- Membrane Roof Replacement and Masonry Repairs, Pump Station at Fox Point Hurricane Barrier, Providence, RI
- Solicitation number
- W912WJ25QA010
About this file
This document is a Solicitation Notice (W912WJ25QA010) issued by the U.S. Army Corps of Engineers - New England District for a membrane roof replacement and masonry repair project at the Fox Point Hurricane Barrier Pump Station in Providence, Rhode Island. The project is set aside for small businesses with a NAICS code of 238160 and a small business size standard of $19 million, with an estimated construction value between $100,000 and $250,000.
The specific scope of work includes replacing the existing Ethylene Propylene Diene Monomer (EPDM) roof system with a new fully adhered 90 mil nominal thickness EPDM roofing system. This involves complete demolition of the current roof down to the concrete slab, removing at least 5 rows of brick in the adjacent wall to install a new through-wall metal flashing 7 inches higher than the original. The new roofing system must be designed for high wind coastal conditions and carry a 30-year warranty. Vendors must have an active SAM.gov registration to be considered, and those without will be rejected as non-responsive.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment W912WJ25QA010-0003.pdf | ||
| Attachments 25QA010_Revised.pdf | ||
| Amendment W912WJ25QA010-0002.pdf | ||
| Amendment W912WJ25QA010-0001.pdf | ||
| Solicitation W912WJ25QA010.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIGURE 1 - General location of the pumpstation building.
FIGURE 2 - Layout of work area at the pumpstation
FIGURE 3 - Demolition Plan
FIGURE 4 - Demolition Section
FIGURE 5 - As built Conditions of Existing Roof
FIGURE 6 - As built Conditions of Existing Roof
FIGURE 7 - As built Conditions of Existing Roof
FIGURE 8 – New work required
FIGURE 9 – New work required
FIGURE 10 – Details of flashing in the brick wall
FIGURE 11 – Details of expansion joint
FIGURE 12– Details of new wall flashing
FIGURE 13 – Existing Conditions
FIGURE 14 – Existing Conditions
Informational Photo 1 - Looking west.
Informational Photo 2 – Looking east.
Informational Photo 3 – Looking west.
Informational Photo 4 – Looking east.