W912QR23R0033_Plans-0000.pdf

PDF 23 MB Posted

Attached to
SRM WPAFB AFRL Rapid Reaction Lab
Solicitation number
W912QR23R0033
Issued by

About this file

This document provides details on a federal contract solicitation for renovation work. The solicitation seeks bids for renovating the Rapid Reaction Laboratory at Wright-Patterson Air Force Base in Ohio, with an estimated construction cost between $5 million and $10 million. The work falls under NAICS code 236220 for commercial and institutional building construction. Bidders must be correctly classified as small or other than small businesses under this NAICS code in the System for Award Management. This is a full and open procurement requiring the HUBZone 10% price evaluation. Technical questions should be submitted through the ProjNet website. The soliciting agency is the Department of the Army Corps of Engineers Engineering District Louisville.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BUILDING 20652

PROJECT

LOCATION

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

IT

R

R E

V

IE

W B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

US Army Corps of Engineers ®

CONTRACT NO.:

ISSUE DATE:

TASK ORDER:

PROJECT NO.:

M A

R K

D E

S C

R

IP

T

IO

N

R E

N O

V A

T E

R E

S E

A R

C H

L A

B F

O R

R A

P

ID

R E

A C

T

IO

N

W P

A F

B B

U

IL

D

IN

G

W R

IG

H

T P

A T

T E

R S

O N

A F

B O

H

IO

Z H

T V

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B

R O

A D

W A

Y S

T R

E E

T C

IN

C

IN

N

A T

I, O

H

IO

LOUISVILLE DISTRICT

W912QR-21-F-0205

W912QR-19-D-0041

MARCH 16, 2023

ZHTV200015

WRIGHT-PATTERSON AFB, OHIO

CERTIFIED FINAL SUBMITTAL - FY 23

FOR OFFICIAL USE ONLY

P2 NO.: 495449

12-22-22

G-000

C O

V E

R S

H E

E T

J P

E S

S E

L L

M A

L B

E R

S

G H

U T

Z E

L

R S

C H

M

IT

Z

-1

-2

CERTIFIED FINAL - MAR 16, 2023

RENOVATE RESEARCH LAB FOR RAPID REACTION, F/20652

OHIO

DAYTON

WRIGHT

PATTERSON

AFB

MONTGOMERY

COUNTY

GREENE COUNTY

WRIGHT PATTERSON AIR FORCE BASE

700 Broadway Street Cincinnati, Ohio 45202

ARCHITECTURE, INTERIORS, STRUCTURAL,

MECHANICAL, PLUMBING

LAB PLANNING ELECTRICAL AND TELECOMMUNICATIONS FIRE PROTECTION AND LIFE SAFETY

W

2Q R

R

_P la ns -0

03 May 2023

W912QR23R0033

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

IT

R

R E

V

IE

W B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R E

N O

V A

T E

R E

S E

A R

C H

L A

B F

O R

R A

P

ID

R E

A C

T

IO

N

W P

A F

B B

U

IL

D

IN

G

W R

IG

H

T P

A T

T E

R S

O N

A F

B O

H

IO

Z H

T V

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B

R O

A D

W A

Y S

T R

E E

T

C

IN

C

IN

N A

T I, O

H

IO

SEAL 12-22-22

G-001

D R

A W

IN

G

I N

D E

X

J P

E S

S E

L L

M A

L B

E R

S

G H

U T

Z E

L

R S

C H

M

IT

Z

-1

-2

CERTIFIED FINAL - MAR 16, 2023

DRAWING INDEX

NO TITLE

CURRENT

ISSUE

ELECTRICAL

E-000 ELECTRICAL LEGEND

ED101 GROUND FLOOR ELECTRICAL DEMOLITION PLAN

ED102 FIRST FLOOR ELECTRICAL DEMOLITION PLAN

ED103 SECOND FLOOR ELECTRICAL DEMOLITION PLAN

EG104 ROOF GROUNDING PLAN

EL101 GROUND FLOOR LIGHTING PLAN

EL102 FIRST FLOOR LIGHTING PLAN

EL103 SECOND FLOOR LIGHTING PLAN

EP100 SITE POWER PLAN

EP101 GROUND FLOOR POWER PLAN

EP102 FIRST FLOOR POWER PLAN

EP103 SECOND FLOOR POWER PLAN

EP104 ROOF POWER PLAN

E-401 ENLARGED PLANS - LAB G18, G18A, G18M

E-402 ENLARGED PLANS - LAB 19, 20

E-403 ENLARGED PLANS - LAB 27, 28, 29

E-404 ENLARGED PLANS - LAB 30, 30A, 31

E-405 ENLARGED PLANS - LAB 38, 39

E-406 ENLARGED PLANS - LAB 40, 49

E-407 ENLARGED PLANS - LAB 117. 145

E-501 ELECTRICAL DETAILS

E-601 ELECTRICAL SCHEDULES

E-701 ELECTRICAL RISER DIAGRAM

E-801 PANEL SCHEDULES - LABS 19 & 20

E-802 PANEL SCHEDULES - LABS 27 & 28

E-803 PANEL SCHEDULES - LABS 30, 30A, 31

E-804 PANEL SCHEDULES - LABS 38 & 39

E-805 PANEL SCHEDULES - LAB 40

E-806 PANEL SCHEDULES - LAB 49 & 117

E-807 PANEL SCHEDULES - LAB 145

E-808 PANEL SCHEDULES - LAB G18, G18A, G18M

E-809 PANEL SCHEDULES - LIGHTING

FIRE ALARM

FA101 GROUND FLOOR AND MEZZANINE PLAN - FIRE ALARM

FA102 FIRST FLOOR PLAN - FIRE ALARM

FA103 SECOND FLOOR PLAN - FIRE ALARM

TELECOMMUNICATIONS

T-000 TELECOM LEGEND

TD101 GROUND FLOOR TELECOM DEMOLITION PLAN

TD102 FIRST FLOOR TELECOM DEMOLITION PLAN

TD103 SECOND FLOOR TELECOM DEMOLITION PLAN

T-101 GROUND FLOOR TELECOM PLAN

T-102 FIRST FLOOR TELECOM PLAN

T-103 SECOND FLOOR TELECOM PLAN

T-501 TELECOM DETAILS

T-502 TELECOM DETAILS

DRAWING INDEX

NO TITLE

CURRENT

ISSUE

EQUIPMENT

Q-001 LAB EQUIPMENT LEGEND & GENERAL NOTES

Q-101 GROUND & MEZZ FLOOR EQUIPMENT PLAN

Q-102 FIRST FLOOR EQUIPMENT PLAN

Q-103 SECOND FLOOR EQUIPMENT PLAN

Q-201 GROUND FLOOR NEW EQUIPMENT PLAN

Q-202 FIRST FLOOR NEW EQUIPMENT PLAN

Q-203 FIRST FLOOR NEW EQUIPMENT PLAN

Q-204 FIRST FLOOR NEW EQUIPMENT PLAN

Q-205 FIRST FLOOR NEW EQUIPMENT PLAN

Q-206 FIRST FLOOR NEW EQUIPMENT PLAN

Q-207 SECOND FLOOR NEW EQUIPMENT PLAN

Q-301 ENLARGED GROUND PLANS

Q-302 ENLARGED FIRST FLOOR

Q-303 ENLARGED FIRST FLOOR

Q-304 ENLARGED SECOND FLOOR PLAN

Q-401 INTERIOR ELEVATIONS

Q-402 INTERIOR ELEVATIONS

Q-403 INTERIOR ELEVATIONS

Q-404 INTERIOR ELEVATIONS

Q-405 INTERIOR ELEVATIONS

Q-501 CASEWORK SECTIONS

FIRE PROTECTION

FX101 GROUND AND MEZZANINE FLOOR PLAN - FIRE

PROTECTION

FX102 FIRST FLOOR PLAN - FIRE PROTECTION

FX103 SECOND FLOOR PLAN - FIRE PROTECTION

PLUMBING

P-001 ABBREVIATIONS AND SYMBOLS

P-002 GENERAL NOTES

PD101 GROUND AND MEZZANINE DEMOLITION PIPING PLANS

PD102 FIRST FLOOR DEMOLITION PIPING PLAN - NORTH

PD103 FIRST FLOOR DEMOLITION PIPING PLAN - SOUTH

PD104 SECOND FLOOR DEMOLITION PIPING PLAN

P-101 GROUND AND MEZZANINE PIPING PLANS

P-102 FIRST FLOOR PIPING PLAN - NORTH

P-103 FIRST FLOOR PIPING PLAN - SOUTH

P-104 LAB EQUIPMENT SCHEDULES

P-105 SECOND FLOOR PIPING PLAN

P-111 NITROGEN PIPING PLAN

P-301 SECTIONS

P-501 DETAILS

P-502 DETAILS

P-601 SCHEDULES

MECHANICAL

M-001 ABBREVIATIONS & SYMBOLS

M-002 GENERAL NOTES

MD101 GROUND FLOOR DEMOLITION MECHANICAL PLAN

MD102 FIRST FLOOR DEMOLITION MECHANICAL PLAN

MD103 SECOND FLOOR DEMOLITION MECHANICAL PLAN

MD104 ROOF DEMOLITION MECHANICAL PLAN

M-101 GROUND FLOOR MECHANICAL PLAN

M-102 FIRST FLOOR MECHANICAL PLAN

M-103 SECOND FLOOR MECHANICAL PLAN

M-104 ROOF MECHANICAL PLAN

M-501 DETAILS

M-502 DETAILS

M-601 SCHEDULES

M-701 CONTROLS

M-801 AIR FLOW DIAGRAMS

DRAWING INDEX

NO TITLE

CURRENT

ISSUE

GENERAL

G-000 COVER SHEET

G-001 DRAWING INDEX

G-002 CODE SUMMARY

G-003 SITE NOTES AND LOGISTICS

G-004 BASE BID AND BID OPTIONS

G-005 BASE BID AND BID OPTIONS

G-011 GROUND FLOOR PHASING PLAN - PHASE 1

G-012 FIRST FLOOR PHASING PLAN - PHASE 1

G-013 SECOND FLOOR PHASING PLAN - PHASE 1

G-021 FIRST FLOOR PHASING PLAN - PHASE 2

G-022 FIRST FLOOR PHASING PLAN - PHASE 2A

LIFE SAFETY

G-101 GROUND FLOOR AND MEZZANINE PLAN - LIFE SAFETY

G-102 FIRST FLOOR PLAN - LIFE SAFETY

G-103 SECOND FLOOR PLAN - LIFE SAFETY

G-104 FIRE PROTECTION LIFE SAFETY WORKSHEET

HAZARDOUS MATERIALS

H-101 HAZARDOUS MATERIALS - GROUND FLOOR

H-102 HAZARDOUS MATERIALS - FIRST FLOOR

