D/B/B CONSTRUCTION: W912QR24R0071 SECURITY FORCES TRAINING FACILITY, DOBBINS AIR RESERVE BASE, GA
Solicitation number
W912QR24R0071
Issued by

About this file

This document is an amendment to a solicitation (W912QR24R0071) for the design-bid-build construction of a Security Forces Training Facility at Dobbins Air Reserve Base in Marietta, Georgia.

The amendment modifies the original solicitation by adding several attachments, including as-built drawings, a basis of design, and an FF&E package. It also replaces two specific plan sheets and extends the proposal response date to September 6, 2024. The overall project involves constructing a 21,464 SF facility with training, administrative, and storage spaces, to be designed as permanent construction in accordance with DoD Unified Facilities Criteria. This is a total small business set-aside with a Firm-Fixed-Price contract, and the NAICS code is 236220 - Commercial and Institutional Building Construction. The Government intends to award without discussions but reserves the right to conduct discussions. The magnitude of the construction project is anticipated to be between $10-25 million.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

Solicitation No. W912QR24R0071 for the Design-Bid-Build Construction of the Security Forces Training Facility at Dobbins ARB in Marietta, GA is hereby modified as follow s:

1. CONTRACT ID CODE PAGE OF PAGES

1 2

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W912QR24R0071

X 9B. DATED (SEE ITEM 11)

01-Aug-2024

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO.

5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

27-Aug-2024

CODE

U. S. ARMY ENGINEER DISTRICT, LOUISVILLE

600 DR. MARTIN LUTHER KING, JR. PLACE

ROOM 821

LOUISVILLE KY 40202-2239

W912QR 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W912QR24R0071_Plans-0001

W912QR24R0071

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 30 - BLOCK 14 CONTINUATION PAGE (SF 30)

The following have been modified:

AMENDMENT 0001

SUMMARY OF CHANGES

1. The following ATTACHMENTS have been added in their entirety for reference only:

Building 701 As-Builts Basis of Design Furniture, Fixtures, & Equipment (FF&E) Package

2. The following PLAN SHEETS have been replaced in their entirety:

FA-002 GENERAL NOTES FIRE ALARM

FA-501 DETAILS FIRE ALARM

3. The PROPOSAL RESPONSE DATE has been extended to:

06 SEPTEMBER 2024, 1:00 PM EDT

(End of Summary of Changes)

FIRE ALARM MASS NOTIFICATION NOTES:

1. THESE DOCUMENTS DEPICT AN ENGINEERING DESIGN LAYOUT TO BE UTILIZED

AS GUIDANCE FOR THE PLANNING OF THE FIRE ALARM/MASS NOTIFICATION

SYSTEM BY THE CONTRACTOR. LAYOUT IS GENERIC AND NOT MANUFACTURER

SPECIFIC. HOWEVER, SYSTEM, FMCP AND TRANSCEIVER MUST BE MONACO.

SCHEMATIC DRAWING MAY BE INCOMPLETE WITH SOME DEVICES NOT SHOWN

OR SEVERAL DEVICES REPRESENTING MORE. PROVIDE COMPLETE

DOCUMENTS FOR REVIEW AND APPROVAL FROM THE COR PRIOR TO

INSTALLATION. PROVIDE A COMPLETE INSTALLATION. PROVIDE DEVICES NOT

SHOWN FOR A COMPLETE FUNCTIONAL SYSTEM LIMITED TO ADDRESSABLE

MONITOR MODULES FOR ALL DEVICES THAT DO NOT HAVE ADDRESS AND

CONTROL MODULES TO CONTROL AUXILIARY FUNCTIONS. PROVIDE A

COMPLETE COMBINATION FIRE ALARM AND MASS NOTIFICATION SYSTEM, AND

INSTALLED IN ACCORDANCE WITH NFPA 72-2022, UFC 3-600-01, UFC 4-021-01,

ADA/ABA AND PROJECT SPECIFICATIONS.

