SCOPE OF WORK & GENERAL NOTES
EXST/REMOVAL GROUND FLOOR PLAN
NEW GROUND FLOOR PLAN
ROOF PLAN
ELEVATIONS-1
ELEVATIONS-2
SECTIONS
ENLARGED FLOOR PLAN
ENLARGED FLOOR PLAN AND INTERIOR ELEVATIONS - 1
ENLARGED FLOOR PLAN AND INTERIOR ELEVATIONS - 2
EXTERIOR WALL SECTIONS
INTERIOR WALL SECTION
ROOF DETAILS
CABINET DETAILS
MISC DETAILS - 1
MISC DETAILS - 2
MISC DETAILS - 3
MISC DETAILS - 4
MISC DETAILS - 5
INTERIOR, EXTERIOR FINISH SCHEDULE & FINISH SCHEDULE NOTES
MATERIAL & COLOR SCHEDULE
DOOR / WINDOW SCHEDULE, ELEVATIONS AND DETAIL
HARDWARE SCHEDULE & DOOR / WINDOW NOTE
SIGNAGE PLAN, SCHEDULE & DETAILS
SCHEDULE OF DRAWINGS
RING NO. REF. NO.REVISION STATUSDWG. NO. SHT. NO.REF. NO.
T - 1
RING NO.
CIVIL
C - 1
M - 1
M - 2
M - 3
MECHANICAL
A - 1
A - 2
A - 3
ARCHITECTURAL
DESCRIPTION OF DRAWINGS DWG. NO. SHT. NO. DESCRIPTION OF DRAWINGS REVISION STATUS
T-1
A - 4
A - 5
A - 6
A - 7
A - 8
A - 9
M - 4
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A - 10
A - 11
A - 12
A - 13
A - 14
A - 15
A - 16
A - 17
A - 18
A - 19C - 2
C - 3
C - 4
C - 5
T - 2
TITLE SHEET-1
TITLE SHEET-2
TITLE SHEET - 1
M - 5
M - 6
M - 7
M - 8
M - 9
M - 10
M - 11
M - 12
A - 20
A - 21
S - 1
S - 2
S - 3
S - 4
S - 5
STRUCTURE
C - 6
C - 7
C - 8
A - 22
A - 23
A - 24
S - 6
S - 7
REPAIR BUILDING
REPAIR BUILDING
SEWER M/H
MISC. DETAILS - 3
MISC. DETAILS - 2
MISC. DETAILS - 1
RAMP DETAIL
SITE LAYOUT PLAN AND SCOPE OF WORK
REMOVAL PLAN
GENERAL NOTES
DETAILS
BEAM, COLUMN, WALL & FOUNDATION SCHEDULE
CROSS SECTIONS
ROOF FRAMING PLAN
FOUNDATION/NEW GROUND FLOOR PLAN
EXISTING/REMOVAL FLOOR PLAN
GENERAL NOTES, DESIGN DATA & TYPICAL DETAILS
MECH. DETAILS - 3
MECH. DETAILS - 2
MECH. DETAILS - 1
MECH. CONTROL DIAGRAMS
NEW SEWER & VENT PIPING ENLARGED PARTIAL PLAN
NEW DOMESTIC WATER PIPING ENLARGED PARTIAL PLAN
NEW H.V.A.C ENLARGED PLAN
NEW H.V.A.C PIPING ENLARGED PLAN
EQUIPMENT SCHEDULES - 1
EQUIPMENT SCHEDULES – 1
GENERAL NOTES & SCOPE OF WORK
LEGEND & ABBREVIATION
ELECTRICAL
E - 1
E - 2
E - 3
E - 4
E - 5
E - 6
E - 7
E - 8 NEW POWER PLAN
LIGHTING FIXTURE SCHEDULE
LIGHTING FIXTURE DETAILS
NEW LIGHTING PLAN
EXIST/NEW EXTERIOR TELECOMMUNICATION LINE DISTRIBUITION PLAN-2
EXIST/NEW EXTERIOR TELECOMMUNICATION LINE DISTRIBUITION PLAN-1
EXIST/NEW EXTERIOR POWER LINE DISTRIBUTION PLAN
