W912QR24R0071_Plans-0001.pdf
PDF 2 MB Posted
- Attached to
- D/B/B CONSTRUCTION: W912QR24R0071 SECURITY FORCES TRAINING FACILITY, DOBBINS AIR RESERVE BASE, GA
- Solicitation number
- W912QR24R0071
About this file
This document is an amendment to a solicitation (W912QR24R0071) for the design-bid-build construction of a Security Forces Training Facility at Dobbins Air Reserve Base in Marietta, Georgia.
The amendment modifies the original solicitation by adding several attachments, including as-built drawings, a basis of design, and an FF&E package. It also replaces two specific plan sheets and extends the proposal response date to September 6, 2024. The overall project involves constructing a 21,464 SF facility with training, administrative, and storage spaces, to be designed as permanent construction in accordance with DoD Unified Facilities Criteria. This is a total small business set-aside with a Firm-Fixed-Price contract, and the NAICS code is 236220 - Commercial and Institutional Building Construction. The Government intends to award without discussions but reserves the right to conduct discussions. The magnitude of the construction project is anticipated to be between $10-25 million.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
Solicitation No. W912QR24R0071 for the Design-Bid-Build Construction of the Security Forces Training Facility at Dobbins ARB in Marietta, GA is hereby modified as follow s:
1. CONTRACT ID CODE PAGE OF PAGES
1 2
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W912QR24R0071
X 9B. DATED (SEE ITEM 11)
01-Aug-2024
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO.
5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
27-Aug-2024
CODE
U. S. ARMY ENGINEER DISTRICT, LOUISVILLE
600 DR. MARTIN LUTHER KING, JR. PLACE
ROOM 821
LOUISVILLE KY 40202-2239
W912QR 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W912QR24R0071_Plans-0001
W912QR24R0071
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE (SF 30)
The following have been modified:
AMENDMENT 0001
SUMMARY OF CHANGES
1. The following ATTACHMENTS have been added in their entirety for reference only:
Building 701 As-Builts Basis of Design Furniture, Fixtures, & Equipment (FF&E) Package
2. The following PLAN SHEETS have been replaced in their entirety:
FA-002 GENERAL NOTES FIRE ALARM
FA-501 DETAILS FIRE ALARM
3. The PROPOSAL RESPONSE DATE has been extended to:
06 SEPTEMBER 2024, 1:00 PM EDT
(End of Summary of Changes)
FIRE ALARM MASS NOTIFICATION NOTES:
1. THESE DOCUMENTS DEPICT AN ENGINEERING DESIGN LAYOUT TO BE UTILIZED
AS GUIDANCE FOR THE PLANNING OF THE FIRE ALARM/MASS NOTIFICATION
SYSTEM BY THE CONTRACTOR. LAYOUT IS GENERIC AND NOT MANUFACTURER
SPECIFIC. HOWEVER, SYSTEM, FMCP AND TRANSCEIVER MUST BE MONACO.
SCHEMATIC DRAWING MAY BE INCOMPLETE WITH SOME DEVICES NOT SHOWN
OR SEVERAL DEVICES REPRESENTING MORE. PROVIDE COMPLETE
DOCUMENTS FOR REVIEW AND APPROVAL FROM THE COR PRIOR TO
INSTALLATION. PROVIDE A COMPLETE INSTALLATION. PROVIDE DEVICES NOT
SHOWN FOR A COMPLETE FUNCTIONAL SYSTEM LIMITED TO ADDRESSABLE
MONITOR MODULES FOR ALL DEVICES THAT DO NOT HAVE ADDRESS AND
CONTROL MODULES TO CONTROL AUXILIARY FUNCTIONS. PROVIDE A
COMPLETE COMBINATION FIRE ALARM AND MASS NOTIFICATION SYSTEM, AND
INSTALLED IN ACCORDANCE WITH NFPA 72-2022, UFC 3-600-01, UFC 4-021-01,
ADA/ABA AND PROJECT SPECIFICATIONS.
