This file describes a federal solicitation document and related opportunity. The solicitation number is W912QR24R0009 for construction services at USARC Ft. Buchanan Puerto Rico issued by the Department of the Army Corps of Engineers Engineering District Louisville. The solicitation seeks construction services for an unspecified project at the U.S. Army Reserve Center in Ft. Buchanan, Puerto Rico. The file attached is Plans Volume 2, containing 12MB of project drawings and specifications. The response due date and award timing are not provided in this high-level description.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers®
SHEET ID
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PROJECT NO. 89301, P2# 481867
PR
O
JE
C
T N
O . 8
, P 2#
N
L
J
G
E
C
A
P
M
K
H
F
D
B
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20
LOUISVILLE DISTRICT
ISSUE DATE: OCTOBER 27, 2023
CONTRACT NO.: -
SOLICITATION NO.: -
CERTIFIED FINAL SUBMITTAL
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
G-001
C O
VE
R
S H
EE
T
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
LO
U
IS
VI
LL
E D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
M .B
AR
N
ET
T
K.
R
IG
G
S
A.
M
C C
O Y
O C
TO
B
ER
7, D .H
EN
SL
EY
FORT BUCHANAN, PUERTO RICO
U.S. ARMY RESERVE CENTER OPERATIONS BUILDING
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
K
ER D
.A
M N
B
A M
M
10/27/2023
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/202310/27/2023
10/27/2023
10/27/2023
10/27/2023
/23
VOLUME 2 OF 6
10/27/23
W
2Q R
R
_P la ns _V ol 2-
22 November 2023
W912QR24R0009
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
SHEET ID
P R
O J E
C T
N O
P
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
D R
A W
IN
G
L
IS
T
U .S
A
R M
Y R
E S
E R
V E
C E
N T
E R
O P
E R
A T
IO
N
S B
U
IL
D
IN
G
F O
R T
B U
C H
A N
A N
P
U E
R T
O R
IC
O
M B
A R
N E
T T
K R
IG
G
S
A M
C C
O Y
O C
T O
B E
R
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
E N
T U
C K
Y
G-002
D H
E N
S L E
Y
SHEET LIST
SHEET NUMBER SHEET NAME
M-713 MECHANICAL CONTROLS
ELECTRICAL
E-001 ELECTRICAL LEGEND
E-002 ELECTRICAL GENERAL NOTES & ABBREVIATIONS
EL111 PARTIAL LIGHTING PLAN
EL112 PARTIAL LIGHTING PLAN
EL113 PARTIAL LIGHTING PLAN
EL601 LIGHTING DIAGRAMS
EL701 LIGHTING SCHEDULES
EP111 PARTIAL POWER PLAN
EP112 PARTIAL POWER PLAN
EP113 PARTIAL POWER PLAN
EP130 BID OPTION 0014 - ROOF PV ARRAY PLAN
EP151 PARTIAL HVAC POWER PLAN
EP152 PARTIAL HVAC POWER PLAN
EP153 PARTIAL HVAC POWER PLAN
EP410 ENLARGED POWER PLANS
EP501 ELECTRICAL DETAILS
EP601 POWER ONE LINE DIAGRAM
EP701 PANEL SCHEDULES
EP702 PANEL SCHEDULES
EP703 PANEL SCHEDULES
EP704 PANEL SCHEDULES
EP705 PANEL SCHEDULES
EY111 PARTIAL SPECIAL SYSTEMS PLAN
EY112 PARTIAL SPECIAL SYSTEMS PLAN
EY113 PARTIAL SPECIAL SYSTEMS PLAN
EY501 SPECIAL SYSTEMS DETAILS
EG130 LIGHTNING PROTECTION PLAN
EG131 BID OPTION 0014 - LIGHTNING PROTECTION PLAN
EG501 LIGHTNING PROTECTION DETAILS
EG502 GROUNDING DETAILS
EG601 GROUNDING ONE LINE DIAGRAM
TELECOMMUNICATIONS
T-001 COMMUNICATIONS LEGENDS
T-002 COMMUNICATIONS GENERAL NOTES & ABBREVIATIONS
T-111 PARTIAL COMMUNICATIONS PLAN
T-112 PARTIAL COMMUNICATIONS PLAN
T-113 PARTIAL COMMUNICATIONS PLAN
T-410 ENLARGED COMMUNICATIONS PLANS
T-501 COMMUNICATIONS DETAILS
T-502 COMMUNICATIONS DETAILS
T-601 COMMUNICATION DIAGRAMS
T-602 COMMUNICATION ROOM 147 ELEVATION DIAGRAM
T-603 COMMUNICATION ROOM 126 ELEVATION DIAGRAM
SHEET LIST
SHEET NUMBER SHEET NAME
INTERIORS
I-001 FF&E LEGEND
I-110 COMPOSITE FURNITURE PLAN
I-111 PARTIAL FURNITURE PLAN
I-112 PARTIAL FURNITURE PLAN
I-113 PARTIAL FURNITURE PLAN
LIFE SAFETY
LS001 ABBREVIATIONS, LEGEND AND GENERAL NOTES
LS100 CODE COMPLIANCE SITE PLAN
LS110 LEVEL 1 LIFE SAFETY PLAN - COMPOSITE
FIRE PROTECTION
FP001 ABBREVIATIONS, LEGEND AND GENERAL NOTES
FP110 LEVEL 1 FIRE PROTECTION PLAN - COMPOSITE
FP501 FIRE PROTECTION DETAILS
FP502 FIRE PROTECTION DETAILS
FIRE ALARM
FA001 ABBREVIATIONS, LEGEND AND GENERAL NOTES
FA110 LEVEL 1 FIRE ALARM PLAN - COMPOSITE
FA501 FIRE ALARM DETAILS
FA502 FIRE ALARM DETAILS
PLUMBING
P-001 ABBREVIATIONS, LEGEND AND GENERAL NOTES
PP101 PARTIAL UNDERGROUND PLAN
PP102 PARTIAL UNDERGROUND PLAN
PP111 PARTIAL SANITARY PLAN
PP112 PARTIAL SANITARY PLAN
PP113 PARTIAL WATER PLAN
PP114 PARTIAL WATER PLAN
PP115 PARTIAL WATER PLAN
P-401 ENLARGED PLANS
P-402 ENLARGED PLANS
P-403 ENLARGED PLANS
P-404 ENLARGED PLANS
P-405 ENLARGED PLANS
P-406 ENLARGED PLANS
P-501 DETAILS
P-502 DETAILS
P-503 DETAILS
P-504 DETAILS
P-601 SCHEDULES
P-900 RISER DIAGRAMS
P-901 RISER DIAGRAMS
P-902 RISER DIAGRAMS
P-910 RISER DIAGRAMS
P-911 RISER DIAGRAMS
P-912 RISER DIAGRAMS
MECHANICAL
M-001 ABBREVIATIONS, LEGEND AND GENERAL NOTES
MH111 PARTIAL FLOOR PLAN - HVAC
MH112 PARTIAL FLOOR PLAN - HVAC
MH113 PARTIAL FLOOR PLAN - HVAC
MP111 PARTIAL FLOOR PLAN - PIPING
MP112 PARTIAL FLOOR PLAN - PIPING
MP113 PARTIAL FLOOR PLAN - PIPING
M-301 SECTIONS
M-411 ENLARGED PLAN - HVAC
M-412 ENLARGED PLAN - PIPING
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-503 MECHANICAL DETAILS
M-504 MECHANICAL DETAILS
M-505 MECHANICAL DETAILS
M-506 MECHANICAL DETAILS
M-507 MECHANICAL DETAILS
M-550 AIR RISER DIAGRAM
M-551 AIR RISER DIAGRAM
M-552 AIR RISER DIAGRAM
M-553 CHILLED WATER PIPING DIAGRAM
M-601 MECHANICAL SCHEDULES
M-602 MECHANICAL SCHEDULES
M-603 MECHANICAL SCHEDULES
M-701 MECHANICAL CONTROLS
M-702 MECHANICAL CONTROLS
M-703 MECHANICAL CONTROLS
M-704 MECHANICAL CONTROLS
M-705 MECHANICAL CONTROLS
M-706 MECHANICAL CONTROLS
M-707 MECHANICAL CONTROLS
M-708 MECHANICAL CONTROLS
M-709 MECHANICAL CONTROLS
M-710 MECHANICAL CONTROLS
M-711 MECHANICAL CONTROLS
M-712 MECHANICAL CONTROLS
SHEET LIST
SHEET NUMBER SHEET NAME
S-362 FRAMING SECTIONS
S-363 FRAMING SECTIONS
S-364 FRAMING SECTIONS
S-365 FRAMING SECTIONS
S-366 BID OPTION - SOLAR PANEL SUPPORT FRAMING SECTIONS
S-401 ENLARGED RAMP FOUNDATION/SLAB PLAN
S-402 RAMP SECTIONS
S-411 ENLARGED VAULT ROOF SLAB FRAMING PLAN
S-412 VAULT SECTIONS AND DETAILS
S-413 VAULT SECTIONS
S-501 TYPICAL FOUNDATION DETAILS
S-502 TYPICAL FOUNDATION DETAILS
S-503 PRECAST WALL PANEL DETAILS
S-511 TYPICAL FRAMING DETAILS
S-601 SCHEDULES
S-602 SPECIAL JOIST LOADING DIAGRAM
ARCHITECTURE
A-001 SYMBOL LEGEND
A-110 COMPOSITE FLOOR PLAN
A-111D PARTIAL DIMENSION PLAN
A-111N PARTIAL NOTE PLAN
A-112D PARTIAL DIMENSION PLAN
A-112N PARTIAL NOTE PLAN
A-113D PARTIAL DIMENSION PLAN
A-113N PARTIAL NOTE PLAN