LEGEND, GENERAL NOTES AND SCOPE OF WORKS
ELECTRICAL
E - 9
E - 10
E - 11
E - 12
E - 13
SCHEDULE OF DRAWINGS
RING NO. REF. NO.REVISION STATUSDWG. NO. SHT. NO.REF. NO.RING NO. DESCRIPTION OF DRAWINGS DWG. NO. SHT. NO. DESCRIPTION OF DRAWINGS REVISION STATUS
T-2
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
TITLE SHEET - 2
REPAIR BUILDING
REPAIR BUILDING
E - 14
E - 15
E - 16
E - 17
E - 18 NEW CATV DIAGRAM
NEW CATV PLAN
NEW LAN/TEL SYSTEM DIAGRAM
NEW LAN/TEL PLAN
NEW FIRE ALARM/MASS NOTIFICATION SYSTEM DIAGRAM
NEW FIRE ALARM AND MASS NOTIFICATION SYSTEM PLAN
NEW PANELBOARD "C" & "MDP" LOAD SCHEDULE
NEW PANELBOARD "P1", "P2" & "M" LOAD SCHEDULE
EXIST/NEW POWER ONE-LINE DIAGRAM
NEW POWER/CONTROL PLAN FOR MECHANICAL SYSTEM
WALL
STIRRUP OR TIE
PRECAST CONCRETE COVER, REFER TO ACI-318 CHAPTER 7.
3. PROTECTIVE COVER SHOWN IS FOR CAST-IN-PLACE CONCRETE ONLY. FOR
2. THICKER PROTECTIVE COVER INDICATED IN SPECIFIC DETAILS SHALL GOVERN.
1. PROTECTIVE COVER SHOWN IS MINIMUM PERMITTED
CONCRETE CAST
AGAINST EARTH
BEYOND
CONCRETE EXPOSED TO
EARTH OR WEATHER
NOTE
EXTERIOR
MAIN OR TEMPERATURE
EARTH/CONC
BAR (TYP)
STIRRUP OR
TIE
EARTH
FACE
SURFACE
TEMPERATURE
BAR (TYP)
STIRRUP OR
MAIN OR
FORMED CONC
TIE
MAIN OR
BAR (TYP)
TEMPERATURE
BEAM
BARSMAIN BAR
CONCRETE NOT EXPOSED TO
EARTH OR WEATHER
COLUMN STIRRUP
20 CLR
BEAM
20 CLR
MAIN
40 CLR
SLAB
JOINTS SHALL BE LOCATED AT THE MIDDLE 1/6 OF THE SLAB SPAN IN EITHER
Fy = 240 MPa
Fu = 400 MPa
Fu = 490 MPa
Fu = 1000 MPa fy = 400 MPa fy = 448 MPa f'c = 18 MPa
3. METAL YIELD STRENGTHS (Fy) OR TENSILE STRENGTHS (Fu) :
f'c = 24 MPa
- MACHINE/ANCHOR BOLTS
- HIGH STRENGTH BOLTS (F10T OR A325)
- WELDING ELECTRODES (E70xx)
- WELDED WIRE FABRIC
- THRUST BLOCKS AND OTHER PLAIN CONCRETE
- ALL CONCRETE UNLESS NOTED OTHERWISE
C. MATERIAL STRENGTHS :
- REINFORCING BARS (SD40 OR GRADE 60)
- STRUCTURAL STEEL (SS400 OR A36)
4,800 Pa
960 Pa
960 Pa
2,400 Pa
TO CLEAN AND ROUGH STANDARDS.
DIRECTION. ALL REINFORCING BARS SHALL BE CONTINUOUS THROUGH CONSTRUCTION
JOINTS AND CONCRETE JOINT FACES SHALL BE KEYED OR INTENTIONALLY ROUGHENED
- STORAGE, MECH, ELEC RM
DESIGN DATA
A. DESIGN LOADS :
2. FLOOR LIVE
- GROUND SNOW
- LIVE
- OFFICE
1. ROOF
AND SHALL BE MODIFIED TO SUIT THE SELECTED EQUIPMENT.
