TELEPHONE OUTLET
BLANK WITH COVER
(TYPE ; RJ-45)
LAN (COMPUTER) SYSTEM OUTLET,
- E16
D-2
N O T T O S C A L E
COMMUNICATION OUTLET DETAIL
WITH A UNIQUE IDENTIFIER CODE. LABELING SHALL BE A MINIMUM OF 6MM HIGH.
ALL OUTLETS AND PATCH PANEL POSITIONS SHALL BE LABELED AS TO THEIR FUNCTION AND
1.
NOTES FOR COMMUNICATION SYSTEM
LUG TYPE OUTLETS SHALL BE INSTALLED ON THE APPROXIMATED 1200MM HEIGHT FROM FLOOR.
ALL CABLE TRAY ARE GRID PATTERN ED, COMPOSED OF MIN. 0.187" THK COLD ROLL STEEL.
POWER SUM EQUAL-LEVEL FAR-END CROSSTALK(PSELFEXT), RETURN LOSS, PROPAGATION DELAY AND DELAY SKEW
- WIRE MAP, LENGTH, INSERTION LOSS, NEAR-END CROSSTALK(NEXT) LOSS, POWER SUM NEAR-END CROSSTALK (ELFEXT), THE CONTRACTOR SHALL SUBMIT TEST REPORT TO COR INCLUDE BELOW.
7. THE RANGE OF TEST SHALL BE FROM MAIN DISTRIBUTION FRAME IN SIGNAL FACILITY TO NEW TELECOMMUNICATION ROOM.
2.
3.
4.
5.
6.
8. ALL COMMUNICATIONS WORK EFFORTS WILL BE IN ACCORDANCE WITH I3A STANDARD.
THE UL LISTED TWO HOLE LUG SHALL BE USED FOR ALL TERMINAL WORK OF TMGB.
SHALL BE SHOWN IN THE SHOP DRAWING SUBMITTAL.
THE CONTRACTOR SHALL SUBMIT THE DETAILED SHOP DRAWINGS. THE WIRING AND FINAL DEVICE ADDRESS
THE WIRING PLAN AND DIAGRAM OF COMMUNICATION SYSTEM IS CONCEPTUAL FOR IGCE PURPOSE ONLY.
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
HS-00557-7J D - 19 - 17
29 JUL 19
CAMP CARROLL
KIM, CK
E-16
- E16
D-1
SCALE : NONE
COMMUNICATION SYSTEM DIAGRAM - 3RD FLOOR
G
G
3M LENTH MIN
SERVICE LOOP,
FIBER OPTIC CABLE
EXISTING 1-12 STRAND SINGLE MODE
NEW 1-50PAIR, #24AWG TEL CABLE
DEDICATED CIRCUIT OF "LT-3" (TYP. OF 1EA)
2P-3W-125V-20A, GROUNDING TYPE WITH
NEW SURGE SUPPRESSION TYPE DUPLEX RECEPTACLE,
2100MM H X 475MM W
FLOOR MOUNTED RACK,
PATCH PANEL W/6-PIN MOD CONNECTORS
NEW 6EA-24PORTS RACK MOUNTED, CAT 6
CAT 6 PATCH CORDS, 105EA
PORTS AS REQUIRED (GFM)
FIBER OPTIC SWITCH, NUMBER OF
FIBER OPTIC PATCH CORD, 1-SINGLE MODE
PRODUCED PIG TAIL
INCL. FUSION SPLICE FACTORY
12 PORTS, RACK MOUNTED TYPE,
NEW FIBER OPTIC DISTRIBUTION FRAME,
NEW CAT 6 PATCH CORDS, 48EA
VOICE PATCH PANEL, CAT-6
