Correct Atta 1-3 Drawings_Non-WorkPlanOMA_ARCH.pdf
PDF 4 MB Posted
- Solicitation number
- W91QVN23R0027
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
A-1
GENERAL NOTES
NOT IN THIS CONTRACT.
ALL FURNITURE WHICH IS SHOWN ON FLOOR PLANS AND DETAIL DRAWINGS IS GFGI AND
MANUFACTURES INDICATED.
PURPOSES ONLY. AND NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE
COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR BIDDING IDENTIFICATION 1.
ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER REPRESENTATIVE (COR).
CAUSED BY THIS PROJECT AND SHALL REPAIR THE DAMAGES TO MATCH UP TO
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES MADE TO EXISTING AREAS
FOR APPROVAL.
CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITION AND SUBMITED TO COR
CONDITION. IN THAT CASE, SHOP DRAWINGS SHALL BE PREPARED AT THE SITE BY THE
SOME DETAILS SHOWN ON CONTRACT DRAWINGS MAY NOT COINCIDE WITH THE FIELD
8.
FOR APPROVAL.
CONTRACTOR SHALL SUBMIT MANUFACTURER'S INSTALLATION SHOP DRAWINGS TO COR
2.
3.
4.
5.
6.
7.
CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER
IF THERE ARE ANY CONFLICTS WITHIN THE CONTRACT DOCUMENT. THE GENERAL
AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.
THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION
OF THE LOAD BEARING WALLS TO PREVENT COLLAPSE OF THE STRUCTURE
APPROPRIATE TEMPORARY SUPPORTS SHALL BE CONSTRUCTED PRIOR TO DEMOLITION
9.
10.
11.
12.
13.
14.
15.
BE AS A PART OF THE CONTRACT DOCUMENT OF THIS PROJECT.
STANDARD DETAIL DRAWINGS FOR O&MA PROJECT, KOREA, DATED OCTOBER 1, 2003 SHALL
NUMBERS ARE FROM TM-5-807-7 AND FEDERAL STANDARD NO. 595b, COLORS.
COLOR OF MATERIALS & PAINTS SHALL BE SELECTED BY USING AGENCY AND COLOR
DETAILS AND GET APPROVAL FROM COR. BEFORE FABRICATION AND INSTALLATION.
CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL DOOR/WINDOW
SPECIFICATION 15181.
ITEMS REQUIRING MAINTENANCE/OPERATION IAW THE SECTION 3.1.14, OMA STD
PROVIDE ACCESS DOORS FOR ALL CONCEALED VALVES, VENTS, CONTROLS AND OTHER
16.
WITHOUT ADDITIONAL COST TO THE GOVERNMENT.
HEATING, EQUIPMENT, ETC), ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM
REQUIRED FOR THE INSTALLATION AND/OR REPLACEMENT OF MECHANICAL (PLUMBING,
OBSTRUCTED ITEMS, CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING WHERE
THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL/REINSTALLATION OF ANY
OFFICE, DPW. PER DIRECTION FROM COR
SALVAGE OR SERVICEABLE MATERIALS SHALL BE RETURNED TO SUPPLY OR STORAGE
FROM THE MANUFACTURE SHOWING THE PRODUCT IS LEAD FREE.
A CERTIFICATE OR MATERIAL SAFETY DATA SHEET (MSDS), WRITTEN IN ENGLISH,
SOLIDS) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR SHALL PROVIDE
COATINGS WITH LESS THAN 0.05 PERCENT LEAD BY WEIGHT OF THE NON-VOLATILE
THE CONTRACTOR IS REQUIRED TO USE "LEAD FREE" COATINGS (LIQUID PAINTS OR
WALL : 2.290 SM. DEG K/W
ROOF : 4.215 SM. DEG K/W
R-VALUE for INSULATION :
SCOPE OF WORK (ARCHITECTURAL WORK)
1. FLOOR WORK
1.1
1.2
1.3
1.4
MEMBRANE, MORTAR BED AS SHOWN ON FLOOR PLANS, SECTION AND DETAILS DRAWINGS.
REPLACE DETERIORATED EXISTING FCT WITH NEW INCLUDING CEMENT BOND COAT, WATERPROOF
AND INTERIOR FINISH SCHEDULE.
APPLY EPOXY COATING WITH NON SLIP GRITS ON EXISTING FLOORS AS SHOWN ON FLOOR PLAN
PROVIDE LEVELING CONCRETE FOR EXISTING CONCRETE SLAB IF NEEDED.
HIGH SPOTS, PAINTING, AND UNEVEN SURFACE SHALL HAVE BEEN CORRECTED FOR NEW FLOORING.
TRUE, LEVEL PLANE WITH ALL DEFECTS SUCH AS ROUGH OR SCALING CONCRETE, LOW SPOTS,
FLOOR PLAN & INTERIOR FINISH SCHEDULE. THE EXISTING CONCRETE FLOORING SHALL BE SMOOTH, REPLACE DETERIORATED EXISTING FLOOR TILE WITH NEW PVCT INCLUDING VCB AS SHOWN ON NEW
2. INTERIOR & EXTERIOR WALL WORK
2.1
2.2
2.3
2.4
2.5
INTERIOR FINISH SCHEDULE.
PAINT ALL EXISTING INTERIOR WALLS INCLUDING AS SHOWN ON FLOOR PLAN, DETAIL DRAWINGS
ON FLOOR PLANS AND SECTIONS.
WATERPROOF MEMBRANE, PLASTERING W/METAL LATH AND WATERPROOF GWB AS SHOWN
REPLACE DETERIORATED EXISTING GCWT WITH NEW INCLUDING CEMENT BOND COATS,
AND DETAIL DRAWINGS.
REPLACE EXST EXTERIOR WALLS WITH NEW EIFS AS SHOWN ON FLOOR PLAN, ELEVATIONS, SECTIONS, 3.4
3.2
3.3
3.1
3. INTERIOR & EXTERIOR CEILING/ROOF WORK
ON FLOOR PLANS AND FINISH SCHEDULE.
WATER RESISTANT OR 'X' TYPE) CEILING INCLUDING CEILING SUSPENSION SYSTEM AS SHOWN
REPLACE DETERIORATED EXISTING CEILING WITH NEW GYPSUM WALL BOARD (GWB, NORMAL,
SECTION.
PAINT ON ALL INTERIOR CEILING SURFACES AS SHOWN ON INTERIOR FINISH SCHEDULE AND
METAL SUSPENSION SYSTEMS AS SHOWN ON FLOOR PLANS AND INTERIOR FINISH SCHEDULE.
REPLACE DETERIORATED EXISTING CEILING WITH NEW ACOUSTICAL CEILING TILES INCLUDING
FINISH SCHEDULE.
APPLY SKIM COAT PLASTER ON CONCRETE WALLS AS SHOWN ON FLOOR PLAN, SECTIONS AND
3.5
FINISH SCHEDULE.
APPLY SKIM COAT PLASTER ON CONCRETE CEILINGS AS SHOWN ON FLOOR PLAN, SECTIONS AND
3.6
ELEVATIONS AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING METAL CANOPY WITH NEW AS SHOWN ON FLOOR PLAN,
3.7
ON DOOR/WINDOW SCHEDULE. (NATURAL COLOR, OAK)
REPLACE DETERIORATED EXISTING WOODEN HEAD, JAM & SILL FOR ALL WINDOWS WITH NEW AS SHOWN
4.6
4.7
4.8
PLANS AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING ALL TOILET ACCESSORIES WITH NEW AS SHOWN ON FLOOR
4.1
4.3
4.4
4.5
4.2
4. MISC. WORK
REPLACE DETERIORATED EXISTING WINDOW HORIZONTAL MINI BLINDS WITH NEW, FIREPROOF TYPE.
SETS AS SHOWN ON NEW FLOOR PLAN AND DOOR SCHEDULE.
REPLACE DETERIORATED EXISTING DOORS AND DOOR FRAMES WITH NEW INCLUDING HARDWARE
AND WINDOW SCHEDULE.
THERMAL BREAKER TYPE WINDOWS INCLUDING GLASS AS SHOWN ON FLOOR PLANS, ELEVATIONS
REPLACE DETERIORATED EXISTING WINDOWS INCLUDING INSECT SCREEN WITH NEW ALUMINUM
AND LOUVER SCHEDULE.
REPLACE DETERIORATED EXISTING ALUMINUM LOUVER WITH NEW AS SHOWN ON FLOOR PLANS
AND SIGNAGE SCHEDULE.
REPLACE INTERIOR & EXTERIOR SIGNAGES WITH NEW AS SHOWN ON FLOOR PLAN, ELEVATIONS
FLOOR PLANS AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING FIRE EXTINGUISHERS CABINETS(FEC) WITH NEW AS SHOWN ON
REPLACE DETERIORATED EXISTING METAL SHELF WITH MOP RACK WITH NEW IN JANITOR ROOM.4.9
4.10
4.11
4.13
4.14
4.15
4.16
4.17
4.12
DRAWING AND SIGNAGE SCHEDULE.
REPLACE DETERIORATED EXISTING BULLETIN BOARD WITH NEW AS SHOWN ON FLOOR PLAN, DETAIL
PLANS, DETAIL DRAWINGS AND INTERIOR FINISH SCHEDULE.
REPLACE DETERIORATED EXISTING UNIVERSAL TV WALL MOUNT WITH NEW AS SHOWN ON FLOOR
REPLACE DETERIORATED ACCESS DOORS WITH NEW ON WALL & CEILING AS REQUIRED.