A-130 COMPOSITE ROOF PLAN
A-140 COMPOSITE REFLECTED CEILING PLAN
A-141 PARTIAL REFLECTED CEILING PLAN
A-142 PARTIAL REFLECTED CEILING PLAN
A-143 PARTIAL REFLECTED CEILING PLAN
A-160 COMPOSITE PRECAST PANEL FLOOR PLAN
A-161 PRECAST PANEL ELEVATIONS
A-162 PRECAST PANEL DETAILS
A-181 PARTIAL SIGNAGE PLAN
A-182 PARTIAL SIGNAGE PLAN
A-183 PARTIAL SIGNAGE PLAN
A-200 COMPOSITE BUILDING ELEVATIONS
A-201 ENLARGED BUILDING ELEVATIONS
A-202 ENLARGED BUILDING ELEVATIONS
A-203 ENLARGED BUILDING ELEVATIONS
A-204 ENLARGED BUILDING ELEVATIONS
A-301 BUILDING SECTIONS
A-310 WALL SECTIONS
A-311 WALL SECTIONS
A-400 ENLARGED RESTROOM PLAN
A-401 RESTROOM DETAILS
A-402 TYPICAL RESTROOM MOUNTING HEIGHTS
A-410 RESTROOM ELEVATIONS
A-450 RAILING DETAILS
A-461 PARTIAL FINISH PLAN
A-462 PARTIAL FINISH PLAN
A-463 PARTIAL FINISH PLAN
A-500 DOOR AND FRAME TYPES AND ABA MANEUVERING
CLEARANCES
A-501 DOOR DETAILS
A-502 DOOR DETAILS
A-510 WINDOW TYPES & DETAILS
A-530 LOUVER TYPES AND DETAILS
A-540 WALL TYPES
A-541 WALL DETAILS
A-542 WALL DETAILS
A-550 COLUMN DETAILS
A-551 COLUMN DETAILS
A-560 CEILING DETAILS
A-570 ROOF DETAILS
A-571 ROOF DETAILS
A-580 MISCELLANEOUS DETAILS
A-600 DOOR SCHEDULE
A-610 FINISH SCHEDULE AND EXTERIOR FINISH KEY
A-611 FINISH KEYS & NOTES
A-620 SIGNAGE SCHEDULE
A-621 SIGNAGE DETAILS
A-700 ENLARGED VAULT DIMENSION PLAN
A-701 ENLARGED VAULT NOTED PLAN
A-710 ENLARGED CAGE PLANS
A-711 CAGE ELEVATIONS
A-712 CAGE SECTIONS AND DETAILS
A-713 CAGE DETAILS
A-800 ENLARGED KITCHEN PLAN
A-801 KITCHEN SCHEDULE
A-900 AIR BARRIER FLOOR PLAN
A-901 AIR BARRIER WALL SECTION
SHEET LIST
SHEET NUMBER SHEET NAME
GENERAL
G-001 COVER SHEET
G-002 DRAWING LIST
G-201 LOCATION AND VICINITY MAP
G-202 PROJECT AERIAL
CIVIL
V-101 OVERALL SITE SURVEY
V-111 SITE SURVEY
V-112 SITE SURVEY
B-101 OVERALL BORING PLAN
B-111 BORING PLAN
B-112 BORING PLAN
B-201 BORING LOGS
B-202 BORING LOGS
C-001 CIVIL LEGEND AND ABBREVATIONS
C-002 CIVIL GENERAL NOTES
CD101 OVERALL DEMOLITION PLAN
CD111 DEMOLITION PLAN
CD112 DEMOLITION PLAN
CG101 OVERALL GRADING AND DRAINAGE PLAN
CG111 GRADING AND DRAINAGE PLAN
CG112 GRADING AND DRAINAGE PLAN
CG201 STORM SEWER PROFILES & SCHEDULE
CG501 DRAINAGE DETAILS
CG502 DRAINAGE DETAILS
CG503 DRAINAGE DETAILS
CG701 OVERALL SEDIMENT AND EROSION CONTROL PLAN
CG711 SEDIMENT AND EROSION CONTROL PLAN
CG712 SEDIMENT AND EROSION CONTROL PLAN
CG801 SEDIMENT AND EROSION CONTROL NOTES
CG802 SEDIMENT AND EROSION CONTROL DETAILS
CG803 SEDIMENT AND EROSION CONTROL DETAILS
CG804 SEDIMENT AND EROSION CONTROL DETAILS
CG805 SEDIMENT AND EROSION CONTROL DETAILS
CG806 SEDIMENT AND EROSION CONTROL DETAILS
CS101 OVERALL SITE LAYOUT
CS111 SITE LAYOUT
CS112 SITE LAYOUT
CS401 JOINT LAYOUT PLAN
CS501 PAVEMENT DETAILS
CS502 PAVEMENT DETAILS
CS503 DESIGNATED SMOKING AREA SIGNAGE
CU101 OVERALL UTILITY PLAN
CU111 UTILITY PLAN
CU112 UTILITY PLAN
CU201 SANITARY SEWER PROFILES & SCHEDULE
CU501 SANITARY SEWER DETAILS
CU502 SANITARY SEWER DETAILS
CU511 WATER DETAILS
CU512 WATER DETAILS
LP101 OVERALL LANDSCAPE PLAN
LP111 LANDSCAPE PLAN
LP112 LANDSCAPE PLAN
ELECTRICAL
ES100 EXISTING ELECTRICAL SITE PLAN
ES101 ELECTRICAL SITE PLAN
ES501 SITE ELECTRICAL DETAILS
ES502 BID OPTION - SITE ELECTRICAL DETAILS
ES503 SITE ELECTRICAL DETAILS
TELECOMMUNICATIONS
TS101 COMMUNICATION SITE PLAN
STRUCTURAL
S-001 GENERAL STRUCTURAL NOTES AND DESIGN CRITERIA
S-002 GENERAL STRUCTURAL NOTES, DESIGN CRITERIA AND
ABBREVIATIONS
S-003 COMPONENTS AND CLADDING WIND LOAD DIAGRAM
S-111 PARTIAL FOUNDATION/FLOOR SLAB PLAN
S-112 PARTIAL FOUNDATION/FLOOR SLAB PLAN
S-113 PARTIAL FOUNDATION/FLOOR SLAB PLAN
S-114 SLAB ON GRADE CONTROL JOINT PLAN
S-131 PARTIAL ROOF FRAMING PLAN
S-132 PARTIAL ROOF FRAMING PLAN
S-133 PARTIAL ROOF FRAMING PLAN
S-141 BID OPTION - SOLAR PANEL SUPPORT FRAMING PLAN
S-200 PRECAST CONCRETE WALL ELEVATIONS KEY PLAN
S-211 CONCRETE WALL ELEVATIONS
S-212 CONCRETE WALL ELEVATIONS
S-213 CONCRETE WALL ELEVATIONS
S-251 OPERABLE PARTITION SUPPORT FRAMING ELEVATION AND
SECTION
S-301 FOUNDATION SECTIONS
S-302 FOUNDATION SECTIONS
S-361 FRAMING SECTIONS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
K
ER D
.A
M N
B
A M
M
07/22/202007/27/202011/6/202012-4-202005/04/202107/22/202108/25/202102/14/202202/15/202207/13/202207/21/202205/24/202310/27/2023
W
2Q R
R
_P la ns _V ol 2-
A M
D J R W
BT
M
10/27/2023
W
2Q R
R
_P la ns _V ol 2-
D J R W
BT
M
10/27/2023
W
2Q R
R
_P la ns _V ol 2-
D J R W
BT
M
10/27/2023
W
2Q R
R
_P la ns _V ol 2-
D J R W
BT
M
10/27/2023
W
2Q R
R
_P la ns _V ol 2-
D J R W
BT
M
10/27/2023
W
2Q R
R
_P la ns _V ol 2-
10/27/2023
10/27/2023
A M
D J R W
BT
M
W
2Q R
R
_P la ns _V ol 2-
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
AN
D D
ES
IG
N C
R
IT
ER
IA
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
C . G
IB
B
S
B.
R
EN
N
ER
D . D
IC
KE
Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
S-001
D . H
EN
SL
EY
I. GENERAL
A. THESE GENERAL NOTES PRESENT AND/OR SUMMARIZE KEY PROJECT
INFORMATION FOR THE READER'S CONVENIENCE. SEE ALSO INDIVIDUAL
PLAN NOTES AND PROJECT SPECIFICATIONS FOR FURTHER DETAILS AND
REQUIREMENTS.
B. ALL REFERENCES TO REFERENCE STANDARDS HEREIN ARE TO MOST
RECENT ISSUE IN EFFECT AS OF THE DATE OF THESE DOCUMENTS,
UNLESS NOTED OTHERWISE IN PROJECT SPECIFICATIONS OR ON THE
PLANS.
C. ELEVATIONS. ALL ELEVATIONS ARE REFERENCED TO FINISHED FLOOR EL.
100'-0". ALL ELEVATIONS SHOWN ON PLANS ARE REFERENCED TO THE
SITE ELEVATION DATUM SHOWN ON FOUNDATION PLANS UNLESS NOTED
OTHERWISE.
D. SUBMIT SHOP DRAWINGS, PROJECT DATA AND SAMPLES AS SPECIFIED IN
PROJECT SPECIFICATIONS SECTION 01 33 00.
1. IDENTIFY PROMINENTLY ON DRAWINGS EACH AND ALL RESUBMITTALS
BY NUMBER.
2. IDENTIFY ANY CHANGES WHICH HAVE BEEN MADE OTHER THAN THOSE
REQUESTED BY THE CONTRACTING OFFICER.
3. SUBMITTALS FAILING TO CONFORM TO THE ABOVE WILL BE RETURNED
FOR RESUBMITTAL.
E. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE BEGINNING WORK
OR FABRICATION AND THE CONTRACTING OFFICER SHALL BE NOTIFIED
IMMEDIATELY ON ANY DISCREPENCIES.
F. CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE SHORING AND
BRACING TO PROTECT UNFINISHED NEW CONSTRUCTION.
II. DESIGN CRITERIA
A. BUILDING CODES
2018 INTERNATIONAL BUILDING CODE.
ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES.
UFC 4-010-01, DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 12 DEC 2018 INHABITED OCCUPANCY, LOCATED WITHIN AN INSTALLATION
PERIMETER.
