A-1
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
SCALE: 1 : 100
1ST FLOOR PLAN-1
KEY PLAN 1ST FLOOR PLAN-1
LEGEND
200 THK MET STUD WALL
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
KWON, CH
131420
D1
W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1
W1W1W1W1W1W1
UP
69,698
1,829
,6
,8
,6
,7
,1
,8
69,698
27,838
FEC
UP
FEC
1,829
137107108110
STORAGE
111112
115 116
125124
STAIR-2
STAIR-1
139138
MECH ROOM
VEST-2
VEST-1
OFFICE
SUPPLY ROOM
TEL/COMM ROOM
LOBBY
CORRIDOR-1 CORRIDOR-2
W. TOILET M. TOILET
BALCONY
BALCONY
D4D3
D8
D8
4,775 4,572 1,772 2,800 2,234 2,338 4,674 4,674 6,096 3,251 3,000 4,000 2,347 6,246
14,017
2,4292,346 4,572 4,572 4,572 1,624 3,050 4,669 4,678 4,669 4,674 4,674 4,678
200 THK CMU WALL W/EIFS
JANITOR
D8
D8
D8
D8
D8
D8
D8
D8
D8
D8 D13
D19
D13 D13D14 D14
D5
D13
FEC
CONFERENCE
D8
EOC
SEC VAULT
COMM/
OFFICE
OFFICE
WAR ROOM
D8
W1
D8
ROKA-2
S-3 OFFICES-6 OFFICE
OFFICE
CHAPLAIN
ASST OFFICE
CHAPLAIN
S-4 OFFICE
S-2 OFFICE
ROKA-1
FEC
150 MM METAL STUD CHASE WALL
W/SOUND PROOF INSULATION
200 OR 150 MM METAL STUD WALL
EXISTING EXTERIOR CMU WALL W/50MM STUD WALL
EXISTING INTERIOR CMU WALL W/50MM OR 90MM STUD WALL
150 MM METAL STUD WALL
D2
D21
L1
A-2
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
MANUFACTURES INDICATED.
PURPOSES ONLY. AND NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE
COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR BIDDING IDENTIFICATION 1.
ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER REPRESENTATIVE (COR).
CAUSED BY THIS PROJECT AND SHALL REPAIR THE DAMAGES TO MATCH UP TO
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES MADE TO EXISTING AREAS
FOR APPROVAL.
CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITION AND SUBMITED TO COR
CONDITION. IN THAT CASE, SHOP DRAWINGS SHALL BE PREPARED AT THE SITE BY THE
SOME DETAILS SHOWN ON CONTRACT DRAWINGS MAY NOT COINCIDE WITH THE FIELD
8.
FOR APPROVAL.
CONTRACTOR SHALL SUBMIT MANUFACTURER'S INSTALLATION SHOP DRAWINGS TO COR
2.
3.
4.
5.
6.
7.
CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER.
IF THERE ARE ANY CONFLICTS WITHIN THE CONTRACT DOCUMENT, THE GENERAL
AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.
THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION
OF THE LOAD BEARING WALLS TO PREVENT COLLAPSE OF THE STRUCTURE.
APPROPRIATE TEMPORARY SUPPORTS SHOULD BE CONSTRUCTED PRIOR TO DEMOLITION
9.
10.
11.
12.
13.
14.
DETAILS AND GET APPROVAL FROM COR. BEFORE FABRICATION AND INSTALLATION.
CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL DOOR/WINDOW
ADDITIONAL COST TO THE GOVERNMENT.
EQUIPMENT, ETC), ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM WITHOUT
THE INSTALLATION AND/OR REPLACEMENT OF MECHANICAL (PLUMBING, HEATING,
ITEMS, CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING WHERE REQUIRED FOR
THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVE/REINSTALL ANY OBSTRUCTED
GENERAL NOTES
SPECIFICATION 15181.
ITEMS REQUIRING MAINTENANCE/OPERATION IAW THE SECTION 3.1.14, OMA STD
PROVIDE ACCESS DOORS FOR ALL CONCEALED VALVES, VENTS, CONTROLS AND OTHER
COMMENCEMENT OF FLOOR TILE WORK AND AS PER FLOOR FINISH SCHEDULE.
ALL CONCRETE FLOOR SURFACES SHALL BE LEVELED AND SMOOTHED PRIOR TO
OFFICE, DPW. PER DIRECTION FROM THE INSPECTOR IN CHARGE OR COR.
SALVAGE OR SERVICEABLE MATERIALS SHALL BE RETURNED TO SUPPLY OR STORAGE
SHALL BE AS A PART OF THE CONTRACT DOCUMENT OF THIS PROJECT.
STANDARD DETAIL DRAWINGS FOR O&MA PROJECT, KOREA, DATED OCTOBER 1, 2003
1.67 K. SM/W
3.34 K. SM/W
WALL
ROOF : -
& COATING.
REMOVE & CLEAN EXISTING PAINT BY SAND PAPER/ GRINDING FOR NEW PAINTING
FROM THE MANUFACTURE SHOWING THE PRODUCT IS LEAD FREE.
A CERTIFICATE OR MATERIAL SAFETY DATA SHEET (MSDS), WRITTEN IN ENGLISH,
SOLIDS) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR WILL PROVIDE
COATINGS WITH LESS THAN 0.05 PERCENT LEAD BY WEIGHT OF THE NON-VOLATILE
THE CONTRACTOR IS REQUIRED TO USE "LEAD FREE" COATINGS (LIQUID PAINTS OR
15.
16.
17.
DOCUMENTATION TO 8 CES/CEAN.
THE CONTRACTOR SHALL PROVIDE THE NEW SURVEY REPORT AND ASBESTOS REMOVAL
ACCORDANCE WITH THE KOREA ENVIRONMENTAL GOVERNING STANDARD (KEGS).
PRIOR TO ANY WORK TO ASSURE THAT APPROPRIATE ASBESTOS CONTROL IS IN
AREA WILL NEED TO BE RESURVEYED AND ASBESTOS MATERIALS SHOULD BE REMOVED
WORK IN THE AFFECTED AREA AND NOTIFY THE CONTRACTING OFFICER. THE WORK
ASBESTOS CONTAINING MATERIAL ARE DISCOVERED, THE CONTRACTOR SHALL CEASE
IS NOT PRESENT IN THE AREAS AFFECTED BY THIS WORK: HOWEVER, IF SUSPECTED
VERIFYING THE PRODUCT IS ASBESTOS FREE. TESTS HAVE INDICATED THAT ASBESTOS
WILL PROVIDE A CERTIFICATE OR MSDS, WRITTEN IN ENGLISH, FROM THE MANUFACTURER
PERCENT BY WEIGHT) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR
THE CONTRACTOR IS REQUIRED TO USE "ASBESTOS FREE" MATERIALS (LESS THAN 0.1
SCALE: 1 : 100
1ST FLOOR PLAN-2
KEY PLAN 1ST FLOOR PLAN-2 AND GENERAL NOTES
W1 W1 W1 W1 W1
W1W1W1W1W1
27,843
,6
,8
,5
,5
,4
,9
,1
,8
UP
FEC
3,764
129127
OFFICE
COMMANDING
VEST-3
VAULT
CRYPTO
STAIR-3
3,000 3,000 1,572 4,572 4,775 1,829
4,568 4,576 2,347 2,225 4,775 1,829
D8 D8
D8
D8
D8
D8
D8
D4 D3
D20
D13
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
KWON, CH
131420
"R" VALUE FOR INSULATION SHALL BE AS FOLLOWS :
D12
D8
SGT MAJ
COMMANDING
OFFICE
XO OFFICE
OFFICE OFFICE
S-1 OFFICE
STORAGE
ROOM
WAITING
TOILET
FEC
W1
LEGEND
200 THK MET STUD WALL
200 THK CMU WALL W/EIFS
150 MM METAL STUD CHASE WALL
W/SOUND PROOF INSULATION
200 OR 150 MM METAL STUD WALL
EXISTING EXTERIOR CMU WALL W/50MM STUD WALL
EXISTING INTERIOR CMU WALL W/50MM OR 90MM STUD WALL
150 MM METAL STUD WALL
A-3
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1
W1W1W1W1W1W1W1W1
69,698
1,829
,6
,8
,9
,7
,9
,8
69,698
27,838
1,829
D15
FEC
D6
W3 W1W2
(GFGI)
OVEN
(GFGI)
MACHINE
ICE MAKE
(GFGI)
REF
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
LAUNDRY
STAIR-1
BALCONY
TV/LOUNGE ROOM
STORAGE
BULK
D17
D9 D9
D10D10
D11
D12
D12
D11
D10 D10
D9 D9
D9
D10 D10
D9
D11
D12
D12
D11
D10 D10
D9 D9 D9 D9
D10 D10
D11
D12
D12
D11
D10D10
D9 D9 D9 D9
D10 D10
D11
D12
D12
D11
D10 D10
D9 D9
D9 D9
D10D10
D11
D12
D12
D11
D10 D10
D9D9
D9
D12
D11
D9
3,454 3,607 3,607 3,302 3,200 3,708 3,591 3,369 6,096 3,251 4,674 3,353 3,607 3,708
14,021
3,454 3,607 3,607 3,302 3,200 3,708 3,607 3,353 4,674 4,674 4,674 4,674 4,674
SCALE: 1 : 100
2ND FLOOR PLAN-1
KEY PLAN 2ND FLOOR PLAN-1
L
S
FEC
W W
W W
W W
W
D
D
D
D
D
D
D
UP
D7D7 D7D7 D7 D7
D7D7 D7D7D7D7 D7D7
D7D7 D7
D7D7
W1 W1
D18
STAIR-2
UP
D16
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
KWON, CH
131420
LEGEND
200 THK MET STUD WALL
200 THK CMU WALL W/EIFS
150 MM METAL STUD CHASE WALL
W/SOUND PROOF INSULATION
200 OR 150 MM METAL STUD WALL
EXISTING EXTERIOR CMU WALL W/50MM STUD WALL
A-4
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
REPAIR / MAINTENANCE (K) WORK
1.
