIRED TO SECURE WALL HUNG COMPONENTS.
C. EXTEND ALL COMPONENTS TO UNDERSIDE OF DECK, UNLESS NOTED
OTHERWISE.
D. ALL WALL TYPES IN LEGEND SHOWN IN PLAN VIEW.
KEYNOTES:
1. PLYWD ON STORAGE SIDE OF WALL TO 8'-0" AFF.
WALL TYPE LEGEND
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :5
A
M A101
MAIN BUILDING FLOOR PLAN
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/8" = 1'-0"A101
1 MAIN BUILDING FIRST FLOOR PLAN
ROOM LEGEND - MAIN
Number Name
108 SUPERVISOR'S OFFICE
109 EMPLOYEE WINDOW
110 REMITTANCE ROOM
111 IT CLOSET
112 MECHANICAL ROOM
113 EXTERIOR STORAGE
114 WATER ENTRY
ROOM LEGEND - MAIN
Number Name
101 VESTIBULE
102 BREAK ROOM
103 HALLWAY
104 RESTROOM
105 WORK ROOM
106 VISITOR WINDOW
107 WORK ROOM
NORTH REF
ARCH 100'-0" ELEVATION = 5344.61' = T.O. FINISH FLOOR ELEVATION
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A308
A308
121-1
13'-0"
3'-8" 5'-0" 4'-4"
10'-8 3/4"
/4
D
F
D
3'-8" 5'-0" 4'-4"
122-2
A308
A308
13'-0"
3'-8" 5'-0" 4'-4"
10'-8 3/4"
/4
D
F
D
3'-8" 5'-0" 4'-4"
1. CRAWLSPACE ACCESS - SEE A320.
2. ENTRY GRATE - SEE STRUCT.
3. MECH. EQUIPMENT - SEE MECH.
4. WATER HEATER - SEE PLUMBING.
5. CONCRETE MECHANICAL UNIT PAD.
6. TWO BURNER ELECTRIC COOKTOP.
# PLAN KEYNOTES
A. SEE SHEET G100 FOR BUILDING CODE INFORMATION AND LOCATIONS OF
FIRE RATED CONSTRUCTION.
B. SEE SHEET A001 FOR ABBREVIATIONS.
C. SEE SHEET A002 FOR WALL TYPES.
D. SEE SHEET A002 FOR FLOOR ASSEMBLIES.
E. FOR RODENT AND INSECT INFESTATION CONTROL THE CONTRACTOR SHALL
BE RESPONSIBLE FOR SEALING ALL MATCH-LINE CONSTRUCTION OPENINGS
THROUGHOUT THE PERIMETER OF THE BUILDING STRUCTURE, INCLUDING
AT THE ROOF AND FOUNDATION LEVEL.
F. FOR ALL WALL PENETRATIONS THROUGH STONEWORK - SEE 2/A320.
GENERAL PLAN NOTES
WALL TYPE (SEE SHEET A002)
WALL TYPE NOTE
ROOM NUMBER
WINDOW TYPE (SEE SHEET A601 & A602)
PLAN NOTE
DETAIL OR SECTION NUMBER
SHEET WHERE DRAWN
DOOR NUMBER (SEE SHEET A601 & A602)
DIMENSION TO FACE OF STUD
DIMENSION TO GRID LINE
-1
A101
SIM
X
XX
X
PLAN LEGEND
SCALE: 1" = 1'-0"
GENERAL WALL TYPE NOTES:
A. SEE INTERIOR ELEVATIONS (SHEET A701) AND FINISH SCHEDULE (SHEET
A501) FOR WALL FINISHES.
B. PROVIDE BLOCKING AS REQUIRED TO SECURE WALL HUNG COMPONENTS.
C. EXTEND ALL COMPONENTS TO UNDERSIDE OF DECK, UNLESS NOTED
OTHERWISE.
D. ALL WALL TYPES IN LEGEND SHOWN IN PLAN VIEW.
KEYNOTES:
1. PLYWD ON STORAGE SIDE OF WALL TO 8'-0" AFF.
WALL TYPE LEGEND
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :5
A
M A102
KIOSK FLOOR PLANS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/4" = 1'-0"A102
1 NORTH KIOSK FIRST FLOOR PLAN
1/4" = 1'-0"A102
2 SOUTH KIOSK FIRST FLOOR PLAN
NORTH REF
NORTH REF
ROOM LEGEND - KIOSKS
Number Name
121 NORTH KIOSK
122 SOUTH KIOSK
ARCH 100'-0" ELEVATION = 5344.50' = T.O. FINISH FLOOR
ARCH 100'-0" ELEVATION = 5344.08' = T.O. FINISH FLOOR BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A301
A302
A104
A104
" 2
"4
A
A
A
A
A
A
C
B
B
B
B
ABOVE
ABOVE
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :5
A
M A103
ENLARGED PLANS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/4" = 1'-0"A103
1 WEST EXTERIOR WALL ENLARGED PLAN
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
FIBER CEMENT
LAPPED SIDING
PRECAST CONCRETE
WATER TABLE BELOW
SEALANT & BACKER
ROD - EITHER SIDE OF
TRIM
2x4 FIBER CEMENT
TRIM BOARDS
STONE VENEER
FIBER CEMENT PANEL
SIDING
PRECAST CONCRETE
WATER TABLE BELOW
SEALANT & BACKER
ROD
1x3 FIBER CEMENT
TRIM BOARDS
STONE VENEER -
WRAP INTO DOOR
OPENING
D
C
B
SPRAY FOAM
MITER OUTSIDE CORNERS OF
FIBER CEMENT LAP SIDING
C
C
3/4" PLYWD BLOCKING AT
CORNERS
FIBER CEMENT PANEL
SIDING
FIBER CEMENT
LAPPED SIDING
1x3 FIBER CEMENT
TRIM BOARDS
D
C
C
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :5
A
M A104
PLAN DETAILS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1 1/2" = 1'-0"A104
2 STONE TO SIDING TRANSITION
1 1/2" = 1'-0"A104
1 STONE TO SIDING AT CORNER
3" = 1'-0"A104
3 LAP SIDING OUTSIDE CORNERS
1 1/2" = 1'-0"A104
4 SIDING INSIDE CORNERS
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A304
A301
A303
A305
_______________ 2
A307
_______________1
A306
A302
6" / 12"
6" / 12"
8 7/8"
6'-3" 2'-3" 9'-5 1/2"
2'-10 3/4"
23'-7 1/4"
8 7/8"
/2
6'-3 7/8"
2'-0 1/8"
10'-5 1/2"
2'-0 1/8"
/2
/2
RIDGE
R
ID
G E
R
ID
G E
/8
A307
6" / 12"
6" / 12"
45'-11 1/4"
A112
A112
A112
VTR
VTR
VTR
RIDGE
VTR
E#
M#
RV ROUND VENT THRU ROOF
PLUMBING VENT THRU ROOF - PAINT TO MATCH ROOF
MATERIAL
DIRECTION OF SLOPED ROOF DECK / STRUCTURE
ROOF SLOPE RIDGE LINE
ROOF SLOPE VALLEY LINE
FACE OF WALL BELOW
ROOF EDGE
SYNTHETIC ROOF SHAKES
ROOF PLAN NOTE
ROOF PLAN ELECTRICAL NOTE
ROOF PLAN MECHANICAL NOTE
ROOF SYMBOL LEGEND
STRUCTURE BELOW -
SEE STRUCT.
