The attached document contains revised attachments for a U.S. Army Corps of Engineers solicitation (W912WJ25QA010) for roof replacement and masonry repairs at the Fox Point Hurricane Barrier Pump Station in Providence, Rhode Island. The project involves replacing the existing Ethylene Propylene Diene Monomer (EPDM) roof system with a new fully adhered 90 mil nominal thickness EPDM roofing system, including complete demolition of the existing roof down to the 5-inch concrete roof slab.

Key technical requirements include demolishing and removing 5 courses of exterior brick wall, removing the original through-wall metal flashing, and installing new 16 oz copper through-wall flashing 7 inches higher than the original. The new roof system must be designed for high wind coastal conditions and carry a 30-year warranty. The procurement is set aside for small businesses under NAICS code 238160 with a $19 million size standard, with an estimated construction value between $100,000 and $250,000. All vendors must have an active SAM.gov registration to be considered responsive.

View the file

Other files

File Type Posted
Amendment W912WJ25QA010-0003.pdf PDF
Amendment W912WJ25QA010-0002.pdf PDF
Amendment W912WJ25QA010-0001.pdf PDF
Attachments 25QA010.pdf PDF
Solicitation W912WJ25QA010.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIGURE 1 - General location of the pumpstation building.

FIGURE 2 - Layout of work area at the pumpstation

REVISED ATTACHMENTS - AMENDMENT 0002

FIGURE 3 - Demolition Plan

FIGURE 4 - Demolition Section

FIGURE 5 - As built Conditions of Existing Roof

FIGURE 6 - As built Conditions of Existing Roof

FIGURE 7 - As built Conditions of Existing Roof

FIGURE 8 – New work required

FIGURE 9 – New work required

FIGURE 10 – Details of flashing in the brick wall

FIGURE 11 – Details of expansion joint

FIGURE 12– Details of new wall flashing

FIGURE 13 – Existing Conditions

FIGURE 14 – Existing Conditions

Informational Photo 1 - Looking west.

Informational Photo 2 – Looking east.

Informational Photo 3 – Looking west.

Informational Photo 4 – Looking east.

Additional Informational Photo #5

Additional Information Photo #6

Additional Information Photo #7

Attachments 25QA010.pdf
Additional Photo 2.pdf
Additional Photo 1.pdf
Additional Photo 3.pdf

File details come from the government source that posted it. Updated .