0011227981

a. This is a Non-Work Plan Task Order for the follow ing Area I & II, MA IDIQ Contractors only.

Contract Number: W91QVN-18-D-0021, 0022, 0023, 0024, 0025, 0026, 0027, 0028, 0030, 0031, 0032, 0034, 0035, 0040,0042, 0043, 0044, 0045, 0046, 0047, 0048, 0049, 0050, 0051, 0052, 0162

b. If the contractor is unable to submit the proposal in response to this RFP, the contractor shall submit the “No-offer letter” by closing date and time specified in the solicitation

MR. SON, U KAP 315-755-3387

NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder".

10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS

NEGOTIATED

11-Sep-2018

(RFP)

(IFB)

X

CALL:

Repair Bldg# 1974, Area I

B. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)

See Item 7

2. TYPE OF SOLICITATION

SEALED BID

3. DATE ISSUED

9. FOR INFORMATION A. NAME

SOLICITATION

NSN 7540-01-155-3212 1442-101 STANDARD FORM 1442 (REV. 4-85)

Prescribed by GSA

FAR (48 CFR) 53.236-1(e)

11. The Contractor shall begin performance w ithin _______10 calendar days and complete it w ithin ________210 calendar days after receiving aw ard, X notice to proceed. This performance period is mandatory, X negotiable. (See _________________________Section F

12 A. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?

(If "YES," indicate within how many calendar days after award in Item 12B.)

YES X NO

13. ADDITIONAL SOLICITATION REQUIREMENTS:

A. Sealed offers in original and __________ copies to perform the w ork required are due at the place specified in Item 8 by ___________ local time ______________19 Sep 2018 (date). If this is a sealed bid solicitation, offers must be publicly opened at that time.

shall be marked to show the offeror's name and address, the solicitation number, and the date and time offers are due.

B. An offer guarantee is, X is not required.

C. All offers are subject to the (1) w ork requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.

D. Offers providing less than _______240 calendar days for Government acceptance after the date offers are due w ill not be considered and w ill be rejected.

SOLICITATION, OFFER,

AND AWARD

(Construction, Alteration, or Repair)

1. SOLICITATION NO.

IMPORTANT - The "offer" section on the reverse must be fully completed by offeror.

4. CONTRACT NO.

7. ISSUED BY CODE

411TH CONTRACTING SUPPORT BRIGADE, KOREA

SERVICES DIV, UNIT #15289

APO AP 96271

UNITED STATES

W91QVN

PAGE OF PAGES

1 OF

CODE

(Title, identifying no., date):

12B. CALENDAR DAYS

03:00 PM (hour)

Sealed envelopes containing offers

5. REQUISITION/PURCHASE REQUEST NO. 6. PROJECT NO.

131420

8. ADDRESS OFFER TO (If Other Than Item 7)

FAX:TEL: TEL: FAX:

W91QVN18R0262 24

20B. SIGNATURE

(REV. 4-85)STANDARD FORM 1442 BACK

TO SIGN

NSN 7540-01-155-3212

SOLICITATION, OFFER, AND AWARD (Continued) (Construction, Alteration, or Repair)

CODE FACILITY CODE

17. The offeror agrees to perform the w ork required at the prices specif ied below in strict accordance w ith the terms of this solicitation, if this offer is accepted by the Government in w riting w ithin ________ calendar days after the date offers are due.

the minimum requirements stated in Item 13D. Failure to insert any number means the offeror accepts the minimum in Item 13D.)

AMOUNTS SEE SCHEDULE OF PRICES

18. The offeror agrees to furnish any required performance and payment bonds.

19. ACKNOWLEDGMENT OF AMENDMENTS

(The offeror acknowledges receipt of amendments to the solicitation -- give number and date of each)

AMENDMENT NO.

DATE

20A. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN

OFFER (Type or print)

AWARD (To be completed by Government)

21. ITEMS ACCEPTED:

22. AMOUNT 23. ACCOUNTING AND APPROPRIATION DATA

24. SUBMIT INVOICES TO ADDRESS SHOWN IN ITEM

(4 copies unless otherwise specified)

CODE

(Insert any number equal to or greater than

20C. OFFER DATE

25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO

10 U.S.C. 2304(c) 41 U.S.C. 253(c)

CODE27. PAYMENT WILL BE MADE BY:26. ADMINISTERED BY

(Include ZIP Code)14. NAME AND ADDRESS OF OFFEROR 15. TELEPHONE NO. (Include area code)

See Item 14

(Include only if different than Item 14)16. REMITTANCE ADDRESS

30B. SIGNATURE

29. AWARD (Contractor is not required to sign this document.)

document and return _______ copies to issuing office.) Contractor agrees Your of f er on this solicitation, is hereby accepted as to the items listed. This award con-to f urnish and deliv er all items or perf orm all work, requisitions identif ied summates the contract, which consists of (a) the Gov ernment solicitation and on this f orm and any continuation sheets f or the consideration stated in this y our of f er, and (b) this contract award. No f urther contractual document is contract. The rights and obligations of the parties to this contract shall be necessary .

gov erned by (a) this contract award, (b) the solicitation, and (c) the clauses, representations, certif ications, and specif ications or incorporated by ref er-ence in or attached to this contract.

30A. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED 31A. NAME OF CONTRACTING OFFICER (Type or print)

30C. DATE

(Type or print)

TEL: EMAIL:

31B. UNITED STATES OF AMERICA 31C. AWARD DATE

BY

CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE

(Contractor is required to sign this28. NEGOTIATED AGREEMENT

(M ust be fully completed by offeror)OFFER

W91QVN18R0262

Section B - Supplies or Services and Prices

ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

0001 1 Job K Work

FFP

Repair barracks, building No. 1974 FOB: Destination

PURCHASE REQUEST NUMBER: 0011227981

PSC CD: Z2FC

NET AMT

0002 1 Job L Work

FFP

Repair barracks, building No. 1974 FOB: Destination

PURCHASE REQUEST NUMBER: 0011227981

PSC CD: Z2FC

0003 1 Lot Estimated cost for war hazard

FFP

is zero (0).

