W912PP-16-R-0005-Drawings-Shts-92-264_10-Feb-16.pdf

PDF 44 MB Posted

Attached to
CONSTRUCT PUMPHOUSE AND FUEL STORAGE, CANNON AIR FORCE BASE
Solicitation number
W912PP-16-R-0005
Issued by

About this file

W912PP-16-R-0005 DRAWING SHEETS 92-264

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N T

S

S O

L I C

I T

A T

I O

N

N

O

F I L E

A M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

U M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

C

O

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

S

D

F

E

L

S

T O

R A

G E

C A

N N

B

N

W

M

X

I C

O

X

P R

O J E

D

E S

C

PLUMBING

VENT

SANITARY

SS

WF

WH

WALL FAUCET

WALL HYDRANT

DOMESTIC HOT WATER

DOMESTIC COLD WATER

A

C

D

A

A-

B

A

A-

A

ROOM NUMBER

DOOR NUMBERS

CLEAN OUT

FLOOR DRAIN

CO

FD

CO

ST

ST

RL

RD

RS

CWS

CWR

CR

THERMOSTATT

C

FOR ADDITIONAL LEGEND

WALL CLEAN OUT

STORM DRAIN BELOW FLOOR

CONDENSER WATER SUPPLY

CONDENSER WATER RETURN

REFRIGERANT STRAINER

CHILLED WATER RETURN

CHILLED WATER SUPPLY

REFRIGERANT SUCTION

REFRIGERANT DISCHARGE (HOT GAS)

REFRIGERANT LIQUID

THERMOSTATIC EXPANSION VALVE

STORM DRAIN ABOVE FLOOR

SEE TEMPERATURE CONTROL DRAWINGS

REFRIGERATION

TEMPERATURE CONTROLS

SECTION NUMBER

SHEET NUMBER OF DWG.

OF ELEV. ON PLAN

DIRECTION OF SIGHT

ELEV. IS SHOWN

OF ELEV. ON PLAN

DIRECTION OF SIGHT

WHERE ELEV. IS SHOWN *

NOTE: LOCATION OF DWG. WHERE

COLUMN LINES NUMBER-LETTER (OPPOSITE DIR.)

SHEET NUMBER OF DRAWING

WHERE SECTION IS SHOWN *

STANDARD NORTH ARROWS

SECTION IDENTIFICATION

ELEVATION IDENTIFICATION

ARCHITECTURAL SYMBOLS

A

MATCH LINE

WINDOW TYPES

CENTER LINE

X

S

N

OA

E

H

P

PB

HUMIDITY SENSOR

PRESSURE SENSOR

EMCS SENSOR

MANUAL OVER-RIDE SWITCH

NIGHT THERMOSTAT

TEMPERATURE SENSOR

OUTDOOR AIR THERMOSTAT

DIRECTION OF SIGHT OF PHOTOGRAPH

WALL AND PARTITION TYPES

DUCTWORK

20 x 12 RG

20 x 12 SG

700 CFM

20 x 12 GR

20 x 12 SR

700 CFM

700 CFM

20 O/

700 CFM

700 CFM

MECHANICAL LEGEND

DOOR GRILLE

12 x 12

700 CFM

DG

12 x 6

20 x 12

R

FIRE DAMPER:

MOD

SEC.

VD

OR

FD

AD

SD

AD

AD

AS INDICATED

EARTH

CONCRETE

GRAVEL

BRICK

METAL

PLYWOOD

WOOD (FINISH)

WOOD (ROUGH)

AS INDICATED

CRUSHED ROCK

PLASTER

GLASS (ELEVATION)

BLANKET INSULATION

RIGID INSULATION

GYPSUM WALLBOARD

WOOD STUD PARTITION

CONCRETE MASONRY UNITS (PLAN)

CONCRETE MASONRY UNITS (SECTION)

GLASS (LARGE SCALE SECTION)

METAL STUD PARTITION

ARCHITECTURAL LEGEND

SUPPLY GRILLE (SG)

FLOW DIRECTION

FLOW DIRECTION

DIRECTION OF FLOW

SPLITTER DAMPER

ACCESS PANEL (AP)

ACCESS DOOR (AD)

FLEXIBLE DUCT

TURNING VANES

SMOKE DAMPER

(TYPE AS SPECIFIED) INDICATE

SUPPLY OUTLET, CEILING, RECTANGULAR

(TYPE AS SPECIFIED) INDICATE

SUPPLY OUTLET, CEILING ROUND

CEILING (INDICATE TYPE)

EXHAUST OR RETURN AIR INLET

+ INTEGRAL VOL. CONTROL)

SUPPLY REGISTER (SR) (A GRILLE

GRILLE (NOTE AT FLR. OR CLG.)

RETURN (RG) OR EXHAUST (EG)

VENTILATOR-SUPPLY (SRV)

POWER OR GRAVITY ROOF

VENTILATOR-EXHAUST (ERV)

POWER OR GRAVITY ROOF

UNIT HEATER (HORIZONTAL)

PARALLEL BLADE DAMPERS

2ND FIGURE, SIDE NOT SHOWN)

DUCT (1ST FIGURE, SIDE SHOWN

FLAT ON TOP OR F.O.B. FLAT

TRANSITIONS: GIVE SIZES. NOTE F.O.T.

IN DIRECTION OF AIR FLOW

INCLINED RISE (R) OR DROP (D) ARROW

DUCT SECTION (EXHAUST OR RETURN)

DUCT SECTION (SUPPLY)

OPPOSED BLADE DAMPERS

SHOW HORIZ. POS.

SHOW VERTICAL POS.

AUTOMATIC DAMPERS MOTOR OPERATED

VOLUME DAMPER MANUAL OPERATION

& RETURN (NO SPLITTER)

STANDARD BRANCH FOR SUPPLY

FLEXIBLE CONNECTION

ON BOTTOM IF APPLICABLE

HOSE BIBBHB

A

A-

M

WATER METER

CONDENSATE DRAIN

CD

PLASTER

A-001A

R

A

A D

W G

G E

N E

R A

L

L

E G

E N

D

K F

B

R E

D E

H O

E

P P

R

A F

B U

I L D

I N

G

A

T

R

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

PLAN NOTES:

1. SEE SHEET AE303A FOR WALL TYPES.

2. ALL INTERIOR WALLS ARE WALL TYPE "1" UNLESS OTHERWISE NOTED.

3. MCJ - SEE DETAIL 5 / AE603A.

4. FEC - SEE DETAIL 6 / AE603A.

5. FEB ON PLAN INDICATES FIRE EXTINGUISHER BRACKET WITH

EXTINGUISHER.

6. ALL WALLS ARE EITHER 90° OR 45° UNLESS OTHERWISE NOTED.

7. CG ON PLAN INDICATES CORNER GUARDS.

8. BUILDING DIMENSIONS SHOWN AT EXTERIOR OF BUILDING ARE TO THE

OUTSIDE FACE OF VENEER CMU AT LOWER PORTION OF WALL.

9. PROVIDE FIRE TREATED 2X6 OR LARGER WOOD BLOCKING IN WALLS AS

REQUIRED TO SUPPORT TV ROUGH IN'S. VERIFY LOCATIONS & SIZES

(INCLUDING MOUNTING HEIGHTS) WITH OWNER PRIOR TO INSTALLATION

OF WOOD BLOCKING.

POL OPS BUILDING GENERAL NOTES:

1. BUILDING ELEVATION: POL OPERATION BUILDING FINISH FLOOR ELEV EQUALS 4281.00 ON CIVIL PLAN EQUALS FINISH FLOOR

ELEV 100'-0" ON ARCHITECTURAL PLANS.

2. ALL DIMENSIONS ARE TO FACE OF MASONRY OR TO FACE OF STUD UNLESS OTHERWISE NOTED.

3. PROVIDE FIRE TREATED 2X6 OR LARGER WOOD BLOCKING IN STUD WALLS AND FURRING SPACES AS REQUIRED FOR

MOUNTING OF ALL WALL SUPPORTED ITEMS. WHETHER OR NOT DETAILED ON THE DRAWINGS, THE CONTRACTOR SHALL

COORDINATE AND INSTALL ALL STIFFENERS, BRACING, BACK-UP PLATES, AND SUPPORTING BRACKETS AS REQUIRED FOR THE

INSTALLATION OF CASEWORK AND WALL MOUNTED OR SUSPENDED MECHANICAL, ELECTRICAL, OR MISC. EQUIPMENT. THESE

ITEMS INCLUDE BUT ARE NOT LIMITED TO DOOR WALL STOPS, FIRE EXTINGUISHER CABINETS, BASE CABINETS, CONTROL

PANELS, WATER COOLERS, MIRRORS, SOAP DISPENSERS, PAPER TOWEL DISPENSERS, NAPKIN DISPOSAL, TOILET PAPER

DISPENSERS, SIGNAGE, FIRE ALARM PANELS AND OTHER CONTROL PANELS, ETC.

4. FLOOR COVERING CHANGES SHALL OCCUR UNDER A DOOR UNLESS NOTED OR INDICATED OTHERWISE.

5. SEE STRUCTURAL FOUNDATION PLANS FOR DIMENSION AND DETAILS OF SLAB DEPRESSION, THICK-END SLABS, STRUCTURAL

STOOPS, EQUIPMENT PADS, CABLE TRENCHES, AND PIPE MOUNTS, ETC.

6. COUNTER TOPS AND BACK SPLASHES AT CABINETS SHALL BE CAULKED. BACK SPLASHES ARE TO BE SET IN A BED OF CAULK

WHERE IT MEETS THE COUNTER TOP. JOINT AT WALL SHALL BE CAULKED AFTER THE BACK SPLASH IS INSTALLED.

7. CONTRACTOR SHALL INSULATE THE AREA BETWEEN THE TOP OF THE EXTERIOR WALLS AND THE METAL ROOF DECK ON ANY

PERIMETER WALLS OR VESTIBULES WALLS WHERE A VOID EXISTS WITH A URETHANE FOAM INSULATION. ALSO FILL ALL OTHER

VOIDS IN THE THERMAL / INSULATION ENVELOPE OF THE BUILDING WITH THIS URETHANE FOAM INSULATION.

