This solicitation is for the renovation of the Rapid Reaction Laboratory at Wright-Patterson Air Force Base in Ohio. The estimated construction cost is between $5 million and $10 million. The work includes demolition of existing spaces, finishes, casework and equipment; and new finishes, casework, and mechanical systems. The NAICS code is 236220 for commercial and institutional building construction with a size standard of $45 million. Responses are due through the ProjNet system by the date specified. The Department of the Army Corps of Engineers Engineering District Louisville is the contracting agency. The procurement is full and open with a 10% price evaluation preference for HUBZone small businesses. On-site visits are available per FAR 52.236-27 ALT 1.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

6 7 8 11 12 13 14 15

L

J

G

38 39

40B

30A D02

D02D02

D01 D01

D13

D01

D04

D24

D24 D08

D10

D04

D20D20

D21

D22

D22

D23

D21

D10

D04

D08

D10

D08

D10

D08

D10

D08

D10

D10

D08 D10

D08 D10

D04

D22

D20

D01

D25

D08

D10

D01

D12

D08

D10

D26

D26

D27 D29

D04

D30

D12

D15

D04

D22

D20

D20

40C

D32

D22

D04D33

D04

D04

D04

D04

D04

D22

D22

D17

D10

D32

D32

D04

D04

D04

D16

D16

D17

D38

D04

D19

D37

D17D01

D29

D08

D10

D35

D41

D08 1

D08

3/4" FIRE-RETARDANT PLYWOOD

ON 2X4 FIRE-RETARDANT WOOD

STUDS AT 16" ON CENTER AND

SECURED TO EXISTING FLOOR

AND STRUCTURE ABOVE.

APPROXIMATELY 8'-0" X 12'-0"

FOOTPRINT, COORDINATE FINAL

SIZE WITH DEPARTMENT

PERSONNEL.

TEMPORARY PROTECTION AT UT TANK

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

IT

R

R E

V

IE

W B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R E

N O

V A

T E

R E

S E

A R

C H

L A

B F

O R

R A

P

ID

R E

A C

T

IO

N

W P

A F

B B

U

IL

D

IN

G

W R

IG

H

T P

A T

T E

R S

O N

A F

B O

H

IO

Z H

T V

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B

R O

A D

W A

Y S

T R

E E

T

C

IN

C

IN

N A

T I, O

H

IO

KEY PLAN

SEAL 12-22-22

AD102

D E

M O

L

IT

IO

N

F L O

O R

P L A

N S

J P

E S

S E

L L

M A

L B

E R

S

G H

U T

Z E

L

R S

C H

M

IT

Z

-1

-2

CERTIFIED FINAL - MAR 16, 2023

1/8" = 1'-0"AD102

01 FIRST FLOOR DEMOLITION PLAN

N

16'4' 8'

SCALE: 1/8"=1'-0"

DRAWING NOTES

D35 LOOSE EQUIPMENT AND CHEMICALS TO BE

REMOVED IN ROOM 40C PRIOR TO

CONSTRUBTION COMMENCING

D37 REMOVE EXISTING CAPTURE HOOD - DUST

COLLECTION SYSTEM SERVING LAB ABOVE

IS TO REMAIN

D38 REMOVE EXISTING FUME HOOD, REFER TO

PLUMBING AND MECHANICAL DEMOLITION

FOR UTILITY CONNECTIONS. CONTRACTOR

TO DISCONNECT EXISTING FPI LINE

EQUIPMENT AND RE-INSTALL IN NEW

LOCATION

D41 COORDINATE WITH USER TO REMOVE

SUPPLIES FROM ROOM PRIOR TO

RENOVATION OF THIS SPACE

D21 SALVAGE, STORE AND REINSTALL EXISTING

CASEWORK. SALVAGE, REFINISH AND

REINSTALL EXISTING COUNTERTOP.

REMOVE EXISTING SHELF. SALVAGE,

REFINISH AND REINSTALL EXISTING SHELF

ACCESSORIES

D22 REMOVE EXISTING WALL CABINETS

D23 SALVAGE, STORE AND REINSTALL EXISTING

STORAGE

D24 EXISTING TANK AND CONTROL STATION TO

REMAIN. PROTECT EQUIPMENT WITH

TEMPORARY ENCLOSURE DESCRIBED ON

SHEET AD102

D25 REMOVE CMU AS REQUIRED TO INSTALL

NEW DOOR. COORDINATE WITH NEW WORK

D26 SALVAGE, STORE AND REINSTALL EXISTING

BENCH

D27 SALVAGE, STORE AND REINSTALL EXISTING

REFRIGERATOR

D29 EXISTING MPI LINE TO REMAIN IN LAB.