FOB: Destination

Section C - Descriptions and Specifications

TECHNICAL PROVISIONS - I

STATEMENT OF WORK

PROJECT NO TITLE LOCATION

131420 Repair barracks, building No. 1974 Camp Casey

1. DESCRIPTION: The work to be performed to repair barracks, building No. 1974 is described below and executed by one or more of the groups.

1.1. Work by Contractor: The contractor shall provide all labor, tools, equipment, supplies and any other resources necessary to accomplish the scope of work contained herein as indicated in the drawings and in accordance with the specifications.

1.2. Work by In-House Labor: Not applicable to this project.

1.3. Work by Troop Labor: Not applicable to this project.

2. PRINCIPAL FEATURES: This project includes the following principal features:

2.1. Schedule #I, Repair (K): All work shall be in accordance with the attached drawings and specifications.

2.1.1. Civil Work

2.1.1.1. Replace Asphalt Concrete (AC) pavement. (Drawing No. C-2, C-6)

2.1.1.2. Replace sidewalk. (Drawing No. C-2, C-4)

2.1.1.3. Paint parking line marking with 150mm thickness reflective white and safety zone with 300mm thickness reflective yellow,

2.1.1.4. Replace existing hydrant guard post with new. (Drawing No. C-2, C-4)

2.1.1.5. Remove vegetation and clean concrete ditch.

2.1.1.6. Restore solid sodding including top soil.

2.1.2. Architectural work

2.1.2.1. Replace existing floor tile with new Polyvinyl Chloride Tile (PVCT) including Vinyl Cove Base (VCB) as shown on floor plan and interior finish schedule. The existing concrete flooring shall be smooth, true, level plane with all defects such as rough or scaling concrete, low spots, high spots, painting, and uneven surface shall have been corrected for new flooring. Provide leveling concrete for existing concrete slab with government approval. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-8,A- 10,A-11,A-15)

2.1.2.2. Replace existing ceiling with new acoustical ceiling tile including metal suspension systems as shown on floor plan and interior finish schedule. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-8,A- 10,A-11,A-15)

2.1.2.3. Replace existing ceiling with new Gypsum Wall Board (GWB, Normal, water resistant or 'X' type) ceiling including ceiling suspension system as shown on floor plans and finish schedule.

(Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-8,A-10,A-11,A-15)

2.1.2.4. Replace existing all GWB walls with new including metal studs and sound proof insulations (Sound Transmission Coefficient (STC) 45) as shown on floor plans, sections and detail drawings.

(Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-8,A-10,A-11,A-15)

2.1.2.5. Replace existing Floor Tile (FT) and Glazed Ceramic Wall Tile (GCWT) with new including accessories, metal lath, mortar bed, and waterproofing in bathroom and shower room as shown on floor plans and detail drawings. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-9,A-10,A-11,A-12,A-14,A- 15)

2.1.2.6. Replace existing Fire Extinguisher Cabinet (FEC) with new as shown on new floor plans and detail drawing. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-10,A-11,A-13)

2.1.2.7. Block up and patch up where fire extinguisher cabinets are replaced as shown on floor plans and detail drawings.

2.1.2.8. Paint all interior surfaces including ceiling and wall as shown on floor plan and interior finish schedule and elevations.

2.1.2.9. Replace existing steel trench cover with new as shown on floor plan and detail drawing.

(Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-8)

2.1.2.10. Replace existing metal shelf including mop rack with new in janitor room as shown on floor plans and detail drawing. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-9,A-13)

2.1.2.11. Replace existing all doors and door frames with new including new hardware sets as shown on floor plans and door schedule. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-8,A-16,A-17)

2.1.2.12. Replace existing wooden sill for all windows with new as shown on floor plan, sections and detail drawing. (Natural color, Oak) (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-8,A-16,A-17)

2.1.2.13. Replace existing window horizontal mini blinds with news, fireproof type. (Drawing No. A- 1,A-2,A-3,A-4,A-5,A-6,A-8,A-16,A-17)

2.1.2.14. Replace existing windows including insect screen with new aluminum thermal breaker type blast windows including 8.75mm thickness clear laminated glass + 12mm thickness air space + 6mm thickness tinted low-e tempered glass (Solar Heat Gain Coefficient (SHGC): Max 0.4) as shown on floor plans and window schedule. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-8,A-16,A-17)

2.1.2.15. Replace existing kitchenette including base cabinet and upper cabinet as shown on floor plans, elevations and detail drawings. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-8,A-9,A-10,A-11,A- 13,A-14)

2.1.2.16. Replace existing Stainless Steel (SST) laundry shelves with new in each laundry room as shown on floor plan and detail. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-8,A-9,A-10,A-11,A-12)

2.1.2.17. Replace existing rubber tiles with new including tread, riser and stair base in stair-1 as shown on floor plans and interior finish schedule. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-8,A-10,A- 11,A-15)

2.1.2.18. Replace existing wooden hanger rails with new in each bed room as shown on floor plans and section. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-10)

2.1.2.19. Replace existing built up roof with new Ethylene Propylene Diene Monomer (EPDM) roofing system including insulation and treated wood nailer as shown on floor plans, sections and detail drawing. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-7,A-8)

2.1.2.20. Replace existing air intake louvers with new for fan coil units as shown on floor plan and detail drawing. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-7,A-13)

2.1.2.21. Paint all existing exterior exposed Exterior Insulation and Finish System (EIFS), Concrete Masonry Unit (CMU), metal, woods, concrete surfaces, stairwell, fascia, soffit, Korea roof tiles, and other components of exterior surface as shown on floor plans, elevations and finish schedule.