NEW 6EA-24PORTS RACK MOUNTED
WITH DEDICATED CIRCUIT OF "LT-3" (TYP. OF 1EA)
MIN 6 RECEPTACLES, 2P-3W-125V-20A, GROUNDING TYPE
NEW RACK MOUNTED OUTLETS, SURGE SUPPRESSION TYPE
(480mm(W) X 13mm(T) X 50mm(L)
GROUNDING BUSBAR (TMGB)
NEW TELECOMMUNICATION MAIN
NEW CABLE TRAY 200MM W X 100MM H (TYPICAL)
COM. RM
FLOOR
FROM 1ST
(TYP. OF 1EA AND 4EA)
110 TYPE TERMINAL BLOCK
NEW 50PAIR BACKBOARD MOUNTED
NEW CAT 6 PATCH CORDS, 48EA
NEW GROUNDING WIRE,1-#3/ 0 AWG "BC"
NEW GROUNDING WIRE, 1-#6 AWG "BC"
WITH QUAD COVER PLATE (TYP. OF 102EA)
CAT-6, 8-PIN (RJ45 TYPE)
NEW DUAL MODULAR JACK
L
L
L
L
CAT 6, 4PAIR, #24AWG (TYP. OF 204EA)
- 3RD FLOOR AND OUTLET DETAIL
COMMUNICATION SYSTEM DIAGRAM
IN COMM. RM (TYPICAL)
PANEL ON COMMUNICATION RACK
WIRE TO CONNECTED TO PATCH
NEW 2W - CAT-6, 4PAIR, #24AWG IN 27MM RMC
FIRE RATED PLYWOOD 2EA
1200MM W X 2400MM H X 20MM THK,
NEW TELEPHONE TERMINAL BOARD(TTB)
(2-1 ADA, HQ)
REPAIR BUILDING NO. S-230
HS-00554-5J
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
D - 19 - 17
29 JUL 19
E-17
CAMP CARROLL
KIM, CK
SCALE : 1 /100- E17
P-1 FIRE ALARM PLAN - 1ST FLOOR
FIRE ALARM PLAN - 1ST FLOOR
UP UP
UP
122123124125126127
129 130 131 132 133 134 135 136
VELVE
120A
120B
114 113 112 111
109108107106105104
ELEC
MECH
COMM
’L1A’ ’L1B’
’MDP’
F
FMCPFTR
S
NOTIFICATION CONTROL PANEL
COMBINED FIRE ALARM/ MASS
DETECTOR(TYPICAL)
NEW ADDRESSABLE SMOKE
F
F
F
F
F
F
F
WP
F
F
WP
F
WP
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F F
F
F
F
F F
COAXIAL CABLE IN 16mmC
CONDUIT RISE TO 3RD FL.
W/CHARGER, NEMA 1 ENCL.
BUILDING TRANSMITTER W/BATTERY
FFFF
MT
S
MP
S
MT
S
MF
S
MT
S
LA
MANUAL PULL STATION,
ADDRESSABLE FIRE ALARM
SIGNAL STROBE(CANDELA AS REQ’D)
NEW COMBO(FA+MNS) AUDIO/VISUAL
"WP" TYPE
SIGNAL STROBE(CANDELA AS REQ’D)
NEW COMBO(FA+MNS) AUDIO/VISUAL
WP
IN NEMA 3R ENCL.
LIGHTNING ARRESTER KIT
1-#6 AWG (G) IN 16mmC
19mmDIA X 3000mmLG(TYPICAL)
GROUND ROD COPPER CLAD STEEL
AND DOWN STAIRS
CONDUIT UP & DOWN TO UPSTAIRS
ADDITIONAL LEGEND(THIS SHEET ONLY)
FMCP
FTR
W/CHARGER, NEMA 1 ENCL.
BUILDING TRANSMITTER W/BATTERY
M
M
M
MICROPHONE, NEMA 1 ENCL.
W/AMPLIFIER & BACK UP AMPLIFIER(AS REQ’D) &
MODULES PANLE(AS REQ’D) AND DIGITAL VOICE PANEL
MODULE, MICROPHONE, BATTERY W/ CHARGER, POWER
CONTROL MODULE, POWER SUPPLY, DIGITAL VOICE
& RELAYS, LCD ANNUCIATOR, SYNCHRONIZATION
POINT MODULES AS REQ’D, PROGRAMMABLE MODULE
CONTROL PANEL, 24VDC, BUILT-IN ADDRESSABLE
COMBINED FIRE ALARM/ MASS NOTIFICATION
MODULE(UNDER MECH ITEM)
PRESSURE SWTICH W/ ADDRESSABLE
MODULE(UNDER MECH ITEM)
FLOW SWTICH W/ ADDRESSABLE
MODULE(UNDER MECH ITEM)
TAMPER SWTICH W/ ADDRESSABLE
PS
TS
FS
INSTALLED IN A MANNER THAT PROVIDES VISUALLY AND ACCESS FOR TESTING AND PERIODIC MAINTENANCE.
ALL FIRE ALARM INITIATING DEVICE SUCH AS SMOKE DETECTOR AND MANUAL PULL STATIONS SHALL BE
SHALL BE CONCEALED, BUT MAY BE EXPOSED WHERE NOT POSSIBLE.
ALL CONDUITS TO FIRE ALARM CONTROL PANEL SHALL BE RUN INTO THE SIDE OF THE PANEL WIRING
MATERIAL.
TO VERIFY COMPLIANCE WITH STANDARDS. CONTACT FIRE PREVENTION OFFICE TO COORDINATE INSPECTION OF
ALL DEVICES AND EQUIPMENT MUST BE INSPECTED BY THE FIRE PREVENTION OFFICE PRIOR TO INSTALLATION
NOTES FOR FIRE ALARM SYSTEM
3.
SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL.
BE PREPARED IN THE FIELD BY THE CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND
SOME DETAILS SHOWN ON THIS DRAWINGS MAY NOT MATCH EXACT FIELD CONDITIONS. SUCH DETAILS SHALL
9.
STANDARD.
AND MUST PROVIDE A LETTER STATING THAT THE SYSTEM IS INSTALLED IAW NICET STANDARDS AND NFPA
NICET CERTIFIED PERSON MUST BE ON SITE INSTALLING OR SUPERVISING INSTALLATION OF THE SYSTEM
MINIMUM NICET LEVEL III CERTIFICATION IS REQUIRED FOR ALL FIRE ALARM SYSTEM INSTALLATION.
2.
4.
7.
8.
6.
5.
OF 1’-6" AND ANY AIR SUPPLY DIFFUSER OR RETURN AIR OPENING A MINIMUM DISTANCE OF 3’.
FIRE ALARM DETECTORS SHALL BE LOCATED TO CLEAR ANY LIGHTING FIXTURE A MINIMUM DISTANCE
FOR FIRE ALARM SYSTEM SHOULD BE LOCATED IN ACCORDANCE WITH NFPA 72.
FIRE ALARM DEVICES INCLUDING INITIATING DEVICES, NOTIFICATION DEVICES AND ALL OTHER EQUIPMENT
1.
OF MANUFACTURER
IN RIGID METAL CONDUIT AND NUMBER AND SPECIFY OF WIRE/CABLE IS FOLLOWED AS DESIGNATION
FIRE ALARM CIRCUIT SHALL BE DOUBLE LOOP SYSTEM IN A SEPARATE CONDUIT AND ANY CIRCUIT
TO COMMENCING ANY CONSTRUCTION OR RENOVATION.
THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFY ALL EXISTING CONDITION AND DIMENSIONS PRIOR
THE WIRING AND FINAL DEVICE ADDRESS SHALL BE SHOWN IN THE SHOP DRAWING SUBMITTAL.
TECHNICAL REVIEW BRANCH AND FIRE PREVENTION OFFICE FOR APPROVAL PRIOR TO CONSTRUCTION.
THE CONTRACTOR SHALL SUBMIT THE DETAILED SHOP DRAWINGS AND DESIGN ANALYSIS TO THE
APPLICABLE CODES AND REGULATION TO COMPLETE SUBJECT PROJECT CONSTRUCTION.
