W912QR26BA001_Plans-0002.pdf

PDF 16 MB Posted

Attached to
Repair of the Squadron Operations Facility, Building 7087, at Westover Air Reserve Base
Solicitation number
W912QR26BA001
Issued by

About this file

These are architectural and engineering drawing files for the renovation of the Squadron Operations Facility (Building 7087) at Westover Air Reserve Base in Massachusetts. The comprehensive set of technical drawings covers multiple disciplines including architectural demolition plans, interior finishes, furniture and equipment layouts, electrical systems, mechanical systems, telecommunications infrastructure, and civil engineering details for a 37,000 square foot facility renovation.

The drawings detail a phased renovation approach across Level 1 and Level 2 of the facility, with specific focus on Areas C, D, G, and H. Key elements include comprehensive demolition of existing systems, replacement of electrical and HVAC infrastructure, installation of new telecommunications networks, interior finish upgrades, and integration of new furniture and equipment. The project involves complex renovations that must maintain operational continuity for existing systems like the C-5 simulator and base communications infrastructure. The technical drawings are part of a construction contract with an estimated duration of 519 calendar days, with a total project value anticipated between $10 million and $25 million, issued by the US Army Corps of Engineers Louisville District.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAWING ABBREVIATIONS

REVISION

DRAWING SYMBOLS

SHEET ON WHICH DETAIL

IS DRAWN

BUILDING ELEVATION

WALL SECTION

BUILDING SECTION

ROOM NAME AND

NUMBER

NOTES BY SYMBOL

(KEYNOTES)

A2

A-201

A1

A-310

A1

A-301

A1

A-301

A0

A-101

A-201

A4

A4

A4

A4

INTERIOR ELEVATION

MULTIPLE VIEWS

DETAIL IDENTIFICATION

TITLE OF DRAWING

STATED SCALE

TRUE NORTH ARROW

TRUE NORTH

DETAIL IDENTIFICATION

ENLARGED PLAN/DETAIL

REFERENCE

A1

A-101

A1

A2

A3

SCALE 1/8" = 1'-0"

VIEW NAME

A1

ROOM

NAME

NUMBERING SYSTEM

G-010

DISCIPLINE:

G - GENERAL

V - SURVEY/MAPPING

B - GEOTECHNICAL

C - CIVIL

L - LANDSCAPE

S - STRUCTURAL

A - ARCHITECTURE

I - INTERIORS

F - FIRE PROTECTION

P - PLUMBING

D - PROCESS

M - MECHANICAL

E - ELECTRICAL

T - TELECOMM

R - RESOURCES

SERIES NUMBER

0 - GENERAL

1 - PLANS

2 - ELEVATIONS

3 - SECTIONS

4 - ENLARGED PLANS

5 - DETAILS

6 - SCHEDULES

7 - DIAGRAMS

8 - USER DEFINED

9 - 3D REPRESENTATIONS

SHEET NUMBER

WITHIN SERIES

A

GRID TYPE

MATCHLINE

A1/AE101

VIEW REFERENCE /

MATCHLINE

NOTES BY SYMBOL

(DEMO-KEYNOTES)

02 4 8134

SCALE: 1/4"=1'-0"

GRAPHIC SCALE

X

X

R E

G I S

T

ERED ARCH

IT

E

C T

S T

A T E

O F T EX

A S

M A T

TH

EW THOMAS

H A

R E

2 2 8 5 3

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J A

C O

B S

G O

V E

R N

M E

N T

S E

R V

IC

E

S C

O

T e xa s R e g is te re d E n g in e e ri n g F ir m

F -2

M a in

S tr e e t, F o rt

W o rt h

T X

F

IL

E N

A M

E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

R E

P A

IR

S

Q U

A D

R O

N O

P E

R A

T

IO

N S

B L D

G

H A

N G

A R

W E

S T

O V

E R

A R

B M

A U

S A

C E

P

A F

P R

O J E

C T

Y

T P

M

-0

CERTIFIED FINAL

V S

A R

O N

I

G

IN

G L

IS

M H

A R

E

M H

A R

E

J a c o b s P ro j.

N o

L

D A

R

D

E C

GI003

A B

B R

E V

IA

T

IO

N

S A

N D

D R

A W

IN

G

S Y

M B

O L

S

Y T

P M

-0

-G

I0

A

A AMPERE

A LABEL CLASS A DOOR

A/C AIR CONDITIONING

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT/ ENGINEER

AASHTO AMERICAN ASSOCIATION OF STATE HIGHWAY

AND TRANSPORTATION OFFICIALS

AB ANCHOR BOLT

ABAAG ARCHITECTURAL BARRIERS ACT ACCESSIBILITY

GUIDELINES

AC ALTERNATING CURRENT/ABOVE COUNTER,

ASPHALT CONCRETE

ACC ACCESSIBLE

ACI AMERICAN CONCRETE INSTITUTE

ACS AUTOMATIC CONTROL SYSTEM

ACS DR ACCESS DOOR

ACS FLR ACCESS FLOOR

ACS PNL ACCESS PANEL

ACST ACOUSTICAL

ACT ACOUSTICAL CEILING TILE

AD AIR DEVICE

ADA AMERICANS WITH DISABILITIES ACT

ADDL ADDITIONAL

ADJ ADJUSTABLE

ADMIN ADMINISTRATION

AF AMPERE FRAME

AFC ABOVE FINISHED COUNTER

AFCI ARC FAULT CIRCUIT INTERRUPTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFS ABOVE FINISHED SLAB

AGGR AGGREGATE

AHU AIR HANDLING UNIT

AIB AIR INFILTRATION BARRIER

AIC AMPERE INTERRUPTING CAPACITY

AISC AMERICAN INSTITUTE OF STEEL

CONSTRUCTION

ALNMT ALIGNMENT

ALUM ALUMINUM

ANOD ANODIZE

ANT ANTENNA

APC ACOUSTICAL PANEL CEILING

APPROX APPROXIMATE (-LY)

ARCH ARCHITECT (-TURAL)

ASC ABOVE SUSPENDED CEILING

ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS

ASPH ASPHALT

ASSY ASSEMBLY

ASTM AMERICAN SOCIETY FOR TESTING AND

MATERIALS

ASYM ASYMMETRICAL

AT AMPERE TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AVG AVERAGE

AWG AMERICAN WIRE GAUGE

AWI ARCHITECTURAL WOODWORK INSTITUTE

AWT ACOUSTICAL WALL TREATMENT

AWWA AMERICAN WATER WORKS ASSOCIATION

B

B LABEL CLASS B DOOR

B-B, B/B BACK TO BACK

BALC BALCONY

BATT BATTERY

BB BASEBOARD

BBW BACK BOTTOM OF WALL

BC BACK OF CURB, BOTTOM OF CURB, BOOKCASE

BD BOARD

BDRY BOUNDARY

BEG BEGIN

BEV BEVEL

BF BOTH FACES

BFF BELOW FINISH FLOOR

BFP BACKFLOW PREVENTER

BHMA BUILDER'S HARDWARE MANUFACTURER'S

ASSOCIATION

BKBD BACKBOARD

BLDG BUILDING

BLKG BLOCKING

BLT IN BUILT-IN

BLW BELOW

BM BALANCED MAGNETIC SWITCH, BEAM,

BENCHMARK

BMPS BEST MANAGEMENT PRACTICES

BMS BUILDING MANAGEMENT SYSTEM

BN BULLNOSE

BOD BOTTOM OF DUCT

BOP BOTTOM OF PIPE

BOS BOTTOM OF STEEL

BOT BOTTOM

BP BASE PLATE, BUILDING PAPER

BRES BULLET-RESISTANT

BRG BEARING

BRKR BREAKER

C

C CHANNEL, CHANNEL SHAPE, COMPRESSION,

CONDUIT

C CONT CAST CONCRETE

C LABEL CLASS C DOOR

C&G CURB AND GUTTER

C-C, C/C, C

TO C

CENTER TO CENTER

CAB CABINET

CATW CATWALK

CAV CAVITY

CB CATCH BASIN, CERAMIC BASE, CIRCUIT

BREAKER

CBB CEMENTITIOUS (BACKER) BOARD

CCH CORROSION CONTROL HANGAR

CD CARBON DIOXIDE SENSOR

CDW CHILLED DRINKING WATER

CEM CEMENT

CEM PLAS CEMENT PLASTER

CEQ COLLATERAL EQUIPMENT

CER CERAMIC

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/ CONTRACTOR

INSTALLED

CF/GI CONTRACTOR FURNISHED/ GOVERNMENT

INSTALLED

CFE CONTRACTOR FURNISHED EQUIPMENT

CFLG COUNTER FLASHING

CFM CUBIC FEET PER MINUTE

CFMF COLD-FORMED METAL FRAMING

CFS CUBIC FEET PER SECOND

CG CORNER GUARD

CHFR CHAMFER

CI CAST IRON, CURB INLET

CIP CAST IRON PIPE, CAST-IN-PLACE

CJ CONSTRUCTION JOINT, CONTROL JOINT

CKT CIRCUIT

CL CENTER LINE, CLASS

CLDG CLADDING

CLG CEILING

CLG DIFF CEILING DIFFUSER

CLG HT CEILING HEIGHT

CLL COLUMN LINE

CLO CLOSET

CLR CLEAR, (-ANCE), COLOR

CLRM CLASSROOM

CLWG CLEAR WIRE GLASS

CM CENTIMETER

CMPST COMPOSITE

CMU CONCRETE MASONRY UNIT

CNDS CONDENSATE

CNR CORNER

CO CLEAN OUT

CO/ NOX CARBON MONOXIDE / NITROGEN OXIDE

COE CORPS OF ENGINEER'S (US ARMY)

COL COLUMN

COMM COMMUNICATION (-S)

COMPR COMPRESSOR

CONC CONCRETE

CONC FLR CONCRETE FLOOR

CONF CONFERENCE

CONN CONNECT (-ION)

CONST CONSTRUCT (-ION)

CONT CONTINUED, CONTINUOUS

COORD COORDINATE

COR CONTRACTING OFFICER'S REPRESENTATIVE

CORR CORRIDOR

COV COVER

CP CIRCULATION PUMP, CONCRETE PIPE

CPT CARPET

CR CONTROL ROOM

CRS COLD ROLLED STEEL

CS CAST STONE

CSWK CASEWORK

CT CERAMIC TILE, CURRENT TRANSFORMER

CTB CEMENT TREATED BASE, CERAMIC TILE BASE

CTF CERAMIC TILE FLOOR

CTR CENTER

CTRL CONTROL

CU CONDENSING UNIT, COPPER

CU FT CUBIC FEET

CW CASEMENT WINDOW

CWR CONDENSER WATER RETURN

CWS CONDENSER WATER SUPPLY

D

D DEPTH

D LABEL CLASS D DOOR

E

E EAST (FOR COORDINATES)

E LABEL CLASS E DOOR

EA EACH, EXHAUST AIR

EDP1 EMERGENCY DISTRIBUTION PANELBOARD 1

EEWS EMERGENCY EYEWASH/SHOWER

EF EACH FACE

EF, EXH FN EXHAUST FAN

EGB ELECTRICAL GROUND BAR

EHD ELECTRIC HAND DRYER

EIFS EXTERIOR INSULATION AND FINISH SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRIC (-AL)