2.1.2.22. Replace existing vanity cabinets with new in each toilet as shown on floor plans and detail drawings. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-9,A-10,A-12)

2.1.2.23. Replace existing all toilet accessories with new as shown on floor plan and detail drawings.

(Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-9,A-10,A-12)

2.1.2.24. Replace existing plexi-info holder and card holder with new as shown on signage schedule and detail drawings. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-10,A-18)

2.1.2.25. Replace existing all access doors on wall and ceiling with new. (Drawing No. A-1,A-2,A- 3,A-4,A-5,A-6,A-9,A-10)

2.1.2.26. Replace existing wooden shelves and rods with new in each walk-in closet as shown on floor plans and detail drawings. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-10,A-11,A-13)

2.1.2.27. Replace existing wooden shelf cabinets with new in each walk-in closet as shown on floor plans and detail drawings. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-10,A-11,A-13)

2.1.2.28. Replace existing wooden shelves with new in each pantry as shown on floor plans and detail drawings. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-10,A-11)

2.1.2.29. Replace existing pipe chases and pipe cover with new CMU, waterproof or ‘X’ type of GWB in each rooms for new mechanical piping system and duct as per floor plans, sections and detail drawings. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-8,A-9,A-10,A-11)

2.1.2.30. Replace existing concrete slab with new for replacing mechanical piping work on 1st floor.

(Drawing No. A-1,A-2,A-8,A-9,A-10,A-11)

2.1.2.31. Replace interior and exterior signages with new for all rooms as shown on floor plan, elevations and signage schedule. (Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-18)

2.1.2.32. Paint existing metal storage bins and replace existing plywood with new 18mm thickness plywood plastic laminated film as shown on floor plans.

2.1.2.33. Remove existing CMU wall with exterior insulation finish system for blast doo, and clean and refinish concrete floor as shown on floor plans, section and detail drawing.

2.1.2.34. Replace existing exterior CMU wall with new including C-channel, 150mm thickness insulation, cement board, EIFS finish coat only as shown on floor plan, section and detail drawing.

(Drawing No. A-1,A-2,A-3,A-4,A-5,A-6,A-8,A-10)

2.1.2.35. Replace existing ceramic floor tiles with new including accessories and SST transitional strip at each bed room exterior door as shown floor plans, section and detail drawing. (Drawing No.

A-1,A-2,A-3,A-4,A-5,A-6,A-8,A-10)

2.1.2.36. Block up existing door opening with 200mm thickness CMU including re-bar and EIFS as shown on floor plan and elevation.

2.1.2.37. Cut and open existing CMU wall with EIFS finish to replace existing window with new in Roka-1 office as shown on floor plan and elevation.

2.1.2.38. Repair damaged concrete floors on 2nd and 3rd floor balconies as shown on picture.

2.1.2.39. Replace existing stone bed including gravel with new in front of building as shown on picture. (Drawing No. A-1,A-2,A-7)

2.1.2.40. Replace existing window security bars with painting at room No. 109, 112, 126, and 124 with new as shown on floor plan and elevation. (Drawing No. A-1,A-2,A-7)

2.1.3. Mechanical Work

2.1.3.1. Heating, Ventilating, and Air Conditioning (HVAC) system

2.1.3.1.1. Replace existing fan coil units, outside air intake boxes, control, and associated piping with new. (Drawing No. M-2, M-3, M-4, M-5, M-6, M-8)

2.1.3.1.2. Replace existing hot and chilled water piping with insulations, drain piping, and associated accessories with new. (Drawing No. M-2, M-4, M-5, M-6, M-7, M-9)

2.1.3.1.3. Replace existing exhaust fans, wind driven rotary turbine ventilator, and control with new.

(Drawing No. M-2, M-3, M-6, M-7, M-8)

2.1.3.1.4. Replace existing bathroom exhaust fans and ducts with new. (Drawing No. M-2, M-3, M-4, M-5, M-6)

2.1.3.1.5. Replace existing finned tube radiators and range hoods including duct with new. (Drawing No. M-2, M-3, M-4, M-5, M-6)

2.1.3.1.6. Replace existing air separator, expansion tank, and electric unit heater with new. (Drawing No. M-2, M-3, M-4, M-5, M-7)

2.1.3.1.7. Replace existing split air conditioning unit, chilled and hot water circulation pumps, and control with new. (Drawing No. M-2, M-3, M-4, M-6)

2.1.3.1.8. Replace existing outside air intake louver including motorized outside air damper and Carbon Monoxide (CO) detection system for Mechanical room with new. (Drawing No. M-2, M-4, M- 7, M-8)

2.1.3.1.9. All mechanical systems shall be tested, adjusted, and balanced by the contractor in strict accordance with applicable sections of division 15 - mechanical O&MA standard technical specifications for miscellaneous projects, Korea. The HVAC Testing, Adjusting, and Balancing (TAB) report shall be submitted to the project COR for government review and approval.

2.1.3.2. Plumbing system

2.1.3.2.1. Replace existing domestic hot and cold water piping including insulations, water hammer arrester schedule, and associated accessories with new. (Drawing No. M-2, M-10, M-11, M-12)

2.1.3.2.2. Replace existing sewer piping, vent piping, floor drain, and cleanout with new. (Drawing No. M-2, M-13, M-14,M-15)

2.1.3.2.3. Replace existing plumbing fixtures, water meter, and associated piping with new. (Drawing No. M-2, M-10, M-11, M-12)

2.1.3.2.4. Replace existing sink and valve box in the laundry room with new. (Drawing No. M-2, M- 10, M-11, M-12)

2.1.3.2.5. Replace existing domestic hot water storage tank, domestic hot water circulation pump, domestic hot water re-circulation pump, control, and associated accessories with new. (Drawing No.

