Drawing_files___109375___Bldg294___CIVIL.PDF

PDF 290 KB Posted

Attached to
Repair bunkers, CRC
Solicitation number
W91QVN-18-R-0048
Issued by

About this file

bldg. 294 civil

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TANK CELL B

STAIR

INDUSTRIAL WATER INDUSTRIAL WATER

TANK CELL C

INDUSTRIAL WATER

TANK CELL D

INDUSTRIAL WATER

TANK CELL A

DOMESTIC WATER

TANK CELL A

DOMESTIC WATER

TANK CELL B

PUMP ROOM

ROOM

CORR

60451016 610 6045 610

CIVIL

AS SHOWN

CHOE, S M.

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

FORCE PROTECTION

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

1:100

0 10M7.552.5

SCALE: 1 / 100

DOMESTIC WATER

TANK CELL BTANK CELL A

DOMESTIC WATER

60451016 610 6045 610

ROOM

PUMP

LOWER LEVEL FLOOR PLAN

SCALE: 1 / 100

KEY PLAN

SCALE: NONE

SCOPE OF WORK

SCHEDULE #1 (REPAIR/MAINTENANCE)

2 LOWER LEVEL SECTION

LINING SHEET

4MM THK PE

LINING SHEET

4MM THK PE

CAMP RED CLOUD

109375

C-1

LOWER LEVEL FLOOR PLAN,

SECTION AND SCOPE OF WORK

AFTER CLEANING THE TANKS.

CEILING) OF CONCRETE DOMESTIC WATER STORAGE TANKS

PE LINING SHEET ON INNER SURFACE(WALL, BOTTOM SLAB,

1. REPLACE DETERIORATED EPOXY COATING W/ 4MM THK

REPAIR BUNKERS, BLDG S-294, S-50 & S-55

(BLDG S-294)

(t=4mm)

CON'C

PE SHEET

PE SHEET

ANCHOR ��

PE SHEET

PDF ��

PE WELDING

ANGLE

WELDING

WELDING

/L

/L

/L

L

��/STS-PIPE

PE ��

TEST HOLE

STS-BAND

PE SHEET

150*150

PE ��

(STS304,M6*60)

CIVIL

AS SHOWN

CHOE, S M.

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

FORCE PROTECTION

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

CAMP RED CLOUD

PE �� ��

PE �� Bar

PE�� ���

SCALE: NONE

DETAILS

DETAILS

C-2

1 2 3

REPAIR BUNKERS, BLDG S-294, S-50 & S-55

(BLDG S-294)

109375

109375-1
109375-2
109375-3
109375-4