2.
3.
4.
6.
7.
8.
9.
5.
ON NEW FLOOR PLANS AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING FIRE EXTINGUISHER CABINET(FEC) WITH NEW AS SHOWN
11.
12.
13.
14.
15.
16.
17.
18.
TYPE.
REPLACE DETERIORATED EXISTING WINDOW HORIZONTAL MINI BLINDS WITH NEWS, FIREPROOF
19.
20.
21.
22.
SLAB IF NEEDED.
CORRECTED FOR NEW FLOORING. PROVIDE LEVELING CONCRETE FOR EXISTING CONCRETE
CONCRETE, LOW SPOTS, HIGH SPOTS, PAINTING, AND UNEVEN SURFACE SHALL HAVE BEEN
SHALL BE SMOOTH, TRUE, LEVEL PLANE WITH ALL DEFECTS SUCH AS ROUGH OR SCALING
ON FLOOR PLAN & INTERIOR FINISH SCHEDULE. THE EXISTING CONCRETE FLOORING
REPLACE DETERIORATED EXISTING FLOOR TILE WITH NEW PVCT INCLUDING VCB AS SHOWN
10.
AS SHOWN ON FLOOR PLANS AND WINDOW SCHEDULE.
+ 12 THK AIR SPACE + 6 THK TINTED LOW-E TEMPERED GLASS ( SHGC : MAX 0.4 )
THERMAL BREAKER TYPE BLAST WINDOWS INCLUDING 8.75 THK CLEAR LAMINATED GLASS
REPLACE DETERIORATED EXISTING WINDOWS INCL INSECT SCREEN WITH NEW ALUMINUM
23.
24.
25.
26.
W1 W1 W1 W1 W1 W1
W1W1W1W1W1
27,838
4,674
,6
,8
,9
,6
,9
,1
,9
,8
W1
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
D9
D10 D10
D9
D11
D12
D12
D11
D10 D10
D9 D9 D9
D10 D10
D9
D11
D12
D12
D11
D10D10
D9 D9 D9
D10 D10
D9
D11
D12
D12
D11
D10 D10
D9D9
3,708 3,200 3,302 3,607 3,607 3,454 1,829
4,521 3,302 3,607 3,607 3,454 1,829
SCALE: 1 : 100
2ND FLOOR PLAN-2
KEY PLAN
27.
28.
29.
30.
AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING STL TRENCH COVER WITH NEW AS SHOWN ON FLOOR PLAN
31.
REPLACE DETERIORATED EXISTING ALL ACCESS DOORS ON WALL & CEILING WITH NEW.
METAL SUSPENSION SYSTEMS AS SHOWN ON FLOOR PLAN AND INTERIOR FINISH SCHEDULE.
REPLACE DETERIORATED EXISTING CEILING WITH NEW ACOUSTICAL CEILING TILE INCLUDING
ON FLOOR PLANS AND FINISH SCHEDULE.
WATER RESISTANT OR 'X' TYPE) CEILING INCLUDING CEILING SUSPENSION SYSTEM AS SHOWN
REPLACE DETERIORATED EXISTING CEILING WITH NEW GYPSUM WALL BOARD (GWB, NORMAL,
FLOOR PLANS AND DETAIL DRAWINGS.
LATH, MORTAR BED AND WATERPROOFING IN BATHROOM & SHOWER ROOM AS SHOWN ON
REPLACE DETERIORATED EXISTING FT AND GCWT WITH NEW INCLUDING ACCESSORIES, METAL
HARDWARE SETS AS SHOWN ON FLOOR PLANS AND DOOR SCHEDULE.
REPLACE DETERIORATED EXISTING ALL DOORS AND DOOR FRAMES WITH NEW INCLUDING NEW
AS SHOWN ON FLOOR PLAN AND DETAIL.
REPLACE DETERIORATED EXISTING SST LAUNDRY SHELVES WITH NEW IN EACH LAUNDRY ROOM
ELEVATIONS AND SIGNAGE SCHEDULE.
REPLACE INTERIOR & EXTERIOR SIGNAGES WITH NEW FOR ALL ROOMS AS SHOWN ON FLOOR PLAN, FLOOR PLANS AND DEDTAIL DRAWINGS.
BLOCK UP AND PATCH UP WHERE REPLACED FIRE EXTINGUISHER CABINETS AS SHOWN ON
AS SHOWN ON FLOOR PLANS AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING METAL SHELF WITH MOP RACK WITH NEW IN JANITOR ROOM
FLOOR PLAN, SECTIONS AND DETAIL DRAWING. (NATURAL COLOR, OAK)
REPLACE DETERIORATED EXISTING WOODEN SILL FOR ALL WINDOWS WITH NEW AS SHOWN ON
AS SHOWN ON FLOOR PLANS, ELEVATIONS AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING KITCHENETTE INCLUDING BASE CABINET AND UPPER CABINET
DRAWINGS.
SOUND PROOF INSULATIONS (STC 45) AS SHOWN ON FLOOR PLANS, SECTIONS AND DETAIL
REPLACE DETERIORATED EXISTING ALL GWB WALLS WITH NEW INCLUDING METAL STUDS AND
AS SHOWN ON FLOOR PLANS AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING WOODEN SHELVES AND RODS WITH NEW IN EACH WALK-IN CLOSET
SHOWN ON FLOOR PLANS AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING WOODEN SHELF CABINETS WITH NEW IN EACH WALK-IN CLOSET AS
SCOPE OF WORK (ARCHITECTURAL WORK)
2ND FLOOR PLAN-2 AND SCOPE OF WORK
DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING ALL TOILET ACCESSORIES WITH NEW AS SHOWN ON FLOOR PLAN AND
32.
ON FLOOR PLAN AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING AIR INTAKE LOUVERS WITH NEW FOR FAN COIL UNITS AS SHOWN
AND INTERIOR FINISH SCHEDULE & ELEVATIONS.
PAINT ON ALL INTERIOR SURFACES INCLUDING CEILING AND WALL AS SHOWN ON FLOOR PLAN
DRAWING.
INSULATION AND TREATED WOOD NAILER AS SHOWN ON FLOOR PLANS, SECTIONS AND DETAIL
REPLACE DETERIORATED EXISTING BUILT UP ROOF WITH NEW EPDM ROOFING SYSTEM INCLUDING
FLOOR PLANS, ELEVATIONS AND FINISH SCHEDULE.
FASCIA, SOFFIT, KOREA ROOF TILES AND OTHER COMPONENTS OF EXTERIOR SURFACE AS SHOWN ON
PAINT ALL EXISTING EXTERIOR EXPOSED EIFS, CMU, METAL, WOODS, CONCRETE SURFACES, STAIRWEL, PLANS AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING VANITY CABINETS WITH NEW IN EACH TOILET AS SHOWN ON FLOOR
SIGNAGE SCHDULE AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING PLEXI-INFO HOLDER AND CARD HOLDER WITH NEW AS SHOWN ON
D7D7D7D7
D7 D7D7D7D7 D7
D7 D7
STAIR-3
UP
PLYWOODS PLASTIC LAMINATED FILM AS SHONW ON FLOOR PLANS.
PAINT ON EXST METAL STORAGE BINS AND REPLACE DETERIORATED EXST PLYWOOD WITH NEW 18THK
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
KWON, CH
131420
(SEE MECH DRAWING)
REPLACE EXISTING CONCRETE SLAB AS NEEDED TO REPLACE MECHANICAL PIPING WORK ON 1ST FLOOR.
ON FLOOR PLANS AND SECTION.
REPLACE DETERIORATED EXISTING WOODEN HANGER RAILS WITH NEW IN EACH BED ROOM AS SHOWN
IN STAIR-1 AS SHOWN ON FLOOR PLANS AND INTERIOR FINISH SCHEDULE
REPLACE DETERIORATED EXISTING RUBBER TILES WITH NEW INCLUDING TREAD, RISER AND STAIR BASE
PLANS AND DETAIL DRAWINGS.
REPLACE DETERIORATED EXISTING WOODEN SHELVES WITH NEW IN EACH PANTRY AS SHOWN ON FLOOR
DETAIL DRAWINGS.
EACH ROOMS FOR NEW MECHANICAL PIPING SYSTEM AND DUCT AS PER FLOOR PLANS, SECTIONS AND
REPLACE EXISTING PIPE CHASES / PIPE COVER WITH NEW CMU, WATERPROOF OR X TYPE OF GWB IN
LEGEND
200 THK MET STUD WALL
200 THK CMU WALL W/EIFS
150 MM METAL STUD CHASE WALL
W/SOUND PROOF INSULATION
200 OR 150 MM METAL STUD WALL
EXISTING EXTERIOR CMU WALL W/50MM STUD WALL
A-5
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1
W1W1W1W1W1W1W1W1
69,698
1,829
,6
,8
,9
,7
,9
,8
69,698
27,838
1,829
D15
FEC
D6
W3 W1 W2
D N
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
STAIR-1
STORAGE
BULK
GAME ROOM
BALCONY
D9 D9
D10 D10
D11
D12
D12
D11
D10 D10
D9 D9 D9 D9
D10 D10
D11
D12
D12
D11
D10D10
D9 D9 D9 D9
D10 D10
D11
D12
D12
D11
D10 D10
D9 D9 D9
D10 D10
D9
D11
D12
D12
D11
D10
D9
D10
D9
D17 D17
D9 D9
D10 D10
D11
D12
D12
D11
D10
D9
D10
D9 D9
D11
D12
D9
STORAGE
BULK
W1
3,454 3,607 3,607 3,302 3,200 3,708 3,591 3,369 6,096 3,251 4,674 3,353 3,607 3,708
14,021
3,454 3,607 3,607 3,302 3,200 3,708 3,607 3,353 4,674 4,674 4,674 4,674 4,674
SCALE: 1 : 100
3RD FLOOR PLAN-1
KEY PLAN
FEC
FEC
(GFGI)
OVEN
(GFGI)
MACHINE
ICE MAKE
W1
33.