M-2, M-3, M-7, M-9)

2.1.4. Electrical Work

2.1.4.1. Replace existing lighting fixtures, exit replace existing lighting fixtures, exit controlled lighting contactor, wires and conduits with new. (Drawing No. E-1,E-2,E-3,E-4,E-5)

2.1.4.2. Replace existing receptacles and cover plates, circuit breakers indicated in drawing, power wiring and conduits with new. (Drawing No. E-1, E-6, E-7, E-10, E-11,E-12)

2.1.4.3. Replace existing magnetic motor starters, manual motor starters, junction boxes, safety switches, control system, wires and conduits for mechanical system with new. (Drawing No. E-1, E- 10, E-11, E-12)

2.1.4.4. Replace fire alarm control system with new addressable fire alarm control and mass notification system panel, manual pull station, smoke detector and relay module, building transmitter, antenna, visual signal strobes, microphone, speaker device, local operating console, and associated wiring and conduit. (Drawing No. E-1, E-13, E-14, E-15)

2.1.4.5. Replace existing telephone terminal board, equipment rack and accessories, outlets including cover plates, and associated wiring and conduit with new. (Drawing No. E-1, E-16, E-17, E-18, E-19)

2.1.4.6. Replace existing CATV cabinets and pull-boxes, outlets including cover plates, and associated wiring and conduit with new. (Drawing No. E-1, E-18, E-19, E-20)

2.1.4.7. Remove and reinstall existing CCTV cameras and monitoring system with associated wiring and conduit.

2.2. Schedule #II, New Construction (l): all work shall be in accordance with the attached drawings and specifications.

2.2.1. Civil Work

2.2.1.1. Install 150mm diameter (PVC) water line including Post Indicator Valve (PIV).

2.2.1.2. Construct concrete curb.

2.2.1.3. Construct bike shed.

2.2.1.4. Construct 2ea surface inlet including 250mm diameter PVC drain pipe.

2.2.1.5. Install 12ea concrete wheel stop.

2.2.2. Mechanical Work

2.2.2.1. Fire protection

2.2.2.1.1. Install new sprinkler system.

TECHNICAL PROVISIONS - II

TECHNICAL DETAIL SPECIFICATIONS

GENERAL: The specification sections listed below are applicable to this project. The specifications are from the “Standard Technical Specifications for O&MA Projects, Korea, Revision 1” (2014 OMA SPECS, REVISION 1), dated 20151030, located on the http://www.usfk.mil/Portals/105/Documents/Contracting/NewContract/2014-OMA-SPECS_REVISION- 1.pdf. The electronic version of the specifications is Acrobat® PDF format and can be read with the Acrobat Reader® software.

Changes to the Standard Technical Detail Specifications: None

TECHNICAL PROVISIONS - III

SPECIAL CONDITIONS

1. Material Approval Submittal: The contractor shall submit a shop drawing submittal schedule and the material approval request with all supporting documents to the COR within 7 days after receipt of NTP.

2. The contractor shall have personnel on site for the fire alarm work upon Government's direction, who are certified by the National Institute for Certification in Engineering Technologies (NICET) Level III or equivalent. Equivalent Certificate in Korea is the following which is issued by the Human Resource Development Service of Korea. If the contractor doesn’t have personnel who are certified by NICET, the contractor shall have personnel who are certified for (1) below.

(1) Engineer Fire Fighting Facilities - Electrical (소방설비기사 -전기)

3. Environmental Requirements in Contract

The Contractor shall perform work consistent with the relevant policy and objectives identified in Installation’s Environmental Management System (EMS). The Contractor shall perform work in a manner that conforms to all appropriate Environmental Management Programs and Operational Controls identified by Installation’s EMS, including pollution prevention, waste reduction, energy use, and natural resource protection. The Contractor shall provide monitoring and measurement information as necessary for the organization to address environmental performance relative to the environmental, energy, and transportation management goals. In addition, the Contractor shall advise their employees of their roles and responsibilities identified by the EMS and how these requirements affect their work performed under this contract. The Contractor is responsible for ensuring that the Contractor and any persons involved in the supervision or performance of the contract complete all required Environmental training.

In the event of any environmental nonconformance or noncompliance associated with the contracted services, the contractor shall take corrective and/or preventative actions. In the event of any noncompliance with any federal, state, or local environmental law, regulation or requirement, the Contractor shall immediately respond by taking all appropriate corrective actions and notifying the Contracting Officer’s Representative (COR) and the Environmental Office. For any nonconformance with the EMS, the Contractor shall take corrective action and initiate further preventative action, as required by the Environmental Office.

All on-site contractor personnel shall complete necessary safety and environmental training specified for the type of work conducted on-site. Upon contract award, the COR will notify the EMS Manager to arrange Environmental training for appropriate staff.

Additionally, when ordering supplies for use on Installation, all contractor personnel must favor energy-efficient, recycled or reclaimed material whenever practicable.

The responsibilities of all contractor personnel include:

(1) Comply with all applicable environmental laws, regulations and installation environmental policies.

(2) Control and prevent spills or hazardous substances releases IAW installation Spill Prevention

Plan.

(3) Ensure dust, debris, materials, trash, etc., do not become air borne and travel off the project site.

(4) Do not remove, cut, deface, injure, or destroy land resources including trees, shrubs, vines, topsoil and land forms without approval, except in areas indicated on the drawings or specified to be cleared.

(5) Monitor all water areas affected by construction activities to prevent pollution of surface and ground waters. Do not apply toxic or hazardous chemicals to soil or vegetation unless otherwise indicated.

(6) Open burning is prohibited on the Government premises IAW installation environmental policy.

(7) Participate in installation’s recycling program.

(8) Reducing the amount of hazardous material and/or solvent used by purchasing fewer hazardous materials and by increasing the use of products with recycled content. Spills of hazardous or toxic materials must be immediately reported to the Contracting Officer and the Environmental Office.

Storage, describing, packaging, labeling, marking and placarding of hazardous waste and hazardous material IAW applicable environmental laws, regulations and local environmental policies. Transport hazardous waste off Government property and dispose of it in compliance with National, Provincial, and/or Local requirements for solid waste disposal.

(9) Reducing the amount of solid waste from construction and demolition debris, and scrap metal sent to municipal and rubble landfills by reducing, reusing, and recycling. Handling, storage, and disposal of solid waste must be conducted to prevent contamination. Transport solid waste off Government property and dispose of it in compliance with National, Provincial, and/or Local requirements for solid waste disposal.

(10) Conserving energy and water usage by turning off lights and equipment when not in use and using only the necessary amount of water needed to complete the required tasks. Continuous conservation of our natural resources is a must.

(11) When potential cultural or historic items are inadvertently found during construction activities, immediately cease activities in the vicinity of the discovery and report the findings to the Environmental Office.