DEPARTMENT PERSONNEL TO MOVE WHEN

CONSTRUCTION ACTIVITY WARRANTS

D30 SALVAGE, STORE AND REINSTALL EXISTING

WORKSTATION

D32 REMOVE EXISTING METAL CHASE AND

UTILITIES, REFER TO PLUMBING DRAWINGS

D33 REMOVE EXISTING PASS-THRU AND

ACCESSORIES - CONTRACTOR IS

RESPONSIBLE FOR DETERMINING IF

HAZARDOUS MATERIALS ARE PRESENT

PRIOR TO REMOVAL

D01 REMOVE EXISTING DOOR, FRAME AND

ASSOCIATED HARDWARE AND ACCESSORIES

D02 REMOVE EXISTING CMU PARTITION

D04 REMOVE EXISTING LAB CASEWORK AND

ASSOCIATED ACCESSORIES. REFER TO MEP

DRAWINGS FOR REQUIREMENTS AT

UTILITIES

D08 REMOVE EXISTING FLOORING, BASE AND

ACCESSORIES. PREPARE SURFACE FOR

NEW FLOORING. REFER TO INTERIOR

DRAWINGS OF NEW FLOORING FOR SCOPE

OF FLOORING DEMOLITION

D10 PATCH OPENINGS, EXISTING AND AS A

RESULT OF DEMOLITION, IN WALLS,

CEILINGS AND FLOORS IN PREPARATION

FOR NEW FINISHES

D12 REMOVE EXISTING DOOR AND ASSOCIATED

HARDWARE AND ACCESSORIES. EXISTING

FRAME TO REMAIN FOR REUSE

D13 REMOVE EXISTING ACCORDION DOOR AND

ASSOCIATED HARDWARE AND

ACCESSORIES. REFER TO PHASING PLAN

FOR TEMPORARY DUST PARTITION

D15 REMOVE EXISTING DOOR FRAME AND

ACCESSORIES

D16 REMOVE EXISTING SHELVING AND

ACCESSORIES

D17 REMOVE EXISTING FUME HOOD, REFER TO

PLUMBING AND MECHANICAL DEMOLITION

FOR UTILITY CONNECTIONS

D19 SALVAGE, STORE AND REINSTALL EXISTING

WALL CABINETRY

D20 REMOVE EXISTING FURNITURE

LINEWORK LEGEND

EXISTING

DEMOLITION

A m e n d m e n t

-0

-2

W

2Q R

R

_P la ns -0

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

8 9 10

L

J

G

D01

D02

D10

D10

D12

D12

D04

D22

D12

D32

D04

D04

D04

D04

D04 D04

D17

D08

D08 1

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

IT

R

R E

V

IE

W B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R E

N O

V A

T E

R E

S E

A R

C H

L A

B F

O R

R A

P

ID

R E

A C

T

IO

N

W P

A F

B B

U

IL

D

IN

G

W R

IG

H

T P

A T

T E

R S

O N

A F

B O

H

IO

Z H

T V

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B

R O

A D

W A

Y S

T R

E E

T

C

IN

C

IN

N A

T I, O

H

IO

KEY PLAN

SEAL 12-22-22

AD103

D E

M O

L

IT

IO

N

F L O

O R

P L A

N S

J P

E S

S E

L L

M A

L B

E R

S

G H

U T

Z E

L

R S

C H

M

IT

Z

-1

-2

CERTIFIED FINAL - MAR 16, 2023

1/8" = 1'-0"AD103

01 SECOND FLOOR DEMOLITION PLAN

N

16'4' 8'

SCALE: 1/8"=1'-0"

