W912QR24R0009_Plans_Vol3-0000.pdf
PDF 11 MB Posted
- Solicitation number
- W912QR24R0009
About this file
This file describes a federal solicitation and related plans volume for a construction project. The solicitation number is W912QR24R0009 from the US Army Corps of Engineers Louisville District for construction services at Fort Buchanan in Puerto Rico. The 11MB plans volume PDF provides additional details on the project scope and requirements. Responses to the solicitation are due on an unspecified date. The construction services sought relate to work at Fort Buchanan and include details on products, services, and pricing in the plans volume file.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers®
SHEET ID
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PROJECT NO. 89301, P2# 481867
PR
O
JE
C
T N
O . 8
, P 2#
N
L
J
G
E
C
A
P
M
K
H
F
D
B
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20
LOUISVILLE DISTRICT
ISSUE DATE: OCTOBER 27, 2023
CONTRACT NO.: -
SOLICITATION NO.: -
CERTIFIED FINAL SUBMITTAL
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
G-001
C O
VE
R
S H
EE
T
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
LO
U
IS
VI
LL
E D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
M .B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, D .H
EN
SL
EY
FORT BUCHANAN, PUERTO RICO
U.S. ARMY RESERVE CENTER OPERATIONS BUILDING
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
K
ER D
.A
M N
B
A M
M
10/27/2023
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/202310/27/2023
10/27/2023
10/27/2023
10/27/2023
10/27/23
VOLUME 3 OF 6
W
2Q R
R
_P la ns _V ol 3-
22 November 2023
W912QR24R0009
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
SHEET ID
P R
O J E
C T
N O
P
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
D R
A W
IN
G
L
IS
T
U .S
A
R M
Y R
E S
E R
V E
C E
N T
E R
O P
E R
A T
IO
N
S B
U
IL
D
IN
G
F O
R T
B U
C H
A N
A N
P
U E
R T
O R
IC
O
M B
A R
N E
T T
K R
IG
G
S
A M
C C
O Y
O C
T O
B E
R
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
G-002
D H
E N
S L E
Y
SHEET LIST
SHEET NUMBER SHEET NAME
M-713 MECHANICAL CONTROLS
ELECTRICAL
E-001 ELECTRICAL LEGEND
E-002 ELECTRICAL GENERAL NOTES & ABBREVIATIONS
EL111 PARTIAL LIGHTING PLAN
EL112 PARTIAL LIGHTING PLAN
EL113 PARTIAL LIGHTING PLAN
EL601 LIGHTING DIAGRAMS
EL701 LIGHTING SCHEDULES
EP111 PARTIAL POWER PLAN
EP112 PARTIAL POWER PLAN
EP113 PARTIAL POWER PLAN
EP130 BID OPTION 0014 - ROOF PV ARRAY PLAN
EP151 PARTIAL HVAC POWER PLAN
EP152 PARTIAL HVAC POWER PLAN
EP153 PARTIAL HVAC POWER PLAN
EP410 ENLARGED POWER PLANS
EP501 ELECTRICAL DETAILS
EP601 POWER ONE LINE DIAGRAM
EP701 PANEL SCHEDULES
EP702 PANEL SCHEDULES
EP703 PANEL SCHEDULES
EP704 PANEL SCHEDULES
EP705 PANEL SCHEDULES
EY111 PARTIAL SPECIAL SYSTEMS PLAN
EY112 PARTIAL SPECIAL SYSTEMS PLAN
EY113 PARTIAL SPECIAL SYSTEMS PLAN
EY501 SPECIAL SYSTEMS DETAILS
EG130 LIGHTNING PROTECTION PLAN
EG131 BID OPTION 0014 - LIGHTNING PROTECTION PLAN
EG501 LIGHTNING PROTECTION DETAILS
EG502 GROUNDING DETAILS
EG601 GROUNDING ONE LINE DIAGRAM
TELECOMMUNICATIONS
T-001 COMMUNICATIONS LEGENDS
T-002 COMMUNICATIONS GENERAL NOTES & ABBREVIATIONS
T-111 PARTIAL COMMUNICATIONS PLAN
T-112 PARTIAL COMMUNICATIONS PLAN
T-113 PARTIAL COMMUNICATIONS PLAN
T-410 ENLARGED COMMUNICATIONS PLANS
T-501 COMMUNICATIONS DETAILS
T-502 COMMUNICATIONS DETAILS
T-601 COMMUNICATION DIAGRAMS
T-602 COMMUNICATION ROOM 147 ELEVATION DIAGRAM
T-603 COMMUNICATION ROOM 126 ELEVATION DIAGRAM
SHEET LIST
SHEET NUMBER SHEET NAME
INTERIORS
I-001 FF&E LEGEND
I-110 COMPOSITE FURNITURE PLAN
I-111 PARTIAL FURNITURE PLAN
I-112 PARTIAL FURNITURE PLAN
I-113 PARTIAL FURNITURE PLAN
LIFE SAFETY
LS001 ABBREVIATIONS, LEGEND AND GENERAL NOTES
LS100 CODE COMPLIANCE SITE PLAN
LS110 LEVEL 1 LIFE SAFETY PLAN - COMPOSITE
FIRE PROTECTION
FP001 ABBREVIATIONS, LEGEND AND GENERAL NOTES
FP110 LEVEL 1 FIRE PROTECTION PLAN - COMPOSITE
FP501 FIRE PROTECTION DETAILS
FP502 FIRE PROTECTION DETAILS
FIRE ALARM
FA001 ABBREVIATIONS, LEGEND AND GENERAL NOTES
FA110 LEVEL 1 FIRE ALARM PLAN - COMPOSITE
FA501 FIRE ALARM DETAILS
FA502 FIRE ALARM DETAILS
PLUMBING
P-001 ABBREVIATIONS, LEGEND AND GENERAL NOTES
PP101 PARTIAL UNDERGROUND PLAN
PP102 PARTIAL UNDERGROUND PLAN
PP111 PARTIAL SANITARY PLAN
PP112 PARTIAL SANITARY PLAN
PP113 PARTIAL WATER PLAN
PP114 PARTIAL WATER PLAN
PP115 PARTIAL WATER PLAN
P-401 ENLARGED PLANS
P-402 ENLARGED PLANS
P-403 ENLARGED PLANS
P-404 ENLARGED PLANS
P-405 ENLARGED PLANS
P-406 ENLARGED PLANS
P-501 DETAILS
P-502 DETAILS
P-503 DETAILS
P-504 DETAILS
P-601 SCHEDULES
P-900 RISER DIAGRAMS
P-901 RISER DIAGRAMS
P-902 RISER DIAGRAMS
P-910 RISER DIAGRAMS
P-911 RISER DIAGRAMS
P-912 RISER DIAGRAMS
MECHANICAL
M-001 ABBREVIATIONS, LEGEND AND GENERAL NOTES
MH111 PARTIAL FLOOR PLAN - HVAC
MH112 PARTIAL FLOOR PLAN - HVAC
MH113 PARTIAL FLOOR PLAN - HVAC
MP111 PARTIAL FLOOR PLAN - PIPING
MP112 PARTIAL FLOOR PLAN - PIPING
MP113 PARTIAL FLOOR PLAN - PIPING
M-301 SECTIONS
M-411 ENLARGED PLAN - HVAC
M-412 ENLARGED PLAN - PIPING
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-503 MECHANICAL DETAILS
M-504 MECHANICAL DETAILS
M-505 MECHANICAL DETAILS
M-506 MECHANICAL DETAILS
M-507 MECHANICAL DETAILS
M-550 AIR RISER DIAGRAM
M-551 AIR RISER DIAGRAM
M-552 AIR RISER DIAGRAM
M-553 CHILLED WATER PIPING DIAGRAM
M-601 MECHANICAL SCHEDULES
M-602 MECHANICAL SCHEDULES
M-603 MECHANICAL SCHEDULES
M-701 MECHANICAL CONTROLS
M-702 MECHANICAL CONTROLS
M-703 MECHANICAL CONTROLS
M-704 MECHANICAL CONTROLS
M-705 MECHANICAL CONTROLS
M-706 MECHANICAL CONTROLS
M-707 MECHANICAL CONTROLS
M-708 MECHANICAL CONTROLS
M-709 MECHANICAL CONTROLS
M-710 MECHANICAL CONTROLS
M-711 MECHANICAL CONTROLS
M-712 MECHANICAL CONTROLS
SHEET LIST
SHEET NUMBER SHEET NAME
S-362 FRAMING SECTIONS
S-363 FRAMING SECTIONS
S-364 FRAMING SECTIONS
S-365 FRAMING SECTIONS
S-366 BID OPTION - SOLAR PANEL SUPPORT FRAMING SECTIONS
S-401 ENLARGED RAMP FOUNDATION/SLAB PLAN
S-402 RAMP SECTIONS
S-411 ENLARGED VAULT ROOF SLAB FRAMING PLAN
S-412 VAULT SECTIONS AND DETAILS
S-413 VAULT SECTIONS
