W912QR21R0058_Plans-0002.pdf

PDF 2 MB Posted

Attached to
Hypersonics Lab Renovation at Wright-Patterson Air Force Base, OH
Solicitation number
W912QR21R0058
Issued by

About this file

This solicitation is for a Hypersonics Lab Renovation project at Wright-Patterson Air Force Base in Ohio with an estimated construction cost between $1 million to $5 million. The project involves renovating Building 655 including interior renovations and systems work. A site visit is scheduled for July 8, 2021 with an RSVP deadline of July 2. This is a full and open procurement requiring compliance with System for Award Management (SAM) and Central Contractor Registration (CCR) requirements. The North American Industry Classification System (NAICS) code is 236220 with a size standard of $39.5 million.

View the file

Other files

File Type Posted
W912QR21R0058-0005.pdf PDF
W912QR21R0058-0004.pdf PDF
W912QR21R0058-0003.pdf PDF
W912QR21R0058_Specs-0002.pdf PDF
Hypersonics Site Visit Roster.pdf PDF
W912QR21R0058-0001.pdf PDF
W912QR21R0058 - Hypersonics Lab Renovation.pdf PDF
W912QR21R0058_Plans-0000.pdf PDF
W912QR21R0058_SID-0000.pdf PDF
W912QR21R0058_FFE-0000.pdf PDF
W912QR21R0058_Specs-0000.pdf PDF
JA (redacted) Simplex.pdf PDF
JA (redacted) Siemens Talon - Hypersonics.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T ectonic Cop yright 2007

B363529D363529 D363529 T489029MD303524

W304818 W364818

PAINTED

CONCRETE

COLUMN

TORCH

TEST

STATION

EXISTING

UTILITY CHASE

REPAIRED AND

REPAINTED

PAINTED CONCRETE

COLUMN

CHEMICAL RESISTANT RESIN

COUNTERTOP AND SPLASH

D483518

B303529 D303529

FUME HOOD END FACE

CHEMICAL RESISTANT

RESIN COUNTERTOP

VERTICAL UTILITY CHASE

BY CABINET MANUFACTURER

B303529

B303529 MD423529 B303529 D483529 B303529

(3) W364818 WITH SLOPED TOP

COVER PANELS

STAINLESS STEEL

COUNTERTOPS AND SPLASH

KNEE SPACE

(2) W364818 WITH SLOPED TOP

COVER PANELS

B303529 D483529 D483529 B303529

D483518

DC399024

EXIST FEC

TO REMAIN

FULL GLASS DOOR

WITH FIRE RATED

GLAZING

EMERGENCY EYE WASH

AND SHOWER

STORAGE LOCKER

PAINTED ROUND

CONCRETE

COLUMN

PAINTED ROUND

CONCRETE

COLUMN

TORCH TEST STATION

D483529

W303618 W243618 W484818

SB483529D483529 B483529 B483529

W243618

D483529 B483529

W364818

CHEMICAL RESISTANT

RESIN COUNTERTOP

AND SPLASH

EXISTING ROUND

COLUMN - PATCH AND

PAINT TO MATCH WALLS

TOOTH IN NEW BULLNOSE

CMU. APPLY BLOCK FILLER ON

NEW CMU PRIOR TO PAINTING

EXISTING WALK-IN

FUME HOOD

B303529

INDICATES TYPE CABINET (B BASE, SB

SINK BASE, D DRAWER BASE, MD DESK W/

DRAWER, DC DISPLAY CASE, T TALL WITH

GLASS DOORS, W WALL WITH GLASS

DOORS

1ST 2 DIGITS = CABINET WIDTH (INCHES)

2ND 2 DIGITS = CABINET HEIGHT

CABINET LEGEND

3RD 2 DIGITS = CABINET DEPTH

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

A-421

IN

T

E R

IO

R

E L

E V

A T

IO

N

S

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

O H

IO

L

O U

IS

V

IL

L

E D

IS

T

R

IC

T L

O U

IS

V

IL

L

E K

E N

T U

C K

Y

R C

U R

R A

N

R W

IL

L

IA

M S

S K

IM

B

A L L

J S

W E

E N

E Y

J U

N E

W Q

R R

CERTIFIED FINAL

R E

N O

V A

T E

R E

S E

A R

C H

F A

C

IL

IT

Y

F O

R H

Y P

E R

S O

N

IC

S L

A B

F

/2

P R

O J E

C T

Z

H T

V

P

SCALE: 1/4" = 1'-0"

A3

INTERIOR ELEVATION - RM 193

SCALE: 1/4" = 1'-0"

A6

INTERIOR ELEVATION - RM 193

SCALE: 1/4" = 1'-0"

C7

INTERIOR ELEVATION - RM 193

SCALE: 1/4" = 1'-0"

F7

INTERIOR ELEVATION - RM 195

SCALE: 1/4" = 1'-0"

F5

INTERIOR ELEVATION - RM 195

SCALE: 1/4" = 1'-0"

D7

INTERIOR ELEVATION - RM 193

SCALE: 1/4" = 1'-0"

A1

INTERIOR ELEVATION - RM 193

SCALE: 1/4" = 1'-0"

C5

INTERIOR ELEVATION - RM 193

SCALE: 1/4" = 1'-0"

C1

INTERIOR ELEVATION - RM 193

SCALE: 1/4" = 1'-0"

D5

INTERIOR ELEVATION - RM 193

SCALE: 1/4" = 1'-0"

F3

INTERIOR ELEVATION - RM 195

SCALE: 1/4" = 1'-0"

F1

INTERIOR ELEVATION - RM 195

SCALE: 1/4" = 1'-0"

D1

INTERIOR ELEVATION - RM 193

SCALE: 1/4" = 1'-0"

C3

INTERIOR ELEVATION - RM 193

TOOTH IN CMU INFILL

BRACKET MTD

EXTINGUISHER

STAINLESS STEEL

COUNTERTOP AND

SPLASH

LOCATION FOR TV/MONITOR

(GFGI)

GAS CABINETS (GFGI)

VERTICAL UTILITY CHASE

BY CASEWORK

MANUFACTURER

CHEMICAL RESISTANT

RESIN COUNTERTOP

CHEMICAL RESISTANT

RESIN COUNTERTOP

AND SPLASH

DISPLAY CASE WITH ADJUSTABLE

SHELVES AND STORAGE BELOW

0' 2' 4' 8'0' 2' 4' 8'0' 2' 4' 8'

0' 2' 4' 8'0' 2' 4' 8'0' 2' 4' 8'0' 2' 4' 8'

0' 2' 4' 8'0' 2' 4' 8'0' 2' 4' 8'

0' 2' 4' 8'0' 2' 4' 8'0' 2' 4' 8'0' 2' 4' 8'

A

M E

N D

M E

N T

/2

/2

1 1

W

2Q R

R

_P la ns -0

DOOR TYPES

HG/F

1/4" CLEAR

FULLY

TEMPERED

GLASS

6"2' - 0"

/2

1' - 11 3/4"

F HG FG FG/F

FIRE RATED CLEAR

GLASS

FRAME TYPES

2" 2"

SEE

SCHEDULE

S E

E S

C H

E D

U L E

CONTINOUS

SEALANT ALL

AROUND EACH

SIDE

DOOR

AND FRAME

REFER TO

SCHEDULE

PUNCH&

DIMPLE

ANCHOR

EXISTING

CMU

CONTINOUS SEALANT

ALL AROUND EACH SIDE

DOOR AND FRAME

REFER TO SCHEDULE

HARDWARE SETS

SET NO. 1

DOOR NUMBER: PH1 193, 191A, 188A

PH2 185, 183, 197, 199

4 HINGES EACH LEAF FBB179 4.5"X4.5" 626 STANLEY

1 CYLINDER CLASSROOM LOCK 9K37R 15D LS 630 STANLEY

1 CLOSER W/STOP CLD-4550 S 689 STANLEY

2 MANUAL FLUSH BOLTS 555 12" US26D ROCKWOOD

3 SILENCERS PER LEAF 608/609 ROCKWOOD

OPTION:

CARD READER (SEE SPECIFICATIONS)

