B08 - PWS Attachment IV - Hydraulic Elevator Test.docx

DOCX document 81 KB Posted

Attached to
Elevator Repair and Maintenance Support Services
Solicitation number
W91RUS-27-R-A002
Issued by

About this file

This is a Performance Work Statement (PWS) attachment that establishes the periodic inspection and testing requirements for hydraulic elevators at Fort Huachuca under the elevator repair and maintenance support services contract. The document provides a comprehensive checklist for three levels of inspections: bi-annual inspections covering static and relief pressure tests and safety tests per ASME Section 1005.1 and 1002.1; annual inspections addressing relief valve settings, system pressure, hydraulic cylinders, pressure piping, terminal stopping devices, governors, over-speed switches, seals, safeties, oil buffers, firefighter emergency operation, standby power operation, door systems, emergency terminal speed reduction devices, low oil protection, flexible hose assemblies, and pressure switches per ASME Section 8.11.3.2; and five-year inspections covering car and counterweight safeties, governors, oil buffers, coated ropes, wire rope fastenings, plunger grippers, and over-speed valves per ASME Section 8.11.3.4.

The PWS requires all inspections and tests to be performed in strict compliance with ASME A17.1 standards. The document includes fields for documenting building information, unit identification, test results (pass/fail/not applicable), performing contractor details, mechanic name, and service date, establishing clear documentation and accountability requirements for the maintenance contractor executing elevator inspection and repair services at the Fort Huachuca installation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Fort Huachuca, Directorate of Public Works Periodic tests of Hydraulic Elevators Check List

Test Performed: Bi-Annual ☐ Annual ☐ Five (5) Year ☐

Building & Unit Information

Building Name
Owner/Building Management Name
Building Address
Unit Identification / Unit PIN
BI-ANNUAL INSPECTIONS
ASME Section
Pass
Fail
N/A
Static and relief pressure test
1005.1
Safety test
1002.1
ANNUAL INSPECTIONS
ASME Section
Pass
Fail
N/A
Relief Valve Setting and System Pressure Test
8.11.3.2.1
Hydraulic Cylinders and Pressure Piping
8.11.3.2.2
Normal Terminal Stopping Devices
8.11.3.2.3(a)
Governors, Over speed Switch, and Seals
8.11.3.2.3(b)
Safeties
8.11.3.2.3(c)
Oil Buffers
8.11.3.2.3(d)
Firefighter’s Emergency Operation
8.11.3.2.3(e)
Standby Power Operation
8.11.3.2.3(f)
Power Operations of Door System
8.11.3.2.3(g)
Emergency Terminal Speed Reducing Devices
8.11.3.2.3(h)
Low Oil Protection Operation
8.11.3.2.3(i)
Flexible Hose and Fitting Assemblies
8.11.3.2.4
Pressure Switch
8.11.3.2.5
FIVE (5) YEAR INSPECTION
ASME Section
Pass
Fail
N/A
Car and Counterweight Safeties
8.11.3.4.1
Governors
8.11.3.4.1
Oil Buffers
8.11.3.4.1
Coated Ropes
8.11.3.4.2
Wire Rope Fastenings
8.11.3.4.3
Plunger Gripper
8.11.3.4.4
Over speed Valves
8.11.3.4.5

The Above Tests Were Performed In Compliance With ASME A17.1

Firm Performing Test/Service
Elevator Contractor Number
Firm Address
Firm City/State/Zip
Name of Mechanic Performing Test/Service
Date of Test/Service