COST CAUSE FROM NOT SHOWN OR/AND INDICATED IN THE CONCEPTUAL DRAWINGS TO MEET WITH
ARE CONCEPTUAL FOR IGCE PURPOSE ONLY. THE CONTRACTOR IS RESPONSIBLE FOR ALL OTHER ADDITIONAL
THE WIRING PLAN AND DIAGRAM OF FIRE ALARM AND MASS NOTIFICATION SYSTEM SHOWN ON DRAWINGS
10.MASS NOTIFICATION ANNUNCIATION DEVICES SHALL BE MARKED "ALERT". STROBES SHALL BE YELLOW.
(2-1 ADA, HQ)
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
D - 19 - 17
E-18
CAMP CARROLL
29 JUL 19
KIM, CK
SCALE : 1 /100- E18
P-1
SCALE : 1 /100- E18
P-2
FIRE ALARM PLAN - 2ND FLOOR
FIRE ALARM PLAN - 3RD FLOOR
AND 3RD FLOOR
FIRE ALARM PLAN - 2ND FLOOR
219218 224223222221220
207A
207B
209B
209C
210A 209A
210B
210C211B212
211A
213214A
214B215B
215C 214C
216A 215A
216C
216B
COMM
UP DN UPDN
DN UP
F
F
F
FFF
F
FFFFFFF
F
F
FF
F
F
FFFF F
FF
FF
F F
F F FF
M
TS
M
FF
F
FMPS
AND DOWN STAIRS
CONDUIT UP & DOWN TO UPSTAIRS
FS
SIGNAL STROBE(CANDELA AS REQ’D)
NEW COMBO(FA+MNS) AUDIO/VISUAL
MANUAL PULL STATION,
ADDRESSABLE FIRE ALARM
314 313 312
311D
311E
311A
311C
311B
310 308A
309 308B
319B
319C
316A
316B
319A
304A
305B
304B
305A
307C
307A
307BCOMM
DN DN
DN
FF
F
F
F
FF
F
FFF
F
FF F
F
F
F
F
F
F
F
F
F
F F
F
FFFF
TYPE W/MOUNTING BRACKET
FIRE ALARM ANTENNA OMMI-DIRECTION
F
F FFMPS
CONDUIT DOWN TO DOWNSTAIR
M
TS
M
FS
(2-1 ADA, HQ)
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
D - 19 - 17
E-19
CAMP CARROLL
29 JUL 19
KIM, CK
AND NOTES
FIRE ALARM SINGLE LINE DIAGRAM
- E19
S-1 FIRE ALARM SINGLE LINE DIAGRAM
SCALE : NONE
FMM
G
E
2-#12 AWG & 1-#12(G) IN 16mm C.
W/BATTERY & BATTERY CHARGER
BUILDING TRANSCEIVER
L.A
1-#6 AWG(G) IN 21 mmC
IN 21 mmC
ANTENNA COAXIAL CABLE
(TYPICAL)
GROUND ROD SEE SPEC.
MANUAL PULL STATION
ADDRESSABLE FIRE ALARM
SEE FIRE/ MNS PLAN
AND AUX. RELAY. NEMA 1, ENCL.
W/BATTERY, BATTERY CHARGER 24VDC
MODULES AS REQUIRED, AMPLIFIER
24VDC BUILT-IN ADDRESSABLE POINTS
(TYP. OF 2EA)
FIRE/MNS POWER SUPPLY PANEL
G
FMCP
3RD FL.
2ND FL.
FMPS-2
BT-XME
C
FN
F FFF FF
F
F F F F F F F F F F F
307A
FFFFFFFF
FFFFF
319A
FFFFFFF
FMMF FFF FF
F
F F F F F F F F
209C
FFFFFF
FFFFF
FFFFFFF
TO PANELBOARD "MDP-10"(1PH 120VAC)
1ST FL.
TSFS
TSFS
2-#12 AWG & 1-#12(G) IN 16mmC
TO PNL."LP-15"
2-#12 AWG & 1-#12(G) IN 16mmC
TO PNL."LP-15"
FMPS-1
F
FN
F
FFFM M M M M
PS
F
TS TS FS TS
FFFFF
F F F F F F F FF
FFF
AND AUX. RELAY IN RM. 101 NEMA 1, ENCL.
