W912QR20R0045Plans_Vol5-0000.pdf

PDF 36 MB Posted

Attached to
Consolidated Mission Complex (CMC), Phase 3 at Warner Robins Air Force Base (AFB), Georgia
Solicitation number
W912QR20R0045
Issued by

About this file

This document provides details on a federal construction contract solicitation. The solicitation is for construction of a Consolidated Mission Complex (CMC), Phase 3 located at Warner Robins Air Force Base in Georgia. The estimated cost of the construction project is between $25 million and $100 million. The solicitation is a Full-and-Open procurement requiring the HUBZone 10% price evaluation in accordance with FAR 19.1307. The NAICS code is 236220 for construction of new commercial and institutional buildings with a size determination of $39.5 million. The solicitation is issued by the Department of the Army Corps of Engineers Engineering District Louisville. Technical inquiries must be submitted through the Bidder Inquiry system on ProjNet by the specified deadline.

View the file

Other files

File Type Posted
W912QR20R0045Plans-0004.pdf PDF
W912QR20R0045Specs-0004.pdf PDF
W912QR20R0045Specs-0003.pdf PDF
W912QR20R0045Plans-0003.pdf PDF
W912QR20R0045-0002.pdf PDF
W912QR20R0045Specs-0001.pdf PDF
W912QR20R0045Plans-0001.pdf PDF
Site Visit Sign-In Sheet.pdf PDF
LRD JA Warner Robins CMC phase 3 - Mech VAV FCU_Redacted.pdf PDF
LRD JA Warner Robins CMC phase 3 - Electrical_Redacted.pdf PDF
LRD JA Warner Robins CMC phase 3 - Structure_Redacted.pdf PDF
LRD JA Warner Robins CMC phase 3 - Mech chillers and boilers_Redacted.pdf PDF
LRD JA Warner Robins CMC phase 3 - FP_Redacted.pdf PDF
LRD JA Warner Robins CMC phase 3 - Mech AHU_Redacted.pdf PDF
LRD JA Warner Robins CMC phase 3 -Plumbing_Redacted.pdf PDF
W912QR20R0045_FF-E_Vol1-0000.pdf PDF
W912QR20R0045_FF-E_Vol2-0000.pdf PDF
LRD JA Warner Robins CMC phase 3 - Mech cond unit dc fan_Redacted.pdf PDF
W912QR20R0045Plans_Vol4-0000.pdf PDF
LRD JA Warner Robins CMC phase 3 - Security_Redacted.pdf PDF
LRD JA Warner Robins CMC phase 3 - Arch_Redacted.pdf PDF
W912QR20R0045Plans_Vol2-0000.pdf PDF
W912QR20R0045Plans_Vol1-0000.pdf PDF
W912QR20R0045Specs_Vol1-0000.pdf PDF
W912QR20R0045Specs_Vol2-0000.pdf PDF
W912QR20R0045Plans_Vol6-0000.pdf PDF
LRD JA Warner Robins CMC phase 3 - Mech ERU_Redacted.pdf PDF
W912QR20R0045Plans_Vol3-0000.pdf PDF
LRD JA Warner Robins CMC phase 3 - communication_Redacted.pdf PDF
W912QR20R0045_SID-0000.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Jacobs Engineering Group Inc.

777 Main Street, Fort Worth, TX 76102 USA

PRIME CONSULTANT

5250 Cherokee Ave., Suite 420, Alexandria, VA 22312-2052 MAIN 703/658-4400 WEB www.woodspeacock.com

CONSULTANTS CONSULTANTS

- VOLUME 5 OF 6

VICINITY MAP

TRUE NORTH

PROJECT

LOCATION

Martin Luther King JR Boulevard

W a rn e r R o b in s S tre e t

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers ®

SOLICITATION NO.:

ISSUE DATE:

JEG Proj. No. D3191901

US Army Corps of Engineers

F Y

A F

R C

C O

N S

O L

ID

A

T E

D M

IS

S

IO

N

C O

M P

L E

X

P H

A S

E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V

S A

R O

N I

F

IL

E N

A M

E

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

CERTIFIED FINAL DESIGN

P R

O J

E C

T N

U M

B E

R

U H

H Z

P

T B

D

G001E

C O

V E

R S

H E

E T

LOUISVILLE DISTRICT

ROBINS AFB, GEORGIA

FY20 AFRC CONSOLIDATED MISSION COMPLEX

- PHASE 3

TBD

31 AUGUST 2020

PN#: UHHZ073005 P2#: 479708

T

R

IC

E

B

G A

R C

IA

C

S U

R L

E S

U H

H Z

G

E

BASE PROPOSAL AND OPTIONS

BASE PROPOSAL INCLUDES COMPLETE FACILITY AND ASSOCIATED SITE IMPROVEMENTS FOR THE AFRC CONSOLIDATED

MISSIONS COMPLEX PHASE 3, THE FOLLOWING OPTIONS ARE INCLUDED:

OPTION 1 CONSTRUCTION OF FINISHED SHELL SPACE - SOUTH (6,000 SF)

OPTION 2 CONSTRUCTION OF FINISHED AUDITORIUM AND SUPPORT SPACE - EAST (8,500SF)

OPTION 3 PARKING LOT NORTHEAST

OPTION 4 PARKING LOT SOUTH

OPTION 5 ELECTRICAL SWITCH

OPTION 6 DISPOSE EXCESS SOIL (5,000 CY)

OPTION 7 ACCESS CONTROL EQUIPMENT

OPTION 8 STORM WATER DRAINAGE REPLACEMENT (CMP) TO DUCK LAKE

OPTION 9 WATER LINE REPLACEMENT ALONG LAKESIDE DRIVE

08/31/2020

B Y

C H

E C

K E

D B

Y

C H

E C

K E

D G

IN

G L

IS

C H

E C

K E

D G

IN

G L

IS

09 September 2020

W912QR20R0045

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A F

R C

C O

N S

O L

ID

A

T E

D M

IS

S

IO

N

C O

M P

L E

X

P H

A S

E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V

S A

R O

N I

F

IL

E N

A M

E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

P R

O J

E C

T N

U M

B E

R

U H

H Z

P

T B

D

G002E

S H

E E

T I

N D

E X

T

R

IC

E

B

G A

R C

IA

C

S U

R L

E S

U H

H Z

G

E

SHEET INDEX

NO NAME

PLUMBING

P-001 GENERAL NOTES AND SYMBOLS

P-100 OVERALL PLUMBING UNDERFLOOR

P-101 PLUMBING FLOOR PLAN - UNDERFLOOR - AREA A

P-102 PLUMBING FLOOR PLAN - UNDERFLOOR - AREA B

P-103 PLUMBING FLOOR PLAN - UNDERFLOOR - AREA C

P-104 PLUMBING FLOOR PLAN - UNDERFLOOR - AREA D

P-105 PLUMBING FLOOR PLAN - UNDERFLOOR - AREA E

P-106 OVERALL PLUMBING UNDERFLOOR - OPTION 1

P-107 PLUMBING FLOOR PLAN - UNDERFLOOR - OPTION 1

P-108 OVERALL PLUMBING UNDERFLOOR - OPTION 2

P-109 PLUMBING FLOOR PLAN - UNDERFLOOR - OPTION 2

P-110 OVERALL PLUMBING - LEVEL 1

P-111 PLUMBING FLOOR PLAN - LEVEL 1 - AREA A

P-112 PLUMBING FLOOR PLAN - LEVEL 1 - AREA B

P-113 PLUMBING FLOOR PLAN - LEVEL 1 - AREA C

P-114 PLUMBING FLOOR PLAN - LEVEL 1 - AREA D

P-115 PLUMBING FLOOR PLAN - LEVEL 1 - AREA E

P-116 OVERALL PLUMBING - LEVEL 1 - OPTION 1

P-117 PLUMBING FLOOR PLAN - LEVEL 1 - OPTION 1

P-118 OVERALL PLUMBING - LEVEL 1 - OPTION 2

P-119 PLUMBING FLOOR PLAN - LEVEL 1 - OPTION 2

P-120 OVERALL PLUMBING PLAN - LEVEL 2

P-122 PARTIAL PLUMBING PLAN - LEVEL 2 - AREA B

P-123 PARTIAL PLUMBING PLAN - LEVEL 2 - AREA C

P-124 PARTIAL PLUMBING PLAN - LEVEL 2 - AREA D

P-125 PARTIAL PLUMBING PLAN - LEVEL 2 - AREA E

P-126 OVERALL PLUMBING PLAN - LEVEL 2 - OPTION 1

P-128 OVERALL PLUMBING PLAN - LEVEL 2 - OPTION 2

P-130 OVERALL ROOF PLAN

P-131 OVERALL ROOF PLAN - OPTION 1

P-132 OVERALL ROOF PLAN - OPTION 2

P-401 ENLARGED MECHANICAL ROOM PLUMBING PLANS

P-402 ENLARGED MECHANICAL ROOM PLUMBING PLANS - OPTION 2

P-403 ENLARGED RESTROOMS PLUMBING PLANS

P-404 ENLARGED RESTROOMS PLUMBING PLANS - OPTION 2

P-405 ENLARGED EAST MECHANICAL ROOM PLUMBING PLANS

P-501 PLUMBING DETAILS

P-502 PLUMBING DETAILS

P-503 PLUMBING DETAILS

P-504 PLUMBING DETAILS

P-601 PLUMBING SCHEDULES

P-701 RISER DIAGRAMS

P-702 RISER DIAGRAMS

P-801 PLUMBING CONTROLS

P-802 PLUMBING CONTROLS

P-803 PLUMBING CONTROLS

FIRE PROTECTION

F-001 GENERAL NOTES AND SYMBOLS

FA111 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 1 - AREA A

FA112 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 1 - AREA B

FA113 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 1 - AREA C

FA114 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 1 - AREA D

FA115 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 1 - AREA E

FA116 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 1 - OPTION 1

FA117 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 1 - OPTION 2

FA122 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 2 - AREA B

FA123 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 2 - AREA C

FA124 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 2 - AREA D

FA125 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 2 - AREA E

FP111 FIRE PROTECTION PLAN - LEVEL 1 - AREA A

FP112 FIRE PROTECTION PLAN - LEVEL 1 - AREA B

FP113 FIRE PROTECTION PLAN - LEVEL 1 - AREA C

FP114 FIRE PROTECTION PLAN - LEVEL 1 - AREA D

FP115 FIRE PROTECTION PLAN - LEVEL 1 - AREA E

FP116 FIRE PROTECTION PLAN - LEVEL 1 - OPTION 1

FP117 FIRE PROTECTION PLAN - LEVEL 1 - OPTION 2

FP122 FIRE PROTECTION PLAN - LEVEL 2 - AREA B

FP123 FIRE PROTECTION PLAN - LEVEL 2 - AREA C

FP124 FIRE PROTECTION PLAN - LEVEL 2 - AREA D

FP125 FIRE PROTECTION PLAN - LEVEL 2 - AREA E

FA511 FIRE ALARM/ MASS NOTIFICATION DETAILS - PART I

FA512 FIRE ALARM/ MASS NOTIFICATION DETAILS - PART II

FP501 FIRE PROTECTION DETAILS - PART I

FP502 FIRE PROTECTION DETAILS - PART II

SHEET INDEX

NO NAME

MECHANICAL

MH120 OVERALL HVAC FLOOR PLAN - LEVEL 2

MH122 PARTIAL HVAC FLOOR PLAN - LEVEL 2 - AREA B

MH123 PARTIAL HVAC FLOOR PLAN - LEVEL 2 - AREA C

MH124 PARTIAL HVAC FLOOR PLAN - LEVEL 2 - AREA D

MH125 PARTIAL HVAC FLOOR PLAN - LEVEL 2 - AREA E

MH130 OVERALL ROOF PLAN

MP110 OVERALL PIPING FLOOR PLAN - LEVEL 1

MP111 PARTIAL PIPING FLOOR PLAN - LEVEL 1 - AREA A

MP112 PARTIAL PIPING FLOOR PLAN - LEVEL 1 - AREA B

MP113 PARTIAL PIPING FLOOR PLAN - LEVEL 1 - AREA C

MP114 PARTIAL PIPING FLOOR PLAN - LEVEL 1 - AREA D

MP115 PARTIAL PIPING FLOOR PLAN - LEVEL 1 - AREA E

MP116 OVERALL PIPING FLOOR PLAN - LEVEL 1 - BID OPTION 1

MP117 PARTIAL PIPING FLOOR PLAN - LEVEL 1 - BID OPTION 1

MP118 OVERALL PIPING FLOOR PLAN - LEVEL 1 - BID OPTION 2

MP119 PARTIAL PIPING FLOOR PLAN - LEVEL 1 - BID OPTION 2

MP120 OVERALL HVAC PIPING PLAN - LEVEL 2

MP122 PARTIAL PIPING FLOOR PLAN - LEVEL 2 - AREA B

MP123 PARTIAL PIPING FLOOR PLAN - LEVEL 2 - AREA C

MP124 PARTIAL PIPING FLOOR PLAN - LEVEL 2 - AREA D

MP125 PARTIAL PIPING FLOOR PLAN - LEVEL 2 - AREA E

M-301 HVAC SECTIONS

M-302 HVAC SECTIONS

M-401 ENLARGED PLAN - MAIN MECHANICAL YARD

M-402 ENLARGED PLAN - MAIN MECHANICAL ROOM

M-403 ENLARGED PLAN - EAST MECHANICAL ROOM

M-404 ENLARGED PLAN - EAST MECHANICAL YARD

M-405 ENLARGED PLAN - OPTION 2 MECHANICAL ROOM & YARD

M-501 MECHANICAL DETAILS

M-502 MECHANICAL DETAILS

M-503 MECHANICAL DETAILS

M-504 MECHANICAL DETAILS

M-505 MECHANICAL DETAILS

M-601 MECHANICAL SCHEDULES

M-602 MECHANICAL SCHEDULES

M-603 MECHANICAL SCHEDULES

M-604 MECHANICAL SCHEDULES

M-605 MECHANICAL SCHEDULES

M-606 MECHANICAL SCHEDULES

M-607 MECHANICAL SCHEDULES

M-701 HEATING WATER FLOW DIAGRAM

M-702 CHILLED WATER FLOW DIAGRAM

M-703 AHU & ERU CONFIGURATION DIAGRAMS

M-704 AHU & ERU CONFIGURATION DIAGRAMS

M-705 AHU-1 ISOMETRIC SUPPLY AIR LAYOUT - BASE BID

M-706 AHU-1 ISOMETRIC SUPPLY AIR LAYOUT - OPTION 1

M-707 AHU-2 ISOMETRIC SUPPLY AIR LAYOUT - BASE BID AND OPTION 2

M-801 HVAC CONTROLS

M-802 HVAC CONTROLS

M-803 HVAC CONTROLS

M-804 HVAC CONTROLS

M-805 HVAC CONTROLS

M-806 HVAC CONTROLS

M-807 HVAC CONTROLS

M-808 HVAC CONTROLS

M-809 HVAC CONTROLS

M-810 HVAC CONTROLS

M-811 HVAC SCHEDULES

M-812 POINTS LIST INSTRUCTIONS

M-813 IO POINTS

M-814 IO POINTS

M-815 IO POINTS

M-816 IO POINTS

M-817 IO POINTS

M-818 IO POINTS

M-819 IO POINTS

M-820 MECHANICAL SIGNAGE

MECHANICAL

M-001 GENERAL NOTES AND SYMBOLS

MH110 OVERALL HVAC FLOOR PLAN - LEVEL 1

MH111 PARTIAL HVAC FLOOR PLAN - LEVEL 1 - AREA A

MH112 PARTIAL HVAC FLOOR PLAN - LEVEL 1 - AREA B

MH113 PARTIAL HVAC FLOOR PLAN - LEVEL 1 - AREA C

MH114 PARTIAL HVAC FLOOR PLAN - LEVEL 1 - AREA D

MH115 PARTIAL HVAC FLOOR PLAN - LEVEL 1 - AREA E

MH116 OVERALL HVAC FLOOR PLAN - LEVEL 1 - BID OPTION 1

MH117 PARTIAL HVAC FLOOR PLAN - LEVEL 1 - BID OPTION 1

MH118 OVERALL HVAC FLOOR PLAN - LEVEL 1 - BID OPTION 2

MH119 PARTIAL HVAC FLOOR PLAN - LEVEL 1 - BID OPTION 2

GENERAL - VOLUME 5

G001E COVER SHEET

G002E SHEET INDEX

08/31/2020

B Y

C H

E C

K E

D B

Y

C H

E C

K E

D G

IN

G L

IS

C H

E C

K E

D G

IN

G L

IS

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

FIRE SPRINKLER SYSTEM GENERAL NOTES FIRE ALARM AND MASS NOTIFICATION SYSTEM GENERAL NOTESFIRE SPRINKLER SYMBOLS

WET SPRINKLER SYSTEM RISER

INSPECTOR'S TEST

CONNECTION/AUXILIARY DRAIN

GENERAL NOTES AND SYMBOLS

FIRE ALARM/MASS NOTIFICATION SYMBOLS

VALVE IN DROP

GATE VALVE

TEST PORT

PRESSURE GAUGE

PRESSURE CONTROL VALVE

RELIEF VALVE

CHECK VALVE

WITH GAUGE COCK

BLOWDOWN VALVE

ECCENTRIC REDUCER

TEE OUTLET DOWN

TEE OUTLET UP

STRAINER WITH

UNION

VALVE IN CENTER DROP

DIRECTION OF SLOPE DOWN

CONCENTRIC REDUCER

DIRECTION OF FLOW

VALVE IN RISE

ELBOW DOWN

ELBOW UP

(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)

FLOW TEST DATA

DATE OF TEST: 07/02/20

BY: BRAD IRMEN (JACOBS ENGINEERING)

LOCATION: ROBINS AIR FORCE BASE

SPRINKLER FLOOR CONTROL ASSEMBLY

WITH SUPERVISED CONTROL VALVE,

CHECK VALVE, WATER FLOW SWITCH

AND TEST/ DRAIN ASSEMBLY

P

R

S

FAT

FMCP

WP

M

WP

ANN

LOC

XX

M

RTS

MNRT

RPS

C

AMP

PIPING SYMBOLS

FLOW TEST RESULTS:

STATIC PRESSURE - 59 PSI

RESIDUAL PRESSURE - 47 PSI

TEST FLOW - 1,550 GPM

CD

XX

CD

XX

CD

XX

CD

TXT

DH

CO

SYMBOLS

1 HOUR FIRE RATED PARTITION

2 HOUR FIRE RATED PARTITION

FIRE SPRINKLER DESIGN CRITERIA

PATTERN OCCUPANCY SYSTEM

TYPE

DENSITY/

AREA

HOSE

ALLOWANCE

SPRINKLER

AREA OF

COVERAGE

SPRINKLER

K-FACTOR

(MIN.)

(NO

SHADING)

LIGHT HAZARD

(TYPICAL)

FOR CEILING

HEIGHTS UP TO 30 FT

WET

PIPE

SYSTEM

0.10

GPM/SF

OVER

MOST

REMOTE

1,500 SF

250 GPM 225 SF 5.6

ORDINARY HAZARD

(TYPICAL) FOR

CEILING HEIGHTS UP

TO 30 FT

0.20

GPM/SF

OVER

MOST

REMOTE

2,500 SF

250 GPM 130 SF 8.0

WET

PIPE

SYSTEM

FLOW

DURATION

60 MINUTES

60 MINUTES

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A

F R

C C

O N

S O

L

ID

A T

E D

M

IS

S

IO

N C

O M

P L

E X

P

H A

S E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V S

A R

O N

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

P R

O J E

C T

N U

M B

E R

U

H H

Z P

T B

D

F-001

G E

N E

R A

L N

O T

E S

A N

D S

Y M

B O

L S

R P

A R

K

J O

S T

W C

L A

Y

U H

H Z

F

-0

COMBINATION FIRE ALARM AND MASS NOTIFICATION CONTROL PANEL

WITH INTEGRATED AUTONOMOUS CONTROL UNIT AND MICROPHONE

FIRE ALARM AMPLIFIER PANEL

RECESSED LOCAL OPERATING CONSOLE WITH MICROPHONE AND

EMERGENCY AIR DISTRIBUTION SHUTOFF SWITCH

FEDERAL SIGNAL MASS NOTIFICATION RADIO TRANSCEIVER FOR

INTERFACE WITH BASE WIDE "BIG-VOICE" SYSTEM

AES INTELLINET 7788F FIRE ALARM SYSTEM RADIO TRANSMITTER

NOTIFICATION APPLIANCE REMOTE POWER SUPPLY/ TRANSPONDER

RECESSED LCD REMOTE ANNUNCIATOR PANEL

MANUAL PULL STATION

PHOTOELECTRIC SMOKE DETECTOR

WALL MOUNTED FIRE ALARM AND MASS NOTIFICATION COMBINED

SPEAKER/STROBE WITH CLEAR LENS MARKED "ALERT" ("XX"

INDICATES MINIMUM CANDELA RATING). A FEMALE VOICE WILL BE

USED TO DETERMINE IF THE ALARM IS A FIRE ALARM OR A MASS

NOTIFICATION ALARM.

CEILING MOUNTED FIRE ALARM AND MASS NOTIFICATION COMBINED

SPEAKER/STROBE WITH CLEAR LENS MARKED "ALERT" ("XX"

INDICATES MINIMUM CANDELA RATING). A FEMALE VOICE WILL BE

USED TO DETERMINE IF THE ALARM IS A FIRE ALARM OR A MASS

NOTIFICATION ALARM.

WALL MOUNTED FIRE ALARM AND MASS NOTIFICATION STROBE WITH

CLEAR LENS MARKED "ALERT" ("XX" INDICATES MINIMUM CANDELA

RATING).

CEILING MOUNTED FIRE ALARM AND MASS NOTIFICATION STROBE

WITH CLEAR LENS MARKED "ALERT" ("XX" INDICATES MINIMUM

CANDELA RATING).

WALL MOUNTED FIRE ALARM AND MASS NOTIFICATION SPEAKER

CEILING MOUNTED FIRE ALARM AND MASS NOTIFICATION SPEAKER

EXTERIOR WEATHERPROOF MASS NOTIFICATION SYSTEM LOUD

SPEAKER

WATER FLOW SWITCH

TAMPER SWITCH

THERMAL DETECTOR (COMBINATION 190° FIXED TEMPERATURE/RATE

OF RISE)

RETURN DUCT DETECTOR (SUPPLIED BY FIRE ALARM CONTRACTOR;

INSTALLED BY MECHANICAL CONTRACTOR)

SUPPLY DUCT DETECTOR (SUPPLIED BY FIRE ALARM CONTRACTOR;

INSTALLED BY MECHANICAL CONTRACTOR)

INDICATES WEATHER PROOF BACKBOX AND DEVICE

OMNI-DIRECTIONAL FIRE ALARM ANTENNA

FIRE/SMOKE DAMPER (PROVIDE DUCT DETECTOR WITHIN 5 FEET)

ADDRESSABLE MONITOR MODULE

ADDRESSABLE CONTROL MODULE

REMOTE TEST STATION WITH KEYSWITCH AND LED INDICATOR LIGHT

MASS NOTIFICATION LED TEXT SIGN WITH SCROLLING MESSAGE

DOOR HOLD-OPEN DEVICE

CARBON MONOXIDE DETECTOR

A. PROVIDE A COMPLETE WET-PIPE SPRINKLER SYSTEM THROUGHOUT THE BUILDING.

DESIGN AND INSTALLATION SHALL BE IN ACCORDANACE WITH UFC 3-600-01, NFPA 13,

SPECIFICATION 211313, AND ROBINS BASE FACILITY STANDARD PART 5E.

B. THE TOTAL CALCULATED WATER DEMAND FOR EACH OCCUPANCY IS EQUAL TO THE

SUM OF THE SPRINKLER SYSTEM DEMAND PLUS THE COMBINED HOSE STREAM

ALLOWANCE REQUIRED.

C. COORDINATE THE LOCATION OF RISERS, DRAINS, TEST CONNECTIONS, AND OTHER

SPRINKLER SYSTEM COMPONENTS WITH ARCHITECTURAL, STRUCTURAL,

MECHANICAL AND ELECTRICAL PORTIONS OF THE BUILDING. AUTOMATIC AIR VENTS

SHALL BE PROVIDED FOR WET-PIPE SPRINKLER SYSTEMS IN ACCORDANCE WITH

NPFA 13. INSPECTOR'S TEST CONNECTIONS SHALL BE CONNECTED AT THE

SPRINKLER SYSTEM RISER AND PIPED TO THE BUILDING EXTERIOR WITH A

SPLASHBLOCK PROVIDED.

D. WITHIN 6 MONTHS PRIOR TO SHOP DRAWING SUBMITTAL, CONTRACTOR SHALL

PERFORM A NEW FLOW TEST FOR PREPARING HYDRAULIC CALCULATIONS. VERIFY

THE SYSTEM DEMAND CAN BE SATISFIED BY THE AVAILABLE WATER SUPPLY. FLOW

TEST DATA PROVIDED BELOW WERE USED BY JACOBS TO VERIFY ADEQUACY OF THE

EXISTING WATER SUPPLY FOR PREPARATION OF THE CONTRACT DOCUMENTS.

E. HYDRAULICALLY CALCULATE THE WET-PIPE SPRINKLER SYSTEM IN ACCORDANCE

WITH THE FIRE SPRINKLER DESIGN CRITERIA TABLE PROVIDED ON FIRE SPRINKLER

PLANS. AREA REDUCTION IS NOT ALLOWED FOR QUICK RESPONSE SPRINKLERS.

F. PROVIDE PIPE HANGERS ON ALL SPRINKLER PIPING INSTALLED PER NFPA 13.

SEISMIC RESTRAINT IS NOT REQUIRED PER UFC 3-600-01, SECTION 9-7.10.3 BASED

ON DESIGNATION AS SEISMIC DESIGN CATEGORY B PER DRAWING S-001, GENERAL

NOTE 5.F.

G. IN AREAS WITH FINISHED CEILINGS, PROVIDE ORDINARY TEMPERATURE QUICK

RESPONSE CHROME PLATED RECESSED SPRINKLERS. CENTER SPRINKLERS IN BOTH

DIMENSIONS OF CEILING TILE, AND ALIGN SPRINKLERS WITH LIGHT FIXTURES FOR

GYP BOARD CEILINGS. SPRINKLERS MAY BE OFFSET FROM CENTERING AND

ALIGNMENT CRITERIA AS NECESSARY TO COORDINATE WITH ABOVE-CEILING

BUILDING SYSTEMS. NFPA 13 SPACING REQUIREMENTS SHALL BE OBSERVED. IN ALL

AREAS WITHOUT SUSPENDED CEILINGS, PROVIDE QUICK RESPONSE BRASS

UPRIGHT SPRINKLERS.

H. PROVIDE SPRINKLER HEAD GUARDS IN ELECTRONIC EQUIPMENT AREAS, ELEVATOR

MACHINE ROOMS, AND AREAS WHERE SPRINKLERS ARE LESS THAN 7 FEET ABOVE

FINISHED FLOOR OR SUBJECT TO MECHANICAL DAMAGE.

J. SEE ARCHITECTURAL DRAWINGS FOR ROOM FINISH SCHEDULE AND ROOM USE. SEE

ARCHITECTURAL REFLECTED CEILING PLANS FOR THE LOCATION OF ALL

CEILING-MOUNTED DEVICES.

K. PROVIDE SLEEVES AND WALL PLATES FOR ALL PENETRATIONS THROUGH WALLS OR

FLOORS THAT MIGHT INCLUDE DRILLING THROUGH CONCRETE, METAL, SHEETROCK,

OR OTHER MATERIALS. FIELD VERIFY APPROXIMATE WALL AND FLOOR

PENETRATIONS SHOWN ON THE PLANS. SEAL ALL PENETRATIONS IN RATED

SEPARATION TO MEET THE MINIMUM FIRE RATING OF THE WALL OR FLOOR. SLEEVES

ARE TO BE SIZED AND INSTALLED IN ACCORDANCE WITH EARTHQUAKE PROTECTION

REQUIREMENTS.

L. PROVIDE BLACK SCHEDULE 40 FOR ALL SPRINKLER SYSTEM PIPING. CONTRACTOR

MAY UTILIZE THREADED OR ROLL GROOVED FITTINGS. ROUTE SPRINKLER SYSTEM

PIPING ABOVE CEILINGS IN FINISHED AREAS.

M. MAINTAIN TEMPERATURES ABOVE 40 DEGREES F. IN ALL AREAS OF THE BUILDING

WHERE SPRINKLER SYSTEM PIPING IS ROUTED.

N. THESE DOCUMENTS DEPICT PERFORMANCE LEVEL ENGINEERING DESIGN CRITERIA

TO BE UTILIZED AS GUIDANCE FOR THE PLANNING OF THE FIRE SPRINKLER SYSTEM

BY THE CONTRACTOR. PROVIDE COMPLETE DOCUMENTS FOR REVIEW AND

APPROVAL FROM THE ENGINEER AND THE AUTHORITY HAVING JURISDICTION PRIOR

TO INSTALLATION. INCLUDE SHOP DRAWINGS, CALCULATIONS, AND ANY ADDITIONAL

EQUIPMENT NECESSARY TO PROVIDE A COMPLETE INSTALLATION AND COMPLY

WITH BASE STANDARDS.

A. PROVIDE A COMPLETE NEW FIRE ALARM AND MASS NOTIFICATION SYSTEM THROUGHOUT THE

BUILDING. DESIGN AND INSTALLATION SHALL BE IN ACCORDANCE WITH UFC 3-600-01, UFC 4-021-01, NFPA 72, SPECIFICATION 283176, AND ROBINS BASE FACILITY STANDARD PART 6H.

B. ALL JUNCTION BOXES SHALL BE LOCATED WITHIN 3 FT. OF THE ACOUSTICAL CEILING TILE (ACT) FOR ACCESSIBILITY. MECHANICAL EQUIPMENT AND DUCTWORK OR OTHER ASSOCIATED DEVICES SHALL

NOT BLOCK ACCESS TO ELECTRICAL JUNCTION BOXES.

C. RUN ALL WIRING IN MINIMUM 3/4" CONDUIT, EXCEPTION: 1/2" CONDUIT MAY BE USED FOR 120VAC POWER FROM A CIRCUIT BREAKER PANEL TO THE FIRE ALARM OR MASS NOTIFICATION SYSTEM.

D. MOUNT ALL WALL-MOUNTED NOTIFICATION APPLIANCES WITH THE BOTTOM OF THE STROBE LENS AT

80" AFF, OR 6" BELOW THE CEILING, WHICHEVER IS LOWER.

E. MOUNT THE OPERABLE PART OF MANUAL PULL STATIONS AT 48" AFF.

F. PROVIDE POWER LIMITED CIRCUITS.

G. DO NOT LOCATE DETECTORS IN DIRECT AIR OR CLOSER THAN 3 FEET FROM AN AIR SUPPLY OR

RETURN DIFFUSER.

H. PROVIDE CONNECTIONS TO THE LIGHT AND POWER SERVICE IN ACCORDANCE WITH NFPA 72.

J. PROVIDE 14 AWG MINIMUM INITIATING DEVICE AND 16 AWG MINIMUM SIGNALING LINE CIRCUITS.

K. PROVIDE 14 AWG MINIMUM VISUAL NOTIFICATION APPLIANCE CIRCUITS AND 16 AWG MINIMUM AUDIBLE

NOTIFICATION APPLIANCE CIRCUITS.

L. PROVIDE CLASS "A", SIGNALING LINE CIRCUITS, CLASS "A" INITIATING DEVICE CIRCUITS, AND CLASS "A" NOTIFICATION APPLIANCE CIRCUITS AS REQUIRED BY ROBINS BASE FACILITY STANDARD (BFS) PART 6H.

M. PROVIDE FIRE NOTIFICATION AND MASS NOTIFICATION DEVICES THROUGHOUT THE BUILDING IN ACCORDANCE WITH UFC 3-600-01. FIRE NOTIFICATION AND MASS NOTIFICATION DEVICES WILL BE A SINGLE VISIBLE APPLIANCE WITH A CLEAR LENS MARKED "ALERT". A FEMALE VOICE WILL BE USED TO DETERMINE IF THE ALARM IS A FIRE ALARM OR A MASS NOTIFICATION ALARM. LED TEXT DISPLAYS [TEXTUAL VISIBLE APPLIANCES] FOR HEARING IMPAIRED OCCUPANTS SHALL BE LOCATED OVER THE

DOOR TO EACH EGRESS STAIRWELL AND OVER [OR ADJACENT TO] THE SUBSTANTIAL MEANS OF

EGRESS FROM THE LEVEL OF DISCHARGE. THE SIGNS SHALL READ "EVACUATE" WHEN THE FIRE ALARM SYSTEM IS IN ALARM AND "ANNOUNCEMENT" WHEN A MASS NOTIFICATION MESSAGE IS BEING

TRANSMITTED.

N. WHERE CEILING HEIGHTS EXCEED TEN FEET, ADJUST CEILING MOUNTED VISIBLE NOTIFICATION APPLIANCE CANDELA RATINGS IN ACCORDANCE WITH NFPA 72 TABLE 18.5.5.4.1(b).

P. PROVIDE AUTOMATIC CLOSING DOORS WITHIN THE SMOKE BARRIER. PROVIDE DOOR HOLD DEVICES TO BE RELEASED UPON ACTIVATION OF SMOKE DETECTORS IN THE COMMUNICATING SPACE, WHERE

DOORS ARE NORMALLY OPEN.

Q. PROVIDE COMPLETE VOLTAGE DROP AND BATTERY CALCULATIONS IN ACCORDANCE WITH NFPA 72 FOR THE FIRE ALARM AND MASS NOTIFICATION SYSTEM. PROVIDE ADDITIONAL CIRCUITS AND/OR

BATTERIES WHERE NECESSARY FOR COMPLIANCE WITH NFPA 72 AND THE SPECIFICATIONS.

R. LOCATE MASS NOTIFICATION APPLIANCES IN ACCORDANCE WITH NFPA 72 FOR VISIBLE, AUDIBLE, AND INTELLIGIBLE NOTIFICATION. UPON ACTIVATION OF THE MASS NOTIFICATION SYSTEM, TEMPORARILY DEACTIVATE MASS NOTIFICATION SYSTEM AUDIBLE AND VISUAL SIGNALS DURING EMERGENCY VOICE MESSAGING. FIRE ALARM VISUALS AND SIGNAL TRANSMISSION TO THE BASE FIRE DEPARTMENT ARE TO REMAIN FUNCTIONAL. REACTIVATE THE MASS NOTIFICATION AUDIBLES AND VISUALS AFTER THE

MESSAGE IS COMPLETED.

S. MNS SHALL NOT OVERRIDE THE FIRE ALARM MESSAGE FOR MORE THAN 10 MINUTES. AFTER 10 MINUTES, IF NO MANUAL ACTION HAS BEEN TAKEN, THE LOCAL MNS MESSAGE SHALL AUTOMATICALLY END. CENTRALLY ACTIVATED MESSAGES SHALL CONTINUE UNTIL TERMINATED BY COMMAND POST.

T. MASS NOTIFICATION SYSTEM SHALL BE CAPABLE OF RECEIVING MESSAGES FROM THE FEDERAL

SIGNAL BASE-WIDE SYSTEM.

U. POST INDICATOR VALVE ON THE 8 INCH UNDERGROUND BULDING FIRE MAIN WILL BE LOCKED IN THE

OPEN POSITION PER BASE FACILITY STANDARD PART 6H-11.8.

V. THESE DOCUMENTS DEPICT PERFORMANCE LEVEL ENGINEERING DESIGN LAYOUT TO BE UTILIZED AS

GUIDANCE FOR THE PLANNING OF THE FIRE ALARM AND MASS NOTIFICATION SYSTEMS BY THE

CONTRACTOR. PROVIDE COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL FROM THE ENGINEER

AND THE AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. INCLUDE SHOP DRAWINGS, CALCULATIONS, AND ANY ADDITIONAL EQUIPMENT NECESSARY TO PROVIDE A COMPLETE

INSTALLATION AND COMPLY WITH BASE STANDARDS.

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

WP

M

WP

M

WP

M

P

P P

P

WP

M

CORR

1.5 2.5

MAIN ELEC

SB STORAGE

HOH STUDIO

159A

HOH

MAIN MECH

STAIR 1

M A

T C

H L

IN

EC

F A

EXTERIOR MECHANICAL YARD

TXT

TXT

T X

T

1 2 3

G

F

E

C.5

C

G.5

3.30.20.5

D

D.2

C

TRUE NORTH

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A

F R

C C

O N

S O

L

ID

A T

E D

M

IS

S

IO

N C

O M

P L

E X

P

H A

S E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V S

A R

O N

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

A

AREA A

KEY PLAN

PHASE 3PHASE 1

P R

O J E

C T

N U

M B

E R

U

H H

Z P

B C

D E

T B

D

FA111

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

P L A

N

L E

V E

L

A

R E

A A

R P

A R

K

J O

S T

W C

L A

Y

U H

H Z

F

A

SCALE 1/8" = 1'-0"

A2 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 1 - AREA A

GENERAL NOTES - FIRE ALARM

A REFER TO SHEET GI002 AND GI003 FOR LIST OF

ABBREVIATIONS USED IN DRAWINGS. REFER TO SHEET

GI012 FOR ROOM SCHEDULE.

B REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS,

AND GENERAL NOTES.

C REFER TO SHEET FA511 AND FA512 FOR FIRE ALARM/

MASS NOTIFICATION RISER DIAGRAM, SEQUENCE OF

OPERATIONS, AND DETAILS.

D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS

FOR COORDINATION WITH LIGHTS, MECHANICAL

DIFFUSERS, AND CEILING GRID.

KEYNOTES

154 ADDRESSABLE CONTROL MODULE AT LIGHTING

INVERTER FOR ACTIVATION OF EMERGENCY LIGHTING

CONTROL UPON FIRE ALARM SIGNAL PER NFPA 101 FOR

ILLUMINATION OF MEANS OF EGRESS. RE: ELECTRICAL

DRAWINGS FOR INVERTER LOCATIONS.

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

WP

M

P

P P

RTS

PRINTING/WORK

ROOM

VIDEO STUDIO

STORAGE

170A

EQUIP

ROOM

166E

CONTROL

ROOM

VIDEO

GRAPHICS

PA

DEP DIR

171G

PA DIR

171H

STG

SR

ENL ADV

171F

LOBBY / STAIR 2

PA STG

171D

PAO DIV CH

171C

PAR DIV CH

171B

PA

EDIT

166D

EDIT

166C

EDIT

166B

TRAINING

PA DIR SUITE

171E

SE STG

102A

M A

T C

H L

IN

E

A

F A

MATCHLINE

B1 FA114

M A

T C

H L

IN

E

C

F A

A N

N

TXT

3.7 3.9 4 4.7 5 6 6.5 7 7.6 8

G

F

G.5

7.3

J

4.53.6

DUB

166A

PAI

166F

STORAGE

166G

151151

TRUE NORTH

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A

F R

C C

O N

S O

L

ID

A T

E D

M

IS

S

IO

N C

O M

P L

E X

P

H A

S E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V S

A R

O N

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

B

AREA B

KEY PLAN

P R

O J E

C T

N U

M B

E R

U

H H

Z P

A

C

ED

T B

D

FA112

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

P L A

N

L E

V E

L

A

R E

A B

R P

A R

K

J O

S T

W C

L A

Y

U H

H Z

F

A

SCALE 1/8" = 1'-0"

A1 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 1 - AREA B

GENERAL NOTES - FIRE ALARM

A REFER TO SHEET GI002 AND GI003 FOR LIST OF

ABBREVIATIONS USED IN DRAWINGS. REFER TO SHEET

GI012 FOR ROOM SCHEDULE.

B REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS,

AND GENERAL NOTES.

C REFER TO SHEET FA511 AND FA512 FOR FIRE ALARM/

MASS NOTIFICATION RISER DIAGRAM, SEQUENCE OF

OPERATIONS, AND DETAILS.

D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS

FOR COORDINATION WITH LIGHTS, MECHANICAL

DIFFUSERS, AND CEILING GRID.

KEYNOTES

106 PROVIDE REMOTE TEST STATION WITH KEYSWITCH AND

LED INDICATOR.

117 PROVIDE RECESS MOUNTED LCD ANNUNCIATOR.

148 PROVIDE SMOKE DAMPER WHERE DUCTS PENETRATE

THE SMOKE PARTITION. DUCT SMOKE DETECTORS

SHALL BE INSTALLED WITHIN 5 FEET OF DAMPERS.

151 NOTIFICATION SHOWN ON LEVEL 2.

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

R

S

R T

S

R T

S

TRAINING

SE

SE STG

102A

SPT

102B DEP DIR

102C

DIRECTOR

102D

SG DIR

110M DEP DIR

110N

SR ENL ADV

110L

SGX

110C

SGX DIV CH

110D

SG DIR SUITE

110E

SG

SGN

110F

DRUG

110G

SGS

110H

MED CONF

MATCHLINE

B1 FA115

M A

T C

H L

IN

E

A

F A

7.6 8 9 9.5 10 11 11.5 12 12.5 13

G

F

G.5

J

12.6 13.1

H

G.6

150150

S

TRUE NORTH

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A

F R

C C

O N

S O

L

ID

A T

E D

M

IS

S

IO

N C

O M

P L

E X

P

H A

S E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V S

A R

O N

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

KEY PLAN

C

AREA C

P R

O J E

C T

N U

M B

E R

U

H H

Z P

B

A D E

T B

D

FA113

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

P L A

N

L E

V E

L

A

R E

A C

R P

A R

K

J O

S T

W C

L A

Y

U H

H Z

F

A

SCALE 1/8" = 1'-0"

C1 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 1 - AREA C

GENERAL NOTES - FIRE ALARM

A REFER TO SHEET GI002 AND GI003 FOR LIST OF

ABBREVIATIONS USED IN DRAWINGS. REFER TO SHEET

GI012 FOR ROOM SCHEDULE.

B REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS,

AND GENERAL NOTES.

C REFER TO SHEET FA511 AND FA512 FOR FIRE ALARM/

MASS NOTIFICATION RISER DIAGRAM, SEQUENCE OF

OPERATIONS, AND DETAILS.

D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS

FOR COORDINATION WITH LIGHTS, MECHANICAL

DIFFUSERS, AND CEILING GRID.

KEYNOTES

106 PROVIDE REMOTE TEST STATION WITH KEYSWITCH AND

LED INDICATOR.

123 PROVIDE DUCT SMOKE DETECTORS IN ALL SUPPLY

DUCTS FOR AHUS GREATER THAN 2,000 CFM, PROVIDE

DUCT SMOKE DETECTOR ON RETURN AND SUPPLY SIDE

OF AHUS OVER 15,000 CFM PER NFPA 90A AND UFC

3-600-01.

150 CONVENIENCE STAIR FLOOR OPENING, NOTIFICATION

SHOWN ON LEVEL 2.

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

RPS

A N

N

WP

M

WP

M

P

P

P

RTS

R T

S

P

RTS

STAIR 1

MAIN MECH

TR

EDIT

166D

EDIT

166C

EDIT

166B

WOMENS

MENS

HOH

149D

HO

HOS

149C

HO DIR

149B

HO DEP DIR

149A

HERITAGE

STG

ARCHIVES

CORR

101A

CUST

PICKUP

STORAGE

166G

GREEN

165A PA

SB PREP

CORR

101A

MICRO

FILM

MED CONF

ELEV

101C

STAIR 3

PAR DIV CH

171B

PAY DIV CH

171A

M A

T C

H L

IN

E

A

F A

MATCHLINE

A1 FA112

M A

T C

H L

IN

E

B

F A

LOC

AMP142

AMP

M

3 3.7 3.9 4 4.7 5 6 6.5 7 7.6 8

F

E

C.5

C

B

A

3.3 7.3

D

D.2

4.5

0.A

3.6

ELEC (SB)

162A

DUB

166A

SNACK BAR

SB STORAGE

FAT

MNRT

RPS

115 118

144 139

R

S123

T X

T

TXT

RECYCLE

co

FMCP

TRUE NORTH

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A

F R

C C

O N

S O

L

ID

A T

E D

M

IS

S

IO

N C

O M

P L

E X

P

H A

S E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V S

A R

O N

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

KEY PLAN

P R

O J E

C T

N U

M B

E R

U

H H

Z P

D

AREA D

B

A

C

E

T B

D

FA114

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

P L A

N

L E

V E

L

A

R E

A D

R P

A R

K

J O

S T

W C

L A

Y

U H

H Z

F

A

SCALE 1/8" = 1'-0"

B1 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 1 - AREA D

GENERAL NOTES - FIRE ALARM

A REFER TO SHEET GI002 AND GI003 FOR LIST OF

ABBREVIATIONS USED IN DRAWINGS. REFER TO SHEET

GI012 FOR ROOM SCHEDULE.

B REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS,

AND GENERAL NOTES.

C REFER TO SHEET FA511 AND FA512 FOR FIRE ALARM/

MASS NOTIFICATION RISER DIAGRAM, SEQUENCE OF

OPERATIONS, AND DETAILS.

D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS

FOR COORDINATION WITH LIGHTS, MECHANICAL

DIFFUSERS, AND CEILING GRID.

KEYNOTES

106 PROVIDE REMOTE TEST STATION WITH KEYSWITCH AND

LED INDICATOR.

115 COMBINATION FIRE ALARM/ MASS NOTIFICATION

CONTROL PANEL WITH INTEGRATED AUTONOMOUS

CONTROL UNIT (ACU).

116 PROVIDE RECESS MOUNTED LOCAL OPERATING

CONSOLE WITH MICROPHONE AND EMERGENCY AIR

DISTRIBUTION SHUTOFF SWITCH IN ACCORDANCE WITH

UFC 4-010-01 SECTION B-4.3.

117 PROVIDE RECESS MOUNTED LCD ANNUNCIATOR.

118 AES INTELLINET 7788F FIRE ALARM RADIO

TRANSMITTER. REFER TO ARCHITECTURAL SHEETS FOR

ANTENNA MOUNTING LOCATION. ROUTE CABLE FROM

ANTENNA TO TRANSMITTER PER MANUFACTURER'S

RECOMMENDATIONS. REFER TO A7/FA512 FOR ANTENNA

DETAIL.

121 SMOKE DETECTOR FOR PROTECTION OF PANELS.

123 PROVIDE DUCT SMOKE DETECTORS IN ALL SUPPLY

DUCTS FOR AHUS GREATER THAN 2,000 CFM, PROVIDE

DUCT SMOKE DETECTOR ON RETURN AND SUPPLY SIDE

OF AHUS OVER 15,000 CFM PER NFPA 90A AND UFC

3-600-01.

127 MONITOR TAMPER SWITCH ON ELEVATOR PIT

SPRINKLER ISOLATION CONTROL VALVE.

139 PROVIDE FEDERAL SIGNAL MASS NOTIFICATION RADIO

TRANSCEIVER FOR INTERFACE WITH BASE WIDE

"BIG-VOICE" SYSTEM. REFER TO ARCHITECTURAL

SHEETS FOR ANTENNA MOUNTING LOCATION. ROUTE

CABLE FROM ANTENNA TO TRANSCEIVER PER

MANUFACTURER'S RECOMMENDATIONS. REFER TO

A7/FA512 FOR ANTENNA DETAIL.

142 PROVIDE NOTIFICATION APPLIANCE REMOTE POWER

SUPPLY/ TRANSPONDER.

144 PROVIDE FIRE ALARM AMPLIFIER PANEL.

148 PROVIDE SMOKE DAMPER WHERE DUCTS PENETRATE

THE SMOKE PARTITION. DUCT SMOKE DETECTORS

SHALL BE INSTALLED WITHIN 5 FEET OF DAMPERS.

152 CARBON MONOXIDE DETECTOR IN MECHANICAL ROOM

IN ACCORDANCE WITH NFPA 72 FOR FUEL FIRED BOILER.

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

A N

N

RPS

WP

W P

M

P

P

R T

S

R T

S

CORR

101A

CONF / TRAINING

STG

VTC

STG

145A

VTC CONF

ELEV

101C

STAIR 3

A9

CORR

101A

WOMENS

MENS

TRAINING

SEF

102E

SEW

102F

SEG

102G

JAN

TR

SG STG

110A

SG

CORR

101A

ELEC

TR

BREAK

113 VTC CONF

STAIR 4

IP

VTC STG

114A

FIRE PROT

ELEC

A9 DEP DIR

141D

A9 DIR

141C

SGO

DIV CH

110K

SGD

110J

SGSI STG

110B

WELLNESS

SGX

110C

IP DIR

140C

SIPR

140B

IP STORAGE

140A

M A

T C

H L

IN

E

B

F A

MATCHLINE

C1 FA113

AMP 142

M

M

M

TXT

T X

T

7.6 8 9 9.5 10 11 11.5 12 12.5 13

F

E

C.5

C

B

A

7.3

D

D.2

12.6 13.1

D.8

D.1

0.A

A9A DIV CH

141B

Room

A9

STORAGE

141F

SIPR

WORK RM

141E

S

M

M

M

M 130

S

C

TRUE NORTH

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A

F R

C C

O N

S O

L

ID

A T

E D

M

IS

S

IO

N C

O M

P L

E X

P

H A

S E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V S

A R

O N

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

KEY PLAN

E

AREA E

P R

O J E

C T

N U

M B

E R

U

H H

Z P

CB

D A

T B

D

FA115

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

P L A

N

L E

V E

L

A

R E

A E

R P

A R

K

J O

S T

W C

L A

Y

U H

H Z

F

A

SCALE 1/8" = 1'-0"

B1 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 1 - AREA E

GENERAL NOTES - FIRE ALARM

A REFER TO SHEET GI002 AND GI003 FOR LIST OF

ABBREVIATIONS USED IN DRAWINGS. REFER TO SHEET

GI012 FOR ROOM SCHEDULE.

B REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS,

AND GENERAL NOTES.

C REFER TO SHEET FA511 AND FA512 FOR FIRE ALARM/

MASS NOTIFICATION RISER DIAGRAM, SEQUENCE OF

OPERATIONS, AND DETAILS.

D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS

FOR COORDINATION WITH LIGHTS, MECHANICAL

DIFFUSERS, AND CEILING GRID.

KEYNOTES

130 MONITOR TAMPER AND FLOW SWITCHES ON THE FIRE

SPRINKLER FLOOR CONTROL VALVE ASSEMBLY.

142 PROVIDE NOTIFICATION APPLIANCE REMOTE POWER

SUPPLY/ TRANSPONDER.

144 PROVIDE FIRE ALARM AMPLIFIER PANEL.

154 ADDRESSABLE CONTROL MODULE AT LIGHTING

INVERTER FOR ACTIVATION OF EMERGENCY LIGHTING

CONTROL UPON FIRE ALARM SIGNAL PER NFPA 101 FOR

ILLUMINATION OF MEANS OF EGRESS. RE: ELECTRICAL

DRAWINGS FOR INVERTER LOCATIONS.

KEYNOTES

106 PROVIDE REMOTE TEST STATION WITH KEYSWITCH AND

LED INDICATOR.

119 MONITOR SPRINKLER SYSTEM WATER FLOW (TYP. 2)

AND TAMPER SWITCHES (TYP. 5).

121 SMOKE DETECTOR FOR PROTECTION OF PANELS.

122 PROVIDE SMOKE DETECTOR IN ELEVATOR LOBBY FOR

ELEVATOR RECALL.

123 PROVIDE DUCT SMOKE DETECTORS IN ALL SUPPLY

DUCTS FOR AHUS GREATER THAN 2,000 CFM, PROVIDE

DUCT SMOKE DETECTOR ON RETURN AND SUPPLY SIDE

OF AHUS OVER 15,000 CFM PER NFPA 90A AND UFC

3-600-01.

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

P

3.9 4

4.7

5 6

6.5 7

A

4.5

0.C

0.B

0.A

RS

RSO

150F

RSX

150G

RS

150A

CEM

150C

RS DIR SUITE

150B

RS DEP DIR

150E

RS DIR

150D

HO DIR

149B

HOS

149C

HOH

149D

HERITAGE

STG

149E

HO

HO DEP DIR

149A

HATCHED AREA INDICATES BASE

BID; REFER TO BASE BID DRAWING

BID OPTION LEGEND

SCALE: 3/16"=1'-0"

48 8

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A

F R

C C

O N

S O

L

ID

A T

E D

M

IS

S

IO

N C

O M

P L

E X

P

H A

S E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V S

A R

O N

I

F

IL

E N

A M

E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

KEY PLAN

P R

O J E

C T

N U

M B

E R

U

H H

Z P

OPTION 1

OPT 1

B

A

C

ED

T B

D

FA116

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

P L A

N

L E

V E

L

O P

T

IO

N

R P

A R

K

J O

S T

W C

L A

Y

U H

H Z

F

A

SCALE 3/16" = 1'-0"

B1 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 1 - OPTION 1

GENERAL NOTES - FIRE ALARM

A REFER TO SHEET GI002 AND GI003 FOR LIST OF

ABBREVIATIONS USED IN DRAWINGS. REFER TO SHEET

GI012 FOR ROOM SCHEDULE.

B REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS,

AND GENERAL NOTES.

C REFER TO SHEET FA511 AND FA512 FOR FIRE ALARM/

MASS NOTIFICATION RISER DIAGRAM, SEQUENCE OF

OPERATIONS, AND DETAILS.

D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS

FOR COORDINATION WITH LIGHTS, MECHANICAL

DIFFUSERS, AND CEILING GRID.

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

LOC P

P

P

RTS

WP

M

RTS

P

R T

S

M

M

12.5 13

G

F

E

C.5

C

B

G.5

J

D

D.2

12.6 13.1 14 14.5 17 18

H

G.6

D.8

D.1

R

R

123123

DH

DH

DH

DH

T X

T T

X T

AUDITORIUM

CONTROL

GREEN RM

MECH

CORR

WOMENS

MENS

FMAH

RPO

RR

117A

ELEC

STAIR 4

M

M

MECH YARD

100C

TXT

T X

T

T X

T

C

HATCHED AREA INDICATES BASE

BID; REFER TO BASE BID DRAWING

BID OPTION LEGEND

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A

F R

C C

O N

S O

L

ID

A T

E D

M

IS

S

IO

N C

O M

P L

E X

P

H A

S E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V S

A R

O N

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

KEY PLAN

OPT

OPTION 2

P R

O J E

C T

N U

M B

E R

U

H H

Z P

B

A

C

ED

T B

D

FA117

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

P L A

N

L E

V E

L

O

P T

IO

N

R P

A R

K

J O

S T

W C

L A

Y

U H

H Z

F

A

SCALE 1/8" = 1'-0"

A1 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 1 - OPTION 2

KEYNOTES

106 PROVIDE REMOTE TEST STATION WITH KEYSWITCH AND

LED INDICATOR.

119 MONITOR SPRINKLER SYSTEM WATER FLOW (TYP. 2)

AND TAMPER SWITCHES (TYP. 5).

123 PROVIDE DUCT SMOKE DETECTORS IN ALL SUPPLY

DUCTS FOR AHUS GREATER THAN 2,000 CFM, PROVIDE

DUCT SMOKE DETECTOR ON RETURN AND SUPPLY SIDE

OF AHUS OVER 15,000 CFM PER NFPA 90A AND UFC

3-600-01.

130 MONITOR TAMPER AND FLOW SWITCHES ON THE FIRE

SPRINKLER FLOOR CONTROL VALVE ASSEMBLY.

147 PROVIDE SMOKE DETECTOR WITHIN 5 FEET OF DOOR

FOR RELEASE OF DOOR HOLDERS.

153 PROVIDE 8 WATT RATED SPEAKERS WITH ADJUSTABLE

TAPS. TAPS ARE TO BE SET IN THE FIELD BY THE

INSTALLER TO ACHIEVE DESIRED AUDIBILITY AND

INTELLIGIBILITY REQUIREMENTS.

154 ADDRESSABLE CONTROL MODULE AT LIGHTING

INVERTER FOR ACTIVATION OF EMERGENCY LIGHTING

CONTROL UPON FIRE ALARM SIGNAL PER NFPA 101 FOR

ILLUMINATION OF MEANS OF EGRESS. RE: ELECTRICAL

DRAWINGS FOR INVERTER LOCATIONS.

GENERAL NOTES - FIRE ALARM

A REFER TO SHEET GI002 AND GI003 FOR LIST OF

ABBREVIATIONS USED IN DRAWINGS. REFER TO SHEET

GI012 FOR ROOM SCHEDULE.

B REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS,

AND GENERAL NOTES.

C REFER TO SHEET FA511 AND FA512 FOR FIRE ALARM/

MASS NOTIFICATION RISER DIAGRAM, SEQUENCE OF

OPERATIONS, AND DETAILS.

D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS

FOR COORDINATION WITH LIGHTS, MECHANICAL

DIFFUSERS, AND CEILING GRID.

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

PK

A1K

CONFERENCE

MATCHLINE

B1 FA124

M A

T C

H L

IN

E

B

F A

LOBBY / STAIR 2

202B

SS STG

263A

SOURCE

SELECTION

263B

PK DIR

263C

PKA

263D

PKO

263E

STORAGE

263F

3.7 3.9 4 4.7 5 6 6.5 7 7.6 8

G

F

G.5

7.3

J

4.53.6

VIDEO STUDIO

TRUE NORTH

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A

F R

C C

O N

S O

L

ID

A T

E D

M

IS

S

IO

N C

O M

P L

E X

P

H A

S E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V S

A R

O N

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

B

AREA B

KEY PLAN

P R

O J E

C T

N U

M B

E R

U

H H

Z P

A

C

ED

T B

D

FA122

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

P L A

N

L E

V E

L

A

R E

A B

R P

A R

K

J O

S T

W C

L A

Y

U H

H Z

F

A

SCALE 1/8" = 1'-0"

A1 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 2 - AREA B

GENERAL NOTES - FIRE ALARM

A REFER TO SHEET GI002 AND GI003 FOR LIST OF

ABBREVIATIONS USED IN DRAWINGS. REFER TO SHEET

GI012 FOR ROOM SCHEDULE.

B REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS,

AND GENERAL NOTES.

C REFER TO SHEET FA511 AND FA512 FOR FIRE ALARM/

MASS NOTIFICATION RISER DIAGRAM, SEQUENCE OF

OPERATIONS, AND DETAILS.

D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS

FOR COORDINATION WITH LIGHTS, MECHANICAL

DIFFUSERS, AND CEILING GRID.

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

S R T

S

MET

203A

IG

IGQ

MATCHLINE

B1 FA125

M A

T C

H L

IN

E

A

F A

CONF

203C

CONF

203D

IGI

215C

IGA

215B

STG

215A

CONFERENCE

LOBBY / STAIR 2

202B

IG DIR SUITE

215D

IG DEP DIR

215E

IG DIR

215F

CEM

215G

INTERVIEW

219B

IGQ

219A

CORR

7.6 8 9 9.5 10 11 11.5 12 12.5 13

G

F

G.5

J

12.6 13.1

H

G.6

TRUE NORTH

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A

F R

C C

O N

S O

L

ID

A T

E D

M

IS

S

IO

N C

O M

P L

E X

P

H A

S E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V S

A R

O N

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

KEY PLAN

C

AREA C

P R

O J E

C T

N U

M B

E R

U

H H

Z P

B

A D E

T B

D

FA123

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

P L A

N

L E

V E

L

A

R E

A C

R P

A R

K

J O

S T

W C

L A

Y

U H

H Z

F

A

SCALE 1/8" = 1'-0"

B1 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 2 - AREA C

GENERAL NOTES - FIRE ALARM

A REFER TO SHEET GI002 AND GI003 FOR LIST OF

ABBREVIATIONS USED IN DRAWINGS. REFER TO SHEET

GI012 FOR ROOM SCHEDULE.

B REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS,

AND GENERAL NOTES.

C REFER TO SHEET FA511 AND FA512 FOR FIRE ALARM/

MASS NOTIFICATION RISER DIAGRAM, SEQUENCE OF

OPERATIONS, AND DETAILS.

D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS

FOR COORDINATION WITH LIGHTS, MECHANICAL

DIFFUSERS, AND CEILING GRID.

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

LOC

P

RTS

STAIR 1

VTC CONF

VTC

CLOSET

256A

STG

TR

MENS

WOMENS

CORR

AFO

250B

ELEC

HC

CONF

CONF

JA DIR

233D

JA STG

233E

A1K

CONF

CONF

ELEV

EQUIP

ELEV

202A

STG

STAIR 3

COUNSEL

248A

STG

248G

DET. CC

250A

HC DIR

248F

HC DEP DIR

248E

MFM

248D

HCX

248B

HCP

248C

EEO

265B

A1K 265A

MATCHLINE

A1 FA122

M A

T C

H L

IN

E

B

F A

AMP

T X

T

M

M

3 3.7 3.9 4 4.7 5 6 6.5 7 7.6 8

F

E

C.5

C

B

A

3.3 7.3

D

D.2

4.5

0.A

3.6

OSI

R

M

M

REC

C

TRUE NORTH

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A

F R

C C

O N

S O

L

ID

A T

E D

M

IS

S

IO

N C

O M

P L

E X

P

H A

S E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V S

A R

O N

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

KEY PLAN

P R

O J E

C T

N U

M B

E R

U

H H

Z P

D

AREA D

B

A

C

E

T B

D

FA124

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

P L A

N

L E

V E

L

A

R E

A D

R P

A R

K

J O

S T

W C

L A

Y

U H

H Z

F

A

SCALE 1/8" = 1'-0"

B1 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 2 - AREA D

GENERAL NOTES - FIRE ALARM

A REFER TO SHEET GI002 AND GI003 FOR LIST OF

ABBREVIATIONS USED IN DRAWINGS. REFER TO SHEET

GI012 FOR ROOM SCHEDULE.

B REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS,

AND GENERAL NOTES.

C REFER TO SHEET FA511 AND FA512 FOR FIRE ALARM/

MASS NOTIFICATION RISER DIAGRAM, SEQUENCE OF

OPERATIONS, AND DETAILS.

D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS

FOR COORDINATION WITH LIGHTS, MECHANICAL

DIFFUSERS, AND CEILING GRID.

KEYNOTES

125 ELEVATOR MACHINE ROOM SMOKE DETECTOR TO

RECALL ELEVATOR TO ALTERNATE FLOOR PRIOR TO

SHUNT TRIP.

130 MONITOR TAMPER AND FLOW SWITCHES ON THE FIRE

SPRINKLER FLOOR CONTROL VALVE ASSEMBLY.

142 PROVIDE NOTIFICATION APPLIANCE REMOTE POWER

SUPPLY/ TRANSPONDER.

144 PROVIDE FIRE ALARM AMPLIFIER PANEL.

154 ADDRESSABLE CONTROL MODULE AT LIGHTING

INVERTER FOR ACTIVATION OF EMERGENCY LIGHTING

CONTROL UPON FIRE ALARM SIGNAL PER NFPA 101 FOR

ILLUMINATION OF MEANS OF EGRESS. RE: ELECTRICAL

DRAWINGS FOR INVERTER LOCATIONS.

KEYNOTES

106 PROVIDE REMOTE TEST STATION WITH KEYSWITCH AND

LED INDICATOR.

116 PROVIDE RECESS MOUNTED LOCAL OPERATING

CONSOLE WITH MICROPHONE AND EMERGENCY AIR

DISTRIBUTION SHUTOFF SWITCH IN ACCORDANCE WITH

UFC 4-010-01 SECTION B-4.3.

121 SMOKE DETECTOR FOR PROTECTION OF PANELS.

123 PROVIDE DUCT SMOKE DETECTORS IN ALL SUPPLY

DUCTS FOR AHUS GREATER THAN 2,000 CFM, PROVIDE

DUCT SMOKE DETECTOR ON RETURN AND SUPPLY SIDE

OF AHUS OVER 15,000 CFM PER NFPA 90A AND UFC

3-600-01.

124 MONITOR FLOW AND TAMPER SWITCHES AT CONTROL

VALVE FOR SPRINKLER PIPING SERVING ELEVATOR

MACHINE ROOM.

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

LOC P

R T

S R T

S

RTS

JA DEP DIR

233C

SUPER

233B

VISIT ATTY

232N

JAM

232M

JAA

232L

JAA

232K

JAA

232J

JAA

232H

JAA

232G

JAO

232F

JA

CC

233A

JAM

232P

ELEV

EQUIP

JA STG

233E

JA DIR

233D

VISIT ATTY

232B

JAR

232A

JAZ

232E

JA CONF

232D

CONF

FILING

232C

VISIT ATTY

230E

VISIT ATTY

230D

COURT

REPORTER

230C

BOARD ROOM

230B

DELIBERATION

ROOM

230A

STAIR 4

MECH

ELEC

TR

BREAK

IG SIPR

CAFE

215H

JAN

TR

MENS

WOMENS

STAIR 3

STG

A1 STG

203E

STG

215A

ELEC

MATCHLINE

B1 FA123

M A

T C

H L

IN

E

A

F A

AMP

M

M

T X

T

IG

YR

203B

7.6 8 9 9.5 10 11 11.5 12 12.5 13

F

E

C.5

C

B

A

7.3

D

D.2

12.6 13.1

D.8

D.1

0.A

ELEV

202A

JA

R

R

M

M

M

M

123106

TXT

C

TRUE NORTH

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A

F R

C C

O N

S O

L

ID

A T

E D

M

IS

S

IO

N C

O M

P L

E X

P

H A

S E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V S

A R

O N

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

KEY PLAN

E

AREA E

P R

O J E

C T

N U

M B

E R

U

H H

Z P

CB

D A

T B

D

FA125

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

P L A

N

L E

V E

L

A

R E

A E

R P

A R

K

J O

S T

W C

L A

Y

U H

H Z

F

A

SCALE 1/8" = 1'-0"

B1 FIRE ALARM/ MASS NOTIFICATION PLAN - LEVEL 2 - AREA E

GENERAL NOTES - FIRE ALARM

A REFER TO SHEET GI002 AND GI003 FOR LIST OF

ABBREVIATIONS USED IN DRAWINGS. REFER TO SHEET

GI012 FOR ROOM SCHEDULE.

B REFER TO SHEET F-001 FOR ABBREVIATIONS, SYMBOLS,

AND GENERAL NOTES.

C REFER TO SHEET FA511 AND FA512 FOR FIRE ALARM/

MASS NOTIFICATION RISER DIAGRAM, SEQUENCE OF

OPERATIONS, AND DETAILS.

D REFER TO ARCHITECTURAL REFLECTED CEILING PLANS

FOR COORDINATION WITH LIGHTS, MECHANICAL

DIFFUSERS, AND CEILING GRID.

KEYNOTES

130 MONITOR TAMPER AND FLOW SWITCHES ON THE FIRE

SPRINKLER FLOOR CONTROL VALVE ASSEMBLY.

142 PROVIDE NOTIFICATION APPLIANCE REMOTE POWER

SUPPLY/ TRANSPONDER.

144 PROVIDE FIRE ALARM AMPLIFIER PANEL.

148 PROVIDE SMOKE DAMPER WHERE DUCTS PENETRATE

THE SMOKE PARTITION. DUCT SMOKE DETECTORS

SHALL BE INSTALLED WITHIN 5 FEET OF DAMPERS.

154 ADDRESSABLE CONTROL MODULE AT LIGHTING

INVERTER FOR ACTIVATION OF EMERGENCY LIGHTING

CONTROL UPON FIRE ALARM SIGNAL PER NFPA 101 FOR

ILLUMINATION OF MEANS OF EGRESS. RE: ELECTRICAL

DRAWINGS FOR INVERTER LOCATIONS.

KEYNOTES

106 PROVIDE REMOTE TEST STATION WITH KEYSWITCH AND

LED INDICATOR.

116 PROVIDE RECESS MOUNTED LOCAL OPERATING

CONSOLE WITH MICROPHONE AND EMERGENCY AIR

DISTRIBUTION SHUTOFF SWITCH IN ACCORDANCE WITH

UFC 4-010-01 SECTION B-4.3.

121 SMOKE DETECTOR FOR PROTECTION OF PANELS.

122 PROVIDE SMOKE DETECTOR IN ELEVATOR LOBBY FOR

ELEVATOR RECALL.

123 PROVIDE DUCT SMOKE DETECTORS IN ALL SUPPLY

DUCTS FOR AHUS GREATER THAN 2,000 CFM, PROVIDE

DUCT SMOKE DETECTOR ON RETURN AND SUPPLY SIDE

OF AHUS OVER 15,000 CFM PER NFPA 90A AND UFC

3-600-01.

124 MONITOR FLOW AND TAMPER SWITCHES AT CONTROL

VALVE FOR SPRINKLER PIPING SERVING ELEVATOR

MACHINE ROOM.

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

FIRE SPRINKLER DESIGN CRITERIA

PATTERN OCCUPANCY SYSTEM

TYPE

DENSITY/

AREA

HOSE

ALLOWANCE

SPRINKLER

AREA OF

COVERAGE

SPRINKLER

K-FACTOR

(MIN.)

(NO

SHADING)

LIGHT HAZARD

(TYPICAL)

FOR CEILING

HEIGHTS UP TO 30 FT

WET

PIPE

SYSTEM

0.10

GPM/SF

OVER

MOST

REMOTE

1,500 SF

250 GPM 225 SF 5.6

ORDINARY HAZARD

(TYPICAL) FOR

CEILING HEIGHTS UP

TO 30 FT

0.20

GPM/SF

OVER

MOST

REMOTE

2,500 SF

250 GPM 130 SF 8.0

WET

PIPE

SYSTEM

FLOW

DURATION

60 MINUTES

60 MINUTES

1.5 2.51 2 3

G

F

E

C.5

C

G.5

3.30.20.5

D

D.2

CORR

STAIR 1

MAIN MECH

MAIN ELEC

158 HOH STUDIO

159A

HOH

SB STORAGE

M A

T C

H L

IN

E

B

F P

MECH YARD

100A

TRUE NORTH

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A

F R

C C

O N

S O

L

ID

A T

E D

M

IS

S

IO

N C

O M

P L

E X

P

H A

S E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V S

A R

O N

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

A

AREA A

KEY PLAN

PHASE 3PHASE 1

P R

O J E

C T

N U

M B

E R

U

H H

Z P

B C

D E

T B

D

FP111

F

IR

E P

R O

T E

C T

IO

N

P L A

N

L E

V E

L

A

R E

A A

R P

A R

K

J O

S T

W C

L A

Y

U H

H Z

F

P

KEYNOTES

045 NO SPRINKLER PROTECTION REQUIRED FOR

EXTERIOR MECHANICAL YARD.

GENERAL NOTES - FIRE SPRINKLER

A REFER TO SHEET GI002 AND GI003 FOR LIST OF

ABBREVIATIONS USED IN DRAWINGS. REFER TO

SHEET GI012 FOR ROOM SCHEDULE.

B REFER TO SHEET F-001 FOR ABBREVIATIONS,

SYMBOLS, AND GENERAL NOTES.

C REFER TO SHEET FP501 AND FP502 FOR FIRE

SPRINKLER DETAILS.

D REFER TO ARCHITECHTURAL REFLECTED

CEILING PLANS FOR COORDINATION WITH

LIGHTS, MECHANICAL DIFFUSERS, AND CEILING

GRID.

SCALE 1/8" = 1'-0"

A1 FIRE PROTECTION PLAN - LEVEL 1 - AREA A

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

PRINTING/WORK

ROOM

GRAPHICS

PA

DEP DIR

171G

PA DIR

171H

STG

VESTIBULE

LOBBY / STAIR 2

VIDEO STUDIO

STORAGE

170A

CONTROL

ROOM

EQUIP

ROOM

166E VIDEO

DUB

166A

PAI

166F

EDIT

166B

EDIT

166C

EDIT

166D

PA

CORR

101A

TRAINING

SE STG

102A

PAR DIV CH

171B

M A

T C

H L

IN

E

B

F P

MATCHLINE

B1 FP114

M A

T C

H L

IN

E

C

F P

PAO DIV CH

171C

PA STG

171D

SR

ENL ADV

171F

3.7 3.9 4 4.7 5 6 6.5 7 7.6 8

G

F

G.5

7.3

J

4.53.6

STORAGE

166G

ELEC (SB)

162A

PA DIR SUITE

171E

FIRE SPRINKLER DESIGN CRITERIA

PATTERN OCCUPANCY SYSTEM

TYPE

DENSITY/

AREA

HOSE

ALLOWANCE

SPRINKLER

AREA OF

COVERAGE

SPRINKLER

K-FACTOR

(MIN.)

(NO

SHADING)

LIGHT HAZARD

(TYPICAL)

FOR CEILING

HEIGHTS UP TO 30 FT

WET

PIPE

SYSTEM

0.10

GPM/SF

OVER

MOST

REMOTE

1,500 SF

250 GPM 225 SF 5.6

ORDINARY HAZARD

(TYPICAL) FOR

CEILING HEIGHTS UP

TO 30 FT

0.20

GPM/SF

OVER

MOST

REMOTE

2,500 SF

250 GPM 130 SF 8.0

WET

PIPE

SYSTEM

FLOW

DURATION

60 MINUTES

60 MINUTES

TRUE NORTH

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A

F R

C C

O N

S O

L

ID

A T

E D

M

IS

S

IO

N C

O M

P L

E X

P

H A

S E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V S

A R

O N

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

B

AREA B

KEY PLAN

P R

O J E

C T

N U

M B

E R

U

H H

Z P

A

C

ED

T B

D

FP112

F

IR

E P

R O

T E

C T

IO

N

P L A

N

L E

V E

L

A

R E

A B

R P

A R

K

J O

S T

W C

L A

Y

U H

H Z

F

P

SCALE 1/8" = 1'-0"

A1 FIRE PROTECTION PLAN - LEVEL 1 - AREA B

GENERAL NOTES - FIRE SPRINKLER

A REFER TO SHEET GI002 AND GI003 FOR LIST OF

ABBREVIATIONS USED IN DRAWINGS. REFER TO

SHEET GI012 FOR ROOM SCHEDULE.

B REFER TO SHEET F-001 FOR ABBREVIATIONS,

SYMBOLS, AND GENERAL NOTES.

C REFER TO SHEET FP501 AND FP502 FOR FIRE

SPRINKLER DETAILS.

D REFER TO ARCHITECHTURAL REFLECTED

CEILING PLANS FOR COORDINATION WITH

LIGHTS, MECHANICAL DIFFUSERS, AND CEILING

GRID.

KEYNOTES

034 SUGGESTED ROUTING OF 6 INCH WET PIPE

MAIN FROM STAIR 3 FLOOR CONTROL VALVE

ASSEMBLY SERVING LEVEL 1.

ARIMS: 200A Disposition: Maintain for 15yrs after construction.

W

2Q R

R

-0

VESTIBULE

TRAINING

SE

SGX

110C

SG

MED CONF

SG DIR SUITE

110E

SG DIR

110M

RR

117A

RPO

FMAH

DEP DIR

102C

SPT

102B

DIRECTOR

102D

SE STG

102A

SEF

102E

SEW

102F

SEG

102G

SGX DIV CH

110D

DEP DIR

110N

SR ENL ADV

110L

SGN

110F

DRUG

110G

SGS

110H

MATCHLINE

B1 FP114

M A

T C

H L

IN

E

A

F P

MATCHLINE

A1 FP112

7.6 8 9 9.5 10 11 11.5 12 12.5 13

G

F

G.5

J

12.6 13.1

H

G.6

FIRE SPRINKLER DESIGN CRITERIA

PATTERN OCCUPANCY SYSTEM

TYPE

DENSITY/

AREA

HOSE

ALLOWANCE

SPRINKLER

AREA OF

COVERAGE

SPRINKLER

K-FACTOR

(MIN.)

(NO

SHADING)

LIGHT HAZARD

(TYPICAL)

FOR CEILING

HEIGHTS UP TO 30 FT

WET

PIPE

SYSTEM

0.10

GPM/SF

OVER

MOST

REMOTE

1,500 SF

250 GPM 225 SF 5.6

ORDINARY HAZARD

(TYPICAL) FOR

CEILING HEIGHTS UP

TO 30 FT

0.20

GPM/SF

OVER

MOST

REMOTE

2,500 SF

250 GPM 130 SF 8.0

WET

PIPE

SYSTEM

FLOW

DURATION

60 MINUTES

60 MINUTES

TRUE NORTH

164 8268

SCALE: 1/8"=1'-0"

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

F Y

A

F R

C C

O N

S O

L

ID

A T

E D

M

IS

S

IO

N C

O M

P L

E X

P

H A

S E

R O

B

IN

S A

IR

F

O R

C E

B A

S E

G

E O

R G

IA

Louisville District ®

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

D R

A W

IN

G

C O

D E

T B

D

T B

D

A

U G

V S

A R

O N

I F

IL

E

N A

M E

L O

U

IS

V

IL

L E

D

IS

T R

U

IS

V

IL

L E

K

E N

T U

C K

Y

J A

C O

B S

E N

G

IN

E E

R

IN

G G

R O

U P

I N

C

M a in

S tr e e t, F o rt

W o rt h

T X

J A

C O

B S

N o

D

CERTIFIED FINAL DESIGN

KEY PLAN

C

AREA C

P R

O J E

C T

N U

M B

E R

U

H H

Z…