PERIMETER FELT JOINTS. UNDER NO CIRCUMSTANCES SHALL SUCH JOINTS BE
D. CONSTRUCTION JOINTS ARE PERMITTED IN STRUCTURAL SLABS ON GRADE IF REQUIRED
BY CONCRETE PLACEMENT AND FINISHING LIMITATIONS. WHEN REQUIRED, CONSTRUCTION
CLEAN AND ROUGH JOINT SHALL REFER TO A CONCRETE TO CONCRETE CONTACT
SURFACE WHICH IS CLEAN AND FREE OF LAITANCE AND INTENTIONALLY ROUGHENED
1. DIMENSIONS, LOCATIONS, AND SIZES OF EQUIPMENT SUPPORTS, PADS, AND ROOF
OR WALL OPENINGS SHOWN ON THESE DRAWINGS ARE FOR INFORMATION ONLY
2. ANCHOR BOLTS SHALL BE SIZED AND LOCATED AS REQUIRED BY THE EQUIPMENT
A MINIMUM DISTANCE OF 150mm SHALL BE MAINTAINED FROM CENTER OF ANCHOR
3. SEE MECHANICAL DRAWINGS FOR ADDITIONAL PIPES, RISERS, VENTS, AND DUCTS
4. CONCRETE PLACED OVER PIPING SHALL BE POURED ONLY AFTER THE PIPING HAS
C. STRUCTURAL SLABS DO NOT REQUIRE CONTRACTION JOINTS, EXPANSIONS JOINTS, OR
TO AN AMPLITUDE OF 6mm (MINIMUM). JOINT SHALL BE CLEANED WITH WATER BLAST
MANUFACTURER'S SHOP DRAWINGS.
BOLT TO EDGE OF EQUIPMENT PAD.
WHICH PENETRATE THE ROOF, FLOOR OR WALL.
BEEN INSPECTED, TESTED AND APPROVED.
PERMITTED IN STRUCTURAL SLABS ON GRADE.
B. MECHANICAL EQUIPMENT
GENERAL NOTES
A. CONCRETE CLEAN AND ROUGH JOINT(CRJ)
CHIPPING HAMMER, OR OTHER SUITABLE MEANS.
1. CONCRETE MINIMUM COMPRESSIVE STRENGTH (f'c) :
- MINIMUM STANDARD
5. ANTITERRORISM (UFC 4-010-01, 9 FEB 2012)
M
IN
SLEEVE
M
IN
SLEEVE
BEAM
MINMIN
SECTION "A-A"
SLEEVE
"A"
GRADE BEAM
FOOTING OR
STEM WALL
"A"
PARALLEL PIPE PERPENDICULAR PIPE
M
IN
MIN
BELOW THIS PLANE
EMBEDMENT PERMITTED
NO PIPE OR CONDUIT
FOOTING OR GRADE
NOT TO SCALE
STANDARD HOOK FOR MAIN BARS, STIRRUPS & TIES
NOT TO SCALE
CONCRETE PROTECTION FOR REINF BARS
NOT TO SCALE
PIPE OR CONDUIT AT FOUNDATION
NOTE : SEE PLUMBING DRAWINGS
FOR SLEEVE DETAIL
STANDING SEAM METAL ROOFINGSSMR
RIM JOISTRJ
EAVE STRUTES
BOPC BOTTOM OF PILE CAP
CONC CONCRETE
CONSTRUCTION JOINTCNJ
CONTINUOUS OR CONTINUECONN
CWB CAPILLARY WATER BARRIER
HIGH STRENGTH BOLT
IJ ISOLATION JOINT
DET DETAIL
DIAMETERDIA
DIM DIMENSION
DN DOWN
DWG DRAWING
DWGS DRAWINGS
EACH FACEEF