2. PROVIDE AN INTELLIGENT, ADDRESSABLE COMBINATION FIRE ALARM/MASS

NOTIFICATION CONTROL PANEL (FMCP). THE FMCP MUST BE DESIGNED FOR

ACTIVATION OF FIRE ALARM NOTIFICATION, COMMON SIGNALS, ADDRESS

ANNUNCIATION, AND TRANSMISSION TO TRANSCEIVER.

3. PROVIDE BACKBOX AT EACH SPEAKER, STROBE, AND SPEAKER/STROBE

LOCATION.

4. CONTRACTOR SHALL PROVIDE METHOD FOR OVERRIDE OF ALARM FUNCTIONS

DURING PAGING.

5. PROVIDE ADDITIONAL MASS NOTIFICATION OR FIRE ALARM SPEAKERS AS

NECESSARY TO MEET THE AUDIBILITY REQUIREMENTS OF NFPA 72 AND TO

ENSURE THAT A COMMON INTELLIGIBILITY SCALE (CIS) SCORE OF 0.8 IS

PROVIDED IN EACH NORMALLY OCCUPIED AREA OF THE BUILDING.

6. MOUNT ALL WALL-MOUNTED NOTIFICATION APPLIANCES WITH THE BOTTOM OF

THE STROBE LENS AT 80" AFF, OR 6" BELOW THE CEILING (WHICHEVER IS

LOWER) UNO.

7. PROVIDE TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) ON ALL FIRE

ALARM AND MASS NOTIFICATION SYSTEM CIRCUITS ENTERING OR LEAVING THE

FACILITY. ROUTE UNDERGROUND CIRCUITS AND CONDUIT PER NEC ARTICLE

800.

8. MOUNTING OF DEVICES MUST COMPLY WITH NFPA AND ABA/ADA

REQUIREMENTS UNO MOUNT THE OPERABLE PART OF MANUAL PULL, AT 44"

AFF.

9. PROVIDE CLASS B SIGNALING LINE CIRCUITS, CLASS B INITIATING DEVICE

CIRCUITS, AND CLASS B NOTIFICATION APPLIANCE CIRCUITS FOR THE MASS

NOTIFICATION SYSTEMS.

10. PROVIDE NOTIFICATION APPLIANCES FOR FA/MNS SYSTEM WITH WHITE

FACEPLATES AND CLEAR STROBES MARKED WITH "ALERT" IN THE COLOR RED

THROUGHOUT FINISHED AREAS OF THE BUILDING.

11. REFERENCE ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATED

PLACEMENT OF APPLIANCES WITH LOCATIONS OF DIFFUSERS, LIGHTS, AND

OTHER DEVICES.

12. DEVICES ARE DESIGNED TO BE INSTALLED ON BOTH WALLS AND CEILINGS.

COORDINATE ALL WORK PRIOR TO INSTALLATION WITH ALL OTHER TRADES.

13. ALL FIRE ALARM/MASS NOTIFICATION CONTROL PANELS AND UNITS MUST BE

PROVIDED IN YEAR ROUND CONDITIONED SPACES. ALL FIRE ALARM AND MASS

NOTIFICATION CONTROL PANELS SHALL BE INSTALLED A MAXIMUM OF 5 FEET

ABOVE FINISHED FLOOR MEASURED TO CENTERLINE OF THE PANEL.

14. THE MNS MUST BE EQUIPPED FOR BUILDING PAGING.

15. SECONDARY POWER SUPPLY MUST BE SIZED TO PROVIDE THE GREATER OF 48

HOURS OF STANDBY TIME, AN ADDITIONAL 15 MINUTES OF ALARM/FULL LOAD

TIME FOR FIRE ALARM SYSTEM AND 60 MINUTES OF NOTIFICATION ON THE MNS.