H-103 HAZARDOUS MATERIALS - SECOND FLOOR

STRUCTURAL

S-001 GENERAL NOTES

S-002 GENERAL NOTES AND DESIGN DATA

S-003 SPECIAL INSPECTION REQUIREMENTS

S-004 SPECIAL INSPECTION REQUIREMENTS

S-101 FOUNDATION AND MEZZANINE FRAMING PLANS

S-102 MEZZANINE FRAMING PLAN

S-103 FIRST AND SECOND FLOOR FRAMING PLANS

S-501 SECTIONS AND DETAILS

S-502 SECTIONS AND DETAILS

S-701 RECORD DRAWING 1975

S-702 RECORD DRAWING 1975

S-703 RECORD DRAWING 1975

S-704 RECORD DRAWING 1975

ARCHITECTURE

A-001 SYMBOLS & ABBREVIATIONS

A-011 GROUND FLOOR EXISTING LAB

A-012 FIRST FLOOR EXISTING LAB

A-013 SECOND FLOOR EXISTING LAB

AD101 DEMOLITION FLOOR PLANS

AD102 DEMOLITION FLOOR PLANS

AD103 DEMOLITION FLOOR PLANS

AD111 DEMOLITION CEILING PLANS

A-101 GROUND FLOOR AND MEZZANINE PLAN

A-102 FIRST FLOOR PLAN

A-103 SECOND FLOOR PLAN

A-104 ROOF PLAN

A-111 GROUND FLOOR AND MEZZANINE CEILING PLAN

A-112 FIRST AND SECOND FLOOR CEILING PLANS

A-301 WALL SECTIONS

A-501 PARTITION TYPES AND INTERIOR DETAILS

A-510 CEILING DETAILS

A-601 DOOR SCHEDULE AND DETAILS AND FIRE STOPPING

SCHEDULE

A-701 STAIR PLANS, SECTIONS, AND DETAILS

INTERIORS

I-001 INTERIOR SPECIFICATIONS

I-101 GROUND FLOOR AND MEZZANINE FINISH PLAN

I-102 FIRST FLOOR FINISH PLAN

I-103 SECOND FLOOR FINISH PLAN

I-112 FIRST FLOOR FURNITURE PLAN

I-121 GROUND FLOOR SIGNAGE PLAN

I-122 FIRST FLOOR SIGNAGE FLOOR PLAN

I-123 SECOND FLOOR SIGNAGE FLOOR PLAN

I-501 DETAILS

I-511 SIGNAGE DETAILS

I-601 FINISH SCHEDULE

I-621 SIGNAGE SCHEDULE

W

2Q R

R

_P la ns -0

CODES, STANDARDS AND REGULATIONS

- INTERNATIONAL BUILDING CODE® (IBC), 2018, FOR CONSTRUCTION TYPE AND FIRE RESISTANCE RATING, OCCUPANCY -

SEPARATION, ALLOWABLE FLOOR AREA, BUILDING HEIGHT LIMITATIONS AND BUILDING SEPARATION DISTANCE

REQUIREMENTS, EXCEPT AS MODIFIED BY UFC 3-600-01

- NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2022 EDITION

- NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2022 EDITION

- NFPA 45 STANDARD ON FIRE PROTECTION FOR LABORATORIES USING CHEMICALS, 2019 EDITION

- NFPA 70 NATIONAL ELECTRICAL CODE®, 2020 EDITION

- NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE®, 2022 EDITION

- NFPA 80 STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES, 2022 EDITION

- NFPA 90A STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS, 2021

EDITION

- NFPA 101 LIFE SAFETY CODE®, 2021 EDITION

- UFC 3-600-01 DESIGN: FIRE PROTECTION ENGINEERING FOR FACILITIES, 8 AUGUST, 2016, CHANGE 6 (6 MAY

2021)

- UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 12 DECEMBER 2018, CHANGE 1 (19

AUGUST 2020)

- UFC 4-021-01 DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, 9 APRIL, 2008, CHANGE 1 (1 JANUARY 2010)

BUILDING DESCRIPTION

BUILDING 20652 IS A THREE-STORY EXISTING BUILDING THAT IS CURRENTLY USED AS LABORATORY AND OFFICES. RENOVATIONS ARE PROPOSED WITHIN A FEW LABORATORY SPACES. THE PROJECT IS CONSIDERED REHABILITATION IN ACCORDANCE WITH UFC 3-600-01. THE ENTIRE BUILDING MUST COMPLY WITH THE EXISTING OCCUPANCY REQUIREMENTS FROM NFPA 101. NEW WORK MUST COMPLY WITH THE REQUIREMENTS FOR

REHABILITATION. THE USE WILL NOT CHANGE AS PART OF THIS PROJECT.

BUILDING CODE ANALYSIS

AS AN EXISTING BUILDING WITH NO PROPOSED OCCUPANCY CHANGES, A BUILDING CODE ANALYSIS IS NOT REQUIRED. AS THE EXISTING CONSTRUCTION TYPE IS NONCOMBUSTIBLE, NEW MATERIALS UTILIZED IN WALL TYPES, ETC., MUST BE IN ACCORDANCE WITH THE IBC FOR TYPE II CONSTRUCTION. THE NEW MEZZANINE AREAS MUST COMPLY WITH THE REQUIREMENTS FOR NEW CONSTRUCTION WHICH WOULD INCLUDE MEZZANINE AREA LIMITATIONS. MEZZANINES ARE NOT CONSIDERED FLOORS SO THERE ARE NO REQUIREMENTS FOR THE MEZZANINE CONSTRUCTION BEYOND LIMITING MATERIALS TO NONCOMBUSTIBLE. MEANS OF EGRESS

REQUIREMENTS FOR THE MEZZANINE ARE DISCUSSED IN THE MEANS OF EGRESS SECTION.

MEZZANINE ABOVE G18A AND AUTOCLAVE (MEZZANINE AREA A)

ROOM AREA: 4,805 SQUARE FEET (LAB G17, ADJACENT TO G18)

MEZZANINE AREA LIMIT: 2,402 SQUARE FEET (50% OF ROOM AREA)

1,049 SQUARE FEET

(ENCLOSED MEZZANINE LIMITED TO AN OCCUPANT

LOAD OF 10 OR LESS)

ACTUAL MEZZANINE AREA: 282 SQUARE FEET (INCLUDES EXISTING STORAGE

MEZZANINE)

G18M (MEZZANINE AREA B)

ROOM AREA: 1,224 SQUARE FEET (LAB G18)

MEZZANINE AREA LIMIT: 612 SQUARE FEET (50% OF ROOM AREA)

ACTUAL MEZZANINE AREA: 608 SQUARE FEET

OCCUPANCY CLASSIFICATION

NON-INSTRUCTIONAL LABORATORIES ARE CLASSIFIED AS INDUSTRIAL USE PER NFPA 101. IN ADDITION, THERE ARE NO CHANGES PROPOSED RELATED TO LABORATORY UNITS OR INTERIOR SEPARATIONS. BASED UPON THE ABSENCE OF FIRE RESISTANCE RATED DOORS TO THE CORRIDOR, IT IS BELIEVED THAT LABORATORY UNITS ARE DEFINED BY FLOOR. EACH FLOOR IS APPROXIMATELY 17,400 SQUARE FEET SO THE LABORATORY UNIT MAXIMUMS ARE THE MOST RESTRICTIVE QUANTITY. THE ASSOCIATED QUANTITY LIMITS FOR CLASS C AND D

LABORATORY UNITS PER NFPA 45 ARE PROVIDED BELOW.:

BASED UPON THE INFORMATION PROVIDED BY THE USER IN AUGUST 2022 (SEE TABLE BELOW) THE QUANTITIES INDICATE CLASSIFICATION AS CLASS D LABORATORY UNITS. TO PROVIDE FLEXIBILITY IN THE FUTURE AND TO ACCOUNT FOR QUANTITIES IN THE 1,905-ITEM INVENTORY THAT MAY HAVE BEEN MISCATEGORIZED OR INCLUDED

UNDER A DIFFERENT CLASSIFICATION, A CLASS C LABORATORY UNIT HAS BEEN UTILIZED.

LAB UNIT CLASS

C (LOW FIRE

HAZARD )

FLAMMABLE AND

COMBUSTIBLE

LIQUID CLASS

QUANTITES IN USE

(OR NOT IN SAFETY CABINET)

QUANTITES IN USE

AND STORAGE

I

I, II, AND IIIA

MAX QUANTITY

PER 100 SF

MAX QUANTITY

PER LAB UNIT

MAX QUANTITY

PER 100 SF

MAX QUANTITY

PER LAB UNIT

4 GALLONS

2 GALLONS

200 GALLONS

150 GALLONS

8 GALLONS

4 GALLONS

400 GALLONS

300 GALLONS

PASSIVE FIRE PROTECTION

THE EXISTING MECHANICAL CHASES ARE REQUIRED TO HAVE A 1-HOUR FIRE RESISTANCE RATING. THERE ARE NO OTHER AREAS WITHIN THE PROJECT AREA THAT ARE REQUIRED TO HAVE A FIRE RESISTANCE RATED SEPARATION. THE SCOPE OF WORK INCLUDES CORRECTION OF EXISTING DEFICIENCIES IN MECHANICAL

CHASES THROUGHOUT THE BUILDING AS THEY RELAY TO THROUGH PENETRATIONS AND OPENING

PROTECTIVES.

OPENING PROTECTIVES AND THROUGH-PENETRATIONS

THE EXISTING MECHANICAL CHASES ARE COMPARABLE TO SHAFTS AS THERE IS OPEN GRATING AT THE FLOOR LEVEL. NEW DOORS ARE REQUIRED TO HAVE A 60-MINUTE FIRE RESISTANCE RATING. EXISTING DOORS WITH A 45-MINUTE FIRE RESISTANCE RATING ARE PERMITTED TO REMAIN PER NFPA 101, PARAGRAPH 8.3.3.2.3. IN ADDITION, EXISTING STEEL DOORS WITHOUT A LABEL ARE PERMITTED TO REMAIN IF APPROVED BY THE AHJ

(NFPA 101, PARAGRAPH 8.3.3.3.4).

FIRE DAMPERS ARE REQUIRED AT ALL MECHANICAL PENETRATIONS OF THE CHASES (NFPA 90A, SECTION 5.3) EXCEPT THOSE ASSOCIATED WITH LABORATORY EXHAUST SYSTEMS. LABORATORY EXHAUST SYSTEM

PENETRATIONS MUST COMPLY WITH NFPA 45, SECTION 7.5.10.2.1.

ALL THROUGH-PENETRATIONS OF THE LABORATORY FLOOR OR MECHANICAL CHASE WALLS ARE REQUIRED TO BE PROVIDED WITH A UL-LISTED THROUGH-PENETRATION FIRESTOP SYSTEM FOR A 1-HOUR FIRE BARRIER.

INTERIOR FINISH

AS THERE ARE NO CORRIDORS WITHIN THE PROJECT AREA, INTERIOR FINISHES ARE PERMITTED TO BE CLASS A, B, OR C (NFPA 101, PARAGRAPH 40.3.3.2). THERE ARE NO REQUIREMENTS FOR INTERIOR FLOOR FINISH (NFPA

101, PARAGRAPH 40.3.3.3.2).

