This file contains architectural drawings and specifications for an Indiana Air National Guard Small Arms Range facility in Terre Haute, Indiana. The drawings include building elevations, door schedules, window details, reflected ceiling plans, and finish plans for a single-story structure containing an arms range, classroom, weapons maintenance area, and support spaces.

Key architectural details include: pre-finished metal roof panels in white, ballistic-rated doors and windows, ATFP-compliant aluminum storefront systems, exterior safety yellow paint (Pantone PQ137C) for bollards and railings, continuous suspended sawtooth ballistic baffle ceiling system in the range area, and various door types including hollow metal and aluminum frames. The facility features specialized spaces like a bullet trap room, RSO station, ACP vestibules, and mechanical areas. Interior finishes include acoustic ceilings, raised access flooring, and storage lockers. The building incorporates force protection measures through ballistic-rated materials and ATFP-compliant openings. Building dimensions indicate ceiling heights of 9'-0" to 11'-0" with a wainscot height of 103'-4" and total wall height of 113'-4".

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXTERIOR FINISHES SCHEDULE

• PRE-FINISHED METAL ROOF PANEL.

COLOR: WHITE

• PRE-FINISHED METAL WALL PANEL.

COLOR: .

• PRE-FINISHED METAL LINER PANEL.

COLOR: .

• PRE-FINISHED METAL GUTTER.

COLOR: .

• PRE-FINISHED METAL DOWNSPOUT.

COLOR: .

• PRE-FINISHED METAL RIDGE TRIM.

COLOR: .

• PRE-FINISHED METAL EAVE TRIM.

COLOR: .

• PRE-FINISHED METAL RAKE TRIM.

COLOR: .

• PRE-FINISHED METAL OUTSIDE CORNER TRIM.

COLOR: .

• PRE-FINISHED METAL INSIDE CORNER TRIM.

COLOR: .

• PRE-FINISHED METAL BASE TRIM.

COLOR: .

• PRE-FINISHED METAL FRAMED OPENING TRIM.

COLOR: .

• PAINTED HOLLOW METAL WINDOW FRAME.

COLOR: .

• EXTERIOR INSULATION FINISH SYSTEM (EIFS).

COLOR: .

• PRE-FINISHED METAL LOUVER.

COLOR: .

• PAINTED HOLLOW METAL DOOR.

COLOR: .

• PAINTED HOLLOW METAL DOOR FRAME.

COLOR: .

• PAINTED STEEL BOLLARD.

COLOR: PANTONE PQ137C - SAFETY YELLOW

• PAINTED EXPOSED CONCRETE

COLOR: .

• PAINTED EXTERIOR RAILING.

COLOR: PANTONE PQ137C - SAFETY YELLOW

• GLAZING.

LIGHT GRAY EXTERIOR PANE.

CLEAR INTERIOR PANE.

GENERAL NOTES

1. THESE DRAWINGS ARE NOT TO BE SCALED. REFER TO DIMENSIONS

INDICATED ON DIMENSION PLANS, SHOP DRAWINGS, OR ESTABLISHED

FIELD DIMENSIONS. WHERE NO DIMENSIONS OR METHOD OF

DETERMINING A LOCATION IS GIVEN, VERIFY WITH ARCHITECT PRIOR TO

PROCEEDING.

2. VERIFY EQUIPMENT REQUIREMENTS FOR ROUGH-IN AND UTILITY

CONNECTIONS PRIOR TO CONSTRUCTION TO ASSURE THAT PROPER

BLOCKING, OPENINGS, AND UTILITY CONNECTIONS ARE PROVIDED.

3. IN ALL CONTINUOUS, UNINTERRUPTED GYPSUM BOARD CEILINGS,

PROVIDE CONTROL JOINTS AT INTERVALS SPECIFIED (BUT NOT GREATER

THAN 30 FEET). VERIFY LOCATIONS WITH ARCHITECT PRIOR TO

PROCEEDING.

4. PROVIDE PROPER SEPARATION BETWEEN ALL DISSIMILAR MATERIALS.

5. EQUIPMENT SHOWN IN DRAWINGS IS FOR LAYOUT AND COORDINATION

PURPOSES.

6. FURNITURE IS SHOWN IN DRAWINGS IS FOR LAYOUT AND COORDINATION

PURPOSES.

7. PROVIDE ABOVE CEILING STRUCTURAL SUPPORT FOR ALL CEILING

MOUNTED EQUIPMENT.

8. DIMENSIONS IN PLANS ARE TYPICALLY SHOWN TO:

A. COLUMN CENTERLINES.

B. FACE OF UNIT MASONRY OR CONCRETE.

C. FACE OF FRAMING WALLS.

D. FACE OF INTERIOR PARTITIONS (FACE OF CMU,

IMP, MTL PANEL, STUD)

NOTE: WALL WITH APPLIED FINISHES ARE DIMENSIONED TO

REFERENCES ABOVE U.O.N.

9. DIMENSIONS IN ELEVATIONS/ SECTIONS ARE TYPICALLY SHOWN TO:

A. TOP OF STEEL

B. TOP OF TILT-UP/ CAST-IN-PLACE CONCRETE, UNIT MASONRY.

C. FLOOR SLAB/ LEVEL FLOOR.

D. APPROXIMATE ROOF FINISHED ELEVATION

KEYED PLAN

FIRST FLOOR

100' - 0"

WAINSCOT

103' - 4"

TOP OF TILT-UP WALL

113' - 4"

3 2

W1 W1 W1 102-A 115-F 115-E 115-D

104104 104

116 120 120120115

114 114 114

FIRST FLOOR

100' - 0"

WAINSCOT

103' - 4"

TOP OF TILT-UP WALL

113' - 4"

115-B 115-A W1

104-A 105-A

116120 120

KEYED NOTES

101 PRE-FINISHED METAL ROOF PANEL.

102 PRE-FINISHED METAL FASCIA TRIM

103 PRE-FINISHED METAL OPEN FACED DOWNSPOUT.

104 PRE-FINISHED METAL GUTTER.

111 PRE-FINISHED METAL CAP TRIM.

112 PRE-FINISHED METAL RIDGE TRIM.

113 ATFP COMPLIANT INSULATED HOLLOW METAL DOOR AND FRAME.

114 ATFP COMPLIANT FIXED ALUMINUM WINDOW.

115 ATFP COMPLIANT ALUMINUM STOREFRONT SYSTEM.

116 MASONRY VENEER.

119 PRE-CAST CONCRETE SPLASHBLOCK.

120 BALLISTIC RATED INSULATED HOLLOW METAL DOOR AND FRAME.

121 EXTERIOR INSULATION FINISH SYSTEM (EIFS).

KEYED NOTES ARE REFERENCED BY ELEVATION SHEETS.

FIRST FLOOR

100' - 0"

FIRST FLOOR

100' - 0"

WAINSCOT

103' - 4"

WAINSCOT

103' - 4"

TOP OF TILT-UP WALL

113' - 4"

TOP OF TILT-UP WALL

113' - 4"

A CB

W1 W1 W1 W1

119119

104 104

103 103 121121

103 103

102114 114114 114

111 111

119 119

FIRST FLOOR

100' - 0"

FIRST FLOOR

100' - 0"

WAINSCOT

103' - 4"

WAINSCOT

103' - 4"

TOP OF TILT-UP WALL

113' - 4"

TOP OF TILT-UP WALL

113' - 4"

AC B

115-C

104104

104102

111 111

SHEET ID

D E

S

IG

N B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

J R

P L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A

T E

R R

E H

A U

T E

, I N

D

IA

N A

IN

ID

IA

N

A A

IR

N

A T

IO

N

A L

G U

A R

D A

N G

S M

A

LL

A R

M S

R A

N G

E C

O N

T R

A C

T

P

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

US Army Corps of Engineers ®

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

S

IZ

E

A N

S I D

P R E

LIM

IN

A R Y

N O

T F O R

C

N S

TR

U C

TIO

N

14000 QUAIL SPRINGS PARKWAY

SUITE 500

OKLAHOMA CITY, OK 73134

T: 405-478-5353

P R

O J E

C T

N O

A-201

M N

O B

E R

T

M N

O B

E R

T

C B

U N

A L

D M

O T

L E

Y

B U

IL

D

IN

G

E

LE

V A

T

IO

N S

A R

C H

IT

E

C T

U R

A L

CERTIFIED FINAL SUBMITTAL - DESIGN BUILD RFP

3/32" = 1'-0"1

BUILDING ELEVATION - NORTH

3/32" = 1'-0"2

BUILDING ELEVATION - SOUTH

N

MCSATS CATM

KEY PLAN

3/32" = 1'-0"3

BUILDING ELEVATION - EAST

3/32" = 1'-0"4

BUILDING ELEVATION - WEST

SCALE IN FEET - 3/32" = 1'-0"

8' 4' 0' 8' 24'16'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

A

M E

N D

M E

N T

W

2Q R

-2

7A _C

ER

TF

in al

_P la ns -0

DOOR SCHEDULE NOTES

1. INSULATED DOOR AND FRAME.

2. INSULATED COILING OVERHEAD DOOR.

3. EXIT ONLY DOOR.

4. BUILDING ACCESS CONTROLS.

DOOR SCHEDULE ABBREVIATIONS

INTR INTERIOR

EXTR EXTERIOR

SG SINGLE DOOR

DA DOUBLE ACTING

DD DOUBLE DOOR

DE DOUBLE EGRESS

SL SLIDER

OH OVERHEAD DOOR

IM INSULATED METAL

HM HOLLOW METAL

WD WOOD

AL ALUMINUM

STL STEEL

FL FLUSH

NV NARROW VIEW

HV HALF VIEW

FV FULL VIEW

PV PORTAL VIEW

SS STAINLESS STEEL

SSL SINGLE SIDE LITE

DS DOUBLE SIDE LITE

NVC NARROW VIEW CENTERED

LO LOUVER

GLAZING SCHEDULE

G1 1" INSULATED GLAZING

G2 1/4" CLEAR TEMPERED GLAZING.

