W912QR24R0009_Plans_Vol5-0000.pdf

PDF 5 MB Posted

Attached to
Solicitation W912QR24R0009 USARC Ft. Buchanan Puerto Rico
Solicitation number
W912QR24R0009
Issued by

About this file

This set of construction plans outlines the mechanical, electrical, and plumbing systems for a new U.S. Army Reserve Center in Puerto Rico. The project involves renovating existing facilities and constructing new buildings. Key specifications include air handling units, dedicated outdoor air systems, air distribution devices, terminal units, variable air volume controls, and chilled water systems. Piping diagrams provide details on refrigerant, chilled water, and condensate routing. Schedules list equipment capacities and electrical requirements. The plans appear to be the certified final submittal for solicitation number W912QR24R0009 issued by the U.S. Army Corps of Engineers Engineering District Louisville.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers®

SHEET ID

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

PROJECT NO. 89301, P2# 481867

PR

O

JE

C

T N

O . 8

, P 2#

N

L

J

G

E

C

A

P

M

K

H

F

D

B

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

LOUISVILLE DISTRICT

ISSUE DATE: OCTOBER 27, 2023

CONTRACT NO.: -

SOLICITATION NO.: -

CERTIFIED FINAL SUBMITTAL

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

G-001

C O

VE

R

S H

EE

T

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

LO

U

IS

VI

LL

E D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

M .B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, D .H

EN

SL

EY

FORT BUCHANAN, PUERTO RICO

U.S. ARMY RESERVE CENTER OPERATIONS BUILDING

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

K

ER D

.A

M N

B

A M

M

10/27/2023

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/202310/27/2023

10/27/2023

10/27/2023

10/27/2023

10/27/23

VOLUME 5 OF 6

W

2Q R

R

_P la ns _V ol 5-

22 November 2023

W912QR24R0009

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

SHEET ID

P R

O J E

C T

N O

P

C E

R T

IF

IE

D F

IN

A

L S

U B

M

IT

T A

L

D R

A W

IN

G

L

IS

T

U .S

A

R M

Y R

E S

E R

V E

C E

N T

E R

O P

E R

A T

IO

N

S B

U

IL

D

IN

G

F O

R T

B U

C H

A N

A N

P

U E

R T

O R

IC

O

M B

A R

N E

T T

K R

IG

G

S

A M

C C

O Y

O C

T O

B E

R

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

G-002

D H

E N

S L E

Y

SHEET LIST

SHEET NUMBER SHEET NAME

M-713 MECHANICAL CONTROLS

ELECTRICAL

E-001 ELECTRICAL LEGEND

E-002 ELECTRICAL GENERAL NOTES & ABBREVIATIONS

EL111 PARTIAL LIGHTING PLAN

EL112 PARTIAL LIGHTING PLAN

EL113 PARTIAL LIGHTING PLAN

EL601 LIGHTING DIAGRAMS

EL701 LIGHTING SCHEDULES

EP111 PARTIAL POWER PLAN

EP112 PARTIAL POWER PLAN

EP113 PARTIAL POWER PLAN

EP130 BID OPTION 0014 - ROOF PV ARRAY PLAN

EP151 PARTIAL HVAC POWER PLAN

EP152 PARTIAL HVAC POWER PLAN

EP153 PARTIAL HVAC POWER PLAN

EP410 ENLARGED POWER PLANS

EP501 ELECTRICAL DETAILS

EP601 POWER ONE LINE DIAGRAM

EP701 PANEL SCHEDULES

EP702 PANEL SCHEDULES

EP703 PANEL SCHEDULES

EP704 PANEL SCHEDULES

EP705 PANEL SCHEDULES

EY111 PARTIAL SPECIAL SYSTEMS PLAN

EY112 PARTIAL SPECIAL SYSTEMS PLAN

EY113 PARTIAL SPECIAL SYSTEMS PLAN

EY501 SPECIAL SYSTEMS DETAILS

EG130 LIGHTNING PROTECTION PLAN

EG131 BID OPTION 0014 - LIGHTNING PROTECTION PLAN

EG501 LIGHTNING PROTECTION DETAILS

EG502 GROUNDING DETAILS

EG601 GROUNDING ONE LINE DIAGRAM

TELECOMMUNICATIONS

T-001 COMMUNICATIONS LEGENDS

T-002 COMMUNICATIONS GENERAL NOTES & ABBREVIATIONS

T-111 PARTIAL COMMUNICATIONS PLAN

T-112 PARTIAL COMMUNICATIONS PLAN

T-113 PARTIAL COMMUNICATIONS PLAN

T-410 ENLARGED COMMUNICATIONS PLANS

T-501 COMMUNICATIONS DETAILS

T-502 COMMUNICATIONS DETAILS

T-601 COMMUNICATION DIAGRAMS

T-602 COMMUNICATION ROOM 147 ELEVATION DIAGRAM

T-603 COMMUNICATION ROOM 126 ELEVATION DIAGRAM

SHEET LIST

SHEET NUMBER SHEET NAME

INTERIORS

I-001 FF&E LEGEND

I-110 COMPOSITE FURNITURE PLAN

I-111 PARTIAL FURNITURE PLAN

I-112 PARTIAL FURNITURE PLAN

I-113 PARTIAL FURNITURE PLAN

LIFE SAFETY

LS001 ABBREVIATIONS, LEGEND AND GENERAL NOTES

LS100 CODE COMPLIANCE SITE PLAN

LS110 LEVEL 1 LIFE SAFETY PLAN - COMPOSITE

FIRE PROTECTION

FP001 ABBREVIATIONS, LEGEND AND GENERAL NOTES

FP110 LEVEL 1 FIRE PROTECTION PLAN - COMPOSITE

FP501 FIRE PROTECTION DETAILS

FP502 FIRE PROTECTION DETAILS

FIRE ALARM

FA001 ABBREVIATIONS, LEGEND AND GENERAL NOTES

FA110 LEVEL 1 FIRE ALARM PLAN - COMPOSITE

FA501 FIRE ALARM DETAILS

FA502 FIRE ALARM DETAILS

PLUMBING

P-001 ABBREVIATIONS, LEGEND AND GENERAL NOTES

PP101 PARTIAL UNDERGROUND PLAN

PP102 PARTIAL UNDERGROUND PLAN

PP111 PARTIAL SANITARY PLAN

PP112 PARTIAL SANITARY PLAN

PP113 PARTIAL WATER PLAN

PP114 PARTIAL WATER PLAN

PP115 PARTIAL WATER PLAN

P-401 ENLARGED PLANS

P-402 ENLARGED PLANS

P-403 ENLARGED PLANS

P-404 ENLARGED PLANS

P-405 ENLARGED PLANS

P-406 ENLARGED PLANS

P-501 DETAILS

P-502 DETAILS

P-503 DETAILS

P-504 DETAILS

P-601 SCHEDULES

P-900 RISER DIAGRAMS

P-901 RISER DIAGRAMS

P-902 RISER DIAGRAMS

P-910 RISER DIAGRAMS

P-911 RISER DIAGRAMS

P-912 RISER DIAGRAMS

MECHANICAL

M-001 ABBREVIATIONS, LEGEND AND GENERAL NOTES

MH111 PARTIAL FLOOR PLAN - HVAC

MH112 PARTIAL FLOOR PLAN - HVAC

MH113 PARTIAL FLOOR PLAN - HVAC

MP111 PARTIAL FLOOR PLAN - PIPING

MP112 PARTIAL FLOOR PLAN - PIPING

MP113 PARTIAL FLOOR PLAN - PIPING

M-301 SECTIONS

M-411 ENLARGED PLAN - HVAC

M-412 ENLARGED PLAN - PIPING

M-501 MECHANICAL DETAILS

M-502 MECHANICAL DETAILS

M-503 MECHANICAL DETAILS

M-504 MECHANICAL DETAILS

M-505 MECHANICAL DETAILS

M-506 MECHANICAL DETAILS

M-507 MECHANICAL DETAILS

M-550 AIR RISER DIAGRAM

M-551 AIR RISER DIAGRAM

M-552 AIR RISER DIAGRAM

M-553 CHILLED WATER PIPING DIAGRAM

M-601 MECHANICAL SCHEDULES

M-602 MECHANICAL SCHEDULES

M-603 MECHANICAL SCHEDULES

M-701 MECHANICAL CONTROLS

M-702 MECHANICAL CONTROLS

M-703 MECHANICAL CONTROLS

M-704 MECHANICAL CONTROLS

M-705 MECHANICAL CONTROLS

M-706 MECHANICAL CONTROLS

M-707 MECHANICAL CONTROLS

M-708 MECHANICAL CONTROLS

M-709 MECHANICAL CONTROLS

M-710 MECHANICAL CONTROLS

M-711 MECHANICAL CONTROLS

M-712 MECHANICAL CONTROLS

SHEET LIST

SHEET NUMBER SHEET NAME

S-362 FRAMING SECTIONS

S-363 FRAMING SECTIONS

S-364 FRAMING SECTIONS

S-365 FRAMING SECTIONS

S-366 BID OPTION - SOLAR PANEL SUPPORT FRAMING SECTIONS

S-401 ENLARGED RAMP FOUNDATION/SLAB PLAN

S-402 RAMP SECTIONS

S-411 ENLARGED VAULT ROOF SLAB FRAMING PLAN

S-412 VAULT SECTIONS AND DETAILS

S-413 VAULT SECTIONS

S-501 TYPICAL FOUNDATION DETAILS

S-502 TYPICAL FOUNDATION DETAILS

S-503 PRECAST WALL PANEL DETAILS

S-511 TYPICAL FRAMING DETAILS

S-601 SCHEDULES

S-602 SPECIAL JOIST LOADING DIAGRAM

ARCHITECTURE

A-001 SYMBOL LEGEND

A-110 COMPOSITE FLOOR PLAN

A-111D PARTIAL DIMENSION PLAN

A-111N PARTIAL NOTE PLAN

A-112D PARTIAL DIMENSION PLAN

A-112N PARTIAL NOTE PLAN

A-113D PARTIAL DIMENSION PLAN

A-113N PARTIAL NOTE PLAN

A-130 COMPOSITE ROOF PLAN