2. PROVIDE AN INTELLIGENT, ADDRESSABLE COMBINATION FIRE ALARM/MASS
NOTIFICATION CONTROL PANEL (FMCP). THE FMCP MUST BE DESIGNED FOR
ACTIVATION OF FIRE ALARM NOTIFICATION, COMMON SIGNALS, ADDRESS
ANNUNCIATION, AND TRANSMISSION TO TRANSCEIVER.
3. PROVIDE BACKBOX AT EACH SPEAKER, STROBE, AND SPEAKER/STROBE
LOCATION.
4. CONTRACTOR SHALL PROVIDE METHOD FOR OVERRIDE OF ALARM FUNCTIONS
DURING PAGING.
5. PROVIDE ADDITIONAL MASS NOTIFICATION OR FIRE ALARM SPEAKERS AS
NECESSARY TO MEET THE AUDIBILITY REQUIREMENTS OF NFPA 72 AND TO
ENSURE THAT A COMMON INTELLIGIBILITY SCALE (CIS) SCORE OF 0.8 IS
PROVIDED IN EACH NORMALLY OCCUPIED AREA OF THE BUILDING.
6. MOUNT ALL WALL-MOUNTED NOTIFICATION APPLIANCES WITH THE BOTTOM OF
THE STROBE LENS AT 80" AFF, OR 6" BELOW THE CEILING (WHICHEVER IS
LOWER) UNO.
7. PROVIDE TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) ON ALL FIRE
ALARM AND MASS NOTIFICATION SYSTEM CIRCUITS ENTERING OR LEAVING THE
FACILITY. ROUTE UNDERGROUND CIRCUITS AND CONDUIT PER NEC ARTICLE
800.
8. MOUNTING OF DEVICES MUST COMPLY WITH NFPA AND ABA/ADA
REQUIREMENTS UNO MOUNT THE OPERABLE PART OF MANUAL PULL, AT 44"
AFF.
9. PROVIDE CLASS B SIGNALING LINE CIRCUITS, CLASS B INITIATING DEVICE
CIRCUITS, AND CLASS B NOTIFICATION APPLIANCE CIRCUITS FOR THE MASS
NOTIFICATION SYSTEMS.
10. PROVIDE NOTIFICATION APPLIANCES FOR FA/MNS SYSTEM WITH WHITE
FACEPLATES AND CLEAR STROBES MARKED WITH "ALERT" IN THE COLOR RED
THROUGHOUT FINISHED AREAS OF THE BUILDING.
11. REFERENCE ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATED
PLACEMENT OF APPLIANCES WITH LOCATIONS OF DIFFUSERS, LIGHTS, AND
OTHER DEVICES.
12. DEVICES ARE DESIGNED TO BE INSTALLED ON BOTH WALLS AND CEILINGS.
COORDINATE ALL WORK PRIOR TO INSTALLATION WITH ALL OTHER TRADES.
13. ALL FIRE ALARM/MASS NOTIFICATION CONTROL PANELS AND UNITS MUST BE
PROVIDED IN YEAR ROUND CONDITIONED SPACES. ALL FIRE ALARM AND MASS
NOTIFICATION CONTROL PANELS SHALL BE INSTALLED A MAXIMUM OF 5 FEET
ABOVE FINISHED FLOOR MEASURED TO CENTERLINE OF THE PANEL.
14. THE MNS MUST BE EQUIPPED FOR BUILDING PAGING.
15. SECONDARY POWER SUPPLY MUST BE SIZED TO PROVIDE THE GREATER OF 48
HOURS OF STANDBY TIME, AN ADDITIONAL 15 MINUTES OF ALARM/FULL LOAD
TIME FOR FIRE ALARM SYSTEM AND 60 MINUTES OF NOTIFICATION ON THE MNS.