BATTERY, BATTERY CHARGER 24VDC
AMPLIFIER SELECTABLE ALARM VERIFICATION.
W/VOICE EVACUATION SYSTEM,
MODULES AS REQUIRED
24VDC BUILT-IN ADDRESSABLE POINTS
ALARM CONTROL PANEL
SURFACE MTD TYPE. ADDRESSABLE FIRE
TYPE WITH MOUNTING BRACKET
FIRE ALARM ANTENNA OMNI-DIRECTION
COAXAL CABLE AND NEMA 3R ENCL.
LIGHTING ARRESTER KIT WITH
F
F F FFF FF FF F F F FFF FFF F
WP
103 102 104 105 106 107 108 109
F
WP
F F FFF FFF
WP
115 120A 101 118 114 113 101 111
F
F
F
122 101
134 135132 133130 131
WP
101 123125 124127 126
136 137
101138101 101
FF
N
N
NN
N N
NN
203 204 205 206 207B
F
207A
209B209A
F
201210B
FFF
210A209C201212211A
NN
223222221220219218
216A216C 216B 201 215A 215B 214B 214C 215C
F
F
214A
F
137 101137137137137
201201201 225225
301320320301 301
305A305B304B304A303
N
N
307B301307A307C301309308A
319C319B318317316B316A
314 313 301 312 311D 311E 311A 301 318B 311C 310
"WP" TYPE
SIGNAL STROBE(CANDELA AS REQ’D)
NEW COMBO(FA+MNS) AUDIO/VISUAL
SIGNAL STROBE(CANDELA AS REQ’D)
NEW COMBO(FA+MNS) AUDIO/VISUAL
SYSTEM #6, "BC" IN 21mmC(TYPICAL)
CONNECT TO BLDG ELECTRODE GROUNDING
3.
N
F
NOTES;
VOICE EVACUATION SYSTEM
LINE FROM POWER SUPPLY FOR
STROBE/SPEAKER POWER CONTROL
CONTROL PANEL
SIGNAL LINE CIRCUIT FROM FIRE/MNS
LEGEND, SEE DWG. E-01.
1. FOR ABBREVIATION, GENERAL NOTES &
NOTES, SEE DRAWING E-16-E-17.
2. FOR FIRE ALARM SYSTEM PLAN, LEGNED &
(2-1 ADA, HQ)
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
D - 19 - 17
CAMP CARROLL
29 JUL 19
KIM, CK
E-20
122123124125126127
129 130 131 132 133 134 135 136
VELVE
120A
120B
114 113 112 111
109A108107106105104
109B
ELEC
MECH
COMM
219218 224223222221220
204 206205
207A
207B
209B
209C
210A 209A
210B
210C211B212
211A
213214A
214B215B
216A
216C
216B
215A
215C 214C
COMM
SCALE : 1 /100- E20
P-1 CCTV, IDS PLAN - 1ST FLOOR
SCALE : 1 /100- E20
P-2 CCTV PLAN - 2ND FLOOR
C
C
C
C
C C
C
C
C
MS
A
MS
D
BMS INFTSK INFTSK BMS
D
MS
A
MSMS
MS
A
D
BMS TSK INF INFTSK BMS
D
MS
A
MSMS
A
MS
D
BMS TSK INF
IN ARMS ROOM (TYP. OF 5SET)
IDS (INTRUSION DETECTION SYSTEM)
REMOVE AND REINSTALL EXISTING
AND WIRING INCL BOXES (1ST, 2ND AND 3RD FLOOR)
-CONTROL BOX, INTERROR / EXTERIOR CAMERAS,
REMOVE AND REINSTALL EXISTING CCTV SYSTEM
AND 2ND FLOOR
CCTV, IDS PLAN - 1ST FLOOR
(2-1 ADA, HQ)
REPAIR BUILDING NO. S-230
UP UP
UP
UP DN UPDN
DN UP
WITH INSTALLATION KIT(TYP OF 10EA)
EXISTING CEILING MOUNTED MOTION DETECTOR
EXISTING INFRAGUARD SMART AUDIO SENSOR
MOUNTING BOX(TYP OF 5EA)
WITH KEYPAD DISPLAY AND ACT TSK DISPLAY
EXISTING INGRAGUARD PANEL, INFRAGUARD TOUCH SCREEN
DURESS INSTALLATION
EXISTING BUTTON KEY RESETABLE WITH KIT HAND
WITH INSTALLATION KIT(TYP OF 5EA)
EXISTING DOOR BALANCED MAGNETIC SWITCH
E-21
HGFEDCBA
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
D - 19 - 17
CAMP CARROLL
29 JUL 19
KIM, CK
DN DN
314 313 312
311D
311E
311A
311C
311B
310 308A
309 308B
319B
319C
318317
316A
316B
319A
303 304A
305B
304B
305A
307C
307A
307B
SCALE : 1 /100- E21
P-1 CCTV, SIRP NET PLAN - 3RD FLOOR
C
C C
CC
1.