D7D7 D7 D7 D7D7 D7D7
D7D7D7D7D7D7D7D7D7D7
REPAIR / MAINTENANCE (K) WORK
SCOPE OF WORK (ARCHITECTURAL WORK)
34.
35.
D7 D7
36.
CEMENT BOARD, EIFS FINISH COAT ONLY AS SHOWN ON FLOOR PLAN, SECTION AND DETAIL DRAWING.
REPLACE EXISTING EXTERIOR CMU WALL WITH NEW INCLUDING C-CHANNEL, 150THK INSULATION, 3RD FLOOR PLAN-1 AND SCOPE OF WORK
REFINISH CONC FLOOR AS SHOWN ON FLOOR PLANS, SECTION AND DETAIL DRAWING.
REMOVE EXISTING CMU WALL WITH EXTERIOR INSULATION FINISH SYSTEM FOR BLAST DOOR AND CLEAN/
37.
DETAIL DRAWING.
TRANSITIONAL STRIP AT EACH BED ROOM EXTERIOR DOOR AS SHOWN FLOOR PLANS, SECTION AND
REPLACE DETERIORATED EXISTING CRAMIC FLOOR TILES WITH NEW INCLUDING ACCESSORIES AND SST
38.
STAIR-2
UP
REF(GFGI)
D16
FLOOR PLAN AND ELEVATION.
BLOCK UP EXSTING DOOR OPENING WITH 200THK CMU INCLUDING RE-BAR AND EIFS AS SHOWN ON
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
KWON, CH
131420
ROKA-1 OFFICE AS SHOWN ON FLOOR PLAN AND ELEVATION.
CUT AND OPEN EXISTING CMU WALL WITH EIFS FINISH TO REPLACE EXISTING WINDOW WITH NEW IN
39.
SHOWN ON PICTURE.
REPLACE DETERIORATED EXISTING STONE BED WITH GRAVEL WITH NEW IN FRONT OF BUILDING AS
LEGEND
200 THK MET STUD WALL
200 THK CMU WALL W/EIFS
150 MM METAL STUD CHASE WALL
W/SOUND PROOF INSULATION
200 OR 150 MM METAL STUD WALL
EXISTING EXTERIOR CMU WALL W/50MM STUD WALL
EXISTING INTERIOR CMU WALL W/50MM OR 90MM STUD WALL
150 MM METAL STUD WALL
ON PICTURE.
REPAIR DAMAGED CONCRETE FLOORS ON 2ND AND 3RD FLOOR BALCONIES AS NEEDED AS SHOWN
40.
& 124 WITH NEW AS SHOWN ON FLOOR PLAN AND ELEVATION.
REPLACE DETERIORATED EXISTING WINDOW SECURITY BARS WITH PAINTING AT ROOM # 109, 112, 126
A-6
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
W1 W1 W1 W1 W1 W1
W1W1W1W1W1
27,838
4,674
,6
,8
,9
,6
,9
,1
,9
,8
W1
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
BED ROOM
D9
D10 D10
D9
D11
D12
D12
D11
D10D10
D9D9 D9
D10 D10
D9
D11
D12
D12
D11
D10 D10
D9 D9 D9
D10 D10
D9
D11
D12
D12
D11
D10 D10
D9D9
3,708 3,200 3,302 3,607 3,607 3,454 1,829
4,521 3,302 3,607 3,607 3,454 1,829
SCALE: 1 : 100
3RD FLOOR PLAN-2
KEY PLAN
EXIST SLAB
L-50x50x62EA-
50x50x6 PLATE WELD TO FRAME
W/12 DIA EXP BOLT @ EACH FRAME
L-50x50x6
STL FRAME
M A
T C
H
T O
F C
U
E
IG
H T
@ 400 OC (TYP)ON 92 MET STUD
ACCESS DOOR
AT 1ST FLOOR ONLY
PIPE COVER DETAIL
(COLOR TO MATCH FCU)
1.2mm THK. STEEL SHT COVER
VCB
SCALE:
PIPE CHASE AND COVER DETAILS
N/A
PIPE CHASE
EXISTING WALL2A
2A
PIPE COVER DETAIL
EXST CMU WALL OR GWB WALL
STL FRAME @400 O.C.
PAINT 15 THK FIRERATED GWB
200W x 200H
3RD FLOOR PLAN-2 AND DETAILS
D7D7 D7D7
D7 D7 D7 D7 D7 D7
D7D7
STAIR-3
UP
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
KWON, CH
131420
LEGEND
200 THK MET STUD WALL
200 THK CMU WALL W/EIFS
150 MM METAL STUD CHASE WALL
W/SOUND PROOF INSULATION
200 OR 150 MM METAL STUD WALL
EXISTING EXTERIOR CMU WALL W/50MM STUD WALL
A-7
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
GL.GL.
GL.GL.
1ST FL 1ST FL
1ST FL 1ST FL
SCALE: 1 : 200
ELEVATION-1
SCALE: 1 : 200
ELEVATION-2
SCALE: 1 : 200
ELEVATION-4
SCALE: 1 : 200
ELEVATION-3
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
KWON, CH
131420
TRASH BIN
SCALE:
PICTURES
N/A
EIFS (TYP)
PAINT ON EXST
(TYP)
AND ALL METAL SURFACES
PAINT ON EXST PM ROOF
(TYP)
INSECT SCREEN
CONC FLOOR (TYP)
REPAIR DAMAGED
CONC FLOOR (TYP)
REPAIR DAMAGED
BALCONY FLOOR BALCONY FLOOR GRAVEL BED
(TYP)
100THK GRAVEL BED
(TYP)
WINDOW SECURITY BAR
(TYP)
WINDOW SECURITY BAR
ELEVATIONS AND PICTURES
SEE MECH DWG
LOUVER, 600 X 400
A-8
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
2.PIPE SURFACE MUST BE FREE OF ALL RUST,
PIPE MUST BE ANCHORED TO ENSURE STABILITY.3.
GREASE, INSULATION, ETC.
4.APPLY LAP SEALANT AROUND ENTIRE PERIMETER
OF FLASHING.
BONDING ADHESIVE REQUIRED BETWEEN
MEMBRANE AND INSULATION FOR FULLY
ADHERED SYSTEMS.
1.
5.SHOP DRAWING OF ROOF SYSTEM SHALL BE
PROVIDED PER MFR'S STANDARD FOR APPROVAL.
ROOFING
EPDM REINFORCED
REINFORCED EPDM MEMBRANE,
STANDARD AND FIRE RETARDANT,
LIGHT GRAY COLOR FINISH
VERIFY INSTALLATION
SYSTEM FOR ARCH AREA
OR APPROVED EQUAL
MEMBRANE ROOFING
PER ROOFING MFR'S
W/ SUPPORTS & ACCESSORIES
FIRESTONE CO.,
1.14 MM THICK,
6.EPDM ROOFING SYSTEM
100 100600(+)
CONC SLAB
PVCT ON EXST
CMU WALL
EXIST
TRENCH
CONC
EXIST
CLEAN INSIDE
EXIST
E X
IS
T
SCALE:
SCALE:
SCALE:
GENERAL CROSS SECTION
1 : 50
A-8
ROOF DETAIL (TYP)
1 : 20
CLEAN SST HANDRAIL
EPDM NOTES:
GENERAL CROSS SECTION & DETAILS
13,614
1,8296,0961,4226,0961,829
,6
,8
,8
,8
KOREAN ROOF TILE (TYP)
PAINT ON EXST
N/A
& WALL (TYP)
COLUMN, CEILING
PAINT ON EXST
& WALL (TYP)
COLUMN, CEILING
PAINT ON EXST
(TYP)
CEILING
PAINT ON GWB
(TYP)
(OAK, NATURAL FINISH)
WOODEN SILL
(TYP)
METAL FLASHING
(TYP)
WINDOW BLIND
(TYP)
AL BLAST WINDOW
(TYP)
TRENCH COVER ONLY
6 THK STL PL
PVCT ON
(TYP)
EXST METAL ANGLE
PAINT ON EXST STL. PIPE POST
RIGID INSULATION
RUBBERGARD EPDM
BY ROOFING MFR (TYP)
BY ROOFING MFR (TYP)
A-8
TREATED
WD NAILER
12D EXP BOLT
@900 O.C. (TYP)
(TYP)
WATERPROOFING ON CONC SLAB
APPLY ACRYLIC FLUID-APPLIED
CEILING (TYP)
PAINT ON GWB
CEILING (TYP)
PAINT ON GWB
MTL COVERED TRENCH DETAIL
(TYP)
EPDM ROOFING SYSTEM
(TYP)
ON C-150X75X50X3.2
WITH 150T INSULATION
ON 12T CEMENT BOARD
EIFS FINISH COAT ONLY
(TYP)
W/CHIPPING EXST CONC SLAB
BOND COAT ON MORTAR BED
W/TRANSITIONAL STRIP AND CEMENT
210X600X8T CERAMIC FLOOR TILE
& WALL (TYP)
COLUMN, CEILING
PAINT ON EXST
ACST (TYP)
CORRIDORS-3 S-4
12T CEMENT BOARD (TYP)
REINFORCING FABRIC ON
EIFS BASE COAT ON
EIFS FINISH COAT ON
(TYP)
WITH SOUNDPROOF INSULATION
ON 200 MTL STUD @400 O.C
PAINT ON 15T GWB
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
KWON, CH
131420
A-9
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