1 ELECTRIC STRIKE 500D 501 12/24 VDC/VAC 630 HES

SET NO. 2

DOOR NUMBER: PH1 188B, 191B

3 HINGES FBB179 4.5"X4.5" 626 STANLEY

1 CYLINDER CLASSROOM LOCK 9K37D 15D LS 626 STANLEY

1 CLOSER W/STOP CLD-4550 S 689 STANLEY

3 SILENCERS 608/609 ROCKWOOD

SET NO. 3

DOOR NUMBER: PH1 195

3 HINGES FBB179 4.5"X4.5" 626 STANLEY

1 CYLINDER CLASSROOM LOCK 9K37D 15D LS 626 STANLEY

1 CLOSER W/STOP CLD-4550 S 689 STANLEY

WEATHERSTRIPPING SEALS 785SN MIL HAGER

1 DOOR SWEEP ` 756SV MIL HAGER

SET NO. 4

DOOR NUMBER: PH1 UC17A, UC17B, UC17C, UC17D

PH2 UC14A, UC14B, UC14C, UC14D

3 HINGES FBB179 4.5"X4.5" 626 STANLEY

1 CYLINDER STOREROOM LOCK 9K37D 15D S3 630 STANLEY

1 CLOSER S/STOP CLD-4550 S 689 STANLEY

3 SILENCERS 608/609 ROCKWOOD

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

A-601

D O

O R

S C

H E

D U

L E

A N

D D

E T

A

IL

S

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

O H

IO

L

O U

IS

V

IL

L

E D

IS

T

R

IC

T L

O U

IS

V

IL

L

E K

E N

T U

C K

Y

R C

U R

R A

N

R W

IL

L

IA

M S

S K

IM

B

A L L

J S

W E

E N

E Y

J U

N E

W Q

R R

CERTIFIED FINAL

R E

N O

V A

T E

R E

S E

A R

C H

F A

C

IL

IT

Y

F O

R H

Y P

E R

S O

N

IC

S L

A B

F

/2

P R

O J E

C T

Z

H T

V

DOOR SCHEDULE - PHASE 1

DOORS FRAME

F

IR

E R

A T

IN

G

H A

R D

W A

R E

C O

M M

E N

T S

M A

R K

D O

O R

T Y

P E

N U

M B

E R

O F

P A

N E

L

S SIZE

M A

T E

R

IA

L

F

IN

IS

H

G L A

S S

T Y

P E

T Y

P E

M A

T E

R

IA

L

F

IN

IS

H

DETAILS

W

ID

T H

H E

IG

H

T

T H

IC

K

N E

S S

H E

A D

J A

M B

S

IL

L

188A HG/F 2 5' - 0" 8' - 10" 1 3/4" HM PT FIRE RATED 1 HM PT H1 J1 45 MIN 1 R1, R3

188B HG 1 3' - 0" 7' - 2" 1 3/4" HM PT 1/4"

TEMPERED

1 HM PT 2

191A HG/F 2 5' - 0" 8' - 10" 1 3/4" HM PT FIRE RATED 1 HM PT H1 J1 45 MIN 1 R1, R3

191B HG 1 3' - 0" 7' - 2" 1 3/4" HM PT 1/4"

TEMPERED

1 HM PT H1 J1 2

193 FG/F 2 5' - 0" 8' - 10" 1 3/4" HM PT FIRE RATED 1 HM PT H1 J1 45 MIN 1 R1, R3

195 FG 1 3' - 0" 7' - 2" 1 3/4" HM PT 1/4"

TEMPERED

1 HM PT H1 J1 3 R2

UC17A F 1 1' - 8" 7' - 2" 1 3/4" HM PT - 1 HM PT H1 J1 60 MIN 4

UC17B F 1 1' - 8" 7' - 2" 1 3/4" HM PT - 1 HM PT H1 J1 60 MIN 4

UC17C F 1 1' - 8" 7' - 2" 1 3/4" HM PT - 1 HM PT H1 J1 60 MIN 4

UC17D F 1 1' - 8" 7' - 2" 1 3/4" HM PT - 1 HM PT H1 J1 60 MIN 4

COMMENTS:

R1 OPTION 1: CARD READER

R2 SEAL OPENING

R3 36" W ACTIVE LEAF AND 24" W

INACTIVE LEAF

MATERIAL ABBREVIATIONS

AL ALUMINUM PT PAINT FINISH

DA DARK ANODIZED FINISH ST STAIN FINISH

HM HOLLOW METAL WD WOOD

EX TO MATCH EXISTING

SCALE: 3" = 1'-0"

D3

DOOR JAMB DETAIL - J1

SCALE: 3" = 1'-0"

D1

DOOR HEAD DETAIL - H1

DOOR SCHEDULE - PHASE 2

DOORS FRAME

F

IR

E R

A T

IN

G

H A

R D

W A

R E

C O

M M

E N

T S

M A

R K

D O

O R

T Y

P E

N U

M B

E R

O F

P A

N E

L

S SIZE

M A

T E

R

IA

L

F

IN

IS

H

G L A

S S

T Y

P E

T Y

P E

M A

T E

R

IA

L

F

IN

IS

H

DETAILS

W

ID

T H

H E

IG

H

T

T H

IC

K

N E

S S

H E

A D

J A

M B

S

IL

L

183 HG/F 2 5' - 0" 8' - 10" 1 3/4" HM PT FIRE RATED 1 HM PT H1 J1 45 MIN 1 R1

185 HG/F 2 5' - 0" 8' - 10" 1 3/4" HM PT FIRE RATED 1 HM PT H1 J1 45 MIN 1 R1

197 HG/F 2 5' - 0" 8' - 10" 1 3/4" HM PT FIRE RATED 1 HM PT H1 J1 45 MIN 1 R1

199 HG/F 2 5' - 0" 8' - 10" 1 3/4" HM PT FIRE RATED 1 HM PT H1 J1 45 MIN 1 R1

UC14A F 1 1' - 8" 7' - 2" 1 3/4" HM PT - 1 HM PT H1 J1 60 MIN 4

UC14B F 1 1' - 8" 7' - 2" 1 3/4" HM PT - 1 HM PT H1 J1 60 MIN 4

UC14C F 1 1' - 8" 7' - 2" 1 3/4" HM PT - 1 HM PT H1 J1 60 MIN 4

UC14D F 1 1' - 8" 7' - 2" 1 3/4" HM PT - 1 HM PT H1 J1 60 MIN 4

A

M E

N D

M E

N T

/2

/2

0' 6"4"2"0' 6"4"2"

1 1

1 1

W

2Q R

R

_P la ns -0

K J H

RELO

K J H

3 4 RELO

PHASE 1

PHASE 2

BUILDING 655

ROOMS

155A & B

ROOM

ROOM

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

PLAN NORTH

KEY PLAN

FD101

F

IR

E P

R O

T E

C T

IO

N

D E

M O

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

O H

IO

L

O U

IS

V

IL

L

E D

IS

T

R

IC

T L

O U

IS

V

IL

L

E K

E N

T U

C K

Y

R P

A T

R

IC

K

T V

A N

D O

R P

E

S K

IM

B

A L L

R B

J O

R E

N S

E N

J U

N E

W Q

R R

CERTIFIED FINAL

R E

N O

V A

T E

R E

S E

A R

C H

F A

C

IL

IT

Y

F O

R H

Y P

E R

S O

N

IC

S L

A B

F

/2

P R

O J E

C T

Z

H T

V

1/8" = 1'-0"1

FIRE PROTECTION DEMOLITION PLAN - PHASE 1

FireLogix Engineering, Ltd.

215 North Broadway Street

Lebanon, Ohio 45036

(513) 206-9651 www.firelogix.com

KEY NOTES

1 FIRE ALARM / MASS NOTIFICATION DEVICES ARE

EXISTING TO REMAIN UNLESS NOTED OTHERWISE, SEE

NEW WORK PLANS (TYPICAL).

2 DEMOLISH EXISTING SPRINKLER HEADS AND

RECONFIGURE BRANCH LINES (IF SUITABLE, SEE

GENERAL NOTE #4 ABOVE) AS NEEDED WITHIN PROJECT

AREA. SEE NEW WORK PLANS.

3 EXISTING SPRINKLER MAIN TO REMAIN.

4 NO WORK THIS PHASE IN HATCHED AREA.

5 DEMOLISH EXISITNG SPRINKLER HEAD IN WALK-IN FUME

HOOD.

6 RELOCATE EXISTING NOTIFICATION APPLIANCES TO NEW

LOCATIONS SHOWN ON NEW WORK.

7 SPRINKLERS IN CORRIDORS ARE EXISTING TO REMAIN.

A

M E

N D

M E

N T

/2

/2

1/8" = 1'-0"2

FIRE PROTECTION DEMOLITION PLAN - PHASE 2

0' 8' 12'4' 0' 8' 12'4'

GENERAL NOTES (DEMOLITION)

1 COMPLY WITH USACE EM 385-1-1 FOR ALL WORK.

2 COMPLY WITH NFPA 241 FOR ALL WORK.

3 EXISTING CONDITIONS, EQUIPMENT, MATERIALS & SIZES ARE

SHOWN FOR REFERENCE ONLY. VERIFY EXISTING CONDITIONS

AND BRING ANY DISCREPANCIES TO THE DOR'S ATTENTION IN

WRITING.

4 AN EXISTING FIRE SPRINKLER SYSTEM IS INSTALLED

THROUGHOUT THE BUILDING. THE FIRE SPRINKLER HEADS IN

THE PROJECT AREA ARE TO BE DEMOLISHED AND REPLACED.