MECHANICALLY FASTENED
VENTING COMPOSITE INSULATION
BOARD
ROOF SAM - ICE DAM PROTECTION
SYNTHETIC ROOF SHAKES
PLYWD SHEATHING - SEE STRUCT.
DOUBLE SHAKES EVERY 5
COURSES
ROOF SAM - VAPOR BARRIER
3" MECHANICALLY ATTACHED FLAT
STOCK INSULATION
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :5
A
M A105
MAIN BUILDING ROOF PLAN
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/8" = 1'-0"A105
1 MAIN BUILDING ROOF PLAN
NORTH REF
1 1/2" = 1'-0"A105
2 SHAKE ROOF ASSEMBLY
BT A
ATE OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A308
A308
/8
/2
/8
1'-2 1/8"
12'-5 1/2"
1'-2 1/8"
14'-9 3/4"
6" / 12"6" / 12"
A111
A111
R
ID
G E
/4
A112
A308
A308
6" / 12"6" / 12"5
/8
/2
/8
1'-2 1/8"
12'-5 1/2"
1'-2 1/8"
14'-9 3/4"
A111
A111
R
ID
G E
/4
A112
RIDGE
VTR
E#
M#
RV ROUND VENT THRU ROOF
PLUMBING VENT THRU ROOF - PAINT TO MATCH ROOF
MATERIAL
DIRECTION OF SLOPED ROOF DECK / STRUCTURE
ROOF SLOPE RIDGE LINE
ROOF SLOPE VALLEY LINE
FACE OF WALL BELOW
ROOF EDGE
SYNTHETIC ROOF SHAKES
ROOF PLAN NOTE
ROOF PLAN ELECTRICAL NOTE
ROOF PLAN MECHANICAL NOTE
ROOF SYMBOL LEGEND
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :5
A
M A106
KIOSK ROOF PLANS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/4" = 1'-0"A106
1 NORTH KIOSK ROOF PLAN
1/4" = 1'-0"A106
2 SOUTH KIOSK ROOF PLAN
NORTH REF
NORTH REF
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
3/4" TONGUE AND
GROOVE WOOD
CEILING ON 5/8"
GYP BD
WD TOP PLATE -
SEE STRUCT.
RAFTERS - SEE
STRUCT.
C
2x6 FIBER
CEMENT FASCIA
TRIM BOARD
SEALANT
FIBER CEMENT
LAP SIDING
S.A.M.
A108
EXPOSED RAFTER
TAILS - PAINT - SEE
STRUCT.
A108
SEALANT
SYNTHETIC ROOF SHAKES
CUT BACK SHINGLES 2"
FROM CENTER OF
VALLEY
3" WIDE APPLICATION OF
ASPHALT ROOF CEMENT
ROOF SAM VAPOR BARRIER
DOWN VALLEY - 2 ROLLS
WIDE, OVERLAP 6" IN THE
VALLEY
ROOF SAM - ICE DAM
PROTECTION
NOTE(S):
1. EXTEND A FULL SHINGLE AT LEAST 12" FROM CENTER OF VALLEY.
2. NO NAILS ARE TO BE USED WITHIN 6" OF THE CENTER OF VALLEY.
3. TWO NAILS ARE TO BE USED AT THE END OF EACH SHINGLE
EXTENDING UNDER CUT SHINGLES.
4. TRIM UPPER CORNER AND APPLY BEAD OF ROOF CEMENT AT THE
EDGE OF EACH SHINGLE.
5. INTER-WEAVE UNDERLAYMENT IN VALLEY TO SHED WATER.
VALLEY FLASHING
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :5
A
M A107
ROOF DETAILS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1 1/2" = 1'-0"A107
1 ROOF EAVE AT MAIN BUILDING
3" = 1'-0"A107
2 VALLEY DETAIL
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
SYNTHETIC ROOF
SHAKES
1" AIR SPACE
2X BLOCKING AT
END OF VENTING
COMPOSITE
INSULATION BOARD
TERMINATE ROOF
SAM VAPOR
BARRIER AT
BLOCKING
RUN WALL SAM
ONTO UNDERSIDE
OF ROOF
SHEATHING
METAL SOFFIT
PANELS ON
UNDERSIDE OF
ROOF SHEATHING
SPRAY FOAM
INSULATION
2x6 FIBER CEMENT
FASCIA TRIM
BOARDS
SEALANT
EXPOSED
RAFTER TAILS -
PAINT - SEE
STRUCTURE
/2
ROOF SAM - ICE
DAM PROTECTION
VENTING
COMPOSITE
INSULATION
BOARD
PERFORATED
METAL SOFFIT
PANEL
PREFINISHED
METAL FLASHING
ROOF SAM - ICE
DAM PROTECTION
SYNTHETIC ROOF
SHAKES
2X BLOCKING
EXPOSED
STRUCTURAL
RAFTER TAIL
METAL FASCIA
PANEL
ROOF SHEATHING
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :5
A
M A108
ROOF DETAILS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
3" = 1'-0"A108
2 WALL TO ROOF AT EAVE
3" = 1'-0"A108
1 ROOF EAVE EDGE
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
3/4" TONGUE
AND GROOVE
WOOD CEILING
WD TOP PLATE -
SEE STRUCT.