& INTERIOR ELEVATIONS - 1
ENLARGED FLOOR PLANS
M
P
R
C K
MOP RACK
,8
GCWT
SCALE:
ENLARGED FLOOR PLAN-1
1 : 50
SCALE: 1 : 50
ELEVATION @ J/C
S/S
SCALE:
ENLARGED FLOOR PLAN-2
1 : 50
SCALE: 1 : 50
ELEVATION @ LAUNDRY
FEC
122121
W. TOILET M. TOILET
W1 W1
D3 D3 D3
3,9702,803
,6
US
ON 200 MTL STUD (TYP)
ON 12T CEMENT BOARD
ON WATERPROOF MEMBRANE
GCWT ON CEMENT BOND COAT
PTDWR
PTDWR
TTD
GB US
US
US
GB
GB
TTD
TTDTTD
TTD
GB
WC
WC WC
WC
JAN
LAUNDRY
L
S
W W
W W
W W
W D
D
D
D
D
D
D
D19
4,470
,3
L/S
SCALE: 1 : 50
ELEVATION @ TOILET
S
IN
K
ON 200 MTL STUD (TYP)
ON 12T CEMENT BOARD
ON WATERPROOF MEMBRANE
GCWT ON CEMENT BOND COAT
LAUNDRY SST SHELF
,3
,3
US US
2,400
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
KWON, CH
131420
W1W1
TOILET
SGT MAJ
COMMANDING
SCALE:
ENLARGED FLOOR PLAN-3
1 : 50
,8
2,400
TTD
WC
SCALE: 1 : 50
ELEVATION @ TOILET, RM 104
PTD
ON 150 MTL STUD (TYP)
ON 12T CEMENT BOARD
ON WATERPROOF MEMBRANE
GCWT ON CEMENT BOND COAT
INSULATION (TYP)
SOUNDPROOF
,0
1001,200100
SCALE: 1 : 50
ELEVATION @ EOC, WALL OPNG
NATURAL FINISH
TRIM, OAK
CHASE WALL (TYP)
PAINT ON GWB
,3
W/50X50 WD FRAME
ON 18 THK PLYWOOD
12T SOLID SURFACE MATERIAL
SST SHELF
W1 W1
W1W1
BED ROOMBED ROOM
BED ROOM
BED ROOM
D7 D7
D7D7
D9 D10 D10
D9
D11
D12
D12
D11
D9
D10 D10
D9
6,909
3,7263,200
,9
,1
,8
,8
,9
,6
PANTRY
CLOSET
WALK-IN
CLOSET
WALK-IN
CLOSET
WALK-IN
CLOSET
WALK-IN
PANTRY
AREA
SERVICE
AREA
SERVICE
SCALE:
TOILET TOILET
TYP ENLARGED FLOOR PLAN
1 : 50
SCALE: 1 : 50
ELEVATION @ WALK IN CLOSET
SHELF & ROD
THK PLYWD
PL-1 ON 18
GWB WALL (TYP)
FIRERATED 15T
(TYP)
RAIL NATURAL OAK
WOODEN HANGER
(TYP)
RAIL NATURAL OAK
WOODEN HANGER
(TYP)
RAIL NATURAL OAK
WOODEN HANGER
INSULATION (TYP)
SOUNDPROOF
INSULATION (TYP)
SOUNDPROOF
±356
(TYP)
ON C-150X75X50X3.2
W/ 150T INSULATION
PAINT ON 15T GWB
ON C-150X75X50X3.2 (TYP)
WITH 150T INSULATION
ON 12T CEMENT BOARD
EIFS FINISH COAT ONLY
(TYP)
ON 12T CEMENT BOARD
W/ ON EIFS FINISH COAT ONLY
ABOVE CEILING LINE
REFINISH CONC FLOOR (TYP)
AND INTERIOR FINISH, AND
REMOVE CMU WALL, EIFS,
(TYP)
W/ CHIPPING EXST CONC SLAB
ON MORTAR BED
W/SST TRANSITIONAL STRIP
CERAMIC FLOOR TILE
WC
MC
SCALE: 1 : 50
MG
LIGHTING (ELEC)
TB
SD
GCWT
SCR W/SC
SH
SH
SHOWER CURVE
ELEVATION @ TOILET & SERVICE AREA
(NIC)
MICROWAVE
GCWT
A-10
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
W1
D19
FEC
(GFGI)
OVEN
(GFGI)
MACHINE
ICE MAKE
(GFGI)
REF
TV/LOUNGE ROOM
D6
REF
(NIC)
RANGE
RANGE
HOOD(CFCI)
(NIC)
OVEN
(NIC)
MACHINE
ICE MAKE
9,347
SCALE: 1 : 50
GCWT
TOP CABINET
BASE CABINET
ELEVATION @ GAMEROOM
1,500
SCALE:
ENLARGED FLOOR PLAN-1
1 : 50
,0
,6
& INTERIOR ELEVATIONS - 2
ENLARGED FLOOR PLANS
AND TV/LOUNGE ROOM
ON 50 MTL STUD
ON 12T CEMENT BOARD
GCWT ON CEMENT BOND COAT
ON 150 MTL STUD (TYP)
ON 12T CEMENT BOARD
GCWT ON CEMENT BOND COAT
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
KWON, CH
131420
(TYP)
ON 50 MTL STUD
PAINT ON 15T GWB
129127
VAULT
CRYPTO
OFFICE OFFICE
STORAGE
W1 W1
D8 D8
D00
D13
S-2 OFFICE
(TYP)
@200 O.C TO UPPER CONC SLAB
ON 200THK CONC WALL W/RE-BAR
PAINT ON GWB W/50THK MTL STUD
(TYP)
@200 O.C TO UPPER CONC SLAB
W/RE-BAR & CHEMICAL BOLT
ON 200THK CONC WALL
PAINT ON SKIM COAT
SCALE:
ENLARGED FLOOR PLAN-2
1 : 50
A-11
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
BED ROOM
BED ROOM
@400 O.C.
50 METAL STUD
@1,200 O.C.
50 METAL BLOCK'G
@400 O.C.
50 METAL STUD
@1,200 O.C.
50 METAL BLOCK'G
@400 O.C.
50 METAL STUD
@1,200 O.C.
50 METAL BLOCK'G
MINI-BLIND
MINI-BLIND
MINI-BLIND
25x38 WOOD NAILER
FRONT STRIP
38x50 HARD WOOD
@400 O.C.
90 MET STUD
@600 0.C.
90 W. MTL. BLOCK'G
@400 0.C.
90 W. MTL. STUD
VCB
VCB
MTL. FLASHING
VCB
MTL LATH (3.4#/SY)
CEMENT MORTAR BED
WATER-PROOFING
SHOWER RM.
TOILET/
CLOSET
WALK-IN
WALK-IN CLOSET
PANTRY
FIN AS SCHD
FIN AS SCHD
VCB
FIN AS SCHD
12 THK CEMENT BOARD
AS SCHD
FINISH
AS SCHD
FINISH
@1,200 O.C.
90 W MTL BLOCK'G
@400 O.C.
90 W MTL STUD
AS SCHD
FINISH
VCB
AS SCHD
FINISH
EXST EIFS
PAINT ON
MTL. FLASHING
EXST EIFS
PAINT ON
MTL. FLASHING
EXST EIFS
PAINT ON
GUARDRAILS
CLEAN EXST SST
GUARDRAILS
CLEAN EXST SST
EXST COLUMN
PAINT ON
EXST COLUMN
PAINT ON
EXST COLUMN
PAINT ON
EXST BEAM
PAINT ON
EXST BEAM
PAINT ON
EXST BEAM
PAINT ON
EXST ROOF
PAINT ON
,8
,8
,7
,0
,2
W
IN
D
W
E N 'G
.0
,2
.0
,2
1st
3rd
W
IN
D
E N 'G
W
IN
D
E N 'G
GL
2nd.
EXST CONC SLAB
EXST CONC SLAB
EXST CONC SLAB
,6
,3
C L
G
T
,3
C
T
,3
C
T
,3
C
T
,8
KEY PLAN
SCALE: 1 : 20
WALL SECTIONS
1A
1B 1D
1E 1F
WOODEN
@1,200 O.C.
150 W MTL BLK'G
@400 O.C.
150 W MTL STUD
VCB
(STC=45)
SOUNDPROOF INSULATION
(STC-45)
SOUNDPROOF INSULATION
SHELF & ROD
(OAK, NATURAL FINISH)
WOODEN SILL
(OAK, NATURAL FINISH)
WOODEN SILL
(OAK, NATURAL FINISH)
WOODEN SILL
WALL SECTIONS
PAINT ON EXST STL. PIPE POST
GCWT ON CEMENT BOND COAT
KOREAN ROOF TILE (TYP)
PAINT ON EXST
FIRERATED GWB CLG
PAINT ON 12 THK
FIRERATED
15 THK GWB
PAINT ON
FIRERATED GWB CLG
PAINT ON 12 THK
FIRERATED
15THK GWB
PAINT ON
WATERPROOF GWB CLG
PAINT ON 12 THK
CEMENT MORTAR BED
WATERPROOFING MEMBRANE
FT ON CEMENT BOND COAT
FIRERATED
15 THK GWB
PAINT ON
FIRERATED GWB CLG
12 THK
PAINT ON
GWB CLG
12 THK FIRERATED
PAINT ON
FIRERATED
15 THK GWB
PAINT ON
FIRERATED
15 THK GWB
PAINT ON
12 THK FIRERATED GWB CLG
PAINT ON
PAINT ON 15 THK GWB
12 THK GWB CLG
PAINT ON
PAINT ON 15 THK GWB
PAINT ON 15 THK GWB
PL-1 ON 19T PLYWOOD
EXST CONC TRENCH
1A
1C
1B
1E
1F
1D
HANGER RAIL(TYP)
BED ROOM BED ROOM
PANTRY
MTL. FLASHING
PAINT ON EXST
RIGID INSULATION
BY ROOFING MFR
RUBBERGARD EPDM
BY ROOFING MFR
TREATED
WD NAILER
12D EXP BOLT
@900 O.C. (TYP)
OFFICE
ACST CEILING
1C
VCB
AS SCHD
FINISH
,3
C
T
WOODEN
FIRERATED GWB CLG
PAINT ON 12 THK
HANGER RAIL(TYP)
BED ROOMBED ROOM
@400 O.C.