MEANS OF EGRESS

MEANS OF EGRESS WILL BE IN ACCORDANCE WITH NFPA 101 PER UFC 3-600-01. AS THE MAQ’S ARE NOT

EXCEEDED, THE REQUIREMENTS FOR A GENERAL INDUSTRIAL OCCUPANCY ARE APPLICABLE.

OCCUPANT LOAD (NFPA 101, TABLE 7.3.1.2)

BUSINESS: 1 PERSON PER 150 GROSS SF

LAB (INDUSTRIAL, NOT INSTRUCTIONAL): 1 PERSON PER 100 GROSS SF

STORAGE: 1 PERSON PER 500 GROSS SF

MECHANICAL/ELECTRICAL: MAXIMUM ANTICIPATED

CALCULATED OCCUPANT LOAD: 182 (GROUND FLOOR ESTIMATED)

175 (FIRST FLOOR ESTIMATED)

175 (SECOND FLOOR ESTIMATED)

NUMBER OF EXITS

A MINIMUM OF TWO EXITS ARE REQUIRED FOR ANY SPACE WITH AN OCCUPANT LOAD GREATER THAN 50

PERSONS OR AS NECESSARY TO NOT EXCEED COMMON PATH OF TRAVEL LIMITATIONS.

EXIT CAPACITY

EXITS AND EGRESS PATHS ARE TO BE SIZED FOR THE OCCUPANT LOAD SERVED. WIDTH CALCULATIONS ARE TO BE BASED ON 0.20 INCHES PER OCCUPANT FOR DOORS WITH A MINIMUM COMPONENT CLEAR WIDTH OF 32 INCHES (NFPA 101, PARAGRAPH 40.2.3). THE OCCUPANT LOAD IN THE RENOVATED AREAS ON THE FIRST AND SECOND FLOORS OF THE BUILDING SHOULD BE CONSISTENT WITH THE CURRENT OCCUPANT LOAD AS THE USE OF THE AREAS HAS NOT BEEN MODIFIED. THE OCCUPANT LOAD ON THE GROUND FLOOR WILL BE MINIMALLY

IMPACTED BY THE ADDITION OF THE MEZZANINE.

TRAVEL DISTANCE

THE MAXIMUM PERMITTED TRAVEL DISTANCE IS 250 FEET IN A FULLY SPRINKLERED BUILDING (NFPA 101, TABLE 40.2.6.1). THE LARGEST OBSERVED TRAVEL DISTANCE WITHIN THE SCOPE OF WORK IS 113 FT.

COMMON PATH OF TRAVEL

THE MAXIMUM PERMITTED COMMON PATH OF TRAVEL IS 100 FEET IN A FULLY SPRINKLERED BUILDING (NFPA 101, TABLE 40.2.5.1). THE LARGEST OBSERVED COMMON PATH OF TRAVEL WITHIN THE SCOPE OF WORK IS 86 FT.

DEAD-END CORRIDOR

THERE ARE NO CORRIDORS WITHIN THE PROJECT SCOPE OF WORK.

EMERGENCY LIGHTING

LABORATORY WORK AREAS WILL BE PROVIDED WITH EMERGENCY LIGHTING VIA BATTERY BACKUP PER NFPA 45, PARAGRAPH 5.5.3.1. EMERGENCY LIGHTING WILL BE PROVIDED FOR A MINIMUM OF 1½ HOURS IN THE EVENT OF

INTERNAL POWER FAILURE. EMERGENCY LIGHTING WILL BE IN ACCORDANCE WITH NFPA 101.

EXIT MARKING

EXIT SIGNS SHALL BE LED TYPE WITH BATTERY BACKUP AND SHALL BE PROVIDED AT ALL MEANS OF EGRESS WHERE EITHER TWO MEANS OF EGRESS ARE REQUIRED FROM A SPACE OR WHERE OCCUPANTS PASS THROUGH AN INTERVENING SPACE AND THE LOCATION OF THE EXIT IS NOT READILY APPARENT. EXIT SIGN ILLUMINATION WILL BE PROVIDED FOR A MINIMUM OF 1½ HOURS IN THE EVENT OF INTERNAL POWER FAILURE. ALL MARKING OF EXITS WILL BE IN ACCORDANCE WITH NFPA 101. EXIT SIGNS WILL BE PROVIDED WITH RED LETTERING.

WATER SUPPLY

THE EXISTING SPRINKLER SYSTEM AND FIRE HYDRANTS ARE FED FROM A LOOPED 8-INCH MAIN CONNECTED TO THE BASE WATER DISTRIBUTION SYSTEM. A WATER FLOW TEST WAS PERFORMED BY AMERICAN WATER ON JULY 27, 2021 AT 9:20 AM AND RESULTED IN A STATIC PRESSURE OF 91 POUNDS PER SQUARE INCH AND A RESIDUAL PRESSURE OF 89 POUNDS PER SQUARE INCH WHILE FLOWING 475 GALLONS PER MINUTE. A SINGLE 2 ½-INCH HOSE CONNECTION WAS UTILIZED BUT THE FLOW WAS VERY LOW IN COMPARISON TO THE MAIN SIZE AND THE OBSERVED PRESSURE. IT IS RECOMMENDED THAT THE WATER DISTRIBUTION SYSTEM IN THE AREA BE STUDIED TO VERIFY THAT NO VALVES ARE CLOSED AND THAT THERE IS NOT AN ISSUE WITH THE FIRE HYDRANT OR THE DEAD-END FEED TO THE FIRE HYDRANT. THERE ARE ADDITIONAL FIRE HYDRANTS IN THE AREA AND THE PRESSURES OBSERVED, ALONG WITH THE MAIN SIZE AND CONFIGURATION, DO NOT INDICATE THAT THERE IS AN

ISSUE SUPPORTING THE EXISTING SPRINKLER SYSTEM OR FIRE FLOW.

D (MINIMAL

FIRE HAZARD )

I

I, II, AND IIIA 1 GALLONS

1 GALLONS

75 GALLONS

75 GALLONS

2 GALLONS

2 GALLONS

150 GALLONS

150 GALLONS

FLAMMABLE

AND

COMBUSTIBLE

LIQUID CLASS

CLASS I

GROUND FLOOR

QUANTITY

FIRST FLOOR

QUANTITY

GALLONS

USE

CLASS I, II, IIIA 5

GALLONS

GROUND FLOOR

QUANTITY

GALLONS

USE AND

STORAGE

GALLONS

GALLONS

USE

GALLONS

GALLONS

USE AND

STORAGE

GALLONS

GALLONS

USE

GALLONS

GALLONS

USE AND

STORAGE

GALLONS

AUTOMATIC SPRINKLER PROTECTION

THE BUILDING IS PROVIDED WITH AN EXISTING WET PIPE AUTOMATIC SPRINKLER SYSTEM.

ON THE FIRST AND SECOND FLOORS, THERE IS MINIMAL IMPACT TO THE EXISTING

SPRINKLERS ASSOCIATED WITH UPDATED CEILINGS AND THE ADDITION/REMOVAL OF

SELECT WALLS. DUE TO THE AGE OF THE EXISTING SPRINKLERS, NEW QUICK-RESPONSE

SPRINKLERS ARE TO BE PROVIDED IN ALL AREAS WITHIN THE SCOPE OF WORK, EVEN IF

THERE ARE NO PIPE CHANGES REQUIRED. THE GROUND LEVEL LAB AREA RENOVATION

WILL RESULT IN NEW SPRINKLERS BEING PROVIDED BELOW THE MEZZANINE AND

SPRINKLERS PROVIDED ABOVE AND BELOW THE MEZZANINE IN G18A.

IT IS ANTICIPATED THAT THERE WILL BE LESS THAN 20 SPRINKLERS ADDED OR MODIFIED

AS PART OF THIS PROJECT SO SHOP DRAWINGS AND CALCULATIONS WILL NOT BE

REQUIRED PER UFC 3-600-01, PARAGRAPH 9-7.5.1.2. THE DIRECT REPLACEMENT OF

SPRINKLERS WITH NEW ONES WOULD NOT CONTRIBUTE TO THE COUNT TOTAL.

FIRE ALARM AND MASS NOTIFICATION SYSTEM

THE BUILDING IS PROVIDED WITH AN EXISTING FIRE ALARM AND MASS NOTIFICATION

SYSTEM WHICH CONSISTS OF CLEAR LENS “FIRE” STROBES AND AMBER LENS “ALERT”

STROBES FOR MASS NOTIFICATION WITH COMMON SPEAKERS SHARED BY BOTH SYSTEMS.

DUE TO THE LIMITED SCOPE OF FIRE ALARM WORK IN THE PROJECT AND THE LARGE

CAMPUS OF INTERCONNECTED BUILDINGS. AMBER LENS "ALERT" STROBES WILL REMAIN

IN USE TO MAINTAIN CONSISTENCY. INITIATING DEVICES CONSIST OF SPOT-TYPE SMOKE

DETECTORS ABOVE CONTROL UNITS, SPOT-TYPE SMOKE DETECTORS ASSOCIATED WITH

ELEVATORS, SPRINKLER WATERFLOW SWITCHES, AND MANUAL PULL STATIONS. DUCT

SMOKE DETECTORS ARE PROVIDED AS A SUPERVISORY CONDITION AND FOR ASSOCIATED

UNIT SHUT DOWN AND HVAC MANUAL SHUT DOWN SWITCHES ARE SUPERVISED BY THE

FIRE ALARM SYSTEM. ALL SPRINKLER SYSTEM CONTROL VALVES ARE SUPERVISED BY THE

FIRE ALARM SYSTEM. TEXT DISPLAYS ARE PROVIDED AT BUILDING EXITS AND MASS

NOTIFICATION SYSTEM LOCAL OPERATOR CONSOLES ARE PROVIDED ON EACH FLOOR OF

THE BUILDING. THE EXISTING FIRE ALARM AND MASS NOTIFICATION SYSTEM ALSO SERVES

AS A LAB CHEMICAL SPILL NOTIFICATION SYSTEM WHICH TRANSMITS TO THE ADJACENT

BUILDINGS IF A CHEMICAL SPILL PULL STATION IS OPERATED.

THE EXISTING AMBER LENS MASS NOTIFICATION SYSTEM STROBES ARE TO REMAIN IN USE

BASED ON THE LIMITED AREAS OF THE BUILDING THAT ARE IMPACTED BY THIS PROJECT.

IT IS ANTICIPATED THAT FIRE ALARM AND MASS NOTIFICATION SYSTEM MODIFICATIONS

WILL BE LIMITED TO THE ADDITION AND RELOCATION OF A FEW NOTIFICATION APPLIANCES.