TEST EXISTING BRANCHLINE PIPING IN ACCORDANCE WITH

NFPA 13 TO VERIFY IT IS SUITABLE TO REMAIN. RECONFIGURE

EXISTING LAYOUT TO MATCH NEW LAYOUT. IN THE EVENT THAT

NFPA 13 TESTING INDICATES PIPING IS NOT SUITABLE TO

REMAIN CONTACT CONTRACTING OFFICER FOR DIRECTION ON

HOW TO PROCEED.

5 EXISTING FIRE ALARM NOTIFICATION APPLIANCES, INITIATING

DEVICES, AND APPURTENANCES IN THE PROJECT AREA ARE

EXISTING TO REMAIN, UNLESS NOTED OTHERWISE.

6 RESTORE SURFACES, FINISHES, CEILING TILES, ETC. WHICH ARE

DAMAGED AS PART OF THE DEMOLITION PROCESS.

7 PERFORM ANY FIRE ALARM REMOVAL AND DEMOLITION WORK

WITH MINIMAL INTERFERENCE WITH EXISTING SYSTEMS WHICH

SHALL REMAIN. ENSURE THAT ANY DEVICES LOCATED OUTSIDE

OF DEMOLITION WORK AREA ARE NOT AFFECTED BY REMOVAL

OF WIRING AND/OR CIRCUITING. WIRING/CONDUIT SHALL BE

LEFT IN A SAFE CONDITION, LABELED FOR ITS USE, AND

EXTENDED AS REQUIRED TO MAINTAIN CIRCUIT CONTINUITY,

INCLUDING ALL APPLICABLE CONTROLS.

8 PROVIDE AND MAINTAIN ANY CONNECTIONS/DISCONNECTIONS

AS NEEDED TO ENSURE ADEQUATE SAFETY AND PROTECTION

OF ALL PERSONNEL AND EQUIPMENT.

9 PERFORM REMOVAL AND DEMOLITION WORK WITH MINIMAL

INTERFERENCE TO EXISTING NON FIRE ALARM SYSTEMS WHICH

SHALL REMAIN.

10 AN EXISTING FIRE ALARM SYSTEM IS CURRENTLY INSTALLED

THROUGHOUT THE BUILDING. MAINTAIN THE EXISTING SYSTEM

IN OPERATION.

06/04/2021

W

2Q R

R

_P la ns -0

K J H

K J H

LAB

LAB

LAB

ME-1

ME-1

LAB

191 1

PHASE 1

PHASE 2

BUILDING 655

ROOMS

155A & B

ROOM

ROOM

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

PLAN NORTH

KEY PLAN

FX101

F

IR

E S

P R

IN

K

L E

R P

L A

N

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

O H

IO

L

O U

IS

V

IL

L

E D

IS

T

R

IC

T L

O U

IS

V

IL

L

E K

E N

T U

C K

Y

R P

A T

R

IC

K

T V

A N

D O

R P

E

S K

IM

B

A L L

R B

J O

R E

N S

E N

J U

N E

W Q

R R

CERTIFIED FINAL

R E

N O

V A

T E

R E

S E

A R

C H

F A

C

IL

IT

Y

F O

R H

Y P

E R

S O

N

IC

S L

A B

F

/2

P R

O J E

C T

Z

H T

V

1/8" = 1'-0"1

FIRE SPRINKLER PLAN - PHASE 2

GENERAL NOTES (FIRE SPRINKLER)

9 CONDUCT WATERFLOW TESTS, IN ACCORDANCE WITH THE PROCEDURES

CONTAINED IN NFPA 291 TO DETERMINE AVAILABLE WATER SUPPLY FOR THE

WATER-BASED FIRE EXTINGUISHING SYSTEMS. THE FLOW TEST MUST BE

PERFORMED UNDER THE DIRECTION OF THE QFPE. HYDRAULIC CALCULATIONS

SHOULD BE BASED ON A WATERFLOW TEST THAT WAS PERFORMED NO MORE

THAN 6 MONTHS PRIOR TO SUBMISSION OF THE CALCULATIONS.

10 PRIOR TO DEMOLTION OF THE SPRINKLER SYSTEM WITHIN THE PROJECT AREA,

INSTALL TEMPORARY HEAT DETECTION THROUGHOUT. THE HEAT DETECTION

SHALL BE CONNECTED TO THE EXISTING BUILDING FIRE ALARM SYSTEM FOR

PROPER MONITORING. THE HEAT DETECTION SHALL BE INSTALLLED AND TESTED

PER NFPA 72 REQUIREMENTS. THE HEAT DETECTION SHALL REMAIN ACTIVE UNTIL

THE NEW SPRINKLER SYSTEM IS FULLY ACTIVE, TESTED AND ACCEPTED.

10 PRIOR TO DEMOLTION OF THE SPRINKLER SYSTEM WITHIN THE PROJECT AREA,

INSTALL TEMPORARY HEAT DETECTION THROUGHOUT. THE HEAT DETECTION

SHALL BE CONNECTED TO THE EXISTING BUILDING FIRE ALARM SYSTEM FOR

PROPER MONITORING. THE HEAT DETECTION SHALL BE INSTALLLED AND TESTED

PER NFPA 72 REQUIREMENTS. THE HEAT DETECTION SHALL REMAIN ACTIVE UNTIL

THE NEW SPRINKLER SYSTEM IS FULLY ACTIVE, TESTED AND ACCEPTED.

GENERAL NOTES (FIRE SPRINKLER)

6 DESIGN ANY PORTIONS OF THE SPRINKLER SYSTEM THAT ARE NOT INDICATED ON

THE DRAWINGS INCLUDING LOCATING SPRINKLERS, PIPING AND EQUIPMENT, AND

SIZE PIPING AND EQUIPMENT WHEN THIS INFORMATION IS NOT INDICATED ON THE

DRAWINGS OR IS NOT SPECIFIED HEREIN. PIPE ROUTING SHOWN IS CONCEPTUAL

IN NATURE. COORDINATE WITH CONDITIONS AND ALL TRADES.

7 AFTER BECOMING FAMILIAR WITH ALL DETAILS OF THE WORK, VERIFY ALL

DIMENSIONS AND LOCATIONS IN THE FIELD, AND ADVISE THE ENGINEER OF

RECORD OF ANY DISCREPANCY BEFORE PERFORMING THE WORK.

8 HYDRAULIC CALCULATIONS MUST INCLUDE A MINIMUM PRESSURE DROP ACROSS

BACKFLOW PREVENTERS. FOR A REDUCED PRESSURE BACKFLOW PREVENTER,

USE A MINIMUM OF 12 PSI. FOR A DOUBLE CHECK BACKFLOW PREVENTER, USE A

MINIMUM OF 8 PSI .

8 HYDRAULIC CALCULATIONS MUST INCLUDE A MINIMUM PRESSURE DROP ACROSS

BACKFLOW PREVENTERS. FOR A REDUCED PRESSURE BACKFLOW PREVENTER,

USE A MINIMUM OF 12 PSI. FOR A DOUBLE CHECK BACKFLOW PREVENTER, USE A

MINIMUM OF 8 PSI .

9 CONDUCT WATERFLOW TESTS, IN ACCORDANCE WITH THE PROCEDURES

CONTAINED IN NFPA 291 TO DETERMINE AVAILABLE WATER SUPPLY FOR THE

WATER-BASED FIRE EXTINGUISHING SYSTEMS. THE FLOW TEST MUST BE

PERFORMED UNDER THE DIRECTION OF THE QFPE. HYDRAULIC CALCULATIONS

SHOULD BE BASED ON A WATERFLOW TEST THAT WAS PERFORMED NO MORE

THAN 6 MONTHS PRIOR TO SUBMISSION OF THE CALCULATIONS.

GENERAL NOTES (FIRE SPRINKLER)

1 PROVIDE COMPLETE AUTOMATIC SPRINKLER SYSTEM FOR THE RENOVATED

AREAS. A SINGLE EXISTING SPRINKLER RISER SERVES THE FACILITY. THE

EXISTING SPRINKLER RISER IS LOCATED ON THE EAST EXTERIOR WALL OF THE

GROUND FLOOR MECHANICAL ROOM. THE LOCATION OF THE RISER IS NOTED ON

THE PLANS. EXISTING SPRINKLER RISER IS TO REMAIN.

2 REPLACE ALL EXISTING SPRINKLER HEADS THROUGHOUT THE PROJECT AREA AND

PROVIDE NEW HEADS TO MATCH THE NEW LAYOUT AND CEILING GRID IN

ACCORDANCE WITH THE DESIGN CRITERIA SHOWN. TEST EXISTING BRANCHLINE

PIPING TO DETERMINE IF IT IS SUITABLE TO REMAIN OR IF NEW PIPING IS

REQUIRED. TEST EXISTING PIPING IN ACCORDANCE WITH NFPA 13. IF TESTING

SHOWS PIPING TO BE SUITABLE TO REMAIN, RECONFIGURE EXISTING LAYOUT TO

MATCH THE NEW LAYOUT. IF TESTING SHOWS THE PIPING TO BE UNSUITABLE TO

REMAIN, CONTACT THE CONTRACTING OFFICER FOR DIRECTION ON HOW TO

PROCEED.