150 MTL STUD
@1,200 O.C.
150 W MTL BLK'G
(STC=45)
SOUNDPROOF INSULATIONGWB (TYP)
FIRERATED
15 THK
PAINT ON
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
KWON, CH
A-12
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
2A
2C
13 THK SOLID SURFACING
MATERIAL (SSM-1) ON 18 THK
SEALANT
20x100
WD SHIM
WD SHIM
20x100
2B
2D
C
T
20X100 WD
(SEE ELEC DWG)
LIGHTING
MIRROR ON 7.5 THK PLYWD
POST-FORMED 13 THK
SOLID SURFACING MATERIAL
ON 7.5 THK PLYWD
MARINE EDGE
ON 18 THK PLYWOOD
PLASTIC LAMINATE (PL-1)
10 DIA POLISHED BRASS ROD
PULL @ EACH DOOR (B02011)
ON 7.5 THK PLYWOOD(FRONT)
PLASTIC LAMINATE (PL-2)
W/ HINGE (2PR-BO1602
@ EACH DOOR)
PLASTIC LAMINATE (PL-2)
ON 18 THK PLYWOOD
(TOP & EDGE)
(FRONT, BACK & EDGE)
1B
1C
1A SCALE : 1/10
LAV BOWL
(SEAMED UNDERMOUNT)
5B
5A
SECTION
P L A N
6 THK CEMENT BOARD
6 THK CEMENT BOARD
PORCELAIN SOAP HOLDER
MORTAR BED
CERAMIC TILE
SOAP HOLDER
PORCELAIN
TOWEL BAR
BOLT
CONNECTED METAL
METAL CHANNEL
STUD
METAL STUD
@ 406 OC
2C
2B
2D
2A
L-50x50x6x50LG STL
PLASTIC LAMINATED (PL-2)
ON 18 THK PLYWD(TOP)
ON 7.5 THK PLYWD
PLASTIC LAMINATED (PL-2)
FIXED TO WD BLOCK &
50x100 WD
BLOCK
SILICONE SEALANT
30x50 HARDWD
18X18 HARDWD TRIM
W/ PLASTIC LAMINATED
POST-FORMED 13 THK
ON 18 THK PLYWOOD
MARINE EDGE
(FRONT, BACK & EDGE)
PLASTIC LAMINATED (PL-1)
ON 18 THK PLYWD
SOLID SURFACING (SSM-1) MATERIAL
50x100 WD BLOCK
WD BLOCK & TO
CONC SLAB W/
6DIA EXP BOLTS
@ 450 OC
L-50x50x6x50LG STL
CLIP FIXED TO
18 x 18
PLASTIC LAMINATED (PL-2)
ON 18 THK PLYWD
PLASTIC
PLYWD
& EDGE)
ON 7.5 THK PLYWOOD
PLASTIC LAMINATED
ON 18 THK PLYWOOD
POST-FORMED 13 THK
SOLID SURFACING (SSM-1) MATERIAL
(FRONT)
HARDWD TRIM
ON 18 THK
LAMINATED (PL-1)
(FRONT, BACK
W/ PLASTIC
LAMINATED (PL-1)
(TOP & EDGE)
MIRROR ON 7.5 THK PLYWD
WATER PROOFING
EXP BOLT @ 450 OC
TO CONC SLAB W/6 DIA
SEAL W/ BOLT
FOR WATER PROOFING
7.5 THK PLYWOOD
W/ GLUE
6 THK MIRROR ON
6 THK MIRROR ON
MATERIAL
SURFACING
13 THK SOLID
POST-FORMED
SEALANT
W/ GLUE
7.5 THK PLYWOOD
SST FRAME
12 THK CEMENT
BOARD
BOARD
12 THK CEMENT
SST FRAME
POST-FORMED
13 THK SOLID
SURFACING
MATERIAL
SEALANT
1C
1B SCALE : 1/2
SCALE : 1/2
SCALE:
TYP LAVATORY COUNTER DETAIL
AS SHOWN
SCALE: 1:10
TOWEL BAR DETAIL
SCALE: 1:10
SOAP HOLDER DETAILS
SCALE: 1:5
D E T A I L S
A-12
A-12
A-12
A-11
A-12A-12
MISC DETAILS-1
SCALE: 1 : 5
SHOWER CURB DETAILS
SCALE:
1:5
VCB
VCB
PLYWOOD (COUNTER TOP&BACK)
GCWT ON
CEMENT BOND COAT
ON WATERPROOFING
MEMBRANE ON
PLASTERING W/METAL LATH
GCWT ON
CEMENT BOND COAT
ON WATERPROOFING
MEMBRANE ON
PLASTERING W/METAL LATH GCWT ON
CEMENT BOND COAT
ON WATERPROOFING
MEMBRANE ON
PLASTERING W/METAL LATH
2.0 THK SST SHELF
SUPPORT FRAME @ 800 O.C
@ EACH SUPPORT FRAME
FACE OF WALL
O O
R
250 200
SST SHELF DETAIL @ LAUNDRY
BATH ROOM
4 THK BENT
W/ 6 DIA EXP BOLTS
@ 300 OC
SST BASE (WELDED)
SEALANT
SHOWER AREA
W/ ADHESIVE
SLOPE
SHOWER CURTAIN
W/ROD
MEMBRANE
WATER PROOFING
CEMENT MORTAR
BED
CERAMIC FLOOR
TILE
MEMBRANE
WATER PROOFING
CEMENT MORTAR
BED
CERAMIC FLOOR
TILE SLOPE
R=5
12 THK SSM
SHOWER CURTAIN
L
W/6 DIA TOGGLE
TOWEL BAR
FLANGE
BOLT
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
A-13
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
4B SECTION
& FINISH SYSTEM
EXT INSUL
FILL GROUT
FL LEVEL
& FINISH SYSTEM
EXT INSUL
AL SHEET FLASHING
SEALANT
SSTL PLATE
5 THK BENT
4B
4A ELEVATION
& FINISH SYSTEM
EXT INSUL
SSTL PLATE
5 THK BENT
FL LEVEL
DASHED LINE FOR
(BEYOND)
LOUVER
(SEE MECH DWG)
5A 5C
SCALE: 1:10
FIRE EXTINGUISHER CABINET DETAIL
SCALE: 1:10
AIR INTAKE LOUVER DETAILS
SCALE:
1:5
MISC DETAILS-2
OAK PLUG
40 x 100
OAK RAIL
@600 O.C.
.F
L
PAINT ON
1 : 5SCALE:
WOODEN HANGER RAIL
METHODS OF WALL
FASTENING
BOLT &
3-1.5 THK SST SHELF
TOGGLE BOLT OF EXP
BRACKET W/ 2 -6
1.2 THK SST SHELF
NEED CNETER BRKT
/o
SST HOOK
SST MOP HOLDER
@300 O.C
SCALE:
1 : 4
MOP RACK DETAIL
(OUTSIDE TRIM DIM.)
(OUTSIDE TRIM DIM.)
(INSIDE BOX DIM.)
FIRE EXTINGUISHER CABINET PLAN
E L E V A T I O N
L
SCALE:
IN
S
ID
B
X
D
IM
O
U T S
METAL DOOR
PULL
SCALE:
METAL TRIM
METAL FIRE
EXTINGUISHER CABINET
METAL DOOR PULL
GLASS
(INSIDE BOX DIM.)
WOOD SHIM
(ALL AROUND)
200 CMU WALL
CONC.FILL
IN
S
B
X
CONC.FILL
S E C T I O N "A-A"
SCALE:
FLOOR FINISH
VCB
LINE
PULL
METAL DOOR
WOOD SHIM
(ALL AROUND)
SIDE)
SCREW (3-PER
A
A
44 305 44
1 : 10
1 : 10 1 : 10 1B
1A
1C
PAINT
ON EXST CMU
CONC.
PRECAST
CONC.
PRECAST
HANGING ROD
4 DIA HOLE (TYP)
CLOTHES
25 DIA SST PIPE
-25x25x2
2.5 THK SST
BRACKET
22x200 WOOD
1.6 THK SST SOCKET
CLOTHES HANGING ROD
25 DIA SST PIPE
5 50
0 50
PAINT GWB
@ 900 OC
BOLTS
9 DIA TOGGLE
PLASTIC LAMINATE (PL-1)
O O
R
HANGING ROD
SST BRACKET
CLOTHES
2.5 THK
25 DIA SST PIPE
-25x25x2 SST BRACKET
POSTFORM
BOTH SIDES-SHELF & SIDE PANEL
ON 18 THK PLYWD
PLASTIC LAMINATE (PL-1)
ON 18 THK PLYWD
SEE DETAIL
@ 900 OC
100350
@ 900 OC
5C
5B
TYP WINDOW SILL DETAIL
SEALANT
(BY WINDOW MFR)
18 THK WOOD TRIM
(NATURAL OAK
W/VARNISH FINISH)
15 THK GWB
@ 400 OC (MAX)
SEALANT
CLOSURE
MINI-BLIND
INSECT SCREEN
GLASS
FLASHINGAL SHEET
SCALE: N/A
INSULATED BLAST
ON 50 MET STUD
TYP SHELF & ROD DETAILS @ WALK-IN CLOSET
A S I T I S
A S I T I S
PAINT ON GWB
BOLT @ 300 O.C.