RAFTERS - SEE
STRUCT.
2x6 FIBER CEMENT
FASCIA TRIM BOARD
SEALANT
FIBER CEMENT
LAP SIDING
WALL SAM
VAPOR
BARRIER
A109
5/8" TYPE 'X'
GYP BD
SEALANT
PREFINISHED
METAL
FLASHING
ROOF SAM -
ICE DAM
PROTECTION
SYNTHETIC
ROOF SHAKES
2X BLOCKING
TERMINATE ROOF
SAM VAPOR
BARRIER UNDER
BLOCKING
RAFTER -
PAINT - SEE
SPRAY FOAM
INSULATION
WRAP WALL
SAM ONTO
UNDERSIDE
OF ROOF
SHEATHING
2x6 FIBER CEMENT
FASCIA TRIM BOARD
SEALANT
METAL SOFFIT
PANELS
/2
METAL FASCIA
PANEL
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :5
A
M A109
ROOF DETAILS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1 1/2" = 1'-0"A109
1 ROOF RAKE AT MAIN BUILDING
3" = 1'-0"A109
2 ROOF RAKE EDGE
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
C
WD TOP PLATE - SEE
STRUCT.
RAFTERS - SEE
STRUCT.
SPRAY FOAM
INSULATION
2x6 FIBER CEMENT TRIM
BOARD
SEALANT
FIBER CEMENT PANEL
SIDING
WALL SAM VAPOR
BARRIER
5/8" TYPE 'X' GYP BD
A108
SIM
A108
SIM
3/4" TONGUE & GROOVE
WD CEILING
SEALANT
LEAVE 1/4" GAP AT TOP
FOR PIPE MOVEMENT1
LAP FLASHING 1" MIN.
INTO PIPE
PRE-FIN METAL
FLASHING
SYNTHETIC
ROOF
SHAKE
ROOF CEMENT
UNDER
PIPE - SEE
PLUMBING
PIPE - SEE
MECHANICAL,
PLUMBING
SPRAY FOAM
AROUND PIPE
SAM PATCH
AROUND PIPE
ROOF SAM ICE
DAM
PROTECTION
M
IN
SAM PATCH -
WRAP UP AND
AROUND PIPE
ROOF SAM
VAPOR
BARRIER
AROUND PIPE
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :5
A
M A110
ROOF DETAILS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1 1/2" = 1'-0"A110
1 ROOF EAVE AT TRANSACTION WINDOW
3" = 1'-0"A110
2 PIPE/VENT PENETRATION AT SHAKES
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
5/8" TYPE 'X' GYP BD
WD TOP PLATE -
SEE STRUCT.
RAFTERS - SEE
STRUCT.
FIBER CEMENT PANEL
SIDING
WALL SAM VAPOR
BARRIER
A108
SIM
A108
SIM
3/4" TONGUE &
GROOVE WD CEILING
SEALANT
3/4" TONGUE &
GROOVE WD CEILING
WD TOP PLATE -
SEE STRUCT.
RAFTERS - SEE
STRUCT.
2x6 FIBER CEMENT
TRIM BOARD
FIBER CEMENT PANEL
SIDING
WALL SAM VAPOR
BARRIER
A109
SIM
5/8" TYPE 'X' GYP BD
SEALANT
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A111
ROOF DETAILS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1 1/2" = 1'-0"A111
2 ROOF EAVE AT KIOSK
1 1/2" = 1'-0"A111
1 ROOF RAKE AT KIOSK
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
3"
ROOF STRUCTURE
BELOW - SEE STRUCT.
PLYWD SHEATHING -
SEE STRUCT.
ROOF SAM VAPOR
BARRIER
3" FLAT STOCK
INSULATION
COMPOSITE INSULATION
BOARD
ROOF SAM - ICE DAM
PROTECTION
SYNTHETIC ROOF
SHAKES
SHAKE MFR'S STANDARD
RIDGE VENT
SYNTHETIC RIDGE SHAKE
CONTINUOUS
INSECT SCREEN
2X BLOCKING
EACH SIDE OF
RIDGE
METAL FASCIA PANELS - SAME
VERTICAL DIMENSION AT
EAVE AND RAKE
EAVE AND RAKE PANELS
SQUARE TO EACH OTHER.
USE CORNER PANEL AT EAVE
TO RAKE CONNECTIONS
.0
90.00°
90.
EAVES CUT SQUARE TO ROOF
SLOPE
ROOF STRUCTURE BELOW
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A112
ROOF DETAILS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1 1/2" = 1'-0"A112
1 RIDGE VENT
NOT TO SCALEA112
2 ROOF CORNER DETAIL
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
NATURAL STONE
VENEER
FIBER CEMENT SIDING
BOARD AND BATTEN
FIBER CEMENT SIDING
LAP
MATERIALS LEGEND
SYNTHETIC ROOF
SHAKES
METAL FASCIA PANEL
FIRST FLOOR
100'-0"
A304
_______________ 1
A305
_______________2
A307
_______________ 1
A306
EJ
PLYWD PANEL -
PAINT - SEE A600
SHEETS
A104
A104
A203
A203
SIM
/8
/8
/8
B D C
A104
MECH & ELEC EQUIPMENT -
SEE MECH. & ELEC.