3 FURNISH PIPING OFFSETS, FITTINGS, AND ANY OTHER ACCESSORIES AS REQUIRED

TO PROVIDE A COMPLETE INSTALLATION AND TO ELIMINATE INTERFERENCE WITH

OTHER CONSTRUCTION.

4 INSTALL SPRINKLER SYSTEM OVER AND UNDER DUCTS, PIPING AND PLATFORMS

WHEN SUCH EQUIPMENT CAN NEGATIVELY AFFECT OR DISRUPT THE SPRINKLER

DISCHARGE PATTERN AND COVERAGE.

5 PIPE SIZES WHICH ARE NOT INDICATED ON DRAWINGS SHALL BE DETERMINED BY

HYDRAULIC CALCULATION.

FireLogix Engineering, Ltd.

215 North Broadway Street

Lebanon, Ohio 45036

(513) 206-9651 www.firelogix.com

KEY NOTES

1 IF NFPA 13 TESTING SHOWS THAT EXISTING BRANCHLINE

PIPING IS SUITABLE TO REMAIN, RECONFIGURE BRANCH

LINES AS NEEDED AND PROVIDE NEW HEADS IN

ACCORDANCE WITH FIRE SPRINKLER DESIGN CRITERIA

TO ACCOMMODATE NEW FLOOR PLAN AND CEILINGS

(TYPICAL THROUGHOUT PROJECT AREA).

2 ALL MAINS IN THE CORRIDORS ARE EXISTING TO REMAIN.

FIRE SPRINKLER SYSTEM COVERING PROJECT AREA

APPEARS TO BE GRIDDED, SEE FX501 FOR FULL

SPRINKLER MAIN ROUTING IN THIS AREA.

3 ALL NEW FIRE SPRINKLER WORK IS ORDINARY HAZARD IN

ACCORDANCE WITH UFC 3-600-01.

4 PROVIDE SPRINKLER PROTECTION IN KARDEX UNIT IN

ACCORDANCE WITH MANUFACTURER GUIDELINES.

5 NO WORK THIS PHASE IN HATCHED AREA.

6 WALK-IN FUME HOOD IS EXISTING TO REMAIN, REPLACE

EXISTING SPRINKLER HEAD INSIDE THE UNIT.

7 SPRINKLERS IN CORRIDORS ARE EXISTING TO REMAIN.

8 TO SUPPLY, UP FROM RISER ON GROUND FLOOR, SEE

FX501.

9 PROVIDE SPRINKLER PROTECTION INSIDE HYDROGEN

GAS CABINET.

A

M E

N D

M E

N T

/2

/2

0' 8' 12'4' 1/8" = 1'-0"2

FIRE SPRINKLER PLAN - PHASE 1

0' 8' 12'4'

06/04/2021

W

2Q R

R

_P la ns -0

1. REFER TO FINISH SCHEDULE, LEGEND, PLAN, DETAILS, AND SPECIFICATIONS

FOR ADDITIONAL INFORMATION.

2. REFER TO ARCHITECTS DRAWINGS FOR PARTITION DETAILS AND BLOCKING

LOCATIONS.

3. FINISH PLAN DENOTES CHANGE IN FLOORING MATERIAL; USE APPROPRIATE

TRANSITION STRIP WHERE DISSIMILAR FLOOR FINISHES ABUT. REFER TO

SHEET I-501 FOR DETAILS.

4. INTERIOR WALL FINISH AND COLOR SHALL APPLY TO ALL WALL SURFACES,

INCLUDING, BUT NOT LIMITED TO, REVEALS, VERTICAL FURRED SPACES,

GRILLS, DIFFUSERS, ELECTRICAL AND ACCESS PANELS, AND PIPING AND

CONDUIT ADJACENT TO WALL SPACES UNLESS OTHERWISE SPECIFIED.

FINISH COLORS OF FIRE EXTINGUISHER CABINETS, RECEPTACLE BODIES AND

PLATES, FIRE ALARMS/WARNING LIGHTS, EMERGENCY LIGHTING AND OTHER

MISCELLANEOUS ITEMS SHALL BE COORDINATED WITH THE BUILDING

INTERIOR. COLOR OF EQUIPMENT ON CEILINGS OR WALLS (SPEAKERS,

SMOKE DETECTORS, AIR GRILLES, ETC) SHALL MATCH THE CEILING OR WALL

COLOR.

5. ITEMS NOT SPECIFIED ELSEWHERE SHALL BE PAINTED TO MATCH ADJACENT

WALL SURFACES.

6. ALL WALL PAINT TO BE SEMI-GLOSS FINISH, REGARDLESS OF COLOR UNLESS

OTHERWISE NOTED. EPOXY PAINT TO BE GLOSS FINISH.

7. ALL HOLLOW METAL DOORS AND FRAMES TO BE SEMI-GLOSS FINISH UNLESS

OTHERWISE NOTED.

8. REFER TO ABA STANDARDS FOR ALL SIGNAGE REQUIREMENTS.

9. CONFIRM ALL TEXT WITH CLIENT.

10. ALL 1" TALL AND 1-1/2" TALL TEXT SHALL BE HELVETICA NEUE, 65

MEDIUM. ALL 3/4" TALL TEXT TO BE HELVETICA NEUE, 55 ROMAN.

11. SIGNAGE IS BASED ON WPAFB SIGN STANDARD, BASIS OF DESIGN

MANUFACTURER: TAKEFORM, PRODUCT: FUSION.

12. REFER TO SIGNAGE PLANS FOR LOCATIONS OF SIGNS.

13. PROVIDE SOFTWARE AND TRAINING FOR CHANGEABLE INSERT STRIPS TO BE

EDITED ON CLIENT'S COMPUTER.

14. REFER TO I-501 FOR SIGNAGE TYPES. REFER TO SIGNAGE SCHEDULE,

DETAILS, AND TYPICALS FOR ADDITIONAL INFORMATION.

15. REFER TO FINISHES AS NOTED ON TYPICAL ROOM SIGN. FINAL SIGNAGE

COLORS SHALL BE SELECTED FROM SELECTED MANUFACTURER'S FULL

STANDARD LINE AND SHALL CORRESPOND AND COORDINATE WITH WPAFB

SIGNAGE STANDARD FINISHES.

16. CONTRACTORS ARE FREE TO USE ANY PRODUCT WHICH MEETS THE

GOVERNMENT'S MINIMUM REQUIREMENTS AND IS NOT IN CONFLICT WITH

OTHER CONTRACT PROVISIONS. UNLESS INDICATED OTHERWISE ON THE

PLANS OR SPECIFICATIONS, ALL LISTED MANUFACTURERS ARE THE BASIS OF

DESIGN. FOR THESE BASIS OF DESIGN PRODUCTS, OTHER

MANUFACTURERS MAY BE SUBSTITUTED AS LONG AS THE STANDARD OF

QUALITY AND CHARACTERISTICS OF THE SUBSTITUTED MANUFACTURER

MEET OR EXCEED THE STANDARD OF QUALITY AND CHARACTERISTICS OF

THE BASIS OF DESIGN.