16. POWER CIRCUITS FOR FIRE ALARM CONTROL PANEL AND FIRE ALARM SYSTEM

POWER MUST BE ON A DEDICATED 120V AND SHALL HAVE A RED MARKING,

LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT".

17. PROVIDE ADDRESSABLE DOUBLE ACTION PULL STATIONS AT EACH EXIT DOOR,

INCLUDING MECHANICAL ROOMS, ELECTRIC ROOMS, AND OTHER ROOMS AS

SHOWN ON DRAWINGS. MANUAL PULL STATIONS SHALL NOT NEED GLASS

RODS.

18. SEAL ALL PENETRATIONS THROUGH FIRE RATED PARTITIONS OR BARRIERS

WITH UL LISTED THROUGH PENETRATION FIRE STOP SYSTEM, PROVIDING A

FIRE RATING EQUAL OR GREATER THAN THE FIRE RATED BARRIER.

19. ALL FIRE ALARM AND MASS NOTIFICATION SYSTEM WIRING MUST BE SOLID

COPPER (UNO). ALL FIRE ALARM CIRCUITS MUST BE PULLED SPLICE FREE,

WHERE CONNECTIONS ARE UNAVOIDABLE CONNECTIONS MUST BE MADE WITH

THERMALLY INSULTED SCREW TYPE TERMINAL STRIPS.

20. DUCT DETECTORS (IF INSTALLED) MUST BE INSTALLED IN ACCORDANCE WITH

MANUFACTURER'S RECOMMENDATIONS FOR STRAIGHT DUCT LENGTHS, ALL

SAMPLING TUBES SHALL COVER THE ENTIRE WIDTH OF THE DUCT ASSEMBLIES.

21. VISUAL DEVICES ARE REQUIRED IN ALL PUBLIC USE AREAS, COMMON USE

AREAS AND EMPLOYEE WORK AREAS TO INCLUDE OFFICE SUITES AND AREAS

INTENDED TO HAVE MORE THAN ONE DESK/ OCCUPANT.

22. FIRE ALARM CONTROL PANEL WILL REQUIRE 4FT OF WALL SPACE.

23. ALL NEW CONDUIT IS TO BE FACTORY PAINTED RED.

24. THE CONTRACTOR MUST PAINT ALL NEW CONVER PLATES FOR THE FIRE

ALARM CONDUIT JUNCTION BOXES RED. THE COVERS MUST BE PROPERLY

CLEANED PRIOR TO PAINTING. PROVIDE TWO COATS OF FACTORY APPLIED

ENAMEL PAINT.

25. THIS BUILDING IS CLASSIFIED AS A C2 BUILDING. THE BUILDING WILL BE

PROVIDED WITH SMALL VOICE INSIDE THE BUILDING FROM THE GIANT VOICE

NETWORK.

26. SYSTEM, FMCP AND TRANSCEIVER SHALL BE MONACO.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

T E

T R

A T

E C

H

IN

C

W a rr in g to n W a y

L o u is v ill e

K Y

P h o n e

-5 w w w .t e tr a te c h .c o m

M e d lo ck B ri d g e

R D

S T

E

Jo h n s

C re ek

G A

P h on e (4

-6

FA-002

G e n e ra l N o te s

D O

B B

IN

S

A

IR

R E

V E

R V

E B

A S

E G

A

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J R

P

L A

C E

L O

U

IS

V

IL

L E

K

Y

R H

E S

P R

IC

H

B K

O T

U L A

R H

E S

P R

IC

H

/1

/2

F Y

C E

R T

IF

IE

D F

IN

A

L

F G

W B

-0

S

E C

U R

IT

Y

F O

R C

E S

F A

C

IL

IT

Y

P R

O J E

C T

P

F ir e A la rm

STANDARD FIRE ALARM/MASS NOTIFICATION MESSAGES

No. Activation Name Tone Type Tone Cycles Tone Duration Message Content LED Text Sign Message Loop Duration (UFC

4-021-01)

1 Building Emergency (Evacuate)

Chime (NFPA 72, Figure A.18.4.2.1(b))

2 times before and after message (NFPA 72, 24.4.2.1)

Per NFPA 72, Figure A.18.4.2.1(b)

"May I have your attention please. An emergency has been reported in the building.