16. POWER CIRCUITS FOR FIRE ALARM CONTROL PANEL AND FIRE ALARM SYSTEM
POWER MUST BE ON A DEDICATED 120V AND SHALL HAVE A RED MARKING,
LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT".
17. PROVIDE ADDRESSABLE DOUBLE ACTION PULL STATIONS AT EACH EXIT DOOR,
INCLUDING MECHANICAL ROOMS, ELECTRIC ROOMS, AND OTHER ROOMS AS
SHOWN ON DRAWINGS. MANUAL PULL STATIONS SHALL NOT NEED GLASS
RODS.
18. SEAL ALL PENETRATIONS THROUGH FIRE RATED PARTITIONS OR BARRIERS
WITH UL LISTED THROUGH PENETRATION FIRE STOP SYSTEM, PROVIDING A
FIRE RATING EQUAL OR GREATER THAN THE FIRE RATED BARRIER.
19. ALL FIRE ALARM AND MASS NOTIFICATION SYSTEM WIRING MUST BE SOLID
COPPER (UNO). ALL FIRE ALARM CIRCUITS MUST BE PULLED SPLICE FREE,
WHERE CONNECTIONS ARE UNAVOIDABLE CONNECTIONS MUST BE MADE WITH
THERMALLY INSULTED SCREW TYPE TERMINAL STRIPS.
20. DUCT DETECTORS (IF INSTALLED) MUST BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS FOR STRAIGHT DUCT LENGTHS, ALL
SAMPLING TUBES SHALL COVER THE ENTIRE WIDTH OF THE DUCT ASSEMBLIES.
21. VISUAL DEVICES ARE REQUIRED IN ALL PUBLIC USE AREAS, COMMON USE
AREAS AND EMPLOYEE WORK AREAS TO INCLUDE OFFICE SUITES AND AREAS
INTENDED TO HAVE MORE THAN ONE DESK/ OCCUPANT.
22. FIRE ALARM CONTROL PANEL WILL REQUIRE 4FT OF WALL SPACE.
23. ALL NEW CONDUIT IS TO BE FACTORY PAINTED RED.
24. THE CONTRACTOR MUST PAINT ALL NEW CONVER PLATES FOR THE FIRE
ALARM CONDUIT JUNCTION BOXES RED. THE COVERS MUST BE PROPERLY
CLEANED PRIOR TO PAINTING. PROVIDE TWO COATS OF FACTORY APPLIED
ENAMEL PAINT.
25. THIS BUILDING IS CLASSIFIED AS A C2 BUILDING. THE BUILDING WILL BE
PROVIDED WITH SMALL VOICE INSIDE THE BUILDING FROM THE GIANT VOICE
NETWORK.
26. SYSTEM, FMCP AND TRANSCEIVER SHALL BE MONACO.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T E
T R
A T
E C
H
IN
C
W a rr in g to n W a y
L o u is v ill e
K Y
P h o n e
-5 w w w .t e tr a te c h .c o m
M e d lo ck B ri d g e
R D
S T
E
Jo h n s
C re ek
G A
P h on e (4
-6
FA-002
G e n e ra l N o te s
D O
B B
IN
S
A
IR
R E
V E
R V
E B
A S
E G
A
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G J R
P
L A
C E
L O
U
IS
V
IL
L E
K
Y
R H
E S
P R
IC
H
B K
O T
U L A
R H
E S
P R
IC
H
/1
/2
F Y
C E
R T
IF
IE
D F
IN
A
L
F G
W B
-0
S
E C
U R
IT
Y
F O
R C
E S
F A
C
IL
IT
Y
P R
O J E
C T
P
F ir e A la rm
STANDARD FIRE ALARM/MASS NOTIFICATION MESSAGES
No. Activation Name Tone Type Tone Cycles Tone Duration Message Content LED Text Sign Message Loop Duration (UFC
4-021-01)
1 Building Emergency (Evacuate)
Chime (NFPA 72, Figure A.18.4.2.1(b))
2 times before and after message (NFPA 72, 24.4.2.1)
Per NFPA 72, Figure A.18.4.2.1(b)
"May I have your attention please. An emergency has been reported in the building.