GENERAL NOTES

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

I-601

IN

T

E R

IO

R

S C

H E

D U

L E

S

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

O H

IO

L

O U

IS

V

IL

L

E D

IS

T

R

IC

T L

O U

IS

V

IL

L

E K

E N

T U

C K

Y

A G

E N

T R

Y

A G

E N

T R

Y

S K

IM

B

A L L

J S

W E

E N

E Y

J U

N E

W Q

R R

CERTIFIED FINAL

R E

N O

V A

T E

R E

S E

A R

C H

F A

C

IL

IT

Y

F O

R H

Y P

E R

S O

N

IC

S L

A B

F

/2

P R

O J E

C T

Z

H T

V

ROOM SIGNAGE SCHEDULE - PHASE 1

MARK SIGN NUMBER SIGN TEXT SIGN TYPE

MOUNTING INFO

HEIGHT

CENTER OF

SIGN AFF WALL/DOOR

5 193 - A1 5' - 0" DOOR

6 195 - A1 5' - 0" WALL

7 191 - A1 5' - 0" DOOR

8 188 - A1 5' - 0" DOOR

ROOM SIGNAGE SCHEDULE - PHASE 2

MARK SIGN NUMBER SIGN TEXT SIGN TYPE

MOUNTING INFO

HEIGHT

CENTER OF

SIGN AFF WALL/DOOR

1 185 - A1 5' - 0" DOOR

2 183 - A1 5' - 0" DOOR

3 199 - A1 5' - 0" DOOR

4 197 - A1 5' - 0" DOOR

A

M E

N D

M E

N T

/2

/2

ROOM FINISH SCHEDULE - PHASE 1

ROOM NO FLOOR MAT. BASE FINISH

WALL FINISH CEILING

MAT. NOTESNORTH EAST SOUTH WEST

188 QT QTB P1 P1 P1 P1 ACT

191 QT QTB P1 P1 P1 P1 ACT

193 QT QTB P1 P1 P1 P1 ACT

195 EF RB EP1 EP1 EP1 EP1 ACT

ROOM FINISH SCHEDULE - PHASE 2

ROOM NO FLOOR MAT. BASE FINISH

WALL FINISH CEILING

MAT. NOTESNORTH EAST SOUTH WEST

183 EF RB P1 P1 P1 P1 ACT

185 EF RB P1 P1 P1 P1 ACT

197 EF RB P1 P1 P1 P1 ACT

199 EF RB P1 P1 P1 P1 ACT

EPOXY GROUT - CUSTOM GROUT SOLUTIONS COLOR: #145 LIGHT SMOKE GROUT AT QUARRY TILE

EPOXY RESIN COUNTERTOP - KEWAUNEE KEMRESIN COUNTERTOP, COLOR: BLACK

CASEWORK - KEWAUNEE STEEL WITH OVERLAY SQUARE EDGE AND ALUMINUM RECESSED

PULLS, COLOR: BLACK

TRANSITION STRIP TS2 ROPPE #50 ADAPTER, COLOR: BLACK

TRANSITION STRIP TS1 SCHLUTER SYSTEMS RENO-U, COLOR: STAINLESS STEEL

EXISTING TO REMAIN ETR - - -

QUARRY TILE BASE QTB DALTILE COVE BASE, COLOR: Q3565, SIZE: 5" X 6" REFER TO INSTALLATION

DETAIL

RUBBER BASE RB ROPPE PINNACLE RUBBER, P100, SIZE: 4", COLOR: BLACK

ACOUSTIC CEILING ACT ARMSTRONG #1715B MYLAR, SIZE: 24" X 24", SQUARE EDGE, COLOR: WHITE USE WITH PRELUDE XL GRID

QUARRY TILE QT DALTILE COLOR: RED BLAZE 0Q40, SIZE: 6" X 6", ABRASIVE FINISH

EPOXY FLOORING EF TORGINOL DECOFLAKE 1/4", COLOR: FB-506 RAPIDS

EPOXY PAINT EP1 SHERWIN WILLIAMS COLOR: SW7070 SITE WHITE EPOXY PAINT IN CLEAN

ROOM

ENAMEL PAINT P2 SHERWIN WILLIAMS COLOR: SW6228 REFUGE DOORS AND FRAMES

ENAMEL PAINT P1 SHERWIN WILLIAMS COLOR: SW7070 SITE WHITE FIELD PAINT

MATERIALS CODE MFG SPECIFICATION NOTES

INTERIOR MATERIALS LEGEND

W

2Q R

R

_P la ns -0

ME

K J H

ME

EXISTING WALK-

IN FUME HOOD

TO REMAIN

142 143

151 153 152

119 120 121

147 154 149

155 156

150 146

052046

047 048

039070

063 064 065

063 071 056

EXISTING FUME HOOD TO BE REMOVED

FILE CABINET AND DESK TO

BE REMOVED

ITEM 133 AND 134

EXHAUST HOODS ABOVE

(4) RELOCATED LOCKERS FROM RM 188 AND 191

EXISTING WORKSTATIONS IN

THIS AREA REMAIN HOWEVER

SHIFTING THEM TO CREATE

STORAGE SPACE IS

ACCEPTABLE

STORAGE RACKS

RELOCATED FROM RM 193

ITEM #062 AND #144

(2) RELOCATED LOCKERS FROM RM 193

PHASE 1

PHASE 2

BUILDING 655

ROOMS

155A & B

ROOM

ROOM

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

PLAN NORTH

KEY PLAN

Q-401

E N

L A

R G

E D

P H

A S

E

E Q

U

IP

M E

N T

P L

A N

E

X

IS

T

IN

G

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

O H

IO

L

O U

IS

V

IL

L

E D

IS

T

R

IC

T L

O U

IS

V

IL

L

E K

E N

T U

C K

Y

R C

U R

R A

N

B C

H E

R R

Y

S K

IM

B

A L L

J S

W E

E N

E Y

J U

N E

W Q

R R

CERTIFIED FINAL

R E

N O

V A

T E

R E

S E

A R

C H

F A

C

IL

IT

Y

F O

R H

Y P

E R

S O

N

IC

S L

A B

F

/2

P R

O J E

C T

Z

H T

V

SCALE: 1/4" = 1'-0"

A1

ENLARGED EQUIPMENT PLAN - PHASE 1 - EXISTING

0' 4' 8' 16'

A

M E

N D

M E

N T

/2

/2

SCALE: 1/8" = 1'-0"

C8

PH1 RM 136 - NEW WORK

0' 4' 8' 16'

W

2Q R

R

_P la ns -0

Freezer

R E

F

K J H

011 012

027 028

030 034

088092093

113 100

101110

108 104

EQUIPMENT IN THIS LOCATION TO

BE REMOVED AND STORED PRIOR

TO PHASE 1 DEMOLITION. LOCATION

TO BE DETERMINED BY OWNER.

EXISTING FUME HOOD TO BE REMOVED

EXISTING FUME HOODS TO BE REMOVED

EXISTING FUME HOODS TO BE REMOVED

ITEM #87 EXHAUST

FUME HOOD ABOVE

PHASE 1

PHASE 2

BUILDING 655

ROOMS

155A & B

ROOM

ROOM

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

PLAN NORTH

KEY PLAN

Q-402

E N

L A

R G

E D

P H

A S

E

E Q

U

IP

M E

N T

P L

A N

E

X

IS

T

IN

G

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

O H

IO

L

O U

IS

V

IL

L

E D

IS

T

R

IC

T L

O U

IS

V

IL

L

E K

E N

T U

C K

Y

R C

U R

R A

N

B C

H E

R R

Y

S K

IM

B

A L L

J S

W E

E N

E Y

J U

N E

W Q

R R

CERTIFIED FINAL

R E

N O

V A

T E

R E

S E

A R

C H

F A

C

IL

IT

Y

F O

R H

Y P

E R

S O

N

IC

S L

A B

F

/2

P R

O J E

C T

Z

H T

V

SCALE: 1/4" = 1'-0"

A1

ENLARGED EQUIPMENT PLAN - PHASE 2 - EXISTING

0' 4' 8' 16'

A

M E

N D

M E

N T

/2

/2

W

2Q R

R

_P la ns -0

K J H

A-421A6

C7

A3

A-421F7 F5

A-422

A2

A-421 C5

A1

D7

A-421 C1

D5

A-422

A1

A5 C4

A-422

D1 F3

F1 D4

C1

D1

C3

ME

119 120 121

159 157 117 118

069 070

115A

150 146

045046

170169

TV

068 071

GAS

APPLY NEW 5/16" THICK ALUMINUM

PLATE TOP OVER ENTIRE FURNACE

STAND. USE OLD TOP AS A TEMPLATE.

GAS

ITEM 133 AND 134

EXHAUST HOODS ABOVE

11' - 8"

19' - 4"

/8

/8

RELOCATE SPS UNIT,

CHILLER AND

TRANSFORMER FROM

ROOM 191 (EQUIP. ITEMS

#130, 131 AND 132 SHOWN

ON Q-401)

(4) RELOCATED LOCKERS FROM RM 188 AND 191

EXISTING WORKSTATIONS IN

THIS AREA REMAIN HOWEVER

SHIFTING THEM TO CREATE

STORAGE SPACE IS

ACCEPTABLE

STORAGE RACKS

RELOCATED FROM RM 193

ITEM #062 AND #144

(2) RELOCATED LOCKERS FROM RM 193

PHASE 1

PHASE 2

BUILDING 655

ROOMS

155A & B

ROOM

ROOM

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

PLAN NORTH

KEY PLAN

Q-411

E N

L A

R G

E D

P H

A S

E

E Q

U

IP

M E

N T

P L

A N

N

E W

W O

R K

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

O H

IO

L

O U

IS

V

IL

L

E D

IS

T

R

IC

T L

O U

IS

V

IL

L

E K

E N

T U

C K

Y

R C

U R

R A

N

B C

H E

R R

Y

S K

IM

B

A L L

J S

W E

E N

E Y

J U

N E

W Q

R R

CERTIFIED FINAL

R E

N O

V A

T E

R E

S E

A R

C H

F A

C

IL

IT

Y

F O

R H

Y P

E R

S O

N

IC

S L

A B

F

/2

P R

O J E

C T

Z

H T

V

SCALE: 1/4" = 1'-0"

A1

PH1 PARTIAL FIRST FLOOR PLAN - NEW WORK

0' 4' 8' 16'

SCALE: 1/8" = 1'-0"

C8

PH1 RM 049 - NEW WORK

SCALE: 1/8" = 1'-0"

E8

PH1 RM 136 - NEW WORK

A

M E

N D

M E

N T

/2

/2

W

2Q R

R

_P la ns -0

REF. REF.

K J H

A-423

A5

A-423F7 F5

A-423 D7

B5

A-423D3

F1

A2

A1

A-424B1

A-424

A4

A3

A-424

D4

D1

B4

A-424 A1

F3

F5

A-424F1

D5

B3

B2

B1

092104

109110

005016017

ME

163 164 166

UNDER

CTR

034 038053 055088

A-423F3

023 BELOW CTR

ITEM #87 EXHAUST

FUME HOOD ABOVE

J H

RELOCATED FROM LAB 199:

CABINETS AND COUNTERTOP ONLY,

NO UTILITIES NEEDED. CAN BE

POSITIONED AFTER STORAGE NEED

IS COMPLETED

(8) STORAGE LOCKERS RM 188, 191, 193 AND 197

EXISTING WORKSTATIONS IN

THIS AREA REMAIN HOWEVER

SHIFTING THEM TO CREATE

STORAGE SPACE IS

ACCEPTABLE

STORAGE RACKS FROM

RM 188 AND 193

PHASE 1

PHASE 2

BUILDING 655

ROOMS

155A & B

ROOM

ROOM

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

PLAN NORTH

KEY PLAN

Q-412

E N

L A

R G

E D

P H

A S

E

E Q

U

IP

M E

N T

P L

A N

N

E W

W O

R K

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

O H

IO

L

O U

IS

V

IL

L

E D

IS

T

R

IC

T L

O U

IS

V

IL

L

E K

E N

T U

C K

Y

R C

U R

R A

N

B C

H E

R R

Y

S K

IM

B

A L L

J S

W E

E N

E Y

J U

N E

W Q

R R

CERTIFIED FINAL

R E

N O

V A

T E

R E

S E

A R

C H

F A

C

IL

IT

Y

F O

R H

Y P

E R

S O

N

IC

S L

A B

F

/2

P R

O J E

C T

Z

H T

V

SCALE: 1/4" = 1'-0"

A1

PH2 PARTIAL FIRST FLOOR PLAN - NEW WORK

0' 4' 8' 16'

A

M E

N D

M E

N T

/2

/2

SCALE: 1/8" = 1'-0"

C8

PH2 RM 136 - NEW WORK

W

2Q R

R

_P la ns -0

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

Q-601

L A

B E

Q U

IP

M

E N

T S

C H

E D

U L

E

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

O H

IO

L

O U

IS

V

IL

L

E D

IS

T

R

IC

T L

O U

IS

V

IL

L

E K

E N

T U

C K

Y

R C

U R

R A

N

B C

H E

R R

Y

S K

IM

B

A L L

J S

W E

E N

E Y

J U

N E

W Q

R R

CERTIFIED FINAL

R E

N O

V A

T E

R E

S E

A R

C H

F A

C

IL

IT

Y

F O

R H

Y P

E R

S O

N

IC

S L

A B

F

/2

P R

O J E

C T

Z

H T

V

LAB EQUIPMENT SCHEDULE

ITEM # COMMON NAME DESCRIPTION

CURRENT

LOCATION

TEMP

LOCATION

(DURING

CNST PI)

TEMP

LOCATION

(DURING

CNST PII)

NEW

LOCATION

WIDTH (IN)

DEPTH

(IN)

HEIGHT

(IN)

ELECTRICAL WATER GAS COMM HVAC NOTES GFGI * GFCI ** CFCI ***

NOTE(1)

001 NOT USED ---- ---- ----

002 STORAGE LOCKER #10 136.0 136.0 136.0 136.0 ---- ---- ---- ---- ---- X

003 NOT USED ---- ---- ---- ---- ----

004 NOT USED ---- ---- ---- ---- ----

005 BALANCE (METTLER)

METTLER ANALYTICAL

BALANCE AE 240

183.0 183.0 193.0 183.0 16.0 16.0 110V OUTLET ---- ---- ---- ---- MARBLE TABLE X

006 BATH CIRCULATOR NESLAB 183.0 183.0 193.0 183.0 110V OUTLET ---- ---- ---- ---- X

007 NOT USED

008 NOT USED

009 NOT USED ----

DEIONIZED WATER

SYSTEM

BARNSTEAD/NANO

PURE WATER SYSTEM

M/N D4744

183.0 183.0 136.0 183.0 110V OUTLET

DISTILLED WATER

IN LOCAL JUGS

---- ---- ---- X

011 FLAMMABLE CABINET #1 ---- ---- ---- 183.0 43.0 18.0 69.0 ---- ---- ---- ---- ---- REMOVE/REPLACE WITH NEW X

012 FLAMMABLE CABINET #2 ---- ---- ---- 199.0 43.0 18.0 69.0 ---- ---- ---- ---- ---- REMOVE/REPLACE WITH NEW X

013 FUME HOOD-11 8' FUME HOOD ---- ---- ---- 183.0

USE EXISTING

POWER

DOMESTIC WATER

VACUUM

(HOUSE),

COMPRESSED

AIR (HOUSE),

ARGON

(BOTTLED)

REPLACE

EXHAUST FAN

NEW ACID WASTE AND ACID VENT X

014 FUME HOOD-8 6' FUME HOOD ---- ---- ---- 183.0

USE EXISTING

POWER

DOMESTIC WATER

VACUUM

(HOUSE),

COMPRESSED

AIR (HOUSE)

REPLACE

EXHAUST FAN

NEW ACID WASTE AND ACID VENT X

015 GLOVE BOX #1 BRAUN M/N MB-10 183.0 183.0 193.0 199.0 36.0 108.0

110V, 20AMP

OUTLET

ARGON 100LPM

REGULATED TO

35-70 PSIG (2.5-5.0

KG/CM²). (<5PPM

IMPURITY TOTAL).

10%HYDROGEN/A

RGON MIX

ACCESSORY: 1-VACUUM PUMP,

110V OUTLET

X

016 PAN BALANCE (O'HAUS)

VOYAGER PRO

BALANCE NP2102CN

183.0 183.0 193.0 183.0 16.0 16.0 110V OUTLET ---- ---- ---- ---- X

PAN BALANCE

(SARTORIUS)

SARTORIUS MODEL

3826MP8-1 PAN TOP

BALANCE

183.0 183.0 193.0 183.0 16.0 16.0 110V OUTLET ---- ---- ---- ---- X

018 ROTO BUCHI 183.0 183.0 193.0 183.0 22.0 16.0 110V OUTLET ---- HOUSE VACUUM ---- ---- CONNECTS TO NESLAB X

019 NOT USED

020 NOT USED

021 NOT USED ----

022 FRIDGE #1 SMALL 185.0 185.0 CORRIDOR 199.0 32.0 28.0 110V OUTLET ---- ---- ---- ---- X

023 FRIDGE #2 SMALL 185.0 185.0 CORRIDOR 195.0 32.0 28.0 110V OUTLET ---- ---- ---- ---- X

024 FRIDGE #3 LARGE 185.0 185.0 193.0 185.0 32.0 32.0 110V OUTLET ---- ---- ---- ---- X

025 NOT USED

026 FUME HOOD 8' FUME HOOD ---- ---- ---- 185.0

USE EXISTING

POWER

DOMESTIC WATER

VACUUM

(HOUSE),

COMPRESSED

AIR (HOUSE),

ARGON

(BOTTLED)

REPLACE

EXHAUST FAN

NEW ACID WASTE AND ACID VENT X

GRAVITY CONVECTION

OVEN #1

YAMATO DUS-602

WHITE

185.0 185.0 191.0 185.0 28.0 24.0 30.0 110V OUTLET ---- ---- ---- ---- X

GRAVITY CONVECTION

OVEN #2

YAMATO DKN400

DUS-400 WHITE

185.0 185.0 193.0 185.0 28.0 24.0 30.0 110V OUTLET ---- ---- ---- ---- X

GRAVITY CONVECTION

OVEN #3

YAMATO DVS400 185.0 185.0 193.0 195.0 22.0 24.0 31.0 110V OUTLET ---- ---- ---- ---- X

030 MIXER KITCHENAID 185.0 185.0 193.0 185.0 24.0 16.0 110V OUTLET ---- ---- ---- ---- X

031 NOT USED ---- ---- ---- ----

032 NOT USED ---- ---- ---- ----

033 STORAGE LOCKER #3 185.0 185.0 136.0 136.0 36.0 24.0 ---- ---- ---- ---- ---- X

034 ULTRASONIC CLEANER BRANSON 5510 185.0 185.0 193.0 185.0 16.0 16.0 110V OUTLET ---- ---- ---- ---- X

035 BALL MILL #1

ROLLER TO PUT BALL

MILL MIXING U.S.

STONEWARE

193.0 197.0 193.0 197.0 12.0 24.0 110V OUTLET ---- ---- ---- ---- X

036 BALL MILL #2

ROLLER TO PUT BALL

MILL MIXING U.S.

STONEWARE

193.0 197.0 193.0 197.0 12.0 24.0 110V OUTLET ---- ---- ---- ---- X

037 CARVER PRESS #1 193.0 199.0 193.0 193.0 25.0 24.0 ---- ---- ---- ---- ---- X

038 CARVER PRESS #2 193.0 136.0 136.0 195.0 32.0 24.0 110V OUTLET ---- ---- ---- ---- X

039 CARVER PRESS #3 193.0 136.0 136.0 185.0 32.0 24.0 ---- ---- ---- ---- ---- X

040 NOT USED

041 NOT USED

042 NOT USED

043 NOT USED

044 NOT USED

045 FIBER COATER RIG

COATING RIG WITH 1"

VERTICAL TUBE

FURNACE

193.0 199.0 191.0 188/191 72.0 36.0

120V, 20AMP

OUTLET; 110V

OUTLET X3

---- ---- ---- HOOD X

FIBER COATER RIG

FILAMENT WINDER

THE BLUE RIG WITH

FURNACE AND

WINDER DRUMS OR

PLATES

193.0 199.0 191.0 188/191 52.0 48.0 110V OUTLET X3 ---- ---- ---- ---- X

047 FLAMMABLE CABINET #3 ---- ---- ---- 199.0 43.0 18.0 69.0 ---- ---- ---- ---- ---- REMOVE/REPLACE WITH NEW X

048 FLAMMABLE CABINET #4 ---- ---- ---- 185.0 43.0 18.0 69.0 ---- ---- ---- ---- ---- REMOVE/REPLACE WITH NEW X

049 FUME HOOD 5' FUME HOOD ---- ---- ---- 193.0

USE EXISTING

POWER

DOMESTIC WATER

VACUUM

(HOUSE),

COMPRESSED

AIR (HOUSE)

REPLACE

EXHAUST FAN

NEW ACID WASTE AND ACID VENT X

050 FUME HOOD WALK-IN 193.0 193.0 193.0 193.0

USE EXISTING

POWER

USE EXISTING USE EXISTING ----

REPLACE

EXHAUST FAN

EXISTING TO REMAIN

051 NOT USED

052 GLOVE BOX #2 BRAUN M/N MB-10 193.0 CORRIDOR CORRIDOR 199.0 144.0 36.0

110V, 20AMP

OUTLET

ARGON 100LPM

REGULATED TO

35-70 PSIG (2.5-5.0

KG/CM²). (<5PPM

IMPURITY TOTAL).

10%HYDROGEN/A

RGON MIX

ACCESSORY: 1-VACUUM PUMP,

110V OUTLET

X

HIGH PRESSURE

REACTION VESSEL

FIKE D3141-2 193.0 136.0 136.0 185.0 110V OUTLET ---- ---- ---- ---- X

054 HUMIDITY OVEN 193.0 136.0 136.0 193.0 28.0 20.0 110V OUTLET

DE-IONIZED

WATER FROM

LOCAL JUG;

DRAIN TO BUCKET

HOUSE

COMPRESSED

AIR

---- ---- X

055 LAMINATOR CHEMINSTRUMENTS 193.0 136.0 136.0 197.0 36.0 12.0 110V OUTLET ----

HOUSE

COMPRESSED

AIR

---- ---- X

* GFGI - GOVERNMENT FURNISHED, GOVERNMENT INSTALLED

** GFCI - GOVERNMENT FURNISHED, CONTRACTOR INSTALLED

*** CFCI - CONTRACTOR FURNISHED, CONTRACTOR INSTALLED

NOTES:

(1) GFGI EQUIPMENT IS EXISTING. GOVERNMENT WILL BE RESPONSIBLE TO MOVE THE EQUIPMENT TO STORAGE PRIOR TO COMMENCEMENT OF CONSTRUCTION. UPON COMPLETION OF CONSTRUCTION FOR EACH PHASE THE GOVERNMENT WILL RELOCATE GFGI EQUIPMENT FROM STORAGE TO ITS FINAL LOCATION WITHIN THE LABORATORIES. NO WORK FOR THESE ITEMS IS REQUIRED BY THE CONTRACTOR AS FAR AS EQUIPMENT IS CONCERNED. CONTRACTOR IS STILL RESPONSIBLE TO PROVIDE ALL UTILITIES AND SPACE FOR THE EQUIPMENT.

(2) REFER TO Q-700 SERIES DRAWINGS FOR PHOTOS OF EXISTING EQUIPMENT.

(3) GFCI EQUIPMENT IS EXISTING EQUIPMENT THAT IS OWNED OR PROVIDED BY THE GOVERNMENT BUT CONTRACTOR SHALL REMOVE AND STORE TEMPORARILY. WHEN NEW WORK IS COMPLETED PER EACH PHASE CONTRACTOR IS RESPONSIBLE TO LOCATE EQUIPMENT TO ITS NEW LOCATION AND MAKE HOOK-UPS TO NEW

UTILITIES AS NEEDED.

A

M E

N D

M E

N T

/2

/2

W

2Q R

R

_P la ns -0

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

Q-602

L A

B E

Q U

IP

M

E N

T S

C H

E D

U L

E

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

O H

IO

L

O U

IS

V

IL

L

E D

IS

T

R

IC

T L

O U

IS

V

IL

L

E K

E N

T U

C K

Y

R C

U R

R A

N

B C

H E

R R

Y

S K

IM

B

A L L

J S

W E

E N

E Y

J U

N E

W Q

R R

CERTIFIED FINAL

R E

N O

V A

T E

R E

S E

A R

C H

F A

C

IL

IT

Y

F O

R H

Y P

E R

S O

N

IC

S L

A B

F

/2

P R

O J E

C T

Z

H T

V

LAB EQUIPMENT SCHEDULE

ITEM # COMMON NAME DESCRIPTION

CURRENT

LOCATION

TEMP

LOCATION

(DURING

CNST PI)

TEMP

LOCATION

(DURING

CNST PII)

NEW

LOCATION

WIDTH (IN)

DEPTH

(IN)

HEIGHT

(IN)

ELECTRICAL WATER GAS COMM HVAC NOTES GFGI * GFCI ** CFCI ***

NOTE

(1)

056 LATHE MICROLUX 193.0 197.0 193.0 193.0 38.0 24.0 110V OUTLET ---- ---- ---- ---- X

057 MINI SPRAY DRYER BUCHI B-290 193.0 CORRIDOR 193.0 193.0 20.0 26.0 250V 20A ---- ---- ---- ---- X

058 SAW PSC0150 193.0 197.0 193.0 193.0 24.0 12.0 110V OUTLET ---- ---- ---- ---- X

059 SPIN COATER

LAURELL MODEL

WS-0400 BZ-6NPP/LITE

(REV. MS)