EACHEA
EL ELEVATION
EQUIP EQUIPMENT
EW EACH WAY
EJ EXPANSION JOINT
EXP JT EXPANSION JOINT
EXST EXISTING
FL FLOOR
FNSH FINISH
FOOTFT
HGT HEIGHT
GRADE BEAMGB
GALVANIZEDGALV
HORIZ HORIZONTAL
HSB
JOINTJT
ELEC ELECTRICAL
EQ EQUAL
INDICATOR PILEIP
WWF
VARIABLEVAR
WITHW/
VERT VERTICAL
TRANSVERSALTRANS
TYP TYPICAL
THICKENED SLABTS
TOC TOP OF CONCRETE
THROUGHTHRU
TOP BART BAR
THK THICKNESS
BOTTOM BARB BAR
BOTTOM MOST BARBM BAR
STRUCTURALSTRL
STL STEEL
STD STANDARD
SQ SQUARE
SPEC(S) SPECIFICATION(S)
SIMILARSIM
SCHEDULESCHED
STRUC STRUCTURAL
RO ROUGH OPENING
ROOMRM
RFG ROOFING
REQUIREDREQD
REPL REPLACE OR REPLACEMENT
REINFORCED OR REINFORCEMENTREINF
RC REINFORCED CONCRETE
RADIUSRAD
PROJECTPROJ
PANELPNL
PC PILE CAP
PEDESTALPED
PEJ PRE-MOLDED EXPANSION JOINT
OPPOSITEOPP
OPNG OPENING
ON CENTEROC
NTS NOT TO SCALE
LONGITUDINALLONGIT
NUMBERNO
NOT IN CONTRACTNIC
NON FROST SUSCEPTIBLE MATERIALNFSM
NA NOT APPLICABLE
MISCELLANEOUSMISC
MIN MINIMUM
MANUFACTUREMFR
MEZZANINEMEZZ
MACHINE BOLTMB
METALMET
MECH MECHANICAL
MIDDLEMID
MAX MAXIMUM
MATERIALMATL
MAINT MAINTENANCE
LG LENGTH
COLUMNCOL
CONCRETE MASONRY UNITCMU
CLEARANCECLR
CRACK CONTROL JOINTCLJ
CJ CONTROL JOINT
CENTER LINECL
BOT BOTTOM
BEAMBM
BKS BARRACKS
BLDG BUILDING
ARCHITECTURALARCH
ANCHOR BOLTAB
WELDED WIRE FABRIC
AUTOMATIC WELDING STUDAWS
ABBREVIATIONS
QTY QUANTITY
2. CONCRETE MASONRY UNITS(CMU)
- CMU STRENGTH
- GROUT STRENGTH
f'm = 9.3 MPa f'c = 14 MPa
- MORTAR TYPE "S"
SIZE
BAR
DIMENSION
DETAILING
D E
T A
IL
IN
G
D
IM
E N
S
IO
N
D E
T A
IL
IN
G
D
IM
E N
S
IO
N
DETAILING
A or G
D (mm)SIZE
BAR
140HD22
HD13
HD19
HD16
HD10
(mm)
HOOKS
(mm) A or G
STIRRUP & TIE HOOKS
D=4d FOR HD10 ~ HD16 BARS
D=6d FOR HD10 ~ HD25 BARS
D=8d FOR HD29, HD32 BARS
MAIN BAR HOOKS
HD19
HD22
HD16
HD13
HD29
HD32
HD25
A
B
(mm)
HD16
HD10
HD13
D
D=6d FOR HD19, HD22 BARS
SEISMIC STIRRUP/TIE HOOKS
D=4d FOR HD10 ~ HD16 BARS
APPROX.
A or G (mm)
H(mm)
C
L BEAM
(mm)
DIMENSION
SIZE
HD10
A or G
(mm)
BAR
D
(mm) J
L BEAM
A or G (mm)
HOOKS
c c
(UFC 4-023-03, 27 JAN 2010)
D E
T A
IL
IN
G
D
IM
E N
S
IO
N
M
IN
APPROX.
