240143_SOW-Att2_Environmental_Inspection_Report.pdf

PDF 3 MB Posted

Attached to
TINKER AFB MACBOA WWYK240143 REPLACE ROOFS - B1105, B3812, B467
Solicitation number
WWYK240143
Issued by

About this file

This document is an Asbestos/LBP (Lead-Based Paint) Inspection Report for a roof replacement project at Tinker Air Force Base involving Buildings 467, 1105, and 3812, constructed between 1983-1990. The laboratory analysis by QuantTEM Laboratories reveals that while Building 467 has no asbestos present in its roofing materials, Buildings 1105 and 3812 contain asbestos in their black/gray roof tar and compound sections. Specifically, the report identifies multiple samples with asbestos present, with chrysotile asbestos ranging from 5-10% in some tar samples.

The inspection recommends Class II abatement work for the roof tar associated with Buildings 1105 and 3812, and advises following all demolition notification, practices, and procedures under Asbestos NESHAP, OSHA, and ODOL regulations. The samples were collected on 7 August 2024, with the roofing materials described as having "some damage" and categorized as Asbestos Containing Material (ACM) Category I, Non-Friable (NF). The visual inspection noted noticeable weather damage on the roofs, and the analysis was conducted using Polarized Light Microscopy (PLM) to determine asbestos content.

View the file

Other files

File Type Posted
240143_Consolidated_pre-bid_RFI_proposed-responses_COR.pdf PDF
Solicitation Amendment FA813725R00310002 SF 30.pdf PDF
Solicitation Amendment FA813725R00310001 SF 30.pdf PDF
Att2_240143_Drawings.pdf PDF
Solicitation - FA813725R0031.pdf PDF
Attachment 1 - Statement of Work.pdf PDF
Attachment 4 - Wage Determination OK20250049.pdf PDF
Attachment 3 - Submittal Register.pdf PDF
00 71 00.pdf PDF
26 20 00.pdf PDF
Att12_240143_Drawings.pdf PDF
00 70 00.pdf PDF
DACA56-86-C-0074.pdf PDF
07 60 00.pdf PDF
07 53 23.pdf PDF
Att11_240143_Submittal_Register.pdf PDF
01 42 00.pdf PDF
00 80 05.pdf PDF
2020 TAFB Facility Standard.pdf PDF
01 33 00.pdf PDF
01105_RoofSections.pdf PDF
07 54 19.pdf PDF
01 78 23.pdf PDF
DACA56-87-C-0025.pdf PDF
01 32 16.00 20.pdf PDF
01 78 00.pdf PDF
06 10 00.pdf PDF
00 72 00.pdf PDF
01 50 00.pdf PDF
07 92 00.pdf PDF
DACA56-89-C-0015.pdf PDF
2020 TAFB Mechanical Standard.pdf PDF
01 45 00.00 10.pdf PDF
EAL information sheet.xlsx XLSX spreadsheet
02 41 00.pdf PDF
00 80 00.pdf PDF
2023 TAFB Fire Protection Standard.pdf PDF
2024 TAFB Electrical Standards.pdf PDF
26 41 00.pdf PDF
07 22 00.pdf PDF
Att10_240143_MAC-B_Roof_SOW.pdf PDF
01 33 16.00 10.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

72 ABW/CEIE

ABSESTOS/LBP INSPECTION REPORT PAGE 1 OF 10

Project Information

Project Name Replace Multiple Roofs Project ID WWYK240143

Project Building 467, 1105, 3812 Year Constructed 1990; 1983; 1989

Room/Post Location Roofs Historical Samplings No

Requestor Neal Birchum Inspector(s) Laura Duck; Michael Green

Inspection Date 7 Aug 2024 Report Prepared By

Sampling Information:

Sample ID - Location Material/Dimensions Classification Condition Hazard Friable Analysis Results

RM46700001

N Roof

Black Roofing Material

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Not Present

RM46700002

S Roof

Black Roofing Material

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Not Present

RM46700003

E Roof

Black Roofing Material

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Not Present

RM46700004

W Roof

Black Roofing Material

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Not Present

RM11050001

N Roof

Black Roofing Material

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Not Present

RM11050002

S Roof

Black Roofing Material

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Not Present

RM11050003

E Roof

Black Roofing Material

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Not Present

RM11050004

W Roof

Black Roofing Material

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Not Present

RM11050005

Center Roof

Black Roofing Material

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Not Present

RM11050006

Sides of Roof

Black Roofing Material/Tar

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Present

RM38120001

N Roof

Black Roofing Material/Compound/Tar

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Present

RM38120002

S Roof

Black Roofing Material

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Present

RM38120003

W Roof

Black Roofing Material

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Not Present

Page | 2

Sample ID - Location Material/Dimensions Classification Condition Hazard Friable Analysis Results

RM38120004

E Roof

Black Roofing Material

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Present

RM38120005

Center Roof

Black Roofing Material

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Present

RM38120006

Sides

Black Roofing Material/Compound

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Present

RM38120007

W Center Roof

Black Roofing Material

>160 sqft

Misc Some Damage

ACM Cat I NF PLM Asbestos Not Present

Visual Observations/Photos (if available)

• CEIE performed a physical inspection of each roof. The roofs contained noticeable weather damage. CEIE inspected roofing materials only and no interior materials.