SEE A318 FOR WALL
MOUNTED COMPONENTS
A203
TYP
P.E.F.S
BACKER ROD
SANDED SEALANT
1/2"
/2
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A201
EXTERIOR ELEVATIONS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/4" = 1'-0"A201
1 MAIN BUILDING NORTH ELEVATION
3" = 1'-0"A201
2 MASONRY EXPANSION JOINT
EXTERIOR FINISHES NOTE:
FIELD PAINT EXPOSED WOOD RAFTER TAILS AND
STRUCTURE, FIBER-CEMENT SIDING & TRIM, METAL
SURFACES THAT ARE NOT PRE-FINISHED, AND AS
OTHERWISE NOTED.
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
FIRST FLOOR
100'-0"
A304
A305
A307
A306
EJ
PLYWD PANEL - PAINT -
SEE A600 SHEETS
A104
_______________ 3
A104
A203
E A C
A104
A104
A203
TYP
5" 5"
/8
/8
/8
/8
1 1/4"
1 1/4"
DRIP DRIP
WATER TABLE WINDOW SILL
NATURAL STONE
VENEER
FIBER CEMENT SIDING
BOARD AND BATTEN
FIBER CEMENT SIDING
LAP
MATERIALS LEGEND
SYNTHETIC ROOF
SHAKES
METAL FASCIA PANEL
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A202
EXTERIOR ELEVATIONS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it 1/4" = 1'-0"A202
1 MAIN BUILDING SOUTH ELEVATION
1 1/2" = 1'-0"A202
2 PRECAST CONCRETE PROFILES
EXTERIOR FINISHES NOTE:
FIELD PAINT EXPOSED WOOD RAFTER TAILS AND
STRUCTURE, FIBER-CEMENT SIDING & TRIM, METAL
SURFACES THAT ARE NOT PRE-FINISHED, AND AS
OTHERWISE NOTED.
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A301
_______________ 1
A303
_______________1
A302
_______________1
A307
RUN WINDOW HEAD TRIM
CONTINUOUS THROUGH
WEST FACE OF BUILDING
A104
A204
NPS SIGNAGE
LOCATION
F A A A A A A F
A104
A203
TYP
NATURAL STONE
VENEER
FIBER CEMENT SIDING
BOARD AND BATTEN
FIBER CEMENT SIDING
LAP
MATERIALS LEGEND
SYNTHETIC ROOF
SHAKES
METAL FASCIA PANEL
SEAL FLASHING
LEG INTO SAM
FIBER CEMENT LAP
SIDING
WD FURRING
STRIPS
STARTER STRIP
Z FLASHING
1/4" GAP - NO
SEALANT
INSECT SCREEN
PRECAST
CONCRETE SILL -
WATER TABLE SIM
NATURAL STONE
VENEER
2 1/2" X 3/4" FIBER CEMENT
BATTEN TRIM BOARDS AT 16"
O.C.. MECHANICALLY FASTEN
THROUGH FIBER CEMENT
PANELS AND BACK TO WOOD
FURRING STRIPS
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A203
EXTERIOR ELEVATIONS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/4" = 1'-0"A203
1 MAIN BUILDING WEST ELEVATION
3" = 1'-0"A203
PRECAST SILL TO LAP
SIDING (WATER TABLE SIM)
EXTERIOR FINISHES NOTE:
FIELD PAINT EXPOSED WOOD RAFTER TAILS AND
STRUCTURE, FIBER-CEMENT SIDING & TRIM, METAL
SURFACES THAT ARE NOT PRE-FINISHED, AND AS
OTHERWISE NOTED.
3" = 1'-0"A203
3 BATTEN DETAIL
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A301
_______________1
A303
_______________ 1
A302
_______________ 1
A307
A104
A204
FF
A104
FIRE EQUIPMENT - SEE
FIRE. SEE A318 FOR WALL
MOUNTED COMPONENTS
FIRE & PLUMBING
PENETRATIONS - SEE FIRE.
& PLUMB. SEE A318 FOR
PENETRATION DETAILS
A203
TYP
NATURAL STONE
VENEER
FIBER CEMENT SIDING
BOARD AND BATTEN
FIBER CEMENT SIDING
LAP
MATERIALS LEGEND
SYNTHETIC ROOF
SHAKES
METAL FASCIA PANEL
SEAL FLASHING
LEG INTO SAM
FIBER CEMENT
PANEL SIDING
WD FURRING
STRIPS
Z FLASHING
1/4" GAP - NO
SEALANT
INSECT SCREEN
PRECAST
CONCRETE SILL
NATURAL STONE
VENEER
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A204
EXTERIOR ELEVATIONS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it 1/4" = 1'-0"A204
1 MAIN BUILDING EAST ELEVATION
3" = 1'-0"A204
PRECAST SILL AT
BOARD & BATTEN SIDING
EXTERIOR FINISHES NOTE:
FIELD PAINT EXPOSED WOOD RAFTER TAILS AND
STRUCTURE, FIBER-CEMENT SIDING & TRIM, METAL
SURFACES THAT ARE NOT PRE-FINISHED, AND AS
OTHERWISE NOTED.
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A308
F
MECH EQUIPMENT -
SEE MECH.
FIRST FLOOR
100'-0"
A308
D
MECH & ELEC EQUIPMENT -
SEE MECH. & ELEC.
SEE A318 FOR WALL
MOUNTED COMPONENTS
A203
TYP
NATURAL STONE
VENEER
FIBER CEMENT SIDING
BOARD AND BATTEN
FIBER CEMENT SIDING
LAP
MATERIALS LEGEND
SYNTHETIC ROOF
SHAKES
METAL FASCIA PANEL
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A205
EXTERIOR ELEVATIONS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/4" = 1'-0"A205
1 KIOSK WEST ELEVATION
1/4" = 1'-0"A205
2 KIOSK NORTH ELEVATION
EXTERIOR FINISHES NOTE:
FIELD PAINT EXPOSED WOOD RAFTER TAILS AND
STRUCTURE, FIBER-CEMENT SIDING & TRIM, METAL
SURFACES THAT ARE NOT PRE-FINISHED, AND AS
OTHERWISE NOTED.
ELEVATIONS SHOWN ARE FOR BOTH THE NORTH AND SOUTH KIOSKS. ELEVATIONS SHOWN ARE FOR BOTH THE NORTH AND SOUTH KIOSKS.