H(mm)
1220 mm
Kzt = 1.00
Kz = 0.9
I = 1.00
V = 59.4 M/SEC
CLASS D
S1=0.07g, Ss=0.16g
150 kPa
- BASIC WIND SPEED
- IMPORTANCE FACTOR (CATEGORY II)
- EXPOSURE CATEGORY
- EXPOSURE COEFFICIENT
- TOPOGRAPHIC FACTOR
- MINIMUM DESIGN BEARING CAPACITY
- IMPORTANCE FACTOR
- FROST DEPTH
B. FOUNDATIONS :
1. DESIGN PARAMETERS
- SEISMICITY
- SOIL TYPE
4. SEISMIC (UFC 3-301-01)
- OCCUPANCY CATEGORY
C
3. WIND (UFC 3-301-01/IBC)
- DESIGN CATAGORY B
II
f'c = 30 MPa - SLAB ON GRADE
75 CLR.
C L
R
40 CLR.
H d
DdD D d
D J d
D dD D
6d
H d
40 CLR
40 CLR
20 CLR 20 CLR
230230
M A X .(6 d ,7 m m
A o r
G
MAX.(4d,60mm)
A or G d
A or G
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
FORCE PROTECTION
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
- 1
- 1
- 1
S-1
& TYPICAL DETAILS
GENERAL NOTES, DESIGN DATA
STRUCTURE
REPAIR BUILDING
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
FORCE PROTECTION
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
2000mm10005000
SCALE: 1:50
STRUCTURE
REPAIR BUILDING
S-2
SCALE:
2- 1/50
EXST/REMOVAL GROUND FLOOR PLAN
FLOOR PLAN
EXST / REMOVAL GROUND
11841
66601815000
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
FORCE PROTECTION
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
SCALE:
3- 2000mm10005000
SCALE: 1:50
-50
-5
-5
-5
-5
-50
-50
4000330033003300330033004000
24500
SCOPE OF WORK
REPAIR AND MAINTENANCE WORK
LEGEND
200THK CONC WALL
50 DEPRESSED SLAB
SEE
- 7
WF1
WF1
W F
W F
C L J
C L J
C L J
C L J
C L J
C L J
C L J
C L J
C L J
C L J
C L J
C L J
C L J
C L J
C L J
C L J
C L J
C L J
CLJ
CLJ CLJ
CLJ CLJ
CLJ
CLJ CLJ
CLJ
CLJ CLJ
CLJ
CLJ
FOUNDATION/NEW GROUND FLOOR PLAN
1/50
C L J
CF1 P1/SC2
CF1 P1/SC2
MEMBER SCHEDULE
: 400 x 400 CONC PEDESTAL
SC2
P1
WF1
CF1
: 1200Wx300D SPREAD FOOTING
: 800 x 800W x 300D COLUMN FDN
FOUNDATION SCHEDULE
: 200 x 200 x 6.0THK STL COLUMN
-50
-50
-5
-2
-250
250 DEPRESSED SLAB
CONSTRUCT 150THK CONC SLAB.
CONSTRUCT WALL W/ 200THK CONC WALL & FOUNDATION.
CONSTRUCT ROOF W/ STEEL COLUMN & BEAM.
SUBMIT STRUCTURE DESIGN ANALYSIS AND SHOP DRAWING FOR APPROVAL.
STRUCTURE
REPAIR BUILDING
S-3
FLOOR PLAN
FOUNDATION / NEW GROUND
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
FORCE PROTECTION
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MEMBER SCHEDULE
SC1
SG1
STR1 : H - 200x100x5.5x8 STL STRUT BEAM
LB1 : C-250x90x9x13 LEDGER BEAM
P : LC-200x75x25x4.0 PURLIN
RJ : LC-200x75x25x4.0 RIM JOIST
LEGEND
: MOMENT CONNECTION
: SHEAR CONNECTION
WG1 : 300W x 400D CONC BEAM
1 2
A
B
SCALE:
4- 1/50
2000mm10005000
SCALE: 1:50
ROOF FRAMING PLAN
L B
L B
L B
L B
R J
R J
R J
R J
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
STR1STR1 STR1 STR1 STR1 STR1 STR1
STR1STR1STR1STR1STR1STR1STR1
SC1 SC1 SC1 SC1 SC1 SC1
SC1SC1SC1SC1SC1SC1
STR1 STR1 STR1 STR1 STR1 STR1 STR1
S G
S G
S G
S G
S G
S G
3500350035003500350035003500
24500
STR1 STR1 STR1 STR1 STR1 STR1 STR1
STR1 STR1 STR1 STR1 STR1 STR1 STR1
: H - 250x250x9x14 STL COLUMN
: H - STL BEAM (BY ROOF MFR) - TYP
P
P
P
P 5
S G
SG2
SG2
RJ
RJ
R J
SC2
SC2
SG2 : H - 200x100x5.5x8 STL BEAM
SC2 : H - 200 x 200 x 6.0THK STL COLUMN
STRUCTURE
REPAIR BUILDING
S-4
ROOF FRAMING PLAN
TOP OF CONC
TOP OF STL
FL + 500 mm
PEDESTAL
400 x 400 CONC
SG2
PURLIN (P)
LC-200x75x25x4.0
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
FORCE PROTECTION
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
1200 1200 1200 1200
65015100650
75507550
PURLIN (P)
LC-200x75x25x4.0
STR1
STANDING SEAM METAL
ROOFING (TYP.)