9 DIA TOGGLE
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
KWON, CH
GWB (TYP)
CEILING LINE
PULL @ EACH DOOR
(B02011) 10 DIA POLISHED
C
T
20x100
(TYP)
WD SHIM
PLASTIC LAMINATE (PL-1)
(TOP,BOTTOM, & EDGE)
ON 18 THK PLYWOOD
REF (GFGI)
7.5 THK PLYWOOD (FRONT)
PLASTIC LAMINATE (PL-2)
(B04071 & B04081)
PLASTIC LAMINATE (PL-2)
PLASTIC LAMINATE (PL-2)
ON 18 THK PLYWOOD
ON 18 THK PLYWD
PLASTIC LAMINATE(PL-2)
MET ADJ SHELF HARDWARE
(TOP,BOTTOM & EDGE)-TYP
(BOTTOM & EDGE)-TYP
2PR - B01602 @ EACH DOOR)-TYP
(FRONT, BACK & EDGE W/HINGES
PLASTIC LAMINATE (PL-1) ON 18 THK PLYWD
ON 7.5 THK PLYWOOD (FRONT)-TYP
PLASTIC LAMINATE (PL-1)
PULL @ EACH DOOR
(TOP,BOTTOM, & EDGE)-TYP
ON 18 THK PLYWOOD
LIGHTING FIXTURE (SEE ELEC DWG)
(B02011) 10 DIA POLISHED BRASS ROD
18 THK PLYWOOD
ON METAL STUD WALL
ON 12 THK CEMENT BD
MARINE EDGE
13 THK SOLID SURFACE
MATERIAL (SSM-1) OVER
KITCHEN SINK
(SEE MECH DWG)
(COUNTERTOP, BACK &
SIDE SPLASH)
ON 18 THK PLYWOOD
PLASTIC LAMINATE (PL-1)
10 DIA POLISHED BRASS ROD
PULL @ EACH DOOR (B02011)
25X50 WD
VCB
ON 7.5 THK PLYWOOD(FRONT)
PLASTIC LAMINATE (PL-2)
W/ HINGE (2PR-BO1602
@ EACH DOOR)-TYP
PLASTIC LAMINATE (PL-2)
ON 18 THK PLYWOOD
BOLTS @600 OC
X50 LG W/ 12DIA EXP
50X100 WD & 50X50X6
(TOP & EDGE)-TYP
(FRONT, BACK & EDGE)
20x100
(TYP)
WD SHIM
5D
5C
PULL @ EACH DOOR
(B02011) 10 DIA POLISHED BRASS ROD
7.5 THK PLYWOOD (FRONT)
PLASTIC LAMINATE (PL-2)
ON 18 THK PLYWD
PLASTIC LAMINATE (PL-2)
(TOP,BOTTOM & EDGE)
MICROWAVE(GFGI)
PLASTIC LAMINATE (PL-1)
(TOP,BOTTOM, & EDGE)
ON 18 THK PLYWOOD
ON METAL STUD WALL
ON 12 THK CEMENT BD
GCWT ON THINSET MORTAR
BOLTS @600 OC
X50 LG W/ 12DIA EXP
50X100 WD & 50X50X6
C
T
20x100
(TYP)
WD SHIM
5D
VCB
5B
5A
18 THK PLYWOOD
(COUNTERTOP, BACK &
13 THK SOLID SURFACE
MATERIAL (SSM-1) OVER
SIDE SPLASH)
MARINE EDGE
@ EACH DOOR
PULL
PLASTIC LAMINATE (PL-2)
ON 7.5 THK PLYWOOD
(TOP, BOTTOM & EDGE)
METAL
ADJUSTABLE
25X50 WD
PLASTIC LAMINATE (PL-2)
ON 18 THK PLYWOOD
BRASS ROD
CEILING LINE
PLASTIC LAMINATE (PL-1)
ON 18 THK PLYWOOD (FRONT)-TYP
50x100 WD FRAME (TYP)CEILING LINE
PLASTIC LAMINATE (PL-1)
ON 18 THK PLYWOOD (FRONT)-TYP
50x100 WD FRAME (TYP)
C
T
(FRONT)
CEILING LINE
RANGE HOOD
(SEE MECH DWG)
PULL @ EACH DOOR
(B02011) 10 DIA POLISHED
C
T
20x100
(TYP)
WD SHIM
PLASTIC LAMINATE (PL-1)
(TOP,BOTTOM, & EDGE)
ON 18 THK PLYWOOD
ON METAL STUD WALL
ON 12 THK CEMENT BD
GCWT ON THINSET MORTAR
7.5 THK PLYWOOD (FRONT)
PLASTIC LAMINATE (PL-2)
BRASS ROD
50x100 WD FRAME (TYP)
PLASTIC LAMINATE (PL-1)
ON 18 THK PLYWOOD (FRONT)
ON METAL STUD WALL
ON 12 THK CEMENT BD
GCWT ON THINSET MORTAR
ON 12 THK CEMENT BD
5C
5B 5D
5A
L-50x50x6x50LG STL
PLASTIC LAMINATED (PL-2)
ON 18 THK PLYWD(TOP)
ON 7.5 THK PLYWD
PLASTIC LAMINATED (PL-2)
EXP BOLT @ 450 OC
FIXED TO WD BLOCK &
TO CONC SLAB W/6 DIA
50x100 WD
BLOCK
SILICONE SEALANT
30x50 HARDWD
18X18 HARDWD TRIM
W/ PLASTIC LAMINATED
POST-FORMED 13 THK
ON 18 THK PLYWOOD
MARINE EDGE
(FRONT, BACK & EDGE)
PLASTIC LAMINATED
ON 18 THK PLYWD
SOLID SURFACING (SSM-1)
DRAWER STOPPER
20x40 HARD WD
W/ PLASTIC
LAMINATED
(TOP)
ON 7.5 THK PLYWD
PLASTIC LAMINATED (PL-2)
50x100 WD BLOCK
WD BLOCK & TO
CONC SLAB W/
6DIA EXP BOLTS
@ 450 OC
L-50x50x6x50LG STL
CLIP FIXED TO
18 x 18
VCB
PLASTIC
PLYWD
& EDGE)
ON 7.5 THK PLYWOOD
ON 18 THK PLYWOOD
POST-FORMED 13 THK
SOLID SURFACING (SSM-1) MATERIAL
(FRONT)
HARDWD TRIM
ON 18 THK
LAMINATED (PL-1)
(FRONT, BACK
W/ PLASTIC
LAMINATED (PL-1)
(TOP & EDGE)
MATERIAL
(PL-1)
A-14
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
SCALE: 1:10
CABINET DETAIL
SCALE: 1:10
CABINET DETAIL
SCALE: 1:10
UPPER CABINET DETAIL
SCALE: 1:10
UPPER CABINET DETAIL
SCALE: 1:5
D E T A I L S
PLASTIC LAMINATED (PL-2)
A-14 A-14
A-14
A-14
A-14
KITCHEN CABINET NOTE
(PL-1).
PLYWD PANEL W/ PLASTIC LAMINATE
CONSTRUCTED OF SOLID WD TRIMS &
END PANEL AND ETC. SHALL BE
INCLUDING DOOR, DRAWER FRONTS, SIDE
ALL EXPOSED COUNTER CABINET FACES
5.
6.
(PL-2).
FINISHED W/ PLASTIC LAMINATE
ALL CABINET INSIDE SURFACE SHALL BE
7.
PL-1:
BY FORMICA OR APPROVED EQUAL.
7737-58, NATURAL CHERRY, MATTE
PLASTIC LAMINATE, COLOR:
PL-2:
BY FORMICA OR APPROVED EQUAL.
756-58, NATURAL MAPLE, MATTE
PLASTIC LAMINATE, COLOR:
SSM-1:
EQUAL.
MOSAIC BY FORMICA OR APPROVED
SOLID SURFACE, COLOR #651, CHICORY
FOR THE SOUND SILENCE.
EQUIPPED WITH RUBBER BUMPER
ALL CABINET DOORS SHALL BE
AND TO BE INSTALLED BY OTHER.
GOVERNMENT FURNISHED MATERIALS
MICROWAVE,RANGE AND REFRIGERATOR WILL BE 1.
2.
3.
4.
FINISHED W/ SOLID SURFACE MATERIAL (SSM-1).
ALL CABINET COUNTERTOP SHALL BE
8.
SOLID SURFACE MATERIALS FOR APPROVAL.
OF HARDWARE, PLYWOOD, PLASTIC LAMINATE &
AND TEST REPORTS, CERTIFICATIONS
OF KITCHEN CABINETS WITH HARDWARE,
CONTRACTOR SHOULD SUBMIT SHOP DRAWING
TWO (2) INCHES ACTURAL SIZE OF THE REF.)
JOB SITE, (REFRIGERATOR SPACE SHALL BE
AND CABINET SIZE WILL BE ADJUSTED ON THE
REFRIGERATOR DIMENSION IS APPROXIMATE
SELECTED BY USING AGENCY.
PLASTIC LAMINATED COLOR TO BE
CABINET DETAILS
GCWT ON CEMENT BOND COAT
GCWT ON CEMENT BOND COAT
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
A-15
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
ABBREVIATION
INTERIOR FINISH SCHEDULE
SURFACE
ROOFING
FLASHING
FASCIA
SOFFIT
DOOR & FRAME
MATERIAL
ROOF LINER
STEEL
COLOR
CHOCOLATE
COLOR NO.