PORTABLE FIRE EXTINGUISHER

GENERAL PURPOSE PORTABLE FIRE EXTINGUISHERS WILL BE SIZED AND SPACED IN

ACCORDANCE WITH UFC 3-600-01 AND NFPA 10. AT LEAST ONE CLASS 4A:60B:C RATED DRY

CHEMICAL PORTABLE FIRE EXTINGUISHER WILL BE PROVIDED FOR EVERY 11,250 SQUARE

FEET OF FLOOR AREA AND LOCATED SUCH THAT AN OCCUPANT TRAVELS NO MORE THAN

75 FEET BEFORE REACHING A PORTABLE FIRE EXTINGUISHER IN ALL RENOVATED AREAS.

HAZARD AND FLOOR AREA HAS NOT INCREASED SO THE EXISTING FIRE EXTINGUISHERS IN

THE CORRIDORS SHOULD BE ADEQUATE BUT ADDITIONAL FIRE EXTINGUISHERS WILL BE

PROVIDED WITHIN THE LABORATORY AREAS TO MEET THE TRAVEL DISTANCE LIMITATION.

BUILDING

20652

FLOW

HYDRANT

TEST

HYDRANT

6"

8"

8"

6" 6"

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

R

EN

O

VA

TE

R

ES

EA

R C

H L

AB

F

O R

R

AP

ID

R

EA

C

TI

O

N W

PA

FB

B U

IL

D

IN

G

W R

IG

H

T

PA

TT

ER

SO

N

A

FB

, O H

IO

ZH

TV

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

BR

O

AD

W

AY

S

TR

EE

T C

IN

C

IN

N

AT

I, O H

IO

SEAL

G-002

C O

D E

SU

M

M

AR

Y

K.

P

O

TH

IE

R

H . M

EA

D

O W

S

W . H

IG

G

IN

S

-1

6-

CERTIFIED FINAL - MAR 16, 2023

NOT TO SCALEG-002

1 FLOW TEST LOCATION DIAGRAM

S U

B M

IT

T

E D

G

H

U T

Z E

L

W

2Q R

R

_P la ns -0

SITE LOGISTICS PLAN

LOBBY ENTRANCE

LOADING DOCK AREA.

CONTRACTOR CHECK IN/OUT.

SHIPPING/RECEIVING DESK

PROPOSED CONTRACTOR

PARKING AREA, NORTH SIDE

OF EXISTING CE LOT

UNDERGROUND FACILITY

UTILITY LINES

PROPOSED CONTRACTOR

LAY DOWN AREA

BUILDING 20652

PARKING SIGNAGE AT EV PARKING

OPTION PER WPAFB INSTRUCTION

31-1001, CHAPTER 7.3, "FOR

GOVERNMENT USE ONLY"

PROPOSED HAUL ROUTE

VEHICLE

INSPECTION

GATE 26A

I-675

NATIONAL

ROAD GATE

NATIONAL

ROAD

12TH

ST.

BUILDING

20652

KAUFFMAN

ROAD

A ROAD

SKEEL

AVE.

PIERCE

DR.

LOOP RD

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

IT

R

R E

V

IE

W B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R E

N O

V A

T E

R E

S E

A R

C H

L A

B F

O R

R A

P

ID

R E

A C

T

IO

N

W P

A F

B B

U

IL

D

IN

G

W R

IG

H

T P

A T

T E

R S

O N

A F

B O

H

IO

Z H

T V

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B

R O

A D

W A

Y S

T R

E E

T C

IN

C

IN

N

A T

I, O

H

IO

SEAL 12-22-22

G-003

S

IT

E N

O T

E S

A N

D L

O G

IS

T

IC

S

J P

E S

S E

L L

M A

L B

E R

S

G H

U T

Z E

L

R S

C H

M

IT

Z

-1

-2

CERTIFIED FINAL - MAR 16, 2023

O TURN-IN ALL MERCURY CONTAINING LAMPS TO 88 CEG/CEIE IN

ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01 35 43.

P TURN-IN ALL PCB CONTAINING LIGHT BALLAST TO 88 CEG/CEIE IN

ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01 35 43.

Q 30 DAYS PRIOR TO START OF WORK, THE CONTRACTOR SHALL

TAKE A REPRESENTATIVE SAMPLE OF THE HVAC SYSTEM WATER

TO DETERMINE WHETHER IT CAN BE DRAINED DIRECTLY INTO THE

SANITARY SEWER. ANALYZE THE WATER TO DETERMINE THE TOTAL

LEVEL OF EACH OF THE FOLLOWING: ARSENIC, CADMIUM,

CHROMIUM, COPPER, CYANIDE, LEAD, MERCURY, MOLYBDENUM,

NICKEL, SELENIUM, SILVER, ZINC, SULFIDE, OIL AND GREASE,

PHOSPHORUS, COD AND BOD. THE LAB PERFORMING THE

ANALYSES MUST BE CERTIFIED BY OHIO EPA TO ANALYZE FOR

THESE PARAMETERS. PROVIDE A COPY OF THE LAB'S REPORT TO

THE CONTRACTING OFFICER, WHO WILL IN TURN FORWARD IT TO 88

CEG/CEIEA FOR A DETERMINATION ON THE WASTEWATER

DISPOSAL METHOD.

R COORDINATE DISPOSITION OF EXCESS RADIOACTIVE

COMMODITIES, E.G. IONIZATION TYPE SMOKE DETECTORS,

RADIOLUMINESCENT EMERGENCY EXIT SIGNS, OR ANY OTHER

RADIOACTIVE COMMODITY AND/OR RADIOACTIVE CONTAMINANT

THROUGH THE INSTALLATION RADIATION SAFETY OFFICER, 88

OMRS/SGXB.

S PROJECT LAYDOWN AREA IS WITHIN LANDFILL BUFFER. ANY SOIL

DISTURBANCE (PENETRATING, DIGGING, SCRAPING, MOVEMENT OF

HEAVY EQUIPMENT, ETC.) IN THIS AREA REQUIRES THE

COORDINATION AND APPROVAL FROM THE OHIO ENVIRONMENTAL

PROTECTION AGENCY. ALLOW A MINIMUM OF 90 DAYS TO PROCESS

AND SUBMIT AN APPLICATION FOR AUTHORIZATION -

ENVIRONMENTAL RESTORATION SITE DISTURBANCE TO OEPA IAW

OAC 3745-513 (F). ALLOW A MINIMUM 90 DAYS TO PROCESS THE

REQUEST THROUGH AFCEC/CZOM. CONTACT MR. JOHN CROCKER,

REMEDIAL PROJECT MANAGER AT JOHN.CROCKER.5@US.AF.MIL OR

(936) 257-2312 FOR ADDITIONAL INFORMATION.

T THE CONTRACTOR SHALL SURVEY FUME HOOD SYSTEMS AND SINK

TRAPS THAT ARE TO BE REMOVED OR ALTERED DURING

RENOVATION / DEMOLITION ACTIVITIES. THE SURVEY SHALL

INCLUDE CHEMICAL TESTING WHERE APPLICABLE, TO DETERMINE

IF A POTENTIALLY SHOCK SENSITIVE OR EXPLOSIVE SITUATION

EXISTS. SURVEY SHALL ALSO INCLUDE DETERMINING THE

PRESENCE OF LIQUID MERCURY IN SINK TRAPS, TRAPS UNDER

FLOOR DRAINS, AND IN CONCRETE SEAMS/CRACKS. ANALYTICAL

RESULTS AND SURVEY REPORT SHALL BE SUBMITTED TO 88

CEG/CEIEA, MARIA CRUSET HAZARDOUS WASTE PM,

MARIA.CRUSET@US.AF.MIL OR 937-257-0023.

A ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH WPAFB

SPECIFICATION SECTION 01 35 43 GENERAL ENVIRONMENTAL

REQUIREMENTS (WPAFB).

B NO ASBESTOS-CONTAINING MATERIAL SHALL BE INSTALLED

DURING THIS PROJECT.

C SOIL DISTURBANCE DURING THIS PROJECT, INCLUDING EQUIPMENT

STAGING AREAS, WILL REQUIRE EROSION CONTROL MEASURES.

FOR PROJECTS THAT DISTURB LESS THAN AN ACRE OF SOIL, AN

EROSION CONTROL PLAN IS REQUIRED PRIOR TO SOIL

DISTURBANCE. FOR PROJECTS THAT DISTURB MORE THAN AN

ACRE, A NOTICE OF INTENT (NOI) MUST BE APPROVED BY THE OHIO

EPA PRIOR TO ANY SOIL BEING DISTURBED AS WELL AS A STORM

WATER POLLUTION PREVENTION PLAN (SWPPP) APPROVED BY 88

CEG/CEIEA. PLEASE CONTACT THE 88 CEG/CEIEA WATER PM MIKE

VAUGHN, (937-257-8028 OR MICHAEL.VAUGHN.3@US.AF.MIL) FOR

ADDITIONAL INFORMATION.

D THE GENERATION OF FUGITIVE EMISSIONS MUST BE KEPT TO A

MINIMUM USING APPROVED DUST SUPPRESSING METHODS SUCH

AS WATER SPRAYS ON AREA OF HIGH DUST GENERATION. FOR

ADDITIONAL INFORMATION PLEASE CONTACT THE 88 CEG/CEIEA AIR

PM CHET POWERS AT 937-257-3349 OR BY EMAIL AT

CHET.POWERS@US.AF.MIL.

E REMOVE AND DISPOSE OF ANY ASBESTOS CONTAINING MATERIAL

IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01 35 43.

F ALL WINDOW AND DOOR FRAME CAULKING AND GLAZING WILL BE

TREATED AS CONTAINING ASBESTOS UNLESS TESTING PROVES IT

TO BE ASBESTOS FREE.

G DEMOLITION OF LOAD-BEARING WALLS OR STRUCTURAL

COMPONENTS REQUIRE NOTIFICATION OF DEMOLITION AND

RENOVATION TO THE REGIONAL AIR POLLUTION AND CONTROL

AGENCY (RAPCA) A MINIMUM OF 10 WORK DAYS PRIOR TO

BEGINNING CONSTRUCTION.

H RECOVER AND RECLAIM ANY REFRIGERANT IN ACCORDANCE WITH

WPAFB SPECIFICATION SECTION 01 35 43 GENERAL

ENVIRONMENTAL REQUIREMENTS (WPAFB).

I IF ANY REFRIGERANT-CONTAINING EQUIPMENT SCHEDULED FOR

NEW INSTALLATION, INCLUDING WATER COOLERS, THEY MUST

UTILIZE AN HFC REFRIGERANT. CFC AND HCFC REFRIGERANTS ARE

NOT AUTHORIZED FOR NEW EQUIPMENT INSTALLATION. FOR

ADDITIONAL INFORMATION PLEASE CONTACT THE 88 CEG/CEIEA AIR

PROGRAM MR. CHET POWERS AT 937-257-3349 OR

CHET.POWERS@US.AF.MIL.

J SUBMIT A REFRIGERANT RECORD WITHIN ONE DAY OF COMPLETION

OF WORK INVOLVING REFRIGERANTS TO THE 88 CEG/CEIEA AIR

PROGRAM, CHET POWERS AT 937-257-3349 OR

CHET.POWERS@US.AF.MIL.