B. SUPERIMPOSED DESIGN LOADS
1. DEAD LOADS
ROOF DEAD LOAD (INCLUDING JOISTS) - 27 psf MIN. ROOF DEAD LOAD - 13 psf
2. LIVE LOADS
VAULT ROOF - 20 psf MECHANICAL/ELECTRICAL ROOMS - 125 psf ROOF LIVE LOAD - 20 psf
3. SNOW: GROUND SNOW LOAD = 0 psf
4. WIND:
A. BASIC WIND SPEED: 158 MPH (ULTIMATE)
B. ALLOWABLE STRESS DESIGN WIND SPEED: 122 MPH (NOMINAL)
C. RISK CATEGORY II
D. EXPOSURE CATEGORY - C
E. INTERNAL PRESSURE COEF., GCpi = +/-0.18
5. SEISMIC
A. RISK CATEGORY II, IMPORTANCE FACTOR =1.0
B. MAPPED SPECTRAL RESPONSE ACCELERATIONS
SS = 0.98g S1 = 0.39g
C. SITE CLASSIFICATION - D
D. DESIGN SPECTRAL RESPONSE ACCELERATIONS
SDS = 0.73g SD1 = 0.49g
E. SEISMIC DESIGN CATEGORY - D
F. RESPONSE MODIFICATION FACTOR, R, AND SEISMIC RESPONSE
COEFF, CS: LOAD BEARING INTERMEDIATE REINFORCED PRECAST
CONCRETE SHEAR WALLS, R = 4.0, CS = 0.183
G. DESIGN SEISMIC BASE SHEAR = 771 kips
H. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE
6. RAINFALL INTENSITY FOR 15-MIN DURATION OVER 100 YEAR RETURN:
5.33 IN/HR
7. FUTURE EXPANSION: NO PROVISION FOR FUTURE EXPANSION HAS
BEEN MADE THAT WILL IMPACT DESIGN PROVISIONS OF STRUCTURES
AND FOUNDATIONS UNDER THIS CONTRACT.
C. FOUNDATIONS
1. ALLOWABLE BEARING PRESSURE
SPREAD AND WALL FOOTINGS - 2,500 psf
2. FOUNDATIONS HAVE BEEN DESIGNED BASED ON THE
RECOMMENDATIONS OF THE SUBSURFACE EXPLORATION
AND GEOTECHNICAL REPORT PREPARED BY JACA & SIERRA
DATED APRIL 2, 2019. REPORT IS ATTACHED TO THE SPECIFICATIONS
FOR THE CONTRACTOR'S CONVENIENCE AND IS NOT A WARRANTY
OF EXISTING CONDITIONS. THE DOCUMENT AND ITS ATTACHMENTS
ARE NOT PART OF THE CONTRACT DOCUMENTS.
III. TESTING AND INSPECTION
A. FOUNDATIONS AND EARTHWORK. GEOTECHNICAL ENGINEER/TESTING
LABORATORY SHALL BE ENGAGED FOR QUALITY CONTROL AND VERIFICATION.
SEE SPECS. ALL OPEN FOUNDATION EXCAVATIONS SHALL BE INSPECTED
AND APPROVED BY A LICENSED GEOTECHNICAL ENGINEER PRIOR TO
CONCRETE PLACEMENT.
B. MATERIALS AND PROCEDURES. TESTING LABORATORY TO BE ENGAGED
FOR MATERIAL TESTING. SEE SPECS.
C. SPECIAL INSPECTOR. A SPECIAL INSPECTOR SHALL BE ENGAGED BY THE
CONTRACTOR TO INSPECT ELEMENTS AS REQUIRED. SEE SPEC 01 45 35.
IV. EARTHWORK
A. SITE PREPARATION
1. REFER TO CIVIL DRAWINGS AND SPECIFICATIONS FOR OVER-EXCAVATION
AND BACKFILL REQUIREMENTS.
2. FOUNDATION EXCAVATIONS, REFER TO SPECIFICATIONS.
3. DRAINAGE AND DEWATERING: ALL EXCAVATIONS SHALL BE
PERFORMED SO THAT THE SITE AND THE AREA IMMEDIATELY SURROUNDING
THE SITE WHICH AFFECTS CONSTRUCTION OPERATIONS WILL BE
CONTINUALLY AND EFFECTIVELY DRAINED. THE CONTRACTOR SHALL
PROVIDE DRAINAGE AND DEWATERING AS REQUIRED TO ENSURE THAT ALL
FOOTING EXCAVATIONS ARE ACCOMPLISHED WITH THE SUBGRADE SOILS
REMAINING DRY AND FIRM UNTIL AFTER FOOTINGS ARE PLACED AND
BACKFILLED. REMOVAL OF SURFACE WATER, GROUNDWATER, AND ANY
PERCHED WATER CONDITIONS WHICH MIGHT BE ENCOUNTERED DURING
EXCAVATIONS, SHALL BE ACCOMPLISHED BY APPROVED MEANS. REFER TO
SPECIFICATION SECTION 31 00 00.00 06 EARTHWORK FOR EXCAVATION
REQUIREMENTS.
B. STRUCTURAL FILLS. FILL MATERIAL COMPACTED IN 8" LIFTS
FOR HEAVY EQUIPMENT COMPACTORS, 4" LIFTS FOR HAND-OPERATED
EQUIPMENT. SEE SPECIFICATIONS FOR ACCEPTABLE FILL MATERIAL.
1. TOP 12" OF SUBGRADE UNDER BUILDING FOUNDATIONS AND SLABS-
ON-GRADE: MINIMUM DENSITY 95% ASTM D1557.
2. SUBGRADE UNDER BUILDING FOUNDATIONS AND SLABS-ON-GRADE
EXCEPT TOP 12", TO 10 FEET BEYOND BUILDING AND STRUCTURE LINE:
MINIMUM DENSITY 95% ASTM D1557.
3. GRANULAR SUBBASE UNDER SLAB-ON-GRADE: VAPOR BARRIER ON
OPEN GRADED CAPILLARY WATER BARRIER.
4. EXCEPT FOR RETAINING WALLS, FOUNDATION WALLS HAVE NOT BEEN
DESIGNED TO RESTRAIN LATERAL LOADS. BACKFILLING SHALL BE
PERFORMED SUCH THAT THE ELEVATION OF BACKFILL ON BOTH SIDES OF
THE FOUNDATION WALL IS ESSENTIALLY EQUAL (NOT TO EXCEED 2 FT)
TO AVOID UNBALANCED LOADS.
V. CAST-IN-PLACE REINFORCED CONCRETE
A. DESIGN CODE. ACI 318-14 - STRENGTH DESIGN. REFERENCE STANDARD:
ACI 301. CONTRACTOR TO MAINTAIN COPY AT JOB SITE.
B. MIX DESIGN SHALL BE DOCUMENTED IN ACCORDANCE WITH SECTION
03 30 00.00 10 OF THE PROJECT SPECS AND ACI 301, CHAPTER 3
"PROPORTIONING". MIX DESIGNS WHICH ARE SUBMITTED WITHOUT THE
REQUIRED DOCUMENTATION WILL BE REJECTED. FIELD SLUMPS
RECORDED AT JOB SITE SHALL NOT EXCEED THE SLUMP ESTABLISHED
FOR THE MIX DESIGN.
C. CONCRETE. REFER TO SPECS.
1. ALL CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 4000 psi
AT 28 DAYS.
D. FORMWORK
1. SEE SPECS.
2. KEYS INDICATED ARE TO BE 2" x 4" NOMINAL CONTINUOUS, UNO.
3. RUSTICATION STRIPS, CHAMFERS, DRIPS, MISC. EMBEDS, ETC. SEE
PLANS AND/OR ARCHITECTURAL DRAWINGS.
4. OPENINGS FOR MEP TRADES. ALL HOLES FOR OTHER TRADES WHICH
MUST BE CUT OR FORMED AND WHICH ARE NOT SHOWN ON THE
STRUCTURAL DESIGN(S) DRAWINGS SHALL BE SUBMITTED TO THE
CONTRACTING OFFICER FOR REVIEW AND APPROVAL.
5. CONTROL JOINTS IN CONCRETE WALLS SHALL BE SPACED AT 30'-0" OC
MAX. CONTROL JOINTS SHOWN ON THE DRAWINGS ARE POSSIBLE
LOCATIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR CONSTRUCTION
JOINTS IN THE WALLS. ANY CONTROL JOINT LOCATIONS SHOWN ON THE
DRAWINGS CAN BE USED FOR VERTICAL CONSTRUCTION JOINT LOCATIONS.
E. REINFORCEMENT
1. REINFORCING BARS. DEFORMED, GRADE 60, ASTM A615.
ASTM A706 WHERE SPECIFIED AND FOR WELDING APPLICATIONS.
A. FABRICATION: ACI SP-66 (2004) "ACI DETAILING MANUAL"
2. WELDED SMOOTH WIRE FABRIC - ASTM A1064. FLAT SHEETS.
3. WELDING - ACI 301, SECTION 3.2.2.2.
4. CORNER BARS. PROVIDE CORNER BARS SAME SIZE AND SPACING AS
HORIZONTAL REINFORCEMENT AT INTERSECTIONS OF ALL WALLS AND
WALL FOUNDATIONS.
5. SPLICES. CONTINUOUS REINF. BARS INCLUDING CORNER BARS SHALL
BE LAPPED THE LENGTH SHOWN IN THE DEVELOPMENT / LAP SPLICE
TABLE SHOWN ON THE DESIGN DRAWINGS.
6. MINIMUM COVER FOR PROTECTION TYPICAL, U.N.O.
A. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH - 3"
B. FORMED SURFACE EXPOSED TO EARTH OR WEATHER
#6 THROUGH #18 BARS - 2"
#5 AND SMALLER - 1 1/2"
C. STRUCTURAL SLABS AND WALLS NOT EXPOSED TO WEATHER OR IN
CONTACT WITH GROUND - 3/4"
D. BEAMS, COLUMNS, PEDESTALS, AND TENSION TIES: PRIMARY
REINFORCEMENT, TIES, STIRRUPS, AND SPIRALS NOT EXPOSED
TO WEATHER OR IN CONTACT WITH GROUND - 1 1/2"
7. HOOKS INDICATED ARE ACI/CRSI STANDARD 90 DEG. OR 180 DEG.
HOOKS. BAR LENGTHS SHOWN ARE OUT-TO-OUT AND DO NOT INCLUDE
HOOK LENGTH
F. SLAB & WALL OPENINGS. COORDINATE WITH MECHANICAL, PLUMBING AND
ELECTRICAL TRADES. FIELD REQUIREMENTS NOT SHOWN ON STRUCTURAL
PLANS MUST BE APPROVED BY THE CONTRACTING OFFICER. ANY
STRENGTHENING OR ADDITIONAL REINFORCEMENT REQUIRED SHALL
BE FURNISHED BY THE CONTRACTOR WITHOUT ADDITIONAL COST TO
THE GOVERNMENT. PLUMBING SLOTS ARE TO BE FILLED WITH CONCRETE
TO SAME THICKNESS AS SLAB OR WALL AFTER PIPING HAS BEEN INSTALLED.
SEE TYPICAL SLAB PENETRATION DETAILS FOR REQUIREMENTS.