S-501 TYPICAL FOUNDATION DETAILS
S-502 TYPICAL FOUNDATION DETAILS
S-503 PRECAST WALL PANEL DETAILS
S-511 TYPICAL FRAMING DETAILS
S-601 SCHEDULES
S-602 SPECIAL JOIST LOADING DIAGRAM
ARCHITECTURE
A-001 SYMBOL LEGEND
A-110 COMPOSITE FLOOR PLAN
A-111D PARTIAL DIMENSION PLAN
A-111N PARTIAL NOTE PLAN
A-112D PARTIAL DIMENSION PLAN
A-112N PARTIAL NOTE PLAN
A-113D PARTIAL DIMENSION PLAN
A-113N PARTIAL NOTE PLAN
A-130 COMPOSITE ROOF PLAN
A-140 COMPOSITE REFLECTED CEILING PLAN
A-141 PARTIAL REFLECTED CEILING PLAN
A-142 PARTIAL REFLECTED CEILING PLAN
A-143 PARTIAL REFLECTED CEILING PLAN
A-160 COMPOSITE PRECAST PANEL FLOOR PLAN
A-161 PRECAST PANEL ELEVATIONS
A-162 PRECAST PANEL DETAILS
A-181 PARTIAL SIGNAGE PLAN
A-182 PARTIAL SIGNAGE PLAN
A-183 PARTIAL SIGNAGE PLAN
A-200 COMPOSITE BUILDING ELEVATIONS
A-201 ENLARGED BUILDING ELEVATIONS
A-202 ENLARGED BUILDING ELEVATIONS
A-203 ENLARGED BUILDING ELEVATIONS
A-204 ENLARGED BUILDING ELEVATIONS
A-301 BUILDING SECTIONS
A-310 WALL SECTIONS
A-311 WALL SECTIONS
A-400 ENLARGED RESTROOM PLAN
A-401 RESTROOM DETAILS
A-402 TYPICAL RESTROOM MOUNTING HEIGHTS
A-410 RESTROOM ELEVATIONS
A-450 RAILING DETAILS
A-461 PARTIAL FINISH PLAN
A-462 PARTIAL FINISH PLAN
A-463 PARTIAL FINISH PLAN
A-500 DOOR AND FRAME TYPES AND ABA MANEUVERING
CLEARANCES
A-501 DOOR DETAILS
A-502 DOOR DETAILS
A-510 WINDOW TYPES & DETAILS
A-530 LOUVER TYPES AND DETAILS
A-540 WALL TYPES
A-541 WALL DETAILS
A-542 WALL DETAILS
A-550 COLUMN DETAILS
A-551 COLUMN DETAILS
A-560 CEILING DETAILS
A-570 ROOF DETAILS
A-571 ROOF DETAILS
A-580 MISCELLANEOUS DETAILS
A-600 DOOR SCHEDULE
A-610 FINISH SCHEDULE AND EXTERIOR FINISH KEY
A-611 FINISH KEYS & NOTES
A-620 SIGNAGE SCHEDULE
A-621 SIGNAGE DETAILS
A-700 ENLARGED VAULT DIMENSION PLAN
A-701 ENLARGED VAULT NOTED PLAN
A-710 ENLARGED CAGE PLANS
A-711 CAGE ELEVATIONS
A-712 CAGE SECTIONS AND DETAILS
A-713 CAGE DETAILS
A-800 ENLARGED KITCHEN PLAN
A-801 KITCHEN SCHEDULE
A-900 AIR BARRIER FLOOR PLAN
A-901 AIR BARRIER WALL SECTION
SHEET LIST
SHEET NUMBER SHEET NAME
GENERAL
G-001 COVER SHEET
G-002 DRAWING LIST
G-201 LOCATION AND VICINITY MAP
G-202 PROJECT AERIAL
CIVIL
V-101 OVERALL SITE SURVEY
V-111 SITE SURVEY
V-112 SITE SURVEY
B-101 OVERALL BORING PLAN
B-111 BORING PLAN
B-112 BORING PLAN
B-201 BORING LOGS
B-202 BORING LOGS
C-001 CIVIL LEGEND AND ABBREVATIONS
C-002 CIVIL GENERAL NOTES
CD101 OVERALL DEMOLITION PLAN
CD111 DEMOLITION PLAN
CD112 DEMOLITION PLAN
CG101 OVERALL GRADING AND DRAINAGE PLAN
CG111 GRADING AND DRAINAGE PLAN
CG112 GRADING AND DRAINAGE PLAN
CG201 STORM SEWER PROFILES & SCHEDULE
CG501 DRAINAGE DETAILS
CG502 DRAINAGE DETAILS
CG503 DRAINAGE DETAILS
CG701 OVERALL SEDIMENT AND EROSION CONTROL PLAN
CG711 SEDIMENT AND EROSION CONTROL PLAN
CG712 SEDIMENT AND EROSION CONTROL PLAN
CG801 SEDIMENT AND EROSION CONTROL NOTES
CG802 SEDIMENT AND EROSION CONTROL DETAILS
CG803 SEDIMENT AND EROSION CONTROL DETAILS
CG804 SEDIMENT AND EROSION CONTROL DETAILS
CG805 SEDIMENT AND EROSION CONTROL DETAILS
CG806 SEDIMENT AND EROSION CONTROL DETAILS
CS101 OVERALL SITE LAYOUT
CS111 SITE LAYOUT
CS112 SITE LAYOUT
CS401 JOINT LAYOUT PLAN
CS501 PAVEMENT DETAILS
CS502 PAVEMENT DETAILS
CS503 DESIGNATED SMOKING AREA SIGNAGE
CU101 OVERALL UTILITY PLAN
CU111 UTILITY PLAN
CU112 UTILITY PLAN
CU201 SANITARY SEWER PROFILES & SCHEDULE
CU501 SANITARY SEWER DETAILS
CU502 SANITARY SEWER DETAILS
CU511 WATER DETAILS
CU512 WATER DETAILS
LP101 OVERALL LANDSCAPE PLAN
LP111 LANDSCAPE PLAN
LP112 LANDSCAPE PLAN
ELECTRICAL
ES100 EXISTING ELECTRICAL SITE PLAN
ES101 ELECTRICAL SITE PLAN
ES501 SITE ELECTRICAL DETAILS
ES502 BID OPTION - SITE ELECTRICAL DETAILS
ES503 SITE ELECTRICAL DETAILS
TELECOMMUNICATIONS
TS101 COMMUNICATION SITE PLAN
STRUCTURAL
S-001 GENERAL STRUCTURAL NOTES AND DESIGN CRITERIA
S-002 GENERAL STRUCTURAL NOTES, DESIGN CRITERIA AND
ABBREVIATIONS
S-003 COMPONENTS AND CLADDING WIND LOAD DIAGRAM
S-111 PARTIAL FOUNDATION/FLOOR SLAB PLAN
S-112 PARTIAL FOUNDATION/FLOOR SLAB PLAN
S-113 PARTIAL FOUNDATION/FLOOR SLAB PLAN
S-114 SLAB ON GRADE CONTROL JOINT PLAN
S-131 PARTIAL ROOF FRAMING PLAN
S-132 PARTIAL ROOF FRAMING PLAN
S-133 PARTIAL ROOF FRAMING PLAN
S-141 BID OPTION - SOLAR PANEL SUPPORT FRAMING PLAN
S-200 PRECAST CONCRETE WALL ELEVATIONS KEY PLAN
S-211 CONCRETE WALL ELEVATIONS
S-212 CONCRETE WALL ELEVATIONS
S-213 CONCRETE WALL ELEVATIONS
S-251 OPERABLE PARTITION SUPPORT FRAMING ELEVATION AND
SECTION
S-301 FOUNDATION SECTIONS
S-302 FOUNDATION SECTIONS
S-361 FRAMING SECTIONS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
K
ER D
.A
M N
B
A M
M
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
W
2Q R
R
_P la ns _V ol 3-
AREA OF DETAIL
NUMBER OF SHEET ON WHICH DETAIL IS DRAWN
DETAIL IDENTIFICATION NUMBER
* SYMBOL WHERE DETAIL IS TAKEN:
A-401
SCALE AT WHICH SECTION OR DETAIL IS DRAWN
NUMBERS OF SHEET WHERE SECTION OR DETAIL IS
CUT
* SUBTITLE FOR SECTION/DETAIL DRAWING:
SCALE AT WHICH ELEVATION IS DRAWN
NUMBERS OF SHEET WHERE ELEVATION IS SHOWN
* SYMBOL WHERE ELEVATION IS TAKEN
SUBTITLE FOR ELEVATION DRAWING:
A-200
ELEVATION IDENTIFICATION NUMBER
GRANULAR/GRAVEL FILL
EARTH
CONCRETE
RIGID INSULATION
BLANKET, BATT, OR LOOSE FILL INSULATION
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
GRAPHIC SCALE: = 1'-0"
1" 0 2" 3"1"
12"
½"
GRAPHIC SCALE: = 1'-0"
GRAPHIC SCALE: = 1'-0"
32' 016' 64' 96'32'
1/32"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
SY
M
BO
L
LE
G
EN
D
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-001
D . H
EN
SL
EY
REFERENCE SYMBOLOGY
SCALE: 1 1/2" = 1'-0"A-001
SECTION OR DETAIL2
SCALE: 1/8" = 1'-0"A-001
ELEVATION3
MATERIALS LEGEND
NORTH ARROW FOR PROJECT
INDICATES THE SCALE THE
DRAWING ON THE SHEET IS
DRAWN AT.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
A-200
A-200
A-200
A-200
172' - 0" 77' - 0"
249' - 0"
34' - 0" 121' - 10" 93' - 2"
5'
B
C
D
E
F
G
H
A-301
A-301
A-301
A-301
A-111N
A-111D
A-113N
A-113D
J
A
A-112D
A-112N
DRINK CLOSET
SCULLERY
ELEC
ELECTRICAL
CORRIDOR
ASSEMBLY HALL
OFFICE
OFFICE
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
MECHANICAL
MAIN T.R.