Please walk to the nearest exit and leave the building."

Display "Evacuate" and voice message

Continuous, for 10 minutes if overriding fire alarm

2 Area Emergency (Shelter-In-Place)

Chime or 1000 Hz tone 2 times before the message only

3 seconds "May I have your attention please. An emergency has been reported in the area.

Please remain in the building and await further instructions."

Display "Announcement" and voice message

Continuous, for 10 minutes if overriding fire alarm

3 Area Emergency (ATFP Initiatives)

Chime or 1000 Hz tone 2 times before the message only

3 seconds "May I have your attention please. An emergency has been reported in the area. Close doors and windows. Shut off all heating, ventilation, and air conditioning. Seek shelter immediately."

Display "Announcement" and voice message

Continuous, for 10 minutes if overriding fire alarm

4 Severe Thunderstorm Warning

Chime or 1000 Hz tone 2 times before the message only

3 seconds "May I have your attention please. The National Weather Service has issued a SEVERE THUNDERSTORM WARNING for this area; please take immediate shelter indoors."

Display "Announcement" and voice message

Continuous, for 10 minutes if overriding fire alarm

5 Tornado Warning Chime or 1000 Hz tone 2 times before the message only

3 seconds "May I have your attention please. The National Weather Service has issued a TORNADO WARNING for this area; please take immediate shelter in the tornado shelter, basement, or on the lowest level at the center of the building away from exterior windows and doors."

Display "Announcement" and voice message

Continuous, for 10 minutes if overriding fire alarm

6* Fire Alarm (Automatic and Pre-recorded)

Three Pulse Temporal

(NFPA 72, 18.4.2.1)

2 times before and after message (NFPA 72, 24.4.2.1)

Per NFPA 72, Figure 18.4.2.1

"May I have your attention please. An emergency has been reported in the building.

Please walk to the nearest exit and leave the building."

Display "Evacuate" and voice message

Continuous (UFGS 28 31 76)

7 Test Chime or 1000 Hz tone 2 times before and after the message

3 seconds "May I have your attention please. This is a test of the building mass notification system.

Please continue your normal duties. This is only a test."

Display "Announcement" and voice message

Once

8 All Clear Chime or 1000 Hz tone 2 times before and after the message

3 seconds "May I have your attention please. An all clear has been issued, resume normal activities."

Display "Announcement" and voice message

Once

9 Carbon Monoxide Four pulse temporal pattern

2 times before and after the message

3 seconds "May I have your attention please. Carbon Monoxide has been reported in the building.

Please walk to the nearest exit and leave the building."

Display "Evacuate" and voice message

Continuous

10 MNS Microphone (LOC or ACU Keying)

Chime or 1000 Hz tone Once Display "Announcement" and voice message

11 Public Address Microphone

Chime/tone distinctive from MNS/FA messages

Once N/A N/A

Notes:

1. All references to NFPA 72 contained herein are to the 2022 edition.

2. The tones and message content may vary depending upon occupancy type. (i.e. Child Development Centers).

3. All pre-recorded and automatic messages shall utilize a female voice.

4. Modify the evacuation messages for multi-story buildings to restrict the use of elevators, where applicable.

5. Blanks may be used for specific messages that are Base specific, region specific, hazard specific Force Protection conditions, hostile intruder, bomb threat, etc.

6. Sever Thunderstorm and Tornado Warnings shall be modified for region specific weather events.

7. Use a single tone type for all pre-recorded non-fire alarm, non-weather messages unless installation specific criteria exist.

8. LED text signs shall display the word "Evacuate" or Announcement" followed by the content of the pre-recorded or automatic message being played. For live announcements, the LED text sign shall read "Announcement" only.