SC1
SG1
WG1
150THK SLAB ON GRADE
W/ #8-150x150 WWF 10mmTHK PEJ
W/ SEALANT
22DIA. ROD BAR
SEE. DWG
6-
BACKFILL W/
SATISFACTORY MATERIAL
WF1
200THK
WALL (W1)
WF1 WF1 WF1
50023500500
3000350035003500350035003000
V A
R
1200 1200 1200 1200 800
WF1 WF1 WF1 WF1
STL COLUMN
P-200 x 200 x 6.0THK
SEE. DWG
6-
10mmTHK PEJ
W/ SEALANT
150THK SLAB ON GRADE
W/ #8-150x150 WWF
VAPOR BARRIER
150THK CWB
VAPOR BARRIER
150THK CWB
STR1
SG1 SG1
STR1
SG1
STR1
SG1
STR1
SG1
STR1
SG1
STR1 STR1
PURLIN (P)
LC-200x75x25x4.0
WG1 WG1
200THK
WALL (W1)
A B
SCALE: 1/50
CROSS SECTION-1
SCALE: 1/50
CROSS SECTION-2
2000mm10005000
SCALE: 1:50
5-
5-
GL
FL + 500 mm
GL
STRUCTURE
REPAIR BUILDING
S-5
CROSS SECTIONS
SCALE:
PEDESTAL SCHEDULE
1/20
COLUMN SCHEDULE
P1 f'c = 24 MPa fy = 400 MPa
SCALE:
WALL SCHEDULE
1/20
WALL SCHEDULE
200 THK WALL (W1)
f'c = 24 MPa fy = 400 MPa
HD16 @300
VERT BARS
HD16 @300
HORIZ BARS
SCALE:
BEAM SCHEDULE
1/20
BEAM SCHEDULE
WG1
f'c = 24 MPa fy = 400 MPa
4 - HD22
TOP BARS
4 - HD22
BOT BARS
HD13 @200
STIRRUP
NOT TO SCALE
WALL FOUNDATION SCHEDULE
WF1
MARK REINFORCING
HD19 @200
'T' BAR 'L' BARW D
1200 300
DIMENSION
H
1550 6 - HD16
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
FORCE PROTECTION
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
C
IV
IL
GROUND FL
FELT JOINT
W/ SEALANT
10THK PERIMETER
VAPOR BARRIER
150THK CWB
'L' BAR
'T' BAR
W
D
C L
R
V A
R
S E
E
H
STRUCTURE
SCHEDULE
BEAM, COLUMN, WALL & FOUNDATION
5-
5-
5-
5-
S-6
NOT TO SCALE
5-
8-HD16
VERT BARS
HD10 @200
TIE BAR
HD16@300 O.C.,
E.W. & E.F.
POUR JOINT
HD16@300 O.C.,
E.W. & E.F.
DETAIL
CONC WALL
PEJ : PERIMERTER FELT EXPANSION JOINT
10THK PEJ
W/SEALANT
NOTE FOR SLAB ON GRADE.
WWF
DETAIL.