A-140 COMPOSITE REFLECTED CEILING PLAN

A-141 PARTIAL REFLECTED CEILING PLAN

A-142 PARTIAL REFLECTED CEILING PLAN

A-143 PARTIAL REFLECTED CEILING PLAN

A-160 COMPOSITE PRECAST PANEL FLOOR PLAN

A-161 PRECAST PANEL ELEVATIONS

A-162 PRECAST PANEL DETAILS

A-181 PARTIAL SIGNAGE PLAN

A-182 PARTIAL SIGNAGE PLAN

A-183 PARTIAL SIGNAGE PLAN

A-200 COMPOSITE BUILDING ELEVATIONS

A-201 ENLARGED BUILDING ELEVATIONS

A-202 ENLARGED BUILDING ELEVATIONS

A-203 ENLARGED BUILDING ELEVATIONS

A-204 ENLARGED BUILDING ELEVATIONS

A-301 BUILDING SECTIONS

A-310 WALL SECTIONS

A-311 WALL SECTIONS

A-400 ENLARGED RESTROOM PLAN

A-401 RESTROOM DETAILS

A-402 TYPICAL RESTROOM MOUNTING HEIGHTS

A-410 RESTROOM ELEVATIONS

A-450 RAILING DETAILS

A-461 PARTIAL FINISH PLAN

A-462 PARTIAL FINISH PLAN

A-463 PARTIAL FINISH PLAN

A-500 DOOR AND FRAME TYPES AND ABA MANEUVERING

CLEARANCES

A-501 DOOR DETAILS

A-502 DOOR DETAILS

A-510 WINDOW TYPES & DETAILS

A-530 LOUVER TYPES AND DETAILS

A-540 WALL TYPES

A-541 WALL DETAILS

A-542 WALL DETAILS

A-550 COLUMN DETAILS

A-551 COLUMN DETAILS

A-560 CEILING DETAILS

A-570 ROOF DETAILS

A-571 ROOF DETAILS

A-580 MISCELLANEOUS DETAILS

A-600 DOOR SCHEDULE

A-610 FINISH SCHEDULE AND EXTERIOR FINISH KEY

A-611 FINISH KEYS & NOTES

A-620 SIGNAGE SCHEDULE

A-621 SIGNAGE DETAILS

A-700 ENLARGED VAULT DIMENSION PLAN

A-701 ENLARGED VAULT NOTED PLAN

A-710 ENLARGED CAGE PLANS

A-711 CAGE ELEVATIONS

A-712 CAGE SECTIONS AND DETAILS

A-713 CAGE DETAILS

A-800 ENLARGED KITCHEN PLAN

A-801 KITCHEN SCHEDULE

A-900 AIR BARRIER FLOOR PLAN

A-901 AIR BARRIER WALL SECTION

SHEET LIST

SHEET NUMBER SHEET NAME

GENERAL

G-001 COVER SHEET

G-002 DRAWING LIST

G-201 LOCATION AND VICINITY MAP

G-202 PROJECT AERIAL

CIVIL

V-101 OVERALL SITE SURVEY

V-111 SITE SURVEY

V-112 SITE SURVEY

B-101 OVERALL BORING PLAN

B-111 BORING PLAN

B-112 BORING PLAN

B-201 BORING LOGS

B-202 BORING LOGS

C-001 CIVIL LEGEND AND ABBREVATIONS

C-002 CIVIL GENERAL NOTES

CD101 OVERALL DEMOLITION PLAN

CD111 DEMOLITION PLAN

CD112 DEMOLITION PLAN

CG101 OVERALL GRADING AND DRAINAGE PLAN

CG111 GRADING AND DRAINAGE PLAN

CG112 GRADING AND DRAINAGE PLAN

CG201 STORM SEWER PROFILES & SCHEDULE

CG501 DRAINAGE DETAILS

CG502 DRAINAGE DETAILS

CG503 DRAINAGE DETAILS

CG701 OVERALL SEDIMENT AND EROSION CONTROL PLAN

CG711 SEDIMENT AND EROSION CONTROL PLAN

CG712 SEDIMENT AND EROSION CONTROL PLAN

CG801 SEDIMENT AND EROSION CONTROL NOTES

CG802 SEDIMENT AND EROSION CONTROL DETAILS

CG803 SEDIMENT AND EROSION CONTROL DETAILS

CG804 SEDIMENT AND EROSION CONTROL DETAILS

CG805 SEDIMENT AND EROSION CONTROL DETAILS

CG806 SEDIMENT AND EROSION CONTROL DETAILS

CS101 OVERALL SITE LAYOUT

CS111 SITE LAYOUT

CS112 SITE LAYOUT

CS401 JOINT LAYOUT PLAN

CS501 PAVEMENT DETAILS

CS502 PAVEMENT DETAILS

CS503 DESIGNATED SMOKING AREA SIGNAGE

CU101 OVERALL UTILITY PLAN

CU111 UTILITY PLAN

CU112 UTILITY PLAN

CU201 SANITARY SEWER PROFILES & SCHEDULE

CU501 SANITARY SEWER DETAILS

CU502 SANITARY SEWER DETAILS

CU511 WATER DETAILS

CU512 WATER DETAILS

LP101 OVERALL LANDSCAPE PLAN

LP111 LANDSCAPE PLAN

LP112 LANDSCAPE PLAN

ELECTRICAL

ES100 EXISTING ELECTRICAL SITE PLAN

ES101 ELECTRICAL SITE PLAN

ES501 SITE ELECTRICAL DETAILS

ES502 BID OPTION - SITE ELECTRICAL DETAILS

ES503 SITE ELECTRICAL DETAILS

TELECOMMUNICATIONS

TS101 COMMUNICATION SITE PLAN

STRUCTURAL

S-001 GENERAL STRUCTURAL NOTES AND DESIGN CRITERIA

S-002 GENERAL STRUCTURAL NOTES, DESIGN CRITERIA AND

ABBREVIATIONS

S-003 COMPONENTS AND CLADDING WIND LOAD DIAGRAM

S-111 PARTIAL FOUNDATION/FLOOR SLAB PLAN

S-112 PARTIAL FOUNDATION/FLOOR SLAB PLAN

S-113 PARTIAL FOUNDATION/FLOOR SLAB PLAN

S-114 SLAB ON GRADE CONTROL JOINT PLAN

S-131 PARTIAL ROOF FRAMING PLAN

S-132 PARTIAL ROOF FRAMING PLAN

S-133 PARTIAL ROOF FRAMING PLAN

S-141 BID OPTION - SOLAR PANEL SUPPORT FRAMING PLAN

S-200 PRECAST CONCRETE WALL ELEVATIONS KEY PLAN

S-211 CONCRETE WALL ELEVATIONS

S-212 CONCRETE WALL ELEVATIONS

S-213 CONCRETE WALL ELEVATIONS

S-251 OPERABLE PARTITION SUPPORT FRAMING ELEVATION AND

SECTION

S-301 FOUNDATION SECTIONS

S-302 FOUNDATION SECTIONS

S-361 FRAMING SECTIONS

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

K

ER D

.A

M N

B

A M

M

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

W

2Q R

R

_P la ns _V ol 5-

SUPPLY AIR, ELBOW DOWN

RETURN OR OUTSIDE AIR, ELBOW DOWN

EXHAUST OR RELIEF AIR, ELBOW DOWN

SUPPLY AIR, ELBOW UP

RETURN OR OUTSIDE AIR, ELBOW UP

EXHAUST OR RELIEF AIR, ELBOW UP

ROUND DUCT OFFSET UP

RECTANGULAR DUCT OFFSET UP

DUCT SECTION, RECTANGULAR SUPPLY AIR

DUCT SECTION, RECTANGULAR RETURN

AIR OR OUTSIDE AIR

DUCT SECTION, RECTANGULAR EXHAUST

AIR OR RELIEF AIR

DUCT SECTION, ROUND SUPPLY AIR

DUCT SECTION, ROUND RETURN AIR OR

OUTSIDE AIR

DUCT SECTION, ROUND EXHAUST AIR OR

RELIEF AIR

45° BEVELED ENTRY TAP

45° BEVELED TAP, SQUARE TO ROUND

DUCT TRANSITION, SQUARE TO

SQUARE

DUCT TRANSITION, SQUARE TO

ROUND

MITERED ELBOW WITH TURNING VANES

BELLMOUTH OPENING (45° ENTRY)

SIDEWALL GRILLE

CEILING DIFFUSER, SUPPLY

CEILING GRILLE, RETURN OR EXHAUST

SQUARE AIR TERMINAL DEVICE TYPE & AIR

FLOW CFM; REFER TO AIR DISTRIBUTION

DEVICE SCHEDULE

S1A

RECTANGULAR AIR TERMINAL DEVICE

TYPE SIZE IN INCHES & AIR FLOW CFM;

REFER TO AIR DISTRIBUTION DEVICE

SCHEDULE

12x12

S8A

PIPE SECTION

PIPE ELBOW DOWN, DOUBLE LINE

PIPE ELBOW UP, DOUBLE LINE

PIPE OFFSET UP

DIRECTION OF FLOW IN PIPE

DIRECTION OF SLOPE DOWN IN PIPE

CLEANOUT

MOTORIZED DAMPER

SMOKE DAMPER AND ACCESS DOOR

FIRE DAMPER AND ACCESS DOOR

COMBINATION FIRE AND SMOKE

DAMPER

S

VOLUME BALANCING DAMPER

THERMOSTAT

CARBON DIOXIDE SPACE SENSORCO2

DOOR UNDERCUT

SUPPLY AIR FLOW DIRECTION

RETURN/EXHAUST AIR FLOW DIRECTION

H HUMIDISTAT

CO2 CARBON DIOXIDE SENSOR

SP STATIC PRESSURE TRANSMITTER

RECTANGULAR DUCT SIZE IN INCHES

ROUND DUCT SIZE IN INCHES

12x12

12Ø

OCCUPANCY SENSOROS

T

FLEXIBLE PIPE CONNECTION

AUTOMATIC FLOW DEVICE

PRESSURE GAUGE

THERMOMETER

THERMOMETER WELL

TEMPERATURE/PRESSURE TEST PORT

PIPE CAP

PUMP

GATE VALVE

GLOBE VALVE

BALL VALVE

BUTTERFLY VALVE

BALANCING COCK

AUTOMATIC 2-WAY CONTROL VALVE

AUTOMATIC 3-WAY CONTROL VALVE

PRESSURE REDUCING VALVE

PRESSURE RELIEF VALVE

S

M

LIFT CHECK VALVE

E EMERGENCY HVAC SHUTOFF SWITCH

DS DUCT SMOKE DETECTOR

SW SPACE MOUNTED SWITCH

KITCHEN GAS SHUTDOWNK

CHILLED WATER SUPPLYCHS

CHILLED WATER RETURNCHR

ARCHITECTURAL SCALES

SCALE 1 1/2" = 1'- 0"

DETAIL

NUMBER OF SHEET ON

WHICH DETAIL IS INDICATED

(SCALE AT WHICH DETAIL IS DRAWN)

SYMBOL WHERE DETAIL IS TAKEN

NUMBER OF SHEET ON

WHICH DETAIL IS DRAWN

DETAIL IDENTIFICATION

NUMBER

DETAIL CROSS REFERENCE

NORTH ARROW ALWAYS

POINT TRUE NORTH

4' 02' 8' 12'4'

GRAPHIC SCALE: = 1'-0"1/4"

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"

X

X-XXX

X

X-XXX

MISCELLANEOUS SYMBOLS

1. INTENT OF THE DRAWINGS

THE DRAWINGS ARE DIAGRAMMATIC AND SHOW THE GENERAL LOCATION OF DUCTWORK, PIPING, AND EQUIPMENT.