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A308
MECH & ELEC EQUIPMENT -
SEE MECH. & ELEC.
SEE A318 FOR WALL
MOUNTED COMPONENTS
FIRST FLOOR
100'-0"
A308
PLYWD PANEL - PAINT -
SEE A600 SHEETS
D
A203
TYP
NATURAL STONE
VENEER
FIBER CEMENT SIDING
BOARD AND BATTEN
FIBER CEMENT SIDING
LAP
MATERIALS LEGEND
SYNTHETIC ROOF
SHAKES
METAL FASCIA PANEL
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A206
EXTERIOR ELEVATIONS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/4" = 1'-0"A206
1 KIOSK EAST ELEVATION
1/4" = 1'-0"A206
2 KIOSK SOUTH ELEVATION
EXTERIOR FINISHES NOTE:
FIELD PAINT EXPOSED WOOD RAFTER TAILS AND
STRUCTURE, FIBER-CEMENT SIDING & TRIM, METAL
SURFACES THAT ARE NOT PRE-FINISHED, AND AS
OTHERWISE NOTED.
ELEVATIONS SHOWN ARE FOR BOTH THE NORTH AND SOUTH KIOSKS. ELEVATIONS SHOWN ARE FOR BOTH THE NORTH AND SOUTH KIOSKS.
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A304
_______________1
A305
_______________ 2
A307
_______________1
A306
A309
107 105 104 102 101
T.O. FOOTING
95'-9 1/4"
SEE ENV AND STRUCT
FOR BACKFILL AND
RADON ASSEMBLY
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A301
MAIN BUILDING SECTIONS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/4" = 1'-0"A301
1 EAST WEST BUILDING SECTION 1
BT A
ATE OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A304
_______________1
A305
_______________ 2
A307
_______________1
A306
108 105 103 112
A309
TYP
A312
T.O. FOOTING
95'-9 1/4"
SEE ENV AND STRUCT
FOR BACKFILL AND
RADON ASSEMBLY
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A302
MAIN BUILDING SECTIONS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/4" = 1'-0"A302
1 EAST WEST BUILDING SECTION 2
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A304
A305
A307
A306
A310
T.O. FOOTING
95'-9 1/4"
SEE STRUCT FOR BACKFILL
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A303
MAIN BUILDING SECTIONS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/4" = 1'-0"A303
1 EAST WEST BUILDING SECTION 3
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A301
_______________1
A303
_______________ 1
A302
_______________ 1
A307
A309
TYP
104 103 110
T.O. FOOTING
95'-9 1/4"
SEE ENV AND STRUCT FOR
BACKFILL AND RADON ASSEMBLY
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A304
MAIN BUILDING SECTIONS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/4" = 1'-0"A304
1 NORTH SOUTH BUILDING SECTION 1
BT A
ATE OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A301
A303
_______________1
A302
A307
A309
108 107
T.O. FOOTING
95'-9 1/4"
GRATE AT DOOR - SEE
STRUCT
SEE ENV AND STRUCT FOR
BACKFILL AND RADON ASSEMBLY
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A305
MAIN BUILDING SECTIONS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/4" = 1'-0"A305
1 NORTH SOUTH BUILDING SECTION 2
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A301
A303
_______________1
A302
A307
A310
109 105 106
T.O. FOOTING
95'-9 1/4"
SEE ENV AND STRUCT FOR
BACKFILL AND RADON ASSEMBLY
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A306
MAIN BUILDING SECTIONS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/4" = 1'-0"A306
1 NORTH SOUTH BUILDING SECTION 3
BT A
ATE OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
T ectonic Cop yright 2007T ectonic Cop yright 2007T ectonic Cop yright 2007
T ectonic Cop yright 2007T ectonic Cop yright 2007
FIRST FLOOR
100'-0"
T.O. FOOTING
95'-9 1/4"
FIRST FLOOR
100'-0"
A307
_______________1
A306
A311
A311
T.O. FOOTING
95'-9 1/4"
FIRST FLOOR
100'-0"
T.O. FOOTING
95'-9 1/4"
FIRST FLOOR
100'-0"
T.O. FOOTING
95'-9 1/4"
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A307
BUILDING SECTIONS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/8" = 1'-0"A307
2 NORTH SOUTH SITE SECTION
1/4" = 1'-0"A307
1 EAST WEST BUILDING SECTION 4 - TRANSACTION WINDOW
SITE SHOWN FOR REFERENCE ONLY. SEE SHEETS A101 AND A102 FOR ACTUAL FLOOR ELEVATIONS OF EACH BUILDING.