Please walk to the nearest exit and leave the building."
Display "Evacuate" and voice message
Continuous, for 10 minutes if overriding fire alarm
2 Area Emergency (Shelter-In-Place)
Chime or 1000 Hz tone 2 times before the message only
3 seconds "May I have your attention please. An emergency has been reported in the area.
Please remain in the building and await further instructions."
Display "Announcement" and voice message
Continuous, for 10 minutes if overriding fire alarm
3 Area Emergency (ATFP Initiatives)
Chime or 1000 Hz tone 2 times before the message only
3 seconds "May I have your attention please. An emergency has been reported in the area. Close doors and windows. Shut off all heating, ventilation, and air conditioning. Seek shelter immediately."
Display "Announcement" and voice message
Continuous, for 10 minutes if overriding fire alarm
4 Severe Thunderstorm Warning
Chime or 1000 Hz tone 2 times before the message only
3 seconds "May I have your attention please. The National Weather Service has issued a SEVERE THUNDERSTORM WARNING for this area; please take immediate shelter indoors."
Display "Announcement" and voice message
Continuous, for 10 minutes if overriding fire alarm
5 Tornado Warning Chime or 1000 Hz tone 2 times before the message only
3 seconds "May I have your attention please. The National Weather Service has issued a TORNADO WARNING for this area; please take immediate shelter in the tornado shelter, basement, or on the lowest level at the center of the building away from exterior windows and doors."
Display "Announcement" and voice message
Continuous, for 10 minutes if overriding fire alarm
6* Fire Alarm (Automatic and Pre-recorded)
Three Pulse Temporal
(NFPA 72, 18.4.2.1)
2 times before and after message (NFPA 72, 24.4.2.1)
Per NFPA 72, Figure 18.4.2.1
"May I have your attention please. An emergency has been reported in the building.
Please walk to the nearest exit and leave the building."
Display "Evacuate" and voice message
Continuous (UFGS 28 31 76)
7 Test Chime or 1000 Hz tone 2 times before and after the message
3 seconds "May I have your attention please. This is a test of the building mass notification system.
Please continue your normal duties. This is only a test."
Display "Announcement" and voice message
Once
8 All Clear Chime or 1000 Hz tone 2 times before and after the message
3 seconds "May I have your attention please. An all clear has been issued, resume normal activities."
Display "Announcement" and voice message
Once
9 Carbon Monoxide Four pulse temporal pattern
2 times before and after the message
3 seconds "May I have your attention please. Carbon Monoxide has been reported in the building.
Please walk to the nearest exit and leave the building."
Display "Evacuate" and voice message
Continuous
10 MNS Microphone (LOC or ACU Keying)
Chime or 1000 Hz tone Once Display "Announcement" and voice message
11 Public Address Microphone
Chime/tone distinctive from MNS/FA messages
Once N/A N/A
Notes:
1. All references to NFPA 72 contained herein are to the 2022 edition.
2. The tones and message content may vary depending upon occupancy type. (i.e. Child Development Centers).
3. All pre-recorded and automatic messages shall utilize a female voice.
4. Modify the evacuation messages for multi-story buildings to restrict the use of elevators, where applicable.
5. Blanks may be used for specific messages that are Base specific, region specific, hazard specific Force Protection conditions, hostile intruder, bomb threat, etc.
6. Sever Thunderstorm and Tornado Warnings shall be modified for region specific weather events.
7. Use a single tone type for all pre-recorded non-fire alarm, non-weather messages unless installation specific criteria exist.
8. LED text signs shall display the word "Evacuate" or Announcement" followed by the content of the pre-recorded or automatic message being played. For live announcements, the LED text sign shall read "Announcement" only.
9. LED text signs shall display the message content by scrolling on the message board bottom to top or right to left. "Announcement" and Evacuate" text may be static or flashing.