ON FLOOR PLAN, ELEVATION AND MATERIAL FINISH SCHEDULE.
REPLACE DETERIORATED EXISTING LOCKERS WITH NEW(2TIER) INCLUDING LOCKSET AS SHOWN
4.18
DRAWING.
BASE CABINETS AND UPPER CABINETS AS SHOWN ON FLOOR PLAN, INTERIOR ELEVATION AND DETAIL
REPLACE DETERIORATED EXISTING LAVATORY CABINETS AND KITCHEN CABINET WITH NEW INCLUDING
SHOWN ON FLOOR PLANS, SECTIONS AND DETAIL DRAWINGS.
NORMAL, WATER RESISTANT OR 'X' TYPE) INCLUDING METAL STUDS AND INSULATIONS AS
REPLACE DETERIORATED EXISTING ALL GWB WALL BOARD WALLS WITH NEW GWB WALL (GWB,
NEW CONSTRUCTION (L) WORK
ON FLOOR PLAN AND DETAIL DRAWING.
INSTALL TRENCHES WITH NEW AT MUD AREA, MUD ROOM, EYE WASHERROOM AND LAB AS SHOWN
AND INTERIOR FINISH SCHEDULE.
INSTALL QUARRY TILE INCLUDING QUARRY TILE BASE WITH NEW AS SHOWN ON FLOOR PLANS
ON FLOOR PLAN, INTERIOR ELEVATION AND DETAIL DRAWING.
INSTALL WOODEN SHOWER BENCHS, SHOWER CURBS AND SHOWER CURTAINS WITH NEW AS SHOWN
DETAIL DRAWINGS AND INTERIOR FINISH SCHEDULE.
INSTALL PROJECTION SCREEN AND PROJECTOR MOUNT WITH NEW AS SHOWN ON FLOOR PLANS,
DETAIL DRAWING.
INSTALL SST HANDRAIL, GURARD RAIL, AND SST BOOT SCRAPER AS SHOWN ON FLOOR PLAN AND
ON FLOOR PLANS, ELEVATIONS, SECTIONS AND DETAIL DRAWINGS.
INSTALL RAIN GUTTERS, DOWNSPOUTS AND CONCRETE SPLASH BLOCKS WITH NEW AS SHOWN
ON FLOOR PLAN, ROOF PLAN, ELEVATIONS AND DETAILS.
REPLACE DETERIORATED EXISTING ROOF WITH NEW STANDING SEAM METAL ROOF AS SHOWN
SCOPE OF WORK & GENERAL NOTES
REPAIR BUILDING
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
A-2
,0
11,841
6,6601815,000
,6
,4
1/100
SCALE:
EXST/REMOVAL GROUND FLOOR PLAN
LEGEND
REMOVAL WALL
REMOVE EXISTING WINDOW
& WINDOW FRAME
REMOVE EXISTING DOOR
& DOOR FRAME
REMOVE EXISTING CONC SLAB
EXST/REMOVAL GROUND FLOOR PLAN
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-3
ARCHITECTURAL
NEW GROUND FLOOR PLAN
BUILDING AREA
EXISTING BLDG
NEW WORK AREA
TOTAL
NEW BLDG
REPAIR WORK AREA (1,730 SF) 160.72 SM
(3,730 SF) 346.50 SM
185.78 SM
1/100
SCALE:
NEW GROUND FLOOR PLAN
1/100
SCALE:
NEW GROUND FLOOR PLAN
S S
DS
DS
ROOM
COMM
STORAGE
DN
DN
FEC
DS DS
DS DS DS
SHOWER
M.TOILET/
SHOWER
W.TOILET/
J/C
MUD ROOM
MUD AREA
OFFICE
OFFICE
LAB
WASHER RM
EYE
CORRIDOR
VEST
VEST
,0
,7
,4
,8
CONTAINMENT FL
SECONDARY
23,100
5,8505,2003,8803,8004,370
,0
,6
,9
,1
,4
,7
,1
23,100
6,6506,3004,3005,850
RM
CONFERENCE
MOUNT
TV WALL
LOCKER ROOM
READY / WAITING /
ROOM
MECH/ELEC
FEC
103104
105106
FEC
(2,000 SF)
D7
D2 D9 D8 D1
D5
D6
D4
D3
D10D11
D12
D13
D14
D15
D12
D13
D14
D16
D10
W1 W1 W1
W2W2W2W2W3W3L1
LEGEND
WINDOW FRAME
NEW WINDOW &
DOOR FRAME
NEW DOOR &
CONC WALL
150 MET STUD WALL
200 MET STUD WALL
90 MET STUD WALL
65 MET STUD WALL @ CONC WALL ONLY
DS
W1W1
A-7
A-7
A-5
A-5
A-6
A-6
B/B
B/B
B/B
EWC
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-4
ARCHITECTURAL
P E
R
R O
O F
S L
O P
E
R
R O
O P
E
DS DSDS
STANDING SEAM
METAL ROOFING
W/INSUL ON VR
DS DSDS
GUTTER SLOPE
1 PER 200
GUTTER EXPANSION JOINT
GUTTER SLOPE
1 PER 200
GEJ GEJ GEJDS
DSGEJ GEJ
24,500
,4
ROOF PLAN
SCALE: 1/100
STANDING SEAM
METAL CANOPY
METAL ROOFING
ROOF PLAN
2,700
,0
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-5
ARCHITECTURAL
ELEVATIONS-1
FL
STANDING SEAM
METAL ROOFING
W/ INSUL ON VR
SYSTEM
EXT INSUL & FNSH
FIXED WINDOW
AL BLAST
STANDING SEAM
METAL ROOF
CANOPY
FL
1/100
SCALE:
ELEVATION-1
1/100
SCALE:
ELEVATION-2
GL
GL
STANDING SEAM
METAL ROOFING
W/ INSUL ON VR
SYSTEM
EXT INSUL & FNSH
INSULATED AL DOOR
& GUARDRAIL
SST HANDRAIL
DOWNSPOUT
RAIN GUTTER &
PROTECTED METAL
SST HANDRAIL
EIFS FINISH COAT
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-6
ARCHITECTURAL
ELEVATIONS-2
FL
STL PIPE
PAINT ON
& GUARDRAIL
SST HANDRAIL
SLIDING WINDOW
AL BLAST
& GUARDRAIL
SST HANDRAIL
FL
STANDING SEAM
METAL ROOFING
W/ INSUL ON VR
(TYP)
SYSTEM
EXT INSUL & FNSH
STANDING SEAM
METAL ROOF
CANOPY
DOWNSPOUT
RAIN GUTTER &
PROTECTED METAL
1/100
SCALE:
ELEVATION-3
1/100
SCALE:
ELEVATION-4
GL
GL
ON CONC COLUMN
EIFS COATING ONLY
SYSTEM
EXT INSUL & FNSH
DOWNSPOUT
RAIN GUTTER &
PROTECTED METAL
& GUARDRAIL
SST HANDRAIL
THERMAL INSULATED
METAL DOOR (TYP)
& HANDRAIL
BOOT SCRAPER
EIFS FINISH COATEIFS FINISH COAT
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-7
ARCHITECTURAL
W.P
CONC
TOP OF
POINT
WORKING
BEAM
FL
W.P
,2
,3
LOCKER ROOM
READY / WAITING /
CORRIDOR
RM
CONFERENCE
,0
,0
W1 W2
CROSS SECTION
SCALE: 1/50
FL
W/ INSUL ON VR
(TYP)
STANDING SEAM
METAL ROOFING
METAL ROOF
LINER (TYP)
C
G
H
T
C-100x50x20x3.2
@ 400 OC (MAX)
GALV STL
PROTECTED MET
SHEET FASCIA ON
,4
FL
RM
CONFERENCE
CORRIDOR
VEST
ROOM
COMM
STORAGE
SHOWER
M.TOILET/
J/C
SHOWER
W.TOILET/
C
T
,1
C
T
,4
LONGITUDINAL SECTION
SCALE: 1/50
SEE CIVIL DWG
(BEHIND)
CONC RAMP
W/100THK GLASS FIBER
@ 400 O.C.(MAX)
ON 150 MET STUD
ON 15THK FIRE RATED GWB
PAINT
INSULATION (TYP)
W/ INSUL ON VR
(TYP)
STANDING SEAM
METAL ROOFING
ROOF LINER (TYP)
PROTECTED MET
TOP OF
V A
R ,3
CONC BEAM & SLAB
(TYP)
CONC WALL & CEILING
PAINT ON SCP ON
,6
C
T
,4
C
T
SECTIONS
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-8
ARCHITECTURAL
S S
DSDS
DS
ROOM
COMM
STORAGE
DN
DN
FEC
DS DS
DS DS DS
SHOWER
M.TOILET/
SHOWER
W.TOILET/
J/C
MUD ROOM
MUD AREA
OFFICE
OFFICE
LAB
WASHER RM
EYE
CORRIDOR VESTVEST
RM
CONFERENCE
MOUNT
TV WALL
LOCKER ROOM
READY / WAITING /
ROOM
MECH/ELEC
FEC
101116
FEC
W1
D2 D9
D8 D1
D5
D6
D4
D3
D10D11
D12
D13
D14
D15
D12
D13
D14
D16
D10
W1 W1 W1 W1
W2W2W2W2W3W3L1
9001,8001,4001,8001,7001,8001,0001,8002,2001,8001,2506,0502,0001,500
,4
,2
,0
,0
,1
,5
,0
,0
,9
,7
1,2001,2001,5001,2001,4001,2001,7001,2006509509002,0302,0709001,0304,370
,7
,0
,9
2,2502,2501,0005501,0004,8571,0004039003,3191,0006651,0008052,100
3,0501,0005501,0008,0501,0006321,0002,318
,6
,9
2,650
,1
4,000
,4
,1
2,1501,820
SCALE:
ENLARGED FLOOR PLAN
1/50
SLOPE SLOPE
2,600
1,900
,2
ENLARGED FLOOR PLAN
B/B
B/B
B/B
& HANDRAIL
BOOT SCRAPER
(TYP)
COVERED TRENCH
AL. GRATING
(TYP)
COVERED TRENCH
SST GRATING
EWC
LEGEND
WINDOW FRAME
NEW WINDOW &
DOOR FRAME
NEW DOOR &
CONC WALL
150 MET STUD WALL
200 MET STUD WALL
90 MET STUD WALL
65 MET STUD WALL @ CONC WALL ONLY
150 MET STUD WALL W/100T INSULATION
200 MET STUD WALL W/100T INSULATION
D7
SMLD
LAV
SHOWER
M.TOILET/
SHOWER
W.TOILET/
J/C
D13D15D13
W3
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
LAV 865
800TTD
865SD
STD MTG HGTTOILET ACCESSORYABBREV.
