SCHEDULE OF DRAWINGS

RING NO. REF. NO.REVISION STATUSDWG. NO. SHT. NO.REF. NO.

T - 1

RING NO.

CIVIL

C - 1

M - 1

M - 2

M - 3

MECHANICAL

ELECTRICAL

A - 1

A - 2

A - 3

ARCHITECTURAL

DESCRIPTION OF DRAWINGS

TITLE SHEET

DWG. NO. SHT. NO. DESCRIPTION OF DRAWINGS REVISION STATUS

TITLE SHEET

T-1

A - 4

A - 5

A - 6

A - 7

A - 8

A - 9

M - 4

M - 5

M - 6

M - 7

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

C - 2

C - 3

LOCATION PLAN AND GENERAL NOTES

A - 10

A - 11

A - 12

E - 1

E - 2

E - 3

E - 4

E - 5

E - 6

E - 7

E - 8

E - 9

E - 10

E - 11

E - 12

E - 13

E - 14

M - 8

A - 13

A - 14

A - 15

A - 16

M - 11

M - 12

M - 13

M - 14

M - 15

M - 16

M - 17

M - 18

M - 19

M - 20

M - 21

M - 22

M - 23

M - 24

M - 25

LEGEND, GENERAL NOTES AND SCOPE OF WORK

SITE LAYOUT PLAN AND SCOPE OF WORK

A - 17

GENERAL NOTES & SCOPE OF WORK

DETAILS-1

DETAILS-2

DETAILS-3

DETAILS-4

1ST FLOOR PLAN-2 AND GENERAL NOTES

2ND FLOOR PLAN-1

3RD FLOOR PLAN-1

3RD FLOOR PLAN-2 AND DETAILS

GENERAL CROSS SECTION & DETAILS

WALL SECTIONS

MISC DETAILS-1

MISC DETAILS-2

CABINET DETAILS

SIGNAGES SCHEDULE

INTERIOR, EXTERIOR FINISH SCHEDULE AND MATERIAL & COLOR SCHEDULE

DOOR, WINDOW SCHEDULE AND HARDWARE SCHEDULE

DOOR, WINDOW ELEVATIONS, NOTES AND DETAILS

1ST FLOOR PLAN-1

C - 4 MISC. DETAILS-1

MISC. DETAILS-2

MECHANICAL EQUIPMENT SCHEDULE

CONTROL DIAGRAM

FIRE PROTECTION CLASSIFICATION PLAN (1ST & 2ND FLOOR)

2ND FLOOR FIRE PROTECTION PIPING PLAN

3RD FLOOR FIRE PROTECTION PIPING PLAN

MECHANICAL MATERIAL INDICATIONS & SYMBOLS AND ABBREVIATIONS

E - 15

E - 16

E - 17

E - 18

LIGHTING FIXTURE DETAILS

EXIST PANELBOARD CONN DIAGRAMS-2

NEW FIRE ALARM/MASS NOTIFICATION SYSTEM DIAGRAM

CONTROL DIAGRAM

LIGHTING FIXTURE SCHEDULE & NEW EXTERIOR LIGHTING

2ND FLOOR PLAN-2 AND SCOPE OF WORK

ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS-1

ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS-2

A - 18

2ND FLOOR HVAC PLAN AND NOTES

3RD FLOOR HVAC PLAN AND NOTES

SEWER PIPING PLAN (1ST & 2ND FLOOR) AND NOTES

SEWER PIPING PLAN (3RD FLOOR), ENLARGED PLAN AND NOTES

SUPPRESSION GENERAL NOTES AND SPRINKLER Q'TY LIST

FIRE PROTECTION LEGEND & ABBREVIATION AUTOMATIC FIRE

REQUIREMENTS

FIRE PROTECTION PIPING PARTIAL PLAN AND FIRE PROTECTION

FIRE PROTECTION CLASSIFICATION PLAN (3RD FLOOR), MECH ROOM

DETAILS-5

M - 26

M - 27

M - 9

M - 10

FIXTURE SCHEDULE, WATER HAMMER ARREST AND NOTES

COLD AND HOT WATER PIPING PLAN (3RD FLOOR), PLUMBING

SYSTEM, S-1974, CP CASEY

REPAIR BUILDING & INSTALL SPRINKLER

FEWR NO. 131420, CAMP CASEY

ENLARGED PLAN FOR TYPE "A", "B", "C" AND ENLARGED PLAN

NEW 1ST & 2ND FLOOR LIGHTING PLAN

NEW 3RD FLOOR LIGHTING PLAN & MODULE LIGHTING PLAN

NEW 1ST & 2ND FLOOR POWER PLAN

NEW 3RD FLOOR POWER PLAN & MODULE POWER PLAN

NEW 1ST & 2ND FLOOR FAN COIL UNIT POWER/CONTROL PLAN

NEW 3RD FLOOR FAN COIL UNIT POWER/CONTROL PLAN

EXIST PANELBOARD CONN DIAGRAMS-1

SYSTEM PLAN

NEW 1ST & 2ND FLOOR FIRE ALARM CONTROL/MASS NOTIFICATION

NEW 3RD FLOOR CATV/CCTV/TELEPHONE PLAN

CATV SYSTEM DIAGRAM

PLAN

NEW 3RD FLOOR FIRE ALARM CONTROL/MASS NOTIFICATION SYSTEM

C - 5

MISC. DETAILS-3C - 6

SYSTEM, S-1974, CP CASEY

REPAIR BUILDING AND INSTALL SPRINKLER

KWON, CH

131420

ELEVATIONS AND PICTURES

1ST FLOOR HVAC PLAN AND NOTES

MECHANICAL ROOM ENLARGED PLAN, ELEC. UNIT HEATER CONTROL AND NOTES

AND CO DETECTION SYSTEM

FAN COIL UNIT CONTROL DIAGRAM, MECH RM WALL FAN CONTROL DIAGRAM,

COLD AND HOT WATER PIPING PLAN (1ST & 2ND FLOOR) AND NOTES

CHILLED/HOT WATER PIPING SYSTEM DIAGRAM AND SEQUENCE OF OPERATION

SEWER AND VENT PIPING ENLARGED PAITIAL PLAN

1ST FLOOR FIRE PROTECTION PIPING PLAN

MECH ROOM, 2ND LAUNDRY ROOM ENLARGED PLAN

TELECOMMUNICATION SYSTEM DIAGRAM FOR 1ST FLOOR

NEW 1ST FLOOR LAN/TEL PLAN

NEW 1ST & 2ND FLOOR CATV/CCTV/TELEPHONE PLAN

E - 19

E - 20

BIKE SHED PLAN, SECTION & DETAILS