20095
CHOCOLATE
CHOCOLATE
CHOCOLATE
CHOCOLATE
20095
20095
20095
20095
REMARKS
WALL EIFS
WALL CMU
BEAM/COL CONC
STAIR CONC
SAND-STONE
SAND-STONE
SAND-STONE
SAND-STONE
23617
23617
23617
23617
PROTECTED METAL
PROTECTED METAL
PROTECTED METAL
EXTERIOR COLOR SCHEDULE-1
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FIRE EXTINGUISHER CABINETFEC
GYPSUM WALL BOARD
SOUND ABSORPTION WALL PANEL
QT QUARRY TILE
VINYL COVE BASEVCB
SAWP
FACTORY FINISH
GWB
FF
CERAMIC MOSAIC TILE
EXTERIOR INSULATION & FINISH SYSTEM
SKIM COAT OF PLASTER
CMT
EIFS
ACOUSTICAL TILEACST
CMU CONCRETE MASONRY UNIT
CPL CEMENT PLASTER
PVCT
MATERIAL & COLOR SCHEDULE
FLOOR MATERIAL/COLOR BASE MATERIAL/COLOR
WALL MATERIAL/COLOR
CEILING MATERIAL/COLOR
PVCT-1
OR APPROVED EQUAL
457.2MMx457.2MM, 3MM THK
KCC SENSE TILE, CERAMIC, TN2412C
PVC TILE
PVC TILE
TC TEXTURE COATING
AWP ACOUSTIC WALL PANEL
AND MATERIAL & COLOR SCHEDULE
INTERIOR, EXTERIOR FINISH SCHEDULE
FINISH SCHEDULE NOTES :
MANUFACTURERS STANDARD MUST APPROACH.
COLOR IS NOT REQUIRED. THE SELECTIONS SERVE ONLY TO INDICATE THE COLOR WHICH THE
INTENDED TO LIMIT SELECTIONS OF PRODUCTS. AN EXACT MATCH OF THE MANUFACTURERS
MANUFACTURERS' COLORS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY AND ARE NOT
USER AGENCY.
SELECTION OF INTERIOR PAINT AND FACTORY APPLIED COLORS SHALL BE APPROVED BY
SHALL BE WATERPROOF TYPE GWB.GWB FOR TOILETS, AND OTHER WET AREAS
1.
2.
3.
FT-1
OR APPROVED EQUAL
NON-SLIP, 300 x 300 x 8 THK
FG 7L67-1, MARON
DONGSEO, INUS
NON-SLIP CERAMIC FLOOR TILE
RT-1
VCB-1
OR APPROVED EQUAL
DARK BROWN, 100 HGT, 3THK
LG HAUSYS
VINYL COVE BASE
OR APPROVED EQUAL
RM4200, 2THK FOR STRINGER AND BASE
SOCR42, 3THK FOR TREAD/RISER,
CMR42, 3THK FOR FLOOR,
I-BADAK FLOORING SYSTEM
RUBBER TILE
GCWT-1
* GROUT COLOR FOR GCWT
OR APPROVED EQUAL
: MOLD & MILDEW RESISTANT, STAIN PROOF
ANTIQUE WHITE
OR APPROVED EQUAL
300 x 600 x 10 THK
LQR 1N92-1, GLOSS
DONGSEO, INUS
GLAZED CERAMIC WALL TILE
PT-1
OR APPROVED EQUAL
LATEX/SEMIGLOSS
NOROO NR7066
PAINT COLOR
ACST-1
PT-2
OR APPROVED EQUAL
LATEX/EGGSHELL
NOROO NR7066
PAINT COLOR
OR APPROVED EQUAL
WHITE
MC 3102
"KCC MITONE"
603MM x 603MM x 15MM THK
ACOUSTICAL CEILING TILE
* GROUT COLOR FOR GCWT
OR APPROVED EQUAL
: MOLD & MILDEW RESISTANT, STAIN PROOF
ANTIQUE WHITE
SCP
CFT
(AT EACH EXTERIOR BED ROOM ONLY)
OR APPROVED EQUAL
NON-SLIP, 210 x 600 x 8 THK
MSD 7544 OC
DONGSEO, INUS
NON-SLIP CERAMIC FLOOR TILE
MISC. MATERIAL/COLOR
ROOM NAMESROOM NOS
FLOOR BASE WALLS CEILING
REMARKS
FINISH COLOR FINISH COLOR FINISH COLOR FINISH COLOR HEIGHT
MAT'L
EXST
MAT'L
NEW
MAT'L
EXST
MAT'L
NEW
MAT'L
EXST
MAT'L
NEW
MAT'L
NEW
MAT'L
EXST
VCB VCB F.F VCB-1 PAINT PT-1
GAME ROOM
LAUNDRY
BULK STORAGE
STAIR-1
233 TV/LOUNGE ROOM
VCBPVCT VCBF.F. PVCT-1 F.F VCB-1 ACST ACST 2340VCT F.F ACST-1PAINT PT-1CMU/GWB -/GWB
CMT 2340F.F. - GWB* PAINT PT-2 GWB* : WATER RESISTANT TYPE- - - GCWT F.F. GWB
VCBPVCT VCBF.F. PVCT-1 F.F VCB-1 PAINT PT-2 2693VCT PAINT PT-1CMU - -
F.F.RT VCB F.F. PAINT PT-1 VAR * INCLUDE TREADS & RISERSVCT
CMT 2340F.F. - GWB* PAINT PT-2 GWB* : WATER RESISTANT TYPE- - - GCWT F.F.- GWB
VCBPVCT VCBF.F. PVCT-1 F.F VCB-1 ACST ACST 2340VCT F.F ACST-1PAINT PT-1
VCBPVCT VCBF.F. PVCT-1 F.F VCB-1 ACST ACST 2340VCT F.F ACST-1PAINT PT-1
ACST/- F.F/PAINT
/PT-2
ACST-1
CONC
ACST/
141, 142, 238
239, 338, 339
STAIR-2, STAIR-3
BALCONY143, 237, 337
CLEAN CONC VARCONC PAINT PT-1CLEAN - - - - - CONC - - PAINT PT-2
CONC 2900CONC PAINT PT-1- - - - - - PAINT PT-2CONC/EIFS
GCWTFT FT-1 GCWT-1
RT-1 RB RT-1 CMU/GWB -/GWB
STORAGE
FT FT-1 GCWT-1JANITOR CLOSET
GWB GWB
GWB GWB
GWB
VCBPVCT VCB
VCBPVCT VCB
PVCT
F.F.
F.F.
F.F.
F.F.
PVCT-1
PVCT-1
F.F.
F.F.
VCB-1
VCB-1
GWB
GWB*
PAINT
PAINT PT-2
2340 GWB* : WATER RESISTANT TYPE
VCT
VCT
CMT
VCT
PVCT-1 VCB VCB
GWB*
GCWT GCWT F.F.
GWB
GWB
F.F. VCB-1
VCBPVCT VCBF.F. PVCT-1 F.F. VCB-1 2340VCT
GWB PAINT PT-1 PT-2
GWB PAINTGWB* GWBGWB PAINT PT-1 PT-2
GCWT-1
2340GWB PAINTGWB* GWBGWB PAINT PT-1 PT-2
GWB PAINTGWB* GWBGWB PAINT PT-1 PT-2
GWB* : FIRE RETARDANT TYPE
GWB* : FIRE RETARDANT TYPE
GWB* : FIRE RETARDANT TYPE
GWB* : FIRE RETARDANT TYPE
FT FT-1
VCBPVCT VCBF.F. PVCT-1 F.F VCB-1 GWB ACST 2340VCT F.F ACST-1CMU - PAINT PT-1OFFICES
VCBPVCT VCBF.F. PVCT-1 F.F VCB-1 GWB ACST 2340VCT F.F ACST-1GWB PAINT PT-1CONFERENCE ROOM112
110, 130
122 SUPPLY ROOM
M./W. TOILET
128 CRYPTO VAULT
VEST VCBPVCT VCBF.F. PVCT-1 F.F VCB-1VCT CMU - ACST ACST 2340F.F ACST-1PAINT PT-1132, 133, 134
LOBBY, CORRIDOR136, 138, 139
236, 334, 336
201 THRU 232
301 THRU 332
PANTRY
BED ROOM
SERVICE AREA
TOILET
WALK IN CLOSET
GWB
CMU/GWB -/GWB*
CMU/GWB -/GWB* PAINT PT-1 CONC PAINT PT-2 2693-
2693PT-2PAINT-CONC
VCB VCB F.F VCB-1 CMU/GWB -/GWB* PAINT PT-1 CONC PAINT- PT-2 2693
CMT FT F.F. FT-1 - - - - - GCWT F.F. GCWT-1 GWB GWB* PAINT PT-2 2340 GWB* : WATER RESISTANT TYPE
VCT PVCT F.F. PVCT-1 VCB VCB F.F VCB-1 PAINT PT-1 CONC - PAINT PT-2 2693
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
KWON, CH
131420
121, 126, 127, 129, 116, 117, 119, 120, 111, 113, 114, 115, 106, 107, 108, 109, 101, 102, 103, 105, 137 MECH ROOM -- - - - - - 3300- - - -- CMU
104, 124, 125
COMM/SEC VAULT VCT PVCT F.F. PVCT-1 VCB VCB F.F VCB-1 GWB PAINT PT-1CMU/GWB CONC - PAINT PT-2 2693
123 TEL/COMM ROOM VCT PVCT F.F. PVCT-1 VCB VCB F.F VCB-1
CONC/GWB -
VCT PVCT F.F. PVCT-1 GWB* : FIRE RETARDANT TYPE
GWB* : FIRE RETARDANT TYPE
SCP ON CONCRETE WALL SURFACES
GWB* : FIRE RETARDANT TYPEVCT PVCT F.F. PVCT-1
SLM
OR APPROVED EQUAL
INDUSTRIAL SUB-FLOOR SCREED
CEMENTIOUS SELF SMOOTHING
SIKA FLOOR - LEVEL 25,
SIKA KOREA,
SELF LEVEL MORTAR
-/SLM -CLEAN/SLM
A-16
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
REMARKS
DOOR DIMENSION
WIDTH
MATERIAL
D1
DOOR
TYPE
DOOR
NOS.