K ALL HAZARDOUS MATERIALS MUST BE PROPERLY MANAGED,

LABELED AND STORED. ANY HAZARDOUS WASTE GENERATED

FROM THIS CONSTRUCTION ACTIVITY MUST BE PROPERLY

CHARACTERIZED, LABELED AND MANAGED BY TRAINED EMPLOYEE

OF THE CONTRACTOR WITH KNOWLEDGE OF THE ACTIVITY /

PROCESS WHERE THE WASTE WAS GENERATED. ALL HAZARDOUS

WASTE WILL BE TURNED OVER TO THE GOV'T FOR DISPOSAL. IN

ADDITION, PROPER COORDINATION IS NEEDED WITH 88 CEG/CEIEC.

QUESTIONS CONCERNING THE REQUIREMENTS FOR STORAGE AND

DISPOSAL OF ANY HAZARDOUS MATERIALS CAN BE ADDRESSED BY

THE 88 CEG/CEIEC HAZARDOUS MATERIALS PM AT

KAREN.BEASON@US.AF.MIL OR 937-257-5899 OR 88 CEG/CEIEC

HAZARDOUS WASTE PM, MARIA.CRUSET@US.AF.MIL OR

937-257-0023.

L LEAD BASED PAINT WASTE GENERATED FROM ABATEMENT

ACTIVITIES SHALL BE MANAGED AND DISPOSED AS HARDOUS

WASTE IN ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01

35 43.

M ALL METAL AND WIRING SHALL BE RECYCLED AT THE WPAFB BASE

RECYCLING CENTER. THE WPAFB RECYCLING CENTER IS

AVAILABLE FOR CONTRACTOR USE TO REDUCE WASTE DISPOSAL.

ALL RECYCLABLE METAL IS TO BE RECYCLED THROUGH THE BASE

RECYCLING CENTER. ALL RECYCLING MUST BE ACCOMPLISHED IN

ACCORDANCE WITH WPAFB SPECIFICATION SECTION 01 35 43.

CONTACT WPAFB RECYCLING PROGRAM MANAGER AT 937-257-5060

TO CONFIRM WHAT MATERIALS ARE RECYCLABLE AND TO

COORDINATE TURN-IN. THE CONTRACTOR SHALL SUBMIT A

QUARTERLY SUMMARY REPORT TO THE GOVERNMENT CONTRACT

REPRESENTATIVE IAW WPAFB SPECIFICATION SECTION 01 35 43

STATING (1) THE COST TO RECYCLE AND THE TONNAGE OF

CONSTRUCTION AND DEMOLITION MATERIALS RECYCLED, (2) THE

COST TO DIVERT/REUSE THE TONNAGE OF CONSTRUCTION AND

DEMOLITION MATERIALS DIVERTED/REUSE, (3) THE COST TO MULCH

AND THE TONNAGE AND COST OF CONSTRUCTION AND DEMOLITION

MATERIALS MULCHED, (4) THE COST FOR WASTE-TO-ENERGY AND

THE TONNAGE OF CONSTRUCTION AND DEMOLITION MATERIALS

CONVERTED FROM WASTE-TO-ENERGY, (5) THE COST TO LANDFILL

AND THE TONNAGE OF CONSTRUCTION AND DEMOLITION

MATERIALS LAND-FILLED, (6) THE COST TO INCINERATE AND THE

TONNAGE OF CONSTRUCTION AND DEMOLITION MATERIALS

INCINERATED, AND (7) EXPLANATION OF THE DIVERSION RATE IF

LESS THAN 60%. THE QUARTERLY SUMMARY REPORTS SHALL BE

RECEIVED ON APRIL 7, JULY 7, OCTOBER 7, AND JANUARY 7

COVERING THE THREE MONTHS PRIOR. THE QUARTERLY SUMMARY

REPORTS SHALL BE ON THE WPAFB DIVERSION FORM. FOR

ADDITIONAL INFORMATION CONTACT THE RECYCLING PM, BRIAN

ROBINSON, AT 937-257-5060 OR BRIAN.ROBINSON.5@US.AF.MIL.

N TURN-IN ALL MERCURY CONTAINING DEVICES, SWITCHES AND

THERMOSTATS TO 88 CEG/CEIE IN ACCORDANCE WITH WPAFB

SPECIFICATION SECTION 01 35 43 FOR RECYCLING.

N

N

GENERAL NOTES WPAFB ENVIRONMENTAL

W

2Q R

R

_P la ns -0

7 8 9 10

J

G

Fb

8.77.3

F.9

F.1

F.3

7.8 8.5

G.2

G.4

8.8 9.4

G18A

G18

EV CHARGING STATION,

REFER TO ELECTRICAL

DRAWINGS

7 8 9 10

G

Fb

G18M

BID LEGEND

OPTION 1

OPTION 2

OPTION 3

OPTION 4

BASE BID

OPTION 5

6 7 8 9 10 11 12 13 14 15

L

J

G

39 40

40B

30A

40C

UTILITY

SHAFT 1

UTILITY

SHAFT 2

UTILITY

SHAFT 3

UTILITY

SHAFT 4

KEY PLAN

KEY PLAN

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

IT

R

R E

V

IE

W B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R E

N O

V A

T E

R E

S E

A R

C H

L A

B F

O R

R A

P

ID

R E

A C

T

IO

N

W P

A F

B B

U

IL

D

IN

G

W R

IG

H

T P

A T

T E

R S

O N

A F

B O

H

IO

Z H

T V

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B

R O

A D

W A

Y S

T R

E E

T

C

IN

C

IN

N A

T I, O

H

IO

SEAL 12-22-22

G-004

B A

S E

B

ID

A N

D B

ID

O

P T

IO

N

S

J P

E S

S E

L L

M A

L B

E R

S

G H

U T

Z E

L

R S

C H

M

IT

Z

-1

-2

CERTIFIED FINAL - MAR 16, 2023

1/8" = 1'-0"G-004

01 GROUND FLOOR PLAN

1/8" = 1'-0"G-004

02 GROUND FLOOR MEZZANINE PLAN

1/8" = 1'-0"G-004

03 FIRST FLOOR PLAN

W

2Q R

R

_P la ns -0

6 7 8 9 10 11 12 13 14 15

L

J

G

UTILITY

SHAFT 1

UTILITY

SHAFT 2

UTILITY

SHAFT 3

UTILITY

SHAFT 4

BID LEGEND

OPTION 1

OPTION 2

OPTION 3

OPTION 4

BASE BID

OPTION 5

KEY PLAN

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

IT

R

R E

V

IE

W B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R E

N O

V A

T E

R E

S E

A R

C H

L A

B F

O R

R A

P

ID

R E

A C

T

IO

N

W P

A F

B B

U

IL

D

IN

G

W R

IG

H

T P

A T

T E

R S

O N

A F

B O

H

IO

Z H

T V

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B

R O

A D

W A

Y S

T R

E E

T

C

IN

C

IN

N A

T I, O

H

IO

SEAL 12-22-22

G-005

B A

S E

B

ID

A N

D B

ID

O

P T

IO

N

S

J P

E S

S E

L L

M A

L B

E R

S

G H

U T

Z E

L

R S

C H

M

IT

Z

-1

-2

CERTIFIED FINAL - MAR 16, 2023

1/8" = 1'-0"G-005

01 SECOND FLOOR PLAN

W

2Q R

R

_P la ns -0

7 8 9 10

L

J

G

Fb

8.77.3

F.9

F.1

G18A

G18

PH1-01 PH1-02

F.3

7.8 8.5

G.2

G.4

8.8 9.4

AUTOCLAVE

TO REMAIN

PHASING LEGEND

ACTIVE DEMOLITION OR

CONSTRUCTION SCOPE

TEMPORARY DUST-PROOF PARTITION

EXISTING FUME HOOD

TO BE RELOCATED

NEW FUME HOOD

EXISTING FUME HOOD

TO REMAIN

P H

A S

E

ROOM END USER

G18

G18A

STRUCTURAL MATERIALS EVALUATION LAB

STRUCTURAL MATERIALS EVALUATION LAB

30A

40B

NON-DESTRUCTIVE INSPECTION LAB

ALL

STRUCTURAL FAILURE LAB

STRUCTURAL FAILURE LAB

STRUCTURAL FAILURE LAB

NON-DESTRUCTIVE INSPECTION LAB

NON-DESTRUCTIVE INSPECTION LAB

117 STRUCTURAL MATERIALS EVALUATION LAB

G18M STRUCTURAL MATERIALS EVALUATION LAB

19 STRUCTURAL FAILURE LAB

20 ELECTRICAL FAILURE LAB

28 STRUCTURAL FAILURE LAB

38 NON-DESTRUCTIVE INSPECTION LAB

39 NON-DESTRUCTIVE INSPECTION LAB

40 NON-DESTRUCTIVE INSPECTION LAB

145 STRUCTURAL MATERIALS EVALUATION LAB

P H

A S

E

NEW CAPTURE HOOD

40 NON-DESTRUCTIVE INSPECTION LAB

7 8 9 10

L

J

G

Fb

8.77.3

F.9

F.1

G18A

G18

PH1-03 PH1-04 PH1-05

ON MEZZANINE

ON MEZZANINE

F.3

7.8 8.5

G.2

G.4

8.8 9.4

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

IT

R

R E

V

IE

W B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R E

N O

V A

T E

R E

S E

A R

C H

L A

B F

O R

R A

P

ID

R E

A C

T

IO

N

W P

A F

B B

U

IL

D

IN

G

W R

IG

H

T P

A T

T E

R S

O N

A F

B O

H

IO

Z H

T V

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B

R O

A D

W A

Y S

T R

E E

T

C

IN

C

IN

N A

T I, O

H

IO

KEY PLAN

SEAL 12-22-22

G-011

G R

O U

N D

F L O

O R

P H

A S

IN

G

P L A

N

P H

A S

E

J P

E S

S E

L L

M A

L B

E R

S

G H

U T

Z E

L

R S

C H

M

IT

Z

-1

-2

CERTIFIED FINAL - MAR 16, 2023

1/8" = 1'-0"G-011

01 GROUND FLOOR PHASE 1 PLAN

N 16'4' 8'

SCALE: 1/8"=1'-0"

PHASING NOTES

STRUCTURAL MATERIALS EVALUATION LAB STRUCTURAL MATERIALS EVALUATION LAB

1/8" = 1'-0"G-011

02 MEZZANINE PHASE 1 PLAN

NOTE: AUTOCLAVE PROTECTION TO BE A 3 5/8" METAL STUD ENCLOSURE AT 24" ON CENTER WITH 6 MIL PLASTIC

SHEET. PROVIDE A 3'-0" WIDE X 7'-0" HIGH ACCESS FLAP WITH HOOK AND LOOP CLOSURE STRIPS FOR DEPARTMENT

PERSONNEL ACCESS TO AUTOCLAVE. PROVIDE 3'-0" MINIMUM CLEARANCE INSIDE. PROVIDE TEMPORARY LIGHTING.

COORDINATE DEPARTMENT-PROVIDED TEMPORARY CAPTURE HOOD PLACEMENT WITH DEPARTMENT PERSONNEL.