MECH

COMM

MEN

WOMEN

AREA

OPEN OFFICE

OFFICE

RCC

CUST

4'-0" 2'-8" 4'-0"

6'-0" 9'-8" 3'-4"

17'-2 1/2" 15'-9 1/4"

14'-1 1/4" 19'-1"

11'-8 1/4"

7'-3"

7'-2 3/4"

7'-4 1/2"

21'-3 1/2"

6'-10 1/4"

STRUCT

STOOP

STRUCT

STOOP

E W

C

A

A

A

B

VENDING

MACHINE (NIC)

REFR

(NIC)

METAL

SHELF

(NIC)

MOP SINK -

SEE MECH

WALL-MOUNTED

FLAT PANEL TV

W/ BRACKET (NIC)

- PROVIDE BLKG

WITHIN STUD

SPACE

BUILDING

IDENTIFICATION

SIGN - SEE

DETAIL 1/AE303A

LOCKER

UNITS

LOCKER

UNITS

SHOWER UNIT W/

SWING DOOR

SHOWER UNIT W/

SWING DOOR

44'-0"

44'-0"

13'-0" 12'-0"

4'-0"

4'-0"

4'-0"

4'-0"

ROOF

OVERHANG

ABOVE

CONC

SPLASHBLOCK

211 SQ FT

BUILDING "A" SQUARE FOOTAGE:

555 SQ FT

102 RCC

100 OPEN OFFICE AREA

103 WOMEN 105 SQ FT

TOTAL NET AREA 1525 SQ FT

TOTAL GROSS AREA 1817 SQ FT

105 SQ FT104 MEN

130 SQ FT105 COMM

171 SQ FT101 OFFICE

224 SQ FT106 MECH

24 SQ FT107 CUST

25'-4"

STEEL COLUMN

- SEE STRUCT

LOUVER IN

SOFFIT ABOVE -

SEE MECH

LOUVER IN

SOFFIT ABOVE -

SEE MECH

MCJ

MCJ

MCJ

MCJ

FD

FD

FD

FLOOR SINK -

SEE MECH

A

MCJ

MCJ

LOUVER IN

SOFFIT ABOVE -

SEE MECH

ROOF

OVERHANG

ABOVE

CONC

SPLASHBLOCK

STRUCT

STOOP

F E

C

FEB

FEB

CONC

SPLASHBLOCK

CONC

SPLASHBLOCK

4'-6 1/2"3'-0"

5 3/4"

3'-1"

3'-1"

1'-2 3/8"

CG

CG

CG

1 HR RATED

WALLS

1 HR RATED

WALL

1 HR RATED

WALLS

ROOM IDENTIFICATION

SIGNS - SEE DETAIL

3/AE303A

ROOM

SIGN 101

ROOM

SIGN 102

LEGEND: WALL TYPES

3 5/8" OR 4" METAL STUDS AT

16" O.C. W/ 5/8" GYPSUM

WALLBOARD EACH SIDE (SEE

INDICATED WALL TYPE FOR

STUD DEPTH REQUIRED)

(MCJ) MASONRY CONTROL

JOINT LOCATION

PORTLAND CEMENT STUCCO

SYSTEM OVER 3" RIGID

INSULATION (R-18) OVER 8" CMU

W/ 5/8" GYPSUM BOARD OVER

2 1/2" METAL STUDS @ 16" O.C.

W/ 2 1/2" BATT INSULATION (R-8)

4'-0"

4'-0"

6'-8"

LOUVER IN

SOFFIT ABOVE -

SEE MECH

8'-0"

CG

CG

AE202A

AE301A

AE201A

AE304A

AE301A

AE201A

AE202A

ROOM SIGN 107

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

X

P R

O J E

D

E S

C

TRUE

NORTH

SCALE: 1/4" = 1'-0"

2' 4'0 8'

SCALE 1/4 INCH = 1 FOOT

FLOOR PLAN

PLAN

NORTH

AE101A

R

A

E

A D

W G

F L O

P

A

N

K F

B

R E

D E

H O

E

P P

R

A F

B U

I L D

I N

G

A

T

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

MECH

COMM

MEN

WOMEN

AREA

OPEN OFFICE

OFFICE

RCC

CUST

CJ

CJ

SLOPED GWB

LEGEND:

RETURN AIR GRILL

OR EXHAUST GRILL

(SEE MECHANICAL)

2'-0" x 4'-0" LIGHT FIXTURE

(SEE ELECTRICAL)

2'-0" x 2'-0"

ACOUSTICAL

CEILING TILE

ONE-HOUR FIRE RATED WALL

(TO STRUCTURE ABOVE)

UL DESIGN NO. - U465 1-HR

RECESSED CAN LIGHT FIXTURE

(SEE ELECTRICAL)

GYPSUM WALL

BOARD CEILING

SUPPLY AIR DIFFUSER

(SEE MECHANICAL)

1'-0" x 4'-0" LIGHT FIXTURE

(SEE ELECTRICAL)

2'-0" x 4'-0" EMERGENCY

LIGHT FIXTURE

(SEE ELECTRICAL)

SOFFIT VENT

(SEE MECHANICAL)

SCALE: 1/4" = 1'-0"

2' 4'0 8'

SCALE 1/4 INCH = 1 FOOT

REFLECTED CEILING PLAN

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

X

P R

O J E

D

E S

C

AE102A

R

A

E

A D

W G

R E

F L E

C T

I L

I N

G

P

L A

N

K F

B

R E

D E

H O

E

P P

R

A F

B U

I L D

I N

G

A

T

TRUE

PLAN

NORTH

R E

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

OVERHANG

BUILDING LINE

BELOW

BUILDING LINE

BELOW

SLOPE

4/12 PITCH

STANDING SEAM

METAL ROOF

PREFINISHED

6"x6" METAL

GUTTER

PREFINISHED 6"x6"

METAL GUTTER

PREFINISHED

METAL COPING

PARAPET

PREFINISHED

METAL RIDGE CAP

PREFINISHED

METAL COPING

PARAPET

SLOPE

4/12 PITCH

VTR - SEE

MECH

OVERHANG

4"x5"

DOWNSPOUT

LOCATION

44'-0"

41'-7 3/4"

3'-0"35'-7 3/4"3'-0"

4"x5"

DOWNSPOUT

LOCATION

4"x5"

DOWNSPOUT

LOCATION

4"x5"

DOWNSPOUT

LOCATION

FLUE - SEE

MECH

AE103A

AE103A

AE103A

NEOPRENE GASKET

UNDER EACH

FASTENER HEAD

STUFF W/ BATT

INSULATION

METAL CLOSURE

PLATE CONT

STEEL BEAM (SEE

STRUCTURAL DWGS)

NOTE:

SEE ELECTRICAL DWGS FOR

LOCATIONS OF AIR TERMINALS

RIGID ROOF INSULATION

(R-38)

AIR TERMINAL AS

REQUIRED

BASE PLATE - PAINT TO

MATCH ROOF

POURABLE SEALANT AS

RECOMMENDED BY

ROOF MFR

RIDGE CAP

PANEL CLOSURE

W/ SEALANT

STANDING SEAM

METAL ROOFING

"Z" SUBPURLIN

STEEL DECK

STEEL JOIST

(SEE STRUCT

DWGS)

FLEXIBLE EPDM PIPE

FLASHING BOOT

METAL BASE RING

CONTOURED TO

ROOF PROFILE

STANDING SEAM

METAL ROOF

BASE DIA VARIES W/ PIPE DIA

RIGID ROOF

INSULATION

(R-38)

W

P

I P

E

D

I

FLASHING

EXTENDS 2'-0"

IN ALL

DIRECTIONS

PIPE THRU ROOF

V A

R I E

S

M

I N

SCALE: 1/4" = 1'-0"

2' 4'0 8'

SCALE 1/4 INCH = 1 FOOT

ROOF PLAN

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

X

P R

O J E

D

E S

C

AE103A

R

A

E

A D

W G

R O

A

T

A I L S

K F

B

R E

D E

H O

E

P P

R

A F

B U

I L D

I N

G

A

T

TRUE

PLAN

NORTH

SCALE 1 1/2 INCH = 1 FOOT

TYPICAL RIDGE CAP DETAIL

SCALE 1 1/2 INCH = 1 FOOT

TYPICAL VTR/FLUE DETAIL

SCALE: 1 1/2" = 1'-0"

4" 8"0 1'-4"

V A

R I E

S

R E

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

FINISHED FLOOR

ELEV. =100'-0"

EAVE HEIGHT

ELEV. =112'-6"

BOTTOM OF METAL SOFFIT

ELEV. =110'-1 1/2"

STANDING SEAM

METAL ROOF

METAL STANDING SEAM

FASCIA PANEL

RIDGE CAP

FOUNDATION -

SEE STR

6"x6" METAL GUTTER

CEMENT PLASTER

STUCCO FINISH, TYP

BUILDING IDENTIFICATION SIGN -

SEE DETAIL 1/AE303A AND

SPECIFICATIONS. CONFIRM SIGN

LOCATION W/ CONTRACTING OFFICER

C E

N T

E R

OPEN OFFICE

AREA

METAL COPING @

TOP OF PARAPET

PARAPET HIGH PT

ELEV. =120'-5 1/4"

TOP OF ROOF

ELEV. =119'-7 1/4"

STRUCT STOOP -

SEE STR

STUCCO CONTROL

JT, TYP

MF-2SSM-1

MF-1

MF-3

MF-2

MFP-1

MF-4

P-1

MF-1

ALUM-1

STC-1

PRECAST SILL

ROCKFACE CMU

CMU-1

MCJMCJ

CONC

SPLASHBLOCK -

SEE DETAIL

9/AE603A (TYP)

5"x4" METAL

DOWNSPOUT

(TYP)

LIGHT FIXTURE -

SEE ELEC

T

Y P

FOUNDATION -

SEE STR

CEMENT PLASTER

STUCCO FINISH, TYP

METAL COPING @

TOP OF PARAPET

PARAPET HIGH PT

ELEV. =120'-5 1/4"

PARAPET LOW PT

ELEV. =113'-4 1/2"

(TYP)

STRUCT STOOPS -

SEE STR

STUCCO CONTROL

JTS, TYP

P-1

P-1

STC-1

MF-1

COMMUNICATIONS

C E

N T

E R

MECHANICAL ROOM

C E

N T

E R

FINISHED FLOOR

ELEV. =100'-0"

ROCKFACE CMU

PRECAST SILL

CMU-1

MCJ

ROOM IDENTIFICATION SIGN -

SEE DETAIL 3/AE303A AND

SPECIFICATIONS. CONFIRM SIGN

LOCATION W/ CONTRACTING OFFICER

ROOM IDENTIFICATION SIGN -

SEE DETAIL 3/AE303A AND

SPECIFICATIONS. CONFIRM SIGN

LOCATION W/ CONTRACTING OFFICER

LIGHT FIXTURE -

SEE ELEC, TYP

SCALE: 1/4" = 1'-0"

2' 4'0 8'

SCALE 1/4 INCH = 1 FOOT

EAST ELEVATION

SCALE 1/4 INCH = 1 FOOT

SOUTH ELEVATION

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

X

P R

O J E

D

E S

C

FINISH LEGEND

ALUM-1 ALUMINUM WINDOWS - COLOR: SEE SPEC

SECTION 090690 COLOR SCHEDULE.

CMU-1 ROCKFACE 4" CMU VENEER PRODUCT AND

MORTAR COLOR TO MATCH ROCKFACE CMU

COLOR: SEE SPEC SECTION 090690 COLOR

SCHEDULE.

MF-1 PREFINISHED METAL COPING, FLASHING, AND

TRIM - COLOR: SEE SPEC SECTION 090690

COLOR SCHEDULE.

MF-2 PREFINISHED METAL FLASHING & TRIM - COLOR

TO MATCH ROOF COLOR: SEE SPEC SECTION

090690 COLOR SCHEDULE.

MF-3 PREFINISHED METAL GUTTER - COLOR TO MATCH

ROOF COLOR: SEE SPEC SECTION 090690 COLOR

SCHEDULE.

MF-4 PREFINISHED METAL DOWNSPOUT - COLOR TO

MATCH ROOF COLOR: SEE SPEC SECTION 090690

COLOR SCHEDULE.

MFP-1 PREFINISHED METAL FASCIA PANEL - COLOR TO

MATCH ROOF COLOR: SEE SPEC SECTION 090690

COLOR SCHEDULE.

P-1 PAINTED HOLLOW METAL DOOR & FRAME - SEE

SPEC SECTION 090690 COLOR SCHEDULE.

SSM-1 STANDING SEAM METAL ROOFING - COLOR TO

MATCH ROOF COLOR: SEE SPEC SECTION 090690

COLOR SCHEDULE.

STC-1 STUCCO - COLOR: SEE SPEC SECTION 090690

COLOR SCHEDULE, FINISH: MEDIUM DASH.

AE201A

R

A

E

A D

W G

E L E

V A

T I O

N S

K F

B

R E

D E

H O

E

P P

R

A F

B U

I L D

I N

G

A

T

ADDITIONAL EXTERIOR FINISH NOTES:

LOUVER AND MISCELLANEOUS ITEMS LOCATED IN STUCCO

WALLS: PAINT COLOR TO MATCH STUCCO WALL COLOR.

SEE SPEC SECTION 090690 COLOR SCHEDULE.

FOR ADDITIONAL COLOR INFORMATION, SEE COLOR

SCHEDULE WITHIN SPEC SECTION 090690.

A

B

R E

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

FINISHED FLOOR

ELEV. =100'-0"

EAVE HEIGHT

ELEV. =112'-6"

BOTTOM OF METAL SOFFIT

ELEV. =110'-1 1/2"

STANDING SEAM

METAL ROOF

METAL STANDING SEAM

FASCIA PANEL

FOUNDATION -

SEE STR

6"x6" METAL GUTTER

CEMENT PLASTER

STUCCO FINISH, TYP

METAL COPING @

TOP OF PARAPET

STUCCO CONTROL

JT, TYP

RIDGE CAP

MF-2SSM-1

MF-1

MF-1

STC-1

MF-2

MF-3

MFP-1

MF-4

TOP OF ROOF

ELEV. =119'-7 1/4"

PARAPET HIGH PT

ELEV. =120'-5 1/4"

ROCKFACE CMU

PRECAST SILL

CMU-1

MCJMCJ

5"x4" METAL

DOWNSPOUT

(TYP)

CONC

SPLASHBLOCK -

SEE DETAIL

9/AE603A (TYP)

PRECAST SILL

FINISHED FLOOR

ELEV. =100'-0"

PARAPET LOW PT

ELEV. =113'-4 1/2"

FOUNDATION -

SEE STR

CEMENT PLASTER

STUCCO FINISH, TYP

METAL COPING @

TOP OF PARAPET

(TYP)

STUCCO CONTROL

JTS, TYP

PRECAST SILL

STC-1

MF-1

ALUM-1

ALUM-1

PARAPET HIGH PT

ELEV. =120'-5 1/4"

ROCKFACE CMU

CMU-1

MCJ

T

Y P

SCALE: 1/4" = 1'-0"

2' 4'0 8'

SCALE 1/4 INCH = 1 FOOT

WEST ELEVATION

SCALE 1/4 INCH = 1 FOOT

NORTH ELEVATION

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

X

P R

O J E

D

E S

C

AE202A

R

A

E

A D

W G

E L E

V A

T I O

N S

K F

B

R E

D E

H O

E

P P

R

A F

B U

I L D

I N

G

A

T

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

TOP OF WALL

ELEV. VARIES

FINISH FLOOR

ELEV. =100'-0"

TOP OF

ROCKFACE CMU

ELEV. =103'-2"

BOT OF METAL DECK

ELEV. VARIES

ROCKFACE CMU

8" CMU

PORTLAND CEMENT

STUCCO SYSTEM

METAL COPING

(BEYOND)

STANDING SEAM

METAL ROOF

CONCRETE FOUNDATION -

SEE STRUCTURAL

ALUM FRAME

PRECAST CONCRETE

SILL

OFFICE

OPEN OFFICE

AREA

MECH

ATC

GWB

8" CMU

AE302A

AE302A

GWB OVER

METAL STUDS

EAVE HEIGHT/TOP OF CMU

ELEV. =112'-6"

FINISH FLOOR

ELEV. =100'-0"

BOT OF SOFFIT

ELEV. =110'-1 1/2"

TOP OF ROCKFACE CMU

ELEV. =103'-2"

ROCKFACE CMU

8" CMU

VENTED METAL

SOFFIT PANELS

PORTLAND CEMENT

STUCCO SYSTEM

METAL COPING

(BEYOND)

METAL STANDING

SEAM FASCIA PANEL

STANDING SEAM

METAL ROOF

4"x5" METAL

DOWNSPOUT

6"x6" METAL GUTTER

CONCRETE SPLASHBLOCK

CONCRETE FOUNDATION -

SEE STRUCTURAL

ALUM FRAME

OPEN OFFICE

AREA

MEN

ATC

AE301A

AE302A

GWB OVER

MET STUDS

8" CMU

CONCRETE FLOOR ON

VAPOR BARRIER

5/8" GWB OVER

2 1/2" METAL STUDS @

16" OC WITH

2 1/2" BATT INSUL (R-8)

STANDING SEAM

METAL ROOFING

RIGID ROOF

INSULATION (R-38)

METAL DECKING

3" CAVITY WALL

INSULATION (R-18)

METAL FASCIA PANELS ON

5/8" GLASS-MAT GYPSUM

SHEATHING BOARD

METAL DOWNSPOUT

MET GUTTER

FOUNDATIONS -

SEE STR

CONCRETE

SPLASH BLOCK

VENTED METAL SOFFIT

PANELS OVER 3 5/8" GALV

METAL FRAMING

EAVE HEIGHT

ELEV. =112'-6"

BOT OF SOFFIT

ELEV. =110'-1 1/2"

TOP OF CMU

ELEV. =112'-6"

FINISH FLOOR

ELEV. =100'-0"

PORTLAND CEMENT STUCCO

SYSTEM OVER GYPSUM

SHEATHING

4" ROCKFACE CMU

STEEL JOIST - SEE

STRUCT

SUSPENDED

ACOUSTIC TILE

CEILING

PRE-CAST SILL

SEALANT

FLUID-APPLIED AIR

BARRIER

THRU-WALL FLASHING w/

WEEPS @ 24" OC

10" HIGH DRAINAGE

WALL SYSTEM

1/2" COMPRESSIBLE

FILLER & SEALANT

2" PERIMETER

INSULATION

SPRAY-ON FOAM

THERMAL INSULATION

TO FILL ALL VOIDS IN

WALLS & ROOF

PREFIN MET COPING (BEYOND)

FACE OF STUCCO WALL

(BEYOND)

FACE OF CMU WALL (BEYOND)

8"

SCALE: 3/4" = 1'-0"

8" 1'-4"0 2'-8"

SCALE 1/4 INCH = 1 FOOT

BUILDING SECTION

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

X

P R

O J E

D

E S

C

AE301A

R

A

E

A D

W G

B U

I L D

I N

G

S

E C

T I O

L L

S E

C T

I O

N

K F

B

R E

D E

H O

E

P P

R

A F

B U

I L D

I N

G

A

T

SCALE 1/4 INCH = 1 FOOT

BUILDING SECTION

SCALE 3/4 INCH = 1 FOOT

WALL SECTION

SCALE: 1/4" = 1'-0"

2' 4'0 8'

V A

R I E

S

R E

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

8" CMU

CONCRETE FLOOR ON

VAPOR BARRIER

5/8" GWB OVER 2 1/2"

METAL STUDS @

16" OC WITH 2 1/2"

BATT INSUL (R-8)

STANDING SEAM

METAL ROOFING

RIGID ROOF

INSULATION (R-38)

METAL DECKING

3" CAVITY WALL

INSULATION (R-18)

METAL FASCIA PANELS ON

5/8" GLASS-MAT GYPSUM

SHEATHING BOARD

METAL DOWNSPOUT BEYOND

MET GUTTER

FOUNDATIONS -

SEE STRUCT

CONCRETE

SPLASH BLOCK

VENTED METAL SOFFIT PANELS

ON 3 5/8" GALV METAL FRAMING

EAVE HEIGHT

ELEV. =112'-6"

BOT OF SOFFIT

ELEV. =110'-1 1/2"

TOP OF CMU

ELEV. =112'-6"

FINISH FLOOR

ELEV. =100'-0"

PORTLAND CEMENT STUCCO

SYSTEM OVER GYPSUM

SHEATHING

4" ROCKFACE CMU

STEEL JOIST - SEE

STRUCT

SUSPENDED

ACOUSTIC TILE

CEILING

PRE-CAST SILL - SEE

DETAIL 4/AE602A

SOLID SURFACE

SILL & APRON

ALUM WINDOW

SEALANT

FLUID-APPLIED AIR

BARRIER

THRU-WALL FLASHING

w/ WEEPS @ 24" OC

10" HIGH DRAINAGE

WALL SYSTEM

1/2" COMPRESSIBLE

FILLER & SEALANT

2" PERIMETER

INSULATION

SPRAY-ON FOAM

THERMAL INSULATION

TO FILL ALL VOIDS IN

WALLS & ROOF

T.O. PARAPET (BEYOND)

FACE OF STUCCO WALL

(BEYOND)

FACE OF CMU WALL (BEYOND)

8"

AE603A

AE603A

GWB & METAL

STUDS EXTEND TO

TOP OF CMU

TOP OF CMU

ELEV. VARIES

FINISH FLOOR

ELEV. 100'-0"

8" CMU

CONCRETE FLOOR ON

VAPOR BARRIER

3" CAVITY WALL

INSULATION (R-18)

PORTLAND CEMENT

STUCCO SYSTEM OVER

GYPSUM SHEATHING

4" ROCKFACE CMU

SUSPENDED

ACOUSTIC TILE

CEILING

METAL DECKING

STANDING SEAM

METAL ROOFING

PREFINISHED METAL

COPING

RIGID ROOF

INSULATION (R-38)

PRE-CAST SILL - SEE

DETAIL 4/AE602A

SOLID SURFACE

SILL & APRON

FOUNDATIONS -

SEE STRUCT

ALUM WINDOW

5/8" GWB OVER 2 1/2"

METAL STUDS @

16" OC WITH 2 1/2"

BATT INSUL (R-8)

FLUID-APPLIED AIR

BARRIER

THRU-WALL FLASHING

w/ WEEPS @ 24" OC

10" HIGH DRAINAGE

WALL SYSTEM

1/2" COMPRESSIBLE

FILLER & SEALANT

2" PERIMETER

INSULATION

8"

AE603A

AE603A

GWB & METAL STUDS

EXTEND TO TOP OF

CMU

TOP OF CMU

ELEV. VARIES

FINISH FLOOR

ELEV. 100'-0"

8" CMU

CONCRETE FLOOR ON

VAPOR BARRIER

3" CAVITY WALL

INSULATION (R-18)

PORTLAND CEMENT

STUCCO SYSTEM OVER

GYPSUM SHEATHING

4" ROCKFACE CMU

SUSPENDED

ACOUSTIC TILE

CEILING

METAL DECKING

STANDING SEAM

METAL ROOFING

PREFINISHED METAL

COPING

RIGID ROOF

INSULATION (R-38)

PRE-CAST SILL - SEE

DETAIL 5/AE602A

FOUNDATIONS -

SEE STRUCT

FLUID-APPLIED AIR

BARRIER

THRU-WALL FLASHING w/

WEEPS @ 24" OC

10" HIGH DRAINAGE

WALL SYSTEM

1/2" COMPRESSIBLE

FILLER & SEALANT

2" PERIMETER

INSULATION

TOP OF ROCK FACE CMU

ELEV. 103'-2"

8"

SCALE: 3/4" = 1'-0"

8" 1'-4"0 2'-8"

SCALE 3/4 INCH = 1 FOOT

WALL SECTION

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

X

P R

O J E

D

E S

C

SCALE 3/4 INCH = 1 FOOT

WALL SECTION

AE302A

R

A

E

A D

W G

W A

C

T I O

N S

K F

B

R E

D E

H O

E

P P

R

B U

I L D

I N

G

A

T

SCALE 3/4 INCH = 1 FOOT

WALL SECTION

R E

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

UNDERSIDE OF DECK

NON COMBUSTIBLE

COMPRESSIBLE FILLER

FINISH CEILING WHERE

OCCURS (SEE SCHEDULE)

3-5/8" MTL STUD

FRAMING @ 16" OC

X 25 GA TO 15'-4" AFF

MAX., AND 20 GA IF

EXTENDING ABOVE

15'-4" AFF

5/8" GWB EACH SIDE

WALL BASE (SEE

SCHEDULE)

FINISH FLOOR (SEE

SCHEDULE)

UNDERSIDE OF DECK

NON COMBUSTIBLE

COMPRESSIBLE FILLER

FINISH CEILING WHERE

OCCURS (SEE SCHEDULE)

CERAMIC TILE

WAINSCOT

WALL BASE (SEE

SCHEDULE)

FINISH FLOOR (SEE

SCHEDULE)

5/8" GWB EACH SIDE

SOUND BLANKET

INSULATION

WALL TYPE NOTES:

1. TOP OF CERAMIC TILE WAINSCOT

SHALL BE A BULLNOSE TILE WITH

JOINT BETWEEN CERAMIC TILE AND

GWB SEALED AND CAULK.

2. WHERE METAL STUD PARTITIONS

EXTEND TO STRUCTURE ABOVE,

PROVIDE DOUBLE HEAD TRACK TO

ALLOW SLIPPAGE TO COMPENSATE

FOR DEFLECTION OF THE ROOF

STRUCTURE ABOVE. REFER TO

DETAILS 7 & 8/AE603A.

3. ALL WALLS INDICATED AS FIRE

RATED SHALL RECEIVE 5/8" TYPE "X"

GYPSUM WALLBOARD ON BOTH

FACES, FULL HEIGHT.

4. ALL 1-HOUR FIRE RATED GWB WALLS

SHALL BE CONSTRUCTED TO MEET

UL DESIGN NO. U465 CRITERIA.

5. WHERE CERAMIC TILE OCCURS,

INSTALL A 5/8" MOISTURE RESISTANT

GYPSUM BOARD SUBSTRATE.

5/8" TYPE X GWB

@ RATED WALLS

5/8" TYPE X GWB

@ RATED WALLS

UNDERSIDE OF DECK

NON COMBUSTIBLE

COMPRESSIBLE FILLER

FINISH CEILING WHERE

OCCURS (SEE SCHEDULE)

5/8" GWB EACH SIDE

5/8" TYPE X GWB

@ RATED WALLS

3-5/8" MTL STUD

FRAMING @ 16" OC

X 25 GA TO 15'-4" AFF

MAX., AND 20 GA IF

EXTENDING ABOVE

15'-4" AFF

CERAMIC TILE

WAINSCOT - BOTH

SIDES OF WALL

WALL BASE (SEE

SCHEDULE)

FINISH FLOOR (SEE

SCHEDULE)

3-5/8" MTL STUD

FRAMING @ 16" OC

X 25 GA TO 15'-4" AFF

MAX., AND 20 GA IF

EXTENDING ABOVE

15'-4" AFF

SOUND BLANKET

INSULATION

SOUND BLANKET

INSULATION

UNDERSIDE OF DECK

NON COMBUSTIBLE

COMPRESSIBLE FILLER

FINISH CEILING WHERE

OCCURS (SEE SCHEDULE)

4" MTL STUD FRAMING

@ 16" OC X 25 GA TO

15'-4" AFF MAX., AND

20 GA IF EXTENDING

ABOVE 15'-4" AFF

5/8" GWB EACH SIDE

WALL BASE (SEE

SCHEDULE)

FINISH FLOOR (SEE

SCHEDULE)

SOUND BLANKET

INSULATION

5/8" TYPE X GWB

@ RATED WALLS

SCALE: 3/4" = 1'-0"

8" 1'-4"0 2'-8"

3" NUMBER

1/8" RULE

2" LETTERS

1'-6"

NOTE:

BUILDING ENTRANCE SIGNS

PLACEMENT OF GRAPHIC

REFER TO UFC 3-120-01

FIGURE 3-14. MOUNTING

DIMENSIONS AS SHOWN.

VERIFY BUILDING NAME,

NUMBER, AND LOCATION WITH

CONTRACTING OFFICER. SEE

SPECIFICATIONS.

XXXX

Petroleum

Operation

PORTLAND CEMENT

STUCCO FINISH

#10x3/4" COUNTERSINK SOCKET

HEAD THREAD CUTTING SCREW

.06" ALUMINUM SHEETING

RETURN SHEETING ALL

AROUND WELD CORNERS

AND GRID SMOOTH

ALTERNATE: (1"x1"x1/8")

ANGLE FRAME BONDED TO

ALUMINUM SIGN PANEL

3/4"x1"x1/8" ALUMINUM

ANGLE

NOTES:

1. PANEL TO BE FINISHED WITH BAKED

ENAMEL ALL AROUND. REFLECTIVE

SHEETING MY BE APPLIED IF NIGHT

TIME VISIBILITY IS REQUIRED.

2. SIGNAGE COMPANY SHALL

DETERMINE PROPER FASTENING

SYSTEM FOR SECURING SIGNAGE TO

A MODERN STUCCO SYSTEM WITH A

GYPSUM SHEATHING SUBSTRATE.

MECHANICAL ROOM

1'-0"

1/2"

.06" ALUMINUM SHEETING

RETURN SHEETING ALL

AROUND WELD CORNERS AND

GRID SMOOTH

ALTERNATE: (1"x1"x1/8") ANGLE

FRAME BONDED TO ALUMINUM

SIGN PANEL

3" HELVETICA MEDIUM

ACRYLIC LETTERS

GRADE TWO BRAILLE

1/2" HELVETICA MEDIUM

ACRYLIC LETTERS WITH 3/8"

SPACE BETWEEN LINES

NOTE: EXTERIOR ROOM SIGN AT

COMMUNICATIONS ROOM 105 AND

MECHANICAL ROOM 106. VERIFY ROOM

NAMES, NUMBERS AND LOCATION WITH

CONTRACTING OFFICER. CONSTRUCTION

SAME AS 1/AE303A SIGNS

9"

1/2"

LAMINATED CAST ACRYLIC,

CLEAR FACE WITH COLORED

BACK.

1-1/2" HELVETICA MEDIUM

ACRYLIC LETTERS

GRADE TWO BRAILLE

INTERCHANGEABLE MESSAGE

STRIP WITH 1/2" HELVETICA

MEDIUM ACRYLIC LETTERS

WITH 3/8" SPACE BETWEEN

LINES

SCALE: 3" = 1'-0"

2" 4"0 8"

SCALE: 1 1/2" = 1'-0"

4" 8"0 1'-4"

9"

WHERE SIGN IS INDICATED

ADJACENT TO A WALL

CORNER, RATHER THAN A

DOOR: MOUNT CENTER OF

SIGN 9" FROM THE CORNER

NOTE: REFER TO SPEC AND

PLANS FOR INTENDED

LOCATION FOR EACH SIGN.

MTL STUD PARTITION

1-1/2 INCH = 1 FOOT

SCALE:

MTL STUD PARTITION

1-1/2 INCH = 1 FOOT

SCALE:

MTL STUD PARTITION

1-1/2 INCH = 1 FOOT

SCALE:

NOTE: 1 HOUR RATED WALLS AT MECH 106 - SEE

SHEET AE102A FOR LOCATIONS - PER UL DESIGN NO. U465

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

X

P R

O J E

D

E S

C

AE303A

R E

W

C N

A

E

A D

W G

P A

R T

I T

I O

N

T

Y P

T

A I L S

K F

B

R E

D E

H O

E

P P

R

B U

I L D

I N

G

A

T

SCALE 3/4 INCH = 1 FOOT

EXTERIOR BUILDING SIGNS DETAIL

SCALE 1 1/2 INCH = 1 FOOT

EXTERIOR SIGNS DETAIL

SCALE 3 INCH = 1 FOOT

EXTERIOR ROOM SIGNS DETAIL

SCALE 3 INCH = 1 FOOT

INTERIOR ROOM SIGNS DETAIL

NOTE: 1 HOUR RATED WALLS AT MECH 106 - SEE

SHEET AE102A FOR LOCATIONS - PER UL DESIGN NO. U465

MTL STUD PARTITION

1-1/2 INCH = 1 FOOT

SCALE:

V A

R I E

S

SCALE 1 1/2 INCH = 1 FOOT

PREFERRED INTERIOR SIGN PLACEMENTS

R E

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

SD 1

MG

PRT-2 4"x12" W/

BULLNOSE TOP

SCRIBE

2"

2'-9"

PRT-2 COVE

BASE

GT-1

CERAMIC TILE

WAINSCOT

PRT-2 TYPE

FIELD TILE

GWB P-4

PL-1 PLAM BASE

PL-1

FINISHED

END PANEL

4'-5 1/2"

2"

AE305A

SOLID

SURFACE

COUNTERTOP

SS-1

PTDWR

4'-9 1/2"

PRT-2 4"x12" W/

BULLNOSE TOP

PRT-2 COVE BASE

GT-1

CERAMIC TILE

WAINSCOT

PRT-2 TYPE

FIELD TILE

GWB P-4

11'-7"

GWB P-4

CERAMIC TILE

WAINSCOT

PRT-2 TYPE

FIELD TILE

GT-1

PRT-2 COVE

BASE

PRT-2 4"x12" W/

BULLNOSE TOP

PL-1 CABINET FINISHED

END PANEL

PRT-2

COVE BASE

METAL LOCKERS

(ML-1)

36"x36" SHOWER

UNIT - SEE

MECHANICAL

ACRYLIC BASE

(BY SHOWER

UNIT MANUF)

PTDWR @

ADJACENT

WALL

3'-9"2'-1"

4 3/4" 3/4"

FILLER

3'-0"3'-4"

NOTE: NO TILE

REQUIRED BEHIND

LOCKERS.

TP

TTD

1'-7 1/2"

GWB P-4

CERAMIC TILE

WAINSCOT

PRT-2 TYPE

FIELD TILE

GT-1

PRT-2 COVE

BASE

PRT-2 4"x12" W/

BULLNOSE TOP

ACRYLIC BASE

(BY SHOWER

UNIT MANUF)

36"x36" SHOWER

UNIT - SEE

MECHANICAL

SND

LOCKER UNITS AT

ADJACENT WALL

7'-1 1/2"

CERAMIC

TILE

WAINSCOT

PRT-2 TYP

FIELD TILE

PRT-2 COVE

BASE

PRT-2 4"x12" W /

BULLNOSE TOP

GLASS TILE

GT-1

GWB

P-4

SD 1

MG

PRT-2 4"x12" W/

BULLNOSE TOP

SCRIBE

2"

2'-9"

PRT-2 COVE

BASE

GT-1

CERAMIC TILE

WAINSCOT

PRT-2 TYPE

FIELD TILE

GWB P-4

PL-1 PLAM BASE

PL-1

FINISHED

END PANEL

4'-5 1/2"

2"

AE305A

SOLID

SURFACE

COUNTERTOP

SS-1

MEN

WOMEN

3 LOCKERS (ML) -

SEE 5/AE305A

EWC

SHOWER UNIT W/

SWING DOOR - SEE

SPECIFICATIONS

3 LOCKERS (ML) -

SEE 5/AE305A

SHOWER UNIT W/

SWING DOOR - SEE

SPECIFICATIONS

FD

MG

SD 1

TP

TTD

SND

TTD

PTDWR

TP

FD

MG

SD 1

11'-8 1/4"

7'-2 3/4"

7'-2 3/4"

3'-1"

3'-1"

4'-9 1/2"

4'-9 1/2"

PTDWR

VENDING

MACHINE

REFRIGERATOR

B

CT

AE305A

AE304A

AE304A

AE304A

AE304A

AE305A

AE304A

AE305A

AE305A

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

X

P R

O J E

D

E S

C

AE304A

R E

W

C N

A

E

A D

W G

E N

L A

R G

O

A

N

I N

T E

R I O

R

E

L E

V A

T I O

N S

K F

B

R E

D E

H O

E

P P

R

B U

I L D

I N

G

A

T

SCALE 1/2 INCH = 1 FOOT

ENLARGED FLOOR PLAN

SCALE 1/2 INCH = 1 FOOT

WOMEN 103

SCALE 1/2 INCH = 1 FOOT

WOMEN 103

SCALE 1/2 INCH = 1 FOOT

WOMEN 103

SCALE 1/2 INCH = 1 FOOT

WOMEN 103

SCALE: 1/2" = 1'-0"

1' 2'0 4'

SCALE 1/2 INCH = 1 FOOT

TYP TILE PATTERN ELEVATION

SCALE 1/2 INCH = 1 FOOT

MEN 104

SHEET NOTE:

DIMENSIONS TO PARTITION

WALLS ON INTERIOR

ELEVATION DRAWINGS ARE

TYPICALLY TO INSIDE FACE

OF GWB.

R E

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

PTDWR

4'-9 1/2"

PRT-2 4"x12" W/

BULLNOSE TOP

PRT-2 COVE BASE

GT-1

CERAMIC TILE

WAINSCOT

PRT-2 TYPE

FIELD TILE

GWB P-4

11'-7"

TP

TTD

1'-7 1/2"

GWB P-4

CERAMIC TILE

WAINSCOT

PRT-2 TYPE

FIELD TILE

GT-1

PRT-2 COVE

BASE

PRT-2 4"x12" W/

BULLNOSE TOP

ACRYLIC BASE

(BY SHOWER

UNIT MANUF)

36"x36" SHOWER

UNIT - SEE

MECHANICAL

LOCKER UNITS AT

ADJACENT WALL

7'-1 1/2"

SND

GWB P-4

CERAMIC TILE

WAINSCOT

PRT-2 TYPE

FIELD TILE

GT-1

PRT-2 COVE

BASE

PRT-2 4"x12" W/

BULLNOSE TOP

PL-1 CABINET

FINISHED END

PANEL

PRT-2 COVE

BASE

METAL LOCKERS

(ML-1)

36"x36" SHOWER

UNIT - SEE

MECHANICAL

ACRYLIC BASE

(BY SHOWER

UNIT MANUF)

PTDWR @

ADJACENT

WALL

3'-4"3'-0"

3/4"

FILLER

6'-3"

NOTE: NO TILE

REQUIRED BEHIND

LOCKERS.

BULLNOSE

EDGES -TYP

CERAMIC

TILE

WAINSCOT

PRT-2 TYP

FIELD TILE

PRT-2 COVE

BASE

PRT-2

4"x12" W /

BULLNOSE

TOP

O

U T

3'-0"

TILE SIDE

WALL -

RETURNS 12"

GWB P-3

1'-6"

TOWEL

(TP)

WALL LINE

(TTD)

TOILET TISSUE

DISPENSER

(SND)

SANITARY NAPKIN

DISPOSER

(SD 1)

SOAP

DISPENSER

(MG)

MIRROR

(ML)

METAL LOCKER

PRT-2 COVE

BASE

SLOPED TOP

PIN

2'-0"

1'-0"

(PTDWR)

M A

X

PAPER TOWEL DISPENSER

WASTE RECEPTACLE

GWB P-3

BASE: 3/4" HIGH DENSITY

PART BD CLAD W/ PL-1

PLAS LAM

3"

INSIDE OF

CABINET CLAD

ALL SURFACES W/

MELAMINE OR

PLAS LAM (TYP)

3/4" HIGH DENSITY PART BD

W/ ALL EXPOSED SURFACES

(ENDS, EDGES & FACES OF

PANELS) CLAD W/ PL-1

3/4" THICK SOLID SURFACE

MATERIAL COUNTERTOP

(SS-1) OVER 3/4" PLYWD

SUBSTRATE

2'-0 3/4"

PLASTIC

LAMINATE CLAD

CASEWORK SEE

SPECIFICATIONS

2'-0"

RADIUS EDGE

SOLID SURFACE

BACKSPLASH (SS-1)

INTEGRAL SINK - SEE MECH

SEALANT

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

X

P R

O J E

D

E S

C

AE305A

R E

W

C N

A

E

A D

W G

I N

T E

R I O

R

E

L E

V A

T I O

T

A I L

S

K F

B

R E

D E

H O

E

P P

R

B U

I L D

I N

G

A

T

SCALE: 1/2" = 1'-0"

1' 2'0 4'

SCALE 1/2 INCH = 1 FOOT

MEN 104

SCALE 1/2 INCH = 1 FOOT

MEN 104

SCALE 1/2 INCH = 1 FOOT

MEN 104

SCALE 1/2 INCH = 1 FOOT

EWC ELEVATION

SCALE 1/2 INCH = 1 FOOT

TOILET ACCESSORIES

SCALE 1 1/2 INCH = 1 FOOT

MILLWORK SECTION

SCALE: 1 1/2" = 1'-0"

4" 8"0 1'-4"

V A

R I E

S

SHEET NOTE:

DIMENSIONS TO PARTITION

WALLS ON INTERIOR

ELEVATIONS ARE TO INSIDE

FACE OF GWB.

R E

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

OPEN OFFICE

AREA

MECH

COMM

CUST

MEN

WOMEN

RCC

OFFICE

NOTE: NO FLOOR

TILE REQUIRED

BELOW VANITY

CABINET,

LOCKERS, OR

SHOWER BASIN.

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

X

P R

O J E

D

E S

C

TRUE

NORTH

SCALE: 1/4" = 1'-0"

2' 4'0 8'

SCALE 1/4 INCH = 1 FOOT

FLOOR FINISH PLAN

PLAN

AE601A

R

A

E

A D

W G

R O

N

I S

H

S

C H

E D

U L

O

O R

F I N

I S

H

P

L A

N

K F

B

R E

D E

H O

E

P P

R

A F

B U

I L D

I N

G

A

T

ROOM FINISH SCHEDULE

ROOM NAME

FLOOR

WOMEN

RCC

OFFICE

BASE

EAST WEST

WALLS

SOUTH NORTH MAT. HT.

CEILINGS

NO.

ROOM

REMARKS

(SEE NOTES

BELOW)

104 MEN

ROOM FINISH SCHEDULE LEGEND

FLOOR TYPES

F1 CONCRETE

BASE TYPES

B1 RESILIENT

WALL FINISHES

W1 PAINTED GYPSUM

1. SEALED CAST - IN - PLACE

CONCRETE FLOOR. LIQUID CHEMICAL

SEALER - HARDENER COMPOUND.

WALL BOARD

COMM

F2 PORCELAIN TILE

CEILING TYPES

C2 SUSPENDED ACOUSTICAL TILE

2. SLOPED GYPSUM WALLBOARD CEILING:

5/8" GYPSUM WALLBOARD OVER 1 1/2"

GALVANIZED HAT CHANNELS @ 24" OC

ATTACHED TO THE UNDERSIDE OF STEEL

JOISTS (ORIENTED PERPENDICULAR TO

JOISTS).

REMARKS:

C1 PAINTED GYPSUM WALLBOARD

9'-0"

9'-0"

OPEN OFFICE AREA

W1 (P-3) C2 (ACT-1) 9'-0"B2 (PRT)

F2 (PRT-1)

9'-0"

F2 (PRT-1,3,4), F3 (WM-1)

C1 (P-6)

F1

3,4

3,4

1,5

MECH

F1

F2 (PRT-1)

W2 (P-3)

9'-0"

1,2

F2 (PRT-1,4)

F2 (PRT-1,4)

W2 CMU PAINTED

VARIES

9'-0"

W3 PORCELAIN TILE (PRT-2)

W1(P-4)/W3

CUST

F1 1 9'-0"

F3 WALK-OFF MAT CARPET TILE

B1 (VB-1)

B1 (VB-1)

B1 (VB-1)

W1(P-3)/W3 W1 (P-3) W1 (P-3)

W1 (P-3) W1 (P-3) W1 (P-3) W1 (P-3)

W1 (P-3) W1 (P-3) W1 (P-3) W1 (P-3)

W1(P-4)/W3 W1(P-4)/W3 W1(P-4)/W3

W1(P-4)/W3 W1(P-4)/W3 W1(P-4)/W3 W1(P-4)/W3

W1 (P-3) W1 (P-3) W1 (P-3) W1 (P-3)

W1 (P-3) W2 (P-3) W1 (P-3)

W1 (P-3) W1 (P-3) W1 (P-3) W1 (P-3)

C2 (ACT-1)

C2 (ACT-1)

C2 (ACT-1)

C1 (P-6)

C1 (P-6)

C1 (P-6)

3. SEE PORCELAIN TILE PATTERN LEGEND

BELOW & FLOOR FINISH PLAN 1/AE601A.

LEGEND:

PRT-3

PRT-4

PRT-1

PRT-1 (FIELD TILE)

PRT-3

PRT-4

4. 7'-0" HIGH CERAMIC TILE WAINSCOT:

PORCELAIN TILE PRT-2 & GLASS TILE GT-1.

GROUT TO BE G-2. SEE PATTERN SHOWN

ON DETAIL 2/AE304A.

WM-1

NOTE: AT ALL FLOOR TILE AREAS, INSTALL GROUT G-1.

B2 (PRT)

B2 (PRT)

B2 (PRT)

B2 (PRT)

B2 PORCELAIN TILE

5. PROVIDE CORNER GUARDS (CG)

WHERE NOTED ON THE FLOOR PLAN ON

SHEET AE101A, AND PER REQUIREMENTS

OF SPEC SECTION 102613.

R E

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

FG

3'-0" 3'-0"

GLASS TYPE

NO. 1

5" 5"

A

GLASS TYPE

NO. 1

2" 2"

EQ

ALUM FRAME

4'-0"

2"

EQ

B

GLASS TYPE NO. 3

(SLIDING PANELS)

ALUM FRAME AT

3 SIDES OF OPENING

ALUM TRACK

AROUND FULL

PERIMETER

CYLINDER

LOCK @

OFFICE SIDE

3'-0"

2"

2"

1" DIA THUMB HOLE

W/ EDGES GROUND

SMOOTH, TYP BOTH

PANELS

SOLID SURFACE

COUNTER WITH

APRON

AE603A

AE603A

AE603A

AE602A

AE602A

AE602A

ALUMINUM

WINDOW

ALUMINUM

WINDOW

A

S E

E

S

C H

E D

U L

E

SEE

SCHED

2" 2"

2" 8"

1/4"

3/8"

10"

AL FRAME

GLASS TYPE NO. 3

(SLIDER PANEL)

5/8" GWB OVER 3-5/8"

METAL STUDS @ 16" OC

WITH BATT INSULATION

4 1/2"

AL TRACK

SEALANT BOTH SIDES

SHIM

GLASS TYPE NO. 3

(SLIDER PANEL)

5/8" GWB

FULLY RECESSED AL TRACK

RADIUS EDGE

SOLID SURFACE

MATERIAL APRON

6" 6"

3/4" PLYWD SUBSTRATE

2x4 WOOD FRAMING

4" 1"

1/4"

3/8"

5"

3" CAVITY WALL

INSULATION (R-18)

SHIM AS REQUIRED

W/ BACKER ROD

AND SEALANT

SEALANT

WALL REINFORCING -

SEE STRUCT

AIR-BARRIER COATING

8" CMU

HM FRAME

HM DOOR - SEE

SCHEDULE

7"5 3/4"5 1/2"

5 1/2" 5 3/4" 6 3/4"

5/8" GWB RETURN

5/8" GWB OVER 2 1/2"

METAL STUDS @ 16" OC

WITH 2 1/2" BATT

INSULATION (R-8)

3" CAVITY WALL

INSULATION (R-18)

SHIM AS REQUIRED

W/ BACKER ROD

AND SEALANT

SEALANT

HEADER

REINFORCING -

SEE STRUCT

AIR-BARRIER

COATING

8" CMU

HM FRAME

HM DOOR - SEE

SCHEDULE

5/8" GWB RETURN

STUCCO RETURN

PORTLAND CEMENT

STUCCO SYSTEM OVER

GYPSUM SHEATHING

4" ROCKFACE

CMU

3" CAVITY WALL

INSULATION

(R-18)

SHIM AS REQUIRED

W/ BACKER ROD

AND SEALANT

SEALANT

WALL

REINFORCING -

SEE STRUCT

AIR-BARRIER

COATING

8" CMU

HM FRAME

HM DOOR - SEE

SCHEDULE

7"5 3/4"

BLOCK

RETURN TYP

AT ALL JAMBS

5 1/2"

5/8" GWB RETURN

PORTLAND CEMENT

STUCCO SYSTEM OVER

GYPSUM SHEATHING

STUCCO RETURN

VERIFY

5/8" GWB OVER 2 1/2"

METAL STUDS @ 16" OC

WITH 2 1/2" BATT

INSULATION (R-8)

5/8" GWB OVER 2 1/2"

METAL STUDS @ 16" OC

WITH 2 1/2" BATT

INSULATION (R-8)

HM FRAME

5/8" GWB OVER METAL

STUDS @ 16" OC WITH

BATT INSULATION - STUD

DEPTH PER WALL TYPE

DOOR - SEE

SCHEDULE

1/2" TYP

PER WALL

TYPE

DOOR SCHEDULE

DETAILS

FRAME

DOOR

HDWR

SET

DOOR SIZE

SILLHEAD JAMB

TYPE

TYPE

MAT.

F HM A

MAT.

DOOR

NO.

FIRE LABEL &

RATING

REMARKS

(SEE NOTES

BELOW)

101 3'-0" x 7'-0" x 1 3/4" HM A HM

3'-0" x 7'-0" x 1 3/4"

PR 2'-10" x 7'-0" x 1 3/4"

3'-0" x 7'-0" x 1 3/4"

F

F

F

F

A

A

HM

HM

HM

A

GLASS TYPES:

NO.1: 1" INSULATED BRONZE TINTED LOW-E BLAST RESISTANT GLAZING

NO.3: 1/4" CLEAR, TEMPERED GLAZING (INTERIOR WINDOW GLAZING)

HM

HM

HM

HM

100 3'-0" x 7'-0" x 1 3/4" A HMFG 1,4

SCALE: 1/2" = 1'-0"

1' 2'0 4'

DOOR TYPES

1/2 INCH = 1 FOOTSCALE

DOOR FRAME TYPES

1/2 INCH = 1 FOOT

SCALE

WINDOW FRAME TYPES

1/2 INCH = 1 FOOTSCALE

DOOR REMARKS:

1. INSULATED DOOR

2. 1" UNDERCUT

3. NO GWB OR METAL STUDS REQUIRED AT

INTERIOR SIDE OF 8" CMU AT THIS DOOR.

4. EXTRA HEAVY DUTY DOOR

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

X

P R

O J E

D

E S

C

HM

F HM A

3'-0" x 7'-0" x 1 3/4"

106 HM

1,2,4

1,3,4

107 3'-0" x 7'-0" x 1 3/4"

F HM A HM

AE602A

R

A

E

A D

W G

D O

H

E D

U

T

A I L S

K F

B

R E

D E

H O

E

P P

R

A F

B U

I L D

I N

G

A

T

60 MIN

V A

R I E

S

SCALE 3 INCH = 1 FOOT

HEAD/JAMB DETAIL

SCALE 3 INCH = 1 FOOT

HEAD/JAMB DETAIL

SCALE 3 INCH = 1 FOOT

SILL DETAIL

SCALE 3 INCH = 1 FOOT

PRECAST SILL DETAIL

SCALE 3 INCH = 1 FOOT

PRECAST SILL DETAIL

SCALE 3 INCH = 1 FOOT

HEAD DETAIL

SCALE 3 INCH = 1 FOOT

JAMB DETAIL

SCALE: 3" = 1'-0"

2" 4"0 8"

SCALE 3 INCH = 1 FOOT

JAMB DETAIL

1/AE603A6/AE602A 7 & 8/AE602A

1/AE602A 1/AE602A

1/AE602A 1/AE602A

3'-0" x 7'-0" x 1 3/4"

1/AE602A 1/AE602A

1/AE602A 1/AE602A

1/AE603A6/AE602A 7 & 8/AE602A

1/AE603A6/AE602A (SIM) 7 & 8/AE602A (SIM)

1/AE602A 1/AE602A

HW-1

HW-3

HW-3

HW-5

HW-5

HW-7

HW-1

HW-6

1,4

1,4

1,2,4

1,4

1,4

R E

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

HM DOOR -SEE

SCHEDULE

STRUCTURAL

STOOP - SEE

STRUCT

THRESHOLD SET

IN SEALANT

CONC FLOOR ON

VAPOR BARRIER

COMPRESSIBLE

FILLER

CONC

FOUNDATION -

SEE STRUCT

6 1/2"

5/8" GWB OVER 2 1/2"

METAL STUDS @ 16" OC

WITH 2 1/2" BATT

INSULATION (R-8)

3" CAVITY WALL

INSULATION (R-18)

SHIM AS REQUIRED

W/ BACKER ROD

AND SEALANT

SEALANT

HEADER

REINFORCING -

SEE STRUCT

AIR-BARRIER

COATING

8" CMU

ALUM FRAME

5/8" GWB RETURN

STUCCO RETURN

PORTLAND CEMENT

STUCCO SYSTEM OVER

GYPSUM SHEATHING

1"

5/8" GWB OVER 2 1/2"

METAL STUDS @ 16" OC

WITH 2 1/2" BATT

INSULATION (R-8)

3" CAVITY WALL

INSULATION (R-18)

SHIM AS REQUIRED

W/ BACKER ROD

AND SEALANT

SEALANT

WALL REINFORCING -

SEE STRUCT

AIR-BARRIER COATING

8" CMU

ALUM FRAME

6 1/2"

5/8" GWB RETURN

PORTLAND CEMENT

STUCCO SYSTEM OVER

GYPSUM SHEATHING

STUCCO RETURN

1 1/2"

6 1/2"

5/8" GWB OVER

2 1/2" METAL

STUDS @ 16" OC

WITH 2 1/2" BATT

INSULATION (R-8)

8" CMU BOND BEAM -

SEE STRUCT

SOLID SURFACE SILL

AND APRON

ALUM FRAME

THRU WALL

FLASHING

4" ROCK FACE

CMU

AIR-BARRIER

COATING PER

SPECIFICATIONS

PRECAST SILL

WITH DRIP SEE

DETAIL 4/AE602A

1/4" SHIM WITH

BACKER ROD &

SEALANT (BOTH

SIDES)

3" CAVITY WALL

INSULATION (R-18)

SEALANT

SEMI-RECESSED

STEEL CABINET

CABINET

DOOR PULL

GLASS VISION

PANEL

SPRING LOCK

T.O. CABINET

EL. = 5'-0"

5/8" GWB ON 2-1/2"

METAL STUDS

4" MAX

8"

MAX

1'-8" MAX

M

A X

SEE WALL

TYPES

NOTE:

SEE SPECIFICATIONS

FOR FURTHER

INFORMATION.

PIANO HINGE

CABINET DOOR

8" CMU

PROVIDE

BLOCK-OUT

IN CMU TO

ALLOW

INSTALLATION

OF CABINET

SEALANT

15# FELT (HOLD

TO ONE SIDE)

CMU

GROUT FILL

3" CAVITY WALL

INSUL.

4" CMU VENEER

COMPRESSIBLE

FILLER

SEALANT

WOOD BLOCKING

E-Z STRIP CONTROL JOINT

5/8" GWB OVER

2 1/2" METAL

STUDS @ 16" OC

WITH 2 1/2" BATT

INSULATION (R-8)

WALL

REINFORCING -

SEE STRUCT

SAFING (FOAM INSULATION @

FIRE RATED PARTITIONS)

METAL DECK

GYP SETTING SEALANT

DRYWALL SCREW

@ 6" OC

METAL FASTENER

5/8" GWB

DRYWALL SCREW

5/8" GYP BD-TYPE

X @ FIRE RATED

PARTITIONS

METAL STUD

MECH/ELEC

PENETRATION

FIRE STOPPING

SEALANT BOTH

SIDES OF WALL

NOTE:

FIRE STOPPING MATERIALS

SHALL PROVIDE FIRE

RESISTANCE RATING EQUAL

TO RATING OF PARTITION.

NOTE:

THIS DETAIL IS BASED ON

THE FIRE TRACK CORP.

DEFLECTION TRACK

SYSTEM. SEE MFG

CATALOG FOR U.L. TESTED

SYSTEMS.