ROUGH OPENING
WIDTH HEIGHT
HDW
SET
THICKHEIGHT NO (HR)
RATED
FIRE
LOUVERGLAZING
CUT
UNDER
FRAME
D2
D3
D4
D5
D6
D7
D8
D9
D10
DOOR
DOOR / WINDOW / LOUVER SCHEDULE HARDWARE SCHEDULE
D11
D12
D13
D14
D15
D16
D17
D18
A
B
STEEL STEEL 21331800 2200 1714 44.5 1
100X600
1) 2EA-
HDW-3
HDW-1
HINGES A8111 127x114, NRP
FLUSH BOLT L04081
ADJUSTABLE ASTRAGAL
EXIT DEVICE TYPE 2-FUNCTION 08
EXIT DEVICE TYPE 2-FUNCTION 01
THRESHOLD J36190
W2
W3
W1 L
1016610GLASS
10161016ALGLASS
GLASS AL 1220 1016 142- -
ASTRAGAL
- -WOOD STEEL 21331800 17142200 44.5 2
100X600
1) 2EA-
100X600
1) 1EA-
- -C STEEL STEEL 21331000 2200 914 44.5 3 -
100X600
1) 1EA-
- -C STEEL STEEL 21331000 2200 914 44.5 6 --
- -G WOOD 34.922001000 914 2133 8
GLASS
MIRROR
600X1220
- -F WOOD 2200 864950 2133 9 -STEEL 44.5 1/3
-H WOOD STEEL 2033800 2100 714 25.4 10 - -
-F WOOD STEEL 2033800 2100 714 34.9 11 - -19MM
- -D STEEL STEEL 21331000 2200 914 44.5 12 1-
-F STEEL 21331000 2200 914 44.5 13 --
- -C STEEL STEEL 21331000 2200 914 44.5 14 --
- -STEEL 44.522001000 914 2133 12 -D 1
-E STEEL STEEL 21331000 2200 914 44.5 16
100X600
1) 1EA-
19MM
-F STEEL 21331000 2200 914 44.5 15
100X600
1) 1EA-
WOOD
HINGES A8111 114x114
CLOSER C020212
DOOR STOP AND HOLDER L01371
DOOR STOP AND HOLDER L01371
HDW-4
LOCKSET F07
HDW-5
THRESHOLD J36190
HINGES A8111 114x114
CLOSER C020211
DOOR STOP AND HOLDER L01371
1 EXIT DEVICE TYPE 3-FUNCTION 08
HDW-6
THRESHOLD J36190
HINGES A8111 114x114
CLOSER C020211
1 DOOR VIEWER LO3221
HDW-7 HDW-8
DOOR PULL D8421
DOOR STOP D7461
D8271 & D8281
1 BOX TRACK SUPPORT
SEMI-AUTO CLOSING SYSTEM
DAIKEN HLS-80
* SOUNDPROOF WOODEN DOOR, STC-25 MIN
HDW-9
SOUND PROOF SEAL
AUTOMATIC DOOR BOTTOM
DOOR STOP L02141
HINGES A8112 114x1143
ROY 265 (FOR HEAD & JAMB)
CLOSER C020111
THRESHOLD J36190
THRESHOLD J32100
HDW-10
HINGES B01351
DEAD LOCK E0161
HDW-11
DOOR STOP L02161
HINGES A8112 114x1143
THRESHOLD MARBLE
HDW-12
THRESHOLD J32100
CLOSER C020211
HINGES A8111 114x114, NRP
DOOR STOP L02161
HDW-13 HDW-14 HDW-15
DOOR STOP L02141
HINGES A8111 114x1143
CLOSER C020111
THRESHOLD J32100
1 DOOR HOLDER L01381
AND HARDWARE SCHEDULE
DOOR, WINDOW SCHEDULE
ALL
L
* MINI-BLIND, TYPICAL INSULATED/LAMINATED GLASS
* MINI-BLIND, TYPICAL INSULATED/LAMINATED GLASS
* MINI-BLIND, TYPICAL INSULATED/LAMINATED GLASS LOCKSET F84 LEVER TYPE
LOCKSET F76 LEVER TYPE
LOCKSET F82 LEVER TYPE
DOOR STOP L02141
2 KICK PLATE J102, SST
1) INSULATED GLASS, 8.75T + 5 + 4
WEATHER STRIP & SEAL
1) INSULATED GLASS, 8.75T + 5 + 4
1 WEATHER STRIP & SEAL
1 KICK PLATE J102, SST
& KEY OVERRIDE
ELECTRONIC CARD
(LEVER TYPE HANDLE)
KEYED LOCKSET W/BATTERY
WEATHER STRIP & SEAL
1 KICK PLATE J301
WEATHER STRIP & SEAL1
DOOR PULL, J401
1 KICK PLATE J301
1 KICK PLATE J301
LOCKSET F86, LEVER TYPE
1 KICK PLATE J301
1 DEAD LOCK E0151
WOOD 3/4
- -F WOOD 22001000 2133 7 -STEEL 44.5
HDW-16
DOOR STOP L02141
HINGES A8111 114x1143
CLOSER C020111
THRESHOLD J36190
LOCKSET F75 LEVER TYPE
KICK PLATE J301
SLIDING DOOR LOCK
E STEEL STEEL 21332000 2200 1914 44.5 5 - --
300x300
2EA-
- -D STEEL STEEL 21331000 2200 914 44.5 3 1
100X600
1) 1EA-
1) 10THK TEMPERED GLASSSTEEL STEEL 21331000 2200 914 44.5 4
HINGES A8112 114X114
1 DOOR STOP LO2161
1 KICK PLATE J102, SST
CLOSER CO2011
THRESHOLD J321001
C
DOOR STOP LO2161
HINGES 8112 114X114
1 CLOSER CO2011
1 KICK PLATE J102, SST
THRESHOLD J321001
LOCKSET 4000-1, F-82
(LEVER TYPE HANDLE)
HINGES A8112 114X114
1 DOOR STOP LO2161
1 KICK PLATE J102, SST
CLOSER CO2011
THRESHOLD MARBLE1
PUSH PLATE
PULL PLATE1
19MM
THRESHOLD J36190
HINGES A8111 114x114
CLOSER C020211
DOOR STOP AND HOLDER L01371
LOCKSET F82 LEVER TYPE
WEATHER STRIP & SEAL
1 KICK PLATE J102, SST
WOOD
STEEL
3/4
SYSTEM, S-1974, CP CASEY
REPAIR BUILDING AND INSTALL SPRINKLER
KWON, CH
131420
D20 2235 1)1015 1) 1) 18 - - -METAL METAL 1) BY ARMORY DOOR MFR-
DOOR STOP L021611
HDW-18
D19 44.5METALJ - --2200 21001000 900METAL 3/417 1) FIRE RATED METAL DUTCH DOOR W/ 300 LENGTH SST SHELF
K
HDW-17
CLOSER CO20111
LOCKSET 1000-1 F042
(LEVER TYPE HANDLE)
1 THRESHOLD J32100
FLAT ASTRAGAL @ UPPER LEAF
KICK PLATE J102 SST
TO RELEASE THE DOOR HOLDER)
TO SMOKE DETECTOR OR FIRE ALARM SYS
(DOOR HOLDER SHALL BE CONNECTED
@UPPER LEAF (ELECTRIC POWER REQD)
TYPE C00011 (WALL MTD)
ELECTRO MAGNETIC DOOR HOLDER,
1 DOOR STOP L02161 @ LOWER LEAF
1) FIRE RATED GLASS, 10T
EXIT DEVICE TYPE 1-FUNCTION 081
- * SOUNDPROOF WOODEN DOOR, STC-25 MIN
1) FIRE RATED GLASS, 10T
1) FIRE RATED GLASS, 10T
1) INSULATED GLASS, 8.75T + 5 + 4
HINGES 5112 114X114, NRP
SOUNF PROOF SEAL1
THRESHOLD J36190
CLOSER C02011
HINGES A8111 114X114
HDW-2
2 DOOR STOP AND HOLDER L01371
KICK PLATE J102, SST
1 EXIT DEVICE TYPE 2-FUNCTION 08
EXIT DEVICE TYPE 2-FUNCTION 01
1) INSULATED GLASS, 8.75T + 5 + 4
WEATHER STRIP & SEAL1
ADJUSTABLE ASTRAGAL1
HDW-19
THRESHOLD J36190
CLOSER C02011
HINGES A8111 114X114
2 DOOR STOP AND HOLDER L01371
KICK PLATE J102, SST
1 EXIT DEVICE TYPE 2-FUNCTION 08
EXIT DEVICE TYPE 2-FUNCTION 01DOOR CDX-10
ELECTRO MECH LOCK FOR VAULT
A - -STEEL 21331800 17142200 44.5 19
100X600
1) 2EA-
-STEELD21
* HOLLOW CORE BLAST METAL DOOR
1) TEMPERED GLASS.
KEY BOX : WALL MOUNTED KEY BOX E83513.
COORDINATING WITH THE USER FOR APPROVAL BY COR.
THE CONTRACTOR SHALL SUBMIT MASTER KEYING CHART,
APPROVAL
AND WINDOW SCHEDULE AND DETAIL DRAWING TO COR FOR
CONTRACTOR SHOULD SUBMIT SHOP DRAWING FOR ALL DOOR
CONNECTED TO STRUCTURE WITH ANCHOR BOLT AND WELDING.
ALL EXTERIOR DOOR FRAME AND WINDOW FRAME SHOULD BE
AND UFC 4-010-01, PAG B-9 & 10, PARA B-3.1 THRU B-3.1.4
ALL EXTERIOR DOOR, GLAZED WINDOW: SEE SEPC SECTION 08391;
4.
5.
6.
8.
9.
7.
HEAT GAIN AND FIRERATED.
W…