9. LED text signs shall display the message content by scrolling on the message board bottom to top or right to left. "Announcement" and Evacuate" text may be static or flashing.

*Fire alarm message shall be the lowest priority of the emergency messages according to NFPA 72. Activation of all other MNS emergency messages shall override the fire alarm message.

A

M E

N D

M E

N T

/2 /2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns -0

SHUT

DOW

N R

ESPECTI

VE A

IR

H

ANDLIN

G E

QUIP

M

ENT

REQUIRED FIRE SAFETY CONTROL

ACTU

ATE

A

UDIB

LE

S

UPERVIS

ORY S

IG

NAL

ACTU

ATE

C

OMMON S

UPERVIS

ORY S

IG

NAL I

NDIC

ATO

R

ACTU

ATE

A

UDIB

LE

A

LA

RM S

IG

NAL

ACTU

ATE

C

OMMON A

LA

RM S

IG

NAL I

NDIC

ATO

R

FIRE ALARM SYSTEM LOW BATTERY

AREA SMOKE DETECTORS

CONTROL COMPONENT TROUBLE CONDITION

BUILDING MANUAL PULL STATIONS

MAIN SPRINKLER FLOW SWITCH

CIRCUIT FAULT - FACP

CIRCUIT FAULT - MNS

SPRINKLER TAMPER SWITCH

FIRE ALARM SYSTEM

INPUT/OUTPUT MATRIX

SYSTEM INPUTS

FIRE ALARM SYSTEM AC POWER FAILURE

FACP ANNUNCIATION

ACTU

ATE

Z

ONE O

R D

EVIC

E A

DDRESS A

LA

RM IN

DIC

ATO

R

TRANSMIT

T

ROUBLE

S

IG

NAL T

O C

ENTRAL S

TATIO

N

TRANSMIT

S

UPERVIS

ORY S

IG

NAL

TO C

ENTR

AL S

TA

TIO

N

TRANSMIT

F

IR

E A

LA

RM S

IG

NAL T

O C

ENTRAL S

TATI

ON

ACTU

ATE

A

UDIB

LE

T

ROUBLE

S

IG

NAL

ACTU

ATE

C

OMMON T

ROUBLE

S

IG

NAL I

NDIC

ATOR

SYSTEM OUTPUTS

NOTIFICATION

B CA HGFED LK MI J RQPON T US WV

ACTIVATION OF LOC

MNS MESSAGE SWITCH AT FMCP

ALARM SILENCING SWITCH

SUPERVISORY/TROUBLE SILENCING SWITCH

SILE

NCE A

UDIO

/V

IS

UAL T

ROUBLE

S

IG

NAL

SEE S

PEC

SECTI

ON 28

F

OR A

DDIT

IO

NAL R

EQUIR

EMENTS

SILE

NCE A

UDIO

/V

IS

UAL N

OTI

FIC

ATI

ON. N

OTI

FIC

ATIO

N T

O

RESTA

RT U

PON S

UBSEQUENT

ALA

RM

SHUTD

OW

N A

LL

F

IR

E A

LA

RM N

OTIF

IC

ATI

ON

ACTI

VATE

R

ECORDED M

NS M

ESSAGE

HVAC AIR DUCT SMOKE DETECTORS

CARBON MONOXIDE DETECTOR

FLOW SWITCH IN SERVER ROOM

SHUT

DOW

N S

ERVER R

OOM

TRANSMIT

M

NS O

VERID

E T O C

ENTRAL S

TATIO

N

TRANSMIT

C

ARBON M

ONOXID

E S

IG

NAL T

O C

ENTR

AL

STA

TIO

N

ACTI

VATE

C

ARBON M

ONOXID

E A

LA

RM

ACTI

VATE

V

IS

UAL N

OTIF

IC

ATON/S

TR

OBES

ACTI

VATE

W

ATER F

LO

W

B

ELL

ACTI

VATE

E

GRESS LI

GHTIN

G

SHUT

DOW

N B

ATT

ERY C

HARGER

X

B CA HGFED LK MI J RQPON T US WV X

FLOW SWITCH IN ELECTRICAL ROOM

Y Z AA

ACTI

VATE S

CROLL

IN

G LE

D T

EXT S

IG

NAGE -

EVACUATI

ON

ACTI

VATE

S

CROLL

IN

G LE

D T

EXT S

IG

NAGE -

ANNOUNCEMENT

Y Z AA

DETAIL NOTES:

1. PROVIDE BUILDING TRANSCEIVER (MONACO)

2. PROVIDE A OMNIDIRECTIONAL ANTENNA

THE ANTENNA MUST BE SET TO BASE FREQUENCY.

4. ANTENNA CABLE MUST BE IN RIGID OR EMT RACEWAY.

5. ANTENNA MUST BE PLACED IN CLEAR LINE OF SIGHT WITH SUPERVISING

STATION. COORDINATE LOCATION WITH THE COR.

TRANSCEIVER ANTENNA

1-INCH EMT CONDUIT TO BUILDING GROUND

ENCLOSURE W/

CONNECTION

TO GROUND

1-INCH EMT CONDUIT WITH

ANTENNA CABLE WIRE TO J-BOX.

1 INCH CONDUIT WITH

ANTENNA CABLE

ANTENNA, ATTACH TO 1 INCH

RGS CONDUIT WITH GALVANIZED

OR STAINLESS STEEL STRAPS

STRUCTURAL BRACE (TYP)

PIPE CLAMP (TYP)

PENETRATE WALL WITH 1-1/2 INCH

CONDUIT SLEEVE.

TO TRANSCEIVER

AUD/FA AUD NAC 2

AUD/MNS NAC 1

FIRE ALARM CONTROL

PANEL FMCP (MONACO)

FIRE ALARM RADIO

TRANSCEIVER

RT (MONACO)

BATT

AND MASS COMMUNICATIONS

AUD/MNS NAC 4

AUD/MNS NAC 3

WP

WP

WP

SA

SA

SIGNALING LINE CIRCUIT

SLC

EOL

AUD/MNS NAC 5

WP

WP

NOT ALL DEVICES

ARE SHOWN FOR

CLARITY

TEXTTEXT TEXT

R

CM

CM

MM

MM

MM

F

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

MM

MM

T MM

CONDUCTOR

TO ECC

T

T

T

F

F

S

CO

F

F MM

T MM

120 v

120 v

MM

ANN

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

T E

T R

A T

E C

H

IN

C

W a rr in g to n W a y

L o u is v ill e

K Y

P h o n e

-5 w w w .t e tr a te c h .c o m

M e d lo ck B ri d g e

R D

S T

E

Jo h n s

C re ek

G A

P h on e (4

-6

FA-501

D e ta ils

D O

B B

IN

S

A

IR

R E

V E

R V

E B

A S

E G

A

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J R

P

L A

C E

L O

U

IS

V

IL

L E

K

Y

R H

E S

P R

IC

H

B K

O T

U L A

R H

E S

P R

IC

H

/1

/2

F Y

C E

R T

IF

IE

D F

IN

A

L

F G

W B

-0

S

E C

U R

IT

Y

F O

R C

E S

F A

C

IL

IT

Y

P R

O J E

C T

P

F ir e A la rm

SCALE: NTS

OPERATIONAL MATRIX

SCALE: NTS

FIRE ALARM AND MASS NOTIFICATION

TRANSCEIVER ANTENNA DETAIL

SCALE: NTS

FIRE ALARM AND MASS NOTIFICATION

RISER

A

M E

N D

M E

N T

/2 /2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns -0

SF30
SUMMARY OF CHANGES
Sheets
FA-002 - General Notes
FA-501 - Details

File details come from the government source that posted it. Updated .