G. EMBEDDED PIPES OR CONDUIT. MAXIMUM DIAMETER - 1/3 x SLAB OR
WALL THICKNESS, SPACED MINIMUM OF 3 DIAMETERS ON CENTER.
H. GROUT. HIGH STRENGTH, NON-SHRINK STRUCTURAL GROUT. SEE SPECS.
I. CONCRETE FINISHES. SEE SPECS.
1. FORMED SURFACES:
A. PAINTED OR EXPOSED TO VIEW: RUBBED, U.N.O. ON PLANS
B. COVERED OR AS NOTED ON PLANS: AS-CAST
2. FLATWORK SURFACES:
A. EXPOSED TO VIEW: TROWELED WITH SURFACE TREATMENT
B. TILED OR CARPETED: TROWELED
C. STAIRS OR RAMPS: BROOMED
D. SIDEWALKS, DRIVEWAYS: BROOMED OR BELTED
J. CURING AND PROTECTION. SEE SPECS.
K. SLABS ON GRADE
1. STRIP CAST WITH CONTROL/CONSTRUCTION JOINTS TO ALIGN WITH
COLUMN CENTERLINES. CONTROL JOINTS SHALL BE PLACED AS
SHOWN ON PLANS.
2. SEE CONTROL JOINT AND CONSTRUCTION JOINT DETAILS. CONTROL
JOINT MAXIMUM SPACING IS 18'-0".
VI. STRUCTURAL STEEL
A. DESIGN, FABRICATION, AND ERECTION. AISC 360-16. SPECIFICATION FOR
STRUCTURAL STEEL BUILDINGS.
B. DESIGN METHOD: LOAD AND RESISTANCE FACTOR DESIGN (LRFD)
C. GRADE STEEL. WIDE FLANGE SHAPES - ASTM A992 (GRADE 50)
CHANNELS, ANGLES, AND MISC. SHAPES - ASTM A36
TUBE (HSS) SHAPES - ASTM A500, GRADE C (46 KSI MIN. YIELD STRENGTH
FOR ROUND SHAPES, 50 KSI MIN. YIELD STRENGTH FOR RECTANGULAR SHAPES).
D. CONNECTIONS. AISC MANUAL STANDARD CONNECTIONS UNLESS NOTED.
1. HIGH-STRENGTH BOLTS: ASTM F3125 GRADE A325 BEARING TYPE INSTALLED
IN CONFORMANCE WITH "SPECIFICATIONS FOR STRUCTURAL JOINTS
USING HIGH STRENGTH BOLTS", RESEARCH COUNCIL ON STRUCTURAL
CONNECTIONS. U.N.O., STANDARD AISC "USUAL GAGE" DIMENSIONS
SHALL BE USED FOR LOCATING HOLES FOR BOLTS, EXPANSION
ANCHORS, ETC. IN ALL ANGLES, BEAM FLANGES, ETC.
2. WELDS: AWS D1.1/D1.8, SERIES E70XX. ALL WELDS SHALL BE SUBJECT TO
INSPECTION AND NONDESTRUCTIVE EXAMINATION AS REQUIRED IN
SPECIFICATIONS. WHERE WELD SIZE IS NOT INDICATED ON THE
DRAWINGS, USE MINIMUM SIZE FOR PREQUALIFIED JOINTS PER
AWS D1.1/D1.8.
3. ANCHOR RODS: ANCHOR RODS SHALL CONFORM TO ASTM F1554,
GRADE 36.
4. SIMPLE SHEAR CONNECTIONS: STEEL FABRICATOR SHALL DESIGN
CONNECTIONS FOR THE REACTIONS SHOWN ON THE DRAWINGS.
WHERE REACTIONS ARE NOT SHOWN, DESIGN NON-COMPOSITE
BEAM CONNECTIONS FOR 50% OF THE FULL CAPACITY
OF THE BEAM.
E. TOLERANCES. AISC CODE OF STANDARD PRACTICE 2016, SECTION 6.4,
7.12, AND 7.13.
F. ROOF OPENINGS. VERIFY SIZE AND LOCATION OF REQUIRED
OPENINGS WITH MECHANICAL, PLUMBING, OR OTHER TRADES AS
NECESSARY TO ASSURE CORRECT FRAMING AND SUBMIT ON SHOP
DRAWINGS. PROVIDE SUB-SUPPORT AS REQUIRED FOR DECK CLOSURES
TYPICAL, INCLUDING AT COLUMNS. COORDINATE WITH DECK SUPPLIER.
G. SHOP DRAWINGS. SUBMIT ERECTION AND FABRICATION SHOP DRAWINGS,
STAMPED AND SEALED BY A REGISTERED ENGINEER. SEE SPECS.
VII. METAL ROOF DECK
A. DESIGN, FABRICATION, & ERECTION. STEEL DECK INSTITUTE (SDI)
DESIGN MANUAL. CONFORM TO RECOMMENDATIONS FOR STEEL
DECK DIAPHRAGM, DDM03.
B. MATERIAL. ASTM A653 TYPE SS (40 ksi MIN. YIELD STRENGTH)
C. METAL ROOF DECK, 1 1/2" DEEP, 0.0358" THICK (20 GAUGE) WIDE
RIB WITH THE FOLLOWING MINIMUM SECTION PROPERTIES:
Ix = 0.201 in4/ft; S(+) = 0.234 in3/ft; S(-) = 0.247 in3/ft
D. INSTALLATION. WHERE POSSIBLE, EXTEND OVER 3 OR MORE
SUPPORTS. DECK ATTACHMENTS SHALL BE IN ACCORDANCE WITH
SDI SPECS AND SHALL BE ADEQUATELY SHOWN ON DECK SHOP
DRAWINGS FOR FIELD INSTALLATION. ANCHOR TO RESIST THE NET
UPLIFT PRESSURE AS SHOWN ON THE PLANS.
E. DECK ATTACHMENT SHALL BE WITH 1/2" PUDDLE WELDS ON 36/7
PATTERN WITH #10 TEK SCREW SIDELAP FASTENERS AT 12" OC MAX.
MECHANICAL FASTENERS MAY BE USED ON A PATTERN PRODUCING
STRENGTH AND STIFFNESS AT LEAST EQUAL TO THE WELDED
ATTACHMENT. WELDED SIDELAPS NOT PERMITTED.
F. ACCESSORIES. RIDGE AND VALLEY PLATES AND CANT STRIPS
ATTACHED DIRECTLY TO STEEL DECK INCLUDED. GAGE TO MATCH
ROOF DECK.
G. FINISH. G90 GALVANIZED
H. SHOP DRAWINGS. SUBMIT SHOP DRAWINGS.
GENERAL STRUCTURAL NOTES
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
BK
R
D D
10/27/2023
W
2Q R
R
_P la ns _V ol 2-
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S, D
ES
IG
N C
R
IT
ER
IA
A N
D A
BB
R
E
VI
AT
IO
N S
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
C . G
IB
B
S
B.
R
EN
N
ER
D . D
IC
KE
Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
S-002
D . H
EN
SL
EY
VII. ADHESIVE AND EXPANSION ANCHORS
A. ADHESIVE ANCHORS SHALL CONSIST OF AN EQUAL TWO-COMPONENT
STRUCTURAL GRADE EPOXY INJECTION MATERIAL CONFORMING TO
ASTM C881. ROD MATERIAL SHALL MEET MIN. MATERIAL
SPECIFICATIONS OF ASTM A193, GRADE B7 OR APPROVED EQUAL.
B. REINFORCING BAR ANCHORS SHALL BE DEFORMED, GRADE 60,
ASTM A615.
C. CHEMICAL ANCHORS SHALL MEET THE MINIMUM MATERIAL
SPECIFICATIONS OF ASTM A193, GRADE B7 OR APPROVED EQUAL.
EXPANSION ANCHORS SHALL BE GALVANIZED, CARBON STEEL.
D. ANCHORAGE SYSTEMS SHALL BE APPROVED BY THE CONTRACTING
OFFICER. PRIOR TO USE.
E. INSTALLATION SHALL BE IN CONFORMANCE WITH MANUFACTURER'S
PRINTED LITERATURE AND SHALL INCLUDE THE BRUSHING AND
CLEANING OF DRILLED HOLES WITH COMPRESSED AIR. INSTALLERS
SHALL BE TRAINED BY THE MANUFACTURER'S REPRESENTATIVE.
EMBEDMENT DEPTH SHALL BE AS INDICATED ON THE STRUCTURAL
DRAWINGS.
F. CONTRACTOR SHALL TAKE PRECAUTIONS NECESSARY DURING THE
DRILLING PROCESS TO AVOID DAMAGING EXISTING REINFORCEMENT.
ABANDON HOLES THAT INTERFERE WITH REINFORCEMENT, HAVE
INCORRECT DIAMETER OR SPALLING DAMAGE, AND FILL WITH GROUT.
DRILL HOLES AS REQUIRED.
G. PROOF LOAD TESTING. PERIODICALLY PROOF LOAD 25% OF EACH TYPE AND
SIZE OF DRILLED-IN ADHESIVE ANCHOR IN ACCORDANCE WITH THE
RECOMMENDATIONS OF THE ANCHOR MANUFACTURER. PROOF LOADING
SHALL BE PERFORMED AT 50% OF THE MEAN BOND STRENGTH OR 80% OF
THE ROD YIELD STRENGTH, WHICHEVER IS LESS. IF MORE THAN 10%
OF THE TESTED ANCHORS FAIL TO ACHIEVE THE SPECIFIED LOAD WITHIN THE
LIMITS, ALL ANCHORS OF THE SAME DIAMETER AND TYPE AS THE FAILED
ANCHOR SHALL BE TESTED. DISPLACEMENT OF ANCHORS AT PROOF LOAD
SHALL NOT EXCEED D/10, WHERE D IS THE NOMINAL ANCHOR DIAMETER.
VIII. OPEN-WEB STEEL JOIST
A. DESIGN, FABRICATION, AND USE. SJI SPECS.
B. DETAILS. JOISTS TO BE WELDED OR BOLTED TO SUPPORTS. REFER
TO SECTIONS AND DETAILS FOR JOIST SEAT DEPTHS. EXTEND BOTTOM
CHORD OF JOIST TO COLUMN ON COLUMN LINES. PROVIDE VERTICAL
STABILIZER PLATE TO RECEIVE BOTTOM CHORD.