(12) Participate in installation’s Integrated Pest Management (IPM) program whenever practicable.

(13) Minimize interference with disturbance to, and damage to fish, wildlife, and plants including their habitat.

4. CONTRACT REQUIREMENTS PACKAGE ANTITERRORISM/OPERATIONS SECURITY REVIEW

COVER SHEET

After Notice to process is issued, COR shall take following action, Section IV. Standard Contract Language/Contract Clause Applicability and/or Additional SOW Language.

A. Access and general protection/security policy and procedures. This standard language is for contractor employees with an area of performance within Army controlled installation, facility, or area.

Contractor and all associated sub-contractors employees shall provide all information required for background checks to meet installation access requirements to be accomplished by installation Provost Marshal Office, Director of Emergency Services or Security Office. Contractor workforce must comply with all personal identity verification requirements (FAR clause 52.204-9, Personal Identity Verification of

Contractor Personnel) as directed by DOD, HQDA and/or local policy. In addition to the changes otherwise authorized by the changes clause of this contract, should the Force Protection Condition (FPCON) at any individual facility or installation change, the Government may require changes in contractor security matters or processes.

A-a. For contractors that do not require CAC, but require access to a DoD facility or installation. Contractor and all associated sub-contractors employees shall comply with adjudication standards and procedures using the National Crime Information Center Interstate Identification Index (NCIC-III) and Terrorist Screening Database (TSDB) (Army Directive 2014-05/AR 190-13), applicable installation, facility and area commander installation/facility access and local security policies and procedures (provided by government representative), or, at OCONUS locations, in accordance with status of forces agreements and other theater regulations.

B. For Contract Requiring Performance or Delivery in a Foreign Country, DFARS Clause 252.225- 7043, Antiterrorism/Force Protection for Defense Contractors Outside the US. The clause shall be used in solicitations and contracts that require performance or delivery in a foreign country. This clause applies to both contingencies and non-contingency support. The key AT requirement is for non-local national contractor personnel to comply with theater clearance requirements and allows the combatant commander to exercise oversight to ensure the contractor’s compliance with combatant commander and subordinate task force commander policies and directives.

Section F - Deliveries or Performance

CLAUSES INCORPORATED BY FULL TEXT

52.211-10 COMMENCEMENT, PROSECUTION, AND COMPLETION OF WORK (APR 1984)

The Contractor shall be required to (a) commence work under this contract within 10 calendar days after the date the Contractor receives the notice to proceed, (b) prosecute the work diligently, and (c) complete the entire work ready for use not later than 210 calendar days after notice to proceed (NTP) is issued.

* The time stated for completion shall include final cleanup of the premises.

(End of clause)

Section J - List of Documents, Exhibits and Other Attachments

LIST OF APPLICABLE CONTRACT DRAWINGS

GENERAL: The work shall conform to the following contract drawings and OMA standard detail drawings, 2014 (dated 30 November 2015), issued by the Department of the Army, Installation Management Agency, Korea Region Office and located on http://www.usfk.mil/Portals/105/Documents/Contracting/NewContract/STANDARD-DETAIL-DRAWINGS- FOR-OMA-PROJECTS-KOREA_20151130.pdf, all of which form a part of the specifications.

Ring No. Sheet No. Description Date

1 T-1 TITLE SHEET 10 JUL 18

CIVIL

2 C-1 LOCATION PLAN AND GENERAL NOTES 10 JUL 18

3 C-2 SITE LAYOUT PLAN AND SCOPE OF WORK 10 JUL 18

4 C-3 BIKE SHED PLAN, SECTION & DETAILS 10 JUL 18

5 C-4 MISC. DETAILS-1 10 JUL 18

6 C-5 MISC. DETAILS-2 10 JUL 18

7 C-6 MISC. DETAILS-3 10 JUL 18

ARCHITECTURAL

8 A-1 1ST FLOOR PLAN-1 10 JUL 18

9 A-2 1ST FLOOR PLAN-2 AND GENERAL NOTES 10 JUL 18

10 A-3 2ND FLOOR PLAN-1 10 JUL 18

11 A-4 2ND FLOOR PLAN-2 AND SCOPE OF WORK 10 JUL 18

12 A-5 3RD FLOOR PLAN-1 10 JUL 18

13 A-6 3RD FLOOR PLAN-2 AND DETAILS 10 JUL 18

14 A-7 ELEVATIONS AND PICTURES 10 JUL 18

15 A-8 GENERAL CROSS SECTION & DETAILS 10 JUL 18

16 A-9 ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS-

10 JUL 18

17 A-10 ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS-

10 JUL 18

18 A-11 WALL SECTIONS 10 JUL 18

19 A-12 MISC DETAILS-1 10 JUL 18

20 A-13 MISC DETAILS-2 10 JUL 18

21 A-14 CABINET DETAILS 10 JUL 18

22 A-15 INTERIOR, EXTERIOR FINISH SCHEDULE AND

MATERIAL & COLOR SCHEDULE

10 JUL 18

23 A-16 DOOR, WINDOW SCHEDULE AND HARDWARE

SCHEDULE

10 JUL 18

24 A-17 DOOR, WINDOW ELEVATIONS, NOTES AND DETAILS 10 JUL 18

25 A-18 SIGNAGES SCHEDULE 10 JUL 18

MECHANICAL

26 M-1 MECHANICAL MATERIAL INDICATIONS & SYMBOLS

AND ABBREVIATIONS

10 JUL 18

27 M-2 GENERAL NOTES & SCOPE OF WORK 10 JUL 18

28 M-3 MECHANICAL EQUIPMENT SCHEDULE 10 JUL 18

29 M-4 1ST FLOOR HVAC PLAN AND NOTES 10 JUL 18

30 M-5 2ND FLOOR HVAC PLAN AND NOTES 10 JUL 18

31 M-6 3RD FLOOR HVAC PLAN AND NOTES 10 JUL 18

32 M-7 MECHANICAL ROOM ENLARGED PLAN, ELEC. UNIT

HEATER CONTROL AND NOTES

10 JUL 18

33 M-8 FAN COIL UNIT CONTROL DIAGRAM, MECH RM WALL

FAN CONTROL DIAGRAM, AND CO DETECTION

SYSTEM

10 JUL 18

34 M-9 CHILLED/HOT WATER PIPING SYSTEM DIAGRAM

AND SEQUENCE OF OPERATION

10 JUL 18

35 M-10 COLD AND HOT WATER PIPING PLAN (1ST & 2ND

FLOOR) AND NOTES

10 JUL 18

36 M-11 COLD AND HOT WATER PIPING PLAN (3RD FLOOR),

PLUMBING FIXTURE SCHEDULE, WATER HAMMER

ARREST AND NOTES

10 JUL 18

37 M-12 ENLARGED PLAN FOR TYPE "A", "B", "C" AND

ENLARGED PLAN

10 JUL 18

38 M-13 SEWER PIPING PLAN (1ST & 2ND FLOOR) AND

NOTES

10 JUL 18

39 M-14 SEWER PIPING PLAN (3RD FLOOR), ENLARGED

PLAN AND NOTES

10 JUL 18

40 M-15 SEWER AND VENT PIPING ENLARGED PAITIAL PLAN 10 JUL 18

41 M-16 CONTROL DIAGRAM 10 JUL 18

42 M-17 FIRE PROTECTION LEGEND & ABBREVIATION

AUTOMATIC FIRE SUPPRESSION GENERAL NOTES

AND SPRINKLER Q'TY LIST

10 JUL 18

43 M-18 FIRE PROTECTION CLASSIFICATION PLAN (1ST &

2ND FLOOR)

10 JUL 18

44 M-19 FIRE PROTECTION CLASSIFICATION PLAN (3RD

FLOOR), MECH ROOM FIRE PROTECTION PIPING

PARTIAL PLAN AND FIRE PROTECTION

REQUIREMENTS

10 JUL 18

45 M-20 1ST FLOOR FIRE PROTECTION PIPING PLAN 10 JUL 18

46 M-21 2ND FLOOR FIRE PROTECTION PIPING PLAN 10 JUL 18

47 M-22 3RD FLOOR FIRE PROTECTION PIPING PLAN 10 JUL 18

48 M-23 DETAILS-1 10 JUL 18

49 M-24 DETAILS-2 10 JUL 18

50 M-25 DETAILS-3 10 JUL 18

51 M-26 DETAILS-4 10 JUL 18

52 M-27 DETAILS-5 10 JUL 18

ELECTRICAL

53 E-1 LEGEND, GENERAL NOTES AND SCOPE OF WORK 10 JUL 18

54 E-2 NEW 1ST & 2ND FLOOR LIGHTING PLAN 10 JUL 18

55 E-3 NEW 3RD FLOOR LIGHTING PLAN & MODULE

LIGHTING PLAN

10 JUL 18

56 E-4 LIGHTING FIXTURE DETAILS 10 JUL 18

57 E-5 LIGHTING FIXTURE SCHEDULE & NEW EXTERIOR

LIGHTING CONTROL DIAGRAM

10 JUL 18

58 E-6 NEW 1ST & 2ND FLOOR POWER PLAN 10 JUL 18

59 E-7 NEW 3RD FLOOR POWER PLAN & MODULE POWER

PLAN

10 JUL 18

60 E-8 NEW 1ST & 2ND FLOOR FAN COIL UNIT

POWER/CONTROL PLAN

10 JUL 18

61 E-9 NEW 3RD FLOOR FAN COIL UNIT POWER/CONTROL

PLAN

10 JUL 18

62 E-10 MECH ROOM, 2ND LAUNDRY ROOM ENLARGED

PLAN

10 JUL 18

63 E-11 EXIST PANELBOARD CONN DIAGRAMS-1 10 JUL 18

64 E-12 EXIST PANELBOARD CONN DIAGRAMS-2 10 JUL 18

65 E-13 NEW 1ST & 2ND FLOOR FIRE ALARM

CONTROL/MASS NOTIFICATION SYSTEM PLAN

10 JUL 18

66 E-14 NEW 3RD FLOOR FIRE ALARM CONTROL/MASS

NOTIFICATION SYSTEM PLAN

10 JUL 18

67 E-15 NEW FIRE ALARM/MASS NOTIFICATION SYSTEM

DIAGRAM

10 JUL 18

68 E-16 NEW 1ST FLOOR LAN/TEL PLAN 10 JUL 18

69 E-17 TELECOMMUNICATION SYSTEM DIAGRAM FOR 1ST

FLOOR

10 JUL 18

70 E-18 NEW 1ST & 2ND FLOOR CATV/CCTV/TELEPHONE

PLAN

10 JUL 18

71 E-19 NEW 3RD FLOOR CATV/CCTV/TELEPHONE PLAN 10 JUL 18

72 E-20 CATV SYSTEM DIAGRAM 10 JUL 18

SUBMITTAL REGISTER

NOTE 1. See the attachment.

NOTE 2. The Submittal Register in Section J above, identifies the documentation that will be made available for approval and review by the Government in the performance of this task order. It is the contractor's responsibility that this data is in compliance with the corresponding OMA specification that is referenced.

Section K - Representations, Certifications and Other Statements of Offerors

52.203-2 CERTIFICATE OF INDEPENDENT PRICE DETERMINATION (APR 1985)

(a) The offeror certifies that --

(1) The prices in this offer have been arrived at independently, without, for the purpose of restricting competition, any consultation, communication, or agreement with any other offeror or competitor relating to –

(i) Those prices,

(ii) The intention to submit an offer, or

(iii) The methods of factors used to calculate the prices offered:

(2) The prices in this offer have not been and will not be knowingly disclosed by the offeror, directly or indirectly, to any other offeror or competitor before bid opening (in the case of a sealed bid solicitation) or contract award (in the case of a negotiated solicitation) unless otherwise required by law; and

(3) No attempt has been made or will be made by the offeror to induce any other concern to submit or not to submit an offer for the purpose of restricting competition.