G3 BALLISTIC RATED.

G4 CERTIFIED BLAST RESISTANT 1" INSULATED GLAZING UNIT. GLASS TO BE

1/4" NOMINAL LAMINTED GLASS CONSISTING OF TWO 1/8" NOMINAL

GLASS PANES BONDED TOGETHER WITH A MINIMUM OF A 0.030"

INTERLAYER OF A MATERIAL DESIGN FOR BLAST RESISTANCE. THE

GLAZING FRAME BIT SHALL BE IN ACCORDANCE WITH ASTM 2248.

DOOR SCHEDULE NOMENCLATURE

FLUSH DOOR (DESIGN F)

THE TERM “FLUSH,” WHEN USED TO DESCRIBE A DOOR TYPE, REFERS TO A

DOOR WITHOUT LITES OR LOUVERS.

FULL FLUSH DOOR

FEATURES NO VISIBLE SEAMS ON THE SURFACE OF THE FACES. FULL HEIGHT

VERTICAL SEAMS ARE VISIBLE ON DOOR EDGES.

SEAMLESS DOOR

FEATURES NO VISIBLE SEAMS EITHER ON THE FACE OR ALONG THE VERTICAL

EDGES OF THE DOOR.

STILE AND RAIL OR STILE AND PANEL DOOR

STILE AND RAIL ARE EITHER MITERED OR BUTTED. MITERED JOINTS ARE

WELDED AND GROUND SMOOTH, SUCH THAT NO MITER JOINTS APPEAR ON THE

DOOR FACES. BUTTED JOINT SEAMS SHALL REMAIN VISIBLE. THE PANELS ARE

INTERLOCKED WITH STILES AND RAILS AND THEY MAY BE FLUSH OR RECESSED

WITH PERIMETER SURFACES.

HALF GLASS DOORS (DESIGN G)

THE SIZE AND LOCATION FROM THE FINISHED FLOOR TO THE GLAZED OPENING

WILL VARY WITH THE MANUFACTURER. THEIR LITERATURE SHOULD BE

CONSULTED TO DETERMINE THIS INFORMATION AS WELL AS RECOMMENDED

GLASS SIZES. MULTIPLE LITE PATTERNS ARE CREATED BY THE INSTALLATION

OF MUNTINS.

DOORS WITH LITES ARE DESIGNED TO ACCEPT GLAZING MATERIAL OF VARIOUS

THICKNESSES.

IN ACCORDANCE WITH THE ARCHITECTURAL BARRIERS ACT (ABA), DOORS

CONTAINING ONE OR MORE GLAZING PANELS SHALL HAVE THE BOTTOM OF AT

LEAST ONE GLASS PANEL A MAXIMUM OF 43" FROM THE FINISHED FLOOR.

FULL GLASS DOORS (DESIGN FG)

A MAXIMUM 7" RAIL AND STILE OCCUR AT THE TOP AND AT THE VERTICAL EDGES

OF THIS DOOR. AN 8" MINIMUM RAIL OCCURS AT THE BOTTOM.

TO COMPLY WITH THE ARCHITECTURAL BARRIERS ACT (ABA), THE BOTTOM RAIL

SHALL BE SPECIFIED AS MINIMUM 10” MEASURED VERTICALLY FROM THE FLOOR

AND SHALL BE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL

WIDTH OF THE DOOR. MUNTINS ARE NORMALLY USED TO CREATE THE

MULTIPLE LITE FG3 UNIT, ALTHOUGH A 5"-5 1/2" WELDED-IN RAIL IS STANDARD

WITH SOME DOOR MANUFACTURERS. CONSULT INDIVIDUAL MANUFACTURER’S

LITERATURE FOR THEIR DESIGN VARIATIONS.

NARROW LITE DOOR (DESIGN N)

THE GLASS CUTOUT IN THESE DOORS OCCURS NEAR THE LOCK STILE. THE

WIDTH OF THE LITE SHALL BE A MINIMUM OF 3" AND THE HEIGHT VARIES

BETWEEN 10" AND 60". CONSULT THE INDIVIDUAL MANUFACTURER’S

LITERATURE FOR THE NARROW LITE STANDARD SPECIFICATION IN THEIR

PROGRAM.

VISION LITE DOOR (DESIGN V)

THE INDUSTRY STANDARD IS A 10" X 10" LITE ON THE VERTICAL CENTERLINE OF

THE DOOR. THE HORIZONTAL CENTERLINE OF THE LITE WILL VARY FROM 60" TO

66" FROM THE FINISHED FLOOR. CONSULT THE INDIVIDUAL MANUFACTURER’S

LITERATURE FOR DETAILS. THE “V” DOOR DOES NOT COMPLY WITH THE

ARCHITECTURAL BARRIERS ACT (ABA). TO SATISFY THIS REQUIREMENT A

NARROW LITE (N) SHALL BE USED.

LOUVERED DOOR (DESIGN L)

AS INDICATED BY THE ASTERISK NOTE, THERE ARE A NUMBER OF LOUVERS AND

GRILLES AVAILABLE. THE CHOICE OF WHICH ONE TO USE MUST BE DETERMINED

BY THE ARCHITECT ON AESTHETIC, FUNCTIONAL AND ECONOMIC GROUNDS AS

WELL AS FIRE PROTECTION.

A LOUVER IS AN OPENING IN THE DOOR WITH A SERIES OF SLATS OR BLADES TO

ALLOW PASSAGE OF AIR. GENERALLY, LOUVERS ARE PREFABRICATED BY

WELDING OR TENONING THE BLADES TO THE MOULDING FRAME. THIS LOUVER

FRAME IS INSERTED INTO THE OPENING IN THE DOOR PREPARE TO RECEIVE

THE LOUVER. FUSIBLE LINK LOUVERS ARE USED TO CONTROL PASSAGE OF

FLAMES AND HEAT. THESE ARE INSERTED INTO FIRE RATED DOORS. CONSULT

INDIVIDUAL MANUFACTURER’S LITERATURE FOR DETAILS.

DUTCH DOOR (DESIGN D)

UNLESS SPECIFIED OTHERWISE, THE DUTCH DOOR IS FURNISHED WITHOUT A

SHELF. THIS ACCESSORY IS AVAILABLE, HOWEVER, FROM ALL

MANUFACTURERS. THE SHELF HEIGHT MAY VARY FROM 36" TO 42" FROM THE

FINISHED FLOOR. CONSULT THE INDIVIDUAL MANUFACTURER’S LITERATURE IF

THIS IS CRITICAL.

TO COMPLY WITH THE ARCHITECTURAL BARRIERS ACT (ABA), THE SHELF

HEIGHT SHALL BE 36" MAXIMUM FROM THE FINISHED FLOOR.

COORDINATE WITH

WIDTH OF DOOR

C O

O R

D

IN

A T

E W

IT

H

H

IE

G H

T O

F D

O O

R

2" H

E A

D A

N D

JA

M

B

F1

DOOR FRAME TYPES

COORDINATE WITH

WIDTH OF DOOR

C O

O R

D

IN

A T

E W

IT

H

H

IE

G H

T O

F D

O O

R

2" H

E A

D A

N D

JA

M

B

F2

COORDINATE WITH

WIDTH OF DOOR

C O

O R

D

IN

A T

E W

IT

H

H

IE

G H

T O

F D

O O

R

4" H

E A

D A

N D

JA

M

B

F3

COORDINATE WITH

WIDTH OF DOOR

C O

O R

D

IN

A T

E W

IT

H

H

IE

G H

T O

F D

O O

R

4" H

E A

D A

N D

JA

M

B

F4

COORDINATE WITH

WIDTH OF DOOR

C O

O R

D

IN

A T

E W

IT

H

H

IE

G H

T O

F D

O O

R

2" H

E A

D A

N D

JA

M

B

F5

G4

8'

4' - 8"

D1

DOOR TYPES

D2 D3 D4 D5 D6 D7 D8

DESIGN F DESIGN F DESIGN N DESIGN N DESIGN G DESIGN G DESIGN FG DESIGN FG

WINDOW TYPES

W1

4' - 0"

G4

2" H

E A

D

JA

M

B

S

IL

L

W2

4' - 0"

G3

2" H

E A

D

JA

M

B

S

IL

L 4'

2'

W3

18' - 8"

G3

2" H

E A

D

JA

M

B

S

IL

L 4'

8'

8'

8'

GENERAL NOTES

1. THESE DRAWINGS ARE NOT TO BE SCALED. REFER TO DIMENSIONS

INDICATED ON DIMENSION PLANS, SHOP DRAWINGS, OR ESTABLISHED

FIELD DIMENSIONS. WHERE NO DIMENSIONS OR METHOD OF

DETERMINING A LOCATION IS GIVEN, VERIFY WITH ARCHITECT PRIOR TO

PROCEEDING.

