J-3 AHERA Asbestos Information_Daegu AS Asbestos Containing Material.pdf
PDF 68 KB Posted
- Attached to
- DoDEA Total Maintenance Services Federal contract opportunity
- Solicitation number
- W912UM19R0021
About this file
This document outlines requirements for a firm fixed price maintenance services contract. The Department of Defense Education Activity seeks a contractor to provide comprehensive preventative maintenance, inspections, and on-demand repair services for eight schools and a district office in the DoDEA school system. Services include carpentry, masonry, painting, plumbing, electrical work, HVAC, fire protection, metal work and roofing. The contractor must provide emergency response within one hour for all locations. The base period of performance is one year with four optional one-year extensions. The solicitation was released by the U.S. Army Corps of Engineers Far East District on behalf of the DoDEA.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| J-7 Work Order History_Daegu.pdf | ||
| J 3 AHERA Asbestos Information_Humphreys High School - No Asbestos Containing Material.pdf | ||
| J-4 System Inventory Report.pdf | ||
| J-3 AHERA Asbestos Information_Osan MHS - Summary Asbestos Containing Materials.pdf | ||
| J 3 AHERA Asbestos Information_Humphreys Central ES_No Asbestos Containing Material.pdf | ||
| J-8 DoDEA Point Paper for RPIE vs Non-RPIE.docx | DOCX document | |
| J-5 QASP DoDEA TMC.docx | DOCX document | |
| J-3 AHERA Asbestos Information_Osan ES.pdf | ||
| J-2 Site and Facility Drawings_Humphreys.pdf | ||
| J-2 Site and Facility Drawings_Osan ES.pdf | ||
| J-7 Work Order History_Hupmpreys .xlsx | XLSX spreadsheet | |
| RFP DoDEA TMC.pdf | ||
| J-1 Facility Summaries and Standards_Facility Condition Assess Report_All Schools.pdf | ||
| J-6 Pacific-West_TMC- Deliverables.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Quantities are approximate and not intended for abatement bidding purposes. 1 2018
Bldg.
No.
Homo.
Mtl.
No.
Material Description
AHERA
CAT Locations Quantity Friable Overall
Condition Type of Damage Accessibility Potential for
Air Erosion Potential for
Vibration Potential for
Damage EPA Ass.
CAT
Cleaning Required
Recommended Management Actions
Begin Date
End Date
Material Management Procedure Unit Cost Est. Qty.
(Unit) Est. Cost Comments
Number Date Result
Building: 3000
3000 026
RESILIENT
FLOOR
SHEETING,
BROWN,
YELLOW, GOLD,
AND TAN
PEBBLE DESIGN
WITH WHITE
PAPER BACKING MISC.
A117, A117A, A210, A224, A226, A227, A228 1,500 SF
1101-TAE-001
1101-TAE-001*
01-Nov-90 01-Nov-90
CH 10%
CH 11-13% NO UNDAMAGED NONE LOW LOW LOW
LOW
POTENTIAL 8 NO
1. NO IMMEDIATE ABATEMENT
REQUIRED.
2. CONSULT THE O&M MANUAL
CONCERNING SAFE CUSTODIAL
PROCEDURES FOR THIS
MATERIAL.
3. CONTINUE SURVEILLANCE
OF THIS MATERIAL UNDER THE
ASBESTOS MANAGEMENT PLAN.
RESILIENT FLOOR
TILE OR SHEETING $72.50 15 $1,087.50
*SAMPLE WAS ANALYZED
BY TEM AND RESULT WAS
>1% ASBESTOS. THIS
MATERIAL IS CONSIDERED
TO BE ACM. THIS
MATERIAL IS LOCATED
UNDER EXISTING
FLOORING MATERIALS AND
CABINETS IN LISTED
LOCATIONS. THE
ADHESIVE FOR THIS
MATERIAL IS MN 027.
3000 056
SHEET GASKET,
PINK, 4" - 6"
DIAMETER, ON
PIPE FLANGE
CONNECTIONS MISC. M101, M106 22 EA
0715-TAE-056A
0715-TAE-056B
0715-TAE-056C
15-Jul-93 15-Jul-93 15-Jul-93
CH 60-65%
CH 60-65%
CH 60-65% NO UNDAMAGED NONE MEDIUM LOW LOW POTENTIAL 5 NO
1. NO IMMEDIATE ABATEMENT
REQUIRED.
2. CONSULT THE O&M MANUAL
CONCERNING SAFE CUSTODIAL
PROCEDURES FOR THIS
MATERIAL.
3. CONTINUE SURVEILLANCE
OF THIS MATERIAL UNDER THE
ASBESTOS MANAGEMENT PLAN.
GASKET MATERIAL
AND FLEX
CONNECTORS $72.50 1.5 $108.75
THIS MATERIAL WAS NOT
ACCESSIBLE FOR
ADEQUATE INSPECTION
BECAUSE IT IS UNDER
SEALED BLACK FOAM
INSULATION.
3000 117
SHEET GASKET,
GRAY, ON 4" -
6" DIAMETER,
ON PIPE FLANGE
CONNECTIONS MISC. M101 16 EA
0597-TAE-117A
0597-TAE-117B
0597-TAE-117C
02-May-97 02-May-97 02-May-97
CH 20-25%
CH 60-65%
CH 60-65% NO UNDAMAGED NONE MEDIUM LOW LOW POTENTIAL 5 NO
1. NO IMMEDIATE ABATEMENT
REQUIRED.
2. CONSULT THE O&M MANUAL
CONCERNING SAFE CUSTODIAL
PROCEDURES FOR THIS
MATERIAL.
3. CONTINUE SURVEILLANCE
OF THIS MATERIAL UNDER THE
ASBESTOS MANAGEMENT PLAN.
GASKET MATERIAL
AND FLEX
CONNECTORS $72.50 1.5 $108.75
THIS MATERIAL WAS NOT
ACCESSIBLE FOR
ADEQUATE INSPECTION
BECAUSE IT IS UNDER
SEALED BLACK FOAM
INSULATION.
3000 235
FIRE DOOR
LINING, CORE
OF ELEVATOR
ENTRANCE
DOORS MISC. H103, H201 2 EA ASSUMED ACM 05-Jun-12 - NO UNDAMAGED NONE LOW LOW LOW
LOW
POTENTIAL 8 NO
1. NO IMMEDIATE ABATEMENT
REQUIRED.
2. CONSULT THE O&M MANUAL
CONCERNING SAFE CUSTODIAL
PROCEDURES FOR THIS
MATERIAL.
3. CONTINUE SURVEILLANCE
OF THIS MATERIAL UNDER THE
ASBESTOS MANAGEMENT PLAN. REMOVABLE ITEMS $72.50 1.5 $108.75
THIS MATERIAL WAS NOT
SAMPLED DUE TO
INACCESSIBILITY AND IS
THEREFORE ASSUMED TO
CONTAIN ASBESTOS. THIS
MATERIAL WAS NOT
ACCESSIBLE FOR
ADEQUATE INSPECTION
BECAUSE MATERIAL IS
LOCATED INSIDE METAL
DOOR.
3000 239
FIRE DOOR
LINING, CORE
OF ELEVATOR
CAB DOOR MISC. EL101.1 1 EA ASSUMED ACM 05-Jun-12 - NO UNDAMAGED NONE LOW LOW LOW
LOW
POTENTIAL 8 NO
1. NO IMMEDIATE ABATEMENT
REQUIRED.
2. CONSULT THE O&M MANUAL
CONCERNING SAFE CUSTODIAL
PROCEDURES FOR THIS
MATERIAL.
3. CONTINUE SURVEILLANCE
OF THIS MATERIAL UNDER THE
ASBESTOS MANAGEMENT PLAN. REMOVABLE ITEMS $72.50 1.5 $108.75
THIS MATERIAL WAS NOT
SAMPLED DUE TO
INACCESSIBILITY AND IS
THEREFORE ASSUMED TO
CONTAIN ASBESTOS. THIS
MATERIAL WAS NOT
ACCESSIBLE FOR
ADEQUATE INSPECTION
BECAUSE MATERIAL IS
LOCATED INSIDE METAL
DOOR.
Building: 3008
3008 177
ROOFING
SYSTEM,
BROWN
ASPHALTIC
SHINGLES MISC. ROOF 1,200 SF ASSUMED ACM 19-Oct-06 - NO UNDAMAGED NONE MEDIUM LOW LOW POTENTIAL 5 NO
1. NO IMMEDIATE ABATEMENT
REQUIRED.
2. CONSULT THE O&M MANUAL
CONCERNING SAFE CUSTODIAL
PROCEDURES FOR THIS
MATERIAL.
3. CONTINUE SURVEILLANCE
OF THIS MATERIAL UNDER THE
ASBESTOS MANAGEMENT PLAN.
EXTERIOR
WEATHERPROOFING
MATERIALS $72.50 6 $435.00
THIS MATERIAL WAS NOT
SAMPLED DUE TO
POTENTIAL DAMAGE TO THE
ROOF. ALL OF THE
COMPONENTS OF THIS
ROOFING SYSTEM SHOULD
BE SAMPLED PRIOR TO
RENOVATION OR REMOVAL
OF ANY PART OF THIS
ROOF.
Building: 3019
3019 201
SHEET GASKET,
4" - 6"
DIAMETER,
WHITE,
PAINTED RED
ON FIRE
SUPPRESSION
WATER PIPING MISC. M101 11 EA
KR09-TAE-201A
KR09-TAE-201B
KR09-TAE-201C
18-Aug-09 18-Aug-09 18-Aug-09
CH 10%
CH 10%
CH 10% NO UNDAMAGED NONE MEDIUM LOW LOW POTENTIAL 5 NO
1. NO IMMEDIATE ABATEMENT
REQUIRED.
2. CONSULT THE O&M MANUAL
CONCERNING SAFE CUSTODIAL
PROCEDURES FOR THIS
MATERIAL.
3. CONTINUE SURVEILLANCE
OF THIS MATERIAL UNDER THE
ASBESTOS MANAGEMENT PLAN.
GASKET MATERIAL
AND FLEX
CONNECTORS $72.50 1.5 $108.75
Table D-1 - Summary of Asbestos-Containing Materials for Daegu American School