C. PAINT. PRIME AND PAINT IN ACCORDANCE WITH SPECS.
D. CONCENTRATED LOADS. ATTACH IN SUCH A MANNER OR AT SUCH A
LOCATION (I.E. PANEL POINTS) SO THAT LOCAL BENDING IS NOT
INDUCED IN THE CHORDS EXCEPT AS INDICATED. FOR ALL
CONCENTRATED LOADS NOT OCCURRING AT JOIST PANEL POINTS,
AN EXTRA WEB MEMBER MUST BE FIELD APPLIED.
E. BRIDGING AND/OR DIAGONAL BRACING TO BE COLLINEAR WHERE
EXPOSED TO VIEW. ANY BRIDGING SHOWN ON PLANS IS A MINIMUM
REQUIREMENT. ACTUAL BRIDGING REQUIREMENTS SHALL BE
DETERMINED BY THE JOIST SUPPLIER AS RECOMMENDED BY THE SJI.
F. SUBMIT SHOP DRAWINGS INCLUDING UPLIFT DESIGN CALCULATIONS.
SEE SPECS.
ABBREVIATIONSGENERAL STRUCTURAL NOTES CON'TD
IX. PRECAST CONCRETE WALL PANELS
A. DESIGN, FABRICATION, AND ERECTION. PRECAST CONCRETE INSTITUTE
(PCI) DESIGN MANUAL.
B. DESIGN FOR THE LOADS AS INDICATED ON THE DRAWINGS AND AS
REQUIRED IN THE SPECIFICATIONS.
C. ALL PRECAST CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH
OF 5000 psi AT 28 DAYS, UNO ON PLANS OR SPECIFICATIONS.
D. PRECAST MFR IS RESPONSIBLE FOR FINAL LAYOUT, DIMENSIONS
AND JOINTING OF WALL PANELS. PANEL THICKNESSES SHOWN ARE MINIMUMS.
E. PRECAST MFR IS RESPONSIBLE FOR ALL CONNECTIONS BETWEEN PANELS,
AND ANCHORAGE TO THE FOUNDATION.
F. PRECAST MFR SHALL COORDINATE WALL OPENINGS/PENETRATIONS
WITH OTHER TRADES. PROVIDE ADD'L REINFORCEMENT AS REQ'D.
G. REINFORCEMENT, DEFORMED, GRADE 60, ASTM A615. ASTM A706 FOR
WELDING APPLICATIONS.
H. MINIMUM REINFORCEMENT RATIO - 0.0018
I. SUBMIT SHOP DRAWINGS.
NOM NOMINAL
NORM WT NORMAL WEIGHT
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OSL OUTSTANDING LEG
PAF POWDER ACTUATED FASTENERS
PC PRECAST
PE PROFESSIONAL ENGINEER
PERP PERPENDICULAR
PL PLATE
PLB PLUMBING
PLYWD PLYWOOD
POJ PLANE OF JOIST
PROJ PROJECT
PVG PAVING
PVMT PAVEMENT
QTY QUANTITY
QUAL QUALITY
R RADIUS
RD ROOF DRAIN
REC RECESSED
RECT RECTANGLE
REF REFERENCE
REINF REINFORCING
REQD REQUIRED
REV REVISE, REVISION
RO ROUGH OPENING
SCHED SCHEDULE
SECT SECTION
SHT SHEET
SIM SIMILAR
SOG SLAB ON GRADE
SPEC SPECIFICATION
SQ SQUARE
STD STANDARD
STIF STIFFENER
STL STEEL
STRUC STRUCTURE(AL)
SW SHEAR WALL
SYMM SYMMETRICAL
T&B TOP AND BOTTOM
THK THICKNESS
TO TOP OF
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOSL TOP OF SLAB
TOW TOP OF WALL
TRTD TREATED
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VB VAPOR BARRIER
VERT VERTICAL
VIF VERIFY IN FIELD
W WIDTH
w/ WITH w/o WITHOUT
WCJ WALL CONTROL JOINT
WD WOOD
WL WIND LOAD
WP WORKING POINT
WT WEIGHT
WWR WELDED WIRE REINFORCEMENT
EMBED EMBEDMENT
ENG ENGINEER
EOD EDGE OF DECK
EOS EDGE OF SLAB
EPX EPOXY
EQ EQUAL
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ES EACH SIDE
EW EACH WAY
EXP EXPANSION
EXST EXISTING
EXT EXTERIOR
FD FLOOR DRAIN
FDN FOUNDATION
FF FINISH FLOOR
FIN FINISH(ED)
FLR FLOOR
FO FACE OF
FS FAR SIDE
FTG FOOTING
GA GAGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GR GRADE
GR BM GRADE BEAM
HC HOLLOW CORE
HD HEADED
HK HOOK
HLDN HOLD DOWN
HORIZ HORIZONTAL
HP HIGH POINT
HS HIGH STRENGTH
HT HEIGHT
HVAC HEATING-VENTILATING-AIR CONDITIONING
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
INCL INCLUDE(ED)(ING)
INFO INFORMATION
INT INTERIOR
JST JOIST
JT JOINT
KB KNEE BRACE
KWY KEYWAY
L LENGTH
Ld DEVELOPMENT LENGTH
LL LIVE LOAD
LLBB LONG LEG BACK TO BACK
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LT WT LIGHTWEIGHT
LVL LAMINATED VENEER LUMBER
LW LONG WAY
MATL MATERIAL
MAX MAXIMUM
MBM METAL BUILDING MANUFACTURER
MCJ MASONRY CONTROL JOINT
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOV MOVABLE
MTL METAL
NA NOT APPLICABLE
NF NEAR FACE
NIC NOT IN CONTRACT
NO, # NUMBER
& AND
@ AT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ACI AMERICAN CONCRETE INSTITUTE
ADDL ADDITIONAL
ADH ADHESIVE
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECT, ARCHITECTURAL
ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
B/B BACK TO BACK
BB BOND BEAM
BE BOUNDARY ELEMENT
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BLW BELOW
BM BEAM
BO BOTTOM OF
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BASE PLATE
BRDG BRIDGING
BRG BEARING
BS BOTH SIDES
BTWN BETWEEN
C/C CENTER TO CENTER
CANT CANTILEVER
CFS COLD-FORMED STEEL
CIP CAST IN PLACE
CJ CONTROL JOINT
CJP COMPLETE JOINT PENETRATION
CL CENTERLINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
COR CONTRACTING OFFICER
CTR CENTER
D DEPTH
db BAR DIAMETER
DEMO DEMOLITION
DEPR DEPRESSION
DIA, Ø DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIR DIRECTION
DL DEAD LOAD
DN DOWN
DO DITTO
DTL DETAIL
DWG DRAWING
DWL DOWEL
EA EACH
EE EACH END
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
BK
R
D D
10/27/2023
W
2Q R
R
_P la ns _V ol 2-
1'
1 2
1 2
TY
P
TY
P
TYP
13' - 5"
TYP
13' - 5"
TYP
13' - 5"
TYP
13' - 5"
TY
P
TY
P
COMPONENTS & CLADDING WIND
LOAD (psf)
23.9
POSITIVE
<10 SF 100 SF 200 SF >500 SF
ROOF
NEGATIVE
100 SF
53.9
POSITIVE
<10 SF 50 SF <10 SF 50 SF
WALLS
NEGATIVE
200 SF >500 SF200 SF >500 SF
NOTES:
1. WALL SECTION 5 EXTENDS FROM BUILDING CORNER 9'-9".
2. WIND PRESSURES SHOWN ARE AT THE ULTIMATE LEVEL.
(i.e. THE 0.6 LOAD FACTOR HAS NOT BEEN APPLIED.)
1'
<10 SF 200 SF 500 SF >1000 SF
23.9
53.9
18.9
18.9
45.9
18.9
18.9
43.5
18.9
18.9
40.4
-93.8
-53.9
-123.7
-73.2
-53.9
-97.3
-67.0
-40.8
-89.3
-58.8
-36.4
-78.8
-58.8
-28.9
-78.8
48.3 43.5 40.4 -58.3
-71.8
-52.8
-60.7
-48.0
-51.2
-44.9
-44.953.9 48.3 43.5 40.4
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
C O
M
PO
N
EN
TS
A
N D
C
LA
D D
IN
G
W
IN
D L
O
AD
D
IA
G R
AM
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
C . G
IB
B
S
B.
R
EN
N
ER
D . D
IC
KE
Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
S-003
D . H
EN
SL
EY
SCALE: NTS
COMPONENTS AND CLADDING PRESSURES
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
BK
R
D D
10/27/2023
W
2Q R
R
_P la ns _V ol 2-
6 8 9 10
E
A
B
C
M
AT
C H
LI
N
E -S
EE
S
-1
M
AT
C H
LI
N
E -S
EE
S
-1
1"
0"
6'
4" 5'
9"
3'
4"
26' - 10" 22' - 10" 26' - 4"
3' - 4" 27' - 6"
C S-301
A S-301
F4.0F4.0
F5.0 F4.0
F4.0
F5.0
F4.0
WF-2
WF-2
W F-
( 90' - 6" )
( 95' - 6" )
B S-301
TYP2
TYP 1
SOG1A
( 94' - 6" ) ( 92' - 6" )
MATCHLINE - SEE S-113
3' - 4"
A S-301
( 96' - 6" )
( 95' - 0" )
( 93' - 6" )
( 98' - 0" )
TYP5
C W
-1
W F-
CW-1
CW-2
C W
-2
3'
4"
S-401
( 98' - 0" )
( 95' - 0" )
( 96' - 6" )
( 98' - 0" )
S-251
( 92' - 2" )
( 93' - 10" )
( 98' - 0" )
( 96' - 9" )C W
-2
TYP6
( 96' - 6" )
( 98' - 0" )
TYP4
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
F O
U N
D
AT
IO
N
/F
LO
O R
S
LA
B
PL
AN
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
C . G
IB
B
S
B.
R
EN
N
ER
D . D
IC
KE
Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
S-111
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"
PARTIAL FOUNDATION/FLOOR SLAB PLAN
GENERAL SHEET NOTES
1 REFER TO S-001 AND S-002 FOR GENERAL NOTES.
2 ALL DIMENSIONS ARE TO INSIDE FACE OF PRECAST.
3 "WF-X" INDICATES REINFORCED CONCRETE WALL
FOUNDATION. SEE SHEET S-601 FOR WALL FOOTING
SCHEDULE. TOP OF FOUNDATION ELEVATION = 98'-0" UNO
AS (XX'-XX").
4 "CW-X" INDICATES REINFORCED CONCRETE WALL. SEE
SHEET S-601 FOR CONCRETE WALL SCHEDULE.
5 "FX.X" INDICATES REINFORCED CONCRETE COLUMN
FOOTING. SEE SHEET S-601 FOR COLUMN FOOTING
SCHEDULE. TOP OF FOOTING ELEVATION = 98'-0" UNO.
6 "SOGXX" INDICATES CONCRETE SLAB ON GRADE. SEE
S-601 FOR CONCRETE SLAB ON GRADE SCHEDULE. TOP
OF SLAB ELEVATION = 100'-0", UNO. SITE ELEVATION =
64.75'. REFER TO S-114 FOR SLAB ON GRADE CONTROL
JOINT PLAN.
SHEET KEYNOTES
1 STEPPED FOOTING. REFER TO TYPICAL DETAIL ON SHEET
S-501.
2 FLOOR DRAIN. REFER TO TYPICAL DETAIL ON SHEET
S-501.
3 SLAB DEPRESSION FOR EQUIPMENT TROUGH. SEE
TYPICAL SLAB DEPRESSION DETAIL ON SHEET S-501.
4 HALF GRATE FLOOR DRAIN. REFER TO PLUMBING
DRAWINGS.
5 CONC PAVING, REFER TO CIVIL.
6 BOLLARD. SEE TYPICAL DETAILS ON SHEET S-502 FOR
SIZE AND PLACEMENT OF BOLLARDS.
7 EXTERIOR EQUIPMENT PAD. REFER TO CIVIL DRAWINGS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
10/27/2023
BK
R
D D
W
2Q R
R
_P la ns _V ol 2-
1 2 3 4 5 6
A
B
C
MATCHLINE - SEE S-113
1"
0"
0"
6'
4"
12' - 2"
23' - 8" 21' - 10" 16' - 6" 17' - 6" 23' - 2" 18' - 8"
M
AT
C H
LI
N
E -S
EE
S
-1
C S-301
D
F4.0 F4.0 F4.0 F4.0 F4.0
F4.0
F4.0F4.0F4.0F4.0F4.0
F4.0 F7.0 F7.0
F4.0
F5.0 F5.0
F5.0
F5.0
3.5
E S-301
D S-301
F S-301
WF-1
W F-
W F-
W F-
WF-1
W F-
( 94' - 6" )
TYP1
WF-2
TYP2
F4.0
SOG1A
SOG2
A S-302
( 94' - 6" )
( 96' - 3" )
( 98' - 0" )
WF-4
11" 3' - 4"
19' - 1" 6' - 4" 4' - 4"
M
AT
C H
LI
N
E -S
EE
S
-1
MATCHLINE - SEE S-113
A S-301
B S-301
TYP 3
CW-2
C W
-2 C
W -1
W F-
CW-1
C W
-1
C W
-7
CW-7
C W
-7
CW-7
C W
-7
( 98' - 0" )
( 96' - 8" )
( 95' - 4" )
( 96' - 8" )( 98' - 0" )
TYP4
W F-
( 93' - 4" ) ( 92' - 2" )( 93' - 4" )
( 94' - 6" )
( 98' - 0" ) ( 96' - 6" )
( 95' - 0" ) ( 96' - 6" )
( 98' - 0" ) TYP6
6'
3/
8"
3' - 4" 3' - 6" 3' - 10"
6' - 10 5/8" 67' - 4"
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
F O
U N
D
AT
IO
N
/F
LO
O R
S
LA
B
PL
AN
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
C . G
IB
B
S
B.
R
EN
N
ER
D . D
IC
KE
Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
S-112
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"
PARTIAL FOUNDATION/FLOOR SLAB PLAN
SHEET KEYNOTES
1 STEPPED FOOTING. REFER TO TYPICAL DETAIL ON SHEET
S-501.
2 FLOOR DRAIN. REFER TO TYPICAL DETAIL ON SHEET
S-501.
3 CONC PAVING, REFER TO CIVIL.
4 EXTERIOR EQUIPMENT PAD. REFER TO CIVIL DRAWINGS.
5 STEPPED FOOTING. COORDINATE LOCATIONS WITH SITE
UTILITIES. SEE S-501 FOR STEP FOOTING DETAIL.
6 INTERIOR EQUIPMENT PAD. REFER TO TYPICAL DETAIL
ON SHEET S-501. SEE MECHANICAL DRAWINGS FOR SIZE
AND LOCATION.
GENERAL SHEET NOTES
1 REFER TO S-001 AND S-002 FOR GENERAL NOTES.
2 ALL DIMENSIONS ARE TO INSIDE FACE OF PRECAST.
3 "WF-X" INDICATES REINFORCED CONCRETE WALL
FOUNDATION. SEE SHEET S-601 FOR WALL FOOTING
SCHEDULE. TOP OF FOUNDATION ELEVATION = 98'-0" UNO
AS (XX'-XX").
4 "CW-X" INDICATES REINFORCED CONCRETE WALL. SEE
SHEET S-601 FOR CONCRETE WALL SCHEDULE.
5 "FX.X" INDICATES REINFORCED CONCRETE COLUMN
FOOTING. SEE SHEET S-601 FOR COLUMN FOOTING
SCHEDULE. TOP OF FOOTING ELEVATION = 98'-0" UNO.
6 "SOGXX" INDICATES CONCRETE SLAB ON GRADE. SEE
S-601 FOR CONCRETE SLAB ON GRADE SCHEDULE. TOP
OF SLAB ELEVATION = 100'-0", UNO. SITE ELEVATION =
64.75'. REFER TO S-114 FOR SLAB ON GRADE CONTROL
JOINT PLAN.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
10/27/2023
BK
R
D D
W
2Q R
R
_P la ns _V ol 2-
F
G
H
J
83' - 0" 3' - 4" 65' - 6" 3' - 4" 15' - 2"
MATCHLINE - SEE S-112
22' - 6" 23' - 8" 21' - 10" 34' - 0" 23' - 2" 18' - 8" 5' - 4" 21' - 2"
3'
4"
1" 3'
4"
170' - 4"
C S-301
A S-301
A S-301
B S-301
F4.0F4.0 F4.0 F4.0 F4.0
F4.0 F4.0 F4.0 F4.0 F4.0F4.0
F4.0 F4.0 F4.0 F4.0 F4.0 F4.0
F4.0F4.0F4.0F4.0F4.0F4.0
F4.0 F4.0 F4.0 F4.0 F4.0 F4.0
8'
1"
3'
7"
3'
4"
WF-1
WF-2
W F-
F4.0
SOG1A
TYP1
M
AT
C H
LI
N
E -S
EE
S
-1
MATCHLINE - SEE S-111
TYP2
E S-301
CW-7
C W
-1
C W
-1
CW-1
W
F-
TYP3
TYP4
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
F O
U N
D
AT
IO
N
/F
LO
O R
S
LA
B
PL
AN
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
C . G
IB
B
S
B.
R
EN
N
ER
D . D
IC
KE
Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
S-113
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"
PARTIAL FOUNDATION/FLOOR SLAB PLAN
GENERAL SHEET NOTES
1 REFER TO S-001 AND S-002 FOR GENERAL NOTES.
2 ALL DIMENSIONS ARE TO INSIDE FACE OF PRECAST.
3 "WF-X" INDICATES REINFORCED CONCRETE WALL
FOUNDATION. SEE SHEET S-601 FOR WALL FOOTING
SCHEDULE. TOP OF FOUNDATION ELEVATION = 98'-0" UNO
AS (XX'-XX").
4 "CW-X" INDICATES REINFORCED CONCRETE WALL. SEE
SHEET S-601 FOR CONCRETE WALL SCHEDULE.
5 "FX.X" INDICATES REINFORCED CONCRETE COLUMN
FOOTING. SEE SHEET S-601 FOR COLUMN FOOTING
SCHEDULE. TOP OF FOOTING ELEVATION = 98'-0" UNO.
6 "SOGXX" INDICATES CONCRETE SLAB ON GRADE. SEE
S-601 FOR CONCRETE SLAB ON GRADE SCHEDULE. TOP
OF SLAB ELEVATION = 100'-0", UNO. SITE ELEVATION =
64.75'. REFER TO S-114 FOR SLAB ON GRADE CONTROL
JOINT PLAN.
SHEET KEYNOTES
1 FLOOR DRAIN. REFER TO TYPICAL DETAIL ON SHEET
S-501.
2 CONC PAVING, REFER TO CIVIL.
3 BOLLARD. SEE TYPICAL DETAILS ON SHEET S-502 FOR
SIZE AND PLACEMENT OF BOLLARDS.
4 EQUIPMENT PAD. REFER TO TYPICAL DETAIL ON SHEET
S-501. SEE MECHANICAL DRAWINGS FOR SIZE AND
LOCATION.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
10/27/2023
BK
R
D D
W
2Q R
R
_P la ns _V ol 2-
1 2 3 4 5 6 8 9 10
A
B
C
F
G
H
J
D
3.5
TYP1
GRAPHIC SCALE: = 1'-0"
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
SL
AB
O N
G R
AD
E
C O
N
TR
O L
JO
IN
T
PL
AN
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
C . G
IB
B
S
B.
R
EN
N
ER
D . D
IC
KE
Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
S-114
D . H
EN
SL
EY
SCALE: 1/16" = 1'-0"
SLAB ON GRADE CONTROL JOINT PLAN
SHEET KEYNOTES
1 CONTROL JOINT. REFER TO DETAIL 3/S-501 FOR TYPICAL
CONTROL JOINT DETAILS.
GENERAL SHEET NOTES
1 REFER TO S-001 AND S-002 FOR GENERAL NOTES.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
BK
R
D D
10/27/2023
W
2Q R
R
_P la ns _V ol 2-
6 8 9 10
A
B
C
M
AT
C H
LI
N
E -S
EE
S
-1
W12X26
(POJ)
W12X26
(POJ)
W12X22
(POJ)
W12X22 W
X3
(1
3/ 4"
W
X3
(1
3"
W
X3
(1
1/ 2"
W
X4
(1
1/ 2"
W
X4
(1
3"
W
X4
(1
3/ 4"
W
X3
(1
3/ 4"
0"
1"
26' - 10" 22' - 10" 26' - 4" 27' - 6"
W12X26
(POJ)
W12X26
(POJ)
A S-361
B S-361
B S-361
'-1 " O
C
K4
S P-
4'
1"
'-1 " O
C
K3
4'
1"
'-1 1"
O C
K3
4'
'-4 " O
C
K3
4'
4"
'-4 " O
C
K3
4'
4"
'-1 1"
O C
K3
4'
'-1 " O
C
K3
4'
1"
C S-361
D S-361
MATCHLINE - SEE S-133
JST BRG EL
= 119'-0"
9'
4"
W
X4
(1
3/ 4"
B S-362
C S-362
A S-362
D S-362
3.5k
3.5k
3.5k
3.5k
3.5k
3.5k
3.9k
3.9k
3.9k
3.9k
3.9k
3.9k
3.9k
3.9k
3.9k
3.9k
3.9k
3.9k
3.3k
3.3k
3.3k
3.3k
3.3k
4'
4"
'-4 " O
C
K3
.0 k
.0 k
.3 k
.3 k
.0 k
.0 k
'-1 " O
C
K3
4'
1"
5'
6"
'-1 1"
O C
K4
S P-
4'
4'
-1 0"
O C
K4
4'
'-0 " O
C
K4
4'
0"
JST GRIDER BRG EL = 121' - 7" JST GRIDER BRG EL = 120' - 7 1/2"
G
N
5.
0K
(1
3"
4'
'-1 1"
O C
K3
24K4 SP-1
24K4
24K4
G
N
5.
0K
(1
1/ 2"
3.5k
93' - 2"
2.3k
JST BRG EL
= 122'-10 3/4"
A S-365
A S-363
12K1
C S-362
SLOPE
DN
W14X226"
0" (111'-0")
(POJ)
TYP 1
INDICATES SPAN DIRECTION OF 1 1/2" METAL ROOF DECK.
SEE GENERAL NOTES FOR ATTACHMENT REQUIREMENTS.
LEGEND
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
R O
O F
FR
AM
IN
G
P
LA
N
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
C . G
IB
B
S
B.
R
EN
N
ER
D . D
IC
KE
Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
S-131
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"
PARTIAL ROOF FRAMING PLAN
GENERAL SHEET NOTES
1 REFER TO S-001 AND S-002 FOR GENERAL NOTES.
2 TOP OF STEEL ELEVATION IS REFERENCED FROM
FINISHED FLOOR ELEVATION 100'-0".
3 ALL DIMENSIONS ARE TO INSIDE FACE OF PRECAST.
4 REACTIONS SHOWN ARE FACTORED VERTICAL GRAVITY
LOADS. THESE REACTIONS DO NOT INCLUDE EFFECTS
FROM WIND.
SHEET KEYNOTES
1 KNEE BRACE BETWEEN JOIST BOTTOM CHORD AND BEAM
BOTTOM FLANGE. SEE TYPICAL JOIST KNEE BRACE
DETAIL ON S-511.
2 CONDENSATION HOOD. REFER TO MECH FOR
INFORMATION. WEIGHT = 150 LB.
3 EXHAUST HOOD. REFER TO MECH FOR INFORMATION.
WEIGHT = 1000 LB.
4 STRUT CHANNEL FOR OPERABLE PARTITION SUPPORT.
REFER TO SPECIAL JOIST LOADING DIAGRAM ON SHEET
S-602.
5 CANOPY, REFER TO ARCH DWGS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
10/27/2023
BK
R
D D
W
2Q R
R
_P la ns _V ol 2-
A
B
C
1"
0"
0"
23' - 8" 21' - 10" 34' - 0" 23' - 2" 18' - 8"
W
X4
(1
9"
W
X4
(1
8"
W
X6
(1
1"
W
X6
(1
1/ 4"
W
X6
(1
4"
W12X16
(POJ)
W12X22
(POJ)
W14X30
(POJ)
W12X22
(POJ)
W14X30
(POJ)
W12X22
(POJ)
W12X16
(POJ)
W12X22
(POJ)
W14X30
(POJ)
W12X16
(POJ)
W12X22
(POJ)
W
X4
(1
4"
W
X4
(1
1/ 4"
W
X4
(1
1"
W
X4
(1
8"
W
X4
(1
9"
W
X4
(1
9"
W
X4
(1
8"
W
X7
(1
1"
W
X7
(1
1/ 4"
W
X7
(1
4"
W
X4
(1
4"
W
X4
(1
1/ 4"
W
X4
(1
1"
W
X3
(1
8"
W
X3
(1
9"
A S-361
B S-361
B S-361
'-4 " O
C
K3
4'
4"
'-4 " O
C
K1
4'
4"
'-1 1"
O C
K1
4'
'-1 1"
O C
K3
4'
4'
'-1 1"
O C
K5
4'
'-1 1"
O C
K3
'-1 1"
O C
K1
3'
4" 3'
5"
4'
8"
'-2 " O
C
K3
4'
'-1 0"
O C
K5
'-1 0"
O C
K3
4'
'-1 0"
O C
K1
4'
'-7 " O
C
K1
4'
7"
'-7 " O
C
K3
4'
7"
4'
7"
'-7 " O
C
K5
4'
7"
'-7 " O
C
K3
C S-361
D S-361
MATCHLINE - SEE S-133
M
AT
C H
LI
N
E -S
EE
S
-1
JST BRG EL
= 122'-2 3/4"
1.8k
1.8k
1.8k
1.8k
.0 k
.0 k
.0 k
.0 k
.0 k
JST BRG EL
= 120'-9 3/4"
W12X22
(POJ)
'-4 " O
C
K3
4'
4"
'-7 " O
C
K3
4'
7"
'-4 " O
C
K3
4'
4"
'-7 " O
C
K3
4'
7"
W12X22
(POJ)
'-4 " O
C
K5
4'
4"
'-4 " O
C
K3
4'
4"
'-4 " O
C
K1
4'
4"
18K3
34' - 0"
12' - 2"
TYP1
1.8k
12K1
3.0k
3.0k
3.0k
W
X3
(1
9"
W
X4
(1
9"
'-2 " O
C
K1
A S-363
C S-362
C S-362
A S-361
C S-363
B S-363
C S-363
B S-363
A S-364
A S-364
B S-364
SLOPE
DN
SLOPE
DN
TYP 1
1.8k
1.8k
1.8k
1.8k
1.8k
1.8k
1.8k
1.8k
1.8k
1.8k
1.8k9.
0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
14K3
14K3
INDICATES SPAN DIRECTION OF 1 1/2" METAL ROOF DECK.
SEE GENERAL NOTES FOR ATTACHMENT REQUIREMENTS.
LEGEND
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
R O
O F
FR
AM
IN
G
P
LA
N
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
C . G
IB
B
S
B.
R
EN
N
ER
D . D
IC
KE
Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
S-132
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"
PARTIAL ROOF FRAMING PLAN
GENERAL SHEET NOTES
1 REFER TO S-001 AND S-002 FOR GENERAL NOTES.
2 TOP OF STEEL ELEVATION IS REFERENCED FROM
FINISHED FLOOR ELEVATION 100'-0".
3 ALL DIMENSIONS ARE TO INSIDE FACE OF PRECAST.
4 REACTIONS SHOWN ARE FACTORED VERTICAL GRAVITY
LOADS. THESE REACTIONS DO NOT INCLUDE EFFECTS
FROM WIND.
SHEET KEYNOTES
1 KNEE BRACE BETWEEN JOIST BOTTOM CHORD AND BEAM
BOTTOM FLANGE. SEE TYPICAL JOIST KNEE BRACE
DETAIL ON S-511.
2 CANOPY, REFER TO ARCH DWGS.
3 ROOF HATCH OPENING. SEE TYPICAL ROOF
PENETRATION DETAIL ON SHEET S-511 FOR FRAMING
INFORMATION AND SHEET A-570 FOR ROOF HATCH
INFORMATION.
4 VAULT ROOF SLAB BELOW. REFER TO ENLARGED VAULT
ROOF SLAB FRAMING PLAN ON SHEET S-411.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
10/27/2023
BK
R
D D
W
2Q R
R
_P la ns _V ol 2-
F
G
H
J
W12X16
(POJ)
W12X22
(POJ)
W14X30
(POJ)
W12X22
(POJ)
22' - 6" 23' - 8" 21' - 10" 34' - 0" 23' - 2" 18' - 8" 5' - 4" 21' - 2"
W
X2
(1
9"
W
X2
(1
9"
W
X2
(1
8"
W
X2
(1
1"
W
X2
4'
-1
W
X2
(1
4"
W16X26
(POJ)
W
X3
(1
1/ 4"
W
X3
4'
-1
W
X3
(1
1"
W
X3
(1
8"
W
X3
(1
9"
W
X3
(1
9"
W12X22
(POJ)
W12X22
(POJ)
W14X30
(POJ)
W12X22
(POJ)
W
X2
(1
1/ 4"
W
X3
(1
1/ 4"
W
X3
(1
1/ 4"
W12X26
(POJ)
W12X22
(POJ)
W14X30
(POJ)
W12X22
(POJ)
W12X22
(POJ)
W
X2
(1
9"
W
X2
(1
9"
W
X2
(1
8"
W
X2
(1
1"
W
X2
(1
1/ 4"
W12X26
(POJ)
W12X22
(POJ)
W14X30
(POJ)
W12X22
(POJ)
W12X22
(POJ)
W
X3
(1
9"
W
X3
(1
9"
W
X3
(1
8"
W
X3
(1
1"
W
X3
(1
1/ 4"
W12X26
(POJ)
W12X22
(POJ)
W14X30
(POJ)
W12X22
(POJ)
W12X22
(POJ)
W
X3
(1
9"
W
X3
(1
9"
W
X3
(1
8"
W
X3
(1
1"
W
X3
(1
1/ 4"
A S-361
A S-361
B S-361
'-1 0"
O C
K1
4'
'-6 " O
C
K3
4'
4"
'-4 " O
C
K3
4'
4"
'-4 " O
C
K3
4'
2"
'-4 " O
C
K3
4'
4"
'-1 0"
O C
K3
4'
'-6 " O
C
K3
4'
4"
'-4 " O
C
K3
4'
4"
'-4 " O
C
K3
4'
2"
'-4 " O
C
K3
4'
4"
4'
'-1 0"
O C
K5
4'
4"
'-6 " O
C
K5
4'
4"
'-4 " O
C
K5
4'
2"
'-4 " O
C
K5
4'
4"
'-4 " O
C
K5
4'
'-1 0"
O C
K3
4'
4"
'-6 " O
C
K3
4'
4"
'-4 " O
C
K3
4'
2"
'-4 " O
C
K3
4'
4"
'-4 " O
C
K3
4'
'-1 0"
O C
K3
4'
4"
'-4 " O
C
K3
4'
4"
'-4 " O
C
K3
'-4 " O
C
K3
4'
4"
'-4 " O
C
K3
4'
2"
'-4 " O
C
K3
4'
4"
'-6 " O
C
K3
4'
4" 4'
'-1 0"
O C
K3
C S-361
D S-361
MATCHLINE - SEE S-132
M
AT
C H
LI
N
E -S
EE
S
-1
JST BRG EL
= 122'-2 3/4"
JST BRG EL
= 120'-9 3/4"
170' - 4"
4'
4"
'-4 " O
C
K3
4'
2"
'-4 " O
C
K3
4'
4"
'-4 " O
C
K3
4'
4"
'-6 " O
C
K3
4'
'-1 0"
O C
K3
3.5
3.7k
3.7k
3.7k
3.7k
2.9k
2.8k
3.2k
3.2k
3.2k
3.2k
3.0k
.0 k
.0 k
.0 k
.0 k
.0 k
.0 k
W12X22
(POJ)
'-4 " O
C
K3
4'
2"
'-6 " O
C
K3
4'
4"
18K3
MATCHLINE - SEE S-131
18K3
18K3
18K3
18K3
16K3
16K3
16K3
16K3
3.2k 20K3
A S-363
C S-362
B S-364
D S-363
A S-364
SLOPE
DN
SLOPE
DN
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
3.0k
2.8k
2.8k
2.8k
2.8k
2.8k
2.8k
2.8k
2.8k
2.8k
2.8k
2.8k
2.8k
2.8k
2.8k
2.8k
2.8k
2.8k
2.8k
2.8k
2.8k
INDICATES SPAN DIRECTION OF 1 1/2" METAL ROOF DECK.
SEE GENERAL NOTES FOR ATTACHMENT REQUIREMENTS.
LEGEND
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
KEYPLAN
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PA
R
TI
AL
R O
O F
FR
AM
IN
G
P
LA
N
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
C . G
IB
B
S
B.
R
EN
N
ER
D . D
IC
KE
Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
S-133
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"
PARTIAL ROOF FRAMING PLAN
GENERAL SHEET NOTES
1 REFER TO S-001 AND S-002 FOR GENERAL NOTES.
2 TOP OF STEEL ELEVATION IS REFERENCED FROM
FINISHED FLOOR ELEVATION 100'-0".
3 ALL DIMENSIONS ARE TO INSIDE FACE OF PRECAST.
4 REACTIONS SHOWN ARE FACTORED VERTICAL GRAVITY
LOADS. THESE REACTIONS DO NOT INCLUDE EFFECTS
FROM WIND.
SHEET KEYNOTES
1 CANOPY, REFER TO ARCH DWGS.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
10/27/2023
BK
R
D D
W
2Q R
R
_P la ns _V ol 2-
4 5 6
A
B
C
1/ 2"
1/ 2"
1"
1"
1"
1"
1'
0"
23' - 2" 18' - 8"
HSS12X4X1/4
SLOPED
HSS12X4X1/4
SLOPED
HSS12X4X1/4
SLOPED
HSS12X4X1/4
SLOPED
HSS12X4X1/4
SLOPED
HSS12X4X1/4
SLOPED
HSS12X4X1/4
SLOPED
HSS12X4X1/4
SLOPED
H
SS
X4
X1 /4
(1
H
SS
X4
X1 /4
(1
H
SS
X4
X1 /4
(1
H
SS
X4
X1 /4
(1
/4
H
SS
X4
X1 /4
(1
/4
H
SS
X4
X1 /4
(1
1"
H
SS
X4
X1 /4
(1
1"
H
SS
X4
X1 /4
(1
1"
H
SS
X4
X1 /4
(1
/4
A S-366
H
SS
X4
X1 /4
(1
H
SS
X4
X1 /4
(1
/4
H
SS
X4
X1 /4
(1
1"
H
SS
X4
X1 /4
(1
1"
H
SS
X4
X1 /4
(1
/4
H
SS
X4
X1 /4
(1
H
SS
X4
X1 /4
(1
H
SS
X4
X1 /4
(1
/4
H
SS
X4
X1 /4
(1
1"
6'
9"
'-9
/2 " O
C
H
SS
X4
X1 /4
5'
'-0 " O
C
H
SS
X4
X1 /4
5'
4"
'-4 " O
C
H
SS
X4
X1 /4
5'
4"
'-4 " O
C
H
SS
X4
X1 /4
5'
'-0 " O
C
H
SS
X4
X1 /4
6'
9"
'-9
/2 " O
C
H
SS
X4
X1 /4
A S-364
B S-364
B S-366
C S-366
5'
0"
'-0 " O
C
H
SS
X4
X1 /4
5'
0"
'-0 " O
C
H
SS
X4
X1 /4
HSS12X4X1/4
SLOPED
HSS12X4X1/4
SLOPED
D S-366
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
BI
D
O
PT
IO
N
SO
LA
R
P
AN
EL
S
U P
PO
R
T
FR
AM
IN
G
PL
AN
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
C . G
IB
B
S
B.
R
EN
N
ER
D . D
IC
KE
Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
S-141
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"
BID OPTION - SOLAR PANEL SUPPORT FRAMING PLAN
GENERAL SHEET NOTES
1 REFER TO S-001 AND S-002 FOR GENERAL NOTES.
2 TOP OF STEEL ELEVATION IS REFERENCED FROM
FINISHED FLOOR ELEVATION 100'-0".
3 ALL STEEL FOR SOLAR PANEL SUPPORT FRAMING SHALL
BE HOT-DIPPED GALVANIZED.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
BK
R
D D
10/27/2023
W
2Q R
R
_P la ns _V ol 2-
UP
S-212
S-211
S-213
S-212
1 2
5 6 8
23' - 8" 21' - 10" 34' - 0" 23' - 2" 24' - 0"
9 10
E
1"
0"
0"
AA
BB
CC
F
G
H
J
21' - 10" 34' - 0" 23' - 2" 18' - 8" 26' - 10" 22' - 10" 26' - 4"
S-211
S-211
S-213
S-213
1"
0"
S-212
S-212
D
5'
GRAPHIC SCALE: = 1'-0"
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
PR
EC
AS
T
C O
N C
R
ET
E W
AL
L
EL
E
VA
TI
O N
S
KE
Y
PL
AN
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
C . G
IB
B
S
B.
R
EN
N
ER
D . D
IC
KE
Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
S-200
D . H
EN
SL
EY
SCALE: 1/16" = 1'-0"
PRECAST CONCRETE WALL ELEVATIONS KEY PLAN
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
BK
R
D D
10/27/2023
W
2Q R
R
_P la ns _V ol 2-
LEVEL 1
100' - 0"
1234568 7
T.O. PRECAST
127' - 1"
172' - 0"
SEISMIC = 77 KIPS
WIND = 76 KIPS
LEVEL 1
100' - 0"
E F G H J
T.O. PRECAST
127' - 1"
SEISMIC = 164 KIPS
WIND = 113 KIPS
119' - 10"
LEVEL 1
100' - 0"
T.O. PRECAST
127' - 1"
77' - 10"
SEISMIC = 135 KIPS
WIND = 106 KIPS
UNFACTORED IN-PLANE SHEAR LOADS ACTING LATERALLY
IN EACH DIRECTION ALONG ROOF LINE. PRECAST
MANUFACTURER SHALL DISTRIBUTE LOADS TO
ASSOCIATED PIERS FOR PURPOSES OF DESIGN OF
PRECAST PANELS, AND TO DETERMINE QUANTITY AND
LOCATIONS OF CONNECTIONS OF PRECAST PANELS TO
SUPERSTRUCTURE AND FOUNDATION.
LEGEND
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
C O
N C
R E
TE
W
AL
L
EL
EV
AT
IO
N S
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
FO
R
T
BU
C H
AN
AN
, P U
ER
TO
R
IC
O
C . G
IB
B
S
B.
R
EN
N
ER
D . D
IC
KE
Y
O C
TO
B
ER
7, LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U I S
VI
LL
E, K
EN
TU
C
KY
S-211
D . H
EN
SL
EY
SCALE: 1/8" = 1'-0"S-200
ELEVATION1
SCALE: 1/8" = 1'-0"S-111
ELEVATION2
SCALE: 1/8" = 1'-0"S-113
ELEVATION3
GENERAL SHEET NOTES
1 PANEL SIZES SHOWN ARE CONCEPTUAL. ACTUAL SIZES
ARE THE RESPONSIBILITY OF THE PRECAST
MANUFACTURER.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
10/27/2023
BK
R
D D
W
2Q R
R
_P la ns _V ol 2-
8 9 10
T.O. PRECAST
127' - 1"
94' - 0"
SEISMIC = 53 KIPS
WIND = 56 KIPS
LEVEL 1
100' - 0"
T.O. PRECAST
127' - 1"
6' - 9"
SEISMIC = 4 KIPS
WIND = 2 KIPS
LEVEL 1
100' - 0"
A B C D
T.O. PRECAST
127' - 1"
111' - 0"
SEISMIC = 56 KIPS
WIND = 42 KIPS
LEVEL 1
100' - 0"
2 3 4 5 6
T.O. PRECAST
127' - 1"
121' - 10"
SEISMIC = 53 KIPS
WIND = 31 KIPS
UNFACTORED IN-PLANE SHEAR LOADS ACTING LATERALLY
IN EACH DIRECTION ALONG ROOF LINE. PRECAST
MANUFACTURER SHALL DISTRIBUTE LOADS TO
ASSOCIATED PIERS FOR PURPOSES OF DESIGN OF
PRECAST PANELS, AND TO DETERMINE QUANTITY AND
LOCATIONS OF CONNECTIONS OF PRECAST PANELS TO
SUPERSTRUCTURE AND FOUNDATION.
LEGEND
04'8' 16' 24'8'
GRAPHIC SCALE: 1/8" = 1'-0"GRAPHIC SCALE: = 1'-0"
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
SHEET ID
PR
O
JE
C
T N
O . 8
, P 2#
C
ER
TI
FI
ED
F
IN
AL
S U
BM
IT
TA
L
C O
N C
R E
TE
W
AL
L
EL
EV
AT
IO
N S
U .S
. A R
M Y
R
ES
ER
VE
C
EN
TE
R