ELEV ELEVATOR

EMCS ENERGY MANAGEMENT CONTROL SYSTEM

EMER EMERGENCY

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

ENGR ENGINEER

ENTR ENTRANCE

ENVIR ENVIRONMENT

EOD EDGE OF DECK

EOS EDGE OF SLAB

EP EDGE OF PAVEMENT, EXPLOSION PROOF

EPS EXPANDED POLYSTYRENE BOARD (INSULATION)

EQ EQUAL

EQUIP EQUIPMENT

ES EACH SIDE, HVAC EMERGNECY SWITCH

ESB EMERGENCY SWITCHBOARD

ESCAL ESCALATOR

ESD ELECTROSTATIC DISSIPATING

ET EXPANSION TANK

EW EACH WAY

EWC ELECTRIC WATER COOLER

EWEF EACH WAY, EACH FACE

EX, EXIST EXISTING

EXH EXHAUST

EXH HD EXHAUST HOOD

EXHV EXHAUST VENT

EXP EXPANSION, EXPOSED

EXT EXTERIOR, EXTINGUISHER

EXT GR EXTERIOR GRADE

EXT LT EXIT LIGHT

F

F FEMALE, FIRE WATER

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACIL FACILITY

FACP FIRE ALARM CONTROL PANEL

FAS BD FASCIA BOARD

FB FACE OF BUILDING

FC FREQUENCY CONVERTER/FOOTCANDLE

FC BRK FACE BRICK

FC/ DC FREQUENCY CONVERTER/DC RECTIFIER

FCO FLOOR CLEANOUT

FCU FAN COIL UNIT

FD FIRE DAMPER, FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

G

G GROUND/GROUNDING CONDUCTOR, NATURAL

GAS

GA GAGE OR GAUGE

GAL GALLON

GALV GALVANIZED

GB GRAB BAR, GRADE BEAM

GDR GUARDRAIL

GEN GENERAL, GENERATOR

GF/CI GOVERNMENT FURNISHED / CONTRACTOR

INSTALLED

GF/GI GOVERNMENT FURNISHED / GOVERNMENT

INSTALLED

GFCI, GFI GROUND FAULT CIRCUIT INTERRUPTER

GFE GOVERNMENT FURNISHED EQUIPMENT

GFRG GLASS-FIBER-REINFORCED GYPSUM

REINFORCED GYPSUM

GLZ GLAZING

GND/GRD GROUND/GROUNDING

GPM GALLONS PER MINUTE

GR GRADE

GR FL GROUND FLOOR

GRTG GRATING

GSB GYPSUM SHEATHING BOARD

GT GROUT

GUT GUTTER

GV GATE VALVE

GYP BD GYPSUM BOARD

GYP PLAS GYPSUM PLASTER

B

BRKT BRACKET

BRZ BRONZE

BS BOTH SIDES

BSMT BASEMENT

BTU BRITISH THERMAL UNIT

BTWN BETWEEN

BUR BUILT-UP ROOFING

D

D/S DISCONNECT SWITCH

DA DRAINAGE AREA

DALI DIGITAL ADDRESSABLE LIGHTING INTERFACE

DB DIRECT BURIAL, DRY BULB

DBL DOUBLE

DBM DOUBLE BALANCED MAGNETIC SWITCH

DC DIRECT CURRENT

DCBFP DOUBLE CHECK BACKFLOW PREVENTER

DCD DOUBLE CHECK DETECTOR

DCO DOUBLE CLEANOUT

DCW DOMESTIC COLD WATER

DEF DEFLECTION/DEFORM

DEG DEGREE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DHW DOMESTIC HOT WATER

DI DUCTILE IRON

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DIR DIRECTION

DISC DISCONNECT

DIST DISTANCE

DL DEAD LOAD

DN DOWN

DOC DOCUMENT

DR DOOR, DRIVE

DR FR DOOR FRAME

DR OPN DOOR OPENING

DS DOWNSPOUT

DW DISHWASHER, DOMESTIC WATER

DWG(S) DRAWING(S)

DWL DOWEL

DX DIRECT EXPANSION

F

FDN, FDT FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FED FEDERAL

FF FINISH FACE, FINISH FLOOR

FF EL FINISH FLOOR ELEVATION

FF INSUL FOIL FACED INSULATION

FF&E FURNITURE, FIXTURES & EQUIPMENT

FG FINISHED GRADE

FGL FIBERGLASS

FH FIRE HOSE

FHP FULL HEIGHT PARTITION

FIN FINISH

FIN BS FINISH BOTH SIDE

FIN GR FINISH GRADE

FIXT FIXTURE

FL FLOW LINE

FLA FULL LOAD AMPERES

FLDG FOLDING

FLEX FLEXIBLE

FLG FLOORING

FLMT FLUSH MOUNT

FLOUR FLOURESCENT

FLR FLOOR

FM FACTORY MUTUAL, FORCE MAIN, FREQUENCY

MODULATION

FO FAIL OPEN, FIBER OPTIC, FINISH OPENING

FOC FACE OF CONCRETE

FOM FACE OF MASONRY

FOW FACE OF WALL

FP FIRE PROTECTION

FPM FEET PER MINUTE

FR FIRE RATING, FIRE RESISTANT

FRG FIBER REINFORCED GYPSUM

FRP FIBERGLASS REINFORCED PLASTIC

FRTW FIRE RETARDANT TREATED WOOD

FS FAR SIDE, FEDERAL SPECIFICATION, FINISHED

SURFACE, FLOOR SINK

FSTNR FASTENER

FT FEET

FTG FOOTING

FU FUSE

FURG FURRING

FURN FURNITURE

FVNR FULL VOLTAGE, NON-REVERSING

FWC FABRIC WALL COVERING

FXTR FIXTURE

H

HP HIGH POINT, HORSEPOWER

HR HOUR

HS HEADED STUD

HSF HIGH FLOW SILT FENCE

HSS HOLLOW STRUCTURAL SECTION

HT, H HEIGHT

HVAC HEATING VENTILATION & AIR CONDITIONING

HW HOT WATER

HYDR HYDRAULIC

HZ HERTZ

H

HB HOSE BIBB

HC HANDICAP

HDPE HIGH DENSITY POLYETHYLENE

HDW HARDWARE

HDWD HARDWOOD

HDWL HEADWALL

HEF HIGH EXPANSION FOAM

HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)

HH HANDHOLE

HID HIGH INTENSITY DISCHARGE

HM HOLLOW METAL

HMAC HOT MIX ASPHALT CONCRETE

HMD HOLLOW METAL DOOR

HMF HOLLOW METAL FRAME

HNDRL HANDRAIL

HOA HAND-OFF-AUTOMATIC

HORIZ HORIZONTAL

I

IAP INITIAL ACCUMULATION POINT

IBC INTERNATIONAL BUILDING CODE

ID INTERNAL DIAMETER

IDA INITIAL DECONTAMINATION AREA

IDS INTRUSION DETECTION SYSTEM

IN INCH

INCL INCLUDE

INL INLET

INT INTERIOR

INV INVERT

J

J-SIIDS JOINT-SERVICE INTERIOR INTRUSION

DETECTION SYSTEM

JAN JANITOR

JB JUNCTION BOX

JRCP JOINT REINFORCED CONCRETE PAVEMENT

JST JOIST

JT JOINT

K

K KILO, KIPS (1000LBS)

KAIC KILO AMPERE INTERRUPTING CAPACITY

KCMIL THOUSAND CIRCULAR MILS

KIT KITCHEN

KPD KEYPAD

KPL KICKPLATE

KV KILOVOLT

KVA KILOVOLT-AMPERE

KW KILOWATT

KWh KILOWATT HOUR

L

L ANGLE SHAPE, LENGTH, LONG

LAM LAMINATE

LAT LATERAL

LAV LAVATORY

LB, LBS POUND

LBP LEAD BASED PAINT

LBR LUMBER

LCP LEAD CONTAINING PAINT, LIGHTING CONTROL

PANEL

LDG LANDING

LE/FE LOW EMITTING AND FUEL EFFICIENT

LED LIGHT EMITTING DIODE

LF LINEAR FEET (LONG)

LFMC LIQUID-TIGHT FLEXIBLE METAL CONDUIT

LG LONG

LH LEFT HAND

LIB LIBRARY

LIN LINEAR

LKR LOCKER

LL LIVE LOAD

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LNDSCP LANDSCAPE

LOC LOCATION

LP LOW POINT

LS LIME-STABILIZED, LUMP SUM

LSIG LONG TIME, SHORT TIME, INSTANTANEOUS,

GROUND FAULT

LT LEFT, LIGHT

LTG LIGHTING

LV LOW VOLTAGE

LVDR LOUVER DOOR

LVR LOUVER

LYR LAYER

1 1

A

M E

N D

M E

N T

B

ID

D E

R I N

Q U

IR

IE

S

N

O V

11/21/2025

W

2Q R

BA

1_

Pl an s-

R E

G I S

T

ERED ARCH

IT

E

C T

S T

A T E

O F T EX

A S

M A T

TH

EW THOMAS

H A

R E

2 2 8 5 3

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J A

C O

B S

G O

V E

R N

M E

N T

S E

R V

IC

E

S C

O

T e xa s R e g is te re d E n g in e e ri n g F ir m

F -2

M a in

S tr e e t, F o rt

W o rt h

T X

F

IL

E N

A M

E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

R E

P A

IR

S

Q U

A D

R O

N O

P E

R A

T

IO

N S

B L D

G

H A

N G

A R

W E

S T

O V

E R

A R

B M

A U

S A

C E

P

A F

P R

O J E

C T

Y

T P

M

-0

CERTIFIED FINAL

V S

A R

O N

I

G

IN

G L

IS

M H

A R

E

M H

A R

E

J a c o b s P ro j.

N o

L

D A

R

D

E C

A-001

G E

N E

R A

L N

O T

E S

A N

D G

E N

E R

A L

D E

M O

L

IT

IO

N

P L A

N N

O T

E S

Y T

P M

-0

-A

-0

GENERAL DEMOLITION PLAN NOTES

1 DEMOLITION NOTES ARE TO DEFINE INTENT. DEMOLITION MUST INCLUDE ALL ITEMS INDICATED ON THE DEMOLITION PLANS AND ALL

OTHER ITEMS REQUIRED TO BE DEMOLISHED TO ACCOMPLISH NEW CONSTRUCTION AND FINISH INDICATED THROUGHOUT SET OF

CONTRACT DOCUMENTS

2 ALL DEMOLITION WORK MUST BE PERFORMED WITH "DUE CARE AND DILIGENCE" IN ORDER TO PREVENT ARBITRARY DAMAGE OR INTERRUPTION OF SERVICE OF CONCEALED UTILITIES INTENDED TO REMAIN IN SERVICE. DISCOVERY OF CONDITIONS LOCATED DIFFERENTLY FROM THAT INDICATED OR NOT IDENTIFIED, SHALL BE REPORTED TO THE CONTRACTING OFFICER PRIOR TO

DEMOLITION

3 THE INFORMATION ON THESE DEMOLITION SHEETS IS DIAGRAMMATIC AND IS NOT INTENDED TO SHOW EACH AND EVERY CONDITION

OF THE EXISTING BUILDING

4 EXISTING CONSTRUCTION SHOWN BASED UPON CONTRACTING OFFICER FURNISHED PLANS AND ONSITE OBSERVATIONS. ANY DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL FIELD CONDITIONS MUST BE REPORTED TO THE CONTRACTING OFFICER PRIOR

TO PROCEEDING WITH WORK.