NOTES FOR CCTV, IDS, SIRP NET SYSTEM
THE CONTRACTOR SHALL COORDINATE WITH AREA MP, PHYSICAL SECURITY AND SIGNAL BRIGADE BEFORE CONSTRUCTION.
AND WIRING INCL BOXES (1ST, 2ND AND 3RD FLOOR)
-CONTROL BOX, INTERROR / EXTERIOR CAMERAS,
REMOVE AND REINSTALL EXISTING CCTV SYSTEM
IN 3RD FLOOR
CONTRACTOR SHALL REMAIN EXISTING SIPR LINE
CCTV, SIRP NET PLAN - 3RD FLOOR
(2-1 ADA, HQ)
REPAIR BUILDING NO. S-230
COMM
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
D - 19 - 17
29 JUL 19
CAMP CARROLL
KIM, CK
E-22
ELECTRICAL POWER SINGLE LINE DIAGRAM
ELECTRICAL SITE PLAN AND
(2-1 ADA, HQ)
REPAIR BUILDING NO. S-230
- E22
P-1
SCALE : 1 /200
UPUP
ELEC
MECH
ELECTRICAL SITE PLAN
MECH. ROOM
G
GROUNDING BUSBAR
NEW TELECOMMUNICATION MAIN
"MDP"
"MD"
TMGB
WHM
G
N O T T O S C A L E
2,400 MM LG, W/CLAMP
CLAD STEEL, 19MM DIA X
NEW GROUND ROD, COPPER
IN 42 RMC
NEW 4-#3 AWG "THW" & 1-#8 AWG (G)
G
2,400 MM LG, W/CLAMP
CLAD STEEL, 19MM DIA X
NEW GROUND ROD, COPPER
CHILLER
ELEC.
T
IN 104MM RMC
3SET OF 4-400KCMIL "THW" & 1-#3 AWG (G)
NEW UNDERGROUND SERVICE LATERAL
OUTDOOR UNIT,
3EA-2 POSITION LBS, LOOP TYPE,
DELTA-WYE CONNECTION WITH
"T0-200-00", 3PH, 22.9KV-120/208V-400KVA,
NEW PAD MOUNTED TRANSFORMER,
NEW MAIN PANEL BOARD "MDP"
1-#2/ 0 AWG (G) IN 28mm RMC
NEW GROUNDING WIRE
IN 104MM RMC
3SET OF 4-400KCMIL "THW" & 1-#3 AWG (G)
NEW UNDERGROUND SERVICE LATERAL
NEMA 1 ENCL. WITH GROUDING WIRE CONNECTION
FOR REMOTE MONITORING, NO OF DIALS ON REGISTER: 4,
3PH-4W-208Y/120V CIRCUIT, AND COMMUNICATION OPTION
WITH 3EA CURRENT TRANSFORMERS(1000:5), FOR USE ON
NEW WATTHOUR METER, SELF-CONTAINED, 120VY, 2.5A,
NEMA 1 ENCL. WITH GROUDING WIRE CONNECTION
FOR REMOTE MONITORING, NO OF DIALS ON REGISTER: 4,
3PH-4W-208Y/120V CIRCUIT, AND COMMUNICATION OPTION
WITH 3EA CURRENT TRANSFORMERS(1000:5), FOR USE ON
NEW WATTHOUR METER, SELF-CONTAINED, 120VY, 2.5A,
IN 104MM RMC
NEW 3SET OF 4-400KCMIL "THW" & 1-#3 AWG (G)
