Drawings.pdf
PDF 24 MB Posted
- Solicitation number
- W912PQ-09-R-0013
About this file
Drawings
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Questions 3.docx | DOCX document | |
| W912PQ-09-R-0013-0003.doc | DOC document | |
| 50624 Addendum 2 Binder Drawings.pdf | ||
| FSS13960 NY5 Addendum 2 Specs.pdf | ||
| Questions Set 2.doc | DOC document | |
| Questions Set 1.doc | DOC document | |
| Option.pdf | ||
| W912PQ-09-R-0013-0002.doc | DOC document | |
| Pre-Proposal Slides1.pptx | PPTX presentation | |
| W912PQ-09-R-0013-0001.doc | DOC document | |
| ATTENDANCE SHEET.pdf | ||
| W912PQ-09-R-0013.doc | DOC document | |
| EXHIBIT A.doc | DOC document | |
| Exhibit D-E-F.doc | DOC document | |
| Exhibit B.doc | DOC document | |
| Exhibit C.doc | DOC document | |
| W912PQ-09-R-0013-0001.doc | DOC document | |
| 50624 Addendum 1 Binder.pdf | ||
| Specs.pdf | ||
| W912PQ-09-R-0013.docx | DOCX document |
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
mfernandez Stamp
CABINET UNIT HEATER SCHEDULE
NO. UH-1
LOCATION HEF SHELTER
TYPE ELECTRIC
RPM 1550
CFM 400
HP 1/125
MBTUH 11.2
ELECT. - V/PH/HZ 480/3/60
MANUFACTURER TRANE
MODEL NO. UHEC-033DACA
REMARKS 1
NOTES:
1. PROVIDE WITH DISCONNECT SWITCH WITH UNIT MOUNTED
LOW VOLTAGE TRANSFORMER AND THERMOSTAT
GENERATOR NUMBER HX-1 HX-2 HX-3 HX-4 HX-5 HX-6 HX-7 HX-8 HX-9 HX-10 HX-11 HX-12
FOAM DISCHARGE
(CFM)
11920 11920 11920 11920 11920 11920 11920 11920 11920 11920 11920 11920
DISCHARGE DIRECTION
(DOWN OR
HORIZONTAL
DOWN DOWN DOWN DOWN DOWN DOWN DOWN DOWN DOWN DOWN DOWN DOWN
DESIGN INLET
PRESSURE (PSIG)
60 60 60 60 60 60 60 60 60 60 60 60
FOAM SOLUTION FLOW
(GPM)
120 120 120 120 120 120 120 120 120 120 120 120
FOAM EXPANSION
RATIO
825 825 825 825 825 825 825 825 825 825 825 825
WEIGHT(LBS) 441 441 441 441 441 441 441 441 441 441 441 441
APPROVAL REQUIRED
FM AND/OR UL
LISTED
FM AND/OR
UL LISTED
FM AND/OR UL
LISTED
FM AND/OR
UL LISTED
FM AND/OR
UL LISTED
FM AND/OR UL
LISTED
FM AND/OR UL
LISTED
FM AND/OR
UL LISTED
FM AND/OR
UL LISTED
FM AND/OR
UL LISTED
FM AND/OR
UL LISTED
FM AND/OR
UL LISTED
