- Membrane Roof Replacement and Masonry Repairs, Pump Station at Fox Point Hurricane Barrier, Providence, RI
- Solicitation number
- W912WJ25QA010
About this file
The attached document contains revised attachments for a U.S. Army Corps of Engineers solicitation (W912WJ25QA010) for roof replacement and masonry repairs at the Fox Point Hurricane Barrier Pump Station in Providence, Rhode Island. The project involves replacing the existing Ethylene Propylene Diene Monomer (EPDM) roof system with a new fully adhered 90 mil nominal thickness EPDM roofing system, including complete demolition of the existing roof down to the 5-inch concrete roof slab.
Key technical requirements include demolishing and removing 5 courses of exterior brick wall, removing the original through-wall metal flashing, and installing new 16 oz copper through-wall flashing 7 inches higher than the original. The new roof system must be designed for high wind coastal conditions and carry a 30-year warranty. The procurement is set aside for small businesses under NAICS code 238160 with a $19 million size standard, with an estimated construction value between $100,000 and $250,000. All vendors must have an active SAM.gov registration to be considered responsive.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment W912WJ25QA010-0003.pdf | ||
| Amendment W912WJ25QA010-0002.pdf | ||
| Amendment W912WJ25QA010-0001.pdf | ||
| Attachments 25QA010.pdf | ||
| Solicitation W912WJ25QA010.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIGURE 1 - General location of the pumpstation building.
FIGURE 2 - Layout of work area at the pumpstation
REVISED ATTACHMENTS - AMENDMENT 0002
FIGURE 3 - Demolition Plan
FIGURE 4 - Demolition Section
FIGURE 5 - As built Conditions of Existing Roof
FIGURE 6 - As built Conditions of Existing Roof
FIGURE 7 - As built Conditions of Existing Roof
FIGURE 8 – New work required
FIGURE 9 – New work required
FIGURE 10 – Details of flashing in the brick wall
FIGURE 11 – Details of expansion joint
FIGURE 12– Details of new wall flashing
FIGURE 13 – Existing Conditions
FIGURE 14 – Existing Conditions
Informational Photo 1 - Looking west.
Informational Photo 2 – Looking east.
Informational Photo 3 – Looking west.
Informational Photo 4 – Looking east.
Additional Informational Photo #5
Additional Information Photo #6
Additional Information Photo #7