THE DRAWINGS DO NOT SHOW ALL NECESSARY OFFSETS, TRANSITIONS, AND ADJUSTMENTS NECESSITATED BY COORDINATION WITH OTHER TRADES. THE COST OF ALL OFFSETS, TRANSITIONS, AND ADJUSTMENTS NECESSITATED BY COORDINATION WITH OTHER TRADES SHALL BE INCLUDED IN THE CONTRACTOR'S BID.

FINAL PRODUCT SHALL BE A COMPLETE AND FUNCTIONING SYSTEM, AND SHALL CONFORM TO ALL REQUIREMENTS OF APPLICABLE FEDERAL, STATE, AND LOCAL CODES, INCLUDING BUT NOT LIMITED TO THE INTERNATIONAL

BUILDING CODE AND INTERNATIONAL MECHANICAL CODE.

2. COORDINATION WITH OTHER TRADES

EXAMINE AND REVIEW THE CONTRACT DOCUMENTS OF ALL DIVISIONS IN ORDER TO COORDINATE THE

INSTALLATION OF WORK.

COORDINATION SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO, VERIFYING THE LOCATION AND SIZE OF OPENINGS IN FLOORS, WALLS, PARTITIONS, CEILINGS, AND ROOFS WITH THE INSTALLING TRADES; ALLOCATION OF SPACE WITH OTHER TRADES INSTALLING WORK IN CHASES, SHAFTS, CEILING INTERSTITIAL SPACES, AND EQUIPMENT SPACES; AND THE PHASING OF INSTALLATION WORK WITH THAT OF OTHER TRADES. COORDINATE SEISMIC AND ATFP BRACING WITH ALL TRADES. COMMISSIONING REQUIREMENTS AND PROCEDURES ARE LOCATED IN THE

SPECIFICATION 01 46 00.00 06.

3. EQUIPMENT

INSTALL ALL EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS, THE

SPECIFICATIONS, AND APPROVED SHOP DRAWINGS.

MAINTAIN SERVICE AND OPERATING CLEARANCES AROUND ALL SIDES OF EACH PIECE OF EQUIPMENT IN

ACCORDANCE WITH THE MANUFACTURER'S PRINTED REQUIREMENTS AND RECOMMENDATIONS.

ALL SUSPENDED EQUIPMENT OVER 31 LBS SHALL HAVE ANGLE BRACING SIZED TO RESIST 1/2 THE WEIGHT AS

HORIZONTAL FORCES.

PROVIDE LOW LEAKAGE DAMPERS (MAXIMUM LEAKAGE RATE OF 3 CFM/SF WITH A DIFFERENTIAL PRESSURE OF ONE INCH OF WATER GAGE ACROSS THE DAMPER) FOR ALL MOTORIZED DAMPERS, OUTSIDE AND EXHAUST AIR

OPENINGS.

EQUIPMENT (PIPING, DUCTWORK, ETC) THAT DOES NOT SERVE THE IT SPACES SHALL NOT BE INSALLED ABOVE, BELOW (IE IN SLAB) OR IN THESE IT SPACES NOR WILL THIS EQUIPMENT PASS THROUGH OR ENTER THE SPACE.

ANY MOTOR, TRANSFORMER, OR OTHER ELECTRICAL DEVICE GREATER THAN 5 KVA SHALL HAVE A MINIMUM OF A 47

INCH BUFFER FROM ANY WALL OF THE EF, TER, OR TR ROOMS.

4. DUCTWORK

DUCTWORK SIZES INDICATED ON CONTRACT DOCUMENTS ARE AIR SIZE ONLY AND DO NOT INCLUDE AN

ALLOWANCE FOR INSULATION.

PROVIDE ALL DUCTWORK IN ACCORDANCE WITH THE SPECIFICATIONS, PLANS, DETAILS, AND THE DUCT CONSTRUCTION SCHEDULE. INSULATE ALL EXHAUST DUCTWORK TO AN ENERGY RECOVERY DEVICE AS IF IT WERE

SUPPLY DUCTWORK.

PAINT ALL SURFACES FLAT BLACK THAT ARE VISIBLE THROUGH GRILLES AND REGISTERS.

CENTER ALL DIFFUSERS WITHIN SQUARE CEILING TILES, AND CENTER IN EITHER THE RIGHT OR LEFT HALF OF 24" X 48" RECTANGULAR CEILING TILES. COORDINATE ALL DIFFUSER LOCATIONS WITH THE ARCHITECTURAL REFLECTED

CEILING PLANS.

PROVIDE ACCESS DOORS IN DUCTWORK FOR ALL FIRE DAMPERS, SMOKE DAMPERS, CONTROL DAMPERS, DUCT- MOUNTED COILS, AIRFLOW MEASURING STATIONS, AND CONTROL DEVICES. PROVIDE ACCESS DOORS SIZED AND LOCATED AS NECESSARY FOR INSPECTION, MAINTENANCE, CLEANING, AND ADJUSTMENT OR AS REQUIRED BY THE

MANUFACTURER.

PROVIDE REMOTE OPERATING DEVICES FOR ALL AIR BALANCING DEVICES LOCATED ABOVE INACCESSIBLE CEILINGS, UNLESS AN ACCESS DOOR HAS BEEN INDICATED ON THE ARCHITECTURAL DRAWINGS FOR THAT

PURPOSE.

PROVIDE DUCT RUN-OUTS TO REGISTERS, GRILLES & DIFFUSERS SAME SIZE AS THE DEVICE NECK UNLESS NOTED OTHERWISE ON THE DRAWINGS. SEE AIR DEVICES SCHEDULE FOR NECK SIZES. FITTINGS AND REDUCERS ARE

PROHIBITED IMMEDIATELY BEFORE TERMINAL BOXES.

PROVIDE DUCT RUN-OUTS TO TERMINAL BOXES SAME SIZE AS TERMINAL BOX INLET UNLESS NOTED OTHERWISE ON

THE DRAWINGS.

PROVIDE ALL SQUARE, 90° DUCT ELBOWS WITH DOUBLE THICKNESS TURNING VANES SPACED 1-1/2" APART

WHETHER SHOWN ON PLANS OR NOT UNLESS SPECIFICALLY NOTED OTHERWISE.

DUCTWORK SHALL BE SEAL CLASS A.

ALL OUTDOOR INTAKE LOUVERS SHALL BE A MINIMUM OF 10' ABOVE THE FINISHED GRADE.

5. PIPING

FOR COPPER TUBING USED IN REFRIGERANT SERVICE, THE DIAMETER INDICATED ON THE DRAWINGS REFERS TO

THE ACTUAL O.D. OF THE TUBING.

PROVIDE ALL PIPING IN ACCORDANCE WITH THE SPECIFICATIONS, THE PIPING PLANS AND DETAILS, AND THE PIPE

INSULATION SCHEDULE.

PIPING SCHEMATICS AND DIAGRAMS SHOW ONLY THE BASIC FLOW PATTERN AND EQUIPMENT ARRANGEMENT, AND DO NOT SHOW ALL TERMINAL EQUIPMENT CONNECTED TO THE SYSTEM. REFER TO THE PLANS, SECTIONS AND

DETAILS FOR DETAILED SYSTEM LAYOUT.

ALL ELBOWS SHALL BE LONG RADIUS UNLESS OTHERWISE NOTED. MINIMUM PIPE SIZE TO EQUIPMENT IS 3/4"

UNLESS OTHERWISE NOTED.

CONDENSATE DRAINS SHALL BE SUPPLIED FOR ALL COOLING EQUIPMENT. CONTRACTOR SHALL INSURE PROPER INSTALLATION AND DRAINAGE AS REQUIRED BY FEDERAL, STATE, AND LOCAL CODES. CONDENSATE PIPING SHALL

BE COPPER, SLOPED AT 1/8" PER FOOT MINIMUM.

ALL PIPING AND DUCTWORK SHALL HAVE THE SERVICE AND SIZE LABELED WHERE THEY ENTER AND LEAVE AN

AREA.

MECHANICAL GENERAL NOTES

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

AB

BR

EV

IA

TI

O

N S, L

EG

E N

D A

N D

G

EN

ER

AL

N O

TE

S

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

B.

E

W

IN

G

S.

F

LU

TY

M . M

U

LL

IN

S

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

M-001

D . H

EN

SL

EY

MECHANICAL ABBREVIATIONSMECHANICAL LEGEND

HGBP HOT GAS BYPASS

HGRH HOT GAS REHEAT

HTG HEATING

HTR HEATER

Hz HERTZ

LAT LEAVING AIR TEMPERATURE

LFT LEAVING FLUID

TEMPERATURE

LVR LOUVER

MAU MAKEUP AIR UNIT

MCA MAXIMUM CIRCUIT AMPS

NC NOISE CRITERIA OR

NORMALLY CLOSED

NIC NOT IN CONTRACT

NO NUMBER OR NORMALLY

OPEN

NOM NOMINAL

NTS NOT TO SCALE

OA OUTSIDE AIR

OAT OUTSIDE AIR TEMPERATURE

PD PRESSURE DROP

PH PHASE

PHC PREHEAT COIL

RA RETURN AIR

RH RELATIVE HUMIDITY

RHC REHEAT COIL

RHG REFRIGERANT HOT GAS

DISCHARGE

RL REFRIGERANT LIQUID

RLA RATED LOAD AMPS

RLF RELIEF

RPM REVOLUTIONS PER MINUTE

RS REFRIGERANT SUCTION

SA SUPPLY AIR

SAF SUPPLY AIR FAN

SD SMOKE DAMPER

SP STATIC PRESSURE

SPEC SPECIFICATIONS

T THERMOSTAT

TB TERMINAL BOX

TD TEMPERATURE DIFFERENCE

OR TRANSFER DUCT

TEMP TEMPERATURE

TSP TOTAL STATIC PRESSURE

TSTAT THERMOSTAT

UC UNDERCUT

UH UNIT HEATER

V VOLT OR VENT

VAV VARIABLE AIR VOLUME

VCD VOLUME CONTROL DAMPER

VFD VARIABLE FREQUENCY

DRIVE

W WATT

WB WET BULB

WG WATER GAUGE

(E) EXISTING TO REMAIN

ACU AIR CONDITIONING UNIT

AHU AIR HANDLING UNIT

AI ANALOG INPUT

AMP AMPERE

AO ANALOG OUTPUT

APD AIR PRESSURE DROP

ASJ ALL SERVICE JACKET

ATM ATMOSPHERE

AUTO AUTOMATIC

BAS BUILDING AUTOMATION

SYSTEM

CHR CHILLED WATER RETURN

CHS CHILLED WATER SUPPLY

COND CONDENSER OR

CONDENSATE

CU CONDENSING UNIT

CUH CABINET UNIT HEATER

DB DRY BULB

DDC DIRECT DIGITAL CONTROL

DEG DEGREE

DI DIGITAL INPUT

DIA DIAMETER

DIFF DIFFERENTIAL

DO DIGITAL OUTPUT

DOAS DEDICATED OUTSIDE AIR

SYSTEM

DP DIFFERENTIAL PRESSURE

EAT ENTERING AIR

TEMPERATURE

ECM ELECTRONICALLY

COMMUTATED MOTOR

EF EXHAUST FAN

EFT ENTERING FLUID

TEMPERATURE

EH ELECTRIC HEATER

ERU ENERGY RECOVERY UNIT

ESP EXTERNAL STATIC

PRESSURE

EVAP EVAPORATOR

EX EXISTING

EXH EXHAUST

F OR DEG

F

DEGREES FAHRENHEIT

FD FIRE DAMPER OR FLOOR

DRAIN

FLA FULL LOAD AMPS

FRP FIBERGLASS REINFORCED

PLASTIC

GA GAUGE

GALV GALVANIZED

GR/LB GRAINS OF MOISTURE PER

LB OF DRY AIR

NOTE:

LEGEND APPLIES TO ALL HVAC SHEETS. NOT ALL SYMBOLS ARE USED ON THIS PROJECT.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

10/27/2023

A B

E

SL

F

M C

M

W

2Q R

R

_P la ns _V ol 5-

M M

E

M

ASSEMBLY HALL

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

SCULLERY

DRINK CLOSET

MEN'S

RESTROOM

KHD-1

CORRIDOR

CORRIDOR

MECH

CHAIR STORAGE

VEST.

STORAGE

JAN

CLOSET

KITCHEN

CORRIDOR

S1A

TB-102

TB-105

TB-104

TB-107B

TB-101

TB-107A

S1C

S1C

S1A

R1A1000

R1E S1B

TYP. 21000

R1E

TB-118

TYP. 2

T1G

AC-2

CU-2

16Ø SA

12x12 SA

24Ø SA

16x14 SA

16x16 RA

22x20 RA

28x28 RA

12x12 SA

16x14 SA

18x22 KEA

16Ø SA

20Ø SA

Ø S

A

14x12 SA 12x10 SA

12x10 SA 14x12 SA

12x12 SA

12x12 SA

CEF-1

R4A90

S4A

22Ø SA

30x16 SA

10Ø

S1B

TYP. 4

S1B

TYP.4

R1E

S1B

TYP. 4

S1B

TYP. 4

8x6 RA

8x8 SA

S4A

R2A

T1G

6 8 9 10

E

A

B

C

D

12Ø SA

10x10 SA

TB-103

SF-3

18x18 TA

14x12 SA

14x14 SA

8x4 SA

12x10 SA

10x8 EA

12Ø SA

MAIN T.R.

WOMEN'S

RESTROOM

KEF-2

KHD-2

MH111

E1B

TYP 2

E2A

E1B

TYP 2

R1E

CLASSROOM

CLASSROOM

S1B

TYP. 4

R1E

S1B

TYP. 4

6Ø SA

S1A

TYP. 8

S1A

T1G

S1B

S1B

S1A

CLASSROOM

S1A

TYP. 8

18x18 TA

14x14 TA

JAN

TB-108B

TB-108A

20x20 RA

10x10 SA

10x10 SA

10Ø SA

R1E650

R1E

R1E

10x10

10x10 SA

Ø

S A

E1B

TYP. 2

T1E

20Ø SA

12Ø SA

LV-3

TB-108B

M-501

M-503

M-503

M-503

M-504

M-505

M-504

M-504

12x12 RA 12x12 RA

12x12 RA

12x12 RA

6 6

66666

M

AT

C H

LI

N

E -S

EE

M

H

M-301

22x20 SA

20x22 SA

TYP. 4

16x24 OA MAU-1

S1B

TB-106

12x10 SA

D

KHD-1

10x18 KEA KEF-28x12 EA

KHD-2

M-504

M-504

M-504

16x30 SA

4' 02' 8' 12'4'

GRAPHIC SCALE: = 1'-0"1/4"GRAPHIC SCALE: = 1'-0"

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

F

LO

O R

P

LA

N

H V

AC

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

B.

E

W

IN

G

S.

F

LU

TY

M . M

U

LL

IN

S

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

MH111

D . H

EN

SL

EY

SHEET KEYNOTES

1 22"Ø SUPPLY AIR DUCTWORK FROM AHU-1. SEE MH112

FOR CONTINUATION.

2 28x28 RETURN AIR DUCTWORK TO AHU-1. SEE MH112 FOR

CONTINUATION.

3 22"Ø SUPPLY AIR DUCTWORK FROM AHU-1. SEE MH112

FOR CONTINUATION.

4 PROVIDE 6" ROUND WALL CAP WITH BIRD SCREEN.

5 BALANCE AIRFLOW FOR MAKE UP AIR HOOD TO 770 CFM

EACH SUPPLY TAP.

6 OPERABLE WINDOW SENSOR. SEE CONTROLS DRAWINGS

FOR MORE INFORMATION.

GENERAL SHEET NOTES

1 SEE SHEET M-001 FOR GENERAL NOTES, LEGEND AND

SYMBOLS.

SCALE: 1/8" = 1'-0"

PARTIAL FLOOR PLAN - HVAC

SCALE: 1/4" = 1'-0"MH111

KITCHEN HOOD SECTION2

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

10/27/2023

A B

E

SL

F

M C

M

W

2Q R

R

_P la ns _V ol 5-

M-411

SF-1

DH-1

CAGE STORAGE

TB-EA1

S3A

TYP. 8

x2

R

A

22x20 EA 22x14 EA

14x14 EA x1

SA

14x12 SA

12x8 SA

30Ø SA

2 3 4 5 6

E

A

B

C

D

3.5

TB-110

S1A

ARMS VAULT

16x14 SA

12x12 SA12x12 SA 12x12 SA

16x14 SA

12x8 EA

14x14 EA

14x14 EA

8x8 EA

Ø

S A

S4CTYP 12

12x8 SA

14x12 SA

10x14 EA

CH-1

M-301

22x22 SA

TYP. 12

T2C

TYP. 12

T2C

18x14 EA

20x18 SA

18x18 TA

ARMORER

16x14 SA

6Ø SA

E2DTYP 5

M-503

M-505

M-505

M-505

M

AT

C H

LI

N

E -S

EE

M

H

22Ø SA

MATCHLINE - SEE MH113

M-503

M-503

M-504

AF

M

S

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

F

LO

O R

P

LA

N

H V

AC

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

B.

E

W

IN

G

S.

F

LU

TY

M . M

U

LL

IN

S

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

MH112

D . H

EN

SL

EY

SHEET KEYNOTES

1 SUPPLY DUCTWORK FOR ARMS VAULT LOCATED ABOVE

VAULT LID. SF-1 LOCATED BELOW CAGE STORAGE HARD

CEILING.

2 SUPPLY AND EXHAUST DUCTWORK FOR UNIT STORAGE

AREAS ARE LOCATED BELOW HARD CEILING.

3 DH-1 LOCATED INSIDE VAULT. DRAIN TO FLOOR DRAIN.

4 14x14 EXHAUST/RETURN AIR TO MECH ROOM. REFER TO

SHEET M-411 FOR CONTINUATION.

5 SUPPLY AIR DIFFUSERS LOCATED IN THE CONCRETE

CEILING OF THE ARMS VAULT.

6 DUCTWORK LOCATED ABOVE ARMS VAULT LID.

7 COVER OPENING WITH 1/4x1/4 MESH GALV HARDWARE

CLOTH.

GENERAL SHEET NOTES

1 SEE SHEET M-001 FOR GENERAL NOTES, LEGEND AND

SYMBOLS.

SCALE: 1/8" = 1'-0"

PARTIAL FLOOR PLAN - HVAC

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

10/27/2023

A B

E

SL

F

M C

M

W

2Q R

R

_P la ns _V ol 5-

M

E

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE 145

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

T.R.

ELEC

CAGE STORAGE

SF-2

AC-4

AC-3

RF-1

CU-4

CU-3

CORRIDOR

TB-111

TB-117

TB-116

TB-115 105

S1A

S1A

R1A

R1A

R1A

S1A

S1A

R1A

R1A

S1A

R1A

S1A

S1A

R1A

R1A

S1A

S1A

R1A

R1A

S1A

S1A

R1A

R1A

S1A

R1A

S1A

S1A

R1A

S1A

S1A

R1A

R1A

R1A

R1A

S1B

S1A

R1B

R1A

8x8 SA 10x8 SA 10x8 RA

12x12 RA

10Ø SA

10x8 SA8x8 SA 14x14 RA

18x16 RA

8x8 SA 10x8 SA

14Ø SA

12Ø SA

16x14 SA

20x18 SA

22x22 SA

12x12 SA 12x12 SA

12x12 SA 12x12 SA

12x12 SA 12x12 SA

32x30 RA

S4A

R3A

30x30 RA

22x22 EA

28x28 RA

1 2 3 4 5 6 8

E

F

G

H

J

73.5

TB-112

TB-113

TB-114

ARMORER

S4CTYP 12

E2C TYP 5

E2CTYP 5

18x16 EA

18x16 EA

16x14 EA

12x12 EA 12x12 EA

16x14 EA

30Ø SA

OFFICE

OFFICE

OFFICE

8Ø SA6Ø SA

6Ø SA6Ø SA

6Ø SA

8Ø SA

2 2

S4B

TYP.2

M-501

M-503 2M-503

M-503

M-504

M-505

M-505

(ABV)

(BLW)

MATCHLINE - SEE MH112

AF

M

S

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

F

LO

O R

P

LA

N

H V

AC

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

B.

E

W

IN

G

S.

F

LU

TY

M . M

U

LL

IN

S

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

MH113

D . H

EN

SL

EY

SHEET KEYNOTES

1 SUPPLY AND EXHAUST DUCTWORK FOR UNIT STORAGE

AREAS LOCATED BELOW HARD CEILING.

2 FOR CONTINUATION SEE ENLARGED MECHANICAL PLAN,

SHEET M-411.

3 OPERABLE WINDOW SENSOR. SEE CONTROLS DRAWINGS

FOR MORE INFORMATION.

4 BALANCING DAMPER IN VERTICAL. TYPICAL FOR RETURN

RUNOUTS FROM OFFICES TO CORRIDOR 128.

5 AFMS TO BE INSTALLED PER SPECIFIC MANUFACTURER'S

INSTRUCTION IN STRAIGHT DUCTWORK. PIEZO RINGS AT

THE FANS ARE ALSO ACCEPTABLE FOR AFMS.

GENERAL SHEET NOTES

1 SEE SHEET M-001 FOR GENERAL NOTES, LEGEND AND

SYMBOLS.

SCALE: 1/8" = 1'-0"

PARTIAL FLOOR PLAN - HVAC

HOUSEKEEPING

PADS TYP

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

10/27/2023

A B

E

SL

F

M C

M

W

2Q R

R

_P la ns _V ol 5-

T

CO2

H T

CO2

H

T

CO2

H

T

T

H

CO2

T

CO2HT

CO2HTCO2HT

TCO2 H

T

E

TB-104

TB-105

TB-101

TB-102

TB-107B

TB-118

CU-2

AC-2

2" CHR

3/4" RL

3/4" CD

6 8 9 10

E

A

B

C

D

TB-103

1 1

CLASSROOM

CLASSROOM

VEST.

C O

R R

ID

O

R

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CORRIDOR

CHAIR STORAGE

MECH

ASSEMBLY HALL

STORAGE

DRINK CLOSET

KITCHEN

SCULLERY

CORRIDOR

TB-108B

TB-108A

T H

2" CHS

DP

MAIN T.R.

TB-107A

M-505

M-301

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

F

LO

O R

P

LA

N

PI

PI

N G

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

B.

E

W

IN

G

S.

F

LU

TY

M . M

U

LL

IN

S

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

MP111

D . H

EN

SL

EY

SCALE: 1/8" = 1'-0"

PARTIAL FLOOR PLAN - PIPING

SHEET KEYNOTES

1 OCCUPANCY SENSOR PROVIDED BY ELECTRICAL FOR

VAV CONTROL. REFER TO SHEET M-708 FOR DETAILS.

2 CONNECT CONDENSATE TO SANITARY SEWER IN

PLUMBING CHASE. REFER TO PLUMBING FOR

CONNECTION METHOD.

GENERAL SHEET NOTES

1 SEE SHEET M-001 FOR GENERAL NOTES, LEGEND AND

SYMBOLS.

M

AT

C H

LI

N

E -S

EE

M

P1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

10/27/2023

A B

E

SL

F

M C

M

W

2Q R

R

_P la ns _V ol 5-

T H

H

CO2

T

DS

E

E

H

DH-1

CAGE STORAGE

2" CHS 2" CHR

2 3 4 5 6

E

A

B

C

D

3.5

MEN'S

RESTROOM

ARMORER

CAGE STORAGE

ARMS VAULT

CH-1

4" CHS

4" CHR

M-412

TB-110

DOAS-2

(BLW)

(ABV)

MATCHLINE - SEE MP113

M

AT

C H

LI

N

E -S

E E

M P1

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

F

LO

O R

P

LA

N

PI

PI

N G

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

B.

E

W

IN

G

S.

F

LU

TY

M . M

U

LL

IN

S

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

MP112

D . H

EN

SL

EY

SCALE: 1/8" = 1'-0"

PARTIAL FLOOR PLAN - PIPING

GENERAL SHEET NOTES

1 SEE SHEET M-001 FOR GENERAL NOTES, LEGEND AND

SYMBOLS.

2 SIZE AND INSTALL REFRIGERANT PIPING PER

MANUFACTURE'S RECOMMENDATIONS.

SHEET KEYNOTES

1 OCCUPANCY SENSOR PROVIDED BY ELECTRICAL FOR

VAV CONTROL. REFER TO SHEET M-708 FOR DETAILS.

2 ROUTE CONDENSATE TO NEAREST FLOOR DRAIN.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

10/27/2023

A B

E

SL

F

M C

M

W

2Q R

R

_P la ns _V ol 5-

H

H T

T

H T

H T

H T

H T

T

T

T H

T

E

E

H

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

T.R.

ELEC

CAGE STORAGE

AC-4

AC-3

CU-4

CU-3

CORRIDOR

TB-111

TB-117

TB-116

TB-115

3/4" CD

1 2 3 4 5 6 8

E

F

G

H

J

73.5

TB-113

TB-112

TB-114

OFFICE

OFFICE

ARMS VAULT

MECHANICAL

3/4" CD

RS/RL

RS/RL

HOUSEKEEPING

PAD TYP

DOAS-3

M-505

TB-110

MATCHLINE - SEE MP112

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

F

LO

O R

P

LA

N

PI

PI

N G

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

B.

E

W

IN

G

S.

F

LU

TY

M . M

U

LL

IN

S

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

MP113

D . H

EN

SL

EY

SCALE: 1/8" = 1'-0"

PARTIAL FLOOR PLAN - PIPING

SHEET KEYNOTES

1 ROUTE CONDENSATE FROM AC-3 AND AC-4 TO SPLASH

BLOCK. PROVIDE INSECT SCREEN OVER PIPE OPENINGS.

2 OCCUPANCY SENSOR PROVIDED BY ELECTRICAL FOR

VAV CONTROL. REFER TO SHEET M-708 FOR DETAILS.

GENERAL SHEET NOTES

1 SEE SHEET M-001 FOR GENERAL NOTES, LEGEND AND

SYMBOLS.

2 SIZE AND INSTALL REFRIGERANT PIPING PER

MANUFACTURE'S RECOMMENDATIONS.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

10/27/2023

A B

E

SL

F

M C

M

W

2Q R

R

_P la ns _V ol 5-

LEVEL 1

100' - 0"

LEVEL 2

115' - 0"

ROOF

125' - 5"

CHP-1

4" CHR

22x22 OA

ET-1

AS-1

1 2 x3

SA

22x22 RLF

22x22 RLF

20x22 RLF

30Ø SA

28x26 RA

3" CHS

3" CHR

4" CHR

18x18 RLF

LV-1

AHU-1

HOUSEKEEPING PAD

HOUSEKEEPING PAD

2" CHR

MECHANICAL

DOAS-3

3" CHR4" CHR

3" CHR

22x22 EA

(BEHIND)

TB-109

S4D

12x14 SA

18x18 RLF 30x30 RA

BT-1

POT FEEDER

M-501

M-501

M-503

M-507

30x64 RLF

30x64 RLF

60x32 RLF

(BEHIND)

(FRONT)

(FRONT)

AFMS

2 1/2" CHR

LEVEL 1

100' - 0"

LEVEL 2

115' - 0"

ROOF

125' - 5"

LV-2

1 2

2" CHR

2" CHS

14x14 EA

22x22 OA

20x22 RLF

18x18 EA

CHP-2

4" CHR

4" CHR

HOUSEKEEPING PADHOUSEKEEPING PAD

14x14 EA

24x26 OA

4" CHS

4" CHR

x2

O

A x2

R

LF

x2

EA

x2

SA

x2

EA

x2

O

A

24x26 COA

MECHANICAL

DOAS-1

DOAS-2

HOUSEKEEPING PAD

18x18 RLF

M-501

M-506

30x64 OA

30x64 OA

60x32 OA

(BEHIND)

(FRONT)

(FRONT)

AFMS3

LEVEL 1

100' - 0"

LEVEL 2

115' - 0"

ROOF

125' - 5"

B C

ARMS VAULT

SF-1

16x16 SA

S3A

S3A

14x12 SA

12x8 SA

CONCRETE

CEILING CAP

T2C

T2C

14x14 EA

M-505

M-505

M-505

2" CHS

2" CHR

LEVEL 1

100' - 0"

LEVEL 2

115' - 0"

B

2" CHS

2" CHR

R2A 95

S4A

MAU-1

HOUSEKEEPING

PAD

16x24 OA

20x22 SA

LV-3

4' 02' 8' 12'4'

GRAPHIC SCALE: = 1'-0"1/4"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

LSE

C

TI

O N

S

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

B.

E

W

IN

G

S.

F

LU

TY

M . M

U

LL

IN

S

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

M-301

D . H

EN

SL

EY

SCALE: 1/4" = 1'-0"M-411

NORTH MECHANICAL ROOM SECTION1

SCALE: 1/4" = 1'-0"M-411

SOUTH MECHANICAL ROOM SECTION2

GENERAL SHEET NOTES

1 SEE SHEET M-001 FOR GENERAL NOTES, LEGEND AND

SYMBOLS.

SCALE: 1/4" = 1'-0"MH112

ARMS VAULT SECTION3

SHEET KEYNOTES

1 3 FOOT DEEP PLENUM. CROSS BREAK BOTTOM WITH

DRAIN BACK TO LOUVER.

2 VARIABLE FREQUENCY DRIVES, TYP.

3 AFMS TO BE INSTALLED PER SPECIFIC MANUFACTURER'S

INSTRUCTION IN STRAIGHT DUCTWORK. PIEZO RINGS AT

THE FANS ARE ALSO ACCEPTABLE FOR AFMS.

SCALE: 1/4" = 1'-0"MH111

MECHANICAL ROOM 148 SECTION4

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

10/27/2023

A B

E

SL

F

M C

M

W

2Q R

R

_P la ns _V ol 5-

M

MM

M

CHP-2

CHP-1

LV-2

30Ø SA

x1

R

LF

30x30

M-301

30x30 RA 4

M-301

24x26 COA

30x30 SA

28x26 RA

1 2

E

B

C

D

CU-1

AC-1

x2

EA

AHU-1

LV-1

22x22 RLF

22x20 RLF

22x14 EA

CAGE STORAGE

MECHANICAL

ELECTRICAL

14x14 EA

22x22 EA

14x14 EA

22x22 SA

22x22 OA 22x22 OA

22x20 RLF

22x22 OA

DOAS-3

DOAS-2DOAS-1

T

HOUSEKEEPING

PAD TYP

E2D

E2D

18x18 RLF

22x22 OA

CH-1

18x18 RLF

18x18 RLF

AFMSAFMS

AF

M

SAF

M

S

AF

M

S

AFMS

22x24 EA

TB-109

S4D

TYP. 2

14x12 SA

TB-EA2

14x12 EA

E2D

TYP.2

14x12 EA

18x18 EA x2

SA

M-501

M-501

M-503

M-503

M-504

32x60 RLF

64x30 RLF

64x30 RLF

(BELOW)

(ABOVE)

32x60 OA

64x30 OA

64x30 OA

(BELOW)

(ABOVE)

7 7

26x24 OA

13 13

AF

M

S 13

4' 02' 8' 12'4'

GRAPHIC SCALE: = 1'-0"1/4"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

EN

LA

R G

ED

P

LA

N

H

V

AC

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

B.

E

W

IN

G

S.

F

LU

TY

M . M

U

LL

IN

S

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

M-411

D . H

EN

SL

EY

SHEET KEYNOTES

1 30x30 RETURN AIR FROM CLASSROOMS, OFFICES, AND

ASSEMBLY AREAS TO AHU-1.

2 30Ø SUPPLY AIR FROM AHU-1 TO CLASSROOMS, OFFICES

AND ASSEMBLY AREAS.

3 14x14 EXHAUST FROM BATHROOM AREA . REFER TO

SHEET MH112 FOR CONTINUATION.

4 22x22 EXHAUST AIR FROM CAGE STORAGE TO DOAS-3.

REFER TO SHEET MH113 FOR CONTINUATION.

5 22x22 SUPPLY AIR FROM DOAS-2 TO CAGE STORAGE.

REFER TO SHEET MH112 FOR CONTINUATION.

6 BAS CONTROL PANEL.

7 VARIABLE FREQUENCY DRIVES.

8 22x14 EXHAUST AIR FROM CAGE STORAGE TO DOAS-2.

REFER TO SHEET MH112 FOR CONTINUATION.

9 22x22 SUPPLY AIR FROM DOAS-3 TO CAGE STORAGE.

REFER TO SHEET MH113 FOR CONTINUATION.

10 ALL DUCTWORK IN MECHANICAL ROOM SHALL BE

INSULATED.

11 3 FOOT DEEP PLENUM. CROSS BREAK BOTTOM WITH

DRAIN BACK TO LOUVER.

12 VARIABLE FREQUENCY DRIVE FOR RF-1.

13 AFMS TO BE INSTALLED PER SPECIFIC MANUFACTURER'S

INSTRUCTION IN STRAIGHT DUCTWORK. PIEZO RINGS AT

THE FANS ARE ALSO ACCEPTABLE FOR AFMS.

GENERAL SHEET NOTES

1 SEE SHEET M-001 FOR GENERAL NOTES, LEGEND AND

SYMBOLS.

SCALE: 1/4" = 1'-0"MH112

ENLARGED MECHANICAL ROOM - HVAC1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

10/27/2023

A B

E

SL

F

M C

M

W

2Q R

R

_P la ns _V ol 5-

M-301

M-301

1 2

E

B

C

D

CHP-2

CHP-1

4" CHS

3" CHS

3" CHR

4" CHR

AS-1

ET-1

4" CHR

CU-1

AC-1

4" CHS

4" CHR

3/4" CD

AHU-1

CAGE STORAGE

MECHANICAL

ELECTRICAL

2" CHR

2" CHS

1 1

T

2" CHR

2" CHS

2 1/2" CHS 2 1/2" CHR

2 1/2" CHS 2 1/2" CHR

DOAS-3

DOAS-2DOAS-1

T

BT-1

HOUSEKEEPING

PAD TYP

3" CHS

POT FEEDER

CH-1

TB-109

TB-EA2

3" CHR

4" CHR

2 1/2" CHS 2 1/2" CHR4" CHS

M-501

M-501

M-501

M-505

M-506

M-507

6 6

4' 02' 8' 12'4'

GRAPHIC SCALE: = 1'-0"1/4"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

EN

LA

R G

ED

P

LA

N

PI

PI

N

G

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

B.

E

W

IN

G

S.

F

LU

TY

M . M

U

LL

IN

S

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

M-412

D . H

EN

SL

EY

SCALE: 1/4" = 1'-0"MP112

ENLARGED MECHANICAL ROOM - PIPING1

SHEET KEYNOTES

1 ROUTE CONDENSATE TO NEAREST FLOOR DRAIN.

2 ROUTE CONDENSATE TO SPLASH BLOCK. PROVIDE

INSECT SCREEN OVER PIPE OPENING.

3 2" CHS/R PIPING TO MAU-1.

4 1" COLD WATER MAKE-UP. REFER TO PLUMBING

DRAWINGS.

5 BAS CONTROL PANEL.

6 VARIABLE FREQUENCY DRIVES.

7 PIPE SUPPORTS. SEE SPECIFICATIONS.

GENERAL SHEET NOTES

1 SEE SHEET M-001 FOR GENERAL NOTES, LEGEND AND

SYMBOLS.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

10/27/2023

A B

E

SL

F

M C

M

W

2Q R

R

_P la ns _V ol 5-

FINAL FILTER

PRE FILTER

MIXING BOX CHILLED WATER

COOLING COIL

SUPPLY FAN

(6") HOUSE

KEEPING PAD

ACCESS

DOOR

RETURN

AIR INLET

FACTORY INSTALLED

INTERNAL FAN ISOLATIONOUTSIDE AIR INLET

FROM DOAS-1

SUPPLY

AIR

OUTLET

SUPPLY DIFFUSER

EXTERNAL DUCT

WRAP INSULATION

SPIN-IN FITTING

W/VOLUME DAMPER

VOLUME DAMPER

ACOUSTICAL CEILING TILE

EXTERNALLY INSULATED

RIGID 90° ELBOW SUPPLY AIR

DUCT

FLEX DUCT - LENGTH

NOT TO EXCEED 60"

PROVIDE MAXIMUM SIZE DOOR POSSIBLE IN DUCT

16"x16" 24"x24"

2-S 2-S

16"x16" 24"x24"

1-S,1-T,1-B 2-S,1-T,1-B

16"x16" 24"x24"

2-S,1-T,1-B 2-S,2-T,2-B

BUTT HINGE 1"x1", OR

PIANO HINGE

LOCK TYPE 1

SASH

LOCK

LOCK TYPE 2

FRAME 2

DUCT

DOOR B

FRAME 2

HINGE POS. 2

FRAME 3

HINGE POS. 3

DOOR A

GASKET DUCT

ACCESS PANEL

PANEL IS DUCT THICKNESS (MIN)

WITH SCREWS AT 8" MAX SPACING

DUCT

2" W.G.

STATIC

& LESS

3" W.G.

STATI

C

4" W.G.

TO

10" W.G.

DOOR

SIZE

S=SIDE OPPOSITE HINGES, T=TOP, B=BOTTOM

NO

HINGES

NO

LOCKS

METAL GAUGE THICKNESS

FRAME DOOR BACK

P

D

P

LENGTH X 2 PIPE DIA.

BEFORE TURN

DISCHARGE

SILENT SPRING

LIFT CHECK VALVE

LENGTH X 3 PIPE DIA.

SHUTOFF VALVE

FLEXIBLE

CONNECTOR

HOUSEKEEPING

PAD

DIFFERENTIAL

PRESSURE

TRANSMITTER

SUCTION

STRAINER

3/4" DRAIN

INSULATED

SUCTION

DIFFUSER

ADJ. SUPPORT FOOT

NOTES:

1. FLEXIBLE CONNECTOR TO BE MASON TYPE SDFEJ DOUBLE

SPHERICAL RUBBER/KEVLAR.

2. PROVIDE INERTIA BASE WITH SPRINGS SELECTED FOR 1" STATIC

DEFLECTION.

3. ALLOW FOR CLEARANCE REMOVING STRAINER FROM SUCTION

DIFFUSER.

4. INSTALL TEST PLUGS ON BOTH SUPPLY AND RETURN SIDE OF

PUMP.

CALIBRATED BALANCING

VALVE WITH MEMORY STOP

DOAS SIDE VIEW

NOTES:

PROVIDE ACCESS DOORS IN ALL ACCESSIBLE SECTIONS

WITH WINDOWS WHERE POSSIBLE.

OUTSIDE AIR INTAKE.

2" MERV 8 OUTDOOR AIR FILTERS

ENERGY WHEEL

DIRECT DRIVE PLENUM SUPPLY FAN AND MOTOR

SECTION. PROVIDE FACTORY VFD AND FACTORY

INSTALLED INTERNAL WIRING FOR THE FANS.

CONDITIONED OUTSIDE AIR SUPPLY.

RELIEF AIR DISCHARGE (ON THE BACK SIDE)

DIRECT DRIVE PLENUM RELIEF FAN AND MOTOR SECTION.

PROVIDE FACTORY VFD AND FACTORY INSTALLED

INTERNAL WIRING FOR THE FANS.

2" MERV 8 EXHAUST FILTERS

EXHAUST AIR INTAKE

OUTDOOR AIR DAMPER

2" MERV 13 SUPPLY FILTERS

CHILLED WATER COOLING COIL

PLAN VIEW

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

M

EC

H

AN

IC

AL

D

ET

AI

LS

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

B.

E

W

IN

G

S.

F

LU

TY

M . M

U

LL

IN

S

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

M-501

D . H

EN

SL

EY

SCALE: NTSM-501

AIR HANDLING UNIT DETAIL2

SCALE: NTSM-501

TYPICAL CEILING SUPPLY DIFFUSER CONNECTION4

SCALE: NTSM-501

DUCT ACCESS DOORS5

SCALE: NTSM-501

BASE MOUNTED PUMP3

SCALE: NTSM-501

DEDICATED OUTDOOR AIR UNIT DETAIL1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

10/27/2023

A B

E

SL

F

M C

M

W

2Q R

R

_P la ns _V ol 5-

A-307 BOLT OR WELD

CONNECTOR

CABLE ASSEMBLY TO EQUIPMENT

OVAL

SLEEVE

NO MIN

OR MAX

ATFP CABLE BRACING ATTACHMENT TO STRUCTURE ATFP BRACING CONNECTOR

SINGLE CABLE DOUBLE CABLE

HOLE DIAMETER

ACCORDING TO

BOLT SIZES.

THICKNESS SIZED FOR

EQUIPMENT WEIGHT

HOLE DIAMETER TO

ACCOMODATE CABLE.

USE ONE OR BOTH TABS

AS NEEDED.

ATFP CABLE BRACING ASSEMBLY

CABLE LOOP

CONNECTOR WITH BOLT

HOLE PER CONNECTION

BOLT DIA.

SEE DETAIL THIS SHEET

OVAL

SLEEVE

STAKE EYE AND

CABLE ASSEMBLY

TO STRUCTURE

CONNECTOR WITH

BOLT HOLE PER

CONNECTION

BOLT DIA

CABLE ASSEMBLY

TO STRUCTURE

OVAL

SLEEVE

CABLE LOOP

CONNECTOR WITH BOLT

HOLE PER CONNECTION

BOLT DIA.

SEE DETAIL THIS SHEET

ELEVATION

DOUBLE NUT (TYP)

VIBRATION ISOLATION (TYP)

SEE ATFP CABLE

ASSEMBLY

DETAIL THIS SHEET

HANGER ROD

OVAL

SLEEVE

SUSPENDED

EQUIPMENT

CABLES INSTALLED WITH 1/2"

SLACK ON BOTH SIDES

30° TO 90°

SUSPENDED

EQUIPMENT

DOUBLE NUT (TYP) SUPPORT ANGLE

SEE ATFP CABLE

ASSEMBLY

DETAIL THIS SHEET

CABLES INSTALLED WITH 1/2"

SLACK ON BOTH SIDES

SEE ATFP CABLE

ATTACHMENT

TO STRUCTURE DETAIL

VIBRATION

ISOLATION (TYP)

HANGER ROD

ELEVATION

30° TO 90°

SUSPENDED

EQUIPMENT

SUPPORT MEMBER

TRANSVERSE AND

LONGITUDINAL

CABLE BRACE

(TYP)

ATFP BRACING DETAIL FOR SUSPENDED EQUIPMENT WITH INTERNAL

VIBRATION ISOLATORS OR NO REQUIREMENT FOR VIBRATION ISOLATION

SUSPENDED EQUIPMENT:

1. ALL SUSPENDED EQUIPMENT WEIGHING OVER 31 POINDS

SHALL BE INSTALLED TO RESIST FORCES OF 0.5 TIMES THE

EQUIPMENT WEIGHT IN ANY DIRECTION AND 1.5 TIMES THE

EQUIPMENT WEIGHT IN THE DOWNWARD DIRECTION.

2. THESE DETAILS ARE PROVIDED AS GUIDANCE FOR THE

SUPPORT OF SUSPENDED EQUIPMENT WEIGHING OVER 31

POUNDS.

3. CONTRACTOR SHALL PROVIDE ON THE CONTRACT DRAWINGS

AN ATFP BRACING FOR EQUIPMENT SCHEDULE AS SHOWN

BELOW FOR ALL SUSPENDED EQUIPMENT WEIGHING 31

POUNDS AND OVER.

4. BRACING PER SEISMIC CATEGORY D OR ATFP AS DETAILED,

WHICHEVER IS MORE STRINGENT.

ANTI-TERRORISM/FORCE PROTECTION (ATFP) NOTES: EQUIPMENT

SUSPENDED

EQUIPMENT

DOUBLE NUT (TYP) SUPPORT ANGLE

SEE ATFP CABLE

ASSEMBLY DETAIL THIS

SHEET

HANGER ROD

ELEVATION

CABLES INSTALLED

TIGHT (TYP)

TY

P.

.0

0°

30° TO 90°

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

M

EC

H

AN

IC

AL

D

ET

AI

LS

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

B.

E

W

IN

G

S.

F

LU

TY

M . M

U

LL

IN

S

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

M-502

D . H

EN

SL

EY

SCALE: NTSM-502

ATFP BRACING1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

10/27/2023

A B

E

SL

F

M C

M

W

2Q R

R

_P la ns _V ol 5-

BOOT CONNECTOR

FLEXIBLE DUCT

(MAXIMUM 5 FEET

LONG)

DUCTWORK

RECTANGULAR

ROUND OR OVAL

SEAL JOINT

SEE NOTE 5 AND 8

METAL

CLAMP

DUCT

SUPPORT

SINGLE BLADE

BALANCING DAMPER

1 1/2"

3"

NOTES:

1. SUPPORT DUCTWORK AS REQUIRED.

2. BAND FLEX TO COLLAR 1/2" MINIMUM FROM

OUTBOARD END OF COLLAR.

3. INSTALL DAMPER IN OPEN POSITION; FINAL

ADJUSTMENT BY TAB CONTRACTOR.

4. PULL FLEXIBLE DUCT INSULATION UP TO END OF

BOOT AT EDGE OF RECTANGULAR

DUCTWORK; SEAL VAPOR BARRIER WITH METAL

OR PLASTIC BAND TO PREVENT MOISTURE

MIGRATION.

5. PROVIDE EXTENSION RODS TO ACCOMMODATE

INSULATION, PULL TO EDGE OF DUCTWORK AS

REQUIRED AND SEAL TO EFFECT VAPOR

BARRIER.

6. POP RIVET OR SHEET METAL SCREWS, MINIMUM 3

EACH AT 5" INTERVALS, CONNECTING

STOVEPIPE TO BOOT. ENSURE RIVETS OR

SCREWS DO NOT INTERFERE WITH DAMPER.

7. TAPE AND SEAL ALL JOINTS TO PREVENT

LEAKAGE.

8. INSTALL LOCKING QUADRANT AND HANDLE ON

BOTTOM OF DUCT FOR EASY SERVICE (SHOWN

ON TOP FOR EASE OF ILLUSTRATION ONLY).

OPPOSED BLADE

MANUAL VOLUME

DAMPER AT ALL

TAKEOFFSSEE NOTE 2

INSULATION

PER NOTE 1

WM

1/4 WM

OR 4" MIN.

MAIN AIR FLOW

SUPPLY AIR DUCT

EXHAUST AIR OR

RETURN AIR DUCT

45 MAX WM > WB

WB

BRANCH DUCT

WIDTH, WB

NOTES:

1. SUPPLY AIR AND RETURN AIR DUCT SHALL BE EXTERNALLY

INSULATED ONLY.

2. TRANSITION FITTING: USE CONICAL TEE FOR ROUND, BELL

MOUTH FOR ROUND TO PLENUM OR SHAFT, TRANSITION

TAPERED BOOT FOR RECTANGULAR. FLARE FOUR SIDES AT

AIR TRANSFERERS AND PLENUM/SHAFT CONNECTIONS.

FULL SIZE LINED SHEET METAL

BOX. HEIGHT AS REQUIRED FOR

DUCT INLET.

ROUND OR RECTANGUALR

DUCT

NOTES:

1. PROVIDE MANUAL VOLUME DAMPER IN ALL

BRANCH RETURN AND EXHAUST DUCTS

SERVING RETURN/EXHAUST GRILLES.

PAINT INSIDE

SURFACE BLACK

MANUAL VOLUME

DAMPER (OMIT

ON TRANSFER GRILLES)

OPTIONAL CONNECTION POINT

ELECTRIC HEATING COIL

DISCHARGE DUCT

MOUNT ELECTRIC HEATER

CONTROL CABINET LEFT

OR RIGHT HAND AS SPACE

REQUIREMENTS DICTATE.

(MUST BE MOUNTED WITH

AN ATTENUATOR.)

FURNISH TERMINAL UNIT WITH SINGLE

POINT ELECTRICAL CONNECTION AND

FACTORY MOUNTED FUSED

DISCONNECT.

MOUNT DAMPER ACTUATOR AND

CONTROLS LEFT OR RIGHT HAND AS

SPACE REQUIREMENTS DICTATE

EXTERNALLY INSULATE

PRIMARY AIR SUPPLY

TRANSITION

EXTERNALLY INSULATE

INLET COLLAR AND SECURE

TO TERMINAL WITH METAL

FOIL TAPE.TYPICAL TERMINAL

HANGER CONNECTION

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

M

EC

H

AN

IC

AL

D

ET

AI

LS

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

B.

E

W

IN

G

S.

F

LU

TY

M . M

U

LL

IN

S

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

M-503

D . H

EN

SL

EY

SCALE: NTSM-503

BOOT TAKE-OFF FLEXIBLE DUCT

CONNECTOR WITH DAMPER1 SCALE: NTSM-503

DUCT MAIN AND BRANCH TAKE-OFFS2

SCALE: NTSM-503

DUCTED RETURN/EXHAUST/TRANSFER GRILLE3

SCALE: NTSM-503

SINGLE DUCT VAV TERMINAL WITH ELECTRIC REHEAT4

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

10/27/2023

A B

E

SL

F

M C

M

W

2Q R

R

_P la ns _V ol 5-

WALL

CENTRIFUGAL FAN

CONDUIT HOLE

MOTOR

SPUN ALUMINUM ROOF

EXHAUSTER

MOTOR COOLING

AIR INTAKE

KITCHEN HOOD

EXHAUST DUCT; REFER TO

DRAWINGS FOR SIZES

MAKEUP AIR DUCT; REFER

TO DRAWINGS FOR SIZES

BALANCING DAMPERS

IN MAKE-UP ONLY

NOTES:

1. SLOPE EXHAUST DUCT 1/4" PER FOOT.

PITCH DUCT TO DRAIN AT LOW POINT.

2. PROVIDE ACCESS DOORS AND

CLEANOUTS IN EXHAUST DUCT PER

NFPA 96.

3. MOUNT HOOD PER MANUFACTURER'S

RECOMMNDATIONS.

4. SEE SPECIFICATIONS FOR MORE

INFORMATION.

PERFORATED AIR CURTAIN

UL LISTED LIGHT FIXTURE

UL LISTED STANDARD

BAFFLE FILTERS

EQUIPMENT

ANCHOR BOLT

D

IA

G O

N

AL

R O

D B

R

AC

IN

G

R

EQ

U

IR

ED

O

VE

R

(1 2"

0m m

STEEL ANGLE

(2"x2"x1/8") [50mmx50mmx4mm]

ROD BRACING

(TYP. 4 SIDES)

ROOF OR SLAB

STRUCTURE

3/8" INTERLOCK

BETWEEN ADJACENT

BLADES WITH FELTED

OR NEOPRENE BLADE

LIP SEALS FOR MINIMUM

AIR LEAKAGE

CONTROL SHAFT

WITH SLIDE PIN

(SEE NOTE 5)

BRONZE BEARINGS

(SEE NOTE 4)

CORNER WELD

FRAME

OPPOSED BLADE DAMPER

FRAME:

3-1/2" X 5/8" X 1/16" GALV

HAT CHANNEL WITH BLADE

STOP TOP AND BOTTOM

1/8" TIEBARS

WITH 1/8"

BRASS PIVOT

PIN WITH

LOCK

RETAINERS

PARALLEL BLADE DAMPER

3 1/2"

1/16" GALVANIZED STEEL

DAMPER BLADES (MAXIMUM

WIDTH 6-1/2")

A

A

8"

(MAX)

3 1/2"

8"

(MAX)

LIP SEAL

B B

NOTES:

1. MAXIMUM WIDTH, A, 48" PER SECTION.

2. MAXIMUM HEIGHT, B, 120" PER SECTION.

3. S.S. JAMB TO BLADE WINDSTOP NOT

SHOWN.

4. SELF LUBRICATING BRONZE BEARINGS

WITH 2" SLIDE PINS ON END OF BLADES.

5. CADMIUM PLATED CONTROL SHAFT 1/2"

SQUARE EXTENDED 6" BEYOND FRANE

WITH SLIDE PIN CONTROL.

6. DAMPER MUST MEET AMCA 511 CLASS

1A. MAXIMUM LEAKAGE RATE

ALLOWABLE 3CFM/SQFT AT A

DIFFERENTIAL PRESSURE OF 1" WG.

KITCHEN HOOD

EXHAUST DUCT; REFER TO

DRAWINGS FOR SIZES

NOTES:

1. SLOPE EXHAUST DUCT 1/4" PER FOOT.

PITCH DUCT TO DRAIN AT LOW POINT.

2. MOUNT HOOD PER MANUFACTURER'S

RECOMMNDATIONS.

3. SEE SPECIFICATIONS FOR MORE

INFORMATION.

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

M

EC

H

AN

IC

AL

D

ET

AI

LS

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

B.

E

W

IN

G

S.

F

LU

TY

M . M

U

LL

IN

S

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

M-504

D . H

EN

SL

EY

SCALE: NTSM-504

SIDEWALL EXHAUST FAN3

SCALE: NTSM-504

KITCHEN GREASE HOOD1

SCALE: NTSM-504

SUSPENDED EQUIPMENT4

SCALE: NTSM-504

PARALLEL BLADE DAMPERS5

SCALE: NTSM-504

KITCHEN CONDENSATE HOOD2

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

10/27/2023

A B

E

SL

F

M C

M

W

2Q R

R

_P la ns _V ol 5-

HANGER ROD

FLEXIBLE

CONNECTIONFLEXIBLE CONNECTION

MOTOR COVER

INLINE FAN

WASHER AND

LOCK NUT AT

MOUNTING

POINT

AIR FLOW AIR FLOW

STEEL STRUCTURE

VIBRATION ISOLATION

ASSEMBLY PER MFG.

ASSEMBLY PER MFR.

ANCHOR TO

STRUCTURE

(TYP)

TRANSITION TO

ROUND DUCT AT

FAN CONNECTION

TRANSITION TO

ROUND DUCT AT

FAN CONNECTION

8 DIA.

AIR FLOW

REFRIGERANT

RELIEF VALVE

AIR COOLED

CONDENSING

UNIT

REFRIGERANT PIPING SHALL BE

INSTALLED IN ACCORDANCE WITH

MANUFACTURER'S RECOMMENDATION

IN-LINE

FILTER-

DRYER

REFRIGERANT LIQUID

REFRIGERANT SUCTION

THERMAL

EXPANSION

VALVE

PROVIDE TRAP WITH

MINIMUM VOLUME

SUCTION HEADER

AIR FLOW

THRU COIL

REFRIGERANT

DISTRIBUTION

DUCT SIZE

1.

2.

3.

NOTE:

THE SECURITY GRILLE IS GROUTED INTO THE CEILING AS THE CEILING IS

BUILT. THE STEEL STUDS WELEDED TO THE SLEEVE FACES KEEP THE

SLEEVE FROM BEING SLIPPED OUT OF THE CEILING. THE DUCT IS THEN

CONNECTED TO THE REAR OF THE GRILLE SLEEVE.

INSIDE OF SLEEVE, SLEEVE EDGES, BACK OF SECURITY GRILLE, AND

EXTERIOR FACE OF SLEEVE, WHERE DUCT ATTACHES, WILL BE PRIMED

AND TOP COATED WITH RUSH INHIBITOR PRIMER AND TWO COATS OF

EPOXY PAINT. COLOR TO BE BLACK.

FACE AND EDGES OF SECURITY GRILLE WILL BE PRIMED AND TOP

COATED WITH RUST INHIBITOR PRIMER AND TWO COATS OF EPOXY

PAINT. COLOR TO BE BATTLE SHIP GRAY.

SECURE SIDE

NON-SECURE SIDE

1/2"X3"

STEEL STUD

EACH FACE

(TYP)

4" MIN.

1/4" STEEL SLEEVE

SCREW DUCT TO SLEEVE

WITH TAMPER PROOF NON

REMOVABLE FASTNERS

VAULT CEILING - THICKNESS.

REFER TO STRUCTURAL SECTION

FOR EXACT DIMENSION

CAULK

PERFORATED SECURITY

GRILL FACE WELDED TO

SLEEVE. SEE DETAIL "B"

DETAIL "B"

WIDTH PLUS 2"

WIDTH

DETAIL "A"

NOTES:

1. THE GRILLE IS GROUTED INTO THE WALL AS

THE WALL IS BUILT. THE TWO FACTORY WELDED

GRILLE FACES KEEP IT FROM BEING SPILLED OUT OF

THE WALL.

2. INSIDE OF THE SLEEVE AND BACK SIDE OF

SECURITY GRILLES WILL BE PRIMED AND TOP

COATED WITH RUST INHIBITOR PRIMER AND TWO

COATS OF EPOXY PAINT. COLOR TO BE BLACK.

3. SECURITY GRILLE FACES AND EDGES ON

SECURE SIDE WILL BE PRIMED AND TOP COATED

WITH RUST INHIBITOR PRIMER AND TWO COATS OF

EPOXY PAINT. PAINT TO MATCH ADJACENT WALL

COLOR.

4. SECURITY GRILLE FACE AND EDGES ON

NON-SECURE SIDE WILL BE PRIMED AND TOP

COATED WITH RUST INHIBITOR PRIMER AND TWO

COATS OF EPOXY PAINT. COLOR TO BE BATTLE SHIP

GRAY.

5. STEEL PLATE WILL BE PRIMED AND TOP

COATED (ALL SIDES) WITH RUST INHIBITOR PRIMER

AND TWO COATS OF EPOXY PAINT. PAINT TO MATCH

ADJACENT WALL COLORS.

CONTINUOUSLY WELD PLATE TO

2"x2"x1/4" THICK ANGLE

2" MIN.

SECURE SIDE NON-SECURE SIDE

MIN. 1/4" THICK

STEEL PLATE SEE

DETAIL "A"

VAULT WALL - THICKNESS,

REFER TO STRUCTURAL

SECTION FOR EXACT

DIMENSION

PERFORATED

SECURITY GRILLE

BEHIND STEEL PLATE

SEE DETAIL "B"

2" MIN.

1/4" STEEL

SLEEVE

PERFORATED

SECURITY GRILLE

WELDED TO SLEEVE

3/8" Ø x 3-1/2" LONG

EMBEDMENT EXPANSION

ANCHOR WITH TAMPER

PROOF NON REMOVABLE

FASTENER

1/2"X3" STEEL STUD EACH

FACE (TYP)

5/16" DIA HOLES

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

M

EC

H

AN

IC

AL

D

ET

AI

LS

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

B.

E

W

IN

G

S.

F

LU

TY

M . M

U

LL

IN

S

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

M-505

D . H

EN

SL

EY

SCALE: NTSM-505

SUSPENDED INLINE FAN1

SCALE: NTSM-505

DUCTLESS SPLIT SYSTEM PIPING DETAIL2

SCALE: NTSM-505

VAULT SUPPLY DETAIL3

SCALE: NTSM-505

VAULT TRANSFER DETAIL4

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

10/27/2023

A B

E

SL

F

M C

M

W

2Q R

R

_P la ns _V ol 5-

TYP. 3

SCHEDULE 40 STEEL PIPE

SPLIT PLATE FOR INSTALLATION AROUND PIPE PENETRATION -

CONTINUOUSLY WELD SEAM AFTER INSTALLATION

BUILDING SYSTEM PIPING

BLOCKED OUT HOLE

THRU SECURITY WALL

FILL VOID WITH INSULATION

CONCRETE FLOOR - THICKNESS VARIES

INSULATION

BUILDING SYSTEM PIPING

SCHEDULE 40 STEEL PIPE

INSULATION

1"

1"

2"

0"GAP (1/2" MAX. CONSTRUCTION TOLERANCE)

3/8" DIA. X 3 1/2" LONG EMBEDMENT

EXPANSION ANCHOR

HOLD DOWN CLIPS

STEEL STRUCTURE

3/8"Ø ALL THREAD ROD

STRUT CHANNEL

NUT AND WASHER

SAME SERVICE ON EACH

TRAPEZE HANGER; DO NOT

MIX HOT & COLD PIPING

16 Ga GALVANIZED PIPE

INSULATION SHIELD W/

FOAMGLASS INSERT ALL

AROUND

AHU/DOAS COOLING COIL

CHS

CHR

TEMPERATURE

PRESSURE TEST

PORT

2-WAY AUTO

MODULATING

CONTROL VALVE

BUTTERFLY/

BALL VALVE

WYE STRAINER

W/BLOW DOWN

VALVE & CAP

BAL. COCK FLOW

CONTROL DEVICE

AUTOMATIC AIR VENT: PROVIDE

PIPED DISCHARGE TO FLOOR DRAIN

UNION OR FLANGE

DRAIN VALVE

W/HOSE THREAD

ADAPTOR & CAP

THERMOMETER (TYPICAL)

PRESSURE

GAUGE

(TYPICAL)

PIPE

2 1/2"

BASE

CONCRETE

EXPANSION

SHIELD (TYP. OF 4)

2/5" BOLT W/ WASHER

(TYP. OF 4)

REDUCER

FITTING

PIPE

SADDLE

CHILLED WATER PIPE

WITH INSULATION AND

JACKET

FOAMGLASS INSULATION INSERT AT

SUPPORT; VAPOR SEAL TO ADJACENT

INSULATION (TYPICAL)

ADJUSTABLE

HEIGHT

3" PIPE (SCH

40 STEEL)

9" SQUARE

PLATE

CONCRETE PAD

MAU COOLING COIL

CHS

CHR

TEMPERATURE

PRESSURE

TEST PORT

3-WAY AUTO

MODULATING

CONTROL VALVE

BUTTERFLY/

BALL VALVE

WYE STRAINER

W/BLOW DOWN

VALVE & CAP

BAL. COCK FLOW

CONTROL DEVICE

AUTOMATIC AIR VENT: PROVIDE

PIPED DISCHARGE TO FLOOR DRAIN

UNION OR FLANGE

DRAIN VALVE

W/HOSE THREAD

ADAPTOR & CAP

THERMOMETER (TYPICAL)

PRESSURE

GAUGE

(TYPICAL)

N.O.

C

N.C.

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

,…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .