W912QR21R0015_Plans-0004.pdf

PDF 708 KB Posted

Attached to
Ft. Campbell Vehicle Maintenance Shop
Solicitation number
W912QR21R0015
Issued by

About this file

This document package includes plans and schedules for a vehicle maintenance shop project and the related federal contract opportunity on FedBizOpps.

The plans detail the layout and specifications for compressed air, plumbing, and fluid dispensing systems for the proposed vehicle maintenance shop to be constructed at Fort Campbell, Kentucky. The schedules provide additional information on fixtures, equipment, and components including air compressors, pumps, tanks, and related items.

The federal contract opportunity on FedBizOpps is a draft pre-solicitation notice for construction of the vehicle maintenance shop with an estimated cost between $25-100 million. Responses will be due 30 days after release of the formal solicitation anticipated around April 16, 2021. The solicitation number is W912QR21R0015 and is being conducted by the Department of the Army Corps of Engineers Louisville District. The NAICS code is 236220 for commercial and institutional building construction with a size standard of $39.5 million. This will be a full and open competition following HUBZone price evaluation preferences.

View the file

Other files

Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

MO

TR

GR

AF

GO

A

MO

AAAA

GR

TR

GR

GOAF

MOTOR

OIL

TRANS-

MISSION

FLUID

CHASSIS

GREASE

GEAR

OIL

ANTI-

FREEZE

PUMP LIFT

LUBRICATION

PUMP (TYP)

AIR MAIN

1"

SEE PLANS FOR

PIPE SIZES

1"1"

NOTE 1

(TYP)

NOTES:

1. PROVIDE COMPRESSED AIR

LINE WITH FILTER AND

LUBRICATOR.

LOCATE FILTER AND

LUBRICATOR BELOW 6'.

AIR COMPRESSOR PIPING DIAGRAM NOTES

AIR COMPRESSOR

BALL VALVE

FLEXIBLE CONNECTOR

UNION

SAFETY RELIEF VALVE -

SET @ 175 PSI

AUTOMATIC DRAIN VALVE

DRAIN VALVE

CHECK VALVE

PRESSURE GAUGE

(0-240 PSI RANGE)

DRAIN VALVE

FLOOR DRAIN

AIR-COOLED REFRIGERATED

AIR DRYER

NOT USED

DRAIN VALVEMAINLINE FILTER DRAIN VALVE

STRAINER

DRAIN VALVEPRESSURE REGULATING VALVE

NOT USED

NORMALLY CLOSED (GLOBE) BYPASS VALVE

14 15

CA

SEE REFRIGERATED DRYER DETAIL

EQUIPMENT PAD SEE

STRUCTURAL PLATES

FOR SIZES

PROVIDE VIBRATION ISOLATOR PER

COMPRESSOR MANUFACTURER'S

RECOMMENDATION

NOT USED

DRY RECEIVER TANK

PACKAGED AIR

COMPRESSOR UNIT

CONTAINS WET RECEIVER

TANK, AFTERCOOLER,

FILTERS, WATER

SEPERATOR

NEEDLE

VALVE

PIPING FROM POL DIST

RM. SEE PLANS FOR

SIZES

BALL VALVE (TYP OF FOUR)

ANTIFREEZE GEAR

OIL

MOTOR OIL TRANS GREASE

REEL HOUSING

ADJUSTABLE STOP

CHASSIS GREASE

GEAR OIL

W/PRESET METER

TRANSMISSION FLUID

W/PRESET METER

MOTOR OIL

W/PRESET

METER

ANTIFREEZE

W/PRESET METER

NOTES:

1. ALL HOSES SHALL HAVE AN ADJUSTABLE STOP TO ADJUST HEIGHT. HEIGHT SHALL NOT BE ANY

HIGHER THAN 6 FT AFF.

2. PROVIDE WAHSBLE BACKSPLASH ON THE WALL BELOW HOSE REEL ENCLOSURE TO THE FLOOR.

BACKSPLASH SHALL EXTEND 2 FEET ON EITHER SIDE OF THE STATIONS LOCATED IN THE VEHICLE

CORRIDOR.