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A308
A313
T.O. FOOTING
95'-9 1/4"
SEE A320 FOR
ACCESS LADDER
AND FLOOR DOOR
FIRST FLOOR
100'-0"
A308
A313
T.O. FOOTING
95'-9 1/4"
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :0
A
M A308
KIOSK SECTIONS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1/4" = 1'-0"A308
1 EAST WEST KIOSK SECTION
1/4" = 1'-0"A308
2 NORTH SOUTH KIOSK SECTION
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
A307
T.O. FOOTING
95'-9 1/4"
A
A319
A107
B
C
FIRST FLOOR
100'-0"
C
B
T.O. FOOTING
95'-9 1/4"
A
A319
A109
N
P S Y E L L
M T
P R O
J E C T
S T A T E
S H
E E T
N U
M B E R
N P S P
M
IS
N o . 1
D
N P S D rw g . N o . 1
3/2/2020 9:24:09 AM
A
M A
I N
B U
I L D
I N
G W
A L L
S E C
T I O
N S
Checked by:ANDERSONDrawn by:MORTENSONL:\YNP\YNPNES_02\BIMCAD\Revit
1/2" = 1'-0"A309
1 WALL SECTION
1/2" = 1'-0"A309
2 WALL SECTION
B
T
A
AT
E
O F
M O
N T
AN
LICE
N S
E D
A R
C H
IT
ECT
T Y
L E
R R
O B
E R
T M
O R
T E
N S
O N
I L L
IN
G
S
S
M A
O N
T A
N
C
B
T.O. FOOTING
95'-9 1/4"
A
A319
A110
/8
/8
A104
FIRST FLOOR
100'-0"
C
B
T.O. FOOTING
95'-9 1/4"
A
A319
N
P S Y E L L
M T
P R O
J E C T
S T A T E
S H
E E T
N U
M B E R
N P S P
M
IS
N o . 1
D
N P S D rw g . N o . 1
3/2/2020 9:24:09 AM
A
M A
I N
B U
I L D
I N
G W
A L L
S E C
T I O
N S
Checked by:ANDERSONDrawn by:MORTENSONL:\YNP\YNPNES_02\BIMCAD\Revit
1/2" = 1'-0"A310
1 WALL SECTION
1/2" = 1'-0"A310
2 WALL SECTION
B
T
A
AT
E
O F
M O
N T
AN
LICE
N S
E D
A R
C H
IT
ECT
T Y
L E
R R
O B
E R
T
M O
R T
E N
S O
N
I L L
IN
G
S
S
M A
O N
T
C
B
T.O. FOOTING
95'-9 1/4"
A
A319
/8
/8
FIRST FLOOR
100'-0"
C
B
T.O. FOOTING
95'-9 1/4"
A
A319
/8
/8
N
P S Y E L L
M T
P R O
J E C T
S T A T E
S H
E E T
N U
M B E R
N P S P
M
IS
N o . 1
D
N P S D rw g . N o . 1
3/2/2020 9:24:10 AM
A
M A
I N
B U
I L D
I N
G W
A L L
S E C
T I O
N S
Checked by:ANDERSONDrawn by:MORTENSONL:\YNP\YNPNES_02\BIMCAD\Revit
1/2" = 1'-0"A311
1 WALL SECTION
1/2" = 1'-0"A311
2 WALL SECTION
B
T
A
AT
E
O F
M O
N T
AN
LICE
N S
E D
A R
C H
IT
ECT
T Y
L E
R R
O B
E R
T
M O
R T
E N
S O
N
I L L
IN
G
S
S
M A
O N
T
B
C
T.O. FOOTING
95'-9 1/4"
A
A319
A203
SIM
A109
/8
N
P S Y E L L
M T
P R O
J E C T
S T A T E
S H
E E T
N U
M B E R
N P S P
M
IS
N o . 1
D
N P S D rw g . N o . 1
3/2/2020 9:24:10 AM
A
M A
I N
B U
I L D
I N
G W
A L L
S E C
T I O
N S
Checked by:ANDERSONDrawn by:MORTENSONL:\YNP\YNPNES_02\BIMCAD\Revit
1/2" = 1'-0"A312
1 WALL SECTION
B
T
A
AT
E
O F
M O
N T
AN
LICE
N S
E D
A R
C H
IT
ECT
T Y
L E
R R
O B
E R
T
M O
R T
E N
S O
N
I L L
IN
G
S
S
M A
O N
T
C
B
T.O. FOOTING
95'-9 1/4"
A
A319
A111
FIRST FLOOR
100'-0"
T.O. FOOTING
95'-9 1/4"
B
C
A
A319
A111
N
P S Y E L L
M T
P R O
J E C T
S T A T E
S H
E E T
N U
M B E R
N P S P
M
IS
N o . 1
D
N P S D rw g . N o . 1
3/2/2020 9:24:10 AM
A
K I O
S K
W A
L L S
E C
T I O
N S
Checked by:ANDERSONDrawn by:MORTENSONL:\YNP\YNPNES_02\BIMCAD\Revit
1/2" = 1'-0"A313
1 WALL SECTION
1/2" = 1'-0"A313
2 WALL SECTION
B
T
A
AT
E
O F
M O
N T
AN
LICE
N S
E D
A R
C H
IT
ECT
T Y
L E
R R
O B
E R
T
M O
R T
E N
S O
N
I L L
IN
G
S
S
M A
O N
T
START
STEP 3 - INSTALL "DOG-BONE" S.A.M. PATCHES AT UPPER CORNERS (HEAD)
CUT MIN. 6 IN. LONG BY 3 IN. WIDE DOG BONE SHAPED PATCHES OF S.A.M. (MIN. 1
IN. WIDE AT CENTER) AND INSTALL AT BOTH TOP CORNERS OF THE ROUGH
OPENING. PRESS THE PATCH INTO THE CORNER TO CREATE A TIGHT SEAL AND
PREVENT THE PATCH FROM BRIDGING AT ALL 90 DEGREE SUBSTRATE ANGLE
CHANGES.
STEP 2 - SURFACE PREP
CLEAN, PREP AND PRIME SHEATHING AND AREAS OF THE ROUGH
OPENING THAT WILL RECEIVE FLASHING AND S.A.M., PER S.A.M.
MANUFACTURERS REQUIREMENT USING RECOMMENDED PRIMERS
AND/OR ADHESIVES.
STEP 1 - CUT THE FLASHING STIPS FROM S.A.M. MEMBRANE
ROUGH OPENING + 12"
MIN
ROUGH OPENING
WIDTH - CUT SLITS AT
BOTH END HEAD/SILL
FLASHING
6" MIN 6" MIN
VIEW FROM BELOW THE WINDOW HEAD
MIN. 1 IN. WIDE AT CENTER NOTCH
TIPS TO FACILITATE INSTALLATION
A. PRE-FOLD FLASHING INTO ROUGH OPENING
WITH RELEASE LINER STILL IN PLACE.
B. REMOVE RELEASE LINER FROM BACK SIDE
OF FLASHING AND ROLL FIRMLY INTO PLACE.
C. USE A V SHAPED ROLLER TO PRESS THE
FLASHING INTO THE CORNERS OF THE
OPENING.
STEP 5 - SECURE TOP OF HEAD FLASHING
IN THE TOP 1" OF THE FLASHING LEG, SECURE TOP EDGE OF
HEAD FLASHING WITH ROOFING NAILS AT 12" O.C. TO HOLD IT
IN PLACE UNTIL WALL S.A.M. IS INSTALLED. DO NOT USE
STAPLES.