T.R.
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
WOMEN'S RESTROOM
JAN
MEN'S RESTROOM
CORRIDOR
JAN
KITCHEN
CLOSET
STORAGE
VEST.
CORRIDOR
CORRIDOR
MECH
CHAIR STORAGE
3.5
3.5
CLASSROOM
CLASSROOM
ARMS VAULT
ARMORER
5'
4"
A-450
A-450
CAGE STORAGE
128A
PRINTER
9'
0"
1'
0"
GRAPHIC SCALE: = 1'-0"
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
C O
M
PO
SI
TE
F
LO
O R
P
LA
N
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-110
D . H
EN
SL
EY
SCALE: 1/16" = 1'-0"
COMPOSITE FLOOR PLAN
GENERAL SHEET NOTES
1 REFER TO PARTIAL PLANS A-111 THROUGH A-113 FOR
DIMENSIONS AND NOTES.
2 REFER TO STRUCTURAL DRAWINGS FOR FINISH FLOOR
ELEVATIONS.
3 REFER TO SPECIAL ITEMS KEY FOR WINDOW COVERING.
4 TYPICAL DOORS IN STUD WALLS SHALL BE 4" FROM
NEAREST WALL UNLESS OTHERWISE INDICATED.
5 ALL DIMENSIONS ARE FROM FACE OF PRECAST
CONCRETE PANEL OR METAL STUDS, UNLESS
OTHERWISE NOTED.
6 PROVIDE CONTROL JOINTS IN GYPSUM BOARD. REFER TO
SPECIFICATIONS.
7 PROVIDE CORNER GUARDS AT OUTSIDE CORNERS IN
GYPSUM BOARD WALLS. REFER TO DETAIL 2/A-580.
8 PROVIDE 20 GA. METAL STUDS AND BLOCKING IN AREAS
OF WALL AND CEILING MOUNTED ITEMS (TV'S, MONITORS,
CAMERAS, ETC.) REFER TO ELECTRICAL AND FURNITURE
PLANS.
9 SLOPE FLOORS TO DRAIN WHERE SPECIFICALLY NOTED.
REFER TO STRUCTURAL, MECHANICAL AND PLUMBING
DRAWINGS.
10 CFCI COLLATERAL EQUIPMENT AND CFCI BONA FIDE
NEED EQUIPMENT ITEMS SHALL BE PRICED SEPARATELY.
REFER TO BID SCHEDULES.
ROOM SCHEDULE
NUMBER ROOM NAME SQUARE FOOTAGE
100 VEST. 73 SF
101 CORRIDOR 306 SF
102 CORRIDOR 323 SF
103 CLASSROOM 532 SF
104 CLASSROOM 526 SF
105 CLASSROOM 551 SF
106 CLASSROOM 554 SF
107 ASSEMBLY HALL 3806 SF
108 DRINK CLOSET 24 SF
109 CLOSET 23 SF
110 SCULLERY 163 SF
111 JAN 26 SF
112 KITCHEN 544 SF
113 STORAGE 144 SF
114 CHAIR STORAGE 443 SF
115 CORRIDOR 447 SF
116 JAN 57 SF
117 WOMEN'S RESTROOM 350 SF
118 MEN'S RESTROOM 466 SF
119 CLASSROOM 660 SF
120 CLASSROOM 599 SF
121 CAGE STORAGE 25055 SF
122 ARMORER 124 SF
123 ARMS VAULT 3111 SF
124 MECHANICAL 2300 SF
125 ELECTRICAL 286 SF
126 T.R. 48 SF
127 ELEC 72 SF
128 CORRIDOR 688 SF
128A PRINTER 23 SF
129 OFFICE 120 SF
130 OFFICE 120 SF
131 OFFICE 120 SF
132 OFFICE 120 SF
133 OFFICE 120 SF
134 OFFICE 119 SF
135 OFFICE 120 SF
136 OFFICE 120 SF
137 OFFICE 120 SF
138 OFFICE 119 SF
139 OFFICE 120 SF
140 OFFICE 120 SF
141 OFFICE 120 SF
142 OFFICE 119 SF
143 OFFICE 120 SF
144 OFFICE 120 SF
145 OFFICE 120 SF
146 OFFICE 120 SF
147 MAIN T.R. 108 SF
148 MECH 95 SF
GROSS SQ. FT. 46,666 SF
NET SQ. FT. 44,611 SF
1/2 SQ. FT (CANOPIES) 36 SF
ALLOWABLE SQ. FT. 53,690 SF
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
DRINK CLOSET
CORRIDOR
ASSEMBLY HALL
B
C
D
E
6 9 10
MEN'S
RESTROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
MAIN T.R.
JAN
10' - 7" 33' - 9" 46' - 4"
3'
7" 7'
3"
5'
4"
4'
9"
5'
4" 5'
5"
0"
8'
6'
7" 5'
4"
6'
0"
CORRIDOR
C O
R R
ID
O
R
VEST.
3' - 4"
23' - 1" 3' - 4"
7' - 4" 46' - 3 7/8"
KITCHEN
SCULLERY
STORAGE
CLOSET
JAN
5'
3"4'
0" 4'
0"
4'
0"
8'
6" 3'
4"
4'
0" 4'
0"
4'
0"
5'
5"6'
4" 5'
9"
3'
4"
1"
3'
4"
4' - 10"3' - 4" 1' - 3"
4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 31' - 7"
A
WOMEN'S
RESTROOM
76' - 5" 3' - 5" 24' - 1"
MECH
0"
7' - 4" 37' - 10" 8' - 5 7/8"
CHAIR STORAGE
A-400
M
AT
C H
LI
N
E
SE
E
1/ A-
2D
M
AT
C H
LI
N
E
SE
E
1/ A-
2D
18' - 9 3/8"
3'
4"
5' - 4"
3'
4"
5' - 4"
5' - 3 7/8"
3'
4"
3'
4"
5' - 4"
CLASSROOM
CLASSROOM
50' - 6"
15' - 5 1/2" 4' - 9" 15' - 5 1/2"
4' - 0" 4' - 0" 4' - 0" 7' - 9"7' - 9"8' - 6"
3' - 4"
15' - 5 1/2" 4' - 9" 15' - 5 1/2"
6' - 0" 5' - 6" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0"
/4
41' - 10" 10' - 6"
11' - 4"
28' - 7" 10' - 6" 10' - 3 3/4"
20' - 1 1/4"26' - 6"
21' - 11" 21' - 11"
20' - 0"20' - 0"7'
0"
2'
7"
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
D
IM
EN
SI
O N
P
LA
N
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-111D
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"A-110
PARTIAL DIMENSION PLAN1
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
SCULLERY
CORRIDOR
B
C
D
E
6 9 10
DRINK CLOSET
CORRIDOR
MEN'S
RESTROOM
CORRIDOR
ASSEMBLY HALL
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
MAIN T.R.
JAN
STORAGE
KITCHEN
CLOSET
A-400
A-310
A-310
A-310100
VEST.
CORRIDOR
C O
R R
ID
O
R
A
112A
118 117
107B
107A
WOMEN'S
RESTROOM
CHAIR STORAGE
MECH
A-400
JAN
A-800
7 TYP.
7 TYP.
A A A A A
A
A
A
A
11 11
5 5
6 66
M
AT
C H
LI
N
E
SE
E
1/ A-
2N
M
AT
C H
LI
N
E
SE
E
1/ A-
2N
5 5
5 5
105106
103 104
13 13 13 13
13 13
A-550
A-550
CLASSROOM
CLASSROOM
AA
5 5
A-550
A-550
A-550
A-550
A-550
7 TYP.
7 TYP.
6 1
16 16
16 16
18 18
A-551
A-450
A-450
107C
ARCHITECTURAL LEGEND
INDICATES DOOR NUMBER.
REFER TO DOOR SCHEDULE ON SHEET A-600.
INDICATES WINDOW TYPE. REFER TO SHEET A-510.
INDICATES LOUVER TYPE. REFER TO SHEET A-530.
INDICATES WALL TYPE CONSTRUCTION.
REFER TO SHEET A-540.
INDICATES (1) HOUR RATED WALL. REFER TO LIFE
SAFETY PLANS.
INDICATES SMOKE PARTITION. REFER TO LIFE SAFETY
PLANS.
1FB
SP
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
N O
TE
P
LA
N
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-111N
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"A-110
PARTIAL NOTE PLAN1
SHEET KEYNOTES
1 SURFACE MOUNTED FIRE EXTINGUISHER BRACKET.
MOUNT BOTTOM AT 27" A.F.F.
2 4'-0" X 8'-0" TACK BOARD, MOUNT BOTTOM AT 3'-0" A.F.F.
REFER TO DETAIL 8/A-580.
3 OPERABLE ACOUSTICAL PANEL PARTITION WITH STC 45
RATING. PROVIDE METAL BLOCKING IN WALL AT JAMB.
REFER TO DETAIL 5/A-560.
4 6" WIDE BY 5" DEEP PRE-FINISHED METAL DOWNSPOUT
WITH CAST IRON DOWNSPOUT BOOT. CONNECT TO
UNDERGROUND STORM DRAINAGE SYSTEM. REFER TO
ELEVATIONS.
5 10' WIDE X 10' HIGH OVERHEAD COILING DOOR. REFER TO
DOOR SCHEDULE.
6 SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH A
10lb. FIRE EXTINGUISHER. (TO BE ONE HOUR RATED
WHEN INSTALLED IN A RATED WALL). REFER TO DETAIL
4/A-580.
7 BAHAMA STYLE HURRICANE SHUTTERS. REFER TO
DETAIL 5/A-510.
8 6'-0" WIDE BY 4'-0" DEEP ENTRANCE CANOPY. REFER TO
DETAILS ON SHEET A-570.
9 8'-4" WIDE X 12'-4" DEEP (INSIDE CLEAR SPACE) WELDED
WIRE FABRIC CAGES WITH (3) 4'-0" W X 2'-0"D X 7'-0"H
SHELVES. REFER TO SHEETS A-710 THROUGH A-713 FOR
DETAILS.
10 6" WIDE BY 5" DEEP PRE-FINISHED METAL DOWNSPOUT
WITH CONCRETE SPLASHBLOCK. REFER TO ELEVATIONS.
11 ROOF ACCESS LADDER.
12 48" X 48" ROOF HATCH ABOVE. REFER TO DETAIL 1/A-570
13 6" DIAMETER 4'-0" TALL CONCRETE FILLED PIPE BOLLARD
(AT EXTERIOR LOCATIONS). REFER TO STRUCTURAL
DRAWINGS FOR DETAILS.
14 6" DIAMETER TALL PIPE BALLARD WITH PLATE MOUNTED
BASE (AT INTERIOR LOCATIONS)
15 SECURED LOCK BOX FOR FIRE DEPARTMENT ACCESS TO
BE PROVIDED AND INSTALLED BY THE CONTRACTOR.
CONTRACTOR TO COORDINATE REQUIREMENTS WITH
THE FIRE DEPARTMENT.
16 4'-0" X 8'-0" DRY ERASE MARKER BOARD WITH MAP RAIL,
MOUNT BOTTOM AT 3'-0" A.F.F. REFER TO DETAIL 7/A-580.
WHEN BOARD IS ATTACHED TO A FIRE RATED WALL ADD
FIRE CAULK TO MAINTAIN RATING.
17 1-1/2" DIAMETER GUARDRAIL, REFER TO DETAIL 1/A-450.
18 1-1/2" DIAMETER HANDRAIL. REFER TO DETAIL 2/A-450.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
B
C
D
E
2 3 4 5 6
MECHANICAL
MEN'S
RESTROOM
ELECTRICAL
6'
4"
A
M
AT
C H
LI
N
E
SE
E
1/ A-
1D
MATCHLINE -
SEE 1/A-113D
3.5
7'
3/
8" 7'
0"
10' - 0"
0"
34' - 0"
7'
0"
7' - 0"
19' - 4"
1' - 9" 3' - 4"
19' - 1" 6' - 4"
3' - 6"
ARMORER
33' - 7" 68' - 0" 22' - 8"
M
AT
C H
LI
N
E
SE
E
1/ A-
1D
CAGE STORAGE
14' - 3"
3' - 8"
A-710 2A-710
MATCHLINE -
SEE 1/A-113D
ARMS VAULT
A-700
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
D
IM
EN
SI
O N
P
LA
N
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-112D
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"A-110
PARTIAL DIMENSION PLAN1
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
C
D
E
2 3 4 5 6
MECHANICAL
MEN'S
RESTROOM
A-301
A-301
ELECTRICAL
A
121A
121B
124B
MATCHLINE -
SEE 1/A-113N
MATCHLINE -
SEE 1/A-113N
M
AT
C H
LI
N
E
SE
E
1/ A-
1N
M
AT
C H
LI
N
E
SE
E
1/ A-
1N
3.5
11ABOVE
A-310
A-310
ARMORER
ARMS VAULT
A-550
A-550
A-551
125 124A
1 1
CAGE STORAGE
A-710
A-710
A-701
107C
ARCHITECTURAL LEGEND
INDICATES DOOR NUMBER.
REFER TO DOOR SCHEDULE ON SHEET A-600.
INDICATES WINDOW TYPE. REFER TO SHEET A-510.
INDICATES LOUVER TYPE. REFER TO SHEET A-530.
INDICATES WALL TYPE CONSTRUCTION.
REFER TO SHEET A-540.
INDICATES (1) HOUR RATED WALL. REFER TO LIFE
SAFETY PLANS.
INDICATES SMOKE PARTITION. REFER TO LIFE SAFETY
PLANS.
1FB
SP
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
N O
TE
P
LA
N
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-112N
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"A-110
PARTIAL NOTE PLAN1
SHEET KEYNOTES
1 SURFACE MOUNTED FIRE EXTINGUISHER BRACKET.
MOUNT BOTTOM AT 27" A.F.F.
2 4'-0" X 8'-0" TACK BOARD, MOUNT BOTTOM AT 3'-0" A.F.F.
REFER TO DETAIL 8/A-580.
3 OPERABLE ACOUSTICAL PANEL PARTITION WITH STC 45
RATING. PROVIDE METAL BLOCKING IN WALL AT JAMB.
REFER TO DETAIL 5/A-560.
4 6" WIDE BY 5" DEEP PRE-FINISHED METAL DOWNSPOUT
WITH CAST IRON DOWNSPOUT BOOT. CONNECT TO
UNDERGROUND STORM DRAINAGE SYSTEM. REFER TO
ELEVATIONS.
5 10' WIDE X 10' HIGH OVERHEAD COILING DOOR. REFER TO
DOOR SCHEDULE.
6 SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH A
10lb. FIRE EXTINGUISHER. (TO BE ONE HOUR RATED
WHEN INSTALLED IN A RATED WALL). REFER TO DETAIL
4/A-580.
7 BAHAMA STYLE HURRICANE SHUTTERS. REFER TO
DETAIL 5/A-510.
8 6'-0" WIDE BY 4'-0" DEEP ENTRANCE CANOPY. REFER TO
DETAILS ON SHEET A-570.
9 8'-4" WIDE X 12'-4" DEEP (INSIDE CLEAR SPACE) WELDED
WIRE FABRIC CAGES WITH (3) 4'-0" W X 2'-0"D X 7'-0"H
SHELVES. REFER TO SHEETS A-710 THROUGH A-713 FOR
DETAILS.
10 6" WIDE BY 5" DEEP PRE-FINISHED METAL DOWNSPOUT
WITH CONCRETE SPLASHBLOCK. REFER TO ELEVATIONS.
11 ROOF ACCESS LADDER.
12 48" X 48" ROOF HATCH ABOVE. REFER TO DETAIL 1/A-570
13 6" DIAMETER 4'-0" TALL CONCRETE FILLED PIPE BOLLARD
(AT EXTERIOR LOCATIONS). REFER TO STRUCTURAL
DRAWINGS FOR DETAILS.
14 6" DIAMETER TALL PIPE BALLARD WITH PLATE MOUNTED
BASE (AT INTERIOR LOCATIONS)
15 SECURED LOCK BOX FOR FIRE DEPARTMENT ACCESS TO
BE PROVIDED AND INSTALLED BY THE CONTRACTOR.
CONTRACTOR TO COORDINATE REQUIREMENTS WITH
THE FIRE DEPARTMENT.
16 4'-0" X 8'-0" DRY ERASE MARKER BOARD WITH MAP RAIL,
MOUNT BOTTOM AT 3'-0" A.F.F. REFER TO DETAIL 7/A-580.
WHEN BOARD IS ATTACHED TO A FIRE RATED WALL ADD
FIRE CAULK TO MAINTAIN RATING.
17 1-1/2" DIAMETER GUARDRAIL, REFER TO DETAIL 1/A-450.
18 1-1/2" DIAMETER HANDRAIL. REFER TO DETAIL 2/A-450.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
OFFICE
ELEC
E
F
G
2 3 4 5 6
OFFICE
T.R.
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
8'
7" 3'
6' - 5" 6' - 5" 8' - 0" 12' - 11 5/8"
H
C O
R R
ID
O
R
3' - 4" 65' - 6" 3' - 4" 16' - 0"
J
4'
0" 6'
4"
4'
0" 6'
4"
4'
0" 6'
4"
4'
0" 6'
4"
4'
0" 6'
4"
4'
0" 6'
4"
4'
0" 6'
4"
4'
0" 6'
4"
4'
0"
3'
3'
4"
3'
7"
7'
3"
MATCHLINE -
SEE 1/A-112D
3.5
9'
5"
MATCHLINE -
SEE 1/A-112D
27' - 1" 6' - 4" 19' - 7 5/8" 57' - 4"
3'
4"
1" 3'
4"
9' - 6" 9' - 8" 9' - 4 1/2"9' - 7"
ARMORER
83' - 10"
128A
PRINTER
CAGE STORAGE
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
D
IM
EN
SI
O N
P
LA
N
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-113D
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"A-110
PARTIAL DIMENSION PLAN1
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
OFFICE
ELEC
E
F
G
2 3 4 5 6
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
H
A-301
A-301
C O
R R
ID
O
R
J
121C
121D
121B
121F
129130
132 131
135136
139140
143144
145146
121E
124B
TYP.
5 5
55 2
5 2
5 2
5 2
5 2
MATCHLINE -
SEE 1/A-112N
MATCHLINE -
SEE 1/A-112N
3.5
ARMORER
OFFICE
T.R.
A-551
A-551
A-551
128A
PRINTER A-551
CAGE STORAGE
ARCHITECTURAL LEGEND
INDICATES DOOR NUMBER.
REFER TO DOOR SCHEDULE ON SHEET A-600.
INDICATES WINDOW TYPE. REFER TO SHEET A-510.
INDICATES LOUVER TYPE. REFER TO SHEET A-530.
INDICATES WALL TYPE CONSTRUCTION.
REFER TO SHEET A-540.
INDICATES (1) HOUR RATED WALL. REFER TO LIFE
SAFETY PLANS.
INDICATES SMOKE PARTITION. REFER TO LIFE SAFETY
PLANS.
1FB
SP
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
N O
TE
P
LA
N
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-113N
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"A-110
PARTIAL NOTE PLAN1
SHEET KEYNOTES
1 SURFACE MOUNTED FIRE EXTINGUISHER BRACKET.
MOUNT BOTTOM AT 27" A.F.F.
2 4'-0" X 8'-0" TACK BOARD, MOUNT BOTTOM AT 3'-0" A.F.F.
REFER TO DETAIL 8/A-580.
3 OPERABLE ACOUSTICAL PANEL PARTITION WITH STC 45
RATING. PROVIDE METAL BLOCKING IN WALL AT JAMB.
REFER TO DETAIL 5/A-560.
4 6" WIDE BY 5" DEEP PRE-FINISHED METAL DOWNSPOUT
WITH CAST IRON DOWNSPOUT BOOT. CONNECT TO
UNDERGROUND STORM DRAINAGE SYSTEM. REFER TO
ELEVATIONS.
5 10' WIDE X 10' HIGH OVERHEAD COILING DOOR. REFER TO
DOOR SCHEDULE.
6 SEMI-RECESSED FIRE EXTINGUISHER CABINET WITH A
10lb. FIRE EXTINGUISHER. (TO BE ONE HOUR RATED
WHEN INSTALLED IN A RATED WALL). REFER TO DETAIL
4/A-580.
7 BAHAMA STYLE HURRICANE SHUTTERS. REFER TO
DETAIL 5/A-510.
8 6'-0" WIDE BY 4'-0" DEEP ENTRANCE CANOPY. REFER TO
DETAILS ON SHEET A-570.
9 8'-4" WIDE X 12'-4" DEEP (INSIDE CLEAR SPACE) WELDED
WIRE FABRIC CAGES WITH (3) 4'-0" W X 2'-0"D X 7'-0"H
SHELVES. REFER TO SHEETS A-710 THROUGH A-713 FOR
DETAILS.
10 6" WIDE BY 5" DEEP PRE-FINISHED METAL DOWNSPOUT
WITH CONCRETE SPLASHBLOCK. REFER TO ELEVATIONS.
11 ROOF ACCESS LADDER.
12 48" X 48" ROOF HATCH ABOVE. REFER TO DETAIL 1/A-570
13 6" DIAMETER 4'-0" TALL CONCRETE FILLED PIPE BOLLARD
(AT EXTERIOR LOCATIONS). REFER TO STRUCTURAL
DRAWINGS FOR DETAILS.
14 6" DIAMETER TALL PIPE BALLARD WITH PLATE MOUNTED
BASE (AT INTERIOR LOCATIONS)
15 SECURED LOCK BOX FOR FIRE DEPARTMENT ACCESS TO
BE PROVIDED AND INSTALLED BY THE CONTRACTOR.
CONTRACTOR TO COORDINATE REQUIREMENTS WITH
THE FIRE DEPARTMENT.
16 4'-0" X 8'-0" DRY ERASE MARKER BOARD WITH MAP RAIL,
MOUNT BOTTOM AT 3'-0" A.F.F. REFER TO DETAIL 7/A-580.
WHEN BOARD IS ATTACHED TO A FIRE RATED WALL ADD
FIRE CAULK TO MAINTAIN RATING.
17 1-1/2" DIAMETER GUARDRAIL, REFER TO DETAIL 1/A-450.
18 1-1/2" DIAMETER HANDRAIL. REFER TO DETAIL 2/A-450.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
A-200
A-200
A-200
A-200
B
C
D
E
F
G
2 3 4 5 6 9 10
H
A-301
A-301
A-301
A-301
J
A
1/2" / 12"
1/2" / 12"
1/2" / 12"
1/2" / 12"
TYP.
TYP.
TYP.
3.5
STRUCTURAL SLOPE
STRUCTURAL SLOPE
STRUCTURAL SLOPE
STRUCTURAL SLOPE
1'
0"
77' - 0"
9'
0"
172' - 0"
34' - 0"
121' - 10" 5'
93' - 2"
A-161
A-161
A-450
A-450
GRAPHIC SCALE: = 1'-0"
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
C O
M
PO
SI
TE
R O
O F
PL
AN
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-130
D . H
EN
SL
EY
SCALE: 1/16" = 1'-0"A-130
COMPOSITE ROOF PLAN1
GENERAL SHEET NOTES
1 REFER TO STRUCTURAL DRAWINGS FOR ROOF FRAMING.
2 REFER TO MECHANICAL AND ELECTRICAL DRAWINGS
FOR ROOF MOUNTED EQUIPMENT.
3 ROOF SLOPES ARE NOMINAL. REFER TO STRUCTURAL
DRAWINGS FOR JOIST BEARING ELEVATIONS.
4 IF MULTIPLE LAYERS OF INSULATION ARE USED, JOINTS
OF SUCCESSIVE LAYERS SHOULD BE OFFSET FROM THE
PREVIOUS LAYER.
5 LIGHTNING PROTECTION SHALL BE PROVIDED BY THE
CONTRACTOR AND FOLLOW THE REQUIREMENTS LISTED
ON THE ELECTRICAL DRAWINGS.
SHEET KEYNOTES
1 2 PLY SBS MODIFIED BITUMEN ROOF SYSTEM
(CONSISTING OF A BASE PLY AND GRANULAR CAP SHEET)
OVER 1/2" GLASS-MAT GYPSUM SHEATHING OVER
POLYISOCYANURATE INSULATION (MIN.(2) LAYERS,
STAGGERED - R-20) OVER METAL ROOF DECK.
2 RIDGE LINE.
3 VENT THRU ROOF. COORDINATE LOCATIONS WITH
PLUMBING DRAWINGS. REFER TO DETAIL 5/A-571.
4 PRE-FINISHED 24" W x 18" H x 11" D METAL CONDUCTOR
BOX AND 6"W X 5"D DOWNSPOUT.
5 16"W X 4"H THRU WALL SCUPPERS. REFER TO DETAIL
4/A-571.
6 TAPERED INSULATION CRICKET. SLOPE 1" PER FOOT.
SADDLE FLASHING TO BE WATERTIGHT IN ACCORDANCE
WITH SMACNA, EQUIPMENT MANUFACTURER, AND
ROOFING MANUFACTURER.
7 48" X 48" ROOF HATCH. REFER TO DETAILS ON SHEET
A-570.
8 6'-0" WIDE BY 4'-0" DEEP ENTRANCE CANOPY. REFER TO
DETAILS ON SHEET A-570.
9 16"W X 4"H THRU WALL SECONDARY SCUPPER.
10 BASE BID: STEEL COLUMNS EXTENDING ABOVE THE ROOF
FOR SUPPORT OF SOLAR PANELS. REFER TO
STRUCTURAL DRAWINGS. REFER TO FLASHING DETAIL
4/A-570.
BID OPTION: REMAINDER OF SUPPORT FRAMING AND
SOLAR PANELS. REFER TO STRUCTURAL AND ELECTRICAL
DRAWINGS.
11 PREFINISHED METAL COPING.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
PC
JJ
M M
M
B
C
D
E
F
G
2 3 4 5 6 9 10
H
J
A
73.5 8
A-141
A-142
A-143
ARCHITECTURAL LEGEND
2'-0"X 2'-0" SUSPENDED ACOUSTICAL CEILING
(KITCHEN GRADE MOISTURE RESISTANT IN KITCHEN
AND RESTROOMS)
SUSPENDED GYPSUM BOARD CEILING (MOISTURE
RESISTANT IN KITCHEN)
EXPOSED CEILING
CONCRETE
4'-0" SURFACE MOUNTED LIGHT FIXTURES
1'-0" X 4'-0" LIGHT FIXTURES
2'-0" X 2'-0" LIGHT FIXTURES
HID FIXTURE
EMERGENCY LIGHTING
EXIT SIGN
AIR TERMINAL: SUPPLY/RETURN/EXHAUST
EMERGENCY EXTERIOR LIGHT
GRAPHIC SCALE: = 1'-0"
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
C O
M
PO
SI
TE
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-140
D . H
EN
SL
EY
SCALE: 1/16" = 1'-0"A-140
COMPOSITE REFLECTED CEILING PLAN1
GENERAL SHEET NOTES
1 REFER TO PARTIAL PLANS A-141 THROUGH A-143.
2 REFER TO MECHANICAL AND ELECTRICAL DRAWINGS
FOR MECHANICAL AND LIGHTING FIXTURES.
3 REFER TO ROOM FINISH SCHEDULE.
4 REFER TO SPECIFICATIONS FOR ACCESS PANEL
REQUIREMENTS IN CEILINGS.
5 ALL OPENINGS FOR SPRINKLER HEADS, MECHANICAL
DIFFUSERS, LIGHT FIXTURES AND HUNG SIGNS SHALL BE
CENTERED IN ACOUSTICAL CEILING TILE PANELS.
6 METAL STUD FRAMING FOR GYPSUM BOARD CEILINGS
SHALL BE SPACED AT 12" O.C.
7 FIELD VERIFY DISTANCE OF PROJECTOR MOUNT WITH
PROJECTOR MANUFACTURER PRIOR TO INSTALLATION.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
C
D
E
6 9 10
100 101 9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
A
9' - 0" 111
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
14' - 0"
9' - 0"
EXP
1 1
EXP
M
AT
C H
LI
N
E
SE
E
1/ A
-1
M
AT
C H
LI
N
E
SE
E
1/ A
-1
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"9' - 0"
ARCHITECTURAL LEGEND
2'-0"X 2'-0" SUSPENDED ACOUSTICAL CEILING
(KITCHEN GRADE MOISTURE RESISTANT IN KITCHEN
AND RESTROOMS)
SUSPENDED GYPSUM BOARD CEILING (MOISTURE
RESISTANT IN KITCHEN)
EXPOSED CEILING
CONCRETE
4'-0" SURFACE MOUNTED LIGHT FIXTURES
1'-0" X 4'-0" LIGHT FIXTURES
2'-0" X 2'-0" LIGHT FIXTURES
HID FIXTURE
EMERGENCY LIGHTING
EXIT SIGN
AIR TERMINAL: SUPPLY/RETURN/EXHAUST
EMERGENCY EXTERIOR LIGHT
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-141
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN1
A-140
SHEET KEYNOTES
1 SOFFIT, REFER TO DETAIL 1/A-560.
2 BULKHEAD, REFER TO DETAIL 2/A-560.
3 BULKHEAD, REFER TO DETAIL 3/A-560.
4 BULKHEAD, REFER TO DETAIL 4/A-560.
5 OPERABLE PARTITION CEILING TRACK. REFER TO DETAIL
5/A-560.
6 3'-0" X 3'-0" ACCESS PANEL.
7 EXPOSED DUCTWORK BELOW CEILING.
8 48" x 48" ROOF HATCH.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
C
D
E
2 3 4 5 6
A
12' - 0"
MATCHLINE -
SEE 1/A-143
MATCHLINE -
SEE 1/A-143
M
AT
C H
LI
N
E
SE
E
1/ A
-1
M
AT
C H
LI
N
E
SE
E
1/ A
-1
3.5
11' - 8"
9' - 0"
EXP
EXP
11' - 8"
ARCHITECTURAL LEGEND
2'-0"X 2'-0" SUSPENDED ACOUSTICAL CEILING
(KITCHEN GRADE MOISTURE RESISTANT IN KITCHEN
AND RESTROOMS)
SUSPENDED GYPSUM BOARD CEILING (MOISTURE
RESISTANT IN KITCHEN)
EXPOSED CEILING
CONCRETE
4'-0" SURFACE MOUNTED LIGHT FIXTURES
1'-0" X 4'-0" LIGHT FIXTURES
2'-0" X 2'-0" LIGHT FIXTURES
HID FIXTURE
EMERGENCY LIGHTING
EXIT SIGN
AIR TERMINAL: SUPPLY/RETURN/EXHAUST
EMERGENCY EXTERIOR LIGHT
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-142
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN1
A-140
SHEET KEYNOTES
1 SOFFIT, REFER TO DETAIL 1/A-560.
2 BULKHEAD, REFER TO DETAIL 2/A-560.
3 BULKHEAD, REFER TO DETAIL 3/A-560.
4 BULKHEAD, REFER TO DETAIL 4/A-560.
5 OPERABLE PARTITION CEILING TRACK. REFER TO DETAIL
5/A-560.
6 3'-0" X 3'-0" ACCESS PANEL.
7 EXPOSED DUCTWORK BELOW CEILING.
8 48" x 48" ROOF HATCH.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
E
F
G
2 3 4 5 6
EXP
EXP
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
H
J
MATCHLINE -
SEE 1/A-142
MATCHLINE -
SEE 1/A-142
3.5
ARCHITECTURAL LEGEND
2'-0"X 2'-0" SUSPENDED ACOUSTICAL CEILING
(KITCHEN GRADE MOISTURE RESISTANT IN KITCHEN
AND RESTROOMS)
SUSPENDED GYPSUM BOARD CEILING (MOISTURE
RESISTANT IN KITCHEN)
EXPOSED CEILING
CONCRETE
4'-0" SURFACE MOUNTED LIGHT FIXTURES
1'-0" X 4'-0" LIGHT FIXTURES
2'-0" X 2'-0" LIGHT FIXTURES
HID FIXTURE
EMERGENCY LIGHTING
EXIT SIGN
AIR TERMINAL: SUPPLY/RETURN/EXHAUST
EMERGENCY EXTERIOR LIGHT
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-143
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN1
A-140
SHEET KEYNOTES
1 SOFFIT, REFER TO DETAIL 1/A-560.
2 BULKHEAD, REFER TO DETAIL 2/A-560.
3 BULKHEAD, REFER TO DETAIL 3/A-560.
4 BULKHEAD, REFER TO DETAIL 4/A-560.
5 OPERABLE PARTITION CEILING TRACK. REFER TO DETAIL
5/A-560.
6 3'-0" X 3'-0" ACCESS PANEL.
7 EXPOSED DUCTWORK BELOW CEILING.
8 48" x 48" ROOF HATCH.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
A-161
A-161 9'
2"
1/ 2"
1/ 2"
1/ 2"
8'
2"
1/ 2"
5'
/1
1/ 2"
9"
1/ 2"
1/ 2"
1"
1/ 2"
/2
1/ 2"
7'
/2
1/ 2"
9'
3"
1/2"
11' - 10"
1/2"
11' - 9"
1/2"
9' - 3"
1/2"
12' - 0"
1/2"
12' - 0"
1/2"
12' - 0"
1/2"
12' - 0"
1/2"
12' - 0"
9' - 4 1/2" 1/2"
12' - 0" 1/2"
11' - 11" 1/2"
12' - 0" 1/2" 12' - 0"
1/2" 12' - 0"
1/2" 7' - 5 1/2"
11' - 6 1/2" 1/2"
12' - 0" 1/2"
12' - 0" 1/2" 12' - 0"
1/2" 12' - 0"
1/2" 12' - 0"
1/2" 12' - 0"
1/2" 9' - 4"
1/2" 9' - 3"
1/2" 9' - 4"
1/2" 12' - 0"
1/2" 12' - 0"
1/2" 12' - 0"
1/2" 12' - 0"
1/2" 11' - 11 1/2"
8'
4"
1/ 2"
/2
1/ 2"
/2
1/ 2"
/2
1/ 2"
/2
1/ 2"
/2
1/ 2"
/2
1/ 2"
/2
1/ 2"
/2
1/ 2"
1/ 2"
1/ 2"
7'
1/
2"
8'
1/
2" 1/
2" 12
1/ 2"
8'
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
9'
9" 1/
2"
1/ 2" 1/
2"
1/ 2"
1/ 2"
6'
6"
1/ 2"
1/ 2"
8'
4" 1/
2"
1/
2" 8'
0"
1/ 2"
1/ 2"
12' - 0" 1/2" 12' - 0"
1/2" 9' - 11"
1/2"
12' - 0"
1/2"
12' - 0"
1/2"
12' - 0"
1/2"
12' - 0"
1/2"
12' - 0"1' - 5"
1/2"
12' - 0"
1/2"
12' - 0"
1/2"
12' - 0"
1/2"
12' - 0"
1/2"
12' - 0"
5' -7
'-9
GRAPHIC SCALE: = 1'-0"
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
C O
M
PO
SI
TE
P R
EC
AS
T
PA
N
EL
F
LO
O R
P
LA
N
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-160
D . H
EN
SL
EY
SCALE: 1/16" = 1'-0"A-160
COMPOSITE PRECAST PANEL FLOOR PLAN1
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
LEVEL 1
100' - 0"
T.O. PRECAST
127' - 1"
A
3'
2" 3"
5'
0" 6"
4'
1" 3"
3'
9" 3"
1'
3" 3"
9'
3"
PRECAST CONCRETE
REVEAL, PAINT EXT-15.
PRECAST CONCRETE
REVEAL, PAINT EXT-15.
PRECAST CONCRETE
REVEAL, PAINT EXT-15.
PRECAST CONCRETE
REVEAL, PAINT EXT-15.
3'
4"
DOOR. REFER TO PRECAST
FLOOR PLAN A-160
WINDOW. REFER TO
PRECAST FLOOR PLAN
A-160.
SECONDARY OVERFLOW
SCUPPER OPENING.
PRIMARY SCUPPER
OPENING.
EX
T-
EX
T-
T.O. ROOF
PANEL JOINT
LEVEL 1
100' - 0"
CDE
T.O. PRECAST
127' - 1"
3'
2" 3"
5'
0" 6"
3'
9" 3"
1'
3" 3"
9'
3"
PRECAST CONCRETE
REVEAL, PAINT EXT-15.
PRECAST CONCRETE
REVEAL, PAINT EXT-15.
PRECAST CONCRETE
REVEAL, PAINT EXT-15.
PRECAST CONCRETE
REVEAL, PAINT EXT-15.
DOOR. REFER TO PRECAST
FLOOR PLAN A-160
EX
T-
EX
T-
LOUVER REFER TO BUILDING ELEVATIONS
A-203 AND A-204 FOR LOCATIONS.SECONDARY OVERFLOW
SCUPPER OPENING.
PRIMARY SCUPPER
OPENING.
1' - 4"
4" 4"
1' - 4"
T.O. ROOF
PANEL JOINT
3" 4'
1"
3'
4"
4' 02' 8' 12'4'
GRAPHIC SCALE: = 1'-0"1/4"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PR
EC
AS
T
PA
N
EL
E
LE
VA
TI
O
N S
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-161
D . H
EN
SL
EY
SCALE: 1/4" = 1'-0"A-161
TYPICAL PRECAST PANEL ELEVATION 11
SCALE: 1/4" = 1'-0"A-161
TYPICAL PRECAST PANEL ELEVATION 22
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
INFILL BETWEEN PANELS WITH
SPRAY FOAM INSULATION.
LEAVE ROOM AT EACH END FOR
BACKER ROD AND CAULK.
OUTSIDE
OUTSIDE
1/ 2"
1/2"
1/2
INFILL BETWEEN PANELS WITH
SPRAY FOAM INSULATION.
LEAVE ROOM AT EACH END FOR
BACKER ROD AND CAULK.
1/4" 1/2" 1/4"
1/2"
1/ 2"
VA
R
IE
S
1/ 2"
4"
1/2" 3 1/2"
1/ 2"
INFILL BETWEEN PANELS WITH
SPRAY FOAM INSULATION.
LEAVE ROOM AT EACH END FOR
BACKER ROD AND CAULK.
BUTYL SELF-ADHESIVE
MEMBRANE FLASHING
(USED AS AN AIR
INFILTRATION BARRIER).
CONTRACTOR TO INSTALL
WITH FLEXIBILITY @ JOINT.
EXTEND MEMBRANE
FLASHING FROM FLOOR TO
DECK.
BACKER ROD
AND CAULK
BACKER ROD
AND FIRE CAULK
BUTYL SELF-ADHESIVE
MEMBRANE FLASHING
(USED AS AN AIR
INFILTRATION BARRIER).
CONTRACTOR TO INSTALL
WITH FLEXIBILITY @ JOINT.
EXTEND MEMBRANE
FLASHING FROM FLOOR TO
DECK.
WALL BASE
BACKER ROD
AND CAULK
EXPANSION JOINT
GRAPHIC SCALE: = 1'-0"
1' 0 2'
1 1/2"
6" 1'
GRAPHIC SCALE: = 1'-0"
GRAPHIC SCALE: = 1'-0"
1' 06" 2' 3'1'
1"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PR
EC
AS
T
PA
N
EL
D
ET
AI
LS
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-162
D . H
EN
SL
EY
SCALE: 1" = 1'-0"A-162
OUTSIDE CORNER DETAIL1
SCALE: 1" = 1'-0"A-162
PANEL JOINT DETAIL2
SCALE: 1" = 1'-0"A-162
HORIZONTAL REVEAL3
SCALE: 1" = 1'-0"A-162
CHAMFER DETAIL4
SCALE: 1 1/2" = 1'-0"A-162
TYPICAL CAULK DETAIL5
SCALE: 1 1/2" = 1'-0"A-162
WALL BASE DETAIL6
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
ASSEMBLY HALL
MECH114
CHAIR STORAGE
KITCHEN
STORAGE
SCULLERY
JAN
CLOSET
DRINK CLOSET
CLASSROOM
CLASSROOM
CORRIDOR
CLASSROOM
CLASSROOM
MAIN T.R.
CORRIDOR
CORRIDOR
JAN
MEN'S
RESTROOM
WOMEN'S
RESTROOM
I09
I06I08
I07
E03
E08
I10
I05 I13
I11 I12
I16
I14
E04
E07 E01
I03 I02
I04
I01
M01
M02
M02
E02
M04
M02
M04
M04
M04M02
M02
M04
CLASSROOM
CLASSROOM
VEST.
I15
M02
M01
M01
E02
I05
I16 M
AT
C
H
LI
N E
SE
E A-
M
AT
C H
LI
N
E
SE
E
A-
M06
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
S
IG
N
AG
E
PL
AN
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
E.
R
ED
M
O N
K.
J
O N
ES
W . K
IR
KP
AT
R
IC
K
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-181
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"
PARTIAL SIGNAGE PLAN
GENERAL SHEET NOTES
1 REFER TO A-180 SERIES FOR SIGNAGE PLAN.
2 ROOM NUMBERS AND TEXT OF ALL SIGNS SHALL BE
VERIFIED AND COORDINATED WITH CONTRACTING
OFFICER REPRESENTATIVE.
3 SIGNAGE IS BASED ON 2/90 SIGN SYSTEMS TO ESTABLISH
COLOR, PATTERN, AND FINISH ONLY, AND IS NOT
INTENDED TO LIMIT SELECTION FROM OTHER
MANUFACTURERS. WHEN ALTERNATE SELECTIONS ARE
SUBMITTED, SUBMITTAL SHALL INCLUDE MATERIALS
LISTED FOR COMPARISON.
4 VERIFY LOCATIONS AND GRAPHICS OF EVACUATION
SIGNAGE WITH FIRE MARSHAL.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
W R K
KC
J
E W
R
W
2Q R
R
_P la ns _V ol 3-
MECHANICAL
ELECTRICAL
E05E06
E04
I17
M02
M02
M03
M03 M03
M03
M04
I13
I16
M05
ARMORER
I05
M
AT
C H
LI
N
E
SE
E
A-
M
AT
C
H
LI
N E
SE
E A-
MATCHLINE -
SEE A-183
MATCHLINE -
SEE A-183
CAGE STORAGE
ARMS VAULT
M04
M07
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
S
IG
N
AG
E
PL
AN
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
E.
R
ED
M
O N
K.
J
O N
ES
W . K
IR
KP
AT
R
IC
K
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-182
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"
PARTIAL SIGNAGE PLAN
GENERAL SHEET NOTES
1 REFER TO A-180 SERIES FOR SIGNAGE PLAN.
2 ROOM NUMBERS AND TEXT OF ALL SIGNS SHALL BE
VERIFIED AND COORDINATED WITH CONTRACTING
OFFICER REPRESENTATIVE.
3 SIGNAGE IS BASED ON 2/90 SIGN SYSTEMS TO ESTABLISH
COLOR, PATTERN, AND FINISH ONLY, AND IS NOT
INTENDED TO LIMIT SELECTION FROM OTHER
MANUFACTURERS. WHEN ALTERNATE SELECTIONS ARE
SUBMITTED, SUBMITTAL SHALL INCLUDE MATERIALS
LISTED FOR COMPARISON.
4 VERIFY LOCATIONS AND GRAPHICS OF EVACUATION
SIGNAGE WITH FIRE MARSHAL.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
W R K
KC
J
E W
R
W
2Q R
R
_P la ns _V ol 3-
E04
E04
E04
I38 I37
I36 I35
I34 I33
I32 I31
I30 I29
I28 I27
I26 I25
I24
I22 I21
I23
I19
I20
E04
I18
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE 137
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE132
OFFICE
OFFICE
ELEC
T.R.
CORRIDOR
M02
M02 M02
M02
M02
M03M03 M03
M03 M03 M03
M04
M04
M04
M04 M04
I17
OFFICE
MATCHLINE -
SEE A-182
MATCHLINE -
SEE A-182
CAGE STORAGE
M01
M01 E09
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
S
IG
N
AG
E
PL
AN
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
E.
R
ED
M
O N
K.
J
O N
ES
W . K
IR
KP
AT
R
IC
K
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-183
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"
PARTIAL SIGNAGE PLAN
GENERAL SHEET NOTES
1 REFER TO A-180 SERIES FOR SIGNAGE PLAN.
2 ROOM NUMBERS AND TEXT OF ALL SIGNS SHALL BE
VERIFIED AND COORDINATED WITH CONTRACTING
OFFICER REPRESENTATIVE.
3 SIGNAGE IS BASED ON 2/90 SIGN SYSTEMS TO ESTABLISH
COLOR, PATTERN, AND FINISH ONLY, AND IS NOT
INTENDED TO LIMIT SELECTION FROM OTHER
MANUFACTURERS. WHEN ALTERNATE SELECTIONS ARE
SUBMITTED, SUBMITTAL SHALL INCLUDE MATERIALS
LISTED FOR COMPARISON.
4 VERIFY LOCATIONS AND GRAPHICS OF EVACUATION
SIGNAGE WITH FIRE MARSHAL.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
W R K
KC
J
E W
R
W
2Q R
R
_P la ns _V ol 3-
123456910
A-301
A-301
T.O. PRECAST
127' - 1"
A-201
A-201
2 3.58
LEVEL 1
100' - 0"
B C D E F G H
A-301
A-301
T.O. PRECAST
127' - 1"
JA
A-203
A-203
LEVEL 1
100' - 0"
1 2 3 4 5 6 9 10
A-301
A-301
T.O. PRECAST
127' - 1"
A-202
A-202
23.5 8
LEVEL 1
100' - 0"
BCDEFGH
A-301
A-301
T.O. PRECAST
127' - 1"
J A A-204
A-204
GRAPHIC SCALE: = 1'-0"
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
C O
M
PO
SI
TE
B U
IL
D
IN
G
E
LE
VA
TI
O N
S
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-200
D . H
EN
SL
EY
SCALE: 1/16" = 1'-0"A-200
NORTH ELEVATION1
SCALE: 1/16" = 1'-0"A-200
EAST ELEVATION2
SCALE: 1/16" = 1'-0"A-200
SOUTH ELEVATION3
SCALE: 1/16" = 1'-0"A-200
WEST ELEVATION4
GENERAL SHEET NOTES
1 REFER TO STRUCTURAL DRAWINGS FOR CONCRETE
SLAB AND TOP OF MASONRY ELEVATIONS.
2 REFER TO MECHANICAL AND ELECTRICAL DRAWINGS
3 REFER TO SHEET A-610 FOR EXTERIOR FINISH KEY.
4 PROVIDE BACKER ROD AND SEALANT AT JOINTS
BETWEEN DISSIMILAR MATERIALS (MINIMUM 3/4")
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
K
ER D
.A
M N
B
A M
M
W
2Q R
R
_P la ns _V ol 3-
INDICATES LOUVER TYPE. REFER TO SHEET A-530
100' - 0"
ROOF
125' - 5"
A-310
A-310
T.O. PRECAST
127' - 1"
TYP.
TYP.
TYP.
TYP.
LEVEL 1
100' - 0"
123456
A-301
A-301
T.O. PRECAST
127' - 1"
3.5
TYP.
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
EN
LA
R G
ED
B
U
IL
D
IN
G E
LE
VA
TI
O
N S
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
M . B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
A-201
D . H
EN
SL
EY
LEGEND
SHEET KEYNOTES
1 PRE-FINISHED METAL COPING.
2 PRE-FINISHED ALUMINUM WINDOW WITH 1" INSULATED
LAMINATED GLASS, REFER TO SHEET A-510 FOR DETAILS.
3 INSULATED HOLLOW METAL DOOR AND FRAME. REFER
TO SHEET A-600.
4 PRE-FINISHED METAL LOUVER, REFER TO SHEET A-530
AND MECHANICAL DRAWINGS.
5 BAHAMA STYLE HURRICANE SHUTTERS. REFER TO
DETAIL 5/A-510.
6 FINISH GRADE, REFER TO CIVIL DRAWINGS.
7 PRE-FINISHED 6"W X 5"D METAL DOWNSPOUT. PROVIDE A
MINIMUM OF 3 STRAPS BACK TO WALL.
8 PRE-FINISHED 24"W X 18"H X 11"D METAL CONDUCTOR
BOX. REFER TO DETAIL 6/A-571.
9 CAST IRON DOWNSPOUT BOOT. CONNECT TO
UNDERGROUND STORM DRAINAGE SYSTEM AND STORM
SEWER.
10 EXTERIOR LIGHT, REFER TO ELECTRICAL DRAWINGS.
11 PRECAST INSULATED CONCRETE PANELS.(R-10)
12 10' WIDE X 10' HIGH OVERHEAD COILING DOOR. REFER TO
DOOR SCHEDULE.
13 6'-0" WIDE BY 4'-0" DEEP ENTRANCE CANOPY. REFER TO
DETAILS ON SHEET A-570.
14 3" PRECAST CONCRETE REVEAL. REFER TO DETAIL
3/A-162.
15 6" PRECAST CONCRETE REVEAL. REFER TO DETAIL
3/A-162.
16 CONCRETE SPLASHBLOCK.
17 6" DIAMETER 4'-0" TALL CONCRETE FILLED PIPE BOLLARD
(AT EXTERIOR LOCATIONS)
18…