3. MOUNT BOTTOM OF ENCLOSURE AT 8 FT AFF. MOUNT IN ACCORDANCE WITH MANUFACTURER'S

GUIDELINES. COORDINATE LOADS AND CONNECTIONS WITH THE BUILDING FABRICATOR.

PRESSURE REGULATING VALVE,

190 CFM, 0-175 PSIG RANGE,

SET AT 125 PSIG

1" FILTER - 190 CFM

1 PSIG MAX

PRESSURE DROP

BYPASS VALVE,

(NORMALLY CLOSED)

1" FILTER - 190 CFM

1 PSIG MAX

PRESSURE DROP

FROM AIR COMPRESSOR TO COMPRESSED AIR SYSTEM

FINISHED FLOOR

EQUIPMENT PAD

FLEXIBLE CONNECTION

SOLENOID VALVE

OPEN-CLOSE WITH

DRIVER ON-OFF

SWITCH

FLEXIBLE CONNECTION

AUTOMATIC TRAP

80 GPH AT 100 PSIG

DRAIN VALVE

3/4" CONDENSATE DRAIN

RUN TO FLOOR DRAIN

6 F

EE

T

4 FE

ET

NOTE:

1. COMBINATION FILTER, PRV, LUBRICATOR & PRESSURE GAUGE.

2. COMPRESSED AIR OUTLETS SERVING THE CONSOLIDATED

BENCH SHALL NOT HAVE LUBRICATORS.

3. COORDINATE WITH USER ON FINAL FEMALE DISCONNECT TYPES

AND FINAL LOCATIONS.

MAKE BRANCH CONNECTION

AT TOP OF MAIN

COMPRESSED AIR MAIN

SUPPORT AS REQUIRED

FEMALE QUICK DISCONNECT

FILTER*

PRV*

PRESSURE GAUGE*

LUBRICATOR*

FEMALE QUICK DISCONNECT

BALL VALVE

CONDENSATE TRAP

FLOOR

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENDKTD\Desktop\Kate Desktop\Campbell\FY19PN64296-MECH_R18_TW Current.rvt

5/24/2021 4:30:16 PM

D

EC

EM

BE

R

W

2Q R

-2 1-

R -0

K.

D

IX

O

N

K.

D

IX

O

N

J.

S

TE

IN

FY

PN

2T

EM

F_

P-

4.

dg n

4-

-0

PL504

PL

U

M

BI

N G

D

ET

AI

LS

IV

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

D

R . M

AR

TI

N L

U

TH

ER

K

IN

G

J R

P L.

LO

U

IS

VI

LL

E, K Y

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T C

AM

PB

EL

L, K

EN

TU

C

KY

VE

H

IC

LE

M

AI

N

TE

N

AN

C

E

SH

O P

PN

P2

:3

VO

LU

M E

-B

U

IL

D

IN

G

R . Y

EA

R

W O

O D

READY TO ADVERTISE (RTA)

BULK DISPENSING SCHEMATIC3

AIR COMPRESSOR (AC-1&2)1

HOSE REEL STATION2 REFRIGERATED DRYER PIPING5

COMPRESSED AIR OUTLET4

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

M

AY

W

2Q R

R

-0

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENDKTD\Desktop\Kate Desktop\Campbell\FY19PN64296-MECH_R18_TW Current.rvt

5/24/2021 4:30:20 PM

D

EC

EM

BE

R

W

2Q R

-2 1-

R -0

K.

D

IX

O

N

K.

D

IX

O

N

J.

S

TE

IN

4-

-0

PL601

PL

U

M

BI

N G

S C

H

ED

U

LE

S

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

D

R . M

AR

TI

N L

U

TH

ER

K

IN

G

J R

P L.

LO

U

IS

VI

LL

E, K Y

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

SA

VA

N N

AH

, G

A

FO

R

T C

AM

PB

EL

L, K

EN

TU

C

KY

VE

H

IC

LE

M

AI

N

TE

N

AN

C

E

SH

O P

PN

P2

:3

VO

LU

M E

-B

U

IL

D

IN

G

R . Y

EA

R

W O

O D

READY TO ADVERTISE (RTA)

PLUMBING FIXTURE SCHEDULE

MARK DESCRIPTION C.W. (IN) H.W. (IN)

WASTE

(IN) VENT (IN) NOTES

FD-A 3" FLOOR DRAIN 3" 1 1/2"

FD-B 4" FLOOR DRAIN 4" 2"

HB FREEZE PROOF HOSE BIBB 3/4"

P-1 WATER CLOSET 1" 4" 2" FLUSH VALVE, DUAL FLUSH

P-1A ADA WATER CLOSET 1" 4" 2" FLUSH VALVE, DUAL FLUSH

P-3A ADA URINAL 3/4" 2" 1 1/4" FLUSH VALVE

P-4 LAVATORY 1/2" 1/2" 1 1/2" 1 1/4"

P-4A ADA LAVATORY 1/2" 1/2" 1 1/2" 1 1/4"

P-7 DOUBLE COMPARTMENT SINK 1/2" 1/2" 1 1/2" 1 1/4" STAINLESS STEEL, GARBAGE DISPOSAL

P-9 WASH FOUNTAIN 1/2" 1/2" 1 1/2" 1 1/4" ANTI-SCALD, PRESSURE BALANCED TYPE

P-10A ADA SHOWER 1/2" 1/2" 2" 1 1/4" ANTI-SCALD, PRESSURE BALANCED TYPE

P-11 WATER COOLER 1/2" 1 1/2" 1 1/4" PROVIDE WITH BOTTLE FILLER

P-11A ADA WATER COOLER 1/2" 1 1/2" 1 1/4" PROVIDE WITH BOTTLE FILLER

P-12 MOP SINK 1/2" 1/2" 3" 1 1/2"

P-13 EMERGENCY EYEWASH/SHOWER 1 1/4" 1 1/4"

P-16 ICE MAKER CONNECTION 1/2" MOUNT 24" AFF

POL FLUID DISTRIBUTION PUMP SCHEDULE

MARK SERVICE

TYPE

MOUNTING

MINIMUM FLUID

PRESSURE RATIO

AIR MOTOR EFFECTIVE

DIAMETER (IN)

MINIMUM FLUID

FLOW (GPM)

APPROX AIR

CONSUMPTION

(SCFM)

AIR

INLET NOTES

AFP-1 ANTIFREEZE DRUM 5:1 4.25 6.8 67 1/2" PROVIDE WITH 55 GALLON DRUM

ATFP-1 TRANSMISSION WALL 5:1 4.25 4.1 67 1/2" PROVIDE WITH 275 GALLON DRUM

GOP-1 GEAR OIL WALL 5:1 4.25 4.1 67 1/2" PROVIDE WITH 275 GALLON DRUM

GRP-1 GREASE WALL 50:1 4.25 0.33 67 3/8" PROVIDE WITH 120 LB DRUM

MOP-1 MOTOR OIL WALL 5:1 4.25 4.1 67 1/2" PROVIDE WITH 275 GALLON DRUM

WOP-1 WASTE OIL WALL 1:1 ~ 50 67 1/2" 1" DOUBLE DIAPHRAGM PUMP

WOP-2 WASTE OIL WALL 1:1 ~ 50 67 1/2" 1" DOUBLE DIAPHRAGM PUMP

WOP-3 WASTE OIL WALL 1:1 ~ 50 67 1/2" 1" DOUBLE DIAPHRAGM PUMP

DOMESTIC HOT WATER HEATER AND STORAGE TANK SCHEDULE

MARK LOCATION

MIN

RECOVERY

RATE (GPH)

FUEL SOURCE

INLET WATER

TEMP

OUTLET WATER

TEMP

NET INPUT

(MBTUH)

MINIMUM

EFFICIENCY

STORAGE TANK DATA

(DWST-1 & DWST-2) DIRECT VENT (IN)

NOTESTYPE

STORAGE

CAPACITY

(MIN GAL)

DIMENSIONS

(MAX) FLUE OUTDOOR AIR

DWH-1 MECHANICAL ROOM 720 NATURAL GAS 60 DEG F 140 DEG F 500 90% 300 (EACH) 36" DIA X 92" H 4" 4" 1,2,3,4

AIR COMPRESSOR SCHEDULE

MARK LOCATION TYPE

PRESSURE

MOTOR (HP)

FLOW

(CFM) NOTES

OPERATING

(PSIG)

MAXIMUM

(PSIG)

AC-1 AIR COMPRESSOR ROOM SIMPLEX 125 175 40 130 1,2,3,4

AC-2 AIR COMPRESSOR ROOM SIMPLEX 125 175 40 130 1,2,3,4

REFRIGERATED AIR DRYER SCHEDULE

MARK LOCATION

FLOW

(CFM)

OPERATING

PRESSURE

(PSIG)

DEW

POINT

(DEG F) NOTES

RD-1 AIR COMPRESSOR ROOM 130 125 38 1

RD-2 AIR COMPRESSOR ROOM 130 125 38 1

EXPANSION TANK SCHEDULE - DOMESTIC WATER

MARK TYPE CONFIGURATION SERVICE

MIN TANK

VOLUME

(GAL)

MIN

ACCEPTANCE

VOLUME

(GAL)

TANK

OPERATING

PRESSURE

(PSIG)

DET-1 BLADDER VERTICAL DOMESTIC HOT WATER 34 19.8 70

PUMP SCHEDULE

MARK LOCATION DESCRIPTION TYPE

CAPACITY

(GPM) HEAD NOTES

DHWP-1 MECHANICAL ROOM DOMESTIC WATER PUMP IN-LINE 1

DHWP-2 MECHANCIAL ROOM DOMESTIC WATER PUMP IN-LINE 1

DWBP-1 MECHANICAL ROOM DOMESTIC WATER BOOSTER PUMP PACKAGED DUPLEX 80 33

DWRP-1 MECHANCIAL ROOM DOMESTIC WATER RECIRCULATING PUMP IN-LINE 2.1 16

WSP-1 MAINT PIT SUMP PUMP SUBMERSIBLE 35 15

WSP-2 ELEVATOR PIT SUMP PUMP SUBMERSIBLE 50 15

NOTES:

1. UNIT SHALL BE A COMPLETE PACKAGED ASSEMBLY WITH WET RECEIVER TANK, AFTERCOOLER, FILTERS, AND WATER SEPARATOR

2. FLOW RATE IS BASED ON THE OPERATING SYSTEM PRESSURE

3. PROVIDE ONE 500 GAL RECEIVER FOR BOTH COMPRESSORS

4. COORDINATE WITH END USER ON FINAL FEMALE DISCONNECT TYPES AND FINAL LOCATIONS.

NOTES:

1. CONDENSING TYPE

2. PROVIDE COMPLETE PACKAGED ASSEMBLY COMPLETE WITH HEATER TO TANK RECIRC PUMPS (DHWP-1 AND DHWP-2) SIZED PER MANUFACTURERS REQUIREMENTS

3. MODULATING CAPACITY BURNER WITH 5-TO-1 MINIMUM TURN DOWN RATIO

4. PROVIDE CONDENSATE NEUTRALIZATION KIT

NOTES:

1. SIZED PER DOMESTIC HOT WATER HEATER MANUFACTURERS REQUIREMENTS

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

M

AY

HR-3 THRU 7 REPAIR BAYS X X X X X

HR-2 VEHICLE CORRIDOR X X X X X

HR-1 PIT X X X

MARK LOCATION MO GO GR ATF AF

HOSE REEL SCHEDULE

NOTES:

1. REFRIGERATED DRYER CAN EITHER BE INCLUDED IN THE PACKAGED SYSTEM OR BE SEPERATE.

W

2Q R

R

-0

PL504 PLUMBING DETAILS IV
PL601 PLUMBING SCHEDULES

File details come from the government source that posted it. Updated .