ALL CONTROL JOINT IN SLAB SHALL BE PER FOLLOWING
IN EACH DIRECTION UNLESS OTHERWISE NOTED
1. PROVIDE CONTROL JOINT @6000 MM (MAX)
150THK CWB
VAPOR BARRIER
FORMED JOINT
3.2mm x t/4 SAWED OR
MW10(#8)-100X100
40 CLR
SCALE:
DETAIL
1/20
150THK CWB
WWF
MW10(#8)-150X150
SCALE: 1/20
200THK CONC
WALL
3-M16x120LG
WEDGE A.B.
VAPOR BARRIER
150THK CWB
SCALE:
DEPRESSED SLAB
1/20
150x150 WWF
HD13
NFSM.
40CLR
W/ SEALANT
MW10(#8)-
10 PEJ
SCALE:
CONC STOOP DETAIL
1/20
40 CLR
OR 900
A
DIA22 ROD
BRACE W/
TURNBUCKLE
A
W/ TURNBUCKLE
DIA22 ROD BRACE
90x75x9THK
STEEL PL
SCALE:
HORIZ. BRACE DETAIL
1/30
9THK STIFFNER
SLOT HOLES
25DIAx50LG.
WG
ROOF BEAM
M20 A.B.(350LG)
20THK BEDDING
MORTAR
SB1, SB2
CUT FORM
SCALE:
ROOF DETAIL
1/10
H194x150x6x9(SC1)
H200x200x8x12(SC2)
SB2
SB4
SB2
A-A' SECTION
SB2
LEDGER BEAM(LG1)
C-250x90x9x13
W/ M16x110LG WEDGE
ANCHOR @600 O.C.
SCALE:
CONNECTION DETAIL
1/10
W/ 4-M16x120LG
250x250x9 PL
AWS
AWS PLATE
SCALE:
CONNECTION DETAIL
1/10
PURLIN
PURLIN SECTION
LC-200x75x25x4
L150x90x9x80
W/ 2-M12 MB
PURLIN
L75x75x6x100LG
W/ 2-M12 MB
RIM JOIST
RIM JOIST
PURLIN
L150x90x9x80LG
W/ 2-M12 MB
ROOF BEAM
TYP. PART
6THK PLATE
W/ 2-M12 MB
L150x90x9THK
BENT PLATE
LC-200x75x25x4
LC-200x75x25x4
LC-200x75x25x4
SCALE:
PURLIN CONNECTION DETAIL
1/10
ROOF BEAM
L150x90x9x165LG
W/ 2x2-M12 MB
SPLICE PART
LC-200x75x25x4
PURLIN
ROOF BEAM
9THK PLATE
W/2-M20 HSB
SCALE:
SHEAR CONNECTION DETAIL
1/10
W/ 2-M16x120LG
250x250x9 PL
AWS
AWS PLATE
HSB
9THK PL W/ 2-M20
200THK CONC WALL
SCALE:
CONNECTION DETAIL
1/10
SCALE:
MECH PAD DETAIL
1/20
VAPOR BARRIER
150THK CWB
W/ SEALANT
AT ALL EDGES
20mm CHAMFER
10THK
PERIMETER
FELT JOINT
SIZE & LOCATION
CHEMICAL ANCHOR BOLT
AS REQ'D BY EQUIPMENT
@300 O.C. E.W. & E.F.
HD13
50 50
SEE PLAN
4040 10
1504040
50 50
50 50
SEE PLAN
150MIN.
C L
R
150MIN.
12 THK BASE PL W/
LEDGER BEAM
C-250x90x9x13
LEDGER BEAM DETAIL
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
FORCE PROTECTION
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
- 6
- 6 - 6 - 6 - 6
- 6
- 6
- 6- 6- 6- 6
- 6
1-16DIAx100LG WEDGE ANCHOR
TOP OF
CONC WALL
20THK BEDDING MORTAR
PURLIN SECTION(@CONC)
L150x90x9x80LG
W/ 2-M12 MB
PURLIN
LC-200x75x25x4
STL STRUT BEAM(STR1)
H - 200x100x5.5x8
STRUCTURE
DETAILS
S-7