(b) Each signature on the offer is considered to be a certification by the signatory that the signatory --

(1) Is the person in the offeror's organization responsible for determining the prices offered in this bid or proposal, and that the signatory has not participated and will not participate in any action contrary to subparagraphs (a)(1) through (a)(3) of this provision; or

(2) (i) Has been authorized, in writing, to act as agent for the following principals in certifying that those principals have not participated, and will not participate in any action contrary to subparagraphs (a)(1) through (a)(3) of this provison ______________________________________________________ (insert full name of person(s) in the offeror's organization responsible for determining the prices offered in this bid or proposal, and the title of his or her position in the offeror's organization);

(ii) As an authorized agent, does certify that the principals named in subdivision (b)(2)(i) above have not participated, and will not participate, in any action contrary to subparagraphs (a)(1) through (a)(3) above; and

(iii) As an agent, has not personally participated, and will not participate, in any action contrary to subparagraphs (a)(1) through (a)(3) of this provision.

(c) If the offeror deletes or modifies subparagraph (a)(2) of this provision, the offeror must furnish with its offer a signed statement setting forth in detail the circumstances of the disclosure.

(End of Provision)

252.209-7999 Representation by Corporations Regarding an Unpaid Delinquent Tax Liability or a Felony Conviction under any Federal Law

REPRESENTATION BY CORPORATIONS REGARDING AN UNPAID DELINQUENT TAX LIABILTIY

OR A FELONY CONVICTION UNDER ANY FEDERAL LAW (DEVIATION 2012-00004) (JAN 2012)

(a) In accordance with sections 8124 and 8125 of Division A of the Consolidated Appropriations Act, 2012, (Pub. L. 112-74) none of the funds made available by that Act may be used to enter into a contract with any corporation that-

(1) Has any unpaid Federal tax liability that has been assessed, for which all judicial and administrative remedies have been exhausted or have lapsed, and that is not being paid in a timely manner pursuant to an agreement with the authority responsible for collecting the tax liability, where the awarding agency is aware of the unpaid tax liability, unless the agency has considered suspension or debarment of the corporation and made a determination that this further action is not necessary to protect the interests of the Government.

(2) Was convicted of a felony criminal violation under any Federal law within the preceding 24 months, where the awarding agency is aware of the conviction, unless the agency has considered suspension or debarment of the corporation and made a determination that this action is not necessary to protect the interests of the Government.

(b) The Offeror represents that –

(1) It is ( ) is not ( ) a corporation that has any unpaid Federal tax liability that has been assessed, for which all judicial and administrative remedies have been exhausted or have lapsed, and that is not being paid in a timely manner pursuant to an agreement with authority responsible for collecting the tax liability,

(2) It is ( ) is not ( ) a corporation that was convicted of a felony criminal violation under a federal law within the preceding 24 months.

(End of provision)

5152.204-4032 REPRESENTATIONS AND CERTIFICATIONS

(a) SUBCONTRACTING:

If the offeror contemplates subcontracting, it must obtain prior written approval of subcontractor from the PCO or ACO, and list below: (1) the names and addresses of the subcontractor(s), (2) the type of subcontracting, and (3) the estimated price for each subcontract.

(b) AFFILIATED OFFERORS:

(1) Business concerns are affiliates of each other when, either directly or indirectly, one concern controls or has the power to control the other, or a third party controls or has the power to control both.

(2) Each offeror shall furnish, below, the following information:

(i) Whether the offeror has any affiliates;

(ii) The names and addresses of all affiliates of the offeror; and

(iii) The names and addresses of all persons and concerns exercising control or ownership of the offeror and any or all of its affiliates, and whether they are common officers, directors, stockholders holding controlling interest, or otherwise.

AFFILIATED CONCERNS. : (Name, location and, in detail, controlling interest in each)

(c) PRINCIPAL OWNER(S) OR STOCKHOLDER(S):

Each offeror shall list below the name(s) and address(es) of the principal owner(s) or stockholder(s) of the company and percentage of ownership. If a major portion is publicly traded and/or otherwise widely distributed, state that, with the percentage so affected.

(d) STANDARDS OF CONDUCT CERTIFICATION:

This is to certify that, to the best of my knowledge and belief, except as described below, no representative of this firm who deals with US Government employees on any aspect of this procurement is a former US Government employee, to include former US military personnel. I understand that this certification is continuing in nature and places a duty on me and my firm to notify the Contracting Officer of any additional individual(s) who fit the above description prior to the individual's assuming duties.

(i) Name ______________________________________________ Former rank/grade ____________________________________ Last US Government position ___________________________

(ii) Name ______________________________________________ Former rank/grade ____________________________________ Last US Government position ___________________________

(iii) Name ______________________________________________ Former rank/grade ____________________________________ Last US Government position ___________________________

Firm ____________________________________________________ Name _____________________________________________________ Signature __________________________________________________

Title _____________________________________________________ Date of Execution ____________________________________________

(e) TAXES:

(1) References:

(i) Contract clause entitled "FAR 52.229-06 Taxes—Foreign Fixed-Price Contracts (Jan 1991)."

(ii) US-ROK Status of Forces Agreement (SOFA), Articles IX and XVI.

(iii) ROK Customs Law, Law No. 1976, promulgated on 29 November 1967, as amended.

(iv) ROK Value Added Tax Law, Law No. 2934, promulgated on 22 December 1976 (effective date 1 July 1977), as amended.

(v) ROK Special Excise Tax Law, Law No. 2935, promulgated on 22 December 1976 (effective date 1 July 1977), as amended.

(2) Contractor shall state the types and estimated amount of taxes that would normally apply to such transactions but are excluded from this proposal.