WC 381~432
(IN MM ABOVE FFL)
MIRROR GLASS (TO BOTTOM) FOR COUNTER
MIRROR GLASS (TO TOP)
MG
(RECESSED DUAL ROLL)
SOAP DISPENSER (COUNTER TOP)
COUNTER TOP LAVATORY (TO RIM)
WATER CLOSET (SEAT TOP)
TP TOILET PARTITION (TO TOP)
HANDICAP MTG HGT
432-483
(IN MM ABOVE FFL)
QUANTITY
SEE ELEVS. & PLANS
SEE ELEVS. & PLANS
SEE ELEVS. & PLANS
SEE ELEVS. & PLANS
SEE ELEVS. & PLANS
SEE ELEVS. & PLANS
SERVICE SINK (TO RIM)
SS
PTDWR
UR
SND SANITARY NAPKIN DISPOSER (TO TOP)
MOP RACK
MR 1800
URINAL (TO RIM)
PAPER TISSUE DISPENSER W/RECEPTACLE
SEE ELEVS. & PLANS
SEE ELEVS. & PLANS
SEE ELEVS. & PLANS
SEE ELEVS. & PLANS
SEE ELEVS. & PLANS
ACCESSORY MOUNTING HEIGHT SCHEDULE
US URINAL SCREEN (TO TOP) SEE ELEVS. & PLANS1500 1500
EWC ELECTRIC WATER COOLER (TOP SPOUT) 1050 885 SEE ELEVS. & PLANS
GRAB BARGB - 915 SEE ELEVS. & PLANS
(TO PAPER HOLE)
TOILET TISSUE DISPENSER (TO CENTER)
SOAP DISPENSER (TO BOTTOM)SD
MIRROR GLASS (TO BOTTOM)MG
LAVATORY (TO RM)LAV
SEE ELEVS. & PLANS
SEE ELEVS. & PLANS
SCALE: 1/50
PLAN FOR TOILETS
ENLARGED PARTIAL FLOOR
2002,0801,6002001,6002,200200 ,8
,4
,3
2,1601,7203,800
8759002,1052,215900685
D14 D14
8401,2181,8221,6311,520650
PTDWR
PTDWR
TB
TB
,7
D
A
B
C
KEY
ELEVATION
INTERIOR
TTD
WC
SND
TP
UR
,4
MG
TTD
SD SDGB GB
WC
TTDSND
TP
LAV
PTDWR
WC
US
SCALE: 1/50
INTERIOR ELEVATIONS (MEN TOILET 106 )
A B C D
SCALE: 1/50
INTERIOR ELEVATIONS (WOMEN TOILET 104 )
TB
TTD
WC
SND
TP
LAV
SDSDSD
PTDWR
MG
BENCH
SHOWER
TB
,4
A B
TTD
WC
SND
TP
LAV
GB
SC/R
C D
D
SCALE: 1/50
INTERIOR ELEVATIONS JANITOR 105 )
M
R
C K
S
IN
K
,8
MR
SSSS
MR
C
ARCHITECTURAL
A-9
INTERIOR ELEVATIONS - 1
ENLARGED FLOOR PLAN AND
GCWT-1
GCWT-1
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
DS DS
MOUNT
TV WALL
LOCKER ROOM
READY / WAITING /
W1W1 W1
A-10
B
A-10
A
SCALE: 1/50
ENLARGED PARTIAL FLOOR PLAN
5501,0008,0501,000200
6,3004,150
SCALE:
INTERIOR ELEVATIONS AT LOCKER ROOM
1/25
,7
B
M/W
A-14
A-14
A-14
,4
3,300
EQ EQ EQ 950
,4
,8
,2
A-14
SCALE: 1/25
A
INTERIOR ELEVATIONS AT KITCHEN CABINET
ARCHITECTURAL
A-10
INTERIOR ELEVATIONS - 2
ENLARGED FLOOR PLAN AND
ON 150 MET STUD
15 THK GWB
@ 400 OC (MAX)
PAINT ON
(GFGI)
REF
EWC
EWC
(GFGI)
(CFCI)
SEE MECH DWG
ON 150 MET STUD
15 THK GWB
@ 400 OC (MAX)
PAINT ON
D12 D12
GCWT-2
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-11
ARCHITECTURAL
KEY PLAN
A-11
1A
A-11
1B
1C
A-11
1D
A-11
W.P
,0
,0
,3
1A
1/25
EXTERIOR WALL SECTIONS
SCALE:
LINER (TYP)
METAL ROOF
,4
C
T
EIFS
WINDOW W/
INSECT SCREEN
INSULATED AL
BLAST SLIDING
MINI BLIND
SCHEDULE
FINISH PER
& SILL (TYP)
WOODEN HEAD, JAMB
OAK
ON 65 MET STUD
15 THK GWB
W/ INSUL ON VR
@ 400 OC (MAX)
SCHEDULE
FINISH PER
POINT
WORKING
TOP OF
CONC BEAM
FL
C-100x50x20x3.2
@ 400 OC (MAX)
GALV STL
PROTECTED MET
SHEET FASCIA ON
SEE CIVIL DWG
(BEHIND)
CONC RAMP
1B
3,200
SCHEDULE
FINISH PER
INSULATED AL
& GUARDRAIL
SST HANDRAIL
DOOR
3,000
MET CANOPY
STANDING SEAM
GALV STL
SHEET SOFFIT
C-100x50x20x3.2
@ 400 OC (MAX)-TYP
PROTECTED MET
PROTECTED MET
SHEET FASCIA
FL
1C
,4
,7
GL
1,900400 400
,6
POINT
WARKING
DWG
SEE CIVIL & STRUC
ON CONC COLUMN
EIFS COATING ONLY
ON CONC COLUMN
EIFS COATING ONLY
PAINT ON STL STRUC
CONC
TOP OF
POINT
WORKING
BEAM
FL
W.P
,3
,2
1D
LINER (TYP)
METAL ROOF
SCHEDULE
FINISH PER
INSULATED AL
BLAST FIXED
WINDOW
& SILL (TYP)
WOODEN HEAD, JAMB
OAK
EIFS
ON 65 MET STUD
15 THK GWB
@ 400 OC (MAX)
QURRY TILE
3,200
W/ 50T INSUL ON VR
,6
W/ INSUL ON VR
(TYP)
STANDING SEAM
METAL ROOFING
S S
DN
DN
FEC
CONTAINMENT FL
SECONDARY
MOUNT
TV WALL
FEC
FEC
EXTERIOR WALL SECTIONS
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
SCALE: 1/25
INTERIOR WALL SECTIONS-1 ARCHITECTURAL
A-12
MOUNT
TV WALL
KEY PLAN
A-12
1A
A-12
1F
1C
A-12
VCB VCB
SEE STRUC DWG
CONC WALL & FOOTING
,1
100THK GLASS FIBER
INSULATION(30KG/m)
(TYP)
ROOF LINER PANEL
PROTECTED METAL
STORAGE
CORRIDOR
ON 12 THK
PAINT
ON CONC SLAB (TYP)
ON CEMENT MORTAR BED
ON WATERPROOFING MEMBRANE
FCT ON CEMENT BOND COAT
ON 12 THK
PAINT
W/GWB CEILING W/GWB CEILING
,4
(TYP)
200MM MTL STUD @ 300 O.C
ON 12THK CEMENT BOARD W/
ON PLASTERING W/MTL LATH
ON WATERPROOFING MEMBRANE
GCWT ON CEMENT BOND COAT
SHOWER
M.TOILET/
SHOWER
W.TOILET/
VCB
(TYP)
ROOF LINER PANEL
PROTECTED METAL
CORRIDOR
PVCT
VCB
PVCTPVCT
& CEILING
ON CONC WALL
SKIM COAT PLASTER
PAINT ON
PVCT
LOCKER ROOM
READY / WAITING /
100THK GLASS FIBER
INSULATION(30KG/m)
,4
ACST ACSTACST
1A
1C1B
A-12
1D
VCB
PVCT
VCB
PVCT
LOCKER ROOM
READY / WAITING /
100THK GLASS FIBER
INSULATION(30KG/m)
@ 400 O.C.(MAX)
150 MET STUD
15THK GWB ON
PAINT ON
,4
ACSTACST
1D
OFFICE
1E
A-12
ON 12 THK
PAINT
ON 12 THK
PAINT
W/GWB CEILING W/GWB CEILING
,4
(TYP)
200MM MTL STUD @ 300 O.C
ON 12THK CEMENT BOARD W/
ON PLASTERING W/MTL LATH
ON WATERPROOFING MEMBRANE
GCWT ON CEMENT BOND COAT
1E
1D
A-12
,4
MUD ROOM
LAB
SEE STRUC DWG
CONC WALL & FOOTING
,1
& CEILING
ON CONC WALL
SKIM COAT PLASTER
PAINT ON
1F
,4
SHOWER
M.TOILET/
ON 12 THK
PAINT
W/GWB CEILING
ON CONC SLAB (TYP)
ON CEMENT MORTAR BED
ON WATERPROOFING MEMBRANE
FCT ON CEMENT BOND COAT
(TYP)
200MM MTL STUD @ 300 O.C
ON 12THK CEMENT BOARD W/
ON PLASTERING W/MTL LATH
ON WATERPROOFING MEMBRANE
GCWT ON CEMENT BOND COAT
ROOM
MECH/ELEC
EPOXY
INTERIOR WALL SECTION
15THK GWB
PAINT ON
EPOXY EPOXY
@ 400 O.C.(MAX)
ON 150 MET STUD
PAINT ON 15T GWB
@ 400 O.C.(MAX)
ON 150 MET STUD
PAINT ON 15T GWB
W/ INSUL ON VR
(TYP)
STANDING SEAM
METAL ROOFING W/ INSUL ON VR
(TYP)
STANDING SEAM