STEP 4 - INSTALL HEAD FLASHING
FOLD S.A.M. FLASHING
ONTO WALL, OVER
DOG-BONE PATCHES,
AND ADHERE TO
SHEATHING
SHEATHING
ROUGH
OPENING
STEP 6 - INSTALL S.A.M. ON WALL SHEATHING
STRIP S.A.M. IN VERTICALLY BEGINNING AT THE TOP OF
THE WALL WORKING DOWNWARD PER S.A.M.
MANUFACTURE'S INSTALLATION INSTRUCTIONS. SHINGLE-
LAP END JOINTS 3" MIN. LAP SIDE JOINTS 3" MIN. CUT
WALL S.A.M. TO MATCH EDGES OF ROUGH OPENING.
ROUGH OPENING + 12" MIN. AT WINDOWS
ROUGH OPEING + 6" MIN. AT DOORS
ROUGH OPENING JAMB
FLASHING6" MIN 6" MIN
FIRST ADHERE S.A.M.
FLASHING TO HEAD AND SIDES
OF ROUGH OPENING.
3" MIN
DEPTH OF WALL
FRAMING + SHEATHING
3" MIN
DEPTH OF WALL
FRAMING +
SHEATHING
OMIT NOTCH AT
DOOR FLASHINGS
BEVEL TOP EDGE
OF JAMB FLASHING
PRESS FLASHING
TIGHTLY INTO
CORNERS WITH V-
SHAPED ROLLER
1"
12" O.C.
NOTE: DOOR FLASHING SIMILAR EXCEPT OMITS SILL FLASHING. SEE DOOR DETAILS FOR THRESHOLD DETAILS
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :1
A
M A314
SAM DETAILS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
NOT TO SCALEA314
2 OPENING FLASHING DETAILS STEP 1 - 6
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
S.A.M. ON
SHEATHING
STEP 7 - INSTALL THE SILL FLASHING IN WINDOW R.O.'S
ROUGH
WINDOW
OPENING
STEP 8 - INSTALL "DOG-BONE" S.A.M. PATCHES AT LOWER CORNERS OF WINDOW R.O.
S.A.M. ON
SHEATHING
ROUGH
WINDOW
OPENING
FOLD S.A.M. FLASHING
LEG ONTO WALL AND
ADHERE TO WALL
S.A.M.
START
CUT MIN. 6 IN. LONG BY 3
IN. WIDE DOG BONE
SHAPED PATCHES OF
FLASHING (MIN. 1 IN.
WIDE AT CENTER) AND
INSTALL OVER BOTH
BOTTOM CORNERS OF
THE SILL FLASHING.
PRESS THE PATCH INTO
THE CORNER TO CREATE
A TIGHT SEAL AND
PREVENT THE PATCH
FROM BRIDGING AT ALL
90 DEGREE SUBSTRATE
ANGLE CHAGES.
FIRST ADHERE S.A.M.
FLASHING TO JAMB OF
ROUGH OPENING
ROUGH
OPENIN
GSTART
S.A.M. ON
SHEATHING
FOLD ONTO WALL
OVER SAM
STEP 9 - INSTALL THE JAMB FLASHING
MIN. 1 IN.
MIN. 3 IN.
M
IN
I N
MIN.
1 IN.
WIDE
SILL
FLASHING
END DAMS
6"
FIRST ADHERE SILL
FLASHING AND END DAMS
TO SILL AND JAMB OF
ROUGH OPENING.
FOLD S.A.M. FLASHING
ONTO WALL AND
AHDERE TO WALL S.A.M.
NOTE: DOOR FLASHING SIMILAR EXCEPT OMITS SILL FLASHING. SEE DOOR DETAILS FOR THRESHOLD DETAILS
PRESS FLASHING
TIGHTLY INTO
CORNERS WITH V-
SHAPED ROLLER
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :1
A
M A315
SAM DETAILS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
NOT TO SCALEA315
1 OPENING FLASHING DETAILS STEP 7 - 9
BT A
ATE OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
LAP WALL S.A.M. OVER WINDOW
HEAD FLASHING 3" MIN.
LAP JAMB FLASHING
OVER WALL S.A.M. 3"
MINIMUM
LAP SILL FLASHING OVER
WALL S.A.M. 3" MINIMUM
3" MIN. SIDE LAPS ON
WALL S.A.M.
STEP 10 - SEAL TOP OF JAMB FLASHING
SEAL TOP EDGE OF JAMB FLASHING WITH S.A.M.
MFR'S RECOMMENDED TERMINATION
MASTIC/SEALANT.
SEAL TOP EDGE OF
JAMB FLASHING
3" MIN. SHINGLE-LAP
END LAPS (IF ANY)
ROUGH
OPENIN
G
1ST LAYER:
UPPER DOG-BONES
2ND LAYER:
HEAD FLASHING
3RD LAYER:
WALL S.A.M.
4TH LAYER:
SILL FLASHING
5TH LAYER:
LOWER DOG-BONES
6TH LAYER:
JAMB FLASHING ROUGH
WINDOW
OPENING
- DOOR
SIM.
S.A.M. ON
SHEATHING
SEAL "T" JOINTS PER S.A.M.
MFR'S INSTRUCTIONS
NOTE: DOOR FLASHING SIMILAR EXCEPT OMITS SILL FLASHING. SEE DOOR DETAILS FOR THRESHOLD DETAILS
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :1
A
M A316
SAM DETAILS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
NOT TO SCALEA316
1 OPENING FLASHING DETAILS STEP 10
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
E
N E
T R
A T
IO
N
C
IR
C U
M F
E R
E N
C E
3" MIN. 3" MIN.
FINGER FLASHING FABRICATED
FROM S.A.M. MEMBRANE
1 - PENETRATION 3 - AFTER FOAM IS
CURED, SHAVE FLUSH
WITH FACE OF
SHEATHING
5 - INSTALL S.A.M.
BELOW
PENETRATION, OVER
FINGER FLASHING
.25 X PENETRATION DIA.
OR 1/2" MIN.