2. VERIFY EQUIPMENT REQUIREMENTS FOR ROUGH-IN AND UTILITY

CONNECTIONS PRIOR TO CONSTRUCTION TO ASSURE THAT PROPER

BLOCKING, OPENINGS, AND UTILITY CONNECTIONS ARE PROVIDED.

3. IN ALL CONTINUOUS, UNINTERRUPTED GYPSUM BOARD CEILINGS,

PROVIDE CONTROL JOINTS AT INTERVALS SPECIFIED (BUT NOT GREATER

THAN 30 FEET). VERIFY LOCATIONS WITH ARCHITECT PRIOR TO

PROCEEDING.

4. PROVIDE PROPER SEPARATION BETWEEN ALL DISSIMILAR MATERIALS.

5. EQUIPMENT SHOWN IN DRAWINGS IS FOR LAYOUT AND COORDINATION

PURPOSES.

6. FURNITURE IS SHOWN IN DRAWINGS IS FOR LAYOUT AND COORDINATION

PURPOSES.

7. PROVIDE ABOVE CEILING STRUCTURAL SUPPORT FOR ALL CEILING

MOUNTED EQUIPMENT.

8. DIMENSIONS IN PLANS ARE TYPICALLY SHOWN TO:

A. COLUMN CENTERLINES.

B. FACE OF UNIT MASONRY OR CONCRETE.

C. FACE OF FRAMING WALLS.

D. FACE OF INTERIOR PARTITIONS (FACE OF CMU,

IMP, MTL PANEL, STUD)

NOTE: WALL WITH APPLIED FINISHES ARE DIMENSIONED TO

REFERENCES ABOVE U.O.N.

9. DIMENSIONS IN ELEVATIONS/ SECTIONS ARE TYPICALLY SHOWN TO:

A. TOP OF STEEL

B. TOP OF TILT-UP/ CAST-IN-PLACE CONCRETE, UNIT MASONRY.

C. FLOOR SLAB/ LEVEL FLOOR.

D. APPROXIMATE ROOF FINISHED ELEVATION

SHEET ID

D E

S

IG

N B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

J R

P L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A

T E

R R

E H

A U

T E

, I N

D

IA

N A

IN

ID

IA

N

A A

IR

N

A T

IO

N

A L

G U

A R

D A

N G

S M

A

LL

A R

M S

R A

N G

E C

O N

T R

A C

T

P

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

US Army Corps of Engineers ®

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

S

IZ

E

A N

S I D

P R E

LIM

IN

A R Y

N O

T F

N S

TR

U C

TIO

N

14000 QUAIL SPRINGS PARKWAY

SUITE 500

OKLAHOMA CITY, OK 73134

T: 405-478-5353

P R

O J E

C T

N O

A-610

M N

O B

E R

T

M N

O B

E R

T

C B

U N

A L

D M

O T

L E

Y

D O

O R

S C

H E

D U

L E

A R

C H

IT

E

C T

U R

A L

CERTIFIED FINAL SUBMITTAL - DESIGN BUILD RFP

DOOR SCHEDULE - FIRST FLOOR

DOOR

NUMBER

DOOR FRAME

STC RATING FIRE RATING HARDWARE

DETAILS

NOTESTYPE WIDTH HEIGHT THICKNESS GLAZING MATERIAL TYPE MATERIAL HEAD JAMB THRESHOLD

102-A D7 3' - 0" 7' - 0" 1 3/4" AL F5 AL 4

104-A D7 3' - 0" 7' - 0" 1 3/4" AL F5 AL 4

104-B D7 3' - 0" 7' - 0" 1 3/4" AL F5 AL

105-A D2 6' - 0" 7' - 0" 1 3/4" HM F4 HM 1, 4

106-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 90 4

106-B D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 4

107-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 90 4

108-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 90 4

108-B D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 4

109-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 4

110-A D3 3' - 0" 7' - 0" 1 3/4" HM F3 HM 4

111-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM

112-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM

113-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM

114-A D3 3' - 0" 7' - 0" 1 3/4" HM F3 HM

115-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 1, 3

115-B D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 1, 3

115-C D2 6' - 0" 7' - 0" 1 3/4" HM F4 HM 1

115-D D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 1, 4

115-E D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 1, 3

115-F D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 1, 3

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

A

M E

N D

M E

N T

W

2Q R

-2

7A _C

ER

TF

in al

_P la ns -0

A A

C C

B B

A-201

A-201

11' - 0"

9' - 0"

9' - 0"

9' - 0"

11' - 0"

11' - 0" 9' - 0"

9' - 0"

9' - 0"

9' - 0"

EXPOSED

A-201

A-201

ARMS RANGE

BULLET TRAP

RSO

ACP VESTIBULE

ACP VESTIBULE

RANGE STORAGE

109 9' - 0"

JANITOR

TOILET WITH

SHOWER

TOILET

CORRIDOR

WEAPONS MX AND

CLEANING

CLASSROOM

MECHANICAL

CORRIDOR

ENTRY VESTIBULE

107 107

107107108 106

108106

107107107107

107107107107

101101101101101101101101101

OPEN TO

STRUCTURE ABOVE

11' - 0"

9' - 0"

9' - 0"

GENERAL NOTES

1. THESE DRAWINGS ARE NOT TO BE SCALED. REFER TO DIMENSIONS

INDICATED ON DIMENSION PLANS, SHOP DRAWINGS, OR ESTABLISHED

FIELD DIMENSIONS. WHERE NO DIMENSIONS OR METHOD OF

DETERMINING A LOCATION IS GIVEN, VERIFY WITH ARCHITECT PRIOR TO

PROCEEDING.

2. VERIFY EQUIPMENT REQUIREMENTS FOR ROUGH-IN AND UTILITY

CONNECTIONS PRIOR TO CONSTRUCTION TO ASSURE THAT PROPER

BLOCKING, OPENINGS, AND UTILITY CONNECTIONS ARE PROVIDED.

3. IN ALL CONTINUOUS, UNINTERRUPTED GYPSUM BOARD CEILINGS,

PROVIDE CONTROL JOINTS AT INTERVALS SPECIFIED (BUT NOT GREATER

THAN 30 FEET). VERIFY LOCATIONS WITH ARCHITECT PRIOR TO

PROCEEDING.

4. PROVIDE PROPER SEPARATION BETWEEN ALL DISSIMILAR MATERIALS.

5. EQUIPMENT SHOWN IN DRAWINGS IS FOR LAYOUT AND COORDINATION

PURPOSES.

6. FURNITURE IS SHOWN IN DRAWINGS IS FOR LAYOUT AND COORDINATION

PURPOSES.

7. PROVIDE ABOVE CEILING STRUCTURAL SUPPORT FOR ALL CEILING

MOUNTED EQUIPMENT.

8. DIMENSIONS IN PLANS ARE TYPICALLY SHOWN TO:

A. COLUMN CENTERLINES.

B. FACE OF UNIT MASONRY OR CONCRETE.

C. FACE OF FRAMING WALLS.

D. FACE OF INTERIOR PARTITIONS (FACE OF CMU,

IMP, MTL PANEL, STUD)

NOTE: WALL WITH APPLIED FINISHES ARE DIMENSIONED TO

REFERENCES ABOVE U.O.N.

9. DIMENSIONS IN ELEVATIONS/ SECTIONS ARE TYPICALLY SHOWN TO:

A. TOP OF STEEL

B. TOP OF TILT-UP/ CAST-IN-PLACE CONCRETE, UNIT MASONRY.

C. FLOOR SLAB/ LEVEL FLOOR.

D. APPROXIMATE ROOF FINISHED ELEVATION

KEYED PLAN

KEYED NOTES

KEYED NOTES ARE REFERENCED BY THIS SHEET.

101 CONTINUOUS SUSPENDED SAWTOOTH BALLISTIC BAFFLE CEILING

SYSTEM.