METAL ROOFING
S S
DN
DN
FEC
CONTAINMENT FL
SECONDARY
FEC
FEC
A-13
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
WORKING POINT
EAVE F
LASHIN
G
CONC BEAM
TOP OF
INSUL ON
VAPOR RETARDER
TRIM
(TYP)
MASTIC
AXIS
BLOCKING NAILER
P.M CAP FLASHIG
P.M BASE FLASHING
50x150 TREATED WOOD
100 FLANGE (ALL AROUND)
18 GA GALV MET CURB W/
P.M FLASHING
W/CRICKET
OUTLINE OF
(SEE MECH DWG)
MECH EQUIPMENT
MET F
LASHIN
G
SEALANT
SEALANT
CURB OPENING
M
IN
STANDING SEAM
METAL ROOFING
W/INSUL ON VR
PROTECTED METAL
EAVE FLASHING
(TYP)
G1 WIRE BASKET
STRINGER @ EACH
DOWNSPOUT (TYP)
PROTECTED
METAL FASCIA ON
GALV METAL
C-100x50x20x3.2
@ 1200 OC (MAX)
ON INSUL & VR
SEALANT W/
BACK-UP ROD
EXT INSUL &
FNSH SYSTEM
PROTECTED METAL
DOWNSPOUT
PROTECTED MET
SOFFIT ON GALV MET
C-200X75X25X3.2
@ 1200 OC (MAX)
W/ INSUL ON VR
PROTECTED MET
STRAP HANGER
@ 900 OC
25X3 THK
BRACKET HANGER
@ 900 OC
W.P
(MIN
ZEE TRIM
W/ SEALANT
STL CHANNEL
FRAMING
(SAME SIZE AS STL
PURLIN)
RIGID INSULATION
(ALL AROUND
OUTSIDE OF CURB)
PROTECTED METAL
RAKE FLASHING
STANDING SEAM
METAL ROOFING
W/INSUL ON VR
PROTECTED
METAL TRIM
PROTECTED MET
WATER DRIP
PROTECTED
METAL FASCIA
ON GALV MET
ON INSUL & VR
PROTECTED METAL SOFFIT
C-200X75X25X3.2 ON GALV
MET @ 1200 OC (MAX)
W/ INSUL ON VR
EXT INSUL &
FNSH SYSTEM
SEALANT W/
BACK-UP ROD
100 THK TREATED
WOOD NAILER
W/ 12 DIA EXP BOLT
@ 1200 OC (MAX)-TYP
HOOK OVER
ZEE TRIM &
RIVET TO ZEE
CLOSURE
W/ SEALANT
PROTECTED MET
CAP FLASHING
T
EAVE DETAIL1A
METAL CURB DETAIL
RIDGE DETAIL1E
EAVE DETAIL1C
SCALE:
ROOF DETAILS
1/10
LINING PANEL
PROTECTED METAL
LINING PANEL
PROTECTED METAL
LINING PANEL
PROTECTED METAL
PROTECTED METAL ROOF
SELF DRILLING FASTENERS
FLEXIBLE
ALUMINUM BASE
M
IN
PIPE FLASHING
EDPM
STANDING SEAM
METAL ROOFING
W/ INSUL ON VR
(TYP)
PIPE FOR ANTENA
1D
FOR ANTENA DETAIL
PIPE THRU ROOF
1B
ARCHITECTURAL
ROOF DETAILS
CEILING LINE
PULL @ EACH DOOR
(B02011) 10 DIA POLISHED
20x100
(TYP)
WD SHIM
PLASTIC LAMINATE (PL-1)
(TOP,BOTTOM, & EDGE)
ON 18 THK PLYWOOD
REF (GFGI)
7.5 THK PLYWOOD (FRONT)
PLASTIC LAMINATE (PL-2)
BRASS ROD
50x100 WD FRAME (TYP)
PLASTIC LAMINATE (PL-1)
ON 18 THK PLYWOOD (FRONT)
ON METAL STUD WALL
ON 12 THK CEMENT BD
GCWT ON THINSET MORTAR
ON 12 THK CEMENT BD
5C
5B 5D
5A
L-50x50x6x50LG STL
PLASTIC LAMINATED (PL-2)
ON 18 THK PLYWD(TOP)
ON 7.5 THK PLYWD
PLASTIC LAMINATED (PL-2)
EXP BOLT @ 450 OC
FIXED TO WD BLOCK &
TO CONC SLAB W/6 DIA
50x100 WD
BLOCK
SILICONE SEALANT
30x50 HARDWD
18X18 HARDWD TRIM
W/ PLASTIC LAMINATED
POST-FORMED 13 THK
ON 18 THK PLYWOOD
MARINE EDGE
(FRONT, BACK & EDGE)
PLASTIC LAMINATED
ON 18 THK PLYWD
SOLID SURFACING (SSM-1)
DRAWER STOPPER
20x40 HARD WD
W/ PLASTIC
LAMINATED
(TOP)
ON 7.5 THK PLYWD
PLASTIC LAMINATED (PL-2)
50x100 WD BLOCK
WD BLOCK & TO
CONC SLAB W/
6DIA EXP BOLTS
@ 450 OC
L-50x50x6x50LG STL
CLIP FIXED TO
18 x 18
VCB
PLASTIC
PLYWD
& EDGE)
ON 7.5 THK PLYWOOD
ON 18 THK PLYWOOD
POST-FORMED 13 THK
SOLID SURFACING (SSM-1) MATERIAL
(FRONT)
HARDWD TRIM
ON 18 THK
LAMINATED (PL-1)
(FRONT, BACK
W/ PLASTIC
LAMINATED (PL-1)
(TOP & EDGE)
MATERIAL
(PL-1)
A-14
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
SCALE: 1:10
SCALE: 1:10
UPPER CABINET DETAIL
SCALE: 1:5
D E T A I L S
PLASTIC LAMINATED (PL-2)
GCWT ON CEMENT BOND COAT
CABINET DETAILS
C
T
C
T
50x100
TREATED WD
FRAME
PLASTIC LAMINATED (PL-1) ON
18 THK PLYWOOD (FRONT)
MICROWAVE(GFGI)
(VERIFY SIZE)
PLASTIC LAMINATED (PL-1)
ON 18 THK PLYWOOD
(TOP, EDGE & BOTTOM)
20x100
TREATED
WD SHIM
ON METAL STUD @ 400 OC (MAX)
PLASTIC LAMINATED (PL-2)
INTERIOR 18 THK PLYWOOD
(TOP & EDGE)
PLASTIC LAMINATED (PL-2)
INTERIOR ON 7.5 THK PLYWOOD
(FRONT)
PLASTIC LAMINATED (PL-1) ON 18
THK PLYWOOD (FRONT & EDGE)
W/ HINGE (2PR-BO1602)
W/ (@ EACH DOOR)
PULL @ EACH DOOR (B02011)
10 DIA POLISHED BRASS ROD
MARINE EDGE
13 THK SOLID SURFACE (SSM-1)
MATERIAL OVER 18 THK PLYWOOD
(COUNTERTOP, BACK & SIDE
SPLASH GUARD)
METAL
ADJUSTABLE
PLASTIC LAMINATED
INTERIOR
ON 18 THK PLYWOOD
(TOP,BOTTOM & EDGE)
25X50 WD
SEALANT
PLASTIC LAMINATED (PL-1)
N 18 THK PLYWD (FRONT & EDGE
W/ HINGES 2PR - B01602 @ EACH DOOR)
PLASTIC LAMINATED (PL-2)
INTERIOR ON 18 THK PLYWD (BOTTOM & EDGE)
PLASTIC LAMINATED (PL-2)
INTERIOR ON 18 THK PLYWOOD
(TOP,BOTTOM & EDGE)
PLASTIC LAMINATED (PL-2)
INTERIOR ON 7.5 THK PLYWOOD (FRONT)
MET ADJ SHELF HARDWARES
(B04071 & B04081)
PULL @ EACH DOOR (B02011)
10 DIA POLISHED BRASS ROD
PLASTIC LAMINATED (PL-1)
ON 18 THK PLYWOOD
(BOTTOM)
20x100
TREATED
WD SHIM
13 THK SOLID SURFACE (SSM-1)
MATERIAL OVER 18 THK
PLYWOOD (COUNTERTOP, BACK &
SIDE SPLASH GUARD)
MARINE EDGE
KITCHEN SINK (UNDER HUNG TYPE)
(SEE MECH DWG)
PLASTIC LAMINATED (PL-2)
INTERIOR 18 THK PLYWOOD
(TOP & EDGE)
PLASTIC LAMINATED (PL-2)
INTERIOR ON 7.5 THK PLYWOOD(FRONT)
PLASTIC LAMINATED (PL-1)
ON 18 THK PLYWOOD (FRONT & EDGE)
W/ HINGE (2PR-BO1602 @ EACH DOOR)
PULL @ EACH DOOR (B02011)
10 DIA POLISHED BRASS ROD
SEALANT
25X50 WD
PLASTIC LAMINATED (PL-2)
INTERIOR ON 18 THK PLYWOOD
(TOP,BOTTOM & EDGE)
PULL @ EACH DOOR (B02011)
10 DIA POLISHED BRASS ROD
50x100
TREATED WD
FRAME
CEILING LINE
CEILING LINE
@ 400 OC (MAX)
GWB (WATERPROOF) ON METAL STUD
GCWT W/CEMENT BOND COAT ON 15THK
@ 400 OC (MAX)
GWB (WATERPROOF) ON METAL STUD
GCWT W/CEMENT BOND COAT ON 15THK
1/10
SCALE:
CABINET DETAIL
5C
A-14
5D
A-14
5A
5B
5D
1/10
SCALE:
CABINET DETAIL
BOLTS @600 OC
X50 LG W/ 12DIA EXP
CONTINUOUS TREATED
50X100 WD & 50X50X6
C
T
(TYP)
(PL-1).