PH1-01 LAB EQUIPMENT TO BE MOVED TO TEMPORARY LOCATION BY DEPARTMENT PERSONNEL PRIOR TO

CONSTRUCTION COMMENCING. AUTOCLAVE TO REMAIN IN PLACE AND PROTECTED DURING

CONSTRUCTION. CONSTRUCTION CONTRACTOR TO ALLOW THE AUTOCLAVE TO BE OPERATED

WHILE CONSTRUCTION WORK IS ON-GOING. DEPARTMENT TO GIVE CONTRACTOR A MINIMUM OF 72

WORKING HOURS PRIOR NOTICE. DETAILS TO BE WORKED OUT WITH THE CONTRACTOR AND

GOVERNMENT DURING THE PROJECT START UP PHASE

PH1-02 DEMOLITION AND UTILITY WORK COMMENCES. REFER TO MEP AND LIFE SAFETY DRAWINGS FOR

ADDITIONAL INFORMATION

PH1-03 NEW WORK COMMENCES. INSTALL MEZZANINES AND RELOCATE UTILITIES, REFER TO MEP AND LIFE

SAFETY DRAWINGS FOR ADDITIONAL INFORMATION

PH1-04 INSTALL FINISHES AND LAB CASEWORK

PH1-05 DEPARTMENT PERSONNEL TO RE-INSTALL LAB EQUIPMENT STORED IN TEMPORARY LOCATIONS

AFTER CONSTRUCTION WORK HAS BEEN FINISHED AND ACCEPTED

W

2Q R

R

_P la ns -0

N

7 8 11 12 13 14 15

L

J

G

40B

30A

30 3129

PH1-06

PH1-07

PH1-08

PH1-09 PH1-11

PH1-13

PH1-08PH1-10

PH1-11

PH1-11

PH1-11

PH1-11

PH1-11

PH1-11

PH1-11

PH1-12

PH1-14

40C

PH1-15

PH1-15

PH1-15 PH1-15 PH1-15

PH1-15

PH1-15

PH1-12

UTILITY

SHAFT 1

UTILITY

SHAFT 3

UTILITY

SHAFT 4

PHASING LEGEND

ACTIVE DEMOLITION OR

CONSTRUCTION SCOPE

TEMPORARY DUST-PROOF PARTITION

EXISTING FUME HOOD

TO BE RELOCATED

NEW FUME HOOD

EXISTING FUME HOOD

TO REMAIN

P H

A S

E

ROOM END USER

G18

G18A

STRUCTURAL MATERIALS EVALUATION LAB

STRUCTURAL MATERIALS EVALUATION LAB

30A

40B

NON-DESTRUCTIVE INSPECTION LAB

ALL

STRUCTURAL FAILURE LAB

STRUCTURAL FAILURE LAB

STRUCTURAL FAILURE LAB

NON-DESTRUCTIVE INSPECTION LAB

NON-DESTRUCTIVE INSPECTION LAB

117 STRUCTURAL MATERIALS EVALUATION LAB

G18M STRUCTURAL MATERIALS EVALUATION LAB

19 STRUCTURAL FAILURE LAB

20 ELECTRICAL FAILURE LAB

28 STRUCTURAL FAILURE LAB

38 NON-DESTRUCTIVE INSPECTION LAB

39 NON-DESTRUCTIVE INSPECTION LAB

40 NON-DESTRUCTIVE INSPECTION LAB

145 STRUCTURAL MATERIALS EVALUATION LAB

P H

A S

E

NEW CAPTURE HOOD

40 NON-DESTRUCTIVE INSPECTION LAB

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

IT

R

R E

V

IE

W B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R E

N O

V A

T E

R E

S E

A R

C H

L A

B F

O R

R A

P

ID

R E

A C

T

IO

N

W P

A F

B B

U

IL

D

IN

G

W R

IG

H

T P

A T

T E

R S

O N

A F

B O

H

IO

Z H

T V

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B

R O

A D

W A

Y S

T R

E E

T

C

IN

C

IN

N A

T I, O

H

IO

KEY PLAN

SEAL 12-22-22

G-012

F

IR

S T

F L O

O R

P H

A S

IN

G

P L A

N

P H

A S

E

J P

E S

S E

L L

M A

L B

E R

S

G H

U T

Z E

L

R S

C H

M

IT

Z

-1

-2

CERTIFIED FINAL - MAR 16, 2023

1/8" = 1'-0"G-012

01 FIRST FLOOR PHASE 1 PLAN NON-DESTRUCTIVE INSPECTION LAB, STRUCTURAL FAILURE LAB, AND ELECTRICAL FAILURE LAB

N 16'4' 8'

SCALE: 1/8"=1'-0"

PHASING NOTES

PH1-06 LAB EQUIPMENT TO BE MOVED FROM LAB 30A TO TEMPORARY LOCATIONS OR LAB 28 BY DEPARTMENT PERSONNEL PRIOR TO

CONSTRUCTION COMMENCING. LOOSE EQUIPMENT AND CHEMICALS TO BE REMOVED IN ROOM 40C PRIOR TO CONSTRUCTION

COMMENCING

PH1-07 DEPARTMENT PERSONNEL TO MOVE ALL LAB EQUIPMENT FROM 27 TO STAGING AREA OF 38 AND TEMPORARY LOCATIONS PRIOR TO

CONSTRUCTION COMMENCING

PH1-08 DEPARTMENT PERSONNEL TO MOVE ALL LAB EQUIPMENT IN 49 TO THE STAGING AREA OF 40 AND ALL LAB EQUIPMENT IN 31 TO

EXISTING 20 AND TEMPORARY LOCATIONS PRIOR TO CONSTRUCTION COMMENCING

PH1-09 DEPARTMENT PERSONNEL TO MOVE ALL LAB EQUIPMENT IN 19 TO TEMPORARY LOCATIONS PRIOR TO CONSTRUCTION COMMENCING

PH1-10 LAB EQUIPMENT TO BE MOVED FROM LAB 30 TO TEMPORARY LOCATIONS BY DEPARTMENT PERSONNEL PRIOR TO CONSTRUCTION

COMMENCING

PH1-11 AT THE BEGINNING OF THE PHASE, TEMPORARILY CAP DUCTWORK AND PIPING AND BALANCE SYSTEM FOR LOWER CFM. AFTER

CONSTRUCTION ON THIS PHASE IS COMPLETE, RECONNECT DUCTWORK AND PIPING AND REBALANCE SYSTEM FOR ORIGINAL CFM

AND GPM. PROTECT EXISTING GEORATOR TO REMAIN IN ROOM 19

PH1-12 CONSTRUCT TEMPORARY DUST PARTITION IN 40 IN LOCATIONS INDICATED

PH1-13 CONSTRUCT TEMPORARY DUST PARTITION BETWEEN 27 AND 38 AS SHOWN. NOTIFY DEPARTMENT A MINIMUM OF 72 HOURS PRIOR TO

CONSTRUCTION TO ALLOW FOR DISCONNECTION AND MOVING OF SMALL UT TANK BY DEPARTMENT PERSONNEL

PH1-14 REMOVE CMU WALL WALL BETWEEN 30A AND 40C

PH1-15 COMMENCE RENOVATION OF ROOMS 19, 27, 30, 30A, 31, 40B, 40C, AND 49

W

2Q R

R

_P la ns -0

PHASING LEGEND

ACTIVE DEMOLITION OR

CONSTRUCTION SCOPE

TEMPORARY DUST-PROOF PARTITION

EXISTING FUME HOOD

TO BE RELOCATED

NEW FUME HOOD

EXISTING FUME HOOD

TO REMAIN

P H

A S

E

ROOM END USER

G18

G18A

STRUCTURAL MATERIALS EVALUATION LAB

STRUCTURAL MATERIALS EVALUATION LAB

30A

40B

NON-DESTRUCTIVE INSPECTION LAB

ALL

STRUCTURAL FAILURE LAB

STRUCTURAL FAILURE LAB

STRUCTURAL FAILURE LAB

NON-DESTRUCTIVE INSPECTION LAB

NON-DESTRUCTIVE INSPECTION LAB

117 STRUCTURAL MATERIALS EVALUATION LAB

G18M STRUCTURAL MATERIALS EVALUATION LAB

19 STRUCTURAL FAILURE LAB

20 ELECTRICAL FAILURE LAB

28 STRUCTURAL FAILURE LAB

38 NON-DESTRUCTIVE INSPECTION LAB

39 NON-DESTRUCTIVE INSPECTION LAB

40 NON-DESTRUCTIVE INSPECTION LAB

145 STRUCTURAL MATERIALS EVALUATION LAB

P H

A S

E

NEW CAPTURE HOOD

40 NON-DESTRUCTIVE INSPECTION LAB

8 9 10 11

L

J

G

PH1A-21

PH1A-23

PH1A-24

PH1A-25

PH1A-26

PH1A-22

UTILITY

SHAFT 2

8 9 10

L

J

G

PH1-21

PH1-22

PH1-23

PH1-24

PH1-25

PH1-26

UTILITY

SHAFT 2

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

IT

R

R E

V

IE

W B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R E

N O

V A

T E

R E

S E

A R

C H

L A

B F

O R

R A

P

ID

R E

A C

T

IO

N

W P

A F

B B

U

IL

D

IN

G

W R

IG

H

T P

A T

T E

R S

O N

A F

B O

H

IO

Z H

T V

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B

R O

A D

W A

Y S

T R

E E

T

C

IN

C

IN

N A

T I, O

H

IO

KEY PLAN

SEAL 12-22-22

G-013

S E

C O

N D

F L O

O R

P H

A S

IN

G

P L A

N

P H

A S

E

J P

E S

S E

L L

M A

L B

E R

S

G H

U T

Z E

L

R S

C H

M

IT

Z

-1

-2

CERTIFIED FINAL - MAR 16, 2023

N 16'4' 8'

SCALE: 1/8"=1'-0"

PHASING NOTES

1/8" = 1'-0"G-013

02 SECOND FLOOR PHASE 1A PLAN

STRUCTURAL MATERIALS EVALUATION LAB STRUCTURAL MATERIALS EVALUATION LAB

1/8" = 1'-0"G-013

01 SECOND FLOOR PHASE 1 PLAN

PHASING NOTES

PH1-21 LAB EQUIPMENT TO BE MOVED FROM LAB 117 TO

TEMPORARY LOCATIONS OR LAB 145 BY DEPARTMENT

PERSONNEL PRIOR TO CONSTRUCTION COMMENCING

PH1-22 INSTALL TEMPORARY PARTITION IN LOCATION INDICATED.

LAB 145 IS TO BE DUST-FREE DURING THE

CONSTRUCTION OF LAB 117

PH1-23 TEMPORARILY CAP DUCTWORK AND PIPING AND

BALANCE SYSTEM FOR LOWER CFM. AFTER

CONSTRUCTION ON THIS PHASE IS COMPLETE,

RECONNECT DUCTWORK AND PIPING AND REBALANCE

SYSTEM FOR ORIGINAL CFM AND GPM.