BLDG 467 BLDG 1105 BLDG 3812

General Inspection Procedures:

• CEIE conducted a visual and physical inspection of the roofing materials and extracted multiple samples for asbestos analysis.

Condition:

Surfacing/Misc. Materials:

• Good Condition: Material with no visible damage or deterioration or showing only very limited damage or deterioration.

• Some Damage: Material crumbling, blistered, water-stained, gouged, marred, or abraded covering less than one tenth of the surface if the damage is evenly distributed (one quarter if the damage is localized).

• Significant Damage: Material crumbling, blistered, hanging from surface, deteriorated, adhesive failure, water-stained, gouged, marred, or abraded covering more than one tenth if the damage is evenly distributed (one quarter if the damage is localized).

Thermal System Insulation:

• Good Condition: Material with no visible damage or deterioration.

• Damage/Significant Damage: Material that has lost its structural integrity, its covering, in whole or in part, is crushed, water-stained, gouged, punctured, or not intact such that is not able to contain fibers.

Note: There is only one category of damage for TSI: Damaged or significantly damaged”.

Page | 3

Hazard:

• ACM = Asbestos Containing Material; defined by the EPA as any material containing more than 1 percent asbestos.

• LBP = Lead-Based Paint; defined by the EPA as paint with lead levels greater than or equal to 1.0 milligram per square centimeter

(mg/cm2), or more than 0.5% by weight.

Friable:

• Friable = Material, when dry, may be crumbled, pulverized, or reduced to powder by hand pressure, and includes previously nonfriable material that becomes damaged to the extent that it is now friable.

• NF = Nonfriable; Material, when dry may not be crumbled, pulverized, or reduced to powder by hand pressure.

Analysis/Results:

• PLM = Polarized Light Microscopy; Asbestos Present or Asbestos Not Present

• PACM = Presumed Asbestos Containing Material; TSI and SM found in buildings constructed no later than 1980.

• XRF = X-ray Fluorescence

• The XRF spectrometry identifies if lead is present and the quantifies the amount of lead present.

a. Pass = results for Pb are lower than the limit parameter (less than 1 mg/cm2)

b. Inconclusive = Quantitive analysis in the region defined as intermediate. Additional investigation performed with Pb check sticks.

c. Fail = Results for Pb are higher than the limit parameter (greater than 1 mg/cm2)

d. ND = Pb not detected

• Pb Stick = Lead Paint Check Stick; Qualitative analysis that determines if LBP is present on surfaces.

Summary of ACMs:

• The black and gray roof tar for B.1105, and B.3812 contain greater than 1% asbestos. See PLM for percentages.

Summary of LBPs:

• XRF analysis did or did not detect LBP.

Conclusions:

• B.467 Asbestos Not Present in roofing materials.

• B.1105, only the black/gray tar contains asbestos. No asbestos present in other roofing materials.

• B.3812, only the black/gray tar contains asbestos. No asbestos present in other roofing materials.

Recommendations:

• Based on the information collected during this inspection, the following recommendations are offered. These recommendations are based on currently observed conditions of only asbestos containing materials and painted surfaces that contain lead, and may have to be adjusted if emergency, or other factors alter the condition, use, or planned future use.

• Class II abatement work of the roof tar associated with buildings 1105 and 3812.

• Follow all demolition notification, practices, and procedures under Asbestos NESHAP, OSHA and ODOL, as applicable.

• Contact CEIE at 72abw.ce.asbestos-lbp@us.af.mil for any questions or if additional suspect materials are discovered.

mailto:72abw.ce.asbestos-lbp@us.af.mil

Page | 4

PLM Analysis and CoC: Page 4 through 10

Page | 5

Page | 6

Page | 7

Page | 8

Page | 9

Page | 10

END OF REPORT

ABSESTOS/LBP inspection report Page 1 of 10
Project Information
Sampling Information:
Visual Observations/Photos (if available)
General Inspection Procedures:
Condition:
Hazard:
Friable:
Analysis/Results:
Summary of ACMs:
Summary of LBPs:
Conclusions:
Recommendations:
PLM Analysis and CoC: Page 4 through 10
END OF REPORT
Project ID
Project Name
Year Constructed
Project Building
Historical Samplings
Room/Post Location
Inspector(s)
Requestor
Report Prepared By
Inspection Date
Results
Analysis
Friable
Condition
Classification