5 THE DEMOLITION IN HANGAR 1 WILL NOT BE COMPLETED ALL AT ONCE; IT WILL BE PHASED IN THREE (3) SEPERATE DEMOLITION AND

CONSTRUCTION PHASES. PHASES 3 AND 4 APPLY TO THE WEST AND SOUTH WINGS ONLY.

6 THE SCOPE OF DEMOLITION (WHERE APPLICABLE): REMOVE ALL EXISTING FLOOR FINISHES, WALL BASES, FURR-OUTS, PARTITIONS AND PORTIONS OF MASONRY WALLS (AS INDICATED IN PLANS), WAINSCOTS, CEILING SYSTEMS, UTILITY SUPPORTS AND OTHER MISCELLANEOUS, CONSTRUCTION UNLESS OTHERWISE NOTED TO PROVIDE A CLEAN SPACE TO INITIATE NEW CONSTRUCTION IN

THE AREAS DESIGNATED FOR NEW WORK.

7 FIELD VERIFY EXISTING CONDITIONS AND INFORM THE CONTRACTING OFFICER OF ANY DISCREPANCIES BETWEEN DRAWINGS AND

ACTUAL FIELD CONDITIONS PRIOR TO PROCEEDING WITH WORK.

8 COORDINATE WITH THE CONTRACTING OFFICER THE SCHEDULE OF WORK AND SAFETY DEMARCATIONS

9 COORDINATE WITH CONTRACTING OFFICER FOR DEMOLITION / STAGING SCHEDULE BEFORE DEMOLITION BEGINS

10 CONTRACTOR IS TO PROTECT AND MAINTAIN EXISTING ROOF, PLUMBING, ELEC, LIGHTING, AND FIRE PROTECTION THAT IS REQUIRED TO REMAIN IN SERVICE; REFER TO MECHANICAL, PLUMBING, ELECTRICAL, AND FIRE PROTECTION.

11 PROVIDE TEMPORARY AIR TIGHT DUST PARTITIONS TO SEPARATE AREAS OF DEMOLITION AND CONSTRUCTION FROM OCCUPIED AREAS; COORDINATE WITH FINISH WORK AND PHASING SCHEDULE. REFER TO SHEET A-600 FOR THE TEMPORARY DUST PARTITION

TYPE.

12 COORDINATE ALL DEMOLITION WORK WITH CONTRACTING OFFICER, AS PORTIONS OF FACILITY WILL CONTUNUE TO BE IN

OPERATION DURING THE LENGTH OF THE PROJECT.

13 THE CONTRACTOR IS TO STOP WORK IMMEDIATELY AND NOTIFY THE CONTRACTING OFFICER IF ASBESTOS CONTAINING MATERIALS

ARE DISCOVERED THAT ARE NOT SHOWN ON THE HAZMAT SHEETS H-001 THRU H-005.

14 VERIFY THAT AREAS REQUIRED TO REMAIN IN USE ARE SEPARATED PROPERLY FROM THOSE WHERE DEMOLITION WILL BE CONDUCTED, DUST CONTROLS ARE IN PLACE, FIRE SAFETY AND EXIT ROUTES ARE READIED FOR CONTINUOUS USE (PROPER

SIGNAGE, ILLUMINATION AND FIRE EXTINGUISHERS ARE IN PLACE), ETC.

15 REFER TO CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR DEMOLITION OF ADDITIONAL ITEMS, TYPICAL FOR ALL AREAS.

16 IN THE AREAS DESIGNATED FOR NEW WORK ALL HOLES CREATED IN THE EXISTING ROOF, FROM THE REMOVAL OF EXISTING VENT PIPES, EXHAUST FANS, AND OTHER ITEMS, WILL BE PATCHED PER SMACNA AND TPO ROOFING GUIDELINES LISTED IN SPECIFICATION

SECTION 07 54 23 TO MAINTAIN EXISTING ROOF WARRANTY.

17 IN THE AREAS DESIGNATED FOR NEW WORK REMOVE ALL HARDWARE, HANGERS, ANCHOR SYSTEMS, MISC METAL ATTACHMENTS, ETC. PATCH AND FINISH TO MATCH ADJACENT SURFACE.

18 REFER TO STRUCTURAL FOR INSTALLATION OF NEW LINTELS, IN MASONRY WALL AREAS DESIGNATED TO BE OPENED. (DOORS, PASSAGE WAYS, DUCTWORK, ETC.)

19 REMOVE ALL ABANDONED CEILING SYSTEMS AND THEIR SUPPORTS. PROVIDE A CLEAN SPACE TO INITIATE NEW CONSTRUCTION.

20 COORDINATE WITH STRUCTURAL FOR AREAS OF EXISTING CONCRETE FLOOR AND ROOF THAT NEED TO BE OPENED FOR NEW

UTILITY INSTALLATIONS.

21 REFER TO STRUCTURAL, FIRE PROTECTION, PLUMBING, MECHANICAL, AND ELECTRICAL DRAWINGS FOR LOCATIONS OF ADDITIONAL

PENETRATIONS.

22 REPAIR AND FINISH ALL HOLES IN WALLS, UNDERSIDE OF CONCRETE DECKS AND FLOORS LEFT FROM REMOVAL OF HARDWARE, FASTENERS, DUCTS, PIPES, CONDUIT, ETC AND RESTORE TO ORIGINAL INTEGRITY; RE: STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL

23 ALL MATERIALS REMOVED BY CONTRACTOR MUST BE DISPOSED OF BY CONTRACTOR AT AN OFF-SITE LOCATION, UNLESS

OTHERWISE NOTED BY CONTRACTING OFFICER.

24 REFER TO STRUCTURAL FOR SPECIFIC AREAS OF STRUCTURAL DEMOLITION.

25 PATCH AND REPAIR ALL HOLES IN WALLS, CEILINGS, CONCRETE COLUMNS, AND FLOORS PRODUCED DURING DEMOLITION. PATCH

TO MATCH ADJACENT CONSTRUCTION.

26 A HAZARDOUS MATERIALS SURVEY HAS BEEN CONDUCTED FOR HANGAR 1. SEE SPECIFICATIONS SECTION: 01 57 19.00 06 FOR THE INSPECTION REPORT. REPORT ANY SUSPICIOUS MATERIAL SUCH AS UNIDENTIFIED WASTE, IMPROPERLY STORED FUELS OR CHEMICALS, ETC NOT IDENTIFIED IN THE INSPECTION REPORT TO THE CONTRACTING OFFICER AND REQUEST GUIDANCE.

27 ONLY THE SINGLE-STORY, WEST WING ROOF OF THE HANGAR ROOF HAS BEEN INSPECTED FOR HAZARDOUS MATERIALS. THE CONTRACTOR MUST PERFORM TESTS AS NEEDED FOR HAZARDOUS MATERIALS PRIOR TO DISTURBING ROOF MATERIALS. THE CONTRACTOR IS RESPONSIBLE FOR PROPER HANDLING AND DISPOSAL OF ANY HAZARDOUS MATERIALS ENCOUNTERED.

28 CONTRACTOR IS TO PROTECT EXISTING CONCRETE ENCASED CRITICAL TIE RODS IN-LINE WITH THE STEEL ARCHES +/-9" UNDER

FLOOR SLAB OF THE CENTRAL BAY, NORTH WING, AND SOUTH WING.

29 AT SAW CUTS OF EXISTING CONCRETE FLOOR SLAB; COORDINATE WITH CONTRACTING OFFICER FOR SCHEDULING OF CUTTING OF FLOOR SLAB. CONTRACTOR TO OVERSEE CONCRETE FLOOR CUTTING PROCESS AND CONTROL / MITIGATE FLYING DUST. USE VACUUM CLEANER DURING CUTTING EXERCISE. NEW INFILL TO ALIGN WITH EXISTING ADJACENT FACE OF SLAB.

30 THE CONTRACTOR IS RESPONSIBLE FOR IMPLEMENTING ALL INSTRUCTIONS AND GUIDELINES IN THE HAZMAT REPORT AS FOUND IN SPECIFICATIONS FOR ALL ACTIVITIES ASSOCIATED WITH DEMOLITION AND REMEDIATION FOR ALL CONSTRUCTION ACTIVITIES

DURING THE BUILDING RENOVATION.

31 CONTRACTOR TO EXERCISE CARE DURING DEMOLITION OF AREAS LIKELY TO CONTAIN HIDDEN OR OBSCURED SYSTEMS BEYOND

FINISHED SURFACES.

32 THE CONTRACTOR MUST VERIFY CONSTRUCTION LAYOUT PRIOR TO COMMENCEMENT OF CONSTRUCTION.

33 CONTRACTOR SHOULD FIELD MEASURE ALL EXISTING OPENINGS WHERE DOORS AND WINDOWS WILL BE INSTALLED.

34 COORDINATE ALL NEW MEP OPENINGS REQUIRED IN THE HORIZONTAL ASSEMBLIES WITH OTHER DISCIPLINES.

35 REFER TO DEMOLITION ELEVATIONS ON SHEETS AD200 AND AD201 FOR REMOVAL OF EXISTING WINDOWS, DOORS, AND LOUVERS.

36 ALL EXISTING STEEL LINTELS ABOVE DOORS, WINDOWS, LOUVERS, AND OPENINGS SHALL BE CLEANED OF ALL VISIBLE RUST AND

OLD FINISHES, AND THEN PRIMED AND PAINTED.

37 IN FILL HOLES IN EXISTING SLAB AND FINISH AT LOCATIONS OF REMOVED PLUMBING DRAINS, VENTS, PIPES, ETC. PATCH TO MATCH

ADJACENT SURFACE

38 SHOULD CONSTRUCTION WORK REQUIRE WORK TO BE PERFORMED OUTSIDE THE PHASE 3 AND 4 LIMITS, REFER TO THE HAZARDOUS MATERIALS REPORT IN THE SPECIFICATIONS SECTION 01 57 19.00 06 FOR POTENTIAL ASBESTOS CONTAINING

MATERIALS (ACM) PRIOR TO BEGINNING THE WORK.

39 SHOULD CONSTRUCTION WORK REQUIRE WORK TO BE PERFORMED OUTSIDE THE PHASE 3 AND 4 LIMITS, REPAIR THE AREAS DISTURBED OR DAMAGED BY WORK DONE IN THAT AREA TO MATCH THE EXISTING FINISHES AND CONSTRUCTION.

40 ALL PAINTED SURFACES ARE ASSUMED TO CONTAIN LEAD AND WILL BE MANAGED IN ACCORDANCE WITH THE OSHA LEAD IN CONSTRUCTION STANDARD 29 CFR 1926.62. SEE SPECIFICATIONS SECTION: 01 57 19.00 06 FOR THE INSPECTION REPORT.

41 THE EXISTING C-5 TRAINING SIMULATOR ENCLOSURE IN THE CENTRAL BAY IS TO REMAIN IN PLACE AND MUST REMAIN IN OPERATION DURING CONSTRUCTION. PROTECT C-5 SIMULATOR AND ALL UTILITIES THAT SERVICE IT DURING CONSTRUCTION. ANY DISRUPTIONS IN UTILITY SERVICES TO THE C-5 SIMULATOR AND HANGAR 1 MUST BE COORDINATED WITH THE CONTRACTING OFFICER A MINIMUM

OF 15 CALENDAR DAYS IN ADVANCE.

GENERAL NOTES

1 HANGAR 1 IS AN ACTIVE BUILDING AND WILL CONTINUE TO BE USED WHILE THE RENOVATION WORK IS BEING DONE

2 COORDINATE WITH CONTRACTING OFFICER TO IDENTIFY SECURE AND/OR "OFF-LIMITS" AREAS IN THE HANGAR WHILE THE BUILDING

IS BEING RENOVATED.

3 REFER TO A-600 FOR PARTITION TYPES AND DETAILS.

4 DO NOT SCALE DRAWINGS FOR CONSTRUCTION PURPOSES.

5 BUILDING RENOVATION DRAWINGS INDICATE THE GENERAL INTENT OF DEMOLITION FOR THE PURPOSE OF CONSTRUCTING NEW SYSTEMS AND ASSEMBLIES. CARE HAS BEEN EXERCISED TO IDENTIFY THE EXISTING SERVICES (PLUMBING LINES, ELECTRICAL LINES, AND TELECOM LINES) AND EXISTING CONSTRUCTION DETAILS WHERE NEW CONSTRUCTION TAKES PLACE. EXISTING SERVICES TO REMAIN MUST STAY IN PLACE. HOWEVER, NOT ALL EXISTING CONDITIONS MAY BE INDICATED; YET THE CONTRACTOR IS NONE THE LESS RESPONSIBLE FOR CONSTRUCTING A COMPLETED PROJECT REGARDLESS OF ENCOUNTERED UNDOCUMENTED ASSEMBLIES AND SERVICES. ANY UNDOCUMENTED SERVICES AND ASSEMBLIES ENCOUNTERED DURING CONSTRUCTION SHALL BE IDENTIFIED TO THE CONTRACTING OFFICER AND DOCUMENTED. PRIOR TO REQUESTING ADDITIONAL INFORMATION, THE CONTRACTOR SHALL REVIEW ALL SIMILAR CONDITIONS AND PROPOSE AN ALTERNATIVE SOLUTION BASED ON A SIMILAR CONTRACT

DOCUMENT DETAIL

6 THERE IS NO EXISTING VAPOR BARRIER UNDER THE EXISTING LEVEL 1 SLAB. A FLUID APPLIED MOISTURE MITIGATING SEALER MUST BE APPLIED BEFORE INSTALLING NEW FLOOR FINISHES AND ADHESIVES ON THE EXISTING LEVEL 1 SLAB. CONTRACTOR MUST INSURE THAT THE MOISTURE MITIGATING SEALER IS COMPATIBLE WITH THE NEW FLOOR FINISHES AND ADHESIVES AND DOES NOT

VOID THE MANUFACTURER'S WARRANTY OF THE FLOOR FINISHES AND ADHESIVES.

7 REPAIR ANY HOLES IN EXISTING WALLS CAUSED BY PHASE 3 AND 4 CONSTRUCTION

8 VERIFY AND DOCUMENT CONDITIONS AND DIMENSIONS ON THE JOB.

9 VERIFY SIZE, LOCATIONS AND CHARACTERISTICS OF ALL EQUIPMENT TO BE FURNISHED WITH MANUFACTURERS OR SUPPLIERS

BEFORE BEGINNING CONSTRUCTION

10 VERIFY SIZE AND LOCATION OF ALL OPENINGS FOR EQUIPMENT AND RELATED WORK

11 ALL PLAN DIMENSIONS ARE TO FACE OF GYPSUM BOARD, FACE OF CONCRETE MASONRY UNITS OR CENTERLINE OF COLUMNS.

12 REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL LOCATIONS OF PENETRATIONS OCCURRING

WITHIN FLOOR, WALL, CEILING AND ROOF SYSTEMS.

13 REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR LOCATIONS OF EQUIPMENT NOT SHOWN ON ARCHITECTURAL

DRAWINGS.

14 COORDINATE LOCATIONS OF ALL NEW AND EXISTING FLOOR DRAINS, REFER TO PLUMBING.

15 THE LEAN TO'S FINISH FLOOR ELEVATION OF 0'-9" IS A RELATIVE ELEVATION USED FOR DESIGN COORDINATION WITHIN THE FACILITY. REFER TO CIVIL ENGINEERING DRAWING FOR ACTUAL TOPOGRAPHICAL ELEVATIONS.

16 THE PARTIAL DEMOLITION ASSOCIATED WITH PHASE 3 AND 4 WILL BASICALLY BE CONCENTRATED IN THE WEST WING AND THE FIRST AND SECOND FLOOR OF THE SOUTH WING. ADDITIONAL TEMPORARY DEMOLITION AND RENOVATION WORK WILL BE LOCATED IN THE INTERIOR MECHANICAL AREA IN THE CENTRAL BAY. REFER TO MEP FOR PARTIAL DEMOLITION OF EXISTING MEP

REQUIREMENTS AND TIMING REGARDING SYSTEMS.

17 AT THE INITIATION OF DEMOLITION WORK, COORDINATE WITH THE CONTRACTING OFFICER ON THE FOLLOWING: ACCESS TO THE HANGAR, ACCESS TO DESIGNATED PORTIONS OF THE HANGAR, ACCESS TO THE FLIGHT-LINE (THE BASE REQUIRES SPECIFIC ACTIONS AND METHODOLOGIES OF PROTECTION DUE TO SAFETY AND SECURITY IN THE FLIGHT-LINE AND

PROTECTION/SEPARATION REQUIREMENTS FOR PERSONNEL)

18 DURING THE DEMOLITION PROCESS, COORDINATE WITH THE CONTRACTING OFFICER ON THE FOLLOWING: SALVAGING OF SPECIFIC ITEMS, WORK SCHEDULES, AND AREAS THAT NEED TO BE SEPARATED BECAUSE OTHER PORTIONS OF THE HANGAR WILL REMAIN IN

USE.

19 COORDINATE WITH CONTRACTING OFFICER FOR DEMOLITION OF EXISTING SYSTEMS LOCATED BEYOND THE PERIMETER OF THE BUILDING (RE: CIVIL) AND PROTECTION/SEPARATION OF ADJACENT AREAS TO REMAIN IN USE.

20 VERIFY THAT AREAS REQUIRED TO REMAIN IN USE ARE SEPARATED PROPERLY FROM THOSE WHERE DEMOLITION WILL BE CONDUCTED, DUST CONTROLS ARE IN PLACE, FIRE SAFETY AND EXIT ROUTES ARE READIED FOR CONTINUOUS USE (PROPER

SIGNAGE, ILLUMINATION AND FIRE EXTINGUISHERS ARE IN PLACE), ETC.

21 COORDINATE WITH CONTRACTING OFFICER WHICH EXTERIOR DOOR IS GOING TO BE USED AT EACH PHASE OF DEMOLITION AND CONSTRUCTION AND INSTALL PROPER SEPARATION OF CIRCULATION AT EXTERIOR SPACES TO PREVENT THE MIX OF PERSONNEL

(MILITARY AND CONSTRUCTION)

22 FOR ADDITIONAL GENERAL AND DEMOLITION NOTES REFER THIS SHEET, FLOOR PLANS, AND ELEVATIONS.

23 REFER TO SHEET GI009 FOR AIR BARRIER BOUNDARIES FOR THE PHASE III AND IV SCOPE OF WORK.

A

M E

N D

M E

N T

B

ID

D E

R I N

Q U

IR

IE

S

N

O V

11/21/2025

W

2Q R

BA

1_

Pl an s-

A B C

2.8

3.8

4.8

5.8

MATCHLINE

REFER A6 AD111

AD201

B5

AD200

D5

056056

054025

025 054

056056

056 027

025 003

033033033

025054

054014

UCC/

FLYING

SUPER

OPS

OFFICER

SECRETARY

1110OPS

OFFICER

WOMEN'S

MEN'S

MECH

FOYER

LOBBY

MECH

GEN

STOR

CLASSIFIED

WORKSTATIONS

INTEL

WORK

AREA

TACTICS

OFFICE

1114.1

TACTICS

TESTING

HALL

MECH

UCC/

FLYING

SUPER

1109.1

CLASSIFIED

TRNG

SIMULATOR

ROOM

AIRCREW

BRIEFING

RM

106052

049 106

014 054

014 029029

054014025

052052

TYP

3'-0"

108108

042042

AD201

A5

061 061

052052

9'-0"

054014

T Y

P

027027

033033

BOILER

STORAGE

1119.1 033

014 054

A B C

8.2

9.2

10.2

10.8

11.8

MATCHLINE

REFER A2 AD111

M A

T C

H L

IN

E

R E

F E

R D

A

D

ELECTRICAL

025 014

AIRCREW

BRIEFING

RM

AFE

EQUIP

STORAGE

1125.2

COMPUTER

WORK

STATIONS

AFE

WORK

1125.1

AFE

SUPER

BREAK

RM

AFE

WORK

STATION

AFE

EQUIP

STORAGE

AFE

CLASSRM

054054

073073

108108

014 054

025054

014 054

025014 054

161161

AREA OF EXIST MASONRY WALL TO

BE REMOVED; REFER TO STRUCT

FOR NEW LINTELS

APPROX LOCATION AND SIZE OF

CONC FLOOR SLAB TO BE REMOVED

FOR NEW WORK. RE: MEP AND

STRUCT FOR BACK-FILL. BACK-FILL

TO ALIGN WITH EXIST FACE OF SLAB.

EXISTING PARTITION TO BE REMOVED

REMOVE EXISTING DOOR AND

DOOR FRAME SYSTEM, UNO

LEGEND

EXISTING PARTITION TO REMAIN

R E

G I S

T

ERED ARCH

IT

E

C T

S T

A T E

O F T EX

A S

M A T

TH

EW THOMAS

H A

R E

2 2 8 5 3

164 8268

SCALE: 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J A

C O

B S

G O

V E

R N

M E

N T

S E

R V

IC

E

S C

O

T e xa s R e g is te re d E n g in e e ri n g F ir m

F -2

M a in

S tr e e t, F o rt

W o rt h

T X

F

IL

E N

A M

E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

R E

P A

IR

S

Q U

A D

R O

N O

P E

R A

T

IO

N S

B L D

G

H A

N G

A R

W E

S T

O V

E R

A R

B M

A U

S A

C E

P

A F

P R

O J E

C T

Y

T P

M

-0

CERTIFIED FINAL

C

D

AREAS C&D

KEY PLANKEY PLAN

V S

A R

O N

I

G

IN

G L

IS

M H

A R

E

M H

A R

E

J a c o b s P ro j.

N o

L

D A

R

D

E C

AD111

P A

R T

IA

L

D E

M O

L

IT

IO

N

P L A

N S

L E

V E

L

A

R E

A S

C A

N D

D

Y T

P M

-0

-A

D

SCALE 1/8" = 1'-0"A2

PARTIAL DEMOLITION PLAN - LEVEL 1 - AREA C

SCALE 1/8" = 1'-0"A6

PARTIAL DEMOLITION PLAN - LEVEL 1 - AREA D

GENERAL NOTES - DEMO PLANS

A REFER TO GI003 FOR ABBREVIATIONS.

B REFER TO A-001 FOR GENERAL NOTES, GENERAL DEMOLITION PLAN

NOTES, AND SYMBOLS.

C REFER TO AD140 EXISTING ROOM FINISH SCHEDULE.

D FF&E REMAINING AFTER GOVERNMENT PERSONNEL MOVE OUT WILL BE

REMOVED FROM BUILDING AND DISPOSED OF BY THE GENERAL

CONTRACTOR.

E REMOVE FURRING PARTITION AT EXTERIOR WALLS. EXTERIOR MASONRY

WALL TO REMAIN. CLEAN AND PREP FOR APPLICATION OF FLUID APPLIED

AIR BARRIER. TYPICAL AT ALL EXTERIOR WALLS.

KEYNOTES

001 REMOVE SIGNAGE AND ATTACHMENTS; INFILL ANY HOLES TO MATCH

EXTERIOR FINISHES AS REQUIRED. RETURN OR DISPOSE OF SIGNAGE AS

INSTRUCTED BY CONTRACTING OFFICER.

003 REMOVE DOOR AND FRAME SYSTEM. INFILL WALL, REFER TO PLANS.

006 CONTRACTOR TO REMOVE AWNING AND SALVAGE FOR REINSTALLATION

ONCE THE ENTRY STOREFRONT HAS BEEN REPLACED AND MASONRY

REPAIRS HAVE BEEN MADE AT THIS LOCATION. REFER TO PLANS AND

EXTERIOR ELEVATIONS.

007 REMOVE BRICK MASONRY PANEL FROM MASONRY OPENING; PROTECT

REMAINING PERIMETER MASONRY AND SILL.

009 REMOVE FURRED WALL UNDER BASE HEATERS.

011 REMOVE PORTION OF WALL FOR NEW DOOR, REFER TO FLOOR PLAN

014 REMOVE ALL FLOOR FINISHES AND BASE TRIM IN THIS AREA.

022 SALVAGE OVERHEAD PROJECTOR AND RETURN TO CONTRACTING

OFFICER.

025 REMOVE CEILING, LIGHTING, DIFFUSERS, AND ASSOCIATED CEILING

MOUNTED EQUIPMENT IN THIS AREA. REFER TO MECHANICAL AND

ELECTRICAL

026 REMOVE WALK-OFF MAT.

027 REMOVE CASEWORK AND COUNTERS.

028 REMOVE 6" TALL RAISED PLATFORM AND RAMP.

029 SALVAGE DISPLAY CASE AND OR MARKER BOARD; RETURN TO

CONTRACTING OFFICER.

030 SALVAGE WALL-MOUNTED FLAT TELEVISION AND RETURN TO

CONTRACTING OFFICER.

033 REMOVE HVAC UNIT, DUCTWORK, AND ASSOCIATED SUPPORTS AND

WIRING; REFER TO MEP FOR ADDITIONAL DEMOLITION NOTES.

038 REMOVE STEEL ENTRY CANOPY AND SUPPORTING STRUCTURE. PATCH

AND REPAIR EXTERIOR MASONRY WALL AS NEEDED WITH BRICK TO

MATCH EXISTING.

042 REMOVE PORTION OF WALL TO ALLOW FOR ACCESS TO INSTALL

PREFINISHED ALUMINUM WINDOWS, REFER TO PLANS. TYPICAL

044 HVAC EQUIPMENT TO REMAIN. PROTECT DURING CONSTRUCTION; REFER

TO MEP.

049 STEEL COLUMNS TO REMAIN. CLEAN OFF ANY LOOSE PAINT AND PREPARE

FOR NEW FINISHES, REFER TO PLANS.

050 REMOVE AND DISPOSE OF AUDITORIUM SEATING AND ASSOCIATED

HARDWARE.

052 SALVAGE PROJECTION SCREEN SYSTEM AND RETURN TO CONTRACTING

OFFICER.

054 REMOVE VINYL WALLCOVERING FROM WALLS AND PREPARE WALL FOR

PAINT, TYPICAL

056 REMOVE WINDOW AND/OR DOOR SYSTEM AND INTERIOR WINDOW SILL.

EXTERIOR WINDOW SILL TO REMAIN; PROTECT.

057 REMOVE AND DISPOSE DEMOUNTABLE PARTITIONS

058 REMOVE FLOOR MOUNTED ACCESS GRATE AND PREPARE OPENING FOR

NEW FLOOR MOUNTED ACCESS HATCH, REFER TO FLOOR PLAN

061 REMOVE DISPOSE OF ACCORDION PARTITION, TRACK, GYPSUM BOARD

CEILING AND SUPPORT STRUCTURE ABOVE.

062 FIRE PROTECTION EQUIPMENT TO REMAIN. PROTECT DURING

CONSTRUCTION, REFER TO FIRE PROTECTION.

065 ROOF DRAIN SYSTEM AND LEADERS TO REMAIN, REFER TO PLUMBING.

073 REMOVE PLUMBING FIXTURES, REFER TO PLUMBING

077 EXISTING EXHAUST CHASE TO REMAIN, PROTECT DURING

CONSTRUCTION.

078 REMOVE FIRE EXTINGUISHER CABINET; PATCH AND REPAIR WALL

097 REMOVE BASE HEATERS, TYPICAL, RE: MECHANICAL

098 TEMPORARY DUST PARTITION AND DOOR; REFER TO PARTITION TYPES.

DOOR TO HAVE DUST/SOUND SEALS AND LOCKABLE DOOR HARDWARE.

REMOVE AT COMPLETION OF CONSTRUCTION. REPAIR ANY DAMAGED

FINISHES FROM PARTITION REMOVAL.

106 SALVAGE SMART BOARD SYSTEM AND RETURN TO CONTRACTING

OFFICER.

108 REMOVE WOOD CHAIR RAIL FROM ALL WALLS, TYPICAL

120 REMOVE ELECTRICAL PANELS AND ASSOCIATED CONDUIT, REFER TO

ELECTRICAL DRAWINGS.

146 REMOVE ACOUSTIC PANELS, WOOD CHAIR RAIL, AND PREPARE WALL FOR

PAINT

150 ELECTRICAL DISPLAY TO REMAIN IN PLACE; PROTECT DURING

CONSTRUCTION.

161 REMOVE ELECTRICAL EQUIPMENT, REFER TO ELECTRICAL

172 REMOVE CONCRETE CURB. SAW CUT TO BE FLUSH WITH EXISTING

CONCRETE FLOOR.

' ' 000

TRUE NORTHTRUE NORTH

1 1

1 1

A

M E

N D

M E

N T

B

ID

D E

R I N

Q U

IR

IE

S

N

O V

11/21/2025

W

2Q R

BA

1_

Pl an s-

UP

COMPUTER

RM

C D E F G H

11.8

UP

M A

T C

H L

IN

E

R E

F E

R A

A

D

M A

T C

H L

IN

E

R E

F E

R A

A

D

ELECTRICAL

TRASH /

RECYCLE

AD201

E5

014025

056056056056 056056 056 056

014025

014 025

014025

014 025

014 025

014 025

097 012

014025

014 025

078333

FLIGHT

SAFETY

PARTS

STOR

MECH

CONFERENCE

RM

CC

ADMIN

DEPUTY

RESOURCE

ADVISOR

STOR

HALL

FLT

SAFETY

MAINT

SUPER

FLT

SAFETY

PARTS

STORAGE

STAIR

FLT

SAFETY

TECH

HALL

1178 PRINTER/FAX

025025014054

014 025

054 014

040 040

172120

120120

097097

161 068

333333

I J K L M N

M A

T C

H L

IN

E

R E

F E

R D

A

D

TRASH /

RECYCLE

COMM

ELEV

LOBBY

ELEC

ELEVATOR

MACHINE

ROOM

STAIR 3

AD201

C5

AD201

A1

AD201

A4

097 097

014 025

029 029029014025 014025

057 057

012 057 012

056 056 056

GEN

STORAGE

ORDERLY

ROOM

014 025

056 056

056 056056

014025054

EXEC

OFFICER

PERSONELIST

SELF

INSPECTOR

1150.1

CAREER

ADVISOR

STOR

MECH

WOMEN'S

MEN'S

SHOWER

1155.1

GARAGE

STAIR

MECH

WOMEN'S

SHOWER

1154.1

MEN'S

GEN

STORAGE

1156.2

GEN

STORAGE

1156.1

HALL

HALL

PRINTER/FAX

E X

IS

T

IN

G

C

O N

S T

R U

C T

IO

N

L

IM

IT

E

D W

O

K

T

H

IS

A R

E A

R E

N O

V A

T

IO

N S

C O

P E

F W

O R

K I

N T

H

IS

A R

A

120120

055055

(ABOVE)

AREA OF EXIST MASONRY WALL TO

BE REMOVED; REFER TO STRUCT

FOR NEW LINTELS

APPROX LOCATION AND SIZE OF

CONC FLOOR SLAB TO BE REMOVED

FOR NEW WORK. RE: MEP AND

STRUCT FOR BACK-FILL. BACK-FILL

TO ALIGN WITH EXIST FACE OF SLAB.

EXISTING PARTITION TO BE REMOVED

REMOVE EXISTING DOOR AND

DOOR FRAME SYSTEM, UNO

LEGEND

EXISTING PARTITION TO REMAIN

R E

G I S

T

ERED ARCH

IT

E

C T

S T

A T E

O F T EX

A S

M A T

TH

EW THOMAS

H A

R E

2 2 8 5 3

164 8268

SCALE: 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

G H

J A

C O

B S

G O

V E

R N

M E

N T

S E

R V

IC

E

S C

O

T e xa s R e g is te re d E n g in e e ri n g F ir m

F -2

M a in

S tr e e t, F o rt

W o rt h

T X

F

IL

E N

A M

E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

R E

P A

IR

S

Q U

A D

R O

N O

P E

R A

T

IO

N S

B L D

G

H A

N G

A R

W E

S T

O V

E R

A R

B M

A U

S A

C E

P

A F

P R

O J E

C T

Y

T P

M

-0

CERTIFIED FINAL

AREAS G&H

KEY PLANKEY PLAN

V S

A R

O N

I

G

IN

G L

IS

M H

A R

E

M H

A R

E

J a c o b s P ro j.

N o

L

D A

R

D

E C

AD112

P A

R T

IA

L

D E

M O

L

IT

IO

N

P L A

N S

L E

V E

L

A

R E

A S

G A

N D

H

Y T

P M

-0

-A

D

SCALE 1/8" = 1'-0"D6

PARTIAL DEMOLITION PLAN - LEVEL 1 - AREA G

SCALE 1/8" = 1'-0"A6

PARTIAL DEMOLITION PLAN - LEVEL 1 - AREA H

GENERAL NOTES - DEMO PLANS

A REFER TO GI003 FOR ABBREVIATIONS.

B REFER TO A-001 FOR GENERAL NOTES, GENERAL DEMOLITION PLAN

NOTES, AND SYMBOLS.

C REFER TO AD140 EXISTING ROOM FINISH SCHEDULE.

D FF&E REMAINING AFTER GOVERNMENT PERSONNEL MOVE OUT WILL BE

REMOVED FROM BUILDING AND DISPOSED OF BY THE GENERAL

CONTRACTOR.

E REMOVE FURRING PARTITION AT EXTERIOR WALLS. EXTERIOR MASONRY

WALL TO REMAIN. CLEAN AND PREP FOR APPLICATION OF FLUID APPLIED

AIR BARRIER. TYPICAL AT ALL EXTERIOR WALLS.

KEYNOTES

003 REMOVE DOOR AND FRAME SYSTEM. INFILL WALL, REFER TO PLANS.

010 CEILING ABOVE TO REMAIN, REPAIR AS NEEDED AND PROTECT DURING

CONSTRUCTION.

012 REMOVE GYPSUM BOARD FURRING AROUND STEEL STRUCTURE.

PROTECT STRUCTURE DURING CONSTRUCTION.

014 REMOVE ALL FLOOR FINISHES AND BASE TRIM IN THIS AREA.

025 REMOVE CEILING, LIGHTING, DIFFUSERS, AND ASSOCIATED CEILING

MOUNTED EQUIPMENT IN THIS AREA. REFER TO MECHANICAL AND

ELECTRICAL

026 REMOVE WALK-OFF MAT.

029 SALVAGE DISPLAY CASE AND OR MARKER BOARD; RETURN TO

CONTRACTING OFFICER.

030 SALVAGE WALL-MOUNTED FLAT TELEVISION AND RETURN TO

CONTRACTING OFFICER.

039 REMOVE FLOOR FINISHES FROM EXISTING STAIR, TYPICAL.

040 ELECTRICAL AND MECHANICAL EQUIPMENT TO REMAIN IN THIS AREA,

PROTECT DURING CONSTRUCTION. REFER TO MECHANICAL AND

ELECTRICAL

041 THE EXISTING C-5 TRAINING SIMULATOR ENCLOSURE IN THE CENTRAL

BAY IS TO REMAIN IN PLACE AND MUST REMAIN IN OPERATION DURING

CONSTRUCTION. PROTECT C-5 SIMULATOR AND ALL UTILITIES THAT

SERVICE IT DURING CONSTRUCTION. ANY DISRUPTIONS IN UTILITY

SERVICES TO THE C-5 SIMULATOR AND HANGAR 1 MUST BE

COORDINATED WITH THE CONTRACTING OFFICER A MINIMUM OF 15

CALENDAR DAYS IN ADVANCE.

042 REMOVE PORTION OF WALL TO ALLOW FOR ACCESS TO INSTALL

PREFINISHED ALUMINUM WINDOWS, REFER TO PLANS. TYPICAL

048 REMOVE LOUVER IN WALL AND INFILL OPENING, REFER TO FLOOR PLANS.

053 REFINISH WOOD HANDRAILS. CLEAN AND PREPARE METAL RAILINGS AND

STAIRS FOR PAINT. REPLACE MISSING DECORATIVE TRIM. REFER TO

INTERIORS FOR FINISHES.

054 REMOVE VINYL WALLCOVERING FROM WALLS AND PREPARE WALL FOR

PAINT, TYPICAL

055 REMOVE METAL FLOOR GRATE AND INFILL OPENING IN FLOOR.

CONCRETE BACKFILL TO BE FLUSH WITH FACE OF EXISTING STRUCTURE.

REFER TO STRUCTURAL FOR FLOOR INFILL DETAIL.

056 REMOVE WINDOW AND/OR DOOR SYSTEM AND INTERIOR WINDOW SILL.

EXTERIOR WINDOW SILL TO REMAIN; PROTECT.

057 REMOVE AND DISPOSE DEMOUNTABLE PARTITIONS

066 REMOVE FLOOR DRAIN, INFILL HOLE IN FLOOR WITH CONCRETE TO BE

FLUSH WITH FACE OF EXISTING SLAB. REFER TO PLUMBING.

068 REMOVE FURRING PARTITION AT EXTERIOR WALLS. EXTERIOR MASONRY

WALL TO REMAIN. CLEAN AND PREP FOR APPLICATION OF FLUID APPLIED

AIR BARRIER. TYPICAL AT ALL EXTERIOR WALLS.

073 REMOVE PLUMBING FIXTURES, REFER TO PLUMBING

078 REMOVE FIRE EXTINGUISHER CABINET; PATCH AND REPAIR WALL

079 REPLACE EXISTING DOOR WITH NEW HM DOOR WITHOUT HOLES FOR

HARDWARE, UNDER CUT DOOR 1", AND WELD SHUT, PREPARE FOR

PAINT. INFILL EXISTING OPENING, REFER TO DETAIL A3/A-620

091 REMOVE AND REPLACE TOILET, ASSOCIATED ACCESSORIES, AND TOILET

PARTITION. REFER TO PLANS, AND INTERIORS FOR FINISHES.

097 REMOVE BASE HEATERS, TYPICAL, RE: MECHANICAL

120 REMOVE ELECTRICAL PANELS AND ASSOCIATED CONDUIT, REFER TO

ELECTRICAL DRAWINGS.

161 REMOVE ELECTRICAL EQUIPMENT, REFER TO ELECTRICAL

172 REMOVE CONCRETE CURB. SAW CUT TO BE FLUSH WITH EXISTING

CONCRETE FLOOR.

333 REMOVE MECHANICAL EQUIPMENT, REFER TO MECHANICAL.

' ' 000

TRUE NORTH

A

M E

N D

M E

N T

B

ID

D E

R I N

Q U

IR

IE

S

N

O V

11/21/2025

W

2Q R

BA

1_

Pl an s-

C D E F G H

11.8

M A

T C

H L

IN

E

R E

F E

R A

A

D

AD201

E5

056 056 056 056 056

056056056

030 029

COPY/FAX

SITE

MGR

CBT RM

INSTRUCTOR'S

OFFICE

WAITING

RM

GEN

STOR

BREAK

TEST

INSTRUCTOR

CLASS

RM

CLASS

RM

CLASS

RM

CLASS

RM

CLASS

RM

LOADMASTER

INSTRUCTOR

OFFICE

GEN

STOR

MECH

2204.1

HALL

STAIR

HALL

HALL

HALL

I J K L M N

M A

T C

H L

IN

E

R E

F E

R D

A

D

AD201

C5

AD201

A1

AD201

A4

056056056056056056056056

080 080 080

COPY/FAX

SITE

MGR

CBT

CURRENT

OPS

STOR

MECH

MEN'S

CC

1ST SGT

HALL

HALL

2253 STAIR

CLOS

STUDY

TRAINING

MECH

JC

MECH

E X

IS

T

G

C

N

S T

R U

C T

IO

N

L

IM

IT

E

D W

O

K

H

IS

A R

E A

R E

N O

V A

T

IO

N S

C O

P

W

O R

K I

N T

H

IS

A R

A

025 014

025014

031036

073011

025 014

025014

AREA OF EXIST MASONRY WALL TO

BE REMOVED; REFER TO STRUCT

FOR NEW LINTELS

APPROX LOCATION AND SIZE OF

CONC FLOOR SLAB TO BE REMOVED

FOR NEW WORK. RE: MEP AND

STRUCT FOR BACK-FILL. BACK-FILL

TO ALIGN WITH EXIST FACE OF SLAB.

EXISTING PARTITION TO BE REMOVED

REMOVE EXISTING DOOR AND

DOOR FRAME SYSTEM, UNO

LEGEND

EXISTING PARTITION TO REMAIN

R E

G I S

T

ERED ARCH

IT

E

C T

S T

A T E

O F T EX

A S

M A T

TH

EW THOMAS

H A

R E

2 2 8 5 3

164 8268

SCALE: 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

G H

J A

C O

B S

G O

V E

R N

M E

N T

S E

R V

IC

E

S C

O

T e xa s R e g is te re d E n g in e e ri n g F ir m

F -2

M a in

S tr e e t, F o rt

W o rt h

T X

TRUE NORTH

F

IL

E N

A M

E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

R E

P A

IR

S

Q U

A D

R O

N O

P E

R A

T

IO

N S

B L D

G

H A

N G

A R

W E

S T

O V

E R

A R

B M

A U

S A

C E

P

A F

P R

O J E

C T

Y

T P

M

-0

CERTIFIED FINAL

AREAS G&H

KEY PLANKEY PLAN

V S

A R

O N

I

G

IN

G L

IS

M H

A R

E

M H

A R

E

J a c o b s P ro j.

N o

L

D A

R

D

E C

AD122

P A

R T

IA

L

D E

M O

L

IT

IO

N

P L A

N S

L E

V E

L

A

R E

A S

G A

N D

H

Y T

P M

-0

-A

D

SCALE 1/8" = 1'-0"D5

PARTIAL DEMOLITION PLAN - LEVEL 2 - AREA G

SCALE 1/8" = 1'-0"A5

PARTIAL DEMOLITION PLAN - LEVEL 2 - AREA H

GENERAL NOTES - DEMO PLANS

A REFER TO GI003 FOR ABBREVIATIONS.

B REFER TO A-001 FOR GENERAL NOTES, GENERAL DEMOLITION PLAN

NOTES, AND SYMBOLS.

C REFER TO AD140 EXISTING ROOM FINISH SCHEDULE.

D FF&E REMAINING AFTER GOVERNMENT PERSONNEL MOVE OUT WILL BE

REMOVED FROM BUILDING AND DISPOSED OF BY THE GENERAL

CONTRACTOR.

E REMOVE FURRING PARTITION AT EXTERIOR WALLS. EXTERIOR MASONRY

WALL TO REMAIN. CLEAN AND PREP FOR APPLICATION OF FLUID APPLIED

AIR BARRIER. TYPICAL AT ALL EXTERIOR WALLS.

KEYNOTES

008 REMOVE WALL MOUNTED AIR CONDITIONING WINDOW UNIT; RETURN TO

CONTRACTING OFFICER. INFILL OPENING IN WALL TO MATCH EXISTING

ADJACENT WALLS.

011 REMOVE PORTION OF WALL FOR NEW DOOR, REFER TO FLOOR PLAN

012 REMOVE GYPSUM BOARD FURRING AROUND STEEL STRUCTURE.

PROTECT STRUCTURE DURING CONSTRUCTION.

014 REMOVE ALL FLOOR FINISHES AND BASE TRIM IN THIS AREA.

023 REMOVE JANITOR SINK AND WALL MOUNTED ACCESSORIES. REFER TO

PLUMBING.

024 SALVAGE OVERHEAD PROJECTION SYSTEM; RETURN TO CONTRACTING

OFFICER.

025 REMOVE CEILING, LIGHTING, DIFFUSERS, AND ASSOCIATED CEILING

MOUNTED EQUIPMENT IN THIS AREA. REFER TO MECHANICAL AND

ELECTRICAL

029 SALVAGE DISPLAY CASE AND OR MARKER BOARD; RETURN TO

CONTRACTING OFFICER.

030 SALVAGE WALL-MOUNTED FLAT TELEVISION AND RETURN TO

CONTRACTING OFFICER.

031 REMOVE TILE FLOOR, WAINSCOT, TOILET PARTITIONS, AND ACCESSORIES

036 REMOVE HVAC VENT/DUCTWORK; REFER TO MECHANICAL.

039 REMOVE FLOOR FINISHES FROM EXISTING STAIR, TYPICAL.

045 DEMOLISH PORTION OF EXISTING +/- 13'-0" TALL MASONRY WALL TO 3'-6"

AFF, AND PREP FOR NEW CAP

049 STEEL COLUMNS TO REMAIN. CLEAN OFF ANY LOOSE PAINT AND

PREPARE FOR NEW FINISHES, REFER TO PLANS.

053 REFINISH WOOD HANDRAILS. CLEAN AND PREPARE METAL RAILINGS AND

STAIRS FOR PAINT. REPLACE MISSING DECORATIVE TRIM. REFER TO

INTERIORS FOR FINISHES.

056 REMOVE WINDOW AND/OR DOOR SYSTEM AND INTERIOR WINDOW SILL.

EXTERIOR WINDOW SILL TO REMAIN; PROTECT.

059 REMOVE WALL MOUNTED METAL ACCESS LADDER AND PATCH HOLES IN

WALL

068 REMOVE FURRING PARTITION AT EXTERIOR WALLS. EXTERIOR MASONRY

WALL TO REMAIN. CLEAN AND PREP FOR APPLICATION OF FLUID APPLIED

AIR BARRIER. TYPICAL AT ALL EXTERIOR WALLS.

073 REMOVE PLUMBING FIXTURES, REFER TO PLUMBING

078 REMOVE FIRE EXTINGUISHER CABINET; PATCH AND REPAIR WALL

080 REMOVE STEEL PIPE RAILING. EXISTING CONC CURB TO REMAIN. PATCH,

FINISH, AND PAINT EXPOSED FACE OF CONC CURB

120 REMOVE ELECTRICAL PANELS AND ASSOCIATED CONDUIT, REFER TO

ELECTRICAL DRAWINGS.

143 ROOF BELOW; REFER TO AD130.

333 REMOVE MECHANICAL EQUIPMENT, REFER TO MECHANICAL.

335 REMOVE STEEL ACCESS STAIRS TO EXTENTS SHOWN. ANCHOR

REMAINING STAIRS TO STEEL STRUCTURE ABOVE, PROTECT REMAINING

STAIRS DURING CONSTRUCTION. REFER: G8/AD210.

351 EXISTING ROOF BELOW.

' ' 000

A

M E

N D

M E

N T

B

ID

D E

R I N

Q U

IR

IE

S

N

O V

11/21/2025

W

2Q R

BA

1_

Pl an s-

M M

G H I J K L M NJ.1 K.1 L.1 M.1 M.9I.1G.6G.2

7.5

STORAGE

STORAGE

COPY/BREAK

SITE

MGR

VTRAT

FLIGHT

SAFETY

SUPR

INSTRUCTORS

FLIGHT

TECHS

COPY

TRAINING

TRAINING

TRAINING

TRAINING

10'-3"

UC2

USH1

ETB5 ETB5 ETB5 ETB5 ETB5

ETB5 ETB5 ETB5 ETB5 ETB5

UMC1

UL1

ECH1

ECH1

ECH1

ECH1

UTV6

ETB4

UAV3

UTV3

UTV4

UTV5

UAV2

ETB6

ECH1

ECH2

ECH2

ECH2

UAV1 ECH1ECH1 ECH1 ECH1 ECH1

ECH1ECH1ECH1ECH1ECH1

ECH2

ECH2 ECH2

ECH2

ETB4

ECH1

ECH1

UST1

EST1

EST2

EST1

UTV1

EMB1

ED3

ED3

ED3

ED3

ED3

ECH1

ECH1

ECH1

ECH1

ECH1ECH1

ECH1

ED2 ED2 ED2

ECH2

ECH2

ECH2

ECH2

ECH2

ECH2

ECH2

ECH2

ECH2 ECH2

ECH2ECH1

TRAINING

TRAINING

UTV2

ETB3

ED1

ECH1

EST1

ETB3

ED1

ECH2

ECH1

ETB2

EQ7

UCBT1

UCBT1

UCBT1

UCBT1

UAP1 UAP2 UAP3 UAP4ETB7

ECH2

R E

G I S

T

ERED ARCH

IT

E

C T

S T

A T E

O F T EX

A S

M A T

TH

EW THOMAS

H A

R E

2 2 8 5 3

164 8268

SCALE: 1/8"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J A

C O

B S

G O

V E

R N

M E

N T

S E

R V

IC

E

S C

O

T e xa s R e g is te re d E n g in e e ri n g F ir m

F -2

M a in

S tr e e t, F o rt

W o rt h

T X

TRUE NORTH

F

IL

E N

A M

E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

R E

P A

IR

S

Q U

A D

R O

N O

P E

R A

T

IO

N S

B L D

G

H A

N G

A R

W E

S T

O V

E R

A R

B M

A U

S A

C E

P

A F

P R

O J E

C T

Y

T P

M

-0

CERTIFIED FINAL

V S

A R

O N

I

G

IN

G L

IS

M H

A R

E

M H

A R

E

J a c o b s P ro j.

N o

L

D A

R

D

E C

AE170

IN

T

E R

IO

R

T E

M P

O R

A R

Y C

U S

T O

M E

R F

A C

IL

IT

Y P

L A

N

Y T

P M

-0

-A

E

SCALE 1/8" = 1'-0"A7

INTERIOR TEMPORARY CUSTOMER FACILITY PLAN

KEYNOTES

162 WALL MOUNTED COMM EQUIPMENT, REFER TO TELECOMM

GENERAL NOTES - TEMPORARY TRAILERS

A TRAILER LAYOUTS ARE BASED ON EXISTING FURNITURE.

REFER TO SHEETS ID140 THRU ID145 FOR LOCATION OF

EXISTING FURNITURE. REFER TO SHEET ID145 FOR

EXISTING FURNITURE SCHEDULE. CONFIRM USER

PROVIDED ITEMS WITH USER BEFORE DEMOLITION.

B FURNITURE IS CFCI UNLESS OTHERWISE NOTED. REFER TO

SPEC SECTION: 01 50 00 TEMPORARY FACILITIES AND

CONTROLS FOR BASIS OF DESIGN.

C CONTRACTOR TO VERIFY FURNITURE REQUIREMENTS AND

LAYOUT WITH CONTRACTING OFFICER.

D FOR ADDITIONAL INFORMATION REFER TO SPEC SECTION:

01 52 00 TEMPORARY CUSTOMER FACILITIES AND

CONTROLS.

E PROVIDE WALL BLOCKING FOR ALL WALL MOUNTED TVS,

MONITORS, AND MARKERBOARDS.

' ' 000

FURNISHED TEMPORARY TRAILER FURNITURE SCHEDULE

ITEM

CODE ITEM DESCRIPTION NOTES

ECH1 CHAIR, TASK CFCI FULLY ADJUSTABLE TASK CHAIR

ECH2 CHAIR, TRAINING CFCI TRAINING CHAIR

ED1 DESK, L-SHAPED CFCI L-SHAPE DESK WITH SURFACE MOUNTED OVERHEAD STORAGE AND B/B/F

ED2 DESK, 30" X 60" CFCI WORKTABLE WITH OVERHEAD SHELVES

ED3 DESK, 36" x 66" CFCI

EMB1 MARKER BOARD CFCI

EQ7 VTRAT EQUIPMENT GFCI EQUIPMENT

EST1 STORAGE, LAT FILE 5H CFCI

EST2 STORAGE,CABINET 24" x 36" CFCI

ETB2 TABLE, 30" x 54" CFCI

ETB3 TABLE, 30" x 60" CFCI

ETB4 TABLE, 36" x 72" CFCI

ETB5 TABLE, 30" x 48" CFCI GANGING TRAINING TABLE WITH WIRE MANAGEMENT TROUGH BELOW. (2) POWER & (1)

DATA ACCESSIBLE FROM TABLE TOP.

ETB6 TRAINING TABLE, 42"X96" CFCI

ETB7 TABLE, 72" X 24" CFCI TABLE TO ACCOMODATE USER PROVIDED BREAK ROOM APPLIANCES.

UAP1 REFRIGERATOR GFCI EQUIPMENT

UAP2 MICROWAVE GFCI EQUIPMENT

UAP3 TOASTER GFCI EQUIPMENT

UAP4 COFFEE MAKER GFCI EQUIPMENT

UAV1 AV CART GFCI EQUIPMENT

UAV2 AV CART GFCI EQUIPMENT

UAV3 AV CART GFCI EQUIPMENT

UC2 COPIER GFCI EQUIPMENT

UCBT1 CBT CARREL GFCI EQUIPMENT

UL1 LECTERN GFCI EQUIPMENT

UMC1 MAIL CART, 18" x 32" GFCI EQUIPMENT

USH1 SHREDDER GFCI EQUIPMENT

UST1 STORAGE, SAFE GFCI EQUIPMENT

UTV1 MONITOR PROVIDE WALL BLOCKING. GFCI MONITOR WITH BRACKET

UTV2 MONITOR PROVIDE WALL BLOCKING. GFCI MONITOR WITH BRACKET

UTV3 MONITOR PROVIDE WALL BLOCKING. GFCI MONITOR WITH BRACKET

UTV4 MONITOR PROVIDE WALL BLOCKING. GFCI MONITOR WITH BRACKET

UTV5 MONITOR PROVIDE WALL BLOCKING. GFCI MONITOR WITH BRACKET

UTV6 MONITOR PROVIDE WALL BLOCKING. GFCI MONITOR WITH BRACKET

11 1

DUPLICATE NOTES OMITTED

A

M E

N D

M E

N T

B

ID

D E

R I N

Q U

IR

IE

S

N

O V

11/21/2025

W

2Q R

BA

1_

Pl an s-

C1

ACCESSIBLE HIGH-LOW

ELECTRIC WATER COOLER

R E

P

L A

N S

RE: PLANS

R E

R

C P

M A

X

EWC-1

EWC-1

CEILING,

AS

SCHED

2'-6" X 4'-0"

CLEAR

FLOOR

SPACE

SPOUT

SPOUT

BOTTLE

FILLING

STATION

M

IN

ELECTRIC WATER

COOLER: THE SPOUT

SHALL PROVIDE

A FLOW OF WATER 4"

HIGH. CONTROLS SHALL

BE FRONT MOUNTED

EWC - 1

J1 STANDARD JANITORS CLOSET

USMH - 1

MS - 1

SSF - 1

USMH - 1

SSF - 1

FMS - 1

USMH-1 HEAVY DUTY SHELF WITH MOP

HOLDERS AND RAG HOOKS

8"X36"

MS-1 FLOOR MOUNTED UTILITY SINK,

2'-0" X 3'-0"

SSF-1 FAUCET WITH BUCKET HOOK,

TOP BRACE, VACUUM BREAKER,

HOSE THREADS

SD-1

MG-1

1' - 3" EQ EQ 1' - 3"

RE: PLAN

SD-1

2'-6"x 4'-0"

CLEAR FLOOR

SPACE

L- 1

ABA APRON

RE: INTERIORS

WALL MOUNTED SOAP DISP, STOKO

REFRESH DISPENSER 1000

ACCESSIBLE UNDER COUNTER MOUNTED

LAVATORY

MG - 1 MIRROR - FULL WIDTH

SD- 1

L2 ACCESSIBLE MULTIPLE

COUNTER MOUNTED LAVATORIES (3 EQ SPACED)

M A

X

EQ EQ EQ EQ

L-1

L-1

L-1

L- 1 ACCESSIBLE UNDER

COUNTER MOUNTED

LAVATORY

L1 ACCESSIBLE MULTIPLE

COUNTER MOUNTED LAVATORY

1' - 3" RE: PLAN 1' - 3"

SD-1

ABA APRON

RE: INTERIORS

MG-1

2'-6" x 4'-0"

CLEAR

FLOOR

SPACE

" SD-1

L-1

SD- 1 WALL MOUNTED SOAP

DISP, STOKO REFRESH

DISPENSER 1000

MG - 1 MIRROR - FULL WIDTH

EQ EQ

M A

X

EQ EQ

L-1

1" 3' - 0" 1"

1' - 6" 1' - 6"

WC-1

TTD-1

CH-1

S1

STANDARD

STALL

TSCD-1

TSCD-1

TTD-1

SURFACE MOUNTED TOILET

SEAT COVER DISPENSER;

BOBRICK; B-4221

SURFACE MOUNTED TOILET

PAPER DISPENSER BAY WEST:

80300

6" 2' - 0" 6"

WC-1 STANDARD TOILET

COAT HOOK BUMPER; SOLID

CAST ALUMINUM; BOBRICK: B- 211

CH-1

SND-1

TTD-1

SANITARY NAPKIN DISPOSAL

(UNISEX/WOMEN'S RR ONLY)

SND-1

M

IN

M A

X

WC-2

TTD-1

GB-1

CH-1

DB-1

TTD-1

S2 END OF ROW

ACCESSIBLE STALL

SURFACE MOUNTED

TOILET PAPER DISPENSER

BAY WEST: 80300

WC-2

LOCATE FLUSH

HANDLE ON SIDE

OPPOSITE WALLGB-1

TSCD-1

SURFACE MOUNTED

DOOR BUMPER,

CENTER ON DOOR,

BOBRICK: B-687

TTD-1

DB-1

COAT HOOK BUMPER; SOLID

CAST ALUMINUM; BOBRICK:

B- 211

CH-1 GRAB BAR L SHAPE

BOBRICK: B-68137

GB-1

ACCESSIBLE TOILETWC-2

TSCD-1 SURFACE MOUNTED

TOILET SEAT

COVER DISPENSER;

BOBRICK; B-4221

LOCATE TOILET

DIAGONALLY FROM

DOOR OPENING

WC-2

3'-0"

MAX

16"-18"

M A

X

4" 2'-8" 2'-0"

5'-0"

"M

A X

M A

X

SNTD - 1

TSCD - 1

SNTD - 1 SURFACE MOUNTED SANITANY

NAPKIN/TAMPON VENDOR,

BOBRICK: B - 282 25

TSCD - 1 RECESSED TOILET SEAT-COVER

DISPENSER, BOBRICK: B - 301

MISCELLANIOUS TOILET ROOM

MOUNTING HEIGHTS

H E

IG

H

T O

F F

F L O

O R

R E

C O

M M

E N

D E

D M

O U

N T

IN

G

HD-1

HD-1 RECESSED ELECTRIC

HAND DRYER (NO TOUCH),

R E

C O

M M

E N

D E

D M

O U

N T

IN

G

H E

IG

H

T O

F F

F L O

O R

SURFACE MOUNTED PAPER TOWEL

DISPENSER, BAY WEST: 89500

PTWR-1

PTWR-

M A

X

TOILET STALL NOTES:

1. REFER TO PLAN FOR

QUANTITIES AND

ORIENTATION

OF TOILET PARTITIONS AND

URINAL SCREENS

P1 STANDARD FLOOR MOUNTED

PRT-1 1" THICK SOLID TOILET

PARTITION AS SPECIFIED,

REFER TO INTERIORS.

U-1 1" THICK SOLID URINAL

SCREEN AS SPECIFIED,

REFER TO INTERIORS.

CH-1 CLOTHES HOOK AND

BUMPER CENTER ON

DOOR; BOBRICK: B-212

DB-1 DOOR BUMPER; BOBRICK:

B-687

1' - 6"

U-1

DB-1

PRT-1 PRT-1

CH-1

TOILET PARTITIONS

U1

U2 SC1

U1 U2

SC1

RIM

RIM

2'-6" (U-2)

3'-0" (U-1)

EQ EQ

U1

U2

STANDARD URINAL

ACCESSIBLE URINAL

U1 STANDARD URINAL

U2 ACCESSIBLE URINAL

SC1 URINAL SCREEN

R E

G I S

T

ERED ARCH

IT

E

C T

S T

A T E

O F T EX

A S

M A T

TH

EW THOMAS

H A

R E

2 2 8 5 3

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

J A

C O

B S

G O

V E

R N

M E

N T

S E

R V

IC

E

S C

O

T e xa s R e g is te re d E n g in e e ri n g F ir m

F -2

M a in

S tr e e t, F o rt

W o rt h

T X

F

IL

E N

A M

E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

R E

P A

IR

S

Q U

A D

R O

N O

P E

R A

T

IO

N S

B L D

G

H A

N G

A R

W E

S T

O V

E R

A R

B M

A U

S A

C E

P

A F

P R

O J E

C T

Y

T P

M

-0

CERTIFIED FINAL

V S

A R

O N

I

G

IN

G L

IS

M H

A R

E

M H

A R

E

J a c o b s P ro j.

N o

L

D A

R

D

E C

A-402

R E

S T

R O

O M

A C

C E

S S

O R

IE

S

L E

G E

N D

A N

D M

O U

N T

IN

G

H E

IG

H

T S

Y T

P M

-0

-A

-4

TOILET ACCESSORIES NOTES

A MANUFACTURER PRODUCTS INDICATED

ESTABLISHES A PALLET OF COLORS AND A MINIMUM

LEVEL OF ACCEPTABLE QUALITY. IT IS NOT

INTENDED TO LIMIT THE SELECTION OF APPROVED

EQUIVALENT PRODUCTS.

B REFER TO PLAN FOR QUANTITIES AND ORIENTATION

OF TOILET PARTITIONS AND ACCESSORIES

A

M E

N D

M E

N T

B

ID

D E

R I N

Q U

IR

IE

S

N

O V

11/21/2025

W

2Q R

BA

1_

Pl an s-

AIR-DIFFUSERS W/ (2) 12.

GA. HANGER WIRES AT

ALTERNATE CONERS TO

THE STRUCTURE ABOVE

LIGHT FIXTURE: W/

(4) 12 GA. HANGER

WIRES AT

ALTERNATE

CORNERS TO THE

STRUCTURE ABOVE

NOTE:

LIGHT FIXTURE OR DIFFUSERS IN EXCESS OF 56 LBS.

REQUIRE (4) 12 GA. HANGER WIRES

12 GA. VERT.

HANGER WIRE AT

4'-0" O.C. WITH MIN.

(3) TIGHT TURNS IN 1

1/2"

MAIN

RUNNER

AT 4'-0"

O.C.

BRACED

OFF WALL

CEILING AS

SCHEDULED

MTL STUD HEADER

GYP BD

ALIGN HEADER WITH

WALL BEYOND

VARIES

V A

R

IE

S R

E R

C P

CEILING AS SCHEDULED

V A

R

IE

S

3-5/8" MTL STUD

BRACING AT 48" OC; TYP.

V A

R

IE

S A

T S

IM

LINE OF

STRUCTURE

GYP BD AT SIM

CEILING AS

SCHEDULED

MTL STUD

HEADER

GYP BD

PARTITION AS

SCHEDULED

V A

R

IE

S R

E R

C P

RE: PLANS

3-5/8" MTL STUD BRACING

AT 48" OC; TYP.

CEILING AS

SCHEDULED

MTL STUD

HEADER

GYP BD

ALIGN HEADER

WITH WALL

BEYOND

VARIES

V A

R

IE

S R

E R

C P

CEILING AS SCHEDULED

V A

R

IE

S

3-5/8" MTL

STUD BRACING

AT 48" OC; TYP.

CEILING HEIGHT

PROJECTION MOUNT

PLENUM COVER, SEAL

AROUND PROJECTION

MOUNT AND SECURE

PER MFR'S

SPECIFICATION

CEILING AS SCHEDULED

REFERENCE INTERIORS

FOR PROJECTOR.

UNIVERSAL PROJECTOR

MOUNT WITH 6"

EXTENSION PIPE, SECURE

PER MFR'S SPECIFICATION

METAL BRACING AS

REQUIRED.

R E

M

E C

H P

L U

M B

IN

G

E

L E

C

CONTINUOUS

SEALANT AROUND

PENETRATION ON

BOTH SIDES

FILL VOID AROUND

PENETRATION AND

WALL WITH EXPANSIVE

FOAM INSULATION

/2

M

IN

/2

M

IN

EXISTING EXTERIOR

WALL. CONTRACTOR TO

USE CAUTION AT

LOCATIONS OF EXISTING

EMBEDDED HISTORIC

WINDOWS, RE: PLANS

AND ELEVATIONS.

1 1/2" RUNNER AT

48" O.C.

1 1/2" RUNNER 16"

LONG - NESTED

FURRING CHANNEL,

24" O.C. MAX.

GYP BD CEILING

VINYL CONTROL

JOINT, PAINTED TO

MATCH CEILING

V E

R

IF

Y I N

F

IE

L D

EXIST WINDOW

SILL

ALUM WINDOW

SYSTEM

5/8" GYP BD BOTH

SIDES

BATT INSULATION

PARTITION, RE:

FLOOR PLANS

2-1/2" STL STUDS

CONT NEOPRENE

GASKET

CONT NEOPRENE

GASKET

RE: PLANS

EXISTING WALL

PARTITION TYPE

RE: PLANS FOR

V E

R

IF

Y I N

F

IE

L D

E X

IS

T

IN

G

L O

U V

E R

/G R

IL

L

BACKER ROD

AND SEALANT

2" RIGID INSULATION

SELF ADHERED AIR

BARRIER

TRANSITION

MEMBRANE

FLUID APPLIED AIR

BARRIER

8" CMU INFILL AT

EXIST WALLS OVER

1'-0" THICK

4" CMU INFILL AT

EXIST WALLS

UNDER 1'-0" THICK

FACE OF SEALANT

CMU INFILL ANCHOR,

RE: STRUCTURAL

PROVIDE WEEPS

AT BASE FOR

DRAINAGE

PREFINISHED METAL

WINDOW PANEL

ANCHORED TO 3-5/8"

STL FRAMING AT 12"

OC, USE GASKETED

ANCHORS THAT

MATCH THE FINISH

OF THE PANEL

CEILING HEIGHT

CEILING AS SCHEDULED

PREFINISHED

CEILING EDGE

TRIM

2-1/2"

CH-STUD

1" GYP LINER

PANEL

5/8" GYP BD

SEALANT

BATT

INSULATION

EXISTING

STRUCTURE

2" RIGID

INSULATION

EXISTING

STRUCTURE

LEVEL 03

25' - 5"

CEILING HEIGHT

AS SCHED.

1/2"

2 1/4"

1/4"

2 1/4"

1/2"

/4

MOUNTING JOIST

"L" BRACKET

PICTURE DOOR

SURFACE

MOUNTING

BRACKET

PICTURE

SURFACE

FURRING STRIPS

SUSPENDED

CEILING TILE

ACCESS DOOR

SLAT HOOK

1/4" BOLTS

4"

CLG TILE CUT OUT

1/4" THK (ATTACH

WITH MASTIC)

1/4" x 1" SCREW &

T-NUT

DRYWALL SCREW

T BAR FURNISHED

WITH CLG.

5 3/4"

FIN FLOOR

FLOOR FINISH, RE: INTERIORS

2 LAYERS 1/2" PLYWD T&G

SUBFLOOR, STAGGER JOINTS

1/2" PLYWD

NOSING AND WALL BASE, RE:

INTERIORS

PRESSURE TREATED 2X

WOOD FRAMING AT 16" O.C.

1"

1"

+/- 10"

V A

R

IE

S V

A R

IE

S

ALIGN

TLT

PARTITION

TLT

PARTITION

SUPPORTS

EXTERIOR

WALL

1"

R E

G I S

T

ERED ARCH

IT

E

C T

S T

A T E

O F T EX

A S

M A T

TH

EW THOMAS

H A

R E

2 2 8 5 3

6"6"

SCALE: 3"=1'-0"

04 2

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

This is the start of the file's text. The full file is on GovTribe.