193.0 136.0 136.0 193.0

95-240VAC

OUTLET

---- <= 60 PSI ---- ---- X

060 STORAGE LOCKER #4 193.0 136.0 136.0 136.0 36.0 24.0 ---- ---- ---- ---- ---- X

061 STORAGE LOCKER #5 193.0 136.0 136.0 136.0 36.0 24.0 ---- ---- ---- ---- ---- X

062 STORAGE RACK #1 193.0 136.0 136.0 136.0 48.0 24.0 ---- ---- ---- ---- ---- X

063 SYRINGE PUMP #1

TELEDYNE D-SERIES

100DM SYRINGE

PUMP

193.0 185.0 193.0 195.0 117V 1.5AMP 60HZ ---- HOUSE VACUUM ---- ---- X

064 SYRINGE PUMP #2

TELEDYNE D-SERIES

100DM SYRINGE

PUMP

193.0 136.0 136.0 195.0 117V 1.5AMP 60HZ ---- HOUSE VACUUM ---- ---- X

065 SYRINGE PUMP #3

TELEDYNE D-SERIES

100DM SYRINGE

PUMP

193.0 136.0 136.0 195.0 117V 1.5AMP 60HZ ---- HOUSE VACUUM ---- ---- X

066 TABLE 193.0 136.0 136.0 136.0 52.0 37.0 ---- ---- ---- ---- ---- X

067 TAPE CASTER

EPH ENGINEERING

ASSOCIATES

193.0 N/A X

068 VACUUM OVEN #1 COLE-PARMER 193.0 136.0 136.0 193.0 20.0 24.0 110V OUTLET ---- HOUSE VACUUM ---- ---- X

069 VACUUM OVEN #14 JERO TECH #14 193.0 199.0 199.0 193.0 30.0 24.0

120VAC 60HZ 10.0

AMP OUTLET

---- HOUSE VACUUM

LAPTOP

COMPUTER

---- X

070 VACUUM OVEN #18 JERO TECH #18 193.0 199.0 199.0 193.0 30.0 24.0

120VAC 60HZ 10.0

AMP OUTLET

---- HOUSE VACUUM

DESKTOP

COMPUTER

---- X

071 VACUUM OVEN #2 COLE-PARMER 193.0 136.0 136.0 193.0 22.0 24.0 110V OUTLET ---- HOUSE VACUUM ---- ---- X

072 NOT USED

073 NOT USED

074 NOT USED

075 DESK QTY 4 195.0 136.0 136.0 136.0 ---- ---- ---- ---- ---- LOCATED ALONG BACK WALL X

076 FIBER POLISH 195.0 136.0 136.0 136.0 24.0 24.0 110V OUTLET ----

100 PSI HOUSE

COMPRESSED AIR

---- ---- X

077 FIBER PUSH OUT TESTER 195.0 136.0 136.0 136.0 42.0 36.0

110V + POWER

STRIP 6+ UNIT

PLUG

100 PSI HOUSE

COMPRESSED AIR

---- ---- X

078 MTS SYNERGIE 400

E/M MECHANIC TEST

FRAME

195.0 136.0 136.0 136.0 48.0 24.0 110V OUTLET ---- ---- ---- ---- X

079 USCOPE 195.0 136.0 136.0 136.0 24.0 24.0 110V OUTLET ---- ----

DESKTOP

COMPUTER

---- X

080 USCOPE 195.0 136.0 136.0 136.0 24.0 24.0 110V OUTLET ---- ----

DESKTOP

COMPUTER

---- X

081 AUTOCLAVE

ASC PROCESS

SYSTEMS

197.0 CORRIDOR CORRIDOR 197.0 480V/60HZ 42 AMP

1/2" 45 DEG F

CHWS/CHWR

100 PSI HOUSE

AIR - HOUSE

NITROGEN + 4

TANKS - HOUSE

VACUUM

DESKTOP

COMPUTER

3" HOT VENT

TO OUT SIDE

X

082 NOT USED

083 NOT USED

084 NOT USED

085 CUT TABLE

GUILLOTINE TYPE

CUT

---- ---- ---- 197.0 34.0 38.0 30.0 ---- ---- ---- ---- ---- REMOVE/REPLACE WITH NEW X

086 FUME HOOD 8' FUME HOOD ---- ---- ---- 197.0 USE EXISTING DOMESTIC WATER

VACUUM (HOUSE),

COMPRESSED AIR

(HOUSE)

---- ---- NEW ACID WASTE AND ACID VENT X

087 FUME VENT ---- ---- ---- 197.0 USE EXISTING ---- ---- ---- ---- REMOVE/REPLACE WITH NEW X

088 IMPULSE AUTOSEALER 197.0 197.0 136.0 197.0 24.0 12.0 110V OUTLET ---- ---- ---- ---- X

089 ROLL RACK 197.0 197.0 136.0 197.0 72.0 16.0 ---- ---- ---- ---- ---- X

090 STORAGE LOCKER #1 197.0 197.0 136.0 136.0 36.0 24.0 ---- ---- ---- ---- ---- X

091 STORAGE LOCKER #2 197.0 197.0 136.0 136.0 36.0 24.0 ---- ---- ---- ---- ---- X

092 THINKY MIXER #1

PLANETARY VACUUM

MIXER

197.0 197.0 193.0 199.0 24.0 24.0 110V OUTLET ---- ---- ---- ----

ACCESSORY: 100V

TRANSFORMER (SMALL)

X

093 THINKY MIXER #2

PLANETARY VACUUM

MIXER YAG

197.0 197.0 193.0 195.0 24.0 24.0 110V OUTLET ---- ---- ---- ----

ACCESSORY: 100V

TRANSFORMER (SMALL)

X

094 ASIGA 199.0 199.0 136.0 199.0 12.0 12.0 110V OUTLET ---- ----

DESKTOP

COMPUTER

---- X

095 NOT USED

096 NOT USED

097 NOT USED

098 NOT USED

099 NOT USED

100 CENTRIFUGE

SORVALL S/N 3407129

M/N T-21

199.0 199.0 193.0 195.0 36.0 28.0

208V, SINGLE

PHASE, 20A

OUTLET

---- ---- ---- ---- X

101 D7 DUPLICATOR 7 199.0 199.0 136.0 199.0 12.0 12.0 110V OUTLET ---- ---- ---- ---- X

102 DESICCATOR RACK 199.0 199.0 136.0 199.0 54.0 16.0 ---- ---- HOUSE VACUUM ---- ----

ONE HOUSE VACUUM DROP TO 6

DRY BOXES; PROVIDE NEW LAB

SHELVING UNIT FOR THESE

X

103 FISHER GRINDER 199.0 199.0 136.0 199.0 110V OUTLET ---- ---- ---- ---- X

104 FISHER OVEN

FISHER ISOTEMP

OVEN

199.0 199.0 136.0 199.0 24.0 24.0 110V OUTLET ---- ---- ---- ---- X

105 FREEZER 199.0 199.0 193.0 185.0 32.0 30.0 110V OUTLET ---- ---- ---- ---- X

106 HJ LASER 3D LASER PRINTER 199.0 199.0 136.0 185.0 24.0 24.0 110V OUTLET ---- ---- ---- ---- X

107 X 2 (2) HYREL HYREL SYSTEM 30M 199.0 199.0 136.0 199.0 42.0 16.0 110V OUTLET ---- ---- ---- ----

ACCESSORIES: COMPUTER

PARTS

X

108 PARTICLE SIZE ANALYZER

LASER DIFFRACTION

LS 13 320

199.0 199.0 136.0 199.0 42.0 16.0 110V OUTLET

DISTILLED WATER

FROM LOCAL JUG.

DRAIN TO LOCAL

JUG JUST UNDER

COUNTER

---- ---- ---- X

109 PYCNOMETER ACCUPYC 1330 199.0 199.0 136.0 199.0 12.0 12.0 110V OUTLET ---- HELIUM (TANK) PRINTER ---- X

110 RHEO

BROOKFIELD

RHEOMETER

199.0 199.0 136.0 199.0 22.0 16.0 110V OUTLET ---- ----

LAPTOP

COMPUTER

---- X

* GFGI - GOVERNMENT FURNISHED, GOVERNMENT INSTALLED

** GFCI - GOVERNMENT FURNISHED, CONTRACTOR INSTALLED

*** CFCI - CONTRACTOR FURNISHED, CONTRACTOR INSTALLED

NOTES:

(1) GFGI EQUIPMENT IS EXISTING. GOVERNMENT WILL BE RESPONSIBLE TO MOVE THE EQUIPMENT TO STORAGE PRIOR TO COMMENCEMENT OF CONSTRUCTION. UPON COMPLETION OF CONSTRUCTION FOR EACH PHASE THE GOVERNMENT WILL RELOCATE GFGI EQUIPMENT FROM STORAGE TO ITS FINAL LOCATION WITHIN THE LABORATORIES. NO WORK FOR THESE ITEMS IS REQUIRED BY THE CONTRACTOR AS FAR AS EQUIPMENT IS CONCERNED. CONTRACTOR IS TILL RESPONSIBLE TO PROVIDE ALL UTILITIES AND SPACE FOR THE EQUIPMENT.

(2) REFER TO Q-700 SERIES DRAWINGS FOR PHOTOS OF EXISTING EQUIPMENT.

(3) GFCI EQUIPMENT IS EXISTING EQUIPMENT THAT IS OWNED OR PROVIDED BY THE GOVERNMENT BUT CONTRACTOR SHALL REMOVE AND STORE TEMPORARILY. WHEN NEW WORK IS COMPLETED PER EACH PHASE CONTRACTOR IS RESPONSIBLE TO LOCATE EQUIPMENT TO ITS NEW LOCATION AND MAKE HOOK-UPS TO NEW

UTILITIES AS NEEDED.

A

M E

N D

M E

N T

/2

/2

W

2Q R

R

_P la ns -0

A-421 - INTERIOR ELEVATIONS
A-601.pdf
A-601 - DOOR SCHEDULE AND DETAILS
FD-101.pdf
01180309_FIRE PROT_BLDG 655 LAB_R20
FD101 - FIRE PROTECTION DEMO
FX-101.pdf
01180309_FIRE PROT_BLDG 655 LAB_R20
FX101 - FIRE SPRINKLER PLAN
I-601.pdf
I-601 - INTERIOR SCHEDULES
Q-401.pdf
Q-401 - ENLARGED PHASE 1 EQUIPMENT PLAN - EXISTING
Q-402.pdf
Q-402 - ENLARGED PHASE 2 EQUIPMENT PLAN - EXISTING
Q-411.pdf
Q-411 - ENLARGED PHASE 1 EQUIPMENT PLAN - NEW WORK
Q-412.pdf
Q-412 - ENLARGED PHASE 2 EQUIPMENT PLAN - NEW WORK
Q-601.pdf
Q-601 - LAB EQUIPMENT SCHEDULE
Q-602.pdf
Q-602 - LAB EQUIPMENT SCHEDULE

Untitled

File details come from the government source that posted it. Updated .