PLYWD PANEL W/ PLASTIC LAMINATE
CONSTRUCTED OF SOLID WD TRIMS &
END PANEL AND ETC. SHALL BE
INCLUDING DOOR, DRAWER FRONTS, SIDE
ALL EXPOSED COUNTER CABINET FACES
5.
6.
(PL-2).
FINISHED W/ PLASTIC LAMINATE
ALL CABINET INSIDE SURFACE SHALL BE
7.
FOR THE SOUND SILENCE.
EQUIPPED WITH RUBBER BUMPER
ALL CABINET DOORS SHALL BE AND TO BE INSTALLED BY OTHER.
GOVERNMENT FURNISHED MATERIALS
MICROWAVE,RANGE AND REFRIGERATOR WILL BE 1.
2.
3.
4.
FINISHED W/ SOLID SURFACE MATERIAL (SSM-1).
ALL CABINET COUNTERTOP SHALL BE
8.
SOLID SURFACE MATERIALS FOR APPROVAL.
OF HARDWARE, PLYWOOD, PLASTIC LAMINATE &
AND TEST REPORTS, CERTIFICATIONS
OF KITCHEN CABINETS WITH HARDWARE,
CONTRACTOR SHALL SUBMIT SHOP DRAWING
TWO (2) INCHES ACTURAL SIZE OF THE REF.)
JOB SITE, (REFRIGERATOR SPACE SHALL BE
AND CABINET SIZE SHALL BE ADJUSTED ON THE
REFRIGERATOR DIMENSION IS APPROXIMATE
BY USING AGENCY.
PLASTIC LAMINATED COLOR SHALL BE SELECTED
CABINET NOTE
SSM-1
OR APPROVED EQUAL
MELATON, 1157EA
PLASTIC LAMINATED SHEET
OR APPROVED EQUAL
MELATON, 3357EA
PLASTIC LAMINATED SHEET
PL-1
PL-2
OR APPROVED EQUAL
CRYSTAL PACIFIC, #NP932
LOTTE STARON MFG,
SOLID SURFACE MATERIAL
PLYWOOD
SIDE SPLASH)
MARINE EDGE
ON 18 THK
(2PR-B05011
@ EACH DOOR)
VCB
PLYWOOD (TOP & EDGE)
(COUNTERTOP, BACK &
13 THK SOLID SURFACE
ON 18 THK PLYWOOD
METAL PULL (B02011)
DRAWER W/ SLIDE
PLASTIC LAMINATE (PL-1)
5D
5A
5C
5B
PLASTIC LAMINATE (PL-2)
MATERIAL (SSM-1) OVER 18 THK
5E
LOWER CABINET DETAIL
A-14
A-14
A-14
A-14
A-14
A-14
A-14
A-14
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
GCWT FINISH WALL
C
T
25 THK WD
3A
3B
1/5
CWT FINISH
WOOD SHIM
ELEVATION
SCALE : NONE
WALL OVERALL SIZE
SECTION
SCALE:
W/MFR PER SPEC
NOTE
VERIFY DIMENSION
DRY WALL
6 DIA MET SCREW
(3-PER SIDE)
(ALL AROUND)
SCALE:
AS SHOW
2A 2B
2B
SCALE :
MIRROR DETAILS
1/2
SLAB
ON CONC
MORTAR BED
CEMENT
FT ON
PLYWD
MIRROR ON 7.5 THK
(SEE ELEC DWG)
LIGHTING FIXTURE
(MAX)-TYP
600 OC
TOGGLE BOLT @
3EA-18 DIA
DWG)
H/C (SEE MECH
LAVATORY FOR
STUD
ANCHOR TO MET
STL PLATE
550x(L)x6 THK
PAPER TOWEL DISPENSER W/RECEPTACLE DETAILS
3A
3B
6 THK MIRROR ON
7.5 THK PLYWOOD
W/ GLUE
12 THK CEMENT
BOARD
SST FRAME
SEALANT
6 THK MIRROR ON
7.5 THK PLYWOOD
W/ GLUE
12 THK CEMENT
BOARD
SST FRAME
SEALANT
POST-FORMED
13 THK SOLID
SURFACING
MATERIAL
SCALE: 1/10
LAVATORY COUNTER DETAIL
205 275 150
OVER 18 THK
TOP & SPLASH BACK
MATERIAL COUNTER
SOLID SURFACING
POST-FORMED 13 THK
1/5SCALE:
SST SHELF BRACKET
MOP HOLDER
HOOK
SST HOOK
@ 215 OC FOR TOP SHELF
W/2-6 DIA TOGGLE BOLTS
2-16 GA SST SHELF BRACKET
SST MOP HOLDER
18 GA SST SHELF
METHODS OF WALL
FASTENING
SCALE: 1/5
@ 215 OC FOR TOP SHELF
4B
@ 1200 OC
DRYING ROD
DRYING ROD
SCALE : 1/5
MOP RACK DETAILS
4A
4B
ELEVATION
SECTION
300215
75 215
182.5
VAR
THK PLY WOOD
PLASTIC ON 12
REMOVABLE PANEL
(TYP)
SST TUBE FRAME
-50x50x6
A-15
ARCHITECTURAL
MISC DETAILS - 1
GCWT FINISH WALL
WALL
GCWT FINISH
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-16
ARCHITECTURAL
MISC DETAILS - 2
VARI
ES
(S
EE I
NTE
RI
OR
ELE
VATIO
N)
GRAB BAR
32 DIA SST
GRAB BAR ISOMETRIC
NOT TO SCALE
62 C
LE
A R
SCALE :
STUD WALL MOUNTING
SCALE:
GRAB BAR DETAILS
AS SHOW
3A 3B
1/2 SCALE :
TOILET PANEL MOUNTING
3C
1/2
TO METAL STUD
METAL STUD
6 THK GALV STL
PLATE ANCHOR
CWT WALL FINISH
12 THK CEMENT BOARD
32 DIA SST GRAB BAR
SST GRAB BAR FLANGE
6 x 25 OVAL HEAD
SST BOLT
SST CONNECTOR
SPACER THREADED
SST GRAB BAR FLANGE
SST PILASTER
THREADED
32 DIA SST GRAB BAR
SST CONNECTOR SPACER
OVAL HEAD SST
MACHINE SCREW
SST BACK
PLATE
IN
S
ID
B
X
D
IM
PULL (TYP)
SIDE)-TYP
METAL DOOR
6 DIA METAL
SCREW (3-PER
SCHEDULE
SCHEDULE
FINISH PER
FLAT TRIM
FINISH PER
(ALL AROUND)
WOOD SHIM
V
E R
IF
Y
(OUTSIDE TRIM DIM)
(INSIDE BOX DIM) W/ METAL LATH
FLAT TRIM
CONC FILL
IN
S
WOOD SHIM
(ALL AROUND)
DOOR PULL
CASING BEAD
(ROUGH OPENING)
1C 1B
(TYP)
METAL
DOOR PULL
TEMPERED SAFETY
METAL TRIM
L
F I R E
E X T I N G U I S H E R
GLASS
W/ METAL LATH
CONC FILL
(INSIDE BOX DIM)
30 30
45300
(INSIDE BOX DIM)
0 (
IN
S
(OUTSIDE TRIM DIM)
0 ( O
U T S
PAINT SCP
PLAN
SECTION "A-A"ELEVATION
EXTINGUISHER CABINET
METAL DOOR PULL
(OUTSIDE TRIM DIM)
O
U T S
METAL TRIM
GLASS
METAL FIRE
(ALL AROUND)
WOOD SHIM
METAL DOOR
PULL
(OUTSIDE TRIM DIM)
METAL DOOR
PULL
(ALL AROUND)
WOOD SHIM
A
A
SCREW (3-PER SIDE)
PAINT ON SCP
SCALE:
1/10
FIRE EXTINGUISHER CABINET DETAILS - 1
1C 1B
ELEVATION
A-A SECTION
1A
PLAN
1A
1B 1C
(INSIDE BOX DIM)
(ROUGH OPENING)
30030 30
SCALE: N/A
FIRE EXTINGUISHER CABINET DETAILS - 2
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-17
ARCHITECTURAL
MISC DETAILS - 3
SCALE:
4 1/10
CONC SPLASH BLOCK DETAIL
DOWNSPOUT
PROTECTED MET
GUTTER EXPANSION DETAILS
FRAME
1G
TO INSURE BOARD EDGES ARE TIGHTLY BUTTED.
