J-3 AHERA Asbestos Information_Osan MHS - Summary Asbestos Containing Materials.pdf
PDF 70 KB Posted
- Attached to
- DoDEA Total Maintenance Services Federal contract opportunity
- Solicitation number
- W912UM19R0021
About this file
This document provides a summary of asbestos-containing materials found in several buildings on an Air Force base. The summary identifies the material, location, quantity, condition, potential for damage, recommended management actions, and cost estimates for ongoing surveillance or future abatement. Notable findings include assumed asbestos-containing fire door linings and roofing materials that were not sampled due to inaccessibility or potential damage during sampling. The recommended actions emphasize ongoing surveillance and compliance with custodial procedures rather than immediate abatement.
The related federal contract opportunity is a solicitation from the Department of Defense Education Activity seeking comprehensive maintenance services for eight schools and a district office. The contractor will provide preventative maintenance, inspections, and on-demand repairs up to a demand maintenance threshold. Emergency response is required within one hour. The contract term is one base year with four one-year options and covers services such as carpentry, plumbing, electrical work, and roofing. The location of services will include facilities in the DoDEA school system.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| J-4 System Inventory Report.pdf | ||
| J 3 AHERA Asbestos Information_Humphreys Central ES_No Asbestos Containing Material.pdf | ||
| J-8 DoDEA Point Paper for RPIE vs Non-RPIE.docx | DOCX document | |
| J-5 QASP DoDEA TMC.docx | DOCX document | |
| J-3 AHERA Asbestos Information_Osan ES.pdf | ||
| J-2 Site and Facility Drawings_Humphreys.pdf | ||
| J 3 AHERA Asbestos Information_Humphreys High School - No Asbestos Containing Material.pdf | ||
| J-2 Site and Facility Drawings_Osan ES.pdf | ||
| J-7 Work Order History_Hupmpreys .xlsx | XLSX spreadsheet | |
| J-3 AHERA Asbestos Information_Daegu AS Asbestos Containing Material.pdf | ||
| RFP DoDEA TMC.pdf | ||
| J-1 Facility Summaries and Standards_Facility Condition Assess Report_All Schools.pdf | ||
| J-6 Pacific-West_TMC- Deliverables.pdf | ||
| J-7 Work Order History_Daegu.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Quantities are approximate and not intended for abatement bidding purposes. 1 2018
Bldg.
No.
Homo.
Mtl.
No.
Material Description
AHERA
CAT Locations Quantity Friable Overall
Condition Type of Damage Accessibility Potential for
Air Erosion Potential for
Vibration Potential for
Damage EPA Ass.
CAT
Cleaning Required
Recommended Management Actions
Begin Date
End Date
Material Management Procedure Unit Cost Est. Qty.
(Unit) Est. Cost Comments
Number Date Result
Building: 472
472 124
FIRE DOOR
LINING, CORE
OF ELEVATOR
ENTRANCE
DOORS MISC. A103, C202 2 EA ASSUMED ACM 14-Jun-12 - NO UNDAMAGED NONE LOW LOW LOW
LOW
POTENTIAL 8 NO
1. NO IMMEDIATE ABATEMENT
REQUIRED.
2. CONSULT THE O&M MANUAL
CONCERNING SAFE CUSTODIAL
PROCEDURES FOR THIS
MATERIAL.
3. CONTINUE SURVEILLANCE
OF THIS MATERIAL UNDER THE
ASBESTOS MANAGEMENT PLAN. REMOVABLE ITEMS $72.50 1.5 $108.75
THIS MATERIAL WAS NOT
SAMPLED DUE TO
INACCESSIBILITY AND IS
THEREFORE ASSUMED TO
CONTAIN ASBESTOS. THIS
MATERIAL WAS NOT
ACCESSIBLE FOR
ADEQUATE INSPECTION
BECAUSE MATERIAL IS
LOCATED INSIDE METAL
DOOR.
Building: 492
492 013
ROOFING
SYSTEM, BLACK,
SINGLE-PLY
FLEXIBLE
MEMBRANE,
LABELED
CARLISLE. MISC. ROOF 5,000 SF ASSUMED ACM 29-Aug-09 - NO UNDAMAGED NONE MEDIUM LOW LOW POTENTIAL 5 NO
1. NO IMMEDIATE ABATEMENT
REQUIRED.
2. CONSULT THE O&M MANUAL
CONCERNING SAFE CUSTODIAL
PROCEDURES FOR THIS
MATERIAL.
3. CONTINUE SURVEILLANCE
OF THIS MATERIAL UNDER THE
ASBESTOS MANAGEMENT PLAN.
EXTERIOR
WEATHERPROOFING
MATERIALS $72.50 18 $1,305.00
THIS MATERIAL WAS NOT
SAMPLED DUE TO
POTENTIAL DAMAGE TO THE
ROOF. ALL OF THE
COMPONENTS OF THIS
ROOFING SYSTEM SHOULD
BE SAMPLED PRIOR TO
RENOVATION OR REMOVAL
OF ANY PART OF THIS
ROOF.
492 018
FIRE DOOR
LINING, CORE
OF ELEVATOR
ENTRANCE
DOOR MISC. C10 , C201 2 EA ASSUMED ACM 15-Jun-12 - NO UNDAMAGED NONE LOW LOW LOW
LOW
POTENTIAL 8 NO
1. NO IMMEDIATE ABATEMENT
REQUIRED.
2. CONSULT THE O&M MANUAL
CONCERNING SAFE CUSTODIAL
PROCEDURES FOR THIS
MATERIAL.
3. CONTINUE SURVEILLANCE
OF THIS MATERIAL UNDER THE
ASBESTOS MANAGEMENT PLAN. REMOVABLE ITEMS $72.50 1.5 $108.75
THIS MATERIAL WAS NOT
SAMPLED DUE TO
INACCESSIBILITY AND IS
THEREFORE ASSUMED TO
CONTAIN ASBESTOS. THIS
MATERIAL WAS NOT
ACCESSIBLE FOR
ADEQUATE INSPECTION
BECAUSE MATERIAL IS
LOCATED INSIDE METAL
DOOR. GLOBAL ELEVATOR
MANUFACTURING CO. 1-1/2
HOUR RATED LABELED
DOOR.
Building: 494
494 121
FIRE DOOR
LINING, CORE
OF ELEVATOR
ENTRANCE
DOORS MISC. 307, 408 2 EA ASSUMED ACM 14-Jun-12 - NO UNDAMAGED NONE LOW LOW LOW
LOW
POTENTIAL 8 NO
1. NO IMMEDIATE ABATEMENT
REQUIRED.
2. CONSULT THE O&M MANUAL
CONCERNING SAFE CUSTODIAL
PROCEDURES FOR THIS
MATERIAL.
3. CONTINUE SURVEILLANCE
OF THIS MATERIAL UNDER THE
ASBESTOS MANAGEMENT PLAN. REMOVABLE ITEMS $72.50 1.5 $108.75
THIS MATERIAL WAS NOT
SAMPLED DUE TO
INACCESSIBILITY AND IS
THEREFORE ASSUMED TO
CONTAIN ASBESTOS. THIS
MATERIAL WAS NOT
ACCESSIBLE FOR
ADEQUATE INSPECTION
BECAUSE MATERIAL IS
LOCATED INSIDE METAL
DOOR. GLOBAL ELEVATOR
MANUFACTURING CO. 1-1/2
HOUR RATED LABELED
DOOR.
Table D-1 - Summary of Asbestos-Containing Materials for Osan MS/HS
Sample Information
File details come from the government source that posted it. Updated .