DRAWING NOTES

D01 REMOVE EXISTING DOOR, FRAME AND

ASSOCIATED HARDWARE AND ACCESSORIES

D02 REMOVE EXISTING CMU PARTITION

D04 REMOVE EXISTING LAB CASEWORK AND

ASSOCIATED ACCESSORIES. REFER TO MEP

DRAWINGS FOR REQUIREMENTS AT

UTILITIES

D08 REMOVE EXISTING FLOORING, BASE AND

ACCESSORIES. PREPARE SURFACE FOR

NEW FLOORING. REFER TO INTERIOR

DRAWINGS OF NEW FLOORING FOR SCOPE

OF FLOORING DEMOLITION

D10 PATCH OPENINGS, EXISTING AND AS A

RESULT OF DEMOLITION, IN WALLS,

CEILINGS AND FLOORS IN PREPARATION

FOR NEW FINISHES

D12 REMOVE EXISTING DOOR AND ASSOCIATED

HARDWARE AND ACCESSORIES. EXISTING

FRAME TO REMAIN FOR REUSE

D17 REMOVE EXISTING FUME HOOD, REFER TO

PLUMBING AND MECHANICAL DEMOLITION

FOR UTILITY CONNECTIONS

D22 REMOVE EXISTING WALL CABINETS

D32 REMOVE EXISTING METAL CHASE AND

UTILITIES, REFER TO PLUMBING DRAWINGS

LINEWORK LEGEND

EXISTING

DEMOLITION

A m e n d m e n t

-0

-2

W

2Q R

R

_P la ns -0

DN

DN

UP

DN

UP

DNUP

ELEV

FAILURE

ANALYSIS

LAB

ENVIRONMENTAL

TEST LAB

THERMOGRAPHY/

SHEAROGRAPHY

UT/EC

FPI/MPI

RADIOGRAPHY

40 X RAY

40B

UT/EC

FAILURE

ANALYSIS

LAB

STORAGE

FAILURE

ANALYSIS

LAB

FAILURE

ANALYSIS

LAB

LAB

30A

F01 F01

F01

F01 F01 F01F01

F01F01F01

F02 F02

F02

F02

F02

F02

F02

F02

F02

F02 F02

F02

F05

F05

UTILITY

SHAFT 1

UTILITY

SHAFT 3

UTILITY

SHAFT 4

FLOORING LEGEND

EPOXY FLOOR (EPX-1)

NOT IN SCOPE

EPOXY FLOOR (EPX-2)

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

IT

R

R E

V

IE

W B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R E

N O

V A

T E

R E

S E

A R

C H

L A

B F

O R

R A

P

ID

R E

A C

T

IO

N

W P

A F

B B

U

IL

D

IN

G

W R

IG

H

T P

A T

T E

R S

O N

A F

B O

H

IO

Z H

T V

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B

R O

A D

W A

Y S

T R

E E

T C

IN

C

IN

N

A T

I, O

H

IO

KEY PLAN

SEAL 12-22-22

I-102

F

IR

S T

F L O

O R

F

IN

IS

H

P L A

N

M K

E L L Y

B G

IL

L E

S

G H

U T

Z E

L

M K

E L L E

Y

-1

-2

CERTIFIED FINAL - MAR 16, 2023

GENERAL NOTES

DRAWING NOTES

1/8" = 1'-0"I-102

1 FIRST FLOOR FINISH PLAN

N 16'4' 8'

SCALE: 1/8"=1'-0"

F01 PROVIDE APPROPRIATE FLOORING TRANSITION IF ADJACENT FLOORING IS

NOT THE SAME. REFER TO INTERIOR FINISH SCHEDULE FOR FLOORING

FINISHES AND TYPICAL TRANSITION DETAILS FOR SPECIFIED FLOORING

TRANSITION.

F02 REFERENCE ENLARGED PLANS, Q-300 SERIES, AND Q-400 ELEVATIONS FOR

CASEWORK DETAILS.

F05 NO NEW FLOORING IN THIS ROOM.

A REFERENCE SHEET I-001 FOR FINISH SPECIFICATIONS.

B REFERENCE SHEET I-601 FOR FINISH SCHEDULE.

C REFERENCE SHEET I-501 FOR DETAILS.

A m e n d m e n t

-0

-2

W

2Q R

R

_P la ns -0

T S

P

T S P

"ø

SG-2

315 CFM

CONNECT TO EXISTING DUST

COLLECTOR DROP (TYP)

NEW CONNECTION TO

EXISTING DUST

COLLECTOR

LAB

G18A

LAB

G18

(TYP OF 6)

SG-1

300 CFM

M04

NIC

NIC

M05

4" EA

RG-2

315 CFM

M06

4" EA 4" EA

E A

4" EA

E A

EXHAUST HOOD FOR

AUTOCLAVE.