102 SUSPENDED ACOUSTICAL CEILING.

103 SLOPED SUSPENDED ACOUSTICAL CEILING.

104 TARGET RETRIEVER.

105 CONTINUOUS SUSPENDED BALLISTIC CEILING.

106 PRE-FINISHED METAL SOFFIT PANEL.

107 PRE-FINISHED METAL OPEN FACED DOWNSPOUT.

108 PRE-FINISHED METAL GUTTER.

SHEET ID

D E

S

IG

N B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

J R

P L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A

T E

R R

E H

A U

T E

, I N

D

IA

N A

IN

ID

IA

N

A A

IR

N

A T

IO

N

A L

G U

A R

D A

N G

S M

A

LL

A R

M S

R A

N G

E C

O N

T R

A C

T

P

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

US Army Corps of Engineers ®

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

S

IZ

E

A N

S I D

P R E

LIM

IN

A R Y

N O

T F

N S

TR

U C

TIO

N

14000 QUAIL SPRINGS PARKWAY

SUITE 500

OKLAHOMA CITY, OK 73134

T: 405-478-5353

P R

O J E

C T

N O

A-710

M N

O B

E R

T

M N

O B

E R

T

C B

U N

A L

D M

O T

L E

Y

F

IR

S T

F L

O O

R R

E F

LE

C

T E

D C

E

IL

IN

G

P

LA

N

A R

C H

IT

E

C T

U R

A L

CERTIFIED FINAL SUBMITTAL - DESIGN BUILD RFP

3/32" = 1'-0"1

FIRST FLOOR REFLECTED CEILING PLAN

N

MCSATS CATM

KEY PLAN

SCALE IN FEET - 3/32" = 1'-0"

8' 4' 0' 8' 24'16'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

A

M E

N D

M E

N T

W

2Q R

-2

7A _C

ER

TF

in al

_P la ns -0

ARMS RANGE

MECHANICAL YARD

MECHANICAL YARD

MECHANICAL YARD

I-

I-

NO FURNITURE THIS SECTOR

E1

C

C

A

E1

C

E2 E2 E2

C C

E1

C

E2

E2

E2 E1

C

KEYED PLAN

GENERAL NOTES

1. REFER TO I-601 FOR FINISH ABBREVIATIONS AND

SPECIFICATIONS.

2. SOME MATERIALS AND/OR FINISHES MAY NOT APPEAR ON

THIS SHEET. REFER TO INTERIOR ROOM FINISH SCHEDULE

ON I-601, FOR FINISH INFORMATION.

3. FURNITURE LAYOUT IS BEING SHOWN FOR COORDINATION

PURPOSES ONLY AND WILL BE A BID OPTION TO THE

CONTRACT.

4. PROVIDE MANUAL WINDOW SHADES WHERE MARKED WITH

KEYED NOTE #1 ON PLANS.

INTERIOR FINISH KEYED NOTES AND CODES

WS-1: WINDOW SHADES (MANUAL) - REFER TO ARCHITECTURAL

DETAILS FOR MORE INFORMATION.

LK-1: (15) DOUBLE-TIER LOCKERS, 78"H

RAF (RAISED ACCESS FLOORING) - REFER TO ARCHITECTURAL

PLANS FOR MORE INFORMATION.

SWC-1: SHOWER CURTAIN

SIGNAGE LEGEND

KEYNOTE INDICATES SIGN TYPE

SIGN TYPES

A ROOM IDENTIFICATION SIGN

C EXIT PLAQUE

D1 ALL GENDER PUBLIC SERVICE TOILET, ADA SIGN

D2 UNISEX TOILET & SHOWER SIGN

E1 EXTERIOR REGULATORY NO SMOKING SIGN

E2 EXTERIOR ROOM IDENTIFICATION SIGN

X

SHEET ID

D E

S

IG

N B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

J R

P L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A

T E

R R

E H

A U

T E

, I N

D

IA

N A

IN

ID

IA

N

A A

IR

N

A T

IO

N

A L

G U

A R

D A

N G

S M

A

LL

A R

M S

R A

N G

E C

O N

T R

A C

T

P

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

US Army Corps of Engineers ®

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

S

IZ

E

A N

S I D

P R E

LIM

IN

A R Y

N O

T F

N S

TR

U C

TIO

N

14000 QUAIL SPRINGS PARKWAY

SUITE 500

OKLAHOMA CITY, OK 73134

T: 405-478-5353

P R

O J E

C T

N O

I-111

A

S C

H L E

P P

K

H A

Y E

S

K

H A

Y E

S

D

M O

T L E

Y

F

IR

S T

F L

O O

R F

IN

IS

H P

LA

N

S

E C

T O

R

IN

T

E R

IO

R

S

CERTIFIED FINAL SUBMITTAL - DESIGN BUILD RFP

1/8" = 1'-0"1

FIRST FLOOR FINISH PLAN - SECTOR 1

N

MCSATS CATM

KEY PLAN

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

A

M E

N D

M E

N T

(BID OPTION)1

W

2Q R

-2

7A _C

ER

TF

in al

_P la ns -0

KEYED PLAN

ACP VESTIBULE

RSO

ACP VESTIBULE

RANGE STORAGE

ENTRY VESTIBULE

WEAPONS MX AND

CLEANING

CLASSROOM

114JANITOR

TOILET WITH

SHOWER

TOILET

MECHANICAL

CORRIDOR

CORRIDOR

I-

I-

T1

T1

T1

T1 T1

T1

T1

T1 T1

T1

T1

T1

QTY:12

M1

G1

G1

G1

C1

C

C

A

E1

A

A

D2

AA

D1

A

A

M2

M2

M2

1 1 1

M3

E1

C

E1

C

E1

E2

E2

GENERAL NOTES

1. REFER TO I-601 FOR FINISH ABBREVIATIONS AND

SPECIFICATIONS.

2. SOME MATERIALS AND/OR FINISHES MAY NOT APPEAR ON

THIS SHEET. REFER TO INTERIOR ROOM FINISH SCHEDULE

ON I-601, FOR FINISH INFORMATION.

3. FURNITURE LAYOUT IS BEING SHOWN FOR COORDINATION

PURPOSES ONLY AND WILL BE A BID OPTION TO THE

CONTRACT.

4. PROVIDE MANUAL WINDOW SHADES WHERE MARKED WITH

KEYED NOTE #1 ON PLANS.

INTERIOR FINISH KEYED NOTES AND CODES

WS-1: WINDOW SHADES (MANUAL) - REFER TO ARCHITECTURAL

DETAILS FOR MORE INFORMATION.

LK-1: (15) DOUBLE-TIER LOCKERS, 78"H

RAF (RAISED ACCESS FLOORING) - REFER TO ARCHITECTURAL

PLANS FOR MORE INFORMATION.

SWC-1: SHOWER CURTAIN

SIGNAGE LEGEND

KEYNOTE INDICATES SIGN TYPE

SIGN TYPES

A ROOM IDENTIFICATION SIGN

C EXIT PLAQUE

D1 ALL GENDER PUBLIC SERVICE TOILET, ADA SIGN

D2 UNISEX TOILET & SHOWER SIGN

E1 EXTERIOR REGULATORY NO SMOKING SIGN

E2 EXTERIOR ROOM IDENTIFICATION SIGN

X

SHEET ID

D E

S

IG

N B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

J R

P L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A

T E

R R

E H

A U

T E

, I N

D

IA

N A

IN

ID

IA

N

A A

IR

N

A T

IO

N

A L

G U

A R

D A

N G

S M

A

LL

A R

M S

R A

N G

E C

O N

T R

A C

T

P

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

US Army Corps of Engineers ®

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

S

IZ

E

A N

S I D

P R E

LIM

IN

A R Y

N O

T F

N S

TR

U C

TIO

N

14000 QUAIL SPRINGS PARKWAY

SUITE 500

OKLAHOMA CITY, OK 73134

T: 405-478-5353

P R

O J E

C T

N O

I-112

A

S C

H L E

P P

K

H A

Y E

S

K

H A

Y E

S

D

M O

T L E

Y

F

IR

S T

F L

O O

R F

IN

IS

H P

LA

N

S

E C

T O

R

IN

T

E R

IO

R

S

CERTIFIED FINAL SUBMITTAL - DESIGN BUILD RFP

N

MCSATS CATM

KEY PLAN

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

1/8" = 1'-0"1

FIRST FLOOR FINISH PLAN - SECTOR 2

FURNITURE SCHEDULE

CODE DESCRIPTION COUNT

C1 TRAINING CHAIR 12

G1 STORAGE SHELVING - 24"D X 36"W X

78"H

M1 TACK BOARD 1

M2 TRASH RECEPTACLE - 23 GAL. 3

M3 ENTRY MAT, 4' X 6' 1

T1 TABLE - 24" X 42" 12

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

A

M E

N D

M E

N T

(BID OPTION)1

W

2Q R

-2

7A _C

ER

TF

in al

_P la ns -0

EXTERIOR FINISHES SCHEDULE

• PRE-FINISHED METAL ROOF PANEL.

COLOR: WHITE

• PRE-FINISHED METAL WALL PANEL.

COLOR: .

• PRE-FINISHED METAL LINER PANEL.

COLOR: .

• PRE-FINISHED METAL GUTTER.

COLOR: .

• PRE-FINISHED METAL DOWNSPOUT.

COLOR: .

• PRE-FINISHED METAL RIDGE TRIM.

COLOR: .

• PRE-FINISHED METAL EAVE TRIM.

COLOR: .

• PRE-FINISHED METAL RAKE TRIM.

COLOR: .

• PRE-FINISHED METAL OUTSIDE CORNER TRIM.

COLOR: .

• PRE-FINISHED METAL INSIDE CORNER TRIM.

COLOR: .

• PRE-FINISHED METAL BASE TRIM.

COLOR: .

• PRE-FINISHED METAL FRAMED OPENING TRIM.

COLOR: .

• PAINTED HOLLOW METAL WINDOW FRAME.

COLOR: .

• EXTERIOR INSULATION FINISH SYSTEM (EIFS).

COLOR: .

• PRE-FINISHED METAL LOUVER.

COLOR: .

• PAINTED HOLLOW METAL DOOR.

COLOR: .

• PAINTED HOLLOW METAL DOOR FRAME.

COLOR: .

• PAINTED STEEL BOLLARD.

COLOR: PANTONE PQ137C - SAFETY YELLOW

• PAINTED EXPOSED CONCRETE

COLOR: .

• PAINTED EXTERIOR RAILING.

COLOR: PANTONE PQ137C - SAFETY YELLOW

• GLAZING.

LIGHT GRAY EXTERIOR PANE.

CLEAR INTERIOR PANE.

GENERAL NOTES

1. THESE DRAWINGS ARE NOT TO BE SCALED. REFER TO DIMENSIONS

INDICATED ON DIMENSION PLANS, SHOP DRAWINGS, OR ESTABLISHED

FIELD DIMENSIONS. WHERE NO DIMENSIONS OR METHOD OF

DETERMINING A LOCATION IS GIVEN, VERIFY WITH ARCHITECT PRIOR TO

PROCEEDING.

2. VERIFY EQUIPMENT REQUIREMENTS FOR ROUGH-IN AND UTILITY

CONNECTIONS PRIOR TO CONSTRUCTION TO ASSURE THAT PROPER

BLOCKING, OPENINGS, AND UTILITY CONNECTIONS ARE PROVIDED.

3. IN ALL CONTINUOUS, UNINTERRUPTED GYPSUM BOARD CEILINGS,

PROVIDE CONTROL JOINTS AT INTERVALS SPECIFIED (BUT NOT GREATER

THAN 30 FEET). VERIFY LOCATIONS WITH ARCHITECT PRIOR TO

PROCEEDING.

4. PROVIDE PROPER SEPARATION BETWEEN ALL DISSIMILAR MATERIALS.

5. EQUIPMENT SHOWN IN DRAWINGS IS FOR LAYOUT AND COORDINATION

PURPOSES.

6. FURNITURE IS SHOWN IN THE DRAWINGS IS FOR LAYOUT AND

COORDINATION PURPOSES.

7. PROVIDE ABOVE CEILING STRUCTURAL SUPPORT FOR ALL CEILING

MOUNTED EQUIPMENT.

8. DIMENSIONS IN PLANS ARE TYPICALLY SHOWN TO:

A. COLUMN CENTERLINES.

B. FACE OF UNIT MASONRY OR CONCRETE.

C. FACE OF FRAMING WALLS.

D. FACE OF INTERIOR PARTITIONS (FACE OF CMU,

IMP, MTL PANEL, STUD)

NOTE: WALL WITH APPLIED FINISHES ARE DIMENSIONED TO

REFERENCES ABOVE U.O.N.

9. DIMENSIONS IN ELEVATIONS/ SECTIONS ARE TYPICALLY SHOWN TO:

A. TOP OF STEEL

B. TOP OF TILT-UP/ CAST-IN-PLACE CONCRETE, UNIT MASONRY.

C. FLOOR SLAB/ LEVEL FLOOR.

D. APPROXIMATE ROOF FINISHED ELEVATION

KEYED PLAN

FIRST FLOOR

100' - 0"

FIRST FLOOR

100' - 0"

WAINSCOT

103' - 4"

WAINSCOT

103' - 4"

TOP OF TILT-UP WALL

113' - 4"

TOP OF TILT-UP WALL

113' - 4"

3 2

101-A 105-A 115-F 115-E 115-D W1 W1 W1

114 114 114

115 113 120 120 120116

104 104

FIRST FLOOR

100' - 0"

FIRST FLOOR

100' - 0"

WAINSCOT

103' - 4"

WAINSCOT

103' - 4"

TOP OF TILT-UP WALL

113' - 4"

TOP OF TILT-UP WALL

113' - 4"

AD BC

115-C119

104104

112112

111 111

FIRST FLOOR

100' - 0"

FIRST FLOOR

100' - 0"

WAINSCOT

103' - 4"

WAINSCOT

103' - 4"

TOP OF TILT-UP WALL

113' - 4"

TOP OF TILT-UP WALL

113' - 4"

A DB C

W1 W1 W1 W1 W1 W1

119119

104 104

103 103

112 112

112 112

114114 114 114 114114

119 119

121121

111111

FIRST FLOOR

100' - 0"

FIRST FLOOR

100' - 0"

WAINSCOT

103' - 4"

WAINSCOT

103' - 4"

TOP OF TILT-UP WALL

113' - 4"

TOP OF TILT-UP WALL

113' - 4"

115-B 115-A 104-A W1 W1 W1

120 115

114 114 114

104 104

KEYED NOTES

101 PRE-FINISHED METAL ROOF PANEL.

102 PRE-FINISHED METAL FASCIA TRIM

103 PRE-FINISHED METAL OPEN FACED DOWNSPOUT.

104 PRE-FINISHED METAL GUTTER.

111 PRE-FINISHED METAL CAP TRIM.

112 PRE-FINISHED METAL RIDGE TRIM.

113 ATFP COMPLIANT INSULATED HOLLOW METAL DOOR AND FRAME.

114 ATFP COMPLIANT FIXED ALUMINUM WINDOW.

115 ATFP COMPLIANT ALUMINUM STOREFRONT SYSTEM.

116 MASONRY VENEER.

119 PRE-CAST CONCRETE SPLASHBLOCK.

120 BALLISTIC RATED INSULATED HOLLOW METAL DOOR AND FRAME.

121 EXTERIOR INSULATION FINISH SYSTEM (EIFS).

KEYED NOTES ARE REFERENCED BY ELEVATION SHEETS.

SHEET ID

D E

S

IG

N B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

J R

P L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A

T E

R R

E H

A U

T E

, I N

D

IA

N A

IN

ID

IA

N

A A

IR

N

A T

IO

N

A L

G U

A R

D A

N G

S M

A

LL

A R

M S

R A

N G

E C

O N

T R

A C

T

P

2#

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

US Army Corps of Engineers ®

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

S

IZ

E

A N

S I D

P R E

LIM

IN

A R Y

N O

T F

N S

TR

U C

TIO

N

14000 QUAIL SPRINGS PARKWAY

SUITE 500

OKLAHOMA CITY, OK 73134

T: 405-478-5353

P R

O J E

C T

N O

A-201

M N

O B

E R

T

M N

O B

E R

T

C B

U N

A L

D M

O T

L E

Y

B U

IL

D

IN

G

E

LE

V A

T

IO

N S

A R

C H

IT

E

C T

U R

A L

CERTIFIED FINAL SUBMITTAL - DESIGN BUILD RFP

3/32" = 1'-0"1

BUILDING ELEVATION - NORTH

3/32" = 1'-0"4

BUILDING ELEVATION - WEST

3/32" = 1'-0"3

BUILDING ELEVATION - EAST

3/32" = 1'-0"2

BUILDING ELEVATION - SOUTH

N

MCSATS CATM

KEY PLAN

SCALE IN FEET - 3/32" = 1'-0"

8' 4' 0' 8' 24'16'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

A

M E

N D

M E

N T

W

2Q R

-2

7A _C

ER

TF

in al

_P la ns -0

DOOR SCHEDULE NOTES

1. INSULATED DOOR AND FRAME.

2. INSULATED COILING OVERHEAD DOOR.

3. EXIT ONLY DOOR.

4. BUILDING ACCESS CONTROLS.

DOOR SCHEDULE ABBREVIATIONS

INTR INTERIOR

EXTR EXTERIOR

SG SINGLE DOOR

DA DOUBLE ACTING

DD DOUBLE DOOR

DE DOUBLE EGRESS

SL SLIDER

OH OVERHEAD DOOR

IM INSULATED METAL

HM HOLLOW METAL

WD WOOD

AL ALUMINUM

STL STEEL

FL FLUSH

NV NARROW VIEW

HV HALF VIEW

FV FULL VIEW

PV PORTAL VIEW

SS STAINLESS STEEL

SSL SINGLE SIDE LITE

DS DOUBLE SIDE LITE

NVC NARROW VIEW CENTERED

LO LOUVER

GLAZING SCHEDULE

G1 1" INSULATED GLAZING

G2 1/4" CLEAR TEMPERED GLAZING.

G3 BALLISTIC RATED.

G4 CERTIFIED BLAST RESISTANT 1" INSULATED GLAZING UNIT. GLASS TO BE

1/4" NOMINAL LAMINTED GLASS CONSISTING OF TWO 1/8" NOMINAL

GLASS PANES BONDED TOGETHER WITH A MINIMUM OF A 0.030"

INTERLAYER OF A MATERIAL DESIGN FOR BLAST RESISTANCE. THE

GLAZING FRAME BIT SHALL BE IN ACCORDANCE WITH ASTM 2248.

DOOR SCHEDULE NOMENCLATURE

FLUSH DOOR (DESIGN F)

THE TERM “FLUSH,” WHEN USED TO DESCRIBE A DOOR TYPE, REFERS TO A

DOOR WITHOUT LITES OR LOUVERS.

FULL FLUSH DOOR

FEATURES NO VISIBLE SEAMS ON THE SURFACE OF THE FACES. FULL HEIGHT

VERTICAL SEAMS ARE VISIBLE ON DOOR EDGES.

SEAMLESS DOOR

FEATURES NO VISIBLE SEAMS EITHER ON THE FACE OR ALONG THE VERTICAL

EDGES OF THE DOOR.

STILE AND RAIL OR STILE AND PANEL DOOR

STILE AND RAIL ARE EITHER MITERED OR BUTTED. MITERED JOINTS ARE

WELDED AND GROUND SMOOTH, SUCH THAT NO MITER JOINTS APPEAR ON THE

DOOR FACES. BUTTED JOINT SEAMS SHALL REMAIN VISIBLE. THE PANELS ARE

INTERLOCKED WITH STILES AND RAILS AND THEY MAY BE FLUSH OR RECESSED

WITH PERIMETER SURFACES.

HALF GLASS DOORS (DESIGN G)

THE SIZE AND LOCATION FROM THE FINISHED FLOOR TO THE GLAZED OPENING

WILL VARY WITH THE MANUFACTURER. THEIR LITERATURE SHOULD BE

CONSULTED TO DETERMINE THIS INFORMATION AS WELL AS RECOMMENDED

GLASS SIZES. MULTIPLE LITE PATTERNS ARE CREATED BY THE INSTALLATION

OF MUNTINS.

DOORS WITH LITES ARE DESIGNED TO ACCEPT GLAZING MATERIAL OF VARIOUS

THICKNESSES.

IN ACCORDANCE WITH THE ARCHITECTURAL BARRIERS ACT (ABA), DOORS

CONTAINING ONE OR MORE GLAZING PANELS SHALL HAVE THE BOTTOM OF AT

LEAST ONE GLASS PANEL A MAXIMUM OF 43" FROM THE FINISHED FLOOR.

FULL GLASS DOORS (DESIGN FG)

A MAXIMUM 7" RAIL AND STILE OCCUR AT THE TOP AND AT THE VERTICAL EDGES

OF THIS DOOR. AN 8" MINIMUM RAIL OCCURS AT THE BOTTOM.

TO COMPLY WITH THE ARCHITECTURAL BARRIERS ACT (ABA), THE BOTTOM RAIL

SHALL BE SPECIFIED AS MINIMUM 10” MEASURED VERTICALLY FROM THE FLOOR

AND SHALL BE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL

WIDTH OF THE DOOR. MUNTINS ARE NORMALLY USED TO CREATE THE

MULTIPLE LITE FG3 UNIT, ALTHOUGH A 5"-5 1/2" WELDED-IN RAIL IS STANDARD

WITH SOME DOOR MANUFACTURERS. CONSULT INDIVIDUAL MANUFACTURER’S

LITERATURE FOR THEIR DESIGN VARIATIONS.

NARROW LITE DOOR (DESIGN N)

THE GLASS CUTOUT IN THESE DOORS OCCURS NEAR THE LOCK STILE. THE

WIDTH OF THE LITE SHALL BE A MINIMUM OF 3" AND THE HEIGHT VARIES

BETWEEN 10" AND 60". CONSULT THE INDIVIDUAL MANUFACTURER’S

LITERATURE FOR THE NARROW LITE STANDARD SPECIFICATION IN THEIR

PROGRAM.

VISION LITE DOOR (DESIGN V)

THE INDUSTRY STANDARD IS A 10" X 10" LITE ON THE VERTICAL CENTERLINE OF

THE DOOR. THE HORIZONTAL CENTERLINE OF THE LITE WILL VARY FROM 60" TO

66" FROM THE FINISHED FLOOR. CONSULT THE INDIVIDUAL MANUFACTURER’S

LITERATURE FOR DETAILS. THE “V” DOOR DOES NOT COMPLY WITH THE

ARCHITECTURAL BARRIERS ACT (ABA). TO SATISFY THIS REQUIREMENT A

NARROW LITE (N) SHALL BE USED.

LOUVERED DOOR (DESIGN L)

AS INDICATED BY THE ASTERISK NOTE, THERE ARE A NUMBER OF LOUVERS AND

GRILLES AVAILABLE. THE CHOICE OF WHICH ONE TO USE MUST BE DETERMINED

BY THE ARCHITECT ON AESTHETIC, FUNCTIONAL AND ECONOMIC GROUNDS AS

WELL AS FIRE PROTECTION.

A LOUVER IS AN OPENING IN THE DOOR WITH A SERIES OF SLATS OR BLADES TO

ALLOW PASSAGE OF AIR. GENERALLY, LOUVERS ARE PREFABRICATED BY

WELDING OR TENONING THE BLADES TO THE MOULDING FRAME. THIS LOUVER

FRAME IS INSERTED INTO THE OPENING IN THE DOOR PREPARE TO RECEIVE

THE LOUVER. FUSIBLE LINK LOUVERS ARE USED TO CONTROL PASSAGE OF

FLAMES AND HEAT. THESE ARE INSERTED INTO FIRE RATED DOORS. CONSULT

INDIVIDUAL MANUFACTURER’S LITERATURE FOR DETAILS.

DUTCH DOOR (DESIGN D)

UNLESS SPECIFIED OTHERWISE, THE DUTCH DOOR IS FURNISHED WITHOUT A

SHELF. THIS ACCESSORY IS AVAILABLE, HOWEVER, FROM ALL

MANUFACTURERS. THE SHELF HEIGHT MAY VARY FROM 36" TO 42" FROM THE

FINISHED FLOOR. CONSULT THE INDIVIDUAL MANUFACTURER’S LITERATURE IF

THIS IS CRITICAL.

TO COMPLY WITH THE ARCHITECTURAL BARRIERS ACT (ABA), THE SHELF

HEIGHT SHALL BE 36" MAXIMUM FROM THE FINISHED FLOOR.

COORDINATE WITH

WIDTH OF DOOR

C O

O R

D

IN

A T

E W

IT

H

H

IE

G H

T O

F D

O O

R

2" H

E A

D A

N D

JA

M

B

F1

DOOR FRAME TYPES

COORDINATE WITH

WIDTH OF DOOR

C O

O R

D

IN

A T

E W

IT

H

H

IE

G H

T O

F D

O O

R

2" H

E A

D A

N D

JA

M

B

F2

COORDINATE WITH

WIDTH OF DOOR

C O

O R

D

IN

A T

E W

IT

H

H

IE

G H

T O

F D

O O

R

4" H

E A

D A

N D

JA

M

B

F3

COORDINATE WITH

WIDTH OF DOOR

C O

O R

D

IN

A T

E W

IT

H

H

IE

G H

T O

F D

O O

R

4" H

E A

D A

N D

JA

M

B

F4

COORDINATE WITH

WIDTH OF DOOR

C O

O R

D

IN

A T

E W

IT

H

H

IE

G H

T O

F D

O O

R

2" H

E A

D A

N D

JA

M

B

F5

G4

8'

4' - 8"

D1

DOOR TYPES

D2 D3 D4 D5 D6 D7 D8

DESIGN F DESIGN F DESIGN N DESIGN N DESIGN G DESIGN G DESIGN FG DESIGN FG

WINDOW TYPES

W1

4' - 0"

G4

2" H

E A

D

JA

M

B

S

IL

L

W2

4' - 0"

G3

2" H

E A

D

JA

M

B

S

IL

L 4'

2'

W3

17' - 0"

G3

2" H

E A

D

JA

M

B

S

IL

L 4'

W4

1' - 10"

G3

2" H

E A

D

JA

M

B

S

IL

L 4'

8'

8'

8'

8'

GENERAL NOTES

1. THESE DRAWINGS ARE NOT TO BE SCALED. REFER TO DIMENSIONS

INDICATED ON DIMENSION PLANS, SHOP DRAWINGS, OR ESTABLISHED

FIELD DIMENSIONS. WHERE NO DIMENSIONS OR METHOD OF

DETERMINING A LOCATION IS GIVEN, VERIFY WITH ARCHITECT PRIOR TO

PROCEEDING.

2. VERIFY EQUIPMENT REQUIREMENTS FOR ROUGH-IN AND UTILITY

CONNECTIONS PRIOR TO CONSTRUCTION TO ASSURE THAT PROPER

BLOCKING, OPENINGS, AND UTILITY CONNECTIONS ARE PROVIDED.

3. IN ALL CONTINUOUS, UNINTERRUPTED GYPSUM BOARD CEILINGS,

PROVIDE CONTROL JOINTS AT INTERVALS SPECIFIED (BUT NOT GREATER

THAN 30 FEET). VERIFY LOCATIONS WITH ARCHITECT PRIOR TO

PROCEEDING.

4. PROVIDE PROPER SEPARATION BETWEEN ALL DISSIMILAR MATERIALS.

5. EQUIPMENT SHOWN IN DRAWINGS IS FOR LAYOUT AND COORDINATION

PURPOSES.

6. FURNITURE IS SHOWN IN THE DRAWINGS IS FOR LAYOUT AND

COORDINATION PURPOSES.

7. PROVIDE ABOVE CEILING STRUCTURAL SUPPORT FOR ALL CEILING

MOUNTED EQUIPMENT.

8. DIMENSIONS IN PLANS ARE TYPICALLY SHOWN TO:

A. COLUMN CENTERLINES.

B. FACE OF UNIT MASONRY OR CONCRETE.

C. FACE OF FRAMING WALLS.

D. FACE OF INTERIOR PARTITIONS (FACE OF CMU,

IMP, MTL PANEL, STUD)

NOTE: WALL WITH APPLIED FINISHES ARE DIMENSIONED TO

REFERENCES ABOVE U.O.N.

9. DIMENSIONS IN ELEVATIONS/ SECTIONS ARE TYPICALLY SHOWN TO:

A. TOP OF STEEL

B. TOP OF TILT-UP/ CAST-IN-PLACE CONCRETE, UNIT MASONRY.

C. FLOOR SLAB/ LEVEL FLOOR.

D. APPROXIMATE ROOF FINISHED ELEVATION

SHEET ID

D E

S

IG

N B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

J R

P L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A

T E

R R

E H

A U

T E

, I N

D

IA

N A

IN

ID

IA

N

A A

IR

N

A T

IO

N

A L

G U

A R

D A

N G

S M

A

LL

A R

M S

R A

N G

E C

O N

T R

A C

T

P

2#

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

US Army Corps of Engineers ®

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

S

IZ

E

A N

S I D

P R E

LIM

IN

A R Y

N O

T F

N S

TR

U C

TIO

N

14000 QUAIL SPRINGS PARKWAY

SUITE 500

OKLAHOMA CITY, OK 73134

T: 405-478-5353

P R

O J E

C T

N O

A-610

M N

O B

E R

T

M N

O B

E R

T

C B

U N

A L

D M

O T

L E

Y

D O

O R

S C

H E

D U

L E

A R

C H

IT

E

C T

U R

A L

CERTIFIED FINAL SUBMITTAL - DESIGN BUILD RFP

DOOR SCHEDULE - FIRST FLOOR

DOOR

NUMBER

DOOR FRAME

STC RATING FIRE RATING HARDWARE

DETAILS

NOTESTYPE WIDTH HEIGHT THICKNESS GLAZING MATERIAL TYPE MATERIAL HEAD JAMB THRESHOLD

101-A D7 3' - 0" 6' - 10" 1 3/4" AL F5 AL 4

101-B D7 3' - 0" 6' - 10" 1 3/4" AL F5 AL

104-A D7 3' - 0" 6' - 10" 1 3/4" AL F5 AL 4

104-B D7 3' - 0" 6' - 10" 1 3/4" AL F5 AL

105-A D2 6' - 0" 7' - 0" 1 3/4" HM F4 HM 1, 4

106-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 4

106-B D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 90 4

107-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 90 4

108-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 4

108-B D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 90 4

109-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 4

110-A D3 3' - 0" 7' - 0" 1 3/4" HM F3 HM 4

111-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM

112-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM

113-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM

114-A D3 3' - 0" 7' - 0" 1 3/4" HM F3 HM

115-A D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 1, 3

115-B D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 1, 3

115-C D2 6' - 0" 7' - 0" 1 3/4" HM F4 HM 1

115-D D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 1, 4

115-E D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 1, 3

115-F D1 3' - 0" 7' - 0" 1 3/4" HM F3 HM 1, 3

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

A

M E

N D

M E

N T

W

2Q R

-2

7A _C

ER

TF

in al

_P la ns -0

A A

D D

B B

C C

A-201

A-201

A-201

A-201

11' - 0"

9' - 0"

9' - 0"

9' - 0"

11' - 0"

11' - 0"

9' - 0"

9' - 0" 9' - 0"

9' - 0"

9' - 0"

9' - 0"

EXPOSED

107108 106

108106

107107107107

107107107107

9' - 0"

BULLET TRAP

ARMS RANGE

CLASSROOM

ENTRY VESTIBULE

MECHANICAL

CORRIDOR

WEAPONS MX AND

CLEANING

ENTRY VESTIBULE

RANGE STORAGE

ACP VESTIBULE

RSO

ACP VESTIBULE

TOILET

TOILET WITH

SHOWER

JANITOR

CORRIDOR

108106

108106

11' - 0"

9' - 0"

9' - 0"

101101101101101101101101101

OPEN TO

STRUCTURE ABOVE

GENERAL NOTES

1. THESE DRAWINGS ARE NOT TO BE SCALED. REFER TO DIMENSIONS

INDICATED ON DIMENSION PLANS, SHOP DRAWINGS, OR ESTABLISHED

FIELD DIMENSIONS. WHERE NO DIMENSIONS OR METHOD OF

DETERMINING A LOCATION IS GIVEN, VERIFY WITH ARCHITECT PRIOR TO

PROCEEDING.

2. VERIFY EQUIPMENT REQUIREMENTS FOR ROUGH-IN AND UTILITY

CONNECTIONS PRIOR TO CONSTRUCTION TO ASSURE THAT PROPER

BLOCKING, OPENINGS, AND UTILITY CONNECTIONS ARE PROVIDED.

3. IN ALL CONTINUOUS, UNINTERRUPTED GYPSUM BOARD CEILINGS,

PROVIDE CONTROL JOINTS AT INTERVALS SPECIFIED (BUT NOT GREATER

THAN 30 FEET). VERIFY LOCATIONS WITH ARCHITECT PRIOR TO

PROCEEDING.

4. PROVIDE PROPER SEPARATION BETWEEN ALL DISSIMILAR MATERIALS.

5. EQUIPMENT SHOWN IN DRAWINGS IS FOR LAYOUT AND COORDINATION

PURPOSES.

6. FURNITURE IS SHOWN IN THE DRAWINGS IS FOR LAYOUT AND

COORDINATION PURPOSES.

7. PROVIDE ABOVE CEILING STRUCTURAL SUPPORT FOR ALL CEILING

MOUNTED EQUIPMENT.

8. DIMENSIONS IN PLANS ARE TYPICALLY SHOWN TO:

A. COLUMN CENTERLINES.

B. FACE OF UNIT MASONRY OR CONCRETE.

C. FACE OF FRAMING WALLS.

D. FACE OF INTERIOR PARTITIONS (FACE OF CMU,

IMP, MTL PANEL, STUD)

NOTE: WALL WITH APPLIED FINISHES ARE DIMENSIONED TO

REFERENCES ABOVE U.O.N.

9. DIMENSIONS IN ELEVATIONS/ SECTIONS ARE TYPICALLY SHOWN TO:

A. TOP OF STEEL

B. TOP OF TILT-UP/ CAST-IN-PLACE CONCRETE, UNIT MASONRY.

C. FLOOR SLAB/ LEVEL FLOOR.

D. APPROXIMATE ROOF FINISHED ELEVATION

KEYED PLAN

KEYED NOTES

KEYED NOTES ARE REFERENCED BY THIS SHEET.

101 CONTINUOUS SUSPENDED SAWTOOTH BALLISTIC BAFFLE CEILING

SYSTEM.

102 SLOPED SUSPENDED ACOUSTICAL CEILING.

103 SUSPENDED ACOUSTICAL CEILING.

104 TARGET RETRIEVER.

105 CONTINUOUS SUSPENDED BALLISTIC CEILING.

106 PRE-FINISHED METAL SOFFIT PANEL.

107 PRE-FINISHED METAL OPEN FACED DOWNSPOUT.

108 PRE-FINISHED METAL GUTTER.

SHEET ID

D E

S

IG

N B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

J R

P L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A

T E

R R

E H

A U

T E

, I N

D

IA

N A

IN

ID

IA

N

A A

IR

N

A T

IO

N

A L

G U

A R

D A

N G

S M

A

LL

A R

M S

R A

N G

E C

O N

T R

A C

T

P

2#

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

US Army Corps of Engineers ®

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

S

IZ

E

A N

S I D

P R E

LIM

IN

A R Y

N O

T F

N S

TR

U C

TIO

N

14000 QUAIL SPRINGS PARKWAY

SUITE 500

OKLAHOMA CITY, OK 73134

T: 405-478-5353

P R

O J E

C T

N O

A-710

M N

O B

E R

T

M N

O B

E R

T

C B

U N

A L

D M

O T

L E

Y

F

IR

S T

F L

O O

R R

E F

LE

C

T E

D C

E

IL

IN

G

P

LA

N

A R

C H

IT

E

C T

U R

A L

CERTIFIED FINAL SUBMITTAL - DESIGN BUILD RFP

3/32" = 1'-0"1

FIRST FLOOR REFLECTED CEILING PLAN

N

MCSATS CATM

KEY PLAN

SCALE IN FEET - 3/32" = 1'-0"

8' 4' 0' 8' 24'16'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

A

M E

N D

M E

N T

W

2Q R

-2

7A _C

ER

TF

in al

_P la ns -0

ARMS RANGE

MECHANICAL YARD

MECHANICAL YARD

MECHANICAL YARD

I-

I-

BULLET TRAP

NO FURNITURE THIS SECTOR

E1

A

E2

C

C

C

C C C

E1 E1

E2E2

E2

E2

E2

E1

E2

C

GENERAL NOTES

1. REFER TO I-601 FOR FINISH ABBREVIATIONS AND

SPECIFICATIONS.

2. SOME MATERIALS AND/OR FINISHES MAY NOT APPEAR ON

THIS SHEET. REFER TO INTERIOR ROOM FINISH SCHEDULE

ON I-601, FOR FINISH INFORMATION.

3. FURNITURE LAYOUT IS BEING SHOWN FOR COORDINATION

PURPOSES ONLY AND WILL BE A BID OPTION TO THE

CONTRACT.

4. PROVIDE MANUAL WINDOW SHADES WHERE MARKED WITH

KEYED NOTE #1 ON PLANS.

INTERIOR FINISH KEYED NOTES AND CODES

WS-1: WINDOW SHADES (MANUAL) - REFER TO ARCHITECTURAL

DETAILS FOR MORE INFORMATION.

LK-1: (13) DOUBLE-TIER LOCKERS, 78"H

RAF (RAISED ACCESS FLOORING) - REFER TO ARCHITECTURAL

PLANS FOR MORE INFORMATION.

SWC-1: SHOWER CURTAIN

SIGNAGE LEGEND

KEYED NOTE INDICATES SIGN TYPE

SIGN TYPES

A ROOM IDENTIFICATION SIGN

C EXIT PLAQUE

D1 ALL GENDER PUBLIC SERVICE TOILET, ADA SIGN

D2 UNISEX TOILET & SHOWER SIGN

E1 EXTERIOR REGULATORY NO SMOKING SIGN

E2 EXTERIOR ROOM IDENTIFICATION SIGN

X

SHEET ID

D E

S

IG

N B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

J R

P L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A

T E

R R

E H

A U

T E

, I N

D

IA

N A

IN

ID

IA

N

A A

IR

N

A T

IO

N

A L

G U

A R

D A

N G

S M

A

LL

A R

M S

R A

N G

E C

O N

T R

A C

T

P

2#

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

US Army Corps of Engineers ®

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

S

IZ

E

A N

S I D

P R E

LIM

IN

A R Y

N O

T F

N S

TR

U C

TIO

N

14000 QUAIL SPRINGS PARKWAY

SUITE 500

OKLAHOMA CITY, OK 73134

T: 405-478-5353

P R

O J E

C T

N O

I-111

A

S C

H L E

P P

K

H A

Y E

S

K

H A

Y E

S

D

M O

T L E

Y

F

IR

S T

F L

O O

R F

IN

IS

H P

LA

N

S

E C

T O

R

IN

T

E R

IO

R

S

CERTIFIED FINAL SUBMITTAL - DESIGN BUILD RFP

N

MCSATS CATM

KEY PLAN

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

1/8" = 1'-0"1

FIRST FLOOR FINISH PLAN - SECTOR 1

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

A

M E

N D

M E

N T

(BID OPTION)

W

2Q R

-2

7A _C

ER

TF

in al

_P la ns -0

CLASSROOM

ENTRY VESTIBULE

MECHANICAL

ACP VESTIBULE

CORRIDOR

RSO

ACP VESTIBULE

RANGE STORAGE

ENTRY VESTIBULE

WEAPONS MX AND

CLEANING

CORRIDOR

TOILET

TOILET WITH

SHOWER

JANITOR

I-

I-

T1 T1 T1 T1 T1

T1 T1 T1 T1 T1

T1 T1 T1 T1 T1

C1

QTY:15

G1

G1

G1

M1

M1

A

C

C

A

A

D1 D2 A

A

A

A

1 1 1

M2

M2

M2

M3

M3

C

E1

E1

E2

C

E1

E1

GENERAL NOTES

1. REFER TO I-601 FOR FINISH ABBREVIATIONS AND

SPECIFICATIONS.

2. SOME MATERIALS AND/OR FINISHES MAY NOT APPEAR ON

THIS SHEET. REFER TO INTERIOR ROOM FINISH SCHEDULE

ON I-601, FOR FINISH INFORMATION.

3. FURNITURE LAYOUT IS BEING SHOWN FOR COORDINATION

PURPOSES ONLY AND WILL BE A BID OPTION TO THE

CONTRACT.

4. PROVIDE MANUAL WINDOW SHADES WHERE MARKED WITH

KEYED NOTE #1 ON PLANS.

INTERIOR FINISH KEYED NOTES AND CODES

WS-1: WINDOW SHADES (MANUAL) - REFER TO ARCHITECTURAL

DETAILS FOR MORE INFORMATION.

LK-1: (13) DOUBLE-TIER LOCKERS, 78"H

RAF (RAISED ACCESS FLOORING) - REFER TO ARCHITECTURAL

PLANS FOR MORE INFORMATION.

SWC-1: SHOWER CURTAIN

SIGNAGE LEGEND

KEYED NOTE INDICATES SIGN TYPE

SIGN TYPES

A ROOM IDENTIFICATION SIGN

C EXIT PLAQUE

D1 ALL GENDER PUBLIC SERVICE TOILET, ADA SIGN

D2 UNISEX TOILET & SHOWER SIGN

E1 EXTERIOR REGULATORY NO SMOKING SIGN

E2 EXTERIOR ROOM IDENTIFICATION SIGN

X

SHEET ID

D E

S

IG

N B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

J R

P L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

A

T E

R R

E H

A U

T E

, I N

D

IA

N A

IN

ID

IA

N

A A

IR

N

A T

IO

N

A L

G U

A R

D A

N G

S M

A

LL

A R

M S

R A

N G

E C

O N

T R

A C

T

P

2#

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

B

C

D

E

F

G

H

J

K

L

M

N

P

US Army Corps of Engineers ®

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

S

IZ

E

A N

S I D

P R E

LIM

IN

A R Y

N O

T F

N S

TR

U C

TIO

N

14000 QUAIL SPRINGS PARKWAY

SUITE 500

OKLAHOMA CITY, OK 73134

T: 405-478-5353

P R

O J E

C T

N O

I-112

A

S C

H L E

P P

K

H A

Y E

S

K

H A

Y E

S

D

M O

T L E

Y

F

IR

S T

F L

O O

R F

IN

IS

H P

LA

N

S

E C

T O

R

IN

T

E R

IO

R

S

CERTIFIED FINAL SUBMITTAL - DESIGN BUILD RFP

SCALE IN FEET - 1/8" = 1'-0"

8' 4' 0' 8' 24'16'

N

MCSATS CATM

KEY PLAN

1/8" = 1'-0"1

FIRST FLOOR FINISH PLAN - SECTOR 2

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

A

M E

N D

M E

N T

FURNITURE SCHEDULE

CODE DESCRIPTION COUNT

C1 TRAINING CHAIR 15

G1 STORAGE SHELVING - 24"D X 36"W X

78"H

M1 TACK BOARD 2

M2 TRASH RECEPTACLE - 23 GAL. 3

M3 ENTRY MAT, 4' X 6' 2

T1 TABLE - 24" X 42" 151

(BID OPTION)

W

2Q R

-2

7A _C

ER

TF

in al

_P la ns -0

Att .1 Conceptual Drawings LANE 10
Attachment 1.1 - A-201 BUILDING ELEVATIONS – 10 LANE_AMD03.pdf
A-201 - BUILDING ELEVATIONS
Attachment 1.1 - A-610 DOOR SCHEDULE – 10 LANE_AMD03.pdf
A-610 - DOOR SCHEDULE
Attachment 1.1 - A-710 FIRST FLOOR REFLECTED CEILING PLAN – 10 LANE_AMD03.pdf
A-710 - FIRST FLOOR REFLECTED CEILING PLAN
Attachment 1.1 - I-111 FIRST FLOOR FINISH PLAN SECTOR 1 – 10 LANE_AMD03.pdf
I-111 - FIRST FLOOR FINISH PLAN - SECTOR 1
Attachment 1.1 - I-112 FIRST FLOOR FINISH PLAN SECTOR 2 – 10 LANE_AMD03.pdf
I-112 - FIRST FLOOR FINISH PLAN - SECTOR 2
Att 1.2 Conceptual Drawings LANE 14
Attachment 1.2 - A-201 BUILDING ELEVATIONS – 14 LANE_AMD03.pdf
A-201 - BUILDING ELEVATIONS
Attachment 1.2 - A-610 DOOR SCHEDULE – 14 LANE_AMD03.pdf
A-610 - DOOR SCHEDULE
Attachment 1.2 - A-710 FIRST FLOOR REFLECTED CEILING PLAN – 14 LANE_AMD03.pdf
Sheets
A-710 - FIRST FLOOR REFLECTED CEILING PLAN
Attachment 1.2 - I-111 FIRST FLOOR FINISH PLAN SECTOR 1 – 14 LANE_AMD03.pdf
I-111 - FIRST FLOOR FINISH PLAN - SECTOR 1
Attachment 1.2 - I-112 FIRST FLOOR FINISH PLAN SECTOR 2 – 14 LANE_AMD03.pdf
I-112 - FIRST FLOOR FINISH PLAN - SECTOR 2

File details come from the government source that posted it. Updated .