MANUFACTURER CHEMGUARD CHEMGUARD CHEMGUARD CHEMGUARD CHEMGUARD CHEMGUARD CHEMGUARD CHEMGUARD CHEMGUARD CHEMGUARD CHEMGUARD CHEMGUARD MODEL NUMBER 15000WP 15000WP 15000WP 15000WP 15000WP 15000WP 15000WP 15000WP 15000WP 15000WP 15000WP 15000WP
HIGH EXPANSION FOAM GENERATORS SCHEDULE
PROPORTIONER NUMBER HXP-1 HXP-2 HXP-3 HXP-4 HXP-5 HXP-6
SIZE (INCHES) 4 4 4 4 4 4
PROPORTIONING
PERCENTAGE
2 2 2 2 2 2
USABLE FLOW RANGE 200-1600 200-1600 200-1600 200-1600 200-1600 200-1600
APPROXIMATE DESIGN
FLOW (GPM)
240 240 240 240 240 240
MINIMUM REQUIRED INLET
WATER PRESSURE (PSIG)
30 30 30 30 30 30
APPROVAL REQUIRED UL UL UL UL UL UL
MANUFACTURER CHEMGUARD CHEMGUARD CHEMGUARD CHEMGUARD CHEMGUARD CHEMGUARD
MODEL NUMBER EF10256 EF10256 EF10256 EF10256 EF10256 EF10256
HIGH EXPANSION FOAM PROPORTIONER SCHEDULE
VALVE SCHEDULE
VALVE TAG WP-1 DV-1 DV-2 DV-3 DV-4 DV-5 DV-6 AV-1 AV-2
SERVICE WET SPRINKLER
SYSTEM
FOAM/WATER
SYSTEM
FOAM/WATER
SYSTEM
FOAM/WATER
SYSTEM
FOAM/WATER
SYSTEM
FOAM/WATER
SYSTEM
FOAM/WATER
SYSTEM
FOAM/WATER
SYSTEM
FOAM/WATER
SYSTEM
TYPE RISER SWING
CHECK
FLOW CONTROL
DELUGE
FLOW CONTROL
DELUGE
FLOW CONTROL
DELUGE
FLOW CONTROL
DELUGE
FLOW CONTROL
DELUGE
FLOW CONTROL
DELUGE
ALARM CHECK
VALVE
ALARM CHECK
VALVE
TAG SIZE - IN. 6 4 4 4 4 4 4 4 4
PRESSURE RATING-PSI 250 250 250 250 250 250 250 250 250
MANUFACTURER VIKING VIKING VIKING VIKING VIKING VIKING VIKING VIKING VIKING
MODEL NUMBER EASY RISER -F-1 J-1 J-1 J-1 J-1 J-1 J-1 J-1 J-1
REMARKS NOTE 1 & 2 NOTE 1 & 2 NOTE 1 & 2 NOTE 1 & 2 NOTE 1 & 2 NOTE 1 & 2 NOTE 2 NOTE 2
NOTES:
1. VALVE TO BE PRESSURE REGULATING TYPE SET TO 80 PSI.
2. PROVIDE BRASS TRIM PIPING.
PANELBOARD NAME: EM1-EXISTING 65,000 RMS SYMMETRICAL A.I.C.
PANELBOARD TYPE: MAIN CIRCUIT BREAKER SURFACE MOUNTED, NEMA 1 ENCLOSURE 200 AMP TRIP MAIN BREAKER PANEL LOCATION: ELECTRIC RM ADMIN CORE, PODS 208Y/120 VOLTS, 3 PHASE, 4 WIRE 225 AMP MAINS
SUPPLIED FROM: EXISTING-PANEL DP2/ATS
CKT TRIP NO. WIRE / GND. GND. WIRE / NO. TRIP CKT.
NO. AMPS POLES CONDUIT WIRE LOAD SERVED LOAD
VA
Ø LOAD
VA
LOAD SERVED WIRE CONDUIT POLES AMPS NO.
1 100 3 4-#3/0 , 2 1/2" #6 PANEL EM2 - EXISTING 7154 A 577 RECEPTACLES-EXISTING #12 4-#12 , 3/4" 3 20 2 6434 B 577 4465 C 577 7 20 3 3-#12 , 3/4" #12 UNIT HEATER UH-4 - EXISTING 577 A 577 GFCI RECEPTACLES-EXISTING #12 4-#12 , 3/4" 3 20 8 577 B 577 577 C 577
13 20 3 3-#12 , 3/4" #12 577 A 577 UNIT HEATER UH-10 - EXISTING #12 3-#12 , 3/4" 3 20 14 577 B 577 577 C 577
19 15 2 2-#12 , 3/4" #12 UNIT HEATER UH-12 - EXISTING 577 A 500 FIRE ALARM PANEL #12 2-#12 , 3/4" 1 20 20
577 B 885 LIGHTING- EXISTING #12 2-#12 , 3/4" 1 15 22
577 C 590 LIGHTING- EXISTING #12 2-#12 , 3/4" 1 20 24
25 20 1 2-#12 , 3/4" #12 LIGHTING- EXISTING 826 A 413 LIGHTING- EXISTING #12 3-#12 , 3/4" 1 20 26 27 20 1 2-#12 , 3/4" #12 LIGHTING- EXISTING 554 B 552 UNIT HEATER UH-17 & 18 - EXISTING #12 2-#12 , 3/4" 1 20 28
29 20 1 SPARE C SPARE 1 20 30
31 20 1 SPARE A SPARE 1 20 32
33 20 1 SPARE B SPARE 1 20 34
35 20 1 SPARE C SPARE 1 20 36
37 20 1 SPARE A 936 NEW PANEL EM1A #8 4-#2 , 1 1/4" 3 125 38
39 20 1 SPARE B 1272
41 20 1 SPARE C 1992
TOTAL CONNECTED LOAD = 37 kVA X 95% DEMAND FACTOR = 35.2 kVA ESTIMATED DEMAND LOAD
PHASE BALANCE (KVA) - A: 13.3 , B: 13.2 , C: 10.5
PANELBOARD NAME: EM2-EXISTING 65,000 RMS SYMMETRICAL A.I.C.
PANELBOARD TYPE: MAIN CIRCUIT BREAKER SURFACE MOUNTED, NEMA 1 ENCLOSURE 100 AMP TRIP MAIN BREAKER
PANEL LOCATION: PODS #7 & #8, PODS 208Y/120 VOLTS, 3 PHASE, 4 WIRE 100 AMP MAINS
SUPPLIED FROM: EXISTING PANEL EM1
CKT TRIP NO. WIRE / GND. GND. WIRE / NO. TRIP CKT.
NO. AMPS POLES CONDUIT WIRE LOAD SERVED LOAD
VA
Ø LOAD
VA
LOAD SERVED WIRE CONDUIT POLES AMPS NO.
1 60 3 4-#3/0 , 2 1/2" #6 PANEL EM3 - EXISTING 4800 A 577 UNIT HEATER UH-14 - EXISTING #12 4-#12 , 3/4" 3 20 2 3700 B 577 1100 C 577 7 20 3 3-#12 , 3/4" #12 EJECTOR PUMP - EXISTING 500 A 577 UNIT HEATER UH-16 - EXISTING #12 4-#12 , 3/4" 3 20 8 500 B 577 500 C 577
13 20 1 2-#12 , 3/4" #12 500 A 200 RECIRC. PUMP #12 3-#12 , 3/4" 3 20 14
15 20 1 2-#12 , 3/4" #12 COMP. RECEPTACLES - EXISTING 540 B 540 COMP. RECEPTACLES - EXISTING
17 20 1 2-#12 , 3/4" #12 LIGHTING- EXISTING 944 C 767 LIGHTING- EXISTING
19 20 1 SPARE A SPARE 1 20 20
21 20 1 SPARE B SPARE 1 20 22
23 20 1 SPARE C SPARE 1 20 24
25 20 1 SPARE A SPARE 1 20 26
27 20 1 SPARE B SPARE 1 20 28
29 20 1 SPARE C SPARE 1 20 30
31 20 1 SPARE A SPARE 1 20 32
33 20 1 SPARE B SPARE 1 20 34
35 20 1 SPARE C SPARE 1 20 36
37 20 1 SPARE A SPARE 1 20 38
39 20 1 SPARE B SPARE 1 20 40
41 20 1 SPARE C SPARE 1 20 42
TOTAL CONNECTED LOAD = 18.1 kVA X 94% DEMAND FACTOR = 17 kVA ESTIMATED DEMAND LOAD
PHASE BALANCE (KVA) - A: 7.2 , B: 6.4 , C: 4.5
PANELBOARD NAME: P1B -EXISTING 22,000 RMS SYMMETRICAL A.I.C.
PANELBOARD TYPE: MAIN CIRCUIT BREAKER SURFACE MOUNTED, NEMA 1 ENCLOSURE 60 AMP TRIP MAIN BREAKER
PANEL LOCATION: POD , PODS 208Y/120 VOLTS, 3 PHASE, 4 WIRE 125 AMP MAINS
SUPPLIED FROM: PNL P1A/15kVA XFM/ - EXISTING
CKT TRIP NO. WIRE / GND. GND. WIRE / NO. TRIP CKT.
NO. AMPS POLES CONDUIT WIRE LOAD SERVED LOAD
VA
Ø LOAD
VA
LOAD SERVED WIRE CONDUIT POLES AMPS NO.
1 20 1 2-#12 , 3/4" #12 RECEPTACLES - EXISTING 360 A 360 RECEPTACLES -EXISTING #12 2-#12 , 3/4" 1 20 2 3 20 2 2-#12 , 3/4" #12 240V RECEPTACLE - EXSITING 180 B 1000 BORASCOPE - EXISTING #12 2-#12 , 3/4" 1 20 4
180 C 200 EYEWASH - EXISTING #12 2-#12 , 3/4" 1 20 6
7 20 1 2-#12 , 3/4" #12 WASTE PUMP - EXISTING 864 A 577 UNIT HEATER UH-1 - EXISTING #12 3-#12 , 3/4" 3 20 8
9 20 1 2-#12 , 3/4" #12 WASTE PUMP - EXISTING 864 B 577
11 20 1 2-#10 , 3/4" #10 NEW MECH RM RCPT (5) 900 C 577
13 20 1 SPARE A SPARE 1 20 14
15 20 1 SPARE B SPARE 1 20 16
17 20 1 SPARE C SPARE 1 20 18
19 20 1 SPARE A SPARE 1 20 20
21 20 1 SPARE B SPARE 1 20 22
23 20 1 SPARE C SPARE 1 20 24
TOTAL CONNECTED LOAD = 6.6 kVA X 86% DEMAND FACTOR = 5.7 kVA ESTIMATED DEMAND LOAD
PHASE BALANCE (KVA) - A: 2.2 , B: 2.6 , C: 1.9
PANELBOARD NAME: EM1A 22,000 RMS SYMMETRICAL A.I.C.
PANELBOARD TYPE: MAIN LUGS ONLY SURFACE MOUNTED, NEMA 1 ENCLOSURE
PANEL LOCATION: ELECTRICAL RM 116, PODS 208Y/120 VOLTS, 3 PHASE, 4 WIRE 125 AMP MAINS
SUPPLIED FROM: EM1(EXISTING)
CKT TRIP NO. WIRE / GND. GND. WIRE / NO. TRIP CKT.
NO. AMPS POLES CONDUIT WIRE LOAD SERVED LOAD
VA Ø LOAD
VA LOAD SERVED WIRE CONDUIT POLES AMPS NO.
1 20 1 2-#6 , 3/4" #6 FA POWER EXTENDER FAE #1 384 A 276 PANEL HEF #1 #6 2-#6 , 3/4" 1 20 2 3 20 1 2-#12 , 3/4" #12 FIRE ALARM PANEL FACP #2 720 B 276 PANEL HEF #2 #6 2-#6 , 3/4" 1 20 4 5 20 1 2-#12 , 3/4" #12 PANEL HEF #3 276 C 720 FIRE ALARM PANEL FACP #1 #6 2-#6 , 3/4" 1 20 6
7 20 1 2-#12 , 3/4" #12 PANEL HEF #4 276 A SPARE 1 20 8
9 20 1 2-#12 , 3/4" #12 PANEL HEF #5 276 B SPARE 1 20 10
11 20 1 2-#12 , 3/4" #12 PANEL HEF #6 276 C 720 FIRE ALARM PANEL FACP #3 #6 2-#6 , 3/4" 1 20 12
13 15 1 SPARE A SPARE 1 20 14
15 15 1 SPARE B SPARE 1 20 16
17 15 1 SPARE C SPARE 1 20 18
19 1 A 1 20 21 1 B 1 22 23 1 C 1 24
TOTAL CONNECTED LOAD = 4.2 kVA X 100% DEMAND FACTOR = 4.2 kVA ESTIMATED DEMAND LOAD
PHASE BALANCE (KVA) - A: 0.9 , B: 1.3 , C: 2
PANELBOARD NAME: P1A -EXISTING 42,000 RMS SYMMETRICAL A.I.C.