MECH. ROOM
ELECT.. ROOM
INDOOR
OUTDOOR
"MH"
1-#3/ 0 AWG (G) IN 28mm RMC
NEW GROUNDING WIRE
IN 28MM RMC
NEW 4-#8 "THW" & 1-#10 AWG(G)
1-#4 AWG (G) IN 82MM RMC
NEW 2SET OF 4-250KCMIL "THW" &
G
G
GAS LINE AND WATER LINE
1-#1/ 0 AWG (G) IN 28MM RMC
NEW GROUNDING WIRE
1-#3/ 0 AWG "BC" IN 22MM RMC
NEW GROUNDING WIRE
"L1A" "L1B" "LT1"
"L2A" "L2B" "LT2"
"L3A" "L3B" "LT3"
IN 36MM RMC
NEW 4-#4 AWG "THW" & 1-#8 AWG (G)
FIRST FLOOR
THIRD FLOOR
SECOND FLOOR
- E22
S-1 ELECTRICAL POWER SINGLE LINE DIAGRAM
PRIMARY UNDERGROUND CABLE
EXISTING INCOMING AND OUTGOING
OUTDOOR UNIT,
3EA-2 POSITION LBS, LOOP TYPE,
DELTA-WYE CONNECTION WITH
"T0-200-00", 3PH, 22.9KV-120/208V-400KVA,
NEW PAD MOUNTED TRANSFORMER,
55.
TREE
CONTAINER
DESIGNED BY
CHECKED BY
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :SAFETY REP
SIGNAL REP
FES
FORCE PROTECTION
CHIEF,
DESIGN & TECH. REVIEW Br.
O & M
HOUSING DIV.
REVIEWED BY
SYMBOL BY CHK.ZONE DATE APVD.
R E V I S I O N S
DESCRIPTION
UNITED STATES ARMY GARRISON DAEGU
DIRECTORATE OF PUBLIC WORK
ENGINEERING DIVISION, DESIGN & TECHNICAL REVIEW Br
UNIT #15746, APO AP 96218-5746
DATE:
SIN, YS
SHEET OFAS SHOWN
ELECTRICAL
D - 19 - 17
29 JUL 19
CAMP CARROLL
KIM, CK
E-23
- E23
S-1
N O T T O S C A L E
PANEL SCHEDULE "L1A"
SURFACE MOUNT, NEMA 1 ENCL
3PH-4W-120/208V-60HZ, W/ SN & GRD, 10,000AIC
S N
GRD
BA
C N
PANEL BOARD "L1A" LOAD SCHEDULE
5 6
INDICATES A SHUNT-TRIP TYPE BRANCH CIRCUIT BREAKER.
INDICATES A BRANCH CIRCUIT BREAKER WITH HANDLE PADLOCK IN "ON" POSITION.
3P
80AT
SURFACE MOUNT, NEMA 1 ENCL
3PH-4W-120/208V-60HZ, W/ SN & GRD, 10,000AIC
S N
GRD
BA
C N
PANEL BOARD "L1B" LOAD SCHEDULE
5 6
3P
80AT
- E23
S-2
N O T T O S C A L E
PANEL SCHEDULE "L1B"
INDICATES A SHUNT-TRIP TYPE BRANCH CIRCUIT BREAKER.
INDICATES A BRANCH CIRCUIT BREAKER WITH HANDLE PADLOCK IN "ON" POSITION.
PANEL SCHEDULE "L1A" AND "L1B"
SPACE
SPACESPACE
(2-1 ADA, HQ)
REPAIR BUILDING NO. S-230
100AF 100AF