2 - FILL ANNULAR SPACE
AROUND PENETRATION WITH
APPROVED SEALANT. FILL
LARGER OR ROUGH GAPS WITH
SPRAY FOAM
4 - PREP SHEATHING AND
INSTALL FINGER FLASHING
AROUND PENETRATION
AS SHOWN
7 - SEAL TERMINATION AND
PENETRATION BASE WITH
APPROVED SEALANT
6 - INSTALL S.A.M. ABOVE
PENETRATION. LAP
OVER LOWER S.A.M. 3"
MIN
CUT LINES
GENERAL NOTE: THE TERM "PENETRATION" APPLIES TO ALL PENETRATIONS, CYLINDRICAL OR RECTANGULAR, THRU THE S.A.M. INCLUDING, PIPES, CONDUITS, DUCTS, ETC...
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :1
A
M A317
SAM DETAILS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
NOT TO SCALEA317
1 PENETRATION FLASHING DETAILS PRIOR TO SAM INSTALLATION
BT A
ATE OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
3/4" PLYWD BLOCKING AT
PENETRATION - PAINT TO
MATCH FIBER CEMENT SIDING
FIBER CEMENT LAPPED
SIDING - PANEL SIDING SIM
SEAL SAM TO
PENETRATION - SEE 1/A317
SEALANT AROUND
PERIMETER OF PENETRATION
PENETRATION
FIBER CEMENT TRIM BOARDS -
ALL SIDES OF BLOCKING
BLOCKING
AS REQ'D
SPRAY
FOAM
FLASHING
A3182
FIBER CEMENT LAPPED
SIDING - PANEL SIDING SIM
FLASHING
FIBER CEMENT TRIM
BOARDS - PAINT
3/4" PLYWD BLOCKING -
PAINT
PENETRATION
3/4" PLYWD BLOCKING AT
EQUIPMENT - PAINT TO MATCH
FIBER CEMENT SIDING
FIBER CEMENT LAPPED
SIDING - PANEL SIDING SIM
BUILDING MOUNTED
EQUIPMENT - SEE MECH,
ELEC, FIRE, ELEVATIONS
FIBER CEMENT TRIM BOARDS -
ALL SIDES OF BLOCKING
BLOCKING
AS REQ'D
FLASHING
A3184
FIBER CEMENT LAPPED
SIDING - PANEL SIDING SIM
FLASHING
FIBER CEMENT TRIM
BOARDS - PAINT
3/4" PLYWD BLOCKING -
PAINT
BUILDING MOUNTED
EQUIPMENT - SEE MECH,
ELEC, FIRE, ELEVATIONS
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :1
A
M A318
SECTION DETAILS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1 1/2" = 1'-0"A318
1 WALL PENETRATIONS
1 1/2" = 1'-0"A318
2 WALL PENETRATIONS ELEVATION
1 1/2" = 1'-0"A318
3 EQUIPMENT MOUNTING
1 1/2" = 1'-0"A318
4 EQUIPMENT MOUNTING ELEVATION
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
T.O. FOOTING
95'-9 1/4"
SEAL SAM OVER
FLEXIBLE
FLASHING 8" MIN.
WALL SAM VAPOR
BARRIER
NATURAL STONE
VENEER
MORTAR NET
4" CMU - SEE
STRUCT.
GROUT COLLAR
JOINT FULL
2" RIGID
INSULATION
CONCRETE
FOUNDATION
WALL - SEE
STRUCT.
SILL SEAL - TYP.
WEEPS
FLEXIBLE FLASHING
SEAL SAM TO FACE
OF FOUNDATION
12" MIN
FIRST FLOOR
100'-0"
T.O. FOOTING
95'-9 1/4"
SEAL SAM OVER
FLEXIBLE
FLASHING 8" MIN.
WALL SAM
NATURAL STONE
VENEER
MORTAR NET
4" CMU - SEE
STRUCT.
GROUT COLLAR
JOINT FULL
2" RIGID
INSULATION
CONCRETE
FOUNDATION
WALL - SEE
STRUCT.
SILL SEAL - TYP.
WEEPS
FLEXIBLE FLASHING
SEAL SAM TO FACE
OF FOUNDATION
12" MIN
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :1
A
M A319
SECTION DETAILS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1 1/2" = 1'-0"A319
1 BASE OF STONE VENEER AT GRADE
1 1/2" = 1'-0"A319
2 BASE OF STONE VENEER AT CURB
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
T.O. FOOTING
95'-9 1/4"
FLOOR DOOR - SEE
SPECS
FLOOR JOISTS - SEE
STRUCT.
SLOPED ACCESS
LADDER - PAINT W/ 2
COATS ZINC OXIDE
PRIMER
NON-SLIP RUNGS
3'-0" x 3'-0" x 6"
CONCRETE SLAB AT
BASE OF LADDER
A320
FIRST FLOOR
100'-0"
T.O. FOOTING
95'-9 1/4"
A320
FLOOR DOOR - SEE
SPECS
FLOOR JOISTS - SEE
STRUCT.
SLOPED ACCESS
LADDER - PAINT W/ 2
COATS ZINC OXIDE
PRIMER
NON-SLIP RUNGS
3'-0" x 3'-0" x 6"
CONCRETE SLAB AT
BASE OF LADDER
4"
___NPS_YELL_11(2)___MT
PROJECTSTATE
SHEET
NUMBER
NPS PMIS No. 177136D
NPS Drwg. No. 101/109186
/2
/2
:2 :1
A
M A320
SECTION DETAILS
C h e c k e d b y :A
N D
E R
S O
N D ra w n b y :M
O R
T E N
S O
N L
Y N
P \Y
N P N
E S \B
IM
C
A D
\R e v it
1" = 1'-0"A320
1 CRAWL SPACE ACCESS LADDER
1" = 1'-0"A320
2 ACCESS LADDER SECTION
BT A
ATE
OF MONTAN
L
IC
E
N
SED ARCHIT
E C
T16071
TYLER ROBERT
MORTENSON
I LLINGS
FLOORING
BASE
RB#…