PH1-24 DEMOLITION AND UTILITY WORK COMMENCES. REFER TO

MEP AND LIFE SAFETY DRAWINGS FOR ADDITIONAL

INFORMATION

PH1-25 NEW WORK COMMENCES

PH1-26 AFTER NEW CONSTRUCTION IS COMPLETED AND

ACCEPTED, LAB EQUIPMENT WILL BE MOVED BACK INTO

LAB 117 BY DEPARTMENT PERSONNEL

PH1A-21 DESIGNATED LAB EQUIPMENT TO BE MOVED FROM LAB 145

TO TEMPORARY LOCATIONS OR LAB 117 BY DEPARTMENT

PERSONNEL

PH1A-22 RETAIN TEMPORARY PARTITION IN LOCATION INDICATED. LAB

117 IS TO BE DUST-FREE DURING THE CONSTRUCTION OF LAB

PH1A-23 TEMPORARILY CAP DUCTWORK AND PIPING AND BALANCE

SYSTEM FOR LOWER CFM. AFTER CONSTRUCTION ON THIS

PHASE IS COMPLETE, RECONNECT DUCTWORK AND PIPING

AND REBALANCE SYSTEM FOR ORIGINAL CFM AND GPM.

PH1A-24 AFTER DEPARTMENT PERSONNEL HAS RELOCATED ALL LAB

EQUIPMENT, DEMOLITION AND UTILITY WORK COMMENCES.

REFER TO MEP AND LIFE SAFETY DRAWINGS FOR ADDITIONAL

INFORMATION

PH1A-25 NEW WORK COMMENCES

PH1A-26 AFTER NEW CONSTRUCTION IS COMPLETED AND ACCEPTED,

LAB EQUIPMENT WILL BE MOVED BACK INTO LAB 145 BY

DEPARTMENT PERSONNEL

NOTE: LAB 117 SHALL BE COMPLETED AND ACCEPTED BY THE GOVERNMENT

PRIOR TO STARTING CONSTRUCTION ON LAB 145

W

2Q R

R

_P la ns -0

CONSTRUCTION SCOPE

TEMPORARY DUST-PROOF PARTITION

EXISTING FUME HOOD

TO BE RELOCATED

NEW FUME HOOD

EXISTING FUME HOOD

TO REMAIN

P H

A S

E

ROOM END USER

G18

G18A

STRUCTURAL MATERIALS EVALUATION LAB

STRUCTURAL MATERIALS EVALUATION LAB

30A

40B

NON-DESTRUCTIVE INSPECTION LAB

ALL

STRUCTURAL FAILURE LAB

STRUCTURAL FAILURE LAB

STRUCTURAL FAILURE LAB

NON-DESTRUCTIVE INSPECTION LAB

NON-DESTRUCTIVE INSPECTION LAB

117 STRUCTURAL MATERIALS EVALUATION LAB

G18M STRUCTURAL MATERIALS EVALUATION LAB

19 STRUCTURAL FAILURE LAB

20 ELECTRICAL FAILURE LAB

28 STRUCTURAL FAILURE LAB

38 NON-DESTRUCTIVE INSPECTION LAB

39 NON-DESTRUCTIVE INSPECTION LAB

40 NON-DESTRUCTIVE INSPECTION LAB

145 STRUCTURAL MATERIALS EVALUATION LAB

P H

A S

E

NEW CAPTURE HOOD

40 NON-DESTRUCTIVE INSPECTION LAB

N

7 8 11 12 13 14 15

L

J

G

40 40B

30A

PH2-02

PH2-03

PH2-04

PH2-08

PH2-06

PH2-09

PH2-11

PH2-07

PH2-13

PH2-05

PH2-01

PH2-01PH2-14

NEW WALL

BETWEEN LABS

39 AND 40 IS

PART OF THE

BASE BID

PH2-12

PH2-10

PH2-15

UTILITY

SHAFT 1

UTILITY

SHAFT 3

UTILITY

SHAFT 4

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

IT

R

R E

V

IE

W B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R E

N O

V A

T E

R E

S E

A R

C H

L A

B F

O R

R A

P

ID

R E

A C

T

IO

N

W P

A F

B B

U

IL

D

IN

G

W R

IG

H

T P

A T

T E

R S

O N

A F

B O

H

IO

Z H

T V

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B

R O

A D

W A

Y S

T R

E E

T

C

IN

C

IN

N A

T I, O

H

IO

KEY PLAN

SEAL 12-22-22

G-021

F

IR

S T

F L O

O R

P H

A S

IN

G

P L A

N

P H

A S

E

J P

E S

S E

L L

M A

L B

E R

S

G H

U T

Z E

L

R S

C H

M

IT

Z

-1

-2

CERTIFIED FINAL - MAR 16, 2023

NON-DESTRUCTIVE INSPECTION LAB, STRUCTURAL FAILURE LAB, AND ELECTRICAL FAILURE LAB

N 16'4' 8'

SCALE: 1/8"=1'-0"

1/8" = 1'-0"G-021

01 FIRST FLOOR PHASE 2 PLAN

PHASING NOTES

PH2-01 RETAIN TEMPORARY PARTITION IN LOCATION INDICATED

PH2-02 AFTER NEW CONSTRUCTION IS COMPLETED AND ACCEPTED IN LABS 27 AND 49, DEPARTMENT PERSONNEL TO MOVE DESIGNATED LAB

EQUIPMENT IN 38 TO RENOVATED 27, 49 AND TEMPORARY LOCATIONS

PH2-03 AFTER NEW CONSTRUCTION IS COMPLETED AND ACCEPTED IN LAB 49, DEPARTMENT PERSONNEL TO MOVE THERMAL ANALYSIS

EQUIPMENT FROM 38 TO RENOVATED 49

PH2-04 AFTER NEW CONSTRUCTION IS COMPLETED AND ACCEPTED IN LAB 19, DEPARTMENT PERSONNEL TO MOVE MACHINE SHOP CAPABILITY

IN 20 TO RENOVATED 19. TEMPORARILY CAP DUCTWORK AND PIPING AND BALANCE SYSTEM FOR LOWER CFM. AFTER CONSTRUCTION

ON THIS PHASE IS COMPLETE, RECONNECT DUCTWORK AND PIPING AND REBALANCE SYSTEM FOR ORIGINAL CFM AND GPM

PH2-05 AFTER DEPARTMENT PERSONNEL HAS RELOCATED ALL LAB EQUIPMENT, COMMENCE RENOVATION OF LAB 20 MEP, FINISHES AND LIFE

SAFETY

PH2-06 TEMPORARILY CAP DUCTWORK AND PIPING AND BALANCE SYSTEM FOR LOWER CFM. AFTER CONSTRUCTION ON THIS PHASE IS

COMPLETE, RECONNECT DUCTWORK AND PIPING AND REBALANCE SYSTEM FOR ORIGINAL CFM AND GPM

PH2-07 AFTER DEPARTMENT PERSONNEL HAS RELOCATED ALL LAB EQUIPMENT, COMMENCE RENOVATION OF LAB 38 MEP, FINISHES AND LIFE

SAFETY, INCLUDING LARGE UT TANK PROTECTION

PH2-08 INSTALL TEMPORARY PARTITION TO ALLOW FOR CONTINUED OPERATION OF EXISTING FPI LINE. COMMENCE HVAC RENOVATION AND

UTILITY WORK AT NEW FPI LINE LOCATION IN THE NORTH SIDE OF LAB 39

PH2-09 AFTER NEW CONSTRUCTION IS COMPLETED AND ACCEPTED IN LAB 30A, DEPARTMENT PERSONNEL TO MOVE DESIGNATED LAB

EQUIPMENT IN 28 TO RENOVATED 30A

PH2-10 REMOVAL OF EXISTING ACCORDION DOOR AND INSTALLATION OF NEW GYPSUM BOARD PARTITION AND DOORS ARE PART OF THE BASE

BID, BUT EXECUTED IN PHASE 2B

PH2-11 AFTER DEPARTMENT PERSONNEL HAS RELOCATED ALL LAB EQUIPMENT, COMMENCE RENOVATION OF LAB 28 AND ROOM 29 MEP, FINISHES AND LIFE SAFETY

PH2-12 AFTER NEW CONSTRUCTION IS COMPLETED AND ACCEPTED IN THE NORTH SIDE OF LAB 39, CONTRACTOR TO DISCONNECT EXISTING FPI

LINE AND RECONNECT IN NEW LOCATION. FPI LINE TO BE UNAVAILABLE TO DEPARTMENT PERSONNEL FOR A MXIMUM OF TWO WEEKS

PH2-13 AFTER NEW CONSTRUCTION IS COMPLETED AND ACCEPTED IN LAB 20, DEPARTMENT PERSONNEL TO MOVE DESIGNATED LAB

EQUIPMENT IN TEMPORARY LOCATIONS TO RENOVATED 20

PH2-14 AFTER NEW CONSTRUCTION IS COMPLETED AND ACCEPTED IN LAB 38, THE TEMPORARY PARTITION CAN BE REMOVED, AND

DEPARTMENT PERSONNEL TO MOVE DESIGNATED LAB EQUIPMENT IN 27 TO RENOVATED 38

PH2-15 AFTER NEW CONSTRUCTION IS COMPLETED AND ACCEPTED IN LAB 28, DEPARTMENT PERSONNEL TO MOVE DESIGNATED LAB

EQUIPMENT IN TEMPORARY LOCATIONS TO RENOVATED 28

NOTE: SEE SHEET AD102 FOR PROTECTION OF LARGE UT TANK DURING PHASE 2

W

2Q R

R

_P la ns -0

CONSTRUCTION SCOPE

TEMPORARY DUST-PROOF PARTITION

EXISTING FUME HOOD

TO BE RELOCATED

NEW FUME HOOD

EXISTING FUME HOOD

TO REMAIN

P H

A S

E

ROOM END USER

G18

G18A

STRUCTURAL MATERIALS EVALUATION LAB

STRUCTURAL MATERIALS EVALUATION LAB

30A

40B

NON-DESTRUCTIVE INSPECTION LAB

ALL

STRUCTURAL FAILURE LAB

STRUCTURAL FAILURE LAB

STRUCTURAL FAILURE LAB

NON-DESTRUCTIVE INSPECTION LAB

NON-DESTRUCTIVE INSPECTION LAB

117 STRUCTURAL MATERIALS EVALUATION LAB

G18M STRUCTURAL MATERIALS EVALUATION LAB

19 STRUCTURAL FAILURE LAB

20 ELECTRICAL FAILURE LAB

28 STRUCTURAL FAILURE LAB

38 NON-DESTRUCTIVE INSPECTION LAB

39 NON-DESTRUCTIVE INSPECTION LAB

40 NON-DESTRUCTIVE INSPECTION LAB

145 STRUCTURAL MATERIALS EVALUATION LAB

P H

A S

E

NEW CAPTURE HOOD

40 NON-DESTRUCTIVE INSPECTION LAB

N

7 8 11 12 13 14 15

L

J

G

40B

30A

30 3129

PH2A-01

PH2A-02

PH2A-02

PH2A-03

PH2A-06

PH2A-07

PH2A-04

PH2A-05

UTILITY

SHAFT 1

UTILITY

SHAFT 3

UTILITY

SHAFT 4

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

C H

E C

K E

D B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

IT

R

R E

V

IE

W B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

R E

N O

V A

T E

R E

S E

A R

C H

L A

B F

O R

R A

P

ID

R E

A C

T

IO

N

W P

A F

B B

U

IL

D

IN

G

W R

IG

H

T P

A T

T E

R S

O N

A F

B O

H

IO

Z H

T V

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B

R O

A D

W A

Y S

T R

E E

T

C

IN

C

IN

N A

T I, O

H

IO

KEY PLAN

SEAL 12-22-22

G-022

F

IR

S T

F L O

O R

P H

A S

IN

G

P L A

N

P H

A S

E

A

J P

E S

S E

L L

M A

L B

E R

S

G H

U T

Z E

L

R S

C H

M

IT

Z

-1

-2

CERTIFIED FINAL - MAR 16, 2023

N 16'4' 8'

SCALE: 1/8"=1'-0"

1/8" = 1'-0"G-022

01 FIRST FLOOR PHASE 2A PLAN

PHASING NOTES

NON-DESTRUCTIVE INSPECTION LAB AND STRUCTURAL FAILURE LAB

NOTE: THE NORTH HALF OF LAB 39 AND THE SOUTH HALF OF LAB 40 SHALL BE COMPLETED AND ACCEPTED BY THE

GOVERNMENT PRIOR TO STARTING CONSTRUCTION ON THE SOUTH HALF OF LAB 39 AND THE NORTH HALF OF LAB 40

PH2A-01 RETAIN TEMPORARY PARTITION IN LOCATION INDICATED UNTIL RENOVATION IS COMPLETE. PROVIDE DOOR TO

ACCESS NEWLY RENOVATED 40 AND 40B

PH2A-02 COMMENCE RENOVATION OF 39, 29, AND NORTH SIDE OF 40 AFTER DEPARTMENT PERSONNEL IS FINISHED

REMOVING DESIGNATED EQUIPMENT

PH2A-03 TEMPORARILY CAP DUCTWORK AND PIPING AND BALANCE SYSTEM FOR LOWER CFM. AFTER CONSTRUCTION ON

THIS PHASE IS COMPLETE, RECONNECT DUCTWORK AND PIPING AND REBALANCE SYSTEM FOR ORIGINAL CFM

AND GPM

PH2A-04 REMOVE EXISTING ACCORDION DOOR AND INSTALL NEW GYPSUM BOARD PARTITION AND DOORS

PH2A-05 CONTRACTOR TO COORDINATE CONSTRUCTION ACTIVITY WITH MOVING EXISTING MPI LINE BY DEPARTMENT

PERSONNEL. EXISTING MPI LINE WILL NOT BE REMOVED FROM THE LAB

PH2A-06 AFTER NEW CONSTRUCTION IS COMPLETED AND ACCEPTED IN LAB 39, DEPARTMENT PERSONNEL TO MOVE

DESIGNATED LAB EQUIPMENT TO RENOVATED 39 AND REMOVE TEMPORARY PARTITION

PH2A-07 AFTER NEW CONSTRUCTION IS COMPLETED AND ACCEPTED IN LAB 40, DEPARTMENT PERSONNEL TO MOVE

DESIGNATED LAB EQUIPMENT TO RENOVATED 40

W

2Q R

R

_P la ns -0

1 HR

N

7 8 9 10

L

J

G

F.b

SCALE: 3/32"=1'-0"

8' 24'16' N

LAB

G18

LAB

G18A

COMMON PATH: 86 FT

FROM MEZZANINE

TRAVEL DIST.: 100 FT

LIMITS OF ROOM B

FOR MEZZANINE AREA B

CALCULATION

CALCULATED OCCUPANT LOAD

FOR ENTIRE FLOOR AT 1 PERSON

PER 100 SQ. FT. PLUS MEZZANINE.

ADDITIONAL EXITS ARE PROVIDED

FROM FLOOR

N

7 8 9 10

L

J

G

F.b

SCALE: 3/32"=1'-0"

8' 24'16' N

MEZZANINE

G18M

COMMON PATH: 86 FT

MEZZANINE AREA A

FOR CALCULATION

MEZZANINE AREA B

FOR CALCULATION

LIMITS OF ROOM A FOR

MEZZANINE AREA A

CALCULATION

INDUSTRIAL USE

1 PERSON / 100 SQUARE FEET

XX = NUMBER OF OCCUPANTS

USING EGRESS COMPONENT

LIFE SAFETY LEGEND

EXIT SIGN

YY = TOTAL EGRESS CAPACITY OF

EGRESS COMPONENT

XX

YY

DIRECTIONAL EXIT SIGN

STORAGE USE

1 PERSON / 500 SQUARE FEET

WALL-MOUNTED FIRE EXTINGUISHER

CABINET WITH CLASS 4A:80B:C FIRE

EXTINGUISHER

1-HOUR FIRE BARRIER

AREA NOT WITHIN SCOPE OF

PROJECT

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M

AR

K D

ES

C

R

IP

TI

O

N

R

EN

O

VA

TE

R

ES

EA

R C

H L

AB

F

O R

R

AP

ID

R

EA

C

TI

O

N W

PA

FB

B U

IL

D

IN

G

W R

IG

H

T

PA

TT

ER

SO

N

A

FB

, O H

IO

ZH

TV

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

BR

O

AD

W

AY

S

TR

EE

T C

IN

C

IN

N

AT

I, O H

IO

KEY PLAN

SEAL

BIM 360://WPAFB Rapid Reaction Lab/682002_FIRE_Central_2020.rvt

3/13/2023 11:42:38 AM

G-101

G R

O U

N D

F

LO

O R

A N

D M

EZ

ZA

N

IN

E

PL

AN

LI

FE

SA

FE

TY

K.

P

O

TH

IE

R

H . M

EA

D

O W

S

W . H

IG

G

IN

S

-1

6-

CERTIFIED FINAL - MAR 16, 2023

3/32" = 1'-0"G-101

01 GROUND FLOOR PLAN - LIFE SAFETY

3/32" = 1'-0"G-101

02 MEZZANINE PLAN - LIFE SAFETY

S U

B M

IT

T

H

U T

Z E

L

W

2Q R

R

_P la ns -0

1 H R

1 HR

1 H R

1 HR

1 H R

1 HR

1 H R

1 HR

1 H R

1 HR

1 H R

1 HR

1 H R

1 HR

1 H R

1 HR

N

7 8 9 10 11 12 13 14 15

L

J

G

F.b

SCALE: 3/32"=1'-0"

8' 24'16' N

FAILURE

ANALYSIS

LAB

ENVIRONMENTAL

TEST LAB

THERMOGRAPHY/

SHEAROGRAPHY

49 UT/EC

FPI/MPI

RADIOGRAPHY

X RAY

40B

UT/EC

FAILURE

ANALYSIS

LAB

STORAGE

FAILURE

ANALYSIS

LAB

FAILURE

ANALYSIS

LAB

LAB

30A

NO CHANGE TO FLOOR

OCCUPANT LOAD TOTAL.

CALCULATED OCCUPANT

LOAD FOR ENTIRE FLOOR

AT 1 PERSON PER 100 SQ. FT.

IS 175 WHICH IS MET USING

ONLY TWO OF THE EXISTING

FIVE EXITS

TRAVEL DISTANCE: 113 FT.

INDUSTRIAL USE

1 PERSON / 100 SQUARE FEET

XX = NUMBER OF OCCUPANTS

USING EGRESS COMPONENT

LIFE SAFETY LEGEND

EXIT SIGN

YY = TOTAL EGRESS CAPACITY OF

EGRESS COMPONENT

XX

YY

DIRECTIONAL EXIT SIGN

STORAGE USE

1 PERSON / 500 SQUARE FEET

WALL-MOUNTED FIRE EXTINGUISHER

CABINET WITH CLASS 4A:80B:C FIRE

EXTINGUISHER

1-HOUR FIRE BARRIER

AREA NOT WITHIN SCOPE OF

PROJECT

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M

AR

K D

ES

C

R

IP

TI

O

N

R

EN

O

VA

TE

R

ES

EA

R C

H L

AB

F

O R

R

AP

ID

R

EA

C

TI

O

N W

PA

FB

B U

IL

D

IN

G

W R

IG

H

T

PA

TT

ER

SO

N

A

FB

, O H

IO

ZH

TV

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

BR

O

AD

W

AY

S

TR

EE

T C

IN

C

IN

N

AT

I, O H

IO

KEY PLAN

SEAL

BIM 360://WPAFB Rapid Reaction Lab/682002_FIRE_Central_2020.rvt

3/13/2023 11:42:47 AM

G-102

FI

R

ST

F

LO

O

R P

LA

N

LI

FE

S

AF

ET

Y

K.

P

O

TH

IE

R

H . M

EA

D

O W

S

W . H

IG

G

IN

S

-1

6-

CERTIFIED FINAL - MAR 16, 2023

3/32" = 1'-0"G-102

01 FIRST FLOOR PLAN - LIFE SAFETY

S U

B M

IT

T

H

U T

Z E

L

W

2Q R

R

_P la ns -0

1 H R

1 H R

1 HR

1 HR

1 H R

1 H R

1 HR

1 HR

1 H R

1 H R

1 HR

1 HR

1 H R

1 H R

1 HR

N

7 8 9 10 11 12 13 14 15

L

J

G

F.b

SCALE: 3/32"=1'-0"

8' 24'16' N

LAB

LAB

NO CHANGE TO FLOOR

OCCUPANT LOAD TOTAL.

CALCULATED OCCUPANT

LOAD FOR ENTIRE FLOOR

AT 1 PERSON PER 100 SQ. FT.

IS 175 WHICH IS MET USING

ONLY TWO OF THE EXISTING

FOUR EXITS

INDUSTRIAL USE

1 PERSON / 100 SQUARE FEET

XX = NUMBER OF OCCUPANTS

USING EGRESS COMPONENT

LIFE SAFETY LEGEND

EXIT SIGN

YY = TOTAL EGRESS CAPACITY OF

EGRESS COMPONENT

XX

YY

DIRECTIONAL EXIT SIGN

STORAGE USE

1 PERSON / 500 SQUARE FEET

WALL-MOUNTED FIRE EXTINGUISHER

CABINET WITH CLASS 4A:80B:C FIRE

EXTINGUISHER

1-HOUR FIRE BARRIER

AREA NOT WITHIN SCOPE OF

PROJECT

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M

AR

K D

ES

C

R

IP

TI

O

N

R

EN

O

VA

TE

R

ES

EA

R C

H L

AB

F

O R

R

AP

ID

R

EA

C

TI

O

N W

PA

FB

B U

IL

D

IN

G

W R

IG

H

T

PA

TT

ER

SO

N

A

FB

, O H

IO

ZH

TV

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

BR

O

AD

W

AY

S

TR

EE

T C

IN

C

IN

N

AT

I, O H

IO

KEY PLAN

SEA…