STANDARD BOARD THICKNESSES 18, 25, 35 & 50 STANDARD
FACTORY EDGES AT CORNERS, OPENING, GRADE LINE ETC.
BOARD SIZES 600x1200, 600x2400 & 1200x2400 USE
NOTES :
1.
INSULATION BOARD
& BONDING AGENT
MECHANICAL FASTENERS
SPRAY COLOR SEALER
BASE COAT
FINISH COAT
1BNOTE
REINFORCING MESH FABRIC
OPEN WEAVE GLASS FIBER
INSTALLATION OF INSULATION & FINISH SYSTEM
APPLIED AT 45 ANGLE
OF FIBERGLASS MESH
USE 150x300 STRIPS
OPENING REINFORCEMENT
AESTHETIC JOINT
INSU. BOARD LAYOUT
GROOVE
1C
V-CUT AESTHETIC
OPENING
1F
1J
REINFORCEMENT
CORNER
1E CORNER DETAIL
SEALANT
JAMB CONDITION
HEAD / JAMB1D
DOOR OR WINDOW
CORNER DETAIL
METAL MESH
EXPANDED
CONTROL JOINT
METAL MESH
EXPANDED
LANDING
STAIR
SEALANT
JAMB CONDITION
SILL
1H
1K
CONTROL JOINT WITH BACKSTOP & SEALANT.
INSTALLED IN LINE WITH INSULATION & PLASTER FINISH
EXTERIOR CONC WALL CONTROL JOINTS SHALL BE 2.
CONC WALL
1.CORNERS ARE TO BE
FACTORY CUT EDGES
& NO FIELD CUTS
ON EXPOSED EDGES
WILL BE PERMITTED
AND THERE IS TO BE
NO GAP BETWEEN BOARDS
NOTE :
2.INSULATION BOARD SHALL
STAGGERED AT VERTICAL JOINT
AND INTERLOCKED AT CORNER.
W/ DRAINAGE SYSTEM.
1A
SCALE:
SCALE:
1/5
DOWNSPOUT DETAILS
METAL SCREEN
REMOVABLE
THE GUTTER & TO MEET AT/FP REQUIREMENTS.
3. TO PREVENT LEAVES FROM COLLECTING IN
2. INSTALL REMOVABLE METAL SCREEN
AT ALL GUTTERS.
SHOULD NOT BE EXCEEDED MAX 12,000mm.
1. DISTANCE BETWEEN GUTTER EXPANSION JOINTS
*NOTE
STANDING SEAM
ROOFING
SOLDER
RIVET &
GUTTER
CONTINUOUS
CLEAT
SLOPE
1/16 PER FT
SECTION A-A
1/16 PER FT
SLOPE
A
A
SLOPE
MET
GUTTER
ENDS
GUTTER LAP
THAN BACK (MIN)
FRONT 12 LOWER
SEALANT W/
BACKING ROD
3 THK X 50 W
SST STRAP
@ 900 OC
(TYP)
9 DIA EXP BOLT
75 W X 150 H X 5 THK
SST PLATE (TYP)
EXT INSUL &
FNSH SYSTEM
PROTECTED
METAL DS
(150 x 100) 6 DIAx80 RUST
PROOF CAP
SCREW & NUT
W/WASHER (TYP) 1.5 THK X 50 W
PROTECTED METAL
DS STRAP HANGER
@ 900 OC (MAX)
SCALE: N/A
TYPICAL EIFS DETAILS
N/A
URINAL SCREEN DETAILS
AS SHOWNSCALE:
D E T A I L
SCALE : 1/2
P L A N
SCALE : 1/20
E L E V A T I O N
SCALE : 1/20
WALL FASTENING
& SEX NUT
SHOULDER SCREW
BRACKET
AS REQ'D
SST PILASTER
3A
3B 3C
3B
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-18
ARCHITECTURAL
MISC DETAILS - 4
SEALANT
BASE FLASHING
PROTECTED MET
PROTECTED
METAL
"Z" CLOSURE
EIFS ON 12 THK
CEMENT BOARD
ON C-100x50x20x2.3
STL CHANNEL
@ 400 OC
100 THK TREATED
WD NAILER
80x80x7.0THK STEEL
ANGLE FRAME
@ 850 OC
METAL STRAP HANGER
@ 900 OC (MAX)
(RIVET TO GUTTER EDGE)
PROTECTED MET GUTTER
25 W x 3 THK
BRACKET HANGER @
900 OC(MAX)
(STAGGERED W/
STRAP HANGERS)
C-100x50x20x2.3
W.P
15THK STL PLATE
EIFS
1/10SCALE:
25 150
EAVE FL
ASHING
1,400
METAL CANOPY DETAIL
PROTECTED METAL
ROOFING CANOPY
PROTECTED MET SOFFIT
SCALE:
SHOWER CURB DETAIL
1 : 5
BATH ROOM
R=5
SEALANT
SHOWER AREA
SHOWER CURTAIN
SLOPE SLOPE
SHOWER CURTAIN
W/ROD
FABRIC REINF
EXST CONC OR BRICK CURB
MEMBRANE
WATER PROOFING
CEMENT MORTAR
BED
CERAMIC FLOOR
TILE
MEMBRANE
WATER PROOFING
CEMENT MORTAR
BED
CERAMIC FLOOR
TILE
SHOWER CURTAIN
W/ROD
W/ADHESIVE
12 THK SSM
L
5B 5A
SECTIONP L A N
6 THK CEMENT BOARD
6 THK CEMENT BOARD
PORCELAIN SOAP HOLDER
MORTAR BED
CERAMIC TILE
SOAP HOLDER
PORCELAIN
SCALE: 1:10
SOAP HOLDER DETAILS
GCWT ON
CEMENT BOND COAT
ON WATERPROOFING
MEMBRANE ON
PLASTERING W/METAL LATH
GCWT ON
CEMENT BOND COAT
ON WATERPROOFING
MEMBRANE ON
PLASTERING W/METAL LATH
SCALE:
TOWEL BAR DETAILS
O O
R
FLANGE
TOWEL BAR
TOWEL BAR
,3
CONC WALL
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A-19
ARCHITECTURAL
BAR @ 100 O.C
5x5 THK CROSS
AHR ROD @ 600
BAR @ 15 O.C
25x5 THK BEARNG
150 150
6THK x 50 SST
MOLTEN LEAD
2.0 THK SST PLATE
SST COLLAR
BOOT SCRAPER
WELD TO SLEEVE
SST SLEEVE
SST HANDRAIL
280.5 300 300 280.5
"A"
"A"
300 3001
M
IN
M
X
SCALE: 1/5
BOOT SCRAPER DETAIL
1/5
ELEVATION
SCALE : NONE
SCALE:
1A
1B
1/5SCALE:
1C
D E T A I L
SECTION "A"-"A"
1B
SCALE: 1/10
TRENCH DETAIL
MISC DETAILS - 5
D13-7EA
D13 @ 300 O.C
400 or 650
±700 or 950
SEE STRUC DWG
CONC SLAB
*NOTE*
SCALE: 1/5
1.5 THK SST TRENCH BODY
SST TRENCH DETAIL
1000L X 400W X 44H, 50X50X4 ANGLE
EPOXY ON CONC
±400
SEE STRUC DWG
CONC SLAB
3 THK SST GRATING TRENCH COVER
3 THK SST GRATING TRENCH COVER
2.
CONNECTION DETAIL TO SHOP DRAWING FOR REVIEW AND APPROVAL.
PRIOR TO INSTALL NEW TRENCH DRAINS, CONTRACTOR SHALL SUBMIT THE DRAIN PIPE
1.
SCALE: N/A
SAMPLE PICS OF SST TRENCH
SST TRENCH: WWW.NAMJITRENCH.COM OR APPROVED EQUAL.3.
CONTRACTING OFFICER BEFORE FABRICATION AND INSTALLATION.
SST TRENCH COVER, ANCHOR BOLT, ACCESSARIES & ETC FOR APPROVAL BY THE
THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ACTUAL SST TRENCH BODY,
10±40010
25±35025
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
1.
WITH THE CAMP CASEY EXTERIOR COLOR SCHEME AS APPROVED BY THE COR.
SELECTION OF EXTERIOR PAINT AND FACTORY APPLIED COLORS SHALL BE IN ACCORDANCE
MANUFACTURERS STANDARD MUST APPROACH.
COLOR IS NOT REQUIRED. THE SELECTIONS SERVE ONLY TO INDICATE THE COLOR WHICH THE
INTENDED TO LIMIT SELECTIONS OF PRODUCTS. AN EXACT MATCH OF THE MANUFACTURERS
MANUFACTURERS' COLORS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY AND ARE NOT 2.
3.
ROOM NAMESROOM NOS
INTERIOR FINISH SCHEDULE
FLOOR BASE WALLS CEILING
REMARKS
FINISH COLOR FINISH COLOR FINISH COLOR FINISH COLOR HEIGHT
SURFACE
ROOFING
FLASHING
FASCIA
SOFFIT
DOOR & FRAME
HANDRAIL
MATERIAL
STEEL
STEEL PIPE
COLOR
CHOCOLATE
COLOR NO.
20095
CHOCOLATE
CHOCOLATE
CHOCOLATE
CHOCOLATE
CHOCOLATE
20095
20095
20095
20095
20095
REMARKS
WALL EIFS
WALL CMU
BEAM/COL CONC
CONC
SAND-STONE
SAND-STONE
SAND-STONE
SAND-STONE
23617
23617
23617
23617
PROTECTED METAL
EXTERIOR COLOR SCHEDULE-1
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
MAT'L
EXST
MAT'L
NEW
MAT'L
EXST
MAT'L
NEW
MAT'L
EXST
MAT'L
NEW
MAT'L
NEW
MAT'L
EXST
USER AGENCY.
SELECTION OF INTERIOR PAINT AND FACTORY APPLIED COLORS SHALL BE APPROVED BY
SHALL BE WATERPROOF TYPE GWB.GWB FOR TOILETS, AND OTHER WET AREAS 4.
F.F.
ACST 2450
PAINT PT-1
FINISH SCHEDULE NOTES
STAIR WALLS
PROTECTED METAL
PROTECTED METAL
PROTECTED METAL
VCT ACST F.F. ACST-1VCB
ACST 2450PAINT PT-1VCT ACST F.F. ACST-1VCB
VCT GCWT
VCT GCWT
VCT GCWT
QT QT-1
F.F.
F.F.
A-20
ARCHITECTURAL
& FINISH SCHEDULE NOTES
INTERIOR, EXTERIOR FINISH SCHEDULE
VEST
JANITOR
PVCT
PVCT PVCT-1
PVCT-1
F.F.FCT FCT-1
F.F.FCT FCT-1
F.F.FCT FCT-1
F.F. GCWT-1GCWT GWB 2450GWB* PAINT PT-2
F.F. GCWT-1GCWT GWB 2450GWB* PAINT PT-2
F.F. GCWT-1GCWT GWB 2450GWB* PAINT PT-2 GWB* : WATERPROOF TYPE
VCB F.F. VCB-1
VCB F.F. VCB-1
VCT
STORAGE
3150EPOXY COATING EP-1 VCB F.F. VCB-1VCB-
GWB GWB
W.TOILET/SHOWER
M.TOILET/SHOWER
GWB* : FIRE RESISTANT TYPE
GWB* : WATERPROOF TYPE
PAINT PT-1GWBQTB F.F. QTB-1 PAINT PT-2
OFFICE GWB GWB
CONFERENCE RM103
VCB
GWB GWB
CMU -- - GWBCONC* CONC* CONC* : SCP ON CONC WALL & CEILING107
108 3150EPOXY COATING EP-1 VCB F.F. VCB-1VCB GWB GWBCONC* CONC* CONC* : SCP ON CONC WALL & CEILINGCOMM ROOM PAINT PT-1 PAINT PT-2
VCT
3150VCB F.F. VCB-1VCB GWB GWBCONC* CONC* CONC* : SCP ON CONC WALL & CEILINGPAINT PT-1 PAINT PT-2VCT
111 MUD ROOM
VCT F.F. - - - - F.F. GCWT-1GCWT GWB 2450GWB* PAINT PT-2 GWB* : WATERPROOF TYPE
F.F.PVCT PVCT-1
MECH/ELEC ROOM
EYE WASHER RM
EPOXY EP-1
LAB
LOCKER ROOM
READY/WAITING/
GWB
GWB
VCT F.F.EPOXY EP-1 - - - -
VCT F.F.EPOXY EP-1 - - - -
F.F. GCWT-1GCWT GWB 2450GWB* PAINT PT-2 GWB* : WATERPROOF TYPEGWB
F.F. GCWT-1GCWT GWB 2450GWB* PAINT PT-2GWB
ACST 2450VCT ACST F.F. ACST-1VCBF.F.PVCT PVCT-1 VCB F.F. VCB-1 GWB GWB/GCWT PAINT/F.F.
GCWT-2*
PT-1/ GCWT-2* : KITCHEN CABINET WALL ONLY
GWB* : FIRE RESISTANT TYPE
F.F. 2600QT QT-1VEST VCT GWB GWBPAINT PT-1GWBQTB F.F. QTB-1 PAINT PT-2VCB GWB110
CORRIDOR116 F.F. ACST 2450PAINT PT-1GWBVCT VCB F.F. VCB-1 GWB ACST F.F. ACST-1PVCT PVCT-1 VCB
ACST 2450PAINT PT-1VCT ACST F.F. ACST-1VCBF.F.PVCT PVCT-1 VCB F.F. VCB-1OFFICE GWB GWB115
A-21
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
BASE MATERIAL/COLOR
M A T E R I A L & C O L O R S C H E D U L E
HANKOOK BLIND
MB-1
K-2, 25MM
VENETIAN ALUMINUM
OR APPROVED EQUAL
TP-1
STAINLESS STEEL,
SATINE FINISH
OR APPROVED EQUAL
FLOOR MATERIAL/COLOR
PVCT-1
FCT-1
OR APPROVED EQUAL
NON-SLIP, 300 x 300 x 8 THK
GGI 2984 OA, NON GLOSS
DONGSEO, INUS
FLOOR CERAMIC TILE
CEILING MATERIAL/COLOR
VCB-1
PT-2
EP-1
ABRASIVE GRAIN FINISH
OR APPROVED EQUAL
OR APPROVED EQUAL
DARK BROWN, 100 HGT, 3THK
LG HAUSYS
VINYL COVE BASE
CLEANPOXY 3100
NOROO PAINT & CO
EPOXY PAINT
WALL MATERIAL/COLOR
GCWT-1
: MOLD & MILDEW RESISTANT, STAIN PROOF
ANTIQUE WHITE
OR APPROVED EQUAL
* EPOXY GROUT COLOR FOR GCWT AND FT
OR APPROVED EQUAL
300 x 600 x 10 THK
FIELD TILE, DQL 2016 OA, GLOSS
DONGSEO, INUS
GLAZED CERAMIC WALL TILE
ACST-1
BB-1
MISC MATERIAL/COLOR
MINI BLIND
TOILET PARTITION & URINAL SCREEN
PS-1
OR APPROVED EQUAL
3048(W) X 2134(H)
W/PROJECTOR BRACKET
DRAPER, ENVOY, ELEC OPERATION
PROJECTION SCREEN FOR CONFERENCE ROOM
ACOUSTICAL TILE
ALUMINUM
ACOUSTICAL WALL PANEL
CEILING
COLOR
CONCRETE MASONRY UNIT
CONCRETE
COMMUNICATION
CARPET
CERAMIC WALL TILE
EXTERIOR INSULATION &
FINISH SYSTEM
ELECTRICAL
EXISTING
FLOOR TILE
FINISH
GYPSUM WALL BOARD
HEIGHT
MEN
MATERIAL
MECHANICAL
PAINT
REPAIR BY REPLACING
SKIM COAT PLASTER
VARIOUS
VINYL COVE BASE
VINYL COMPOSITION TILE
VINYL SHEET FLOORING
WOMEN
WOOD BASE
WOOD
ACST
AL
AWP
CLG
CLR
CMU
CONC
COMM
CPT
CWT
EIFS
ELEC
EXST
FT
FNSH
GWB
HGT
M
MATL
MECH
RBR
SCP
VAR
VCB
VCT
VSF
W
WB WD
A B B R E V I A T I O N
PT
ARCHITECTURAL
MATERIAL & COLOR SCHEDULE
PM-1
OR APPROVED EQUAL
PROJECTOR UNIVERSAL MOUNT
QT-1
QUARRY TEXTURES
#OT05, ADOBE BROWN
OR APPROVED EQUAL
QUARRY TILE BASE
DAL TILE
PT-1
SCP
QT-1 QUARRY TILE
QUARRY TEXTURES
#OT05, ADOBE BROWN
OR APPROVED EQUAL
DAL TILE, 152X152X12THK
OR APPROVED EQUAL
MARBLE, 457.2MMx457.2MM, 3MM THK
KCC SENSE TILE, CERAMIC, TS 55169,
PVC TILE
WD
PRL
LINER PANEL
PROTECTED METAL ROOF
OR APPROVED EQUAL
LATEX
EX8816-SNOWWHITE
ANTI-MOLD & MILDEW
KCC SUPRO HOME & WELLBEING
PAINT COLOR
OR APPROVED EQUAL
MT 410, WHITE
"KCC MITONE"
603MM x 603MM x 15MM THK
ACOUSTICAL CEILING TILE
OR APPROVED EQUAL
EX8816-IVORY
KCC SUPRO HOME AND WELLBEING
LATEX, INTERIOR
ANTI-MOLD AND MILDEW
PAINT
LK-1 LOCKER
IDES I & F INC. www.ides.co.kr
600W x 750D x 1800H x 100H base, HARDWARE / 1-COAT ROD, 2-COAT HOOK
LOCKER DOORS; 18THK ANSI 208.2 GRADE
MDF CORE WITH BLACK GLOSSY
PLASTIC LAMINATE FINISH,
MELATONE #7554E
LOCKER BOX ; 18THK ANSI 208.1 GRADE
PARTICLEBOARD CORE WITH BLACK
MELAMINE FINISH (COLOR : WHITE BEIGE)
& LOCK SET W/ RECESS HANDLE
OR APPROVED EQUAL
TWO TIER LOCKER
TOP 3EA ROBE HOOKS AND BOTTOM SHLEVE
GCWT-2
OR APPROVED EQUAL
300 x 600 x 10 THK
SQA2071, GLOSS
DONGSEO, INUS
GLAZED CERAMIC WALL TILE
TV-1
OR APPROVED EQUAL
WALL TYPE
UNIVERSAL TV MOUNT
SSM-1
OR APPROVED EQUAL
MELATON, 1157EA
PLASTIC LAMINATED SHEET
OR APPROVED EQUAL
MELATON, 3357EA
PLASTIC LAMINATED SHEET
PL-1
PL-2
OR APPROVED EQUAL
CRYSTAL PACIFIC, #NP932
LOTTE STARON MFG,
SOLID SURFACE MATERIAL
OR APPROVED EQUAL
BASE COAT-2MM, FINISH COAT-1MM
SMOOTH FINISH
BOOLIM POWTEC, S-301, GRAY
SKIM COAT OF PLASTER
OR APPROVED EQUAL
SIZE - 1800(W) x 900(H)
W/ 50x50 WIDE NATURAL OAK FRAME, ON 9 THK FIBER BOARD
10 THK NATURAL CORK BOARD
(WWW.THE-MOON.CO.KR),
THE MOON CO
BULLETIN BOARD
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
REMARKS
DOOR DIMENSION
WIDTH
MATERIAL
D1 A
DOOR
TYPE
DOOR
NOS.
ROUGH OPENING
WIDTH HEIGHT
HDW
SET
THICKHEIGHT NO (HR)
RATED
FIRE
LOUVERGLAZING
CUT
UNDER
FRAME
D2
D3
D4
D
D5
B - -
D6
D7
D8
DOOR
2133900 - -1
STEEL 44.5 - -2
44.5 -7
DOOR / WINDOW / LOUVER SCHEDULE DOOR/ WINDOW / LOUVER ELEVATIONS
2133STEEL
2133900
STEEL
44.521331000 2200 900STEEL
W/ INSECT /BIRD SCREEN
AND FRAME
FIXED AL LOUVER (45° BLADES)
D9
AL AL -
AA
(THERMAL BREAK TYPE)
W/ INSULATED GLASS
FRAME
ANODIZED AL DOOR &
J
AL LOUVER
D11
D12
D13
B
1000 2200 900
& STL FRAME
STL DOOR
THERMAL INSULATED C
& STL FRAME
STL DOOR
THERMAL INSULATED
G
FACTORY FINISH
(OAK, NATURAL VARNISH)
& STL FRAME
WOOD SOLID CORE DOOR
G STEEL -102133WOOD --44.51000 2200 900
INSULATED AL BLAST SLIDING WINDOW
(ANODIZED DARK BRONZE)
W/INSECT SCREEN
(THERMAL BREAK TYPE)
-PEAK REFLECTED PRESSURE
: 40.6 KPA
-PEAK IMPULSE
: 210 KPA - MS
( SHGC : MAX 0.4 )
+ 6 THK TINTED LOW-E TEMPERED GLASS
+ 12 THK AIR SPACE
8.75 THK CLEAR LAMINATED GLASS
H
D10
D14
F
A-22
ARCHITECTURAL
AND DETAIL
DOOR / WINDOW SCHEDULE, ELEVATIONS
E -
D15
D16
12001800ALGLASSH - -------W1 VERIFY BY BLAST WINDOW MFR
E
J AL 400AL 500 - - - - - - - -L1
: 40.6 KPA
- PEAK IMPULSE
: 210 KPA-MS
PRESSURE
- PEAK REFLECTED
844.5213322001000 900
DOOR W/ METAL FRAME
METAL BLAST RESISTANT
THERMAL INSULATED
: 40.6 KPA
- PEAK IMPULSE
: 210 KPA-MS
PRESSURE
- PEAK REFLECTED
* SOUNDPROOF DOOR, STC-25
(2 EA)
P L A N
DOOR
S E C T I O N
STEEL TUBE
CONC STOOP
WELDED TO
STEEL PLATE
50 x 50 x 6THK
FOUNDATION
STEEL PLATE
STEEL TUBE
CONCRETE
170 x 170 x 6THK
WELDED TO
EYEBOLT
HOOK &
DOOR
HOOK & EYEBOLT
STEEL TUBE
CONC)
GALV STEEL
80x80x3.2 THK
50 x 50 x 6 THK STEEL
80x80x3.2 THK
WALL TYPE BUMPER L02101
GALV STEEL TUBE
(FILLED W/CONC)
PLATE WELDED TO
WALL TYPE BUMPER L02101
YELLOW STRIPS
BLACK BACKGROUND
TUBE (FILLED W/
1 DOOR STOP & HOLDER DETAILS
250X250
SCHEDULE
PANEL AS
GLASS VISION
C STEEL 44.5 - -3 -2133STEEL 1900 2200 1800 -
G 44.5 -9 -STEEL 21331000 2200 900 --
G 44.5STEEL 21331000 2200 900 - 19-
1)
LAMINATED GLASS
SCHEDULE
PANEL AS
GLASS VISION
LAMINATED GLASS
1)
1) INSULATION LAMINATED GLASS
& AL FRAME
W/ INSULATED BLAST GLASS
(THERMAL BREAK TYPE)
(ANODIZED DARK BRONZE)
ANODIZED AL BLAST DOOR
INSULATED BLAST GLASS
(OUTER PANE)
(SEE NOTE)
D O
O R S
IZ
E
B
1) VERIFY BY BLAST DOOR MFR
D
& STL FRAME
STL HOLLOW CORE DOOR
1000 2200
E - -5STEEL 44.521331000 2200 900STEEL -
B - -6STEEL 44.521331000 2200 900STEEL --
E - -5STEEL 44.521331000 2200 900STEEL -
AL AL 1) 1) -
STEELSTEEL
1)
WOOD
G STEEL -112133WOOD --44.51000 2200 900
1)
WOOD
G 44.5STEEL 2133900 2200 800 - 19- -13WOOD
F - -14STEEL 44.52133900 2200 800STEEL -
F - -14STEEL 44.521331000 2200 900STEEL -
3/4
3/4
10001200ALGLASSH - -------W2 VERIFY BY BLAST WINDOW MFR
800900ALGLASSH - -------W3 VERIFY BY BLAST WINDOW MFR
100x600
100x600
100x600
100x600
1) VERIFY BY BLAST DOOR MFR
1) LAMINATED GLASS
1) LAMINATED GLASS
1)
100x600
1)
100x600
1) VERIFY BY BLAST DOOR MFR
1) VERIFY BY BLAST DOOR MFR
LAMINATED GLASS
(INNER PANE)
A-23
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
HARDWARE SCHEDULE
HDW-2
HDW-4
HDW-5
HDW-6
HDW-9
HDW-8
HDW-12
KEY BOX : WALL MOUNTED KEY BOX E83513.
COORDINATING WITH THE USER FOR APPROVAL BY COR.
THE CONTRACTOR SHALL SUBMIT MASTER KEYING CHART, 4.
5.
6.
8.
9.
7.
HEAT GAIN AND FIRERATED.
WHITE OR LIGHT BEIGE TO MAXIMIZE REFLECTANCE AND MINIMIZE
BE EQUIPPED WITH HORIZONTAL MINI BLINDS. COLOR SHALL BE
WINDOWS IN ALL AREAS WHERE FUNCTIONALLY WARRANTED SHALL
1.
2.
INSECT SCREEN SHOULD BE EQUIPPED TO ALL EXTERIOR WINDOWS.
NATURAL COLOR FINISH W/ QUARTER SLICED OAK.
ALL WOOD FLUSH DOORS SHALL BE FINISHED FACTORY COATED
10.
HIGH QUALITY AND GRADE PRODUCTS WITH APPROVAL TO COR.
& QUALITY ARE NOT REQUIRED. BUT CONTRACTOR SHOULD INSTALL
AN EXACT MATCH OF THE MANUFACTURERS FUNCTION, GRADE, COLOR,
AND ARE NOT INTENDED TO LIMIT SELECTIONS OF PRODUCTS.
MANUFACTURERS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY
( SHGC : MAX 0.4 )
+ 6 THK TINTED LOW-E TEMPERED GLASS
+ 12 THK AIR SPACE
: 8.75 THK CLEAR LAMINATED GLASS
TYPICAL INSULATED/LAMINATED GLASS FOR WINDOWS
BLAST AL DOOR & WINDOW GLASS SHALL BE PROVIDED BY MFR PER SPEC. 11.
DOOR & WINDOW NOTES
HDW-7
ARCHITECTURAL
THRESHOLD J32100
KICK PLATE J102, SST
CLOSER C02021
(W/ LEVER HANDLE)
LOCKSET 4000-1, F86
HINGES A5111, 114x114
1 DOOR STOP & HOLDER
HDW-10
HINGES A5112 114x114
DOOR STOP LO21611
1 PUSH PLATE J301
1 DOOR CLOSER C02011
1 PULL PLATE J405
KICK PLATE J102, SST1
MARBLE THRESHOLD1
& DOOR / WINDOW NOTE
HARDWARE SCHEDULE
CONTRACTING OFFICER BEFORE FABRICATION AND INSTALLATION
AS ACTUAL SIZE, AND DRAWINGS SHALL BE APPROVED BY THE
SHALL PREPARE SHOP DRAWINGS FOR ALL DOORS AND ALL WINDOWS
OR NEW WALL SHOULD NOT BE EXCEEDED 15MM. THE CONTRACTOR
GAP BETWEEN NEW DOOR OR NEW WINDOW FRAME AND EXISTING WALL
- WDMA TM-8 HINGE LOADING TEST METHOD
- WDMA TM-7 CYCLE SLAM TEST METHOD
2014 O&MA…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .