This file describes a federal solicitation and related plans volume for a construction project. The solicitation number is W912QR24R0009 from the US Army Corps of Engineers Louisville District for construction services at Fort Buchanan in Puerto Rico. The 11MB plans volume PDF provides additional details on the project scope and requirements. Responses to the solicitation are due on an unspecified date. The construction services sought relate to work at Fort Buchanan and include details on products, services, and pricing in the plans volume file.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers®

SHEET ID

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

PROJECT NO. 89301, P2# 481867

PR

O

JE

C

T N

O . 8

, P 2#

N

L

J

G

E

C

A

P

M

K

H

F

D

B

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

LOUISVILLE DISTRICT

ISSUE DATE: OCTOBER 27, 2023

CONTRACT NO.: -

SOLICITATION NO.: -

CERTIFIED FINAL SUBMITTAL

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

G-001

C O

VE

R

S H

EE

T

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

LO

U

IS

VI

LL

E D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

M .B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, D .H

EN

SL

EY

FORT BUCHANAN, PUERTO RICO

U.S. ARMY RESERVE CENTER OPERATIONS BUILDING

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

K

ER D

.A

M N

B

A M

M

10/27/2023

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/202310/27/2023

10/27/2023

10/27/2023

10/27/2023

10/27/23

VOLUME 3 OF 6

W

2Q R

R

_P la ns _V ol 3-

22 November 2023

W912QR24R0009

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

SHEET ID

P R

O J E

C T

N O

P

C E

R T

IF

IE

D F

IN

A

L S

U B

M

IT

T A

L

D R

A W

IN

G

L

IS

T

U .S

A

R M

Y R

E S

E R

V E

C E

N T

E R

O P

E R

A T

IO

N

S B

U

IL

D

IN

G

F O

R T

B U

C H

A N

A N

P

U E

R T

O R

IC

O

M B

A R

N E

T T

K R

IG

G

S

A M

C C

O Y

O C

T O

B E

R

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

G-002

D H

E N

S L E

Y

SHEET LIST

SHEET NUMBER SHEET NAME

M-713 MECHANICAL CONTROLS

ELECTRICAL

E-001 ELECTRICAL LEGEND

E-002 ELECTRICAL GENERAL NOTES & ABBREVIATIONS

EL111 PARTIAL LIGHTING PLAN

EL112 PARTIAL LIGHTING PLAN

EL113 PARTIAL LIGHTING PLAN

EL601 LIGHTING DIAGRAMS

EL701 LIGHTING SCHEDULES

EP111 PARTIAL POWER PLAN

EP112 PARTIAL POWER PLAN

EP113 PARTIAL POWER PLAN

EP130 BID OPTION 0014 - ROOF PV ARRAY PLAN

EP151 PARTIAL HVAC POWER PLAN

EP152 PARTIAL HVAC POWER PLAN

EP153 PARTIAL HVAC POWER PLAN

EP410 ENLARGED POWER PLANS

EP501 ELECTRICAL DETAILS

EP601 POWER ONE LINE DIAGRAM

EP701 PANEL SCHEDULES

EP702 PANEL SCHEDULES

EP703 PANEL SCHEDULES

EP704 PANEL SCHEDULES

EP705 PANEL SCHEDULES

EY111 PARTIAL SPECIAL SYSTEMS PLAN

EY112 PARTIAL SPECIAL SYSTEMS PLAN

EY113 PARTIAL SPECIAL SYSTEMS PLAN

EY501 SPECIAL SYSTEMS DETAILS

EG130 LIGHTNING PROTECTION PLAN

EG131 BID OPTION 0014 - LIGHTNING PROTECTION PLAN

EG501 LIGHTNING PROTECTION DETAILS

EG502 GROUNDING DETAILS

EG601 GROUNDING ONE LINE DIAGRAM

TELECOMMUNICATIONS

T-001 COMMUNICATIONS LEGENDS

T-002 COMMUNICATIONS GENERAL NOTES & ABBREVIATIONS

T-111 PARTIAL COMMUNICATIONS PLAN

T-112 PARTIAL COMMUNICATIONS PLAN

T-113 PARTIAL COMMUNICATIONS PLAN

T-410 ENLARGED COMMUNICATIONS PLANS

T-501 COMMUNICATIONS DETAILS

T-502 COMMUNICATIONS DETAILS

T-601 COMMUNICATION DIAGRAMS

T-602 COMMUNICATION ROOM 147 ELEVATION DIAGRAM

T-603 COMMUNICATION ROOM 126 ELEVATION DIAGRAM

SHEET LIST

SHEET NUMBER SHEET NAME

INTERIORS

I-001 FF&E LEGEND

I-110 COMPOSITE FURNITURE PLAN

I-111 PARTIAL FURNITURE PLAN

I-112 PARTIAL FURNITURE PLAN

I-113 PARTIAL FURNITURE PLAN

LIFE SAFETY

LS001 ABBREVIATIONS, LEGEND AND GENERAL NOTES

LS100 CODE COMPLIANCE SITE PLAN

LS110 LEVEL 1 LIFE SAFETY PLAN - COMPOSITE

FIRE PROTECTION

FP001 ABBREVIATIONS, LEGEND AND GENERAL NOTES

FP110 LEVEL 1 FIRE PROTECTION PLAN - COMPOSITE

FP501 FIRE PROTECTION DETAILS

FP502 FIRE PROTECTION DETAILS

FIRE ALARM

FA001 ABBREVIATIONS, LEGEND AND GENERAL NOTES

FA110 LEVEL 1 FIRE ALARM PLAN - COMPOSITE

FA501 FIRE ALARM DETAILS

FA502 FIRE ALARM DETAILS

PLUMBING

P-001 ABBREVIATIONS, LEGEND AND GENERAL NOTES

PP101 PARTIAL UNDERGROUND PLAN

PP102 PARTIAL UNDERGROUND PLAN

PP111 PARTIAL SANITARY PLAN

PP112 PARTIAL SANITARY PLAN

PP113 PARTIAL WATER PLAN

PP114 PARTIAL WATER PLAN

PP115 PARTIAL WATER PLAN

P-401 ENLARGED PLANS

P-402 ENLARGED PLANS

P-403 ENLARGED PLANS

P-404 ENLARGED PLANS

P-405 ENLARGED PLANS

P-406 ENLARGED PLANS

P-501 DETAILS

P-502 DETAILS

P-503 DETAILS

P-504 DETAILS

P-601 SCHEDULES

P-900 RISER DIAGRAMS

P-901 RISER DIAGRAMS

P-902 RISER DIAGRAMS

P-910 RISER DIAGRAMS

P-911 RISER DIAGRAMS

P-912 RISER DIAGRAMS

MECHANICAL

M-001 ABBREVIATIONS, LEGEND AND GENERAL NOTES

MH111 PARTIAL FLOOR PLAN - HVAC

MH112 PARTIAL FLOOR PLAN - HVAC

MH113 PARTIAL FLOOR PLAN - HVAC

MP111 PARTIAL FLOOR PLAN - PIPING

MP112 PARTIAL FLOOR PLAN - PIPING

MP113 PARTIAL FLOOR PLAN - PIPING

M-301 SECTIONS

M-411 ENLARGED PLAN - HVAC

M-412 ENLARGED PLAN - PIPING

M-501 MECHANICAL DETAILS

M-502 MECHANICAL DETAILS

M-503 MECHANICAL DETAILS

M-504 MECHANICAL DETAILS

M-505 MECHANICAL DETAILS

M-506 MECHANICAL DETAILS

M-507 MECHANICAL DETAILS

M-550 AIR RISER DIAGRAM

M-551 AIR RISER DIAGRAM

M-552 AIR RISER DIAGRAM

M-553 CHILLED WATER PIPING DIAGRAM

M-601 MECHANICAL SCHEDULES

M-602 MECHANICAL SCHEDULES

M-603 MECHANICAL SCHEDULES

M-701 MECHANICAL CONTROLS

M-702 MECHANICAL CONTROLS

M-703 MECHANICAL CONTROLS

M-704 MECHANICAL CONTROLS

M-705 MECHANICAL CONTROLS

M-706 MECHANICAL CONTROLS

M-707 MECHANICAL CONTROLS

M-708 MECHANICAL CONTROLS

M-709 MECHANICAL CONTROLS

M-710 MECHANICAL CONTROLS

M-711 MECHANICAL CONTROLS

M-712 MECHANICAL CONTROLS

SHEET LIST

SHEET NUMBER SHEET NAME

S-362 FRAMING SECTIONS

S-363 FRAMING SECTIONS

S-364 FRAMING SECTIONS

S-365 FRAMING SECTIONS

S-366 BID OPTION - SOLAR PANEL SUPPORT FRAMING SECTIONS

S-401 ENLARGED RAMP FOUNDATION/SLAB PLAN

S-402 RAMP SECTIONS

S-411 ENLARGED VAULT ROOF SLAB FRAMING PLAN

S-412 VAULT SECTIONS AND DETAILS

S-413 VAULT SECTIONS

S-501 TYPICAL FOUNDATION DETAILS

S-502 TYPICAL FOUNDATION DETAILS

S-503 PRECAST WALL PANEL DETAILS

S-511 TYPICAL FRAMING DETAILS

S-601 SCHEDULES

S-602 SPECIAL JOIST LOADING DIAGRAM

ARCHITECTURE

A-001 SYMBOL LEGEND

A-110 COMPOSITE FLOOR PLAN

A-111D PARTIAL DIMENSION PLAN

A-111N PARTIAL NOTE PLAN

A-112D PARTIAL DIMENSION PLAN

A-112N PARTIAL NOTE PLAN

A-113D PARTIAL DIMENSION PLAN

A-113N PARTIAL NOTE PLAN

A-130 COMPOSITE ROOF PLAN

A-140 COMPOSITE REFLECTED CEILING PLAN

A-141 PARTIAL REFLECTED CEILING PLAN

A-142 PARTIAL REFLECTED CEILING PLAN

A-143 PARTIAL REFLECTED CEILING PLAN

A-160 COMPOSITE PRECAST PANEL FLOOR PLAN

A-161 PRECAST PANEL ELEVATIONS

A-162 PRECAST PANEL DETAILS

A-181 PARTIAL SIGNAGE PLAN

A-182 PARTIAL SIGNAGE PLAN

A-183 PARTIAL SIGNAGE PLAN

A-200 COMPOSITE BUILDING ELEVATIONS

A-201 ENLARGED BUILDING ELEVATIONS

A-202 ENLARGED BUILDING ELEVATIONS

A-203 ENLARGED BUILDING ELEVATIONS

A-204 ENLARGED BUILDING ELEVATIONS

A-301 BUILDING SECTIONS

A-310 WALL SECTIONS

A-311 WALL SECTIONS

A-400 ENLARGED RESTROOM PLAN

A-401 RESTROOM DETAILS

A-402 TYPICAL RESTROOM MOUNTING HEIGHTS

A-410 RESTROOM ELEVATIONS

A-450 RAILING DETAILS

A-461 PARTIAL FINISH PLAN

A-462 PARTIAL FINISH PLAN

A-463 PARTIAL FINISH PLAN

A-500 DOOR AND FRAME TYPES AND ABA MANEUVERING

CLEARANCES

A-501 DOOR DETAILS

A-502 DOOR DETAILS

A-510 WINDOW TYPES & DETAILS

A-530 LOUVER TYPES AND DETAILS

A-540 WALL TYPES

A-541 WALL DETAILS

A-542 WALL DETAILS

A-550 COLUMN DETAILS

A-551 COLUMN DETAILS

A-560 CEILING DETAILS

A-570 ROOF DETAILS

A-571 ROOF DETAILS

A-580 MISCELLANEOUS DETAILS

A-600 DOOR SCHEDULE

A-610 FINISH SCHEDULE AND EXTERIOR FINISH KEY

A-611 FINISH KEYS & NOTES

A-620 SIGNAGE SCHEDULE

A-621 SIGNAGE DETAILS

A-700 ENLARGED VAULT DIMENSION PLAN

A-701 ENLARGED VAULT NOTED PLAN

A-710 ENLARGED CAGE PLANS

A-711 CAGE ELEVATIONS

A-712 CAGE SECTIONS AND DETAILS

A-713 CAGE DETAILS

A-800 ENLARGED KITCHEN PLAN

A-801 KITCHEN SCHEDULE

A-900 AIR BARRIER FLOOR PLAN

A-901 AIR BARRIER WALL SECTION

SHEET LIST

SHEET NUMBER SHEET NAME

GENERAL

G-001 COVER SHEET

G-002 DRAWING LIST

G-201 LOCATION AND VICINITY MAP

G-202 PROJECT AERIAL

CIVIL

V-101 OVERALL SITE SURVEY

V-111 SITE SURVEY

V-112 SITE SURVEY

B-101 OVERALL BORING PLAN

B-111 BORING PLAN

B-112 BORING PLAN

B-201 BORING LOGS

B-202 BORING LOGS

C-001 CIVIL LEGEND AND ABBREVATIONS

C-002 CIVIL GENERAL NOTES

CD101 OVERALL DEMOLITION PLAN

CD111 DEMOLITION PLAN

CD112 DEMOLITION PLAN

CG101 OVERALL GRADING AND DRAINAGE PLAN

CG111 GRADING AND DRAINAGE PLAN

CG112 GRADING AND DRAINAGE PLAN

CG201 STORM SEWER PROFILES & SCHEDULE

CG501 DRAINAGE DETAILS

CG502 DRAINAGE DETAILS

CG503 DRAINAGE DETAILS

CG701 OVERALL SEDIMENT AND EROSION CONTROL PLAN

CG711 SEDIMENT AND EROSION CONTROL PLAN

CG712 SEDIMENT AND EROSION CONTROL PLAN

CG801 SEDIMENT AND EROSION CONTROL NOTES

CG802 SEDIMENT AND EROSION CONTROL DETAILS

CG803 SEDIMENT AND EROSION CONTROL DETAILS

CG804 SEDIMENT AND EROSION CONTROL DETAILS

CG805 SEDIMENT AND EROSION CONTROL DETAILS

CG806 SEDIMENT AND EROSION CONTROL DETAILS

CS101 OVERALL SITE LAYOUT

CS111 SITE LAYOUT

CS112 SITE LAYOUT

CS401 JOINT LAYOUT PLAN

CS501 PAVEMENT DETAILS

CS502 PAVEMENT DETAILS

CS503 DESIGNATED SMOKING AREA SIGNAGE

CU101 OVERALL UTILITY PLAN

CU111 UTILITY PLAN

CU112 UTILITY PLAN

CU201 SANITARY SEWER PROFILES & SCHEDULE

CU501 SANITARY SEWER DETAILS

CU502 SANITARY SEWER DETAILS

CU511 WATER DETAILS

CU512 WATER DETAILS

LP101 OVERALL LANDSCAPE PLAN

LP111 LANDSCAPE PLAN

LP112 LANDSCAPE PLAN

ELECTRICAL

ES100 EXISTING ELECTRICAL SITE PLAN

ES101 ELECTRICAL SITE PLAN

ES501 SITE ELECTRICAL DETAILS

ES502 BID OPTION - SITE ELECTRICAL DETAILS

ES503 SITE ELECTRICAL DETAILS

TELECOMMUNICATIONS

TS101 COMMUNICATION SITE PLAN

STRUCTURAL

S-001 GENERAL STRUCTURAL NOTES AND DESIGN CRITERIA

S-002 GENERAL STRUCTURAL NOTES, DESIGN CRITERIA AND

ABBREVIATIONS

S-003 COMPONENTS AND CLADDING WIND LOAD DIAGRAM

S-111 PARTIAL FOUNDATION/FLOOR SLAB PLAN

S-112 PARTIAL FOUNDATION/FLOOR SLAB PLAN

S-113 PARTIAL FOUNDATION/FLOOR SLAB PLAN

S-114 SLAB ON GRADE CONTROL JOINT PLAN

S-131 PARTIAL ROOF FRAMING PLAN

S-132 PARTIAL ROOF FRAMING PLAN

S-133 PARTIAL ROOF FRAMING PLAN

S-141 BID OPTION - SOLAR PANEL SUPPORT FRAMING PLAN

S-200 PRECAST CONCRETE WALL ELEVATIONS KEY PLAN

S-211 CONCRETE WALL ELEVATIONS

S-212 CONCRETE WALL ELEVATIONS

S-213 CONCRETE WALL ELEVATIONS

S-251 OPERABLE PARTITION SUPPORT FRAMING ELEVATION AND

SECTION

S-301 FOUNDATION SECTIONS

S-302 FOUNDATION SECTIONS

S-361 FRAMING SECTIONS

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

K

ER D

.A

M N

B

A M

M

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

W

2Q R

R

_P la ns _V ol 3-

AREA OF DETAIL

NUMBER OF SHEET ON WHICH DETAIL IS DRAWN

DETAIL IDENTIFICATION NUMBER

* SYMBOL WHERE DETAIL IS TAKEN:

A-401

SCALE AT WHICH SECTION OR DETAIL IS DRAWN

NUMBERS OF SHEET WHERE SECTION OR DETAIL IS

CUT

* SUBTITLE FOR SECTION/DETAIL DRAWING:

SCALE AT WHICH ELEVATION IS DRAWN

NUMBERS OF SHEET WHERE ELEVATION IS SHOWN

* SYMBOL WHERE ELEVATION IS TAKEN

SUBTITLE FOR ELEVATION DRAWING:

A-200

ELEVATION IDENTIFICATION NUMBER

GRANULAR/GRAVEL FILL

EARTH

CONCRETE

RIGID INSULATION

BLANKET, BATT, OR LOOSE FILL INSULATION

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

GRAPHIC SCALE: = 1'-0"

1" 0 2" 3"1"

12"

½"

GRAPHIC SCALE: = 1'-0"

GRAPHIC SCALE: = 1'-0"

32' 016' 64' 96'32'

1/32"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

SY

M

BO

L

LE

G

EN

D

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-001

D . H

EN

SL

EY

REFERENCE SYMBOLOGY

SCALE: 1 1/2" = 1'-0"A-001

SECTION OR DETAIL2

SCALE: 1/8" = 1'-0"A-001

ELEVATION3

MATERIALS LEGEND

NORTH ARROW FOR PROJECT

INDICATES THE SCALE THE

DRAWING ON THE SHEET IS

DRAWN AT.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

A-200

A-200

A-200

A-200

172' - 0" 77' - 0"

249' - 0"

34' - 0" 121' - 10" 93' - 2"

5'

B

C

D

E

F

G

H

A-301

A-301

A-301

A-301

A-111N

A-111D

A-113N

A-113D

J

A

A-112D

A-112N

DRINK CLOSET

SCULLERY

ELEC

ELECTRICAL

CORRIDOR

ASSEMBLY HALL

OFFICE

OFFICE

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

MECHANICAL

MAIN T.R.

T.R.

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

WOMEN'S RESTROOM

JAN

MEN'S RESTROOM

CORRIDOR

JAN

KITCHEN

CLOSET

STORAGE

VEST.

CORRIDOR

CORRIDOR

MECH

CHAIR STORAGE

3.5

3.5

CLASSROOM

CLASSROOM

ARMS VAULT

ARMORER

5'

4"

A-450

A-450

CAGE STORAGE

128A

PRINTER

9'

0"

1'

0"

GRAPHIC SCALE: = 1'-0"

16' 08' 32' 48'16'

1/16"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

C O

M

PO

SI

TE

F

LO

O R

P

LA

N

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-110

D . H

EN

SL

EY

SCALE: 1/16" = 1'-0"

COMPOSITE FLOOR PLAN

GENERAL SHEET NOTES

1 REFER TO PARTIAL PLANS A-111 THROUGH A-113 FOR

DIMENSIONS AND NOTES.

2 REFER TO STRUCTURAL DRAWINGS FOR FINISH FLOOR

ELEVATIONS.

3 REFER TO SPECIAL ITEMS KEY FOR WINDOW COVERING.

4 TYPICAL DOORS IN STUD WALLS SHALL BE 4" FROM

NEAREST WALL UNLESS OTHERWISE INDICATED.

5 ALL DIMENSIONS ARE FROM FACE OF PRECAST

CONCRETE PANEL OR METAL STUDS, UNLESS

OTHERWISE NOTED.

6 PROVIDE CONTROL JOINTS IN GYPSUM BOARD. REFER TO

SPECIFICATIONS.

7 PROVIDE CORNER GUARDS AT OUTSIDE CORNERS IN

GYPSUM BOARD WALLS. REFER TO DETAIL 2/A-580.

8 PROVIDE 20 GA. METAL STUDS AND BLOCKING IN AREAS

OF WALL AND CEILING MOUNTED ITEMS (TV'S, MONITORS,

CAMERAS, ETC.) REFER TO ELECTRICAL AND FURNITURE

PLANS.

9 SLOPE FLOORS TO DRAIN WHERE SPECIFICALLY NOTED.

REFER TO STRUCTURAL, MECHANICAL AND PLUMBING

DRAWINGS.

10 CFCI COLLATERAL EQUIPMENT AND CFCI BONA FIDE

NEED EQUIPMENT ITEMS SHALL BE PRICED SEPARATELY.

REFER TO BID SCHEDULES.

ROOM SCHEDULE

NUMBER ROOM NAME SQUARE FOOTAGE

100 VEST. 73 SF

101 CORRIDOR 306 SF

102 CORRIDOR 323 SF

103 CLASSROOM 532 SF

104 CLASSROOM 526 SF

105 CLASSROOM 551 SF

106 CLASSROOM 554 SF

107 ASSEMBLY HALL 3806 SF

108 DRINK CLOSET 24 SF

109 CLOSET 23 SF

110 SCULLERY 163 SF

111 JAN 26 SF

112 KITCHEN 544 SF

113 STORAGE 144 SF

114 CHAIR STORAGE 443 SF

115 CORRIDOR 447 SF

116 JAN 57 SF

117 WOMEN'S RESTROOM 350 SF

118 MEN'S RESTROOM 466 SF

119 CLASSROOM 660 SF

120 CLASSROOM 599 SF

121 CAGE STORAGE 25055 SF

122 ARMORER 124 SF

123 ARMS VAULT 3111 SF

124 MECHANICAL 2300 SF

125 ELECTRICAL 286 SF

126 T.R. 48 SF

127 ELEC 72 SF

128 CORRIDOR 688 SF

128A PRINTER 23 SF

129 OFFICE 120 SF

130 OFFICE 120 SF

131 OFFICE 120 SF

132 OFFICE 120 SF

133 OFFICE 120 SF

134 OFFICE 119 SF

135 OFFICE 120 SF

136 OFFICE 120 SF

137 OFFICE 120 SF

138 OFFICE 119 SF

139 OFFICE 120 SF

140 OFFICE 120 SF

141 OFFICE 120 SF

142 OFFICE 119 SF

143 OFFICE 120 SF

144 OFFICE 120 SF

145 OFFICE 120 SF

146 OFFICE 120 SF

147 MAIN T.R. 108 SF

148 MECH 95 SF

GROSS SQ. FT. 46,666 SF

NET SQ. FT. 44,611 SF

1/2 SQ. FT (CANOPIES) 36 SF

ALLOWABLE SQ. FT. 53,690 SF

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

DRINK CLOSET

CORRIDOR

ASSEMBLY HALL

B

C

D

E

6 9 10

MEN'S

RESTROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

MAIN T.R.

JAN

10' - 7" 33' - 9" 46' - 4"

3'

7" 7'

3"

5'

4"

4'

9"

5'

4" 5'

5"

0"

8'

6'

7" 5'

4"

6'

0"

CORRIDOR

C O

R R

ID

O

R

VEST.

3' - 4"

23' - 1" 3' - 4"

7' - 4" 46' - 3 7/8"

KITCHEN

SCULLERY

STORAGE

CLOSET

JAN

5'

3"4'

0" 4'

0"

4'

0"

8'

6" 3'

4"

4'

0" 4'

0"

4'

0"

5'

5"6'

4" 5'

9"

3'

4"

1"

3'

4"

4' - 10"3' - 4" 1' - 3"

4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 31' - 7"

A

WOMEN'S

RESTROOM

76' - 5" 3' - 5" 24' - 1"

MECH

0"

7' - 4" 37' - 10" 8' - 5 7/8"

CHAIR STORAGE

A-400

M

AT

C H

LI

N

E

SE

E

1/ A-

2D

M

AT

C H

LI

N

E

SE

E

1/ A-

2D

18' - 9 3/8"

3'

4"

5' - 4"

3'

4"

5' - 4"

5' - 3 7/8"

3'

4"

3'

4"

5' - 4"

CLASSROOM

CLASSROOM

50' - 6"

15' - 5 1/2" 4' - 9" 15' - 5 1/2"

4' - 0" 4' - 0" 4' - 0" 7' - 9"7' - 9"8' - 6"

3' - 4"

15' - 5 1/2" 4' - 9" 15' - 5 1/2"

6' - 0" 5' - 6" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0"

/4

41' - 10" 10' - 6"

11' - 4"

28' - 7" 10' - 6" 10' - 3 3/4"

20' - 1 1/4"26' - 6"

21' - 11" 21' - 11"

20' - 0"20' - 0"7'

0"

2'

7"

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

D

IM

EN

SI

O N

P

LA

N

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-111D

D . H

EN

SL

EY

SCALE: 1/8" = 1'-0"A-110

PARTIAL DIMENSION PLAN1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

SCULLERY

CORRIDOR

B

C

D

E

6 9 10

DRINK CLOSET

CORRIDOR

MEN'S

RESTROOM

CORRIDOR

ASSEMBLY HALL

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

MAIN T.R.

JAN

STORAGE

KITCHEN

CLOSET

A-400

A-310

A-310

A-310100

VEST.

CORRIDOR

C O

R R

ID

O

R

A

112A

118 117

107B

107A

WOMEN'S

RESTROOM

CHAIR STORAGE

MECH

A-400

JAN

A-800

7 TYP.

7 TYP.

A A A A A

A

A

A

A

11 11

5 5

6 66

M

AT

C H

LI

N

E

SE

E

1/ A-

2N

M

AT

C H

LI

N

E

SE

E

1/ A-

2N

5 5

5 5

105106

103 104

13 13 13 13

13 13

A-550

A-550

CLASSROOM

CLASSROOM

AA

5 5

A-550

A-550

A-550

A-550

A-550

7 TYP.

7 TYP.

6 1

16 16

16 16

18 18

A-551

A-450

A-450

107C

ARCHITECTURAL LEGEND

INDICATES DOOR NUMBER.

REFER TO DOOR SCHEDULE ON SHEET A-600.

INDICATES WINDOW TYPE. REFER TO SHEET A-510.

INDICATES LOUVER TYPE. REFER TO SHEET A-530.

INDICATES WALL TYPE CONSTRUCTION.

REFER TO SHEET A-540.

INDICATES (1) HOUR RATED WALL. REFER TO LIFE

SAFETY PLANS.

INDICATES SMOKE PARTITION. REFER TO LIFE SAFETY

PLANS.

1FB

SP

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

N O

TE

P

LA

N

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-111N

D . H

EN

SL

EY

SCALE: 1/8" = 1'-0"A-110

PARTIAL NOTE PLAN1

SHEET KEYNOTES

1 SURFACE MOUNTED FIRE EXTINGUISHER BRACKET.

MOUNT BOTTOM AT 27" A.F.F.

2 4'-0" X 8'-0" TACK BOARD, MOUNT BOTTOM AT 3'-0" A.F.F.

REFER TO DETAIL 8/A-580.

3 OPERABLE ACOUSTICAL PANEL PARTITION WITH STC 45

RATING. PROVIDE METAL BLOCKING IN WALL AT JAMB.

REFER TO DETAIL 5/A-560.

4 6" WIDE BY 5" DEEP PRE-FINISHED METAL DOWNSPOUT

WITH CAST IRON DOWNSPOUT BOOT. CONNECT TO

UNDERGROUND STORM DRAINAGE SYSTEM. REFER TO

ELEVATIONS.

5 10' WIDE X 10' HIGH OVERHEAD COILING DOOR. REFER TO

DOOR SCHEDULE.

6 SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH A

10lb. FIRE EXTINGUISHER. (TO BE ONE HOUR RATED

WHEN INSTALLED IN A RATED WALL). REFER TO DETAIL

4/A-580.

7 BAHAMA STYLE HURRICANE SHUTTERS. REFER TO

DETAIL 5/A-510.

8 6'-0" WIDE BY 4'-0" DEEP ENTRANCE CANOPY. REFER TO

DETAILS ON SHEET A-570.

9 8'-4" WIDE X 12'-4" DEEP (INSIDE CLEAR SPACE) WELDED

WIRE FABRIC CAGES WITH (3) 4'-0" W X 2'-0"D X 7'-0"H

SHELVES. REFER TO SHEETS A-710 THROUGH A-713 FOR

DETAILS.

10 6" WIDE BY 5" DEEP PRE-FINISHED METAL DOWNSPOUT

WITH CONCRETE SPLASHBLOCK. REFER TO ELEVATIONS.

11 ROOF ACCESS LADDER.

12 48" X 48" ROOF HATCH ABOVE. REFER TO DETAIL 1/A-570

13 6" DIAMETER 4'-0" TALL CONCRETE FILLED PIPE BOLLARD

(AT EXTERIOR LOCATIONS). REFER TO STRUCTURAL

DRAWINGS FOR DETAILS.

14 6" DIAMETER TALL PIPE BALLARD WITH PLATE MOUNTED

BASE (AT INTERIOR LOCATIONS)

15 SECURED LOCK BOX FOR FIRE DEPARTMENT ACCESS TO

BE PROVIDED AND INSTALLED BY THE CONTRACTOR.

CONTRACTOR TO COORDINATE REQUIREMENTS WITH

THE FIRE DEPARTMENT.

16 4'-0" X 8'-0" DRY ERASE MARKER BOARD WITH MAP RAIL,

MOUNT BOTTOM AT 3'-0" A.F.F. REFER TO DETAIL 7/A-580.

WHEN BOARD IS ATTACHED TO A FIRE RATED WALL ADD

FIRE CAULK TO MAINTAIN RATING.

17 1-1/2" DIAMETER GUARDRAIL, REFER TO DETAIL 1/A-450.

18 1-1/2" DIAMETER HANDRAIL. REFER TO DETAIL 2/A-450.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

B

C

D

E

2 3 4 5 6

MECHANICAL

MEN'S

RESTROOM

ELECTRICAL

6'

4"

A

M

AT

C H

LI

N

E

SE

E

1/ A-

1D

MATCHLINE -

SEE 1/A-113D

3.5

7'

3/

8" 7'

0"

10' - 0"

0"

34' - 0"

7'

0"

7' - 0"

19' - 4"

1' - 9" 3' - 4"

19' - 1" 6' - 4"

3' - 6"

ARMORER

33' - 7" 68' - 0" 22' - 8"

M

AT

C H

LI

N

E

SE

E

1/ A-

1D

CAGE STORAGE

14' - 3"

3' - 8"

A-710 2A-710

MATCHLINE -

SEE 1/A-113D

ARMS VAULT

A-700

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

D

IM

EN

SI

O N

P

LA

N

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-112D

D . H

EN

SL

EY

SCALE: 1/8" = 1'-0"A-110

PARTIAL DIMENSION PLAN1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

C

D

E

2 3 4 5 6

MECHANICAL

MEN'S

RESTROOM

A-301

A-301

ELECTRICAL

A

121A

121B

124B

MATCHLINE -

SEE 1/A-113N

MATCHLINE -

SEE 1/A-113N

M

AT

C H

LI

N

E

SE

E

1/ A-

1N

M

AT

C H

LI

N

E

SE

E

1/ A-

1N

3.5

11ABOVE

A-310

A-310

ARMORER

ARMS VAULT

A-550

A-550

A-551

125 124A

1 1

CAGE STORAGE

A-710

A-710

A-701

107C

ARCHITECTURAL LEGEND

INDICATES DOOR NUMBER.

REFER TO DOOR SCHEDULE ON SHEET A-600.

INDICATES WINDOW TYPE. REFER TO SHEET A-510.

INDICATES LOUVER TYPE. REFER TO SHEET A-530.

INDICATES WALL TYPE CONSTRUCTION.

REFER TO SHEET A-540.

INDICATES (1) HOUR RATED WALL. REFER TO LIFE

SAFETY PLANS.

INDICATES SMOKE PARTITION. REFER TO LIFE SAFETY

PLANS.

1FB

SP

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

N O

TE

P

LA

N

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-112N

D . H

EN

SL

EY

SCALE: 1/8" = 1'-0"A-110

PARTIAL NOTE PLAN1

SHEET KEYNOTES

1 SURFACE MOUNTED FIRE EXTINGUISHER BRACKET.

MOUNT BOTTOM AT 27" A.F.F.

2 4'-0" X 8'-0" TACK BOARD, MOUNT BOTTOM AT 3'-0" A.F.F.

REFER TO DETAIL 8/A-580.

3 OPERABLE ACOUSTICAL PANEL PARTITION WITH STC 45

RATING. PROVIDE METAL BLOCKING IN WALL AT JAMB.

REFER TO DETAIL 5/A-560.

4 6" WIDE BY 5" DEEP PRE-FINISHED METAL DOWNSPOUT

WITH CAST IRON DOWNSPOUT BOOT. CONNECT TO

UNDERGROUND STORM DRAINAGE SYSTEM. REFER TO

ELEVATIONS.

5 10' WIDE X 10' HIGH OVERHEAD COILING DOOR. REFER TO

DOOR SCHEDULE.

6 SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH A

10lb. FIRE EXTINGUISHER. (TO BE ONE HOUR RATED

WHEN INSTALLED IN A RATED WALL). REFER TO DETAIL

4/A-580.

7 BAHAMA STYLE HURRICANE SHUTTERS. REFER TO

DETAIL 5/A-510.

8 6'-0" WIDE BY 4'-0" DEEP ENTRANCE CANOPY. REFER TO

DETAILS ON SHEET A-570.

9 8'-4" WIDE X 12'-4" DEEP (INSIDE CLEAR SPACE) WELDED

WIRE FABRIC CAGES WITH (3) 4'-0" W X 2'-0"D X 7'-0"H

SHELVES. REFER TO SHEETS A-710 THROUGH A-713 FOR

DETAILS.

10 6" WIDE BY 5" DEEP PRE-FINISHED METAL DOWNSPOUT

WITH CONCRETE SPLASHBLOCK. REFER TO ELEVATIONS.

11 ROOF ACCESS LADDER.

12 48" X 48" ROOF HATCH ABOVE. REFER TO DETAIL 1/A-570

13 6" DIAMETER 4'-0" TALL CONCRETE FILLED PIPE BOLLARD

(AT EXTERIOR LOCATIONS). REFER TO STRUCTURAL

DRAWINGS FOR DETAILS.

14 6" DIAMETER TALL PIPE BALLARD WITH PLATE MOUNTED

BASE (AT INTERIOR LOCATIONS)

15 SECURED LOCK BOX FOR FIRE DEPARTMENT ACCESS TO

BE PROVIDED AND INSTALLED BY THE CONTRACTOR.

CONTRACTOR TO COORDINATE REQUIREMENTS WITH

THE FIRE DEPARTMENT.

16 4'-0" X 8'-0" DRY ERASE MARKER BOARD WITH MAP RAIL,

MOUNT BOTTOM AT 3'-0" A.F.F. REFER TO DETAIL 7/A-580.

WHEN BOARD IS ATTACHED TO A FIRE RATED WALL ADD

FIRE CAULK TO MAINTAIN RATING.

17 1-1/2" DIAMETER GUARDRAIL, REFER TO DETAIL 1/A-450.

18 1-1/2" DIAMETER HANDRAIL. REFER TO DETAIL 2/A-450.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

OFFICE

ELEC

E

F

G

2 3 4 5 6

OFFICE

T.R.

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

8'

7" 3'

6' - 5" 6' - 5" 8' - 0" 12' - 11 5/8"

H

C O

R R

ID

O

R

3' - 4" 65' - 6" 3' - 4" 16' - 0"

J

4'

0" 6'

4"

4'

0" 6'

4"

4'

0" 6'

4"

4'

0" 6'

4"

4'

0" 6'

4"

4'

0" 6'

4"

4'

0" 6'

4"

4'

0" 6'

4"

4'

0"

3'

3'

4"

3'

7"

7'

3"

MATCHLINE -

SEE 1/A-112D

3.5

9'

5"

MATCHLINE -

SEE 1/A-112D

27' - 1" 6' - 4" 19' - 7 5/8" 57' - 4"

3'

4"

1" 3'

4"

9' - 6" 9' - 8" 9' - 4 1/2"9' - 7"

ARMORER

83' - 10"

128A

PRINTER

CAGE STORAGE

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

D

IM

EN

SI

O N

P

LA

N

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-113D

D . H

EN

SL

EY

SCALE: 1/8" = 1'-0"A-110

PARTIAL DIMENSION PLAN1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

OFFICE

ELEC

E

F

G

2 3 4 5 6

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

H

A-301

A-301

C O

R R

ID

O

R

J

121C

121D

121B

121F

129130

132 131

135136

139140

143144

145146

121E

124B

TYP.

5 5

55 2

5 2

5 2

5 2

5 2

MATCHLINE -

SEE 1/A-112N

MATCHLINE -

SEE 1/A-112N

3.5

ARMORER

OFFICE

T.R.

A-551

A-551

A-551

128A

PRINTER A-551

CAGE STORAGE

ARCHITECTURAL LEGEND

INDICATES DOOR NUMBER.

REFER TO DOOR SCHEDULE ON SHEET A-600.

INDICATES WINDOW TYPE. REFER TO SHEET A-510.

INDICATES LOUVER TYPE. REFER TO SHEET A-530.

INDICATES WALL TYPE CONSTRUCTION.

REFER TO SHEET A-540.

INDICATES (1) HOUR RATED WALL. REFER TO LIFE

SAFETY PLANS.

INDICATES SMOKE PARTITION. REFER TO LIFE SAFETY

PLANS.

1FB

SP

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

N O

TE

P

LA

N

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-113N

D . H

EN

SL

EY

SCALE: 1/8" = 1'-0"A-110

PARTIAL NOTE PLAN1

SHEET KEYNOTES

1 SURFACE MOUNTED FIRE EXTINGUISHER BRACKET.

MOUNT BOTTOM AT 27" A.F.F.

2 4'-0" X 8'-0" TACK BOARD, MOUNT BOTTOM AT 3'-0" A.F.F.

REFER TO DETAIL 8/A-580.

3 OPERABLE ACOUSTICAL PANEL PARTITION WITH STC 45

RATING. PROVIDE METAL BLOCKING IN WALL AT JAMB.

REFER TO DETAIL 5/A-560.

4 6" WIDE BY 5" DEEP PRE-FINISHED METAL DOWNSPOUT

WITH CAST IRON DOWNSPOUT BOOT. CONNECT TO

UNDERGROUND STORM DRAINAGE SYSTEM. REFER TO

ELEVATIONS.

5 10' WIDE X 10' HIGH OVERHEAD COILING DOOR. REFER TO

DOOR SCHEDULE.

6 SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH A

10lb. FIRE EXTINGUISHER. (TO BE ONE HOUR RATED

WHEN INSTALLED IN A RATED WALL). REFER TO DETAIL

4/A-580.

7 BAHAMA STYLE HURRICANE SHUTTERS. REFER TO

DETAIL 5/A-510.

8 6'-0" WIDE BY 4'-0" DEEP ENTRANCE CANOPY. REFER TO

DETAILS ON SHEET A-570.

9 8'-4" WIDE X 12'-4" DEEP (INSIDE CLEAR SPACE) WELDED

WIRE FABRIC CAGES WITH (3) 4'-0" W X 2'-0"D X 7'-0"H

SHELVES. REFER TO SHEETS A-710 THROUGH A-713 FOR

DETAILS.

10 6" WIDE BY 5" DEEP PRE-FINISHED METAL DOWNSPOUT

WITH CONCRETE SPLASHBLOCK. REFER TO ELEVATIONS.

11 ROOF ACCESS LADDER.

12 48" X 48" ROOF HATCH ABOVE. REFER TO DETAIL 1/A-570

13 6" DIAMETER 4'-0" TALL CONCRETE FILLED PIPE BOLLARD

(AT EXTERIOR LOCATIONS). REFER TO STRUCTURAL

DRAWINGS FOR DETAILS.

14 6" DIAMETER TALL PIPE BALLARD WITH PLATE MOUNTED

BASE (AT INTERIOR LOCATIONS)

15 SECURED LOCK BOX FOR FIRE DEPARTMENT ACCESS TO

BE PROVIDED AND INSTALLED BY THE CONTRACTOR.

CONTRACTOR TO COORDINATE REQUIREMENTS WITH

THE FIRE DEPARTMENT.

16 4'-0" X 8'-0" DRY ERASE MARKER BOARD WITH MAP RAIL,

MOUNT BOTTOM AT 3'-0" A.F.F. REFER TO DETAIL 7/A-580.

WHEN BOARD IS ATTACHED TO A FIRE RATED WALL ADD

FIRE CAULK TO MAINTAIN RATING.

17 1-1/2" DIAMETER GUARDRAIL, REFER TO DETAIL 1/A-450.

18 1-1/2" DIAMETER HANDRAIL. REFER TO DETAIL 2/A-450.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

A-200

A-200

A-200

A-200

B

C

D

E

F

G

2 3 4 5 6 9 10

H

A-301

A-301

A-301

A-301

J

A

1/2" / 12"

1/2" / 12"

1/2" / 12"

1/2" / 12"

TYP.

TYP.

TYP.

3.5

STRUCTURAL SLOPE

STRUCTURAL SLOPE

STRUCTURAL SLOPE

STRUCTURAL SLOPE

1'

0"

77' - 0"

9'

0"

172' - 0"

34' - 0"

121' - 10" 5'

93' - 2"

A-161

A-161

A-450

A-450

GRAPHIC SCALE: = 1'-0"

16' 08' 32' 48'16'

1/16"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

C O

M

PO

SI

TE

R O

O F

PL

AN

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-130

D . H

EN

SL

EY

SCALE: 1/16" = 1'-0"A-130

COMPOSITE ROOF PLAN1

GENERAL SHEET NOTES

1 REFER TO STRUCTURAL DRAWINGS FOR ROOF FRAMING.

2 REFER TO MECHANICAL AND ELECTRICAL DRAWINGS

FOR ROOF MOUNTED EQUIPMENT.

3 ROOF SLOPES ARE NOMINAL. REFER TO STRUCTURAL

DRAWINGS FOR JOIST BEARING ELEVATIONS.

4 IF MULTIPLE LAYERS OF INSULATION ARE USED, JOINTS

OF SUCCESSIVE LAYERS SHOULD BE OFFSET FROM THE

PREVIOUS LAYER.

5 LIGHTNING PROTECTION SHALL BE PROVIDED BY THE

CONTRACTOR AND FOLLOW THE REQUIREMENTS LISTED

ON THE ELECTRICAL DRAWINGS.

SHEET KEYNOTES

1 2 PLY SBS MODIFIED BITUMEN ROOF SYSTEM

(CONSISTING OF A BASE PLY AND GRANULAR CAP SHEET)

OVER 1/2" GLASS-MAT GYPSUM SHEATHING OVER

POLYISOCYANURATE INSULATION (MIN.(2) LAYERS,

STAGGERED - R-20) OVER METAL ROOF DECK.

2 RIDGE LINE.

3 VENT THRU ROOF. COORDINATE LOCATIONS WITH

PLUMBING DRAWINGS. REFER TO DETAIL 5/A-571.

4 PRE-FINISHED 24" W x 18" H x 11" D METAL CONDUCTOR

BOX AND 6"W X 5"D DOWNSPOUT.

5 16"W X 4"H THRU WALL SCUPPERS. REFER TO DETAIL

4/A-571.

6 TAPERED INSULATION CRICKET. SLOPE 1" PER FOOT.

SADDLE FLASHING TO BE WATERTIGHT IN ACCORDANCE

WITH SMACNA, EQUIPMENT MANUFACTURER, AND

ROOFING MANUFACTURER.

7 48" X 48" ROOF HATCH. REFER TO DETAILS ON SHEET

A-570.

8 6'-0" WIDE BY 4'-0" DEEP ENTRANCE CANOPY. REFER TO

DETAILS ON SHEET A-570.

9 16"W X 4"H THRU WALL SECONDARY SCUPPER.

10 BASE BID: STEEL COLUMNS EXTENDING ABOVE THE ROOF

FOR SUPPORT OF SOLAR PANELS. REFER TO

STRUCTURAL DRAWINGS. REFER TO FLASHING DETAIL

4/A-570.

BID OPTION: REMAINDER OF SUPPORT FRAMING AND

SOLAR PANELS. REFER TO STRUCTURAL AND ELECTRICAL

DRAWINGS.

11 PREFINISHED METAL COPING.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

PC

JJ

M M

M

B

C

D

E

F

G

2 3 4 5 6 9 10

H

J

A

73.5 8

A-141

A-142

A-143

ARCHITECTURAL LEGEND

2'-0"X 2'-0" SUSPENDED ACOUSTICAL CEILING

(KITCHEN GRADE MOISTURE RESISTANT IN KITCHEN

AND RESTROOMS)

SUSPENDED GYPSUM BOARD CEILING (MOISTURE

RESISTANT IN KITCHEN)

EXPOSED CEILING

CONCRETE

4'-0" SURFACE MOUNTED LIGHT FIXTURES

1'-0" X 4'-0" LIGHT FIXTURES

2'-0" X 2'-0" LIGHT FIXTURES

HID FIXTURE

EMERGENCY LIGHTING

EXIT SIGN

AIR TERMINAL: SUPPLY/RETURN/EXHAUST

EMERGENCY EXTERIOR LIGHT

GRAPHIC SCALE: = 1'-0"

16' 08' 32' 48'16'

1/16"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

C O

M

PO

SI

TE

R

EF

LE

C

TE

D

C

EI

LI

N

G P

LA

N

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-140

D . H

EN

SL

EY

SCALE: 1/16" = 1'-0"A-140

COMPOSITE REFLECTED CEILING PLAN1

GENERAL SHEET NOTES

1 REFER TO PARTIAL PLANS A-141 THROUGH A-143.

2 REFER TO MECHANICAL AND ELECTRICAL DRAWINGS

FOR MECHANICAL AND LIGHTING FIXTURES.

3 REFER TO ROOM FINISH SCHEDULE.

4 REFER TO SPECIFICATIONS FOR ACCESS PANEL

REQUIREMENTS IN CEILINGS.

5 ALL OPENINGS FOR SPRINKLER HEADS, MECHANICAL

DIFFUSERS, LIGHT FIXTURES AND HUNG SIGNS SHALL BE

CENTERED IN ACOUSTICAL CEILING TILE PANELS.

6 METAL STUD FRAMING FOR GYPSUM BOARD CEILINGS

SHALL BE SPACED AT 12" O.C.

7 FIELD VERIFY DISTANCE OF PROJECTOR MOUNT WITH

PROJECTOR MANUFACTURER PRIOR TO INSTALLATION.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

C

D

E

6 9 10

100 101 9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

A

9' - 0" 111

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

14' - 0"

9' - 0"

EXP

1 1

EXP

M

AT

C H

LI

N

E

SE

E

1/ A

-1

M

AT

C H

LI

N

E

SE

E

1/ A

-1

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"9' - 0"

ARCHITECTURAL LEGEND

2'-0"X 2'-0" SUSPENDED ACOUSTICAL CEILING

(KITCHEN GRADE MOISTURE RESISTANT IN KITCHEN

AND RESTROOMS)

SUSPENDED GYPSUM BOARD CEILING (MOISTURE

RESISTANT IN KITCHEN)

EXPOSED CEILING

CONCRETE

4'-0" SURFACE MOUNTED LIGHT FIXTURES

1'-0" X 4'-0" LIGHT FIXTURES

2'-0" X 2'-0" LIGHT FIXTURES

HID FIXTURE

EMERGENCY LIGHTING

EXIT SIGN

AIR TERMINAL: SUPPLY/RETURN/EXHAUST

EMERGENCY EXTERIOR LIGHT

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

R

EF

LE

C

TE

D

C

EI

LI

N

G P

LA

N

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-141

D . H

EN

SL

EY

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN1

A-140

SHEET KEYNOTES

1 SOFFIT, REFER TO DETAIL 1/A-560.

2 BULKHEAD, REFER TO DETAIL 2/A-560.

3 BULKHEAD, REFER TO DETAIL 3/A-560.

4 BULKHEAD, REFER TO DETAIL 4/A-560.

5 OPERABLE PARTITION CEILING TRACK. REFER TO DETAIL

5/A-560.

6 3'-0" X 3'-0" ACCESS PANEL.

7 EXPOSED DUCTWORK BELOW CEILING.

8 48" x 48" ROOF HATCH.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

C

D

E

2 3 4 5 6

A

12' - 0"

MATCHLINE -

SEE 1/A-143

MATCHLINE -

SEE 1/A-143

M

AT

C H

LI

N

E

SE

E

1/ A

-1

M

AT

C H

LI

N

E

SE

E

1/ A

-1

3.5

11' - 8"

9' - 0"

EXP

EXP

11' - 8"

ARCHITECTURAL LEGEND

2'-0"X 2'-0" SUSPENDED ACOUSTICAL CEILING

(KITCHEN GRADE MOISTURE RESISTANT IN KITCHEN

AND RESTROOMS)

SUSPENDED GYPSUM BOARD CEILING (MOISTURE

RESISTANT IN KITCHEN)

EXPOSED CEILING

CONCRETE

4'-0" SURFACE MOUNTED LIGHT FIXTURES

1'-0" X 4'-0" LIGHT FIXTURES

2'-0" X 2'-0" LIGHT FIXTURES

HID FIXTURE

EMERGENCY LIGHTING

EXIT SIGN

AIR TERMINAL: SUPPLY/RETURN/EXHAUST

EMERGENCY EXTERIOR LIGHT

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

R

EF

LE

C

TE

D

C

EI

LI

N

G P

LA

N

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-142

D . H

EN

SL

EY

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN1

A-140

SHEET KEYNOTES

1 SOFFIT, REFER TO DETAIL 1/A-560.

2 BULKHEAD, REFER TO DETAIL 2/A-560.

3 BULKHEAD, REFER TO DETAIL 3/A-560.

4 BULKHEAD, REFER TO DETAIL 4/A-560.

5 OPERABLE PARTITION CEILING TRACK. REFER TO DETAIL

5/A-560.

6 3'-0" X 3'-0" ACCESS PANEL.

7 EXPOSED DUCTWORK BELOW CEILING.

8 48" x 48" ROOF HATCH.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

E

F

G

2 3 4 5 6

EXP

EXP

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

H

J

MATCHLINE -

SEE 1/A-142

MATCHLINE -

SEE 1/A-142

3.5

ARCHITECTURAL LEGEND

2'-0"X 2'-0" SUSPENDED ACOUSTICAL CEILING

(KITCHEN GRADE MOISTURE RESISTANT IN KITCHEN

AND RESTROOMS)

SUSPENDED GYPSUM BOARD CEILING (MOISTURE

RESISTANT IN KITCHEN)

EXPOSED CEILING

CONCRETE

4'-0" SURFACE MOUNTED LIGHT FIXTURES

1'-0" X 4'-0" LIGHT FIXTURES

2'-0" X 2'-0" LIGHT FIXTURES

HID FIXTURE

EMERGENCY LIGHTING

EXIT SIGN

AIR TERMINAL: SUPPLY/RETURN/EXHAUST

EMERGENCY EXTERIOR LIGHT

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

R

EF

LE

C

TE

D

C

EI

LI

N

G P

LA

N

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-143

D . H

EN

SL

EY

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN1

A-140

SHEET KEYNOTES

1 SOFFIT, REFER TO DETAIL 1/A-560.

2 BULKHEAD, REFER TO DETAIL 2/A-560.

3 BULKHEAD, REFER TO DETAIL 3/A-560.

4 BULKHEAD, REFER TO DETAIL 4/A-560.

5 OPERABLE PARTITION CEILING TRACK. REFER TO DETAIL

5/A-560.

6 3'-0" X 3'-0" ACCESS PANEL.

7 EXPOSED DUCTWORK BELOW CEILING.

8 48" x 48" ROOF HATCH.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

A-161

A-161 9'

2"

1/ 2"

1/ 2"

1/ 2"

8'

2"

1/ 2"

5'

/1

1/ 2"

9"

1/ 2"

1/ 2"

1"

1/ 2"

/2

1/ 2"

7'

/2

1/ 2"

9'

3"

1/2"

11' - 10"

1/2"

11' - 9"

1/2"

9' - 3"

1/2"

12' - 0"

1/2"

12' - 0"

1/2"

12' - 0"

1/2"

12' - 0"

1/2"

12' - 0"

9' - 4 1/2" 1/2"

12' - 0" 1/2"

11' - 11" 1/2"

12' - 0" 1/2" 12' - 0"

1/2" 12' - 0"

1/2" 7' - 5 1/2"

11' - 6 1/2" 1/2"

12' - 0" 1/2"

12' - 0" 1/2" 12' - 0"

1/2" 12' - 0"

1/2" 12' - 0"

1/2" 12' - 0"

1/2" 9' - 4"

1/2" 9' - 3"

1/2" 9' - 4"

1/2" 12' - 0"

1/2" 12' - 0"

1/2" 12' - 0"

1/2" 12' - 0"

1/2" 11' - 11 1/2"

8'

4"

1/ 2"

/2

1/ 2"

/2

1/ 2"

/2

1/ 2"

/2

1/ 2"

/2

1/ 2"

/2

1/ 2"

/2

1/ 2"

/2

1/ 2"

1/ 2"

1/ 2"

7'

1/

2"

8'

1/

2" 1/

2" 12

1/ 2"

8'

1/ 2"

1/ 2"

1/ 2"

1/ 2"

1/ 2"

1/ 2"

1/ 2"

1/ 2"

9'

9" 1/

2"

1/ 2" 1/

2"

1/ 2"

1/ 2"

6'

6"

1/ 2"

1/ 2"

8'

4" 1/

2"

1/

2" 8'

0"

1/ 2"

1/ 2"

12' - 0" 1/2" 12' - 0"

1/2" 9' - 11"

1/2"

12' - 0"

1/2"

12' - 0"

1/2"

12' - 0"

1/2"

12' - 0"

1/2"

12' - 0"1' - 5"

1/2"

12' - 0"

1/2"

12' - 0"

1/2"

12' - 0"

1/2"

12' - 0"

1/2"

12' - 0"

5' -7

'-9

GRAPHIC SCALE: = 1'-0"

16' 08' 32' 48'16'

1/16"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

C O

M

PO

SI

TE

P R

EC

AS

T

PA

N

EL

F

LO

O R

P

LA

N

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-160

D . H

EN

SL

EY

SCALE: 1/16" = 1'-0"A-160

COMPOSITE PRECAST PANEL FLOOR PLAN1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

LEVEL 1

100' - 0"

T.O. PRECAST

127' - 1"

A

3'

2" 3"

5'

0" 6"

4'

1" 3"

3'

9" 3"

1'

3" 3"

9'

3"

PRECAST CONCRETE

REVEAL, PAINT EXT-15.

PRECAST CONCRETE

REVEAL, PAINT EXT-15.

PRECAST CONCRETE

REVEAL, PAINT EXT-15.

PRECAST CONCRETE

REVEAL, PAINT EXT-15.

3'

4"

DOOR. REFER TO PRECAST

FLOOR PLAN A-160

WINDOW. REFER TO

PRECAST FLOOR PLAN

A-160.

SECONDARY OVERFLOW

SCUPPER OPENING.

PRIMARY SCUPPER

OPENING.

EX

T-

EX

T-

T.O. ROOF

PANEL JOINT

LEVEL 1

100' - 0"

CDE

T.O. PRECAST

127' - 1"

3'

2" 3"

5'

0" 6"

3'

9" 3"

1'

3" 3"

9'

3"

PRECAST CONCRETE

REVEAL, PAINT EXT-15.

PRECAST CONCRETE

REVEAL, PAINT EXT-15.

PRECAST CONCRETE

REVEAL, PAINT EXT-15.

PRECAST CONCRETE

REVEAL, PAINT EXT-15.

DOOR. REFER TO PRECAST

FLOOR PLAN A-160

EX

T-

EX

T-

LOUVER REFER TO BUILDING ELEVATIONS

A-203 AND A-204 FOR LOCATIONS.SECONDARY OVERFLOW

SCUPPER OPENING.

PRIMARY SCUPPER

OPENING.

1' - 4"

4" 4"

1' - 4"

T.O. ROOF

PANEL JOINT

3" 4'

1"

3'

4"

4' 02' 8' 12'4'

GRAPHIC SCALE: = 1'-0"1/4"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PR

EC

AS

T

PA

N

EL

E

LE

VA

TI

O

N S

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-161

D . H

EN

SL

EY

SCALE: 1/4" = 1'-0"A-161

TYPICAL PRECAST PANEL ELEVATION 11

SCALE: 1/4" = 1'-0"A-161

TYPICAL PRECAST PANEL ELEVATION 22

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

INFILL BETWEEN PANELS WITH

SPRAY FOAM INSULATION.

LEAVE ROOM AT EACH END FOR

BACKER ROD AND CAULK.

OUTSIDE

OUTSIDE

1/ 2"

1/2"

1/2

INFILL BETWEEN PANELS WITH

SPRAY FOAM INSULATION.

LEAVE ROOM AT EACH END FOR

BACKER ROD AND CAULK.

1/4" 1/2" 1/4"

1/2"

1/ 2"

VA

R

IE

S

1/ 2"

4"

1/2" 3 1/2"

1/ 2"

INFILL BETWEEN PANELS WITH

SPRAY FOAM INSULATION.

LEAVE ROOM AT EACH END FOR

BACKER ROD AND CAULK.

BUTYL SELF-ADHESIVE

MEMBRANE FLASHING

(USED AS AN AIR

INFILTRATION BARRIER).

CONTRACTOR TO INSTALL

WITH FLEXIBILITY @ JOINT.

EXTEND MEMBRANE

FLASHING FROM FLOOR TO

DECK.

BACKER ROD

AND CAULK

BACKER ROD

AND FIRE CAULK

BUTYL SELF-ADHESIVE

MEMBRANE FLASHING

(USED AS AN AIR

INFILTRATION BARRIER).

CONTRACTOR TO INSTALL

WITH FLEXIBILITY @ JOINT.

EXTEND MEMBRANE

FLASHING FROM FLOOR TO

DECK.

WALL BASE

BACKER ROD

AND CAULK

EXPANSION JOINT

GRAPHIC SCALE: = 1'-0"

1' 0 2'

1 1/2"

6" 1'

GRAPHIC SCALE: = 1'-0"

GRAPHIC SCALE: = 1'-0"

1' 06" 2' 3'1'

1"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PR

EC

AS

T

PA

N

EL

D

ET

AI

LS

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-162

D . H

EN

SL

EY

SCALE: 1" = 1'-0"A-162

OUTSIDE CORNER DETAIL1

SCALE: 1" = 1'-0"A-162

PANEL JOINT DETAIL2

SCALE: 1" = 1'-0"A-162

HORIZONTAL REVEAL3

SCALE: 1" = 1'-0"A-162

CHAMFER DETAIL4

SCALE: 1 1/2" = 1'-0"A-162

TYPICAL CAULK DETAIL5

SCALE: 1 1/2" = 1'-0"A-162

WALL BASE DETAIL6

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

ASSEMBLY HALL

MECH114

CHAIR STORAGE

KITCHEN

STORAGE

SCULLERY

JAN

CLOSET

DRINK CLOSET

CLASSROOM

CLASSROOM

CORRIDOR

CLASSROOM

CLASSROOM

MAIN T.R.

CORRIDOR

CORRIDOR

JAN

MEN'S

RESTROOM

WOMEN'S

RESTROOM

I09

I06I08

I07

E03

E08

I10

I05 I13

I11 I12

I16

I14

E04

E07 E01

I03 I02

I04

I01

M01

M02

M02

E02

M04

M02

M04

M04

M04M02

M02

M04

CLASSROOM

CLASSROOM

VEST.

I15

M02

M01

M01

E02

I05

I16 M

AT

C

H

LI

N E

SE

E A-

M

AT

C H

LI

N

E

SE

E

A-

M06

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

S

IG

N

AG

E

PL

AN

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

E.

R

ED

M

O N

K.

J

O N

ES

W . K

IR

KP

AT

R

IC

K

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-181

D . H

EN

SL

EY

SCALE: 1/8" = 1'-0"

PARTIAL SIGNAGE PLAN

GENERAL SHEET NOTES

1 REFER TO A-180 SERIES FOR SIGNAGE PLAN.

2 ROOM NUMBERS AND TEXT OF ALL SIGNS SHALL BE

VERIFIED AND COORDINATED WITH CONTRACTING

OFFICER REPRESENTATIVE.

3 SIGNAGE IS BASED ON 2/90 SIGN SYSTEMS TO ESTABLISH

COLOR, PATTERN, AND FINISH ONLY, AND IS NOT

INTENDED TO LIMIT SELECTION FROM OTHER

MANUFACTURERS. WHEN ALTERNATE SELECTIONS ARE

SUBMITTED, SUBMITTAL SHALL INCLUDE MATERIALS

LISTED FOR COMPARISON.

4 VERIFY LOCATIONS AND GRAPHICS OF EVACUATION

SIGNAGE WITH FIRE MARSHAL.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

W R K

KC

J

E W

R

W

2Q R

R

_P la ns _V ol 3-

MECHANICAL

ELECTRICAL

E05E06

E04

I17

M02

M02

M03

M03 M03

M03

M04

I13

I16

M05

ARMORER

I05

M

AT

C H

LI

N

E

SE

E

A-

M

AT

C

H

LI

N E

SE

E A-

MATCHLINE -

SEE A-183

MATCHLINE -

SEE A-183

CAGE STORAGE

ARMS VAULT

M04

M07

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

S

IG

N

AG

E

PL

AN

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

E.

R

ED

M

O N

K.

J

O N

ES

W . K

IR

KP

AT

R

IC

K

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-182

D . H

EN

SL

EY

SCALE: 1/8" = 1'-0"

PARTIAL SIGNAGE PLAN

GENERAL SHEET NOTES

1 REFER TO A-180 SERIES FOR SIGNAGE PLAN.

2 ROOM NUMBERS AND TEXT OF ALL SIGNS SHALL BE

VERIFIED AND COORDINATED WITH CONTRACTING

OFFICER REPRESENTATIVE.

3 SIGNAGE IS BASED ON 2/90 SIGN SYSTEMS TO ESTABLISH

COLOR, PATTERN, AND FINISH ONLY, AND IS NOT

INTENDED TO LIMIT SELECTION FROM OTHER

MANUFACTURERS. WHEN ALTERNATE SELECTIONS ARE

SUBMITTED, SUBMITTAL SHALL INCLUDE MATERIALS

LISTED FOR COMPARISON.

4 VERIFY LOCATIONS AND GRAPHICS OF EVACUATION

SIGNAGE WITH FIRE MARSHAL.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

W R K

KC

J

E W

R

W

2Q R

R

_P la ns _V ol 3-

E04

E04

E04

I38 I37

I36 I35

I34 I33

I32 I31

I30 I29

I28 I27

I26 I25

I24

I22 I21

I23

I19

I20

E04

I18

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE 137

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE132

OFFICE

OFFICE

ELEC

T.R.

CORRIDOR

M02

M02 M02

M02

M02

M03M03 M03

M03 M03 M03

M04

M04

M04

M04 M04

I17

OFFICE

MATCHLINE -

SEE A-182

MATCHLINE -

SEE A-182

CAGE STORAGE

M01

M01 E09

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

KEYPLAN

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

PA

R

TI

AL

S

IG

N

AG

E

PL

AN

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

E.

R

ED

M

O N

K.

J

O N

ES

W . K

IR

KP

AT

R

IC

K

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-183

D . H

EN

SL

EY

SCALE: 1/8" = 1'-0"

PARTIAL SIGNAGE PLAN

GENERAL SHEET NOTES

1 REFER TO A-180 SERIES FOR SIGNAGE PLAN.

2 ROOM NUMBERS AND TEXT OF ALL SIGNS SHALL BE

VERIFIED AND COORDINATED WITH CONTRACTING

OFFICER REPRESENTATIVE.

3 SIGNAGE IS BASED ON 2/90 SIGN SYSTEMS TO ESTABLISH

COLOR, PATTERN, AND FINISH ONLY, AND IS NOT

INTENDED TO LIMIT SELECTION FROM OTHER

MANUFACTURERS. WHEN ALTERNATE SELECTIONS ARE

SUBMITTED, SUBMITTAL SHALL INCLUDE MATERIALS

LISTED FOR COMPARISON.

4 VERIFY LOCATIONS AND GRAPHICS OF EVACUATION

SIGNAGE WITH FIRE MARSHAL.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

W R K

KC

J

E W

R

W

2Q R

R

_P la ns _V ol 3-

123456910

A-301

A-301

T.O. PRECAST

127' - 1"

A-201

A-201

2 3.58

LEVEL 1

100' - 0"

B C D E F G H

A-301

A-301

T.O. PRECAST

127' - 1"

JA

A-203

A-203

LEVEL 1

100' - 0"

1 2 3 4 5 6 9 10

A-301

A-301

T.O. PRECAST

127' - 1"

A-202

A-202

23.5 8

LEVEL 1

100' - 0"

BCDEFGH

A-301

A-301

T.O. PRECAST

127' - 1"

J A A-204

A-204

GRAPHIC SCALE: = 1'-0"

16' 08' 32' 48'16'

1/16"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

C O

M

PO

SI

TE

B U

IL

D

IN

G

E

LE

VA

TI

O N

S

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-200

D . H

EN

SL

EY

SCALE: 1/16" = 1'-0"A-200

NORTH ELEVATION1

SCALE: 1/16" = 1'-0"A-200

EAST ELEVATION2

SCALE: 1/16" = 1'-0"A-200

SOUTH ELEVATION3

SCALE: 1/16" = 1'-0"A-200

WEST ELEVATION4

GENERAL SHEET NOTES

1 REFER TO STRUCTURAL DRAWINGS FOR CONCRETE

SLAB AND TOP OF MASONRY ELEVATIONS.

2 REFER TO MECHANICAL AND ELECTRICAL DRAWINGS

3 REFER TO SHEET A-610 FOR EXTERIOR FINISH KEY.

4 PROVIDE BACKER ROD AND SEALANT AT JOINTS

BETWEEN DISSIMILAR MATERIALS (MINIMUM 3/4")

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023

K

ER D

.A

M N

B

A M

M

W

2Q R

R

_P la ns _V ol 3-

INDICATES LOUVER TYPE. REFER TO SHEET A-530

100' - 0"

ROOF

125' - 5"

A-310

A-310

T.O. PRECAST

127' - 1"

TYP.

TYP.

TYP.

TYP.

LEVEL 1

100' - 0"

123456

A-301

A-301

T.O. PRECAST

127' - 1"

3.5

TYP.

04'8' 16' 24'8'

GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

SHEET ID

PR

O

JE

C

T N

O . 8

, P 2#

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IT

TA

L

EN

LA

R G

ED

B

U

IL

D

IN

G E

LE

VA

TI

O

N S

U .S

. A R

M Y

R

ES

ER

VE

C

EN

TE

R

O

PE

R

AT

IO

N

S

BU

IL

D

IN

G

FO

R

T

BU

C H

AN

AN

, P U

ER

TO

R

IC

O

M . B

AR

N

ET

T

K.

R

IG

G

S

A.

M

C C

O Y

O C

TO

B

ER

7, LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U I S

VI

LL

E, K

EN

TU

C

KY

A-201

D . H

EN

SL

EY

LEGEND

SHEET KEYNOTES

1 PRE-FINISHED METAL COPING.

2 PRE-FINISHED ALUMINUM WINDOW WITH 1" INSULATED

LAMINATED GLASS, REFER TO SHEET A-510 FOR DETAILS.

3 INSULATED HOLLOW METAL DOOR AND FRAME. REFER

TO SHEET A-600.

4 PRE-FINISHED METAL LOUVER, REFER TO SHEET A-530

AND MECHANICAL DRAWINGS.

5 BAHAMA STYLE HURRICANE SHUTTERS. REFER TO

DETAIL 5/A-510.

6 FINISH GRADE, REFER TO CIVIL DRAWINGS.

7 PRE-FINISHED 6"W X 5"D METAL DOWNSPOUT. PROVIDE A

MINIMUM OF 3 STRAPS BACK TO WALL.

8 PRE-FINISHED 24"W X 18"H X 11"D METAL CONDUCTOR

BOX. REFER TO DETAIL 6/A-571.

9 CAST IRON DOWNSPOUT BOOT. CONNECT TO

UNDERGROUND STORM DRAINAGE SYSTEM AND STORM

SEWER.

10 EXTERIOR LIGHT, REFER TO ELECTRICAL DRAWINGS.

11 PRECAST INSULATED CONCRETE PANELS.(R-10)

12 10' WIDE X 10' HIGH OVERHEAD COILING DOOR. REFER TO

DOOR SCHEDULE.

13 6'-0" WIDE BY 4'-0" DEEP ENTRANCE CANOPY. REFER TO

DETAILS ON SHEET A-570.

14 3" PRECAST CONCRETE REVEAL. REFER TO DETAIL

3/A-162.

15 6" PRECAST CONCRETE REVEAL. REFER TO DETAIL

3/A-162.

16 CONCRETE SPLASHBLOCK.

17 6" DIAMETER 4'-0" TALL CONCRETE FILLED PIPE BOLLARD

(AT EXTERIOR LOCATIONS)

18…