SAFING (FOAM INSULATION @

FIRE RATED PARTITIONS)

TOP OF METAL DECK

BOTTOM OF METAL DECK

GYP SETTING SEALANT

DRYWALL SCREW @ 6" OC

METAL FASTENER

5/8" GWB

DRYWALL SCREW

5/8" GYP BD-TYPE

X @ FIRE RATED

PARTITIONS

METAL STUD

MECH/ELEC

PENETRATION

FIRE STOPPING

SEALANT BOTH

SIDES OF WALL

NOTE:

FIRE STOPPING MATERIALS

SHALL PROVIDE FIRE

RESISTANCE RATING

EQUAL TO RATING OF

PARTITION.

NOTE:

THIS DETAIL IS BASED ON

THE FIRE TRACK CORP.

DEFLECTION TRACK

SYSTEM SEE MFG CATALOG

FOR U.L. TESTED SYSTEMS.

1"

4"

REINFORCING AS

SPECIFIED

SECTION A

PLAN

NOTE:

PRECAST SPLASH BLOCKS SHALL BE

CONSTRUCTED OF 4000 PSI CONC

(CONFORMING TO SECTION) FOR

BUILDING CONSTRUCTION USING 1/2"

TO NO.4 NOMINAL SIZE COARSE

AGGREGATE. REINFORCING SHALL BE

PER MANUFACTURER'S STANDARDS.

FINISH GRADE

2'-0"

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

X

P R

O J E

D

E S

C

AE603A

R

A

E

A D

W G

D E

T A

I L

S

K F

B

R E

D E

H O

E

P P

R

A F

B U

I L D

I N

G

A

T

V

R I E

S

SCALE 3 INCH = 1 FOOT

SILL DETAIL

SCALE: 3" = 1'-0"

2" 4"0 8"

SCALE 3 INCH = 1 FOOT

HEAD DETAIL

SCALE 3 INCH = 1 FOOT

JAMB DETAIL

SCALE 3 INCH = 1 FOOT

SILL DETAIL

SCALE: 1 1/2" = 1'-0"

4" 8"0 1'-4"

SCALE 1 1/2 INCH = 1 FOOT

FIRE EXTINGUISHER CABINET ELEVATION/DETAIL (FEC) TYP

SCALE 1 1/2 INCH = 1 FOOT

MASONRY CONTROL JOINT (MCJ) TYP

SCALE 3 INCH = 1 FOOT

DEFLECTION TRACK PARALLEL TO DECK

SCALE 3 INCH = 1 FOOT

DEFLECTION TRACK PERPENDICULAR TO DECK

SCALE 1 1/2 INCH = 1 FOOT

CONCRETE SPLASHBLOCK DETAIL

R E

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

AutoCAD SHX Text A

AutoCAD SHX Text

A. DESIGN LOADS:

1. ROOF DEAD LOAD 30 PSF

2. ROOF LIVE LOAD

a. CONSTRUCTION AND MAINTENANCE 20 PSF

3. FLOOR LIVE LOAD

a. OFFICE 50 PSF

b. RESTROOMS 75 PSF

c. STORAGE 125 PSF

d. MECHANICAL ROOM 125 PSF

4. SNOW LOADS (UFC 3-310-01 AND ASCE 7-10)

a. BALANCED ROOF SNOW LOAD 23 PSF

b. UNBALANCED ROOF SNOW LOAD 35 PSF

c. EXPOSURE FACTOR Ce=1.0

d. THERMAL FACTOR Ct=1.0

e. IMPORTANCE FACTOR I=1.2

5. WIND LOADS (ASCE 7-10)

a. BASIC WIND SPEED V=120 MPH

b. EXPOSURE FACTOR C

c. RISK CATEGORY IV

6. SEISMIC LOADS (UFC 3-310-01 AND ASCE 7-10)

a. I=1.5 (RISK CATEGORY IV)

b. SS=0.09

c. S1=0.03

d. SITE CLASSIFICATION: D

e. SEISMIC DESIGN CATEGORY: A

B. FOUNDATION

1. ALLOWABLE EXCESS SOIL BEARING PRESSURE 3,000 PSF

2. GEOTECH REPORT: REPORT NO. 14-517-00058 PREPARED BY AMEC

ENVIRONMENT & INFRASTRUCTURE, INC. DATED DECEMBER 17, 2014

C. CAST IN PLACE CONCRETE AND REINFORCEMENT (ACI 318-11)

1. CAST-IN-PLACE CONCRETE EXPOSED TO FREEZE-THAW CYCLES

SHALL BE NORMAL WEIGHT CONCRETE WITH A MINIMUM COMPRESSIVE

STRENGTH OF 4,500 PSI AT 28 DAYS. ALL OTHER CAST-IN-PLACE

CONCRETE SHALL BE NORMAL WEIGHT CONCRETE WITH A MINIMUM

COMPRESSIVE STRENGTH OF 4,000 PSI AT 28 DAYS.

2. CEMENT: PORTLAND CEMENT PER ASTM C150

3. ALL REINFORCING STEEL SHALL BE ASTM A615, GRADE 60

4. LAP SPLICES SHALL CONFORM TO ACI 318-11 USING CLASS B TENSION

SPLICES UNLESS OTHERWISE NOTED. SEE TABLE, THIS SHEET.

TABLE NOTES:

1. LAP SPLICE LENGTH FOR REINFORCED CONCRETE.

2. MINIMUM UNLESS NOTED OTHERWISE.

3. NOT ALL BAR SIZES ARE INCLUDED IN PROJECT.

4. TOP BARS ARE HORIZONTAL BARS SO PLACED THAT MORE THAN 12"

OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE SPLICE

5. CONCRETE COVER SHALL CONFORM TO ACI 318-11

6. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185

D. STRUCTURAL STEEL

1. ALL STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL CONFORM

TO ASTM A992, GRADE 50. (FY=50 KSI)

2. ALL STRUCTURAL STEEL TUBE SHAPES SHALL CONFORM TO

ASTM A500, GRADE B. (FY=46 KSI)

3. ALL STRUCTURAL STEEL PIPES SHALL CONFORM TO ASTM A53,

GRADE B, SCH. 40. (FY=35 KSI)

4. ALL OTHER STRUCTURAL STEEL SHAPES SHALL CONFORM TO

ASTM A36. (FY=36 KSI)

5. ANCHOR RODS SHALL CONFORM TO FI554, GR. 36

6. BOLTED CONNECTIONS

a. ALL BOLTED CONNECTIONS SHALL BE A325N, SNUG TIGHTENED

7. WELDED HEADED ANCHOR STUDS (WELDED STUDS) SHALL CONFORM

TO ASTM A108

8. WELDING

a. WELDING ELECTRODES SHALL BE E70XX OR E60XX FOR STEEL

DECK ATTACHMENT. ALL OTHER WELDING SHALL USE E70XX

ELECTRODES.

b. WELDING SHALL CONFORM TO AWS D1.1

9. STRUCTURAL STEEL FRAMING SHALL BE ADEQUATELY BRACED BY

ERECTOR IN BOTH HORIZONTAL DIRECTIONS UNTIL STEEL ROOF DECK IS

IN FULLY ATTACHED POSITION.

E. STEEL DECK

1. STEEL ROOF DECK SHALL CONFORM TO THE STEEL DECK

INSTITUTE (SDI) SPECIFICATIONS FOR STEEL ROOF DECK,

PUBLICATION NO. 31, 2007. ROOF DECK SHALL BE GALVANIZED FINISH.

F. CONCRETE MASONRY

1. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C-90, TYPE I,

GRADE N-1 (F'M=1500 PSI)

2. MORTAR SHALL CONFORM TO ASTM C-270, TYPE S, AND HAVE A MINIMUM

28 DAY COMPRESSIVE STRENGTH OF 1800 PSI

3. GROUT SHALL CONFORM TO ASTM C-476 AND HAVE A MINIMUM 28 DAY

COMPRESSIVE STRENGTH OF 2000 PSI

4. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60

5. JOINT REINFORCEMENT SHALL BE PLACED @ 16" VERTICALLY UNLESS

OTHERWISE STATED

G. STEEL JOISTS

1. STEEL JOISTS SHALL CONFORM TO THE STANDARD SPECIFICATION AND

STANDARD LOAD TABLES FOR OPEN WEB STEEL JOISTS, K-SERIES OF THE

STEEL JOIST INSTITUTE (SJI).

2. JOIST BRIDGING SIZE AND SPACING SHALL BE DETERMINED BY JOIST

MANUFACTURER. ADDITIONAL BRIDGING REQUIRED FOR WIND UPLIFT SHALL BE ADDED

BY JOIST SUPPLIER. BRIDGING SHALL BE CROSS BRACED WHERE TERMINATING AT

ROLLED SECTIONS. SEE ROOF FRAMING PLANS.

3. SPECIAL JOISTS, DESIGNATED "SP", SHALL BE DESIGNED BY THE JOIST

MANUFACTURER FOR LOADS AND REQUIREMENTS SHOWN ON JOIST LOADING

DIAGRAMS. IF REQUIRED, LARGER JOISTS SHALL BE PROVIDED BYTHE CONTRACTOR

AT NO ADDITIONAL COST TO THE GOVERNMENT.

4. JOIST DEFLECTION SHALL BE LIMITED TO L/240 FOR COMBINED DEAD AND LIVE LOAD.

5. THE CONTRACTOR SHALL PROVIDE ANY ADDITIONAL MEMBERS REQUIRED TO

TRANSFER LOADS NOT APPLIED AT A PANEL POINT.

6. JOISTS SHALL BE ERECTED IN CONFORMANCE WITH MANUFACTURER'S INSTRUCTIONS,

STEEL JOIST INSTITUTE RECOMMENDATIONS AND APPLICABLE SAFETY AND HEALTH

REGULATIONS. ALL BRIDGING SHALL BE FULLY INSTALLED AND ANCHORED OR CROSS-

BRACED BEFORE ANY CONSTRUCTION LOADS ARE APPLIED.

GENERAL NOTES

1. REFERENCE ELEVATION 100'-0" DOES NOT EQUAL MEAN SEA ELEVATION

BAR SIZE NO. TOP BAR OTHER

LAP SPLICE LENGTH

#3 23" 18"

#4 31" 24"

#5 38" 30"

#6 46" 36"

#7 54" 42"

2. COORDINATION:

a. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE STARTING WORK.

b. CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE BRACING AND SHORING

AT ALL TIMES DURING CONSTRUCTION.

c. STRUCTURAL DRAWINGS SHALL BE COORDINATED WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL OPENINGS, SLEEVES, ETC. NOT

SHOWN ON STRUCTURAL DRAWINGS. COORDINATE LOCATION, SIZE, AND

REINFORCING OF ALL OPENINGS WITH RESPECTIVE TRADES BEFORE FABRICATION.

CORNER

BAR

CORNER BAR

CORNER BAR

NOTE:

1. DETAILS APPLY ALSO TO FOOTINGS & FOUNDATION WALLS.

2. CORNER BARS TO MATCH SIZE & SPACING OF HORIZONTAL BARS.

EXTRA #6

VERTICAL

BAR

S E

E

S

C H

E D

U L

E

SEE SCHEDULE

SEE SCHEDULE

EXTRA #5

VERTICAL

BAR

S E

E

S C

H E

D U

L E

EXTRA #5

VERTICAL

BAR

EXTRA #5

VERTICAL

BAR

SCALE: NO SCALE

TYPICAL LAP BAR DETAIL FOR HORIZONTAL CONCRETE REINFORCEMENT

3/8"

T

W H

I C

H E

V E

R

G

E

A T

E R

SAWCUT SEALANT

RESERVOIR

CENTERED ON SLAB

JOINT

3/8"

SAWCUT SEALANT

RESERVOIR

CENTERED ON SLAB

JOINT

SCALE: NO SCALE

DETAIL

A

SCALE: NO SCALE

DETAIL

B

NOTES:

1.) B.F. BOTTOM FACE

E.W. EACH WAY

2.)C.J. CONTRACTION JOINT

3.) AT CONTRACTORS OPTION CONSTRUCTION JOINT

MAY BE SUBSTITUTED FOR CONTRACTION JOINT

STOP SLAB REINF. 2"

FROM JOINT (TYP.)

3/4" DIA. SMOOTH DOWEL

16" LONG @ 12" O.C.

PAINTED & OILED ONE END

PER SPECIFICATIONS

(CENTERED IN SLAB)

HARDBOARD INSERT

OR 1/8" WIDE SAWCUT

STOP SLAB REINF. 2"

FROM JOINT (TYP.)

A

SB001A

B

SB001A

SCALE: NO SCALE

CONTRACTION JOINT IN SLAB

SCALE: NO SCALE

DOWELED CONSTR. JT. IN SLAB

CONCRETE SLAB

ON GRADE

FOUNDATION WALL

OR OTHER VERTICAL

SURFACE

NO. 30 FELT

3/8"

FORMED SEALANT

RESERVOIR

WITH SEALANT

SCALE: NO SCALE

SLAB ON GRADE AT VERTICAL SURFACE DETAIL

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

X

P R

O J E

D

E S

C

N T

S

SB001A

K

S

B

A D

W G

D E

S I G

N

A

G

N

E R

A L

N

O T

E S

K F

B

R E

D E

H O

E

P P

R

B U

I L D

I N

G

A

K

J

H

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

SCALE: 1/4" = 1'-0"

2' 4'0 8'

FOUNDATION PLAN NOTES:

1. FINISHED FLOOR ELEVATION = 100'-0". ARCHITECTURAL ELEVATION 100'-0"

EQUALS CIVIL ELEVATION 4281.00'.

2. ALL INTERIOR SLABS ON GRADE SHALL BE PLACED ON A VAPOR BARRIER

OVER A 6" CAPILLARY WATER BARRIER, U.N.O.

3. DETAILS INDICATED AS "TYPICAL" MAY NOT BE INDICATED ON PLAN. THESE

DETAILS APPLY IN AREAS WHERE A CONDITION SIMILAR TO THAT DEPICTED

IN THE DETAIL OCCURS.

4. FLOOR SLAB SUBGRADE AREAS SHALL BE OVEREXCAVATED TO SUCH AN

EXTENT SO AS TO PROVIDE A MINIMUM OF 12" OF STRUCTURAL FILL

BENEATH ALL FLOOR SLABS AND PAVEMENTS; HOWEVER, PROVIDED THAT

THE EXISTING SUBGRADE SOILS MEET THE PHYSICAL CHARACTERISTICS

FOR STRUCTURAL FILL, ONLY SCARIFICATION AND COMPACTION WILL BE

NECESSARY.

5. EXPOSED CUT SURFACES, AS WELL AS SURFACES TO RECEIVE FILL, SHALL

BE SCARIFIED TO A MINIMUM DEPTH OF 8 INCHES AND WATERED AS

NECESSARY TO BRING THE UPPER 12 INCHES TO OPTIMUM MOISTURE

CONTENT OR ABOVE.

6. PRIOR TO PLACEMENT OF FILL THE BUILDING AND PAVED AREAS SHALL BE

INSPECTED AND APPROVED BY A REPRESENTATIVE OF THE GEOTECHNICAL

ENGINEER.

7. FILL SHALL BE SPREAD IN LAYERS NOT EXCEEDING 8 INCHES, WATERED AS

NECESSARY, AND COMPACTED. MOISTURE CONTENT AT THE TIME OF

COMPACTION SHALL BE 2 PERCENT BELOW OPTIMUM MOISTURE OR

HIGHER. A DENSITY OF NOT LESS THAN 95% MAXIMUM DRY DENSITY WITHIN

THE BUILDING PAD AND PAVED AREAS SHALL BE OBTAINED FOR THE

STRUCTURAL FILL. STRUCTURAL FILL, AS WELL AS THE NATIVE SOILS,

OUTSIDE THE BUILDING PAD AND PAVED AREAS SHALL BE COMPACTED TO

90% OF MAXIMUM DRY DENSITY.

8. DIMENSIONS SHOWN AROUND BUILDING PERIMETER ARE TO FACE OF

CONCRETE FOOTING.

A

A

FOOTING SCHEDULE

MARK FOOTING BOTTOM OF

FOOTING

ELEVATION

SIZE REINFORCING

CF2-0

2'-0"x1'-4" (3) #5 LONG., BOTTOM 97'-10"

MASONRY SCHEDULE

MARK WIDTH REINFORCING

8" #5 BARS @ 24" O.C.MAX.

SCALE: 1/4 INCH = 1 FOOT

FOUNDATION PLAN

SB501A

SB501A

CF2-0

CF2-0

C F

C F

A

STRUCTURAL STOOP

STRUCTURAL

STOOP

C J

C J

44'-0 3/8"

4'-0" TYP.

F1 3'-0"x3'-0"x1'-0" (3) #5 E.W., BOTTOM 98'-4"

HSS4X4X5/16

C J

C.J.

F1

16'-8 3/8"

SB501A

SB501A

SB501A

TRUE

NORTH

PLAN

NORTH

STRUCTURAL STOOP

C.J.

C.J.

C.J.

A

4" CONC. SLAB ON GRADE

W/ 6X6 W2.9XW2.9 W.W.F.

SB501A

FLOOR DRAIN

- SEE MECH.

FLOOR DRAIN

- SEE MECH.

FLOOR DRAIN

- SEE MECH.

SB501A

SB501A

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

X

P R

O J E

D

E S

C

SB101A

K

S

B

A D

W G

F O

U N

D A

T I O

N

P

L A

N

K F

B

R E

D E

H O

E

P P

R

B U

I L D

I N

G

A

K

A D

Y

T

O

A

D V

E R

T I S

E

R

T A

SCALE: 3/4" = 1'-0"

8" 1'-4"0 2'-8"

S E

E

P

L A

N

S E

E

P

L A

N

6"

6"

20"

SCALE: 3/4 INCH = 1 FOOT

TYPICAL STRUCTURAL CONCRETE STOOP DETAIL

SCALE: 3/4 INCH = 1 FOOT

EXTERIOR WALL AT CONCRETE FOOTING

1/2 WALL HT.

(APPROX.)

24" 3"

3"

NOTE:

ALSO APPLICABLE TO

WALL CORNERS

DETAILS I, II, OR III

AT CONTRACTOR'S

OPTION

I

II

III

OVERLAPPING

COURSES

SPECIFIED JOINT REINF.

@ 16" O.C. VERT.

FILL W/ GROUT

CONTROL JOINT

LOCATION - REF.

ARCH. PLANS

NON-OVERLAPPING

COURSES

SPECIFIED JOINT REINF.

@ 16" O.C. VERT.

STEEL STRAP 1/4"x1"x

@ 32" O.C.

SCALE: 3/4 INCH = 1 FOOT

TYPICAL MASONRY WALL INTERSECTION DETAILS

#3 @ 24" O.C.

1/2" EXPANSION JOINT

6" CONCRETE SLAB

W/ #4 @ 12" O.C.

EACH WAY

WALL BEYOND

- SEE PLAN

CONC. SLAB ON GRADE

- SEE PLAN

VAPOR BARRIER

CONC. FTG. - SEE

PLAN & SCHED. FOR

SIZE & REINF.

PAVING -

SEE CIVIL

CMU WALL

- SEE PLAN

1/2" EXPANSION JOINT

CONC. SLAB ON GRADE

- SEE PLAN

VAPOR BARRIER

CONC. FTG. - SEE

PLAN & SCHED. FOR

SIZE & REINF.

CMU VENEER

- SEE ARCH.

PROVIDE DOWEL TO

MATCH AND LAP

VERT. WALL REINF.

GROUT SOLID

BELOW GRADE

CENTERLINE OF CMU

WALL = CENTERLINE

OF FOOTING

FINISH GRADE

OR CONC. SLAB

AS OCCURS

LEAN CONCRETE FILL

TO MATCH DEPTH OF

ADJACENT FOOTING

10"X10"X3/4" BASE PLATE OVER 1 1/2"

NON-SHRINK GROUT W/ (4) 3/4" Ø

ANCHOR BOLTS (8" EMBED.)

CONCRETE CLOSURE POUR

AROUND BASE PLATE CONNECTION

1/2" EXPANSION JOINT

CONC. SLAB ON

GRADE - SEE PLAN

CONC. FTG. - SEE

PLAN & SCHED. FOR

SIZE & REINF.

VAPOR BARRIER

STEEL COLUMN - SEE PLAN

1/4

SCALE: 3/4 INCH = 1 FOOT

STEEL COLUMN AT CONCRETE PAD FOOTING

S E

E

P

L A

N

SCALE: 3/4 INCH = 1 FOOT

EXTERIOR WALL AT CONCRETE FOOTING

CMU WALL

- SEE PLAN

CONC. FTG. - SEE

PLAN & SCHED. FOR

SIZE & REINF.

CMU VENEER

- SEE ARCH.

PROVIDE DOWEL TO

MATCH AND LAP

VERT. WALL REINF.

GROUT SOLID

BELOW GRADE

CENTERLINE OF CMU

WALL = CENTERLINE

OF FOOTING

FINISH GRADE

OR CONC. SLAB

AS OCCURS

CENTERLINE OF COLUMN =

CENTERLINE OF FOOTING

8" TYP.

8"

S E

E

P L A

N

S E

E

P L A

N

B

M

I N

B

(FTG. WIDTH)

2/3 B

(3'-0" MIN.)

STRUCTURAL

CONCRETE FOOTING

EXISTING SOILS TO BE

REPLACED WITH STRUCTURAL

FILL TO EXTENTS SHOWN

EXCAVATION LINE IN

COMPLIANCE WITH

OSHA STANDARDS

UNDISTURBED SOIL

SCALE: NONE

STRUCTURAL FILL REQUIREMENTS BELOW FOOTINGS

S O

L I C

I T

A T

I O

N

N

O

F I

M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

D A

T E

F I

M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

D A

T E

U

S

A

R M

Y

E

N G

I N

E E

R

D

I S

T R

I C

T

C O

R P

S

O

F

E

N G

I N

E E

R S

C O

N T

R A

OMAHA DISTRICT

O M

A H

A

N

E B

R A

S K

A

C O

N S

T R

U C

T

P

U M

P H

O U

E

L

S

T O

R A

G E

C A

N N

B

N

X

I C

O

X

P R

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .