Waste Diversion Plan.xlsx

XLSX spreadsheet 20 KB Posted

Attached to
32214 Chavez Switchgear Replacement Albuquerque, NM Federal contract opportunity
Solicitation number
47PH0622R0018
Issued by
General Services Administration Public Buildings Service Region 7

About this file

This document contains a federal contract opportunity notice and related project file. The General Services Administration, Public Buildings Service is seeking a construction contractor to replace electrical switchgear at the Dennis Chavez Federal Building in Albuquerque, New Mexico for between $1 million to $5 million. The project includes design and replacement of the main 3000A 277/480V electrical gear in the basement, removing plaza drains above the switchgear room, adding a new tapered insulation and waterproofing system, and demolishing and replacing the existing switchgear egress door and sink. The contractor must be a general construction firm under NAICS 238210 with a size standard of $16.5 million. The project is anticipated to take 210 calendar days from notice to proceed and will require work in an occupied federal courthouse with minimal disruptions. This is a 100% service-disabled veteran-owned small business set-aside solicitation, with the proposal due date of June 24, 2022 and a pre-proposal conference scheduled for June 6, 2022. Prospective contractors must register in the System for Award Management and monitor the solicitation website for any amendments.

View the file

Other files for this federal contract opportunity

Other files attached to 32214 Chavez Switchgear Replacement Albuquerque, NM, newest first.
File Type Posted
SF30 Amendment 05.pdf PDF
SF30 Amendment 04.pdf PDF
SF30 Amendment 03.pdf PDF
SF30 Amendment 02.pdf PDF
SF30 Amendment 01.pdf PDF
Drawing 8.pdf PDF
Drawing 3.pdf PDF
GSA527.pdf PDF
Project Manual 101920.pdf PDF
Drawing 12.pdf PDF
Past Performance Questionnaire.pdf PDF
Drawing 11.pdf PDF
Drawing 10.pdf PDF
Drawing 9.pdf PDF
Drawing 2.pdf PDF
SF1442 47PH0622R0018.pdf PDF
Drawing 13.pdf PDF
Drawing 7.pdf PDF
Drawing 6.pdf PDF
Drawing 5.pdf PDF
Drawing 4.pdf PDF
Drawing 1.pdf PDF
Bid Schedule Template.xlsx XLSX spreadsheet
Vendor Fitness Determination Training Manual.pdf PDF
Show all 24

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Waste Diversion Plan

: +christopher.clever@gsa.gov +walter.tersch@gsa.gov

(For consideration as an alternate). Anticipated sections match Actual to the right for 1:1 comparison.

-Jake Begnaud - WPIDBB Fine with either, will defer to +walter.tersch@gsa.gov Seems like it only boils down to estimating method or not.

-Christopher Clever - PCBL That's correct.

-Jake Begnaud - WPIDBBProject Waste Management PlanSubmittal Type:Waste Diversion Plan (Anticipated):Waste Diversion Report (Final) :
The general info in these gray cells replicates onto the Report tabs.
Project Name:Chavez Switchgear ReplacementECC (estimated construction cost):Project Manager:SethSutherlandePM/ePMX Project # :32214
Project Short Description:PM email or phone:seth.sutherland@gsa.govgBUILD Project # :NA
Building Number:Service Center / Field Office:Budget Activity:(list all applicable)RWA # :NA

Anticipated Waste Diversion Plan To be filled out and submitted Pre-Construction, with final Construction Documents (PM or contractor populates this pink section) Actual Waste Diversion Report To be submitted during Project Close-Out (Reports tab figures auto-populate this green section)

Material*
(see weight conversion factors below)Diversion MethodTarget Diversion Rate for each material, by weight
(Change to actual target(s) as needed)Diverted (lbs)Landfilled (lbs)Total C&D material weight (Diverted + Landfilled) (lbs)Diversion

Rate

Reuse*Recycle or CompostDonation
Asphalt50%000n/a
Brick, Masonry, and Tile50%000n/a
Cardboard50%000n/a
Carpet, including Padding50%000n/a
Ceiling tile50%000n/a
Concrete50%000n/a
Drywall/ sheetrock (unpainted)50%000n/a
Metals50%000n/a
Painted wood, drywall, or plywood50%000n/a
Reusable items50%000n/a
Roofing50%000n/a
Soil, Rock, Land Clearing Debris50%000n/a
Wood (unpainted)50%000n/a
Other: ____________________50%000n/a
Other: ____________________50%000n/a
Other: ____________________50%000n/a
Total**:000n/a
Reuse is encouraged. Please list any items such as cabinets, doors, shelves, bricks, framing lumber, siding, fill material, misc. millwork, etc. planned for reuse.
ItemReuse OnsiteReuse OffsiteOff-Site Recipient or Salvage/ Deconstruction Company
Volume-to-Weight Conversion Factor Reference Table
If a hauler reports materials by volume, this table enables conversion to weight, for reporting actual diversion and disposal.
Asphalt paving: 1 cubic yard = 773 lbsDirt or sand: 1 cubic yard = 929 lbs
Asphalt or composite roof shingles: 1 cubic yard = 731 lbsFiberglass insulation, loose: 1 cubic yard = 17 lbs
Brick, laid flat: 1 flat square foot = 20 lbsMixed (composite) C&D material: 1 cubic yard = 417 lbs
Brick, loose: 1 cubic yard = 3,200 lbs. (1 cubic foot = 120 lbs)Sheetrock (drywall), loose: 1 cubic yard = 393.5 lbs
Ceramic tile, scrap, loose: 1 cubic yard = 1,214 lbsRock, crushed: 1 cubic yard = 2,570 lbs
Concrete: 1 cubic yard = 860 lbsWood: 1 cubic yard = 169 lbs
*Only non-hazardous materials need to be included in this document. C&D mandates governing GSA exclude hazardous materials such as asbestos or lead-containing paint.
**At substantial completion, the final number of (a) diverted tons, and (b) total non-hazardous C&D material tons must be reported via the ePMXpress Project Detail tab. ePMXpress powers GSA's tracking metrics.

mailto:seth.sutherland@gsa.gov

File details come from the government source that posted it. Updated .