(i) Customs Tax (except for ROK MND-funded contracts or delivery orders):

Name Number Cost/Unit of Item of Units w/o Tax % of Tax Tax/Unit Tax Total

This item will be imported specifically for this contract? Yes _____ No _____

(ii) Special Excise Tax:

Name Number Cost/Unit of Item of Units w/o Tax % of Tax Tax/Unit Tax Total

Name of item manufacturer

(iii) Value Added Tax (VAT):

Input VAT on materials purchased for this contract. 10% _____ Input VAT on transportation leased/rented for this contract.10% _____ Input VAT on equipment leased/rented for this contract. 10% _____ Input VAT on services purchased for this contract. 10% _____ Output VAT on total contract amount. 10% _____

(iv) Special Excise (Petroleum) Tax:

No. of U/P Liters w/o Tax Tax/Unit Total Tax Amount Regular Gasoline ________ (L) ________ w________ w_____________ Premium Gasoline ________ (L) ________ w________ w_____________ Diesel ________ (L) ________ w________ w_____________ Other ________ (L) ________ w________ w_____________

(v) Education Tax.

(3) Name of the oil company from which POL products will be purchased:

Oil Company: _________________________________________ (Name only)

(4) I certify by this submission that all supplies and services to be purchased for this contract have been proposed exclusive of Value Added Tax, applicable Customs Tax (except ROK MND-funded contracts and delivery orders), Special Excise Tax, and Education Tax.

Signed (Chop)

(f) CERTIFICATIONS AND REPRESENTATIONS

By submitting an offer, each offeror agrees to be bound by all certifications and representations in this solicitation.

The Government reserves the right to require any and all certifications and representations to be completed and signed in hard copy by the successful offeror prior to contract award. Failure of an offeror to complete the certifications and representations within the time directed by the Contracting Officer may result in a determination that the contractor is not a responsible offeror for this acquisition.

Section L - Instructions, Conditions and Notices to Bidders

SECTION L

1. GENERAL INSTRUCTIONS FOR PREPARATION OF PROPOSAL:

The Government intends to award without discussion, but reserves the right to conduct discussions if deemed necessary and to establish a competitive range for efficiency in accordance with FAR 52.215-1(f)(4).

Offeror(s) may, at the discretion of the Government, be asked to provide more information and clarification regarding their proposals. The Government may make a final determination as to whether an offer is acceptable or unacceptable solely based on the proposals as submitted, without requesting any further information. However, if it is deemed necessary the Government may, at its sole discretion, request additional information clarifying but not substantially changing any proposal as submitted.

2. SUBMISSION OF PROPOSAL:

i) FBO SUBMISSION REQUIRED: Offers shall be submitted to the Federal Business Opportunities (FBO) website (https://www.fbo.gov/), or if FBO is not available, email to ukap.son1.ln@mail.mil with the evidence document such as screen shot. The FBO unavailability is limited to only FBO server problem not individual failure/problem.

All questions should be emailed to ukap.son1.ln@mail.mil within five (5) days after the solicitation is issued.

ii) CLOSING DATE: The electronic offer shall be submitted by 1500 hours, KST on the closing date of RFP.

iii) SUBMISSION REQUIREMENTS

a) PRICING PROPOSAL: The pricing proposal must clearly indicate prices for each Contract Line Item Number in Section B - Supplies or Services and Prices.

b) DETAILED OFFER BREAKDOWN: The detailed offer breakdown must clearly identify all costs that can materially impact the statement of work.

c) SECTION K - Representations, Certifications and Other Statements of Offerors SECTION K-TAXES: Offerors must complete all tax portions of SECTION K. The offeror shall review all expenses to ensure that all applicable taxes are excluded from the overall price. In addition, offerors shall propose exemptions of specific ROK taxes that are legitimate, attributable to the contract, and authorized by the applicable stated references.

SECTION K-OTHER: Offerors must complete all Non-Tax related portions of SECTION K.

iv) COMPLIANCE WITH SOLICITATION: Failure to submit the above requirements under SECTION L may be grounds for determining the proposal to be non-compliant. For example, if a detailed offer breakdown is not submitted, the contracting officer will be unable to find the offeror's pricing proposal acceptable and the offeror's proposal will be ineligible for award. Non-compliance will only be cured if the government holds discussions as detailed in SECTION L.

52.236-27 SITE VISIT (CONSTRUCTION) (FEB 1995) – ALTERNATE I (FEB 1995)

(a) The clauses at 52.236-2, Differing Site Conditions, and 52.236-3, Site Investigations and Conditions Affecting the Work, will be included in any contract awarded as a result of this solicitation. Accordingly, offerors or quoters are urged and expected to inspect the site where the work will be performed.

(b) An organized site visit has been scheduled for--

Date and Time : 14 Sep 18, 0900 hours POC : So, Ki Chong, DSN: 730-3713, Cell: 010-2718-7476

Location : Building No. 2409, Room #424, Camp Casey

End of provision)

5152.236-4011 CONSTRUCTION PRICE RANGE

Pursuant to FAR 36.204 the estimated price range is between $ 1,000,000 and $5,000,000.

Section M - Evaluation Factors for Award

BASIS OF AWARD

Electronic offers submitted by 1500 hours, KST on the closing date of RFP shall be considered timely.

i) EVALUATION CRITERIA The pricing proposal shall be evaluated to determine whether it is complete and reasonable. A complete and reasonable pricing proposal will be deemed acceptable.

The detailed offer breakdown will be used by the contracting officer to determine whether proposed prices are complete and reasonable. A detailed offer breakdown may be used by the contracting officer to determine whether an offeror is able to complete the requirements under the contract, and/or whether discussions will be conducted pursuant to instructions to the offerors.

ii) SECTION K - Representations, Certifications and Other Statements of Offerors

a. SECTION K-TAXES will be evaluated to determine whether it is complete. In addition, propose exemptions of specific ROK taxes will be evaluated to determine whether they are legitimate, attributable to the contract, authorized, and reasonable. A complete SECTION-K that only proposes exemptions of specific ROK taxes that are legitimate, attributable to the contract, necessary to complete the Task Order, do not improperly overstate any proposed tax exemption, authorized, and reasonable will be deemed acceptable.

b. SECTION K-OTHER will be evaluated to determine whether it is complete. A complete SECTION K-OTHER will be deemed acceptable.

BASIS FOR AWARD: Award shall be made to the responsible offeror submitting the lowest priced offer that is evaluated as acceptable for all evaluation criteria.