BALANCE TO 700 CFM

#127

24"x12" EA

8"ø EA UP

18" SA UP

7'-4" AFF BOD

CV-1

CV-2

M28M28

M28M28

12"ø16"ø

6 7 8 9 10

G

Fb

8.77.3

F.9

F.1

F.3

7.8 8.5

G.2

G.4

8.8 9.4

OFFICE

G17B

#113

#121

#121A #123

E A

M36

M37

M38 M38

CV-1 CV-2

(TYP OF 4)

SG-2

315 CFM

"x

RG-1

30"x14"

MEZZANINE

G18M

30"x6"

24"x18"

NIC

RG-2

315 CFM

24"x24" M06

M15 M15

M02

4" FLAMMABLE

CABINET VENT

8"ø EA DN

CH-1

24"x6" SA

"ø

E A

6'-10"

AFF

BOD

M29

BALANCE TO

300 CFM

SG-1

300 CFM

6 7 8 9 10

J

G

Fb

8.77.3 7.8 8.5 8.8 9.4

6"ø

ROUTE DUCTWORK

AS HIGH AS POSSIBLE

ROUTE DUCTWORK

AS HIGH AS POSSIBLE

M33

#128

#109

M04

M35

16"x6"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

IT

R

R E

V

IE

W B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R E

N O

V A

T E

R E

S E

A R

C H

L A

B F

O R

R A

P

ID

R E

A C

T

IO

N

W P

A F

B B

U

IL

D

IN

G

W R

IG

H

T P

A T

T E

R S

O N

A F

B O

H

IO

Z H

T V

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B

R O

A D

W A

Y S

T R

E E

T C

IN

C

IN

N

A T

I, O

H

IO

KEY PLAN

SEAL

M-101

G R

O U

N D

F L O

O R

M E

C H

A N

IC

A

L P

L A

N

C B

R A

N S

C U

M

J N

A D

E R

G H

U T

Z E

L

R B

E A

U F

A

IT

-1

-2

CERTIFIED FINAL - MAR 16, 2023

DRAWING NOTES

LINEWORK LEGEND

EXISTING

NEW WORK

M02 10"Ø EA UP TO NEW LEF-2-G18 ON ROOF. REFER

TO A-601 AND LIFE SAFETY PLANS FOR UTILITY

SHAFT PENETRATION INFORMATION.

M04 16X12 SA UP AND DOWN TO SG-2.

M05 18X16 SA UP TO MEZZANINE.

M06 12X16 RA UP TO MEZZANINE.

M15 RECONNECT EXISTING HWS & HWR TO NEW CV.

REFER TO DETAIL 01 / M-501.

M28 FOR RX-NET MONITORING PURPOSES ONLY.

M29 PROVIDE FIRE RESISTANT DUCT WRAP FOR 10FT

ON EACH SIDE OF FIRE BARRIER. REFER TO LIFE

SAFETY PLANS AND A-601 FOR FIRE BARRIER

LOCATIONS.

M33 EXISTING 790 CFM SUPPLY GRILLE TO REMAIN.

M35 4" VENT THRU WALL. PROVIDE WITH BIRD

SCREEN.

M36 6" VENT THRU WALL. PROVIDE WITH BIRD

SCREEN.

M37 3" EA TO AUTOCLAVE.

M38 NEW DUST COLLECTION DUCTWORK. PROVIDE

REINFORCED SPIRAL TUBING. PROVIDE

ASSOCIATED REINFORCED SPIRAL TUBING

FITTINGS, ELBOWS, AND INSTALLATION

HARDWARE. TUBING SHALL BE AT LEAST 0.06 IN

THICK. INSTALL PER MANUFACTURER'S

RECOMMENDATIONS. PROVIDE DUSTCONTROL OR

SIMILAR PRODUCT.

1/8" = 1'-0"M-101

01 GROUND FLOOR MECHANICAL PLAN

N

16'4' 8'

SCALE: 1/8"=1'-0"

1/8" = 1'-0"M-101

02 MEZZANINE MECHANICAL PLAN

A m m e n d m e n t

-0

-2

1 1

Mar 16, 2023

W

2Q R

R

_P la ns -0

682002_AD102 - DEMOLITION FLOOR PLANS
682002_AD103 - DEMOLITION FLOOR PLANS
682002_I-102 - FIRST FLOOR FINISH PLAN
M-101 - GROUND FLOOR MECHANICAL PLAN

File details come from the government source that posted it. Updated .