*Fire alarm message shall be the lowest priority of the emergency messages according to NFPA 72. Activation of all other MNS emergency messages shall override the fire alarm message.
A
M E
N D
M E
N T
/2 /2
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns -0
SHUT
DOW
N R
ESPECTI
VE A
IR
H
ANDLIN
G E
QUIP
M
ENT
REQUIRED FIRE SAFETY CONTROL
ACTU
ATE
A
UDIB
LE
S
UPERVIS
ORY S
IG
NAL
ACTU
ATE
C
OMMON S
UPERVIS
ORY S
IG
NAL I
NDIC
ATO
R
ACTU
ATE
A
UDIB
LE
A
LA
RM S
IG
NAL
ACTU
ATE
C
OMMON A
LA
RM S
IG
NAL I
NDIC
ATO
R
FIRE ALARM SYSTEM LOW BATTERY
AREA SMOKE DETECTORS
CONTROL COMPONENT TROUBLE CONDITION
BUILDING MANUAL PULL STATIONS
MAIN SPRINKLER FLOW SWITCH
CIRCUIT FAULT - FACP
CIRCUIT FAULT - MNS
SPRINKLER TAMPER SWITCH
FIRE ALARM SYSTEM
INPUT/OUTPUT MATRIX
SYSTEM INPUTS
FIRE ALARM SYSTEM AC POWER FAILURE
FACP ANNUNCIATION
ACTU
ATE
Z
ONE O
R D
EVIC
E A
DDRESS A
LA
RM IN
DIC
ATO
R
TRANSMIT
T
ROUBLE
S
IG
NAL T
O C
ENTRAL S
TATIO
N
TRANSMIT
S
UPERVIS
ORY S
IG
NAL
TO C
ENTR
AL S
TA
TIO
N
TRANSMIT
F
IR
E A
LA
RM S
IG
NAL T
O C
ENTRAL S
TATI
ON
ACTU
ATE
A
UDIB
LE
T
ROUBLE
S
IG
NAL
ACTU
ATE
C
OMMON T
ROUBLE
S
IG
NAL I
NDIC
ATOR
SYSTEM OUTPUTS
NOTIFICATION
B CA HGFED LK MI J RQPON T US WV
ACTIVATION OF LOC
MNS MESSAGE SWITCH AT FMCP
ALARM SILENCING SWITCH
SUPERVISORY/TROUBLE SILENCING SWITCH
SILE
NCE A
UDIO
/V
IS
UAL T
ROUBLE
S
IG
NAL
SEE S
PEC
SECTI
ON 28
F
OR A
DDIT
IO
NAL R
EQUIR
EMENTS
SILE
NCE A
UDIO
/V
IS
UAL N
OTI
FIC
ATI
ON. N
OTI
FIC
ATIO
N T
O
RESTA
RT U
PON S
UBSEQUENT
ALA
RM
SHUTD
OW
N A
LL
F
IR
E A
LA
RM N
OTIF
IC
ATI
ON
ACTI
VATE
R
ECORDED M
NS M
ESSAGE
HVAC AIR DUCT SMOKE DETECTORS
CARBON MONOXIDE DETECTOR
FLOW SWITCH IN SERVER ROOM
SHUT
DOW
N S
ERVER R
OOM
TRANSMIT
M
NS O
VERID
E T O C
ENTRAL S
TATIO
N
TRANSMIT
C
ARBON M
ONOXID
E S
IG
NAL T
O C
ENTR
AL
STA
TIO
N
ACTI
VATE
C
ARBON M
ONOXID
E A
LA
RM
ACTI
VATE
V
IS
UAL N
OTIF
IC
ATON/S
TR
OBES
ACTI
VATE
W
ATER F
LO
W
B
ELL
ACTI
VATE
E
GRESS LI
GHTIN
G
SHUT
DOW
N B
ATT
ERY C
HARGER
X
B CA HGFED LK MI J RQPON T US WV X
FLOW SWITCH IN ELECTRICAL ROOM
Y Z AA
ACTI
VATE S
CROLL
IN
G LE
D T
EXT S
IG
NAGE -
EVACUATI
ON
ACTI
VATE
S
CROLL
IN
G LE
D T
EXT S
IG
NAGE -
ANNOUNCEMENT
Y Z AA
DETAIL NOTES:
1. PROVIDE BUILDING TRANSCEIVER (MONACO)
2. PROVIDE A OMNIDIRECTIONAL ANTENNA
THE ANTENNA MUST BE SET TO BASE FREQUENCY.
4. ANTENNA CABLE MUST BE IN RIGID OR EMT RACEWAY.
5. ANTENNA MUST BE PLACED IN CLEAR LINE OF SIGHT WITH SUPERVISING
STATION. COORDINATE LOCATION WITH THE COR.
TRANSCEIVER ANTENNA
1-INCH EMT CONDUIT TO BUILDING GROUND
ENCLOSURE W/
CONNECTION
TO GROUND
1-INCH EMT CONDUIT WITH
ANTENNA CABLE WIRE TO J-BOX.
1 INCH CONDUIT WITH
ANTENNA CABLE
ANTENNA, ATTACH TO 1 INCH
RGS CONDUIT WITH GALVANIZED
OR STAINLESS STEEL STRAPS
STRUCTURAL BRACE (TYP)
PIPE CLAMP (TYP)
PENETRATE WALL WITH 1-1/2 INCH
CONDUIT SLEEVE.
TO TRANSCEIVER
AUD/FA AUD NAC 2
AUD/MNS NAC 1
FIRE ALARM CONTROL
PANEL FMCP (MONACO)
FIRE ALARM RADIO
TRANSCEIVER
RT (MONACO)
BATT
AND MASS COMMUNICATIONS
AUD/MNS NAC 4
AUD/MNS NAC 3
WP
WP
WP
SA
SA
SIGNALING LINE CIRCUIT
SLC
EOL
AUD/MNS NAC 5
WP
WP
NOT ALL DEVICES
ARE SHOWN FOR
CLARITY
TEXTTEXT TEXT
R
CM
CM
MM
MM
MM
F
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
MM
MM
T MM
CONDUCTOR
TO ECC
T
T
T
F
F
S
CO
F
F MM
T MM
120 v
120 v
MM
ANN
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
T E
T R
A T
E C
H
IN
C
W a rr in g to n W a y
L o u is v ill e
K Y
P h o n e
-5 w w w .t e tr a te c h .c o m
M e d lo ck B ri d g e
R D
S T
E
Jo h n s
C re ek
G A
P h on e (4
-6
FA-501
D e ta ils
D O
B B
IN
S
A
IR
R E
V E
R V
E B
A S
E G
A
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G J R
P
L A
C E
L O
U
IS
V
IL
L E
K
Y
R H
E S
P R
IC
H
B K
O T
U L A
R H
E S
P R
IC
H
/1
/2
F Y
C E
R T
IF
IE
D F
IN
A
L
F G
W B
-0
S
E C
U R
IT
Y
F O
R C
E S
F A
C
IL
IT
Y
P R
O J E
C T
P
F ir e A la rm
SCALE: NTS
OPERATIONAL MATRIX
SCALE: NTS
FIRE ALARM AND MASS NOTIFICATION
TRANSCEIVER ANTENNA DETAIL
SCALE: NTS
FIRE ALARM AND MASS NOTIFICATION
RISER
A
M E
N D
M E
N T
/2 /2
ARIMS: 200A Disposition: Maintain for 15 yrs after construction
W
2Q R
R
_P la ns -0
| SF30 |
| SUMMARY OF CHANGES |
| Sheets |
| FA-002 - General Notes |
| FA-501 - Details |
File details come from the government source that posted it. Updated .