PANELBOARD TYPE: MAIN CIRCUIT BREAKER SURFACE MOUNTED, NEMA 1 ENCLOSURE 100 AMP TRIP MAIN BREAKER
PANEL LOCATION: POD , PODS 480Y/277 VOLTS, 3 PHASE, 4 WIRE 125 AMP MAINS
SUPPLIED FROM: DP1 - EXISTING
CKT TRIP NO. WIRE / GND. GND. WIRE / NO. TRIP CKT.
NO. AMPS POLES CONDUIT WIRE LOAD SERVED LOAD
VA
Ø LOAD
VA
LOAD SERVED WIRE CONDUIT POLES AMPS NO.
1 20 3 3-#12 , 3/4" #12 UPWARD ACTING DOOR -EXISTING 3187 A 292 ROLL-UP DOOR - EXISTING #12 3-#12 , 3/4" 3 20 2 3187 B 292 3187 C 292 7 20 1 SPARE A 2161 15kVA XFMR/PNL P1B- EXISTING #10 3-#10 , 3/4" 3 25 8
9 20 1 SPARE B 2621
11 20 1 SPARE C 1857
13 20 1 2-#12 , 3/4" HIGH BAY LIGHTING - EXISTING 3200 A SPARE 1 20 14
15 20 1 2-#12 , 3/4" #12 NEW MECH RM LIGHTING 210 B SPARE 1 20 16
17 20 1 2-#10 , 3/4" #10 NEW PERIMETER LIGHTING 849 C SPARE 1 20 18
19 20 1 SPARE A 1667 NEW MECH. RM. SPACE #12 3-#12 , 3/4" 3 20 20
21 20 1 SPARE B 1667 HEATER UH-1
23 20 1 SPARE C 1667
TOTAL CONNECTED LOAD = 26.3 kVA X 96% DEMAND FACTOR = 25.3 kVA ESTIMATED DEMAND LOAD
PHASE BALANCE (KVA) - A: 10.5 , B: 8 , C: 7.9
| 50624 100% Mech Binder |
| 50624M101.pdf |
| 50624 Const-100-Fire Binder |
| 50624 Const-100-Fire Binder.pdf |
| 50624FD101.pdf |
| 50624FD102.pdf |
| 50624FP101.pdf |
| 50624FP102.pdf |
| 50624FP103.pdf |
| 50624FP201.pdf |
| 50624FP301.pdf |
| 50624FP401.pdf |
| 50624.struc.IFC 6122009 |
| 50624S001 |
| 50624S101 |
| 50624S501 |
| 50624-100% Arch Binder |
| 50624A001 |
| 50624A101 |
| 50624A102 |
| 50624A301 |
| 50624-100% Civil Binder |
| 50624 Construction Elec Binder.pdf |
| 50624E001 E001 (1) |
| 50624E002 E002 (1) |
| 50624E003 E003 (1) |
| 50624E004 E004 (1) |
| 50624E101 E101 (1) |
| 50624E301 ED301 (1) |
| 50624E302 ED302 (1) |
| 50624E303 ED303 (1) |
| 50624E304 ED304 (1) |
| 50624E305 E305 (1) |
| 50624E306 E306 (1) |
| 50624E307 E307 (1) |
| 50624E308 E308 (1) |
| 50624E601 E601 (1) |
| 50624E602 E602 (1) |
| 50624E603 E603 (1) |
| 50624E604 E604 (1) |
| 50624E605 E605 (1) |
| 50624E901 E901 (1) |
| 50624